Image not available
Illustrative purposes only
VPU-S200-36
OPEN FRAME AC-DC CONVERTERS POWER SUPPLY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: VPU-S200 Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 201.79 € |
| Current stock | 100+ |
| Lead time | 30 days |
Additional Resources: Product Page ~~oe~~ **date** 01/08/2014 **page** 1 of 5 ## **SERIES:** VPU-S200 **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - up to 200 W continuous power - U-Frame |**MODEL**<br>**output**<br>**voltage**<br>**output**<br>**current**<br>**output**<br>**power**<br>**ripple and**<br>**noise**<br>**effi ciency**<br>(Vdc)<br>**max**<br>**(A)**<br>**max**<br>**(W**)<br>**max**<br>(mVp-p)<br>**typ**<br>(%)<br>VPU-S200-3.3<br>3.3<br>**30**<br>73<br>60<br>75<br>VPU-S200-5<br>5<br>**30**<br>150<br>60<br>75<br>VPU-S200-12<br>12<br>**16.7**<br>200<br>120<br>75<br>VPU-S200-15<br>1**5**<br>**13.3**<br>200<br>150<br>78<br>VPU-S200-24<br>**24**<br>**8.3**<br>200<br>240<br>81<br>VPU-S200-36<br>**36**<br>**5.**5<br>200<br>360<br>81<br>VPU-S200-48<br>**48**<br>4.2<br>200<br>480<br>81<br>• universal input (85-264 Vac / 120-340 Vdc)<br>• 12V fan drive<br>• single output from 3.3 to 48 V<br>• active power correction<br>• remote on/off<br>• power good signal<br>• remote sense<br>• short circuit, over voltage, over load, and over current protections<br>• UL/cUL and TUV safety approvals<br>• efficiency up to 81%<br>**DISCONT**INUE**D**<br>4<—AZ Z ! )<br>eeJ<br>HousWALsC€| |---| - universal input (85-264 Vac / 120-340 Vdc) - 12V fan drive - single output from 3.3 to 48 V - active power correction - remote on/off - power good signal - remote sense - short circuit, over voltage, over load, and over current protections - UL/cUL and TUV safety approvals - efficiency up to 81% **PART NUMBER KEY** ## **VPU-S200 - XX - X** **==> picture [215 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> Base Number Output Voltage Power Fail Detect<br>“Blank” = No<br>P = Yes<br>**----- End of picture text -----**<br> **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VPU-S200 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 01/08/2014 **│ page** 2 of 5 ## **INPUT** |**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>voltage<br>85<br>120<br>264<br>34**0**<br>**Va**~~**c**~~<br>**Vdc**<br>frequency<br>47<br>**63**<br>**Hz**<br>current<br>at 115 Vac, full load<br>at 230 Vac, full load<br>**1.4**<br>**0.7**<br>**A**<br>**A**<br>inrush current<br>at 115 Vac, 25°C, full load, cold start<br>at 230 Vac, 25°C, full load, cold start<br>**20**<br>**40**<br>**A**<br>**A**<br>power factor<br>at 100 Vac, full load<br>at 200 Vac, full load<br>**.99**<br>**.95**<br>**OUTPUT**<br>**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>line regulation<br>full load<br>**0.5**<br>1<br>%<br>load regulation<br>at 230 Vac<br>**3**<br>5<br>%<br>temperature coeff cient<br>all output<br>**±0**.05<br>%/°C<br>transient response<br>full load to half load at 100 Vac<br>4<br>ms<br>adjustability<br>Adjustable with built-in trim pot<br>±10<br>%<br>switching frequency<br>100<br>KHz<br>start-up time<br>full load at 100 Vac<br>0.5<br>s<br>hold-up time<br>full load at 110 Vac<br>20<br>ms<br>**PROTECTIONS**<br>**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>overload protection<br>recovers aut**omaticl**~~**y**~~<br>105<br>%<br>over voltage protection<br>115<br>140<br>%<br>short circuit protection<br>Prote**cted, long term short circuit**may reduce reliability<br>over current protection<br>r**ecovers automaticly**<br>105<br>%<br>**SAFETY & COMPLIANCE**<br>**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>isolation voltage<br>**Primary to secon**dary:<br>**Primary to tran**sformer core:<br>**Primary to e**arth ground:<br>4242<br>2000<br>2000<br>Vdc<br>Vac<br>Vac<br>isolation resist**ance**<br>**test volta**ge of 500 Vdc<br>50<br>MΩ<br>safety app**rovals**<br>**UL/cU**L 60950, TUV EN60950, CE, CB<br>EMI/E**MC**<br>**FC**C class B, EN55022 class B<br>lea**kage current**<br>full load at 240 Vac<br>1.5<br>mA<br>**MTBF**<br>MIL-HDSK-217F, 25°C ambient<br>450,000<br>hrs<br>**RoHS**<br>2011/65/EU<br>**ISCONTINUED**| |---| **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VPU-S200 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 01/08/2014 **│ page** 3 of 5 |**DERATING CURVES**<br>**ENVIRONMENTAL**<br>**parameter**<br>**conditions/description**<br>**min**<br>**typ**<br>**max**<br>**units**<br>vibration<br>(10 ~ 55 Hz, 1 hour per axis, 3 hours total)<br>2<br>**G**<br>operating temperature<br>-10<br>**65**<br>**°C**<br>storage temperature<br>-20<br>**75**<br>**°C**<br>operating humidity<br>non-condensing<br>20<br>**90**<br>**%**<br>storage humidity<br>non-condensing<br>0<br>**75**<br>**%**<br>**U**<br>**ED**| |---| ## **DERATING CURVES** output power vs. ambient temp **erature** a. 3.3 and 5 V models **b. all other models** **==> picture [422 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>2 2<br>80 80<br>60 1 60 1<br>40 40<br>20 20<br>-20 0 10 20 30 40 50 60 70 -20 0 10 20 30 40 50 60 70<br>Ambient Temperature (°C) Ambient Temperature (°C)<br>1 Convection<br>2 Forced air (0.5m3/min)<br> 18 CFM<br>Load (%) Load (%)<br>**----- End of picture text -----**<br> **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VPU-S200 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 01/08/2014 **│ page** 4 of 5 ## **MECHANICAL DRAWING** units: mm[inches] tolerance: ±0.2mm **==> picture [558 x 386] intentionally omitted <==** **----- Start of picture text -----**<br> JP1 used for Remote<br>On/Off control<br>160.7 6.327 JP1<br>0.5 3.50 THRU 1<br>i ; al<br>132.1 i 0.55.201 (4 PLCS)HOLES 3 7X90° 2<br>7<br>38.1 1.500<br>31.8 [ 1.252 ] [ ] DETAIL A<br>SCALE 2 : 1<br>es<br>172.7 6.799<br>162.5 [ 0.56.398 ]<br>_ _ [ ] FI<br>CN2<br>12<br>B or: cee ° Uf © 3<br>ee,,—___Xt_a 1a os 6 |<br>96.5 3.799<br>cle 2 ae qs? >. UES [<br>516 Bome heen. ean<br>63.5 2.500<br>LED OutputIndicator 1 CN1 0.5<br>5<br>Output Voltage<br>Adjuster we nC) ad. S :<br>a oy? = | 1 @ 6<br>Remote ON/OFF<br>Control (Optional) CN4 6 1 2 1 CN3 A M4X0.7<br>3.00mm DEEP<br>(8 PLCS)<br>CN1 CN2 CN3 CN4 RTN: Return terminals for logic signals.<br>ee<br>1 N 1 -Vo 1 FAN+ 1 RTN Same electrical potential as -Vo.<br>ee 2 n/c 2 es -Vo 2 ee FAN - 2 on/off RS+: Remote Sense positive terminals.<br>ee ee ee RS-: Remote Sense negative terminals.<br>ee 3 e L ee 3 e -Vo | 3 PG PG: Power good signal.<br>**----- End of picture text -----**<br> **==> picture [269 x 189] intentionally omitted <==** **----- Start of picture text -----**<br> CN1 CN2 CN3 CN4<br>ee<br>1 N 1 -Vo 1 FAN+ 1 RTN<br>ee es ee<br>2 n/c 2 -Vo 2 FAN - 2 on/off<br>ee ee ee<br>3 L 3 -Vo 3 PG<br>ee ee |<br>4 n/c 4 -Vo 4 RTN<br>|| «| [| |<br>5 FG 5 -Vo 5 RS+<br>| | ry | [=] |<br>6 -Vo 6 RS-<br>P= || |<br>7 + Vo<br>| |<br>8 +Vo<br>| [«][|]<br>9 +Vo<br>|<br>10 +Vo<br>11 +Vo<br>||<br>12 +Vo<br>|<br>**----- End of picture text -----**<br> **cui** .com Additional Resources: Product Page **CUI Inc │ SERIES:** VPU-S200 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 01/08/2014 **│ page** 5 of 5 |**rev.**<br>**description**<br>**date**<br>1.0<br>initial release<br>01/3**0/2006**<br>1.01<br>new template applied<br>1**2/19/2011**<br>1.02<br>V-Inf nitybrandingremoved<br>**08/22/2012**<br>1.03<br>corrected outputpower data<br>**10/12/2012**<br>1.04<br>updated isolation voltage<br>**01/08/2014**<br>The revision history provided is for informational purposes only and is believed**to be accurate.**<br>**N HISTORY**<br>**E**<br>|**D**| |---|---| ## **REVISION HISTORY** **==> picture [41 x 32] intentionally omitted <==** **Headquarters** 20050 SW 112th Ave. Fax 503.612.2383 Tualatin, OR 97062 **cui** .com **800.275.4899** techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →