## WLB32 Industrial LED Light Bar (DC) Instruction Manual **==> picture [464 x 368] intentionally omitted <==** Original Instructions p/n: 176313 Rev. L 26-Nov-24 © Banner Engineering Corp. All rights reserved. ## Contents **Chapter 1 Features and Models............................................................................................. 3 Chapter 2 WLB32 (DC) Wiring................................................................................................ 5 Chapter 3 WLB32 (DC) Specifications** FCC Part 15 Class B for Unintentional Radiators.......................................................................................................................................... 7 Industry Canada ICES-003(B)....................................................................................................................................................................... 7 WLB32 Dimensions....................................................................................................................................................................................... 8 Spacing Criteria (SC)..................................................................................................................................................................................... 8 WLB Light Characteristics ............................................................................................................................................................................. 9 **Chapter 4 Accessories** Cordsets ...................................................................................................................................................................................................... 12 Enclosure Accessories ................................................................................................................................................................................ 14 Brackets....................................................................................................................................................................................................... 14 **Chapter 5 Product Support and Maintenance** Banner Engineering Corp Limited Warranty................................................................................................................................................ 15 Mexican Importer......................................................................................................................................................................................... 15 Document Information ................................................................................................................................................................................. 15 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual ## Chapter Contents ## Chapter 1 ## Features and Models Banner’s WLB32 is an ultra-bright LED fixture that features an even light output for a no-glare ‘glow’. Suitable for a variety of environments and applications, including workstations, machine lighting, control cabinets, and manufacturing lines, the WLB32 uses advanced LED lighting technology to provide a high-quality and maintenance-free industrial lighting solution for years. - Highly energy efficient for overall cost savings - • High/Low/Off switch • Models with eye shield block side glare • Connect power in sequence to multiple lights • Motion detection models available • Metal housing, shatterproof window • Easy installation with snap clips, or a choice of magnetic or angle brackets Model without angle brackets Motion Detector Model with Model with Eye WLB32 Industrial LED Light Bars are available in models that can Motion Detector Shield and be connected in sequence together for a continuous length of Motion Detector lighting, with a minimum of wiring. Each light bar can be turned to high, low, or off independently of the other lights, upstream or downstream, in the chain of lights. A double-ended accessory cordset must be used between each pair of connecting lights. **==> picture [500 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> 12 V DC to 30 V DC Models<br>Models Lighted Length (mm) Connector Lumens<br>WLB32C285PBQ 285 750<br>WLB32C570PBQ 570 1500<br>Integral 4-pin M12 quick-disconnect<br>connector<br>WLB32C850PBQ 850 2250<br>WLB32C1130PBQ 1130 3000<br>WLB32C285PB 285 750<br>WLB32C570PB 570 1500<br>2 m (6.5 ft) cable<br>WLB32C850PB 850 2250<br>WLB32C1130PB 1130 3000<br>**----- End of picture text -----**<br> - To order the light without the integral switch, omit the "PB" from the model number. For example, WLB32C285Q. - To order the light with the integral motion detector, replace the 'PB' from the model number with 'M'. For example, WLB32C285MQ. - To order the light with the eye shield, add an 'E' after the length. For example, WLB32C285EPBQ. IMPORTANT: Read the following instructions before operating the light. Please download the complete WLB32 Industrial Light Bar (DC) technical documentation, available in multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions of this device. IMPORTANT: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde www.bannerengineering.com toda la documentación técnica de los WLB32 Industrial Light Bar (DC), disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las instrucciones de instalación de estos dispositivos. page 3 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual Features and Models IMPORTANT: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation technique complète des WLB32 Industrial Light Bar (DC) sur notre site www.bannerengineering.com pour les détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage. page 4 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual ## Chapter Contents ## Chapter 2 ## WLB32 (DC) Wiring **==> picture [500 x 175] intentionally omitted <==** **----- Start of picture text -----**<br> Wiring Pinouts (Female and Male) Wiring Key<br>bn (1) Female<br>+<br>Switch Models bu (3) 12–30 V DC– 1 2 1 = Brown3 = Blue<br>3<br>4<br>Male<br>bn (1) + 1 = Brown, connect for 100% intensity3 = Blue<br>Non-Switch 12–30 V DC 1 4 = Black*<br>and Motion bu (3) – 2 * For models without motion detection, connect the<br>Detector 4 black wire to 12 to 30 V DC for 50% maximum<br>Models bk (4) + 3 intensity. For models with motion detection, connect<br>the black wire to 12 to 30 V DC to bypass the motion<br>detector switch.<br>**----- End of picture text -----**<br> page 5 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual ## Chapter Contents FCC Part 15 Class B for Unintentional Radiators ................................................................................................................................................ 7 Industry Canada ICES-003(B).............................................................................................................................................................................. 7 WLB32 Dimensions.............................................................................................................................................................................................. 8 Spacing Criteria (SC) ........................................................................................................................................................................................... 8 WLB Light Characteristics.................................................................................................................................................................................... 9 ## Chapter 3 ## WLB32 (DC) Specifications ## Supply Voltage ## 12 V DC to 30 V DC Use only with a suitable Class 2 power supply (UL) or SELV power supply (CE) See electrical characteristics on product label ## Supply Protection Circuitry Protected against reverse polarity and transient voltages ## LED Lifetime Lumen Maintenance - L70 When operating within specifications, output will decrease less than 30% after 70,000 hours. ## Supply Current **==> picture [221 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> Maximum Typical Current Draw (A)<br>Light Length<br>Current Draw<br>(mm) (A) 12 V DC 24 V DC 30 V DC<br>285 0.55 0.45 0.23 0.19<br>570 1.1 0.90 0.44 0.36<br>850 1.6 1.36 0.65 0.54<br>1130 2.2 1.8 0.84 0.68<br>**----- End of picture text -----**<br> ## Light Characteristics Color: Daylight white Color temperature (CCT): 5000K (±300K) Lumen output: 750 (±5%) per foot, typical at 25 °C (77 °F) Luminous efficacy: 140 lumens/Watt typical at 24 V DC at 25 °C (77 °F) CRI: 82, typical Eye shield reduces lumens by about 25% Push Button II = 100% light intensity I = 50% light intensity O = Off ## Connections Integral 4-pin M12 quick-disconnect connector (4-pin connecting cordset required for quick-disconnect models); or 2 m (6.5 ft) integral cable Environmental Rating IP50 ## Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) ## Operating Temperature –40 °C to +70 °C (–40 °F to +158 °F) Light output begins to decrease above 50 °C (122 °F) and will be approximately 65% of max intensity at 60 °C (140 °F) and 30% of max intensity at 70 °C (158 °F) Models with motion detection: –20 °C to +60 °C (–4 °F to +140 °F) ## Storage Temperature –40 °C to +70 °C (–40 °F to +158 °F) Test Data LM-79, LM-80, TM-21 Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN E476617 UL Recognized for easy installation in control cabinets. Models with Motion Detection Light turns off after approximately 60 seconds without detecting motion. Range: 12 meters; ±45° field of view Standby current: 170 µA ## Construction Anodized aluminum housing; polycarbonate window and end caps; stainless steel mounting brackets Spacing Criterion Vertical: 1.22 Horizontal: 1.32 Mounting Snap clips; optional magnetic mount or swivel bracket accessories available page 6 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 (DC) Specifications WLB32 Industrial LED Light Bar (DC) Instruction Manual ## Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. |Supply<br>Wiring<br>(AWG)<br>20|Required Overcurrent<br>Protection (A)<br>5.0|Required Overcurrent<br>Protection (A)<br>5.0|Supply<br>Wiring<br>(AWG)<br>26|Required Overcurrent<br>Protection (A)<br>1.0|Required Overcurrent<br>Protection (A)<br>1.0| |---|---|---|---|---|---| |22|3.0||28|0.8|| |24|1.0||30|0.5|| ## Application Note When connecting cascadable lights in series it is important not to exceed the maximum current limitation of 4 Amps Maximum length of light at 12 V DC: 2 m (6.6 ft) Maximum length of light at 24 V DC: 4.8 m (15.7 ft) Maximum length of light at 30 V DC: 5.9 m (19.4 ft) ## FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. page 7 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual WLB32 (DC) Specifications ## WLB32 Dimensions **==> picture [11 x 38] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>L2<br>**----- End of picture text -----**<br> ## Motion Detector and/or Eye Shield Models Specific to models with shield **==> picture [500 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> Models without Motion Detector Models with Motion Detector and/or Eye Shields<br>Models<br>L1 L2 L3 L4<br>WLB32C285..Q 298 mm (11.7 in) 320 mm (12.6 in) 368 mm (14.5 in) 390 mm (15.4 in)<br>WLB32C570..Q 580 mm (22.8 in) 602 mm (23.7 in) 650 mm (25.6 in) 672 mm (26.5 in)<br>WLB32C850..Q 862 mm (33.9 in) 884 mm (34.8 in) 932 mm (36.7 in) 954 mm (37.6 in)<br>WLB32C1130..Q 1144 mm (45.0 in) 1166 mm (45.9 in) 1214 mm (47.8 in) 1236 mm (48.7 in)<br>WLB32C285.. 298 mm (11.7 in) 313 mm (12.3 in) 368 mm (14.5 in) 383 mm (15.1 in)<br>WLB32C570.. 580 mm (22.8 in) 595 mm (23.4 in) 650 mm (25.6 in) 665 mm (26.2 in)<br>WLB32C850.. 862 mm (33.9 in) 877 mm (34.5 in) 932 mm (36.7 in) 947 mm (37.3 in)<br>WLB32C1130.. 1144 mm (45.0 in) 1159 mm (45.6 in) 1214 mm (47.8 in) 1229 mm (48.4 in)<br>**----- End of picture text -----**<br> ## Spacing Criteria (SC) The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between fixtures). Luminaire Spacing = SC × Height to Illuminated Plane The mounting height is the distance from the fixture to the surface you are lighting. page 8 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 (DC) Specifications WLB32 Industrial LED Light Bar (DC) Instruction Manual ## WLB Light Characteristics **==> picture [469 x 187] intentionally omitted <==** **----- Start of picture text -----**<br> 285 mm Models<br>Illuminance at a Distance Isolux Pattern Polar Candela Distribution<br>2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 230 170°160°150°<br>0.17 m 3682 lux 0.4 m 0.7 m 192153 LTT 140°130°<br>0.33 m 1979 lux 0.8 m 1.4 m 1 115 120°<br>0.50 m 825 lux 1.2 m 2.1 m 77 110°<br>0.67 m = 439 lux 1.6 m S 2.8 m 38 LTOes 100°<br>0.83 m 345 lux 2.0 m 3.5 m 0 m 0 90°<br>223 lux 2.4 m 4.2 m 38 80°<br>1.00 m<br>ESS Vert. Horiz. 77 SoONED 70°<br>== 115 [NR 60°<br>Vertical Spread: 101.5° 1 153 50°<br>Horizontal Spread: 128.8° 192 40°<br>230 Vertical Angle: 0° 10° 20° 30°<br>2<br>Mount height of 1 meter (1 m) Oo 0° Vertical ni 90° Horizontal<br>150 lux |_| 75 lux |_| 10 lux<br>125 lux |_| 50 lux |_| 5 lux<br>100 lux 25 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> **==> picture [469 x 399] intentionally omitted <==** **----- Start of picture text -----**<br> 570 mm Models<br>Illuminance at a Distance Isolux Pattern Polar Candela Distribution<br>2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 460 170°160°150°<br>0.17 m0.33 m 4721 lux2937 lux 0.4 m0.8 m 0.7 m1.4 m 1 383307230 LTTes7 140°130°120°<br>0.50 m 1359 lux 1.2 m 2.1 m 153 Teese 110°<br>0.67 m 785 lux 1.6 m 2.7 m 77 HE 100°<br>0.83 m 621 lux 2.0 m 3.4 m 0 m 0 90°<br>1.00 m 451 lux 4S 2.4 mVert. 4.1 mHoriz. ___ 15377 SNE 70°80°<br>7Na Vertical Spread: 101.5°Horizontal Spread: 128.2° — 1 230307383 [NRHRY 40°50°60°<br>460 Vertical Angle: Ny 0° 10° 20° ee 30°<br>2<br>Mount height of 1 meter (1 m) oO 0° Vertical mi 90° Horizontal<br>300 lux |_| 150 lux |_| 25 lux<br>250 lux |_| 100 lux |_| 10 lux<br>200 lux 50 lux<br>850 mm Models<br>Illuminance at a Distance Isolux Pattern Polar Candela Distribution<br>2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 650 170°160°150°<br>5371 lux 0.4 m 0.7 m 542 140°<br>0.17 m0.33 m 3470 lux 0.8 m 1.4 m 1 433325 LTTLAO 130°120°<br>0.50 m 1831 lux 1.3 m 2.1 m 217 ese 110°<br>0.67 m 1103 lux 1.7 m 2.9 m 108 100°<br>0.83 m 899 lux 2.1 m 3.6 m 0 m 0 90°<br>1.00 m —_——FEE 647 lux a—= 2.5 mVert. 4.3 mHoriz. 108217 SfprceeeeWeeNET 70°80°<br>IN Vertical Spread: 102.7° 1 325433 (Ne 50°60°<br>Horizontal Spread: 130.1° 542 RY 40°<br>650 Vertical Angle: 0° 10° 20° 30°<br>2<br>Mount height of 1 meter (1 m) Oo 0° Vertical ni 90° Horizontal<br>450 lux |_| 225 lux |_| 25 lux<br>375 lux |_| 150 lux |_| 10 lux Illuminance at a Distance<br>300 lux 75 lux<br>CD<br>(candela)<br>CD<br>(candela)<br>**----- End of picture text -----**<br> page 9 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual WLB32 (DC) Specifications ## 1130 mm Models ## Illuminance at a Distance Isolux Pattern Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 870 170°160°150°<br>5371 lux 0.4 m 0.7 m 725 140°<br>0.17 m0.33 m 3639 lux 0.8 m 1.4 m 1 580435 TLS 130°120°<br>0.50 m 2008 lux 1.3 m 2.1 m 290 LIXyee. 110°<br>0.67 m 1274 lux 1.7 m 2.9 m 145 100°<br>0.83 m 1065 lux 2.1 m 3.6 m 0 m 0 90°<br>1.00 m 869 lux 2.5 m 4.3 m 145 ra == 80°<br>Vert. Horiz. 290 70°<br>Vertical Spread: 103.3° 1 435580 50°60°<br>Horizontal Spread: 129.7° 725 40°<br>870 Vertical Angle: 0° 10° 20° 30°<br>2 Mount height of 1 meter (1 m) oO 0° Vertical ni 90° Horizontal<br>600 lux == 300 lux 50 lux<br>500 lux = 200 lux m7 25 lux<br>400 lux 100 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> ## Illuminance at a Distance 285 mm Models with Eye Shields Isolux Pattern Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 250 170°160°150°<br>3654 lux 0.4 m 0.4 m 208 = 140°<br>0.17 m0.33 m 2024 lux 0.8 m 0.8 m 1 167125 130°120°<br>0.50 m 813 lux 1.2 m 1.3 m 83 110°<br>0.67 m —-_— 442 lux 1.6 m 1.7 m 42 TDWine 100°<br>0.83 m1.00 m ooo 345 lux250 lux 2.0 m2.3 m 2.1 m2.5 m 0 m 420 yy> Ty] 80°90°<br>Vert. Horiz. 83 70°<br>“ Vertical Spread: 98.7° —- 1 125167 PASS 50°60°<br>A Horizontal Spread: 102.8° 208 Se 40°<br>250 Vertical Angle: —_ 0° 10° zy 20° 30°<br>2<br>Mount height of 1 meter (1 m) oO 0° Vertical ni 90° Horizontal<br>150 lux a 75 lux a 10 lux<br>125 lux 50 lux 5 lux<br>m7 a<br>100 lux 25 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> 570 mm Models with Eye Shields Illuminance at a Distance Isolux Pattern Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 500 . 170°160°150°<br>5334 lux 0.3 m 0.4 m 417 140°<br>0.17 m0.33 m 3313 lux 0.6 m 0.8 m 1 333250 ahBOD 130°120°<br>0.50 m 1595 lux 0.9 m 1.1 m 167 TIS 110°<br>0.67 m —_— 884 lux 1.2 m 1.5 m 83 rox> 100°<br>0.83 m 706 lux 1.5 m 1.9 m 0 m 0 90°<br>1.00 m 484 lux 1.8 m 2.3 m 83 80°<br>ESS Vert. Horiz. 167 :TF>SKROTSe 70°<br>~ Vertical Spread: 83.5° 1 250333 50°60°<br>Horizontal Spread: 97.0° 417 40°<br>A == 500 Vertical Angle: [\& 0° 10° 20° 30°<br>2<br>Mount height of 1 meter (1 m) im 0° Vertical ni 90° Horizontal<br>300 lux a 150 lux = 25 lux<br>250 lux 100 lux 10 lux<br>m7 a<br>200 lux 50 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> page 10 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 (DC) Specifications WLB32 Industrial LED Light Bar (DC) Instruction Manual Illuminance at a Distance 850 mm Models with Eye Shields Isolux Pattern Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 630 170°160°150°<br>5533 lux 0.3 m 0.5 m 525 140°<br>0.17 m0.33 m 3460 lux 0.6 m 1.0 m 1 420315 130°120°<br>0.50 m 1815 lux 0.9 m 1.6 m 210 TES 110°<br>0.67 m 1096 lux 1.2 m 2.1 m 105 100°<br>0.83 m 896 lux 1.4 m 2.6 m 0 m 0 90°<br>1.00 m 623 lux 1.7 m 3.1 m 105 80°<br>Vert. Horiz. 210 70°<br>_,a Vertical Spread: 81.4° oeoe 1 315420 2 +f | aan\\ wa L 50° 7 60° |<br>A Horizontal Spread: 114.2° 525 40°<br>630 Vertical Angle: 0° 10° 20° 30°<br>2<br>Mount height of 1 meter (1 m) 0° Vertical i 90° Horizontal<br>450 lux a 225 lux a 25 lux<br>375 lux300 lux ml 150 lux75 lux a 10 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> Illuminance at a Distance 1130 mm Models with Eye Shields Isolux Pattern Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 820 170°160°150°<br>5733 lux 0.3 m 0.6 m 683 + 140°<br>0.17 m0.33 m 3904 lux 0.6 m 1.3 m 1 547410 TI 130°120°<br>0.50 m 2203 lux 0.9 m 1.9 m 273 Hieee 110°<br>0.67 m 1390 lux 1.2 m 2.6 m 137 LOS 100°<br>0.83 m 1139 lux 1.5 m 3.2 m 0 m 0 90°<br>1.00 m 806 lux 1.8 m 3.8 m 137 80°<br>Vert. Horiz. 273 70°<br>Vertical Spread: 83.8° 1 410547 50°60°<br>‘ Horizontal Spread: 124.8° 683 if bo 40°<br>; 820 Vertical Angle: Ee 0° 10° ee 20° 30°<br>2<br>Mount height of 1 meter (1 m) o 0° Vertical i 90° Horizontal<br>600 lux a 300 lux a 50 lux<br>500 lux400 lux La 200 lux100 lux a 25 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> page 11 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual ## Chapter Contents |Cordsets ............................................................................................................................................................................................................. 12| |---| |Enclosure Accessories ....................................................................................................................................................................................... 14| |Brackets ............................................................................................................................................................................................................. 14| |Accessories<br>Chapter 4| ## Cordsets **==> picture [500 x 278] intentionally omitted <==** **----- Start of picture text -----**<br> 4-Pin Single-Ended M12 Female Cordsets<br>Model Length Style Dimensions Pinout (Female)<br>MQDC-406 2 m (6.56 ft) 44 Typ.<br>MQDC-415 5 m (16.4 ft)<br>2<br>MQDC-430 9 m (29.5 ft) 1<br>M12 x 1<br>Straight ø 14.5 3<br>Ø5.2 mm 4 5<br>MQDC-450 15 m (49.2 ft)<br>7 mm<br>58 mm 1 = Brown<br>2 = White<br>3 = Blue<br>MQDC-406RA 2 m (6.56 ft) 32 Typ. 4 = Black<br>[1.26"] 5 = Unused<br>MQDC-415RA 5 m (16.4 ft)<br>MQDC-430RA 9 m (29.5 ft) 30 Typ. 2<br>3<br>[1.18"]<br>1<br>Right-Angle 4<br>M12 x 1<br>ø 14.5 [0.57"]<br>MQDC-450RA 15 m (49.2 ft) Ø5.2 mm<br>7 mm<br>58 mm<br>**----- End of picture text -----**<br> page 12 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual Accessories **==> picture [479 x 627] intentionally omitted <==** **----- Start of picture text -----**<br> 4-Pin Double-Ended M12 Female to M12 Male Cordsets<br>Model Length Style Dimensions Pinout<br>MQDEC-401SS 0.31 m (1 ft)<br>40 Typ.<br>MQDEC-403SS 0.91 m (2.99 ft) [1.58"]<br>MQDEC-406SS 1.83 m (6 ft)<br>M12 x 1<br>MQDEC-412SS 3.66 m (12 ft) aa ø 14.5 [0.57"]<br>Male Straight / Female<br>MQDEC-415SS 4.58 m (15 ft) Straight 44 Typ.<br>[1.73"]<br>MQDEC-420SS 6.10 m (20 ft) Female<br>MQDEC-430SS 9.14 m (30.2 ft) M12 x 1 2<br>ori ø 14.5 [0.57"] . 1<br>MQDEC-450SS 15.2 m (49.9 ft) 3<br>4<br>MQDEC-403RS 0.91 m (2.99 ft)<br>MQDEC-406RSMQDEC-412RS 1.83 m (6 ft) 3.66 m (12 ft) ae 32 Typ.[1.26"] 30 Typ. Male<br>MQDEC-420RS 6.10 m (20 ft) [1.18"] 1<br>MQDEC-430RS 9.14 m (30.2 ft) Male Right-Angle / Female Straight ø 14.5 [0.57"]M12 x 1 mt 2 l= 4<br>ø 14.5 [0.57"] 3<br>44 Typ. M12 x 1 1 = Brown<br>MQDEC-450RS 15.2 m (49.9 ft) [1.73"] 2 = White<br>3 = Blue<br>4 = Black<br>MQDEC-403RR 0.9 m (2.9 ft) 32 Typ.<br>[1.26"]<br>MQDEC-406RR 1.8 m (5.9 ft)<br>30 Typ.<br>MQDEC-412RR 3.6 m (11.8 ft) [1.18"]<br>Male Right-Angle / Female Right-Angle ø 14.5 [0.57"]M12 x 1<br>31 Typ.<br>MQDEC-420RR 6.1 m (20 ft)<br>[ 32 Typ. ef<br>4-Pin Flat Junction M12 Female Branch to M12 MaleTrunk Splitter Cordsets<br>Model Branches (Female) Trunk (Male) Pinout<br>CSB-M1240M1240 No branch No trunk<br>CSB-M1240M1241 No trunk<br>CSB-M1241M1241 0.31 m (1 ft) Female<br>CSB-M1248M1241 2.44 m (8 ft) 2<br>2 × 0.3 m (1 ft) 1<br>CSB-M12415M1241 4.57 m (15 ft) 3<br>4<br>CSB-M12425M1241 7.60 m (25 ft)<br>CSB-UNT425M1241 7.60 m (25 ft) Unterminated<br>Male<br>CSB-M1243M1243 2 × 1 m (3.28 ft) 1 m (3.28 ft) 1<br>2 —_<br>Ø4.5 18.0 44 Typ. 4<br>40 Typ. [0.18"] [0.71"] [1.73"] 3<br>[1.58"]<br>Ø14.5 [0.57"] 1 = Brown<br>2 = White<br>Ø14.5 [0.57"]<br>M12 x 1 3 = Blue<br>4 = Black<br>M12 x 1 Mun+a<br>35 [1.38"] 43.0 ir=o<br>[1.69"]<br>**----- End of picture text -----**<br> page 13 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual Accessories ## Enclosure Accessories ## LMBEDS Switch - Bracket with plunger switch to power lights when the enclosure is opened - • Refer to datasheet 160672 for more information ## Brackets **==> picture [426 x 187] intentionally omitted <==** **----- Start of picture text -----**<br> 20 12<br>• Replaces the bracket that ships with the WLB32 light<br>• Stainless steel 36<br>• Includes 4 snap clips, 4 screws, and 2 insulator caps 2X Ø6.5<br>42 20<br>• Swivel bracket kit allows 180° of movement<br>36<br>Ø6.4<br>**----- End of picture text -----**<br> ## LMBWLB32 ## LMBWLB32-180S ## LMBWLB32MAG - Magnetic mounting bracket for easy attachment to steel and iron surfaces ## LMBWLB32U - Die-cast bracket for rugged applications - • Secured to light with included thumb screw • Clearance hole for 6 mm (1/4 in) button head screw ## LMBWLB32UT - Die-cast bracket for rugged applications - • Secured to light with included thumb screw • Integral 1/4-20 stud for mounting **==> picture [72 x 253] intentionally omitted <==** **----- Start of picture text -----**<br> 20 19<br>36<br>Ø36<br>41<br>18<br>20<br>41<br>18<br>20<br>27<br>**----- End of picture text -----**<br> page 14 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. WLB32 Industrial LED Light Bar (DC) Instruction Manual ## Chapter Contents Banner Engineering Corp Limited Warranty....................................................................................................................................................... 15 Mexican Importer................................................................................................................................................................................................ 15 Document Information........................................................................................................................................................................................ 15 ## Chapter 5 Product Support and Maintenance ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. ## Mexican Importer Banner Engineering de Mèxico, S. de R.L. de C.V. | David Alfaro Siqueiros 103 Piso 2 Valle oriente | San Pedro Garza Garcia Nuevo Leòn, C. P. 66269 81 8363.2714 ## Document Information Document title: WLB32 Industrial Light Bar (DC) Part number: 176313 Revision: L Original Instructions © Banner Engineering Corp. All rights reserved. page 15 of 16 26-Nov-24 © Banner Engineering Corp. All rights reserved. ## LinkedIn ## X (formerly Twitter) ## Facebook © 2024. All rights reserved. www.bannerengineering.com
Updated at April 28, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →