Image not available
Illustrative purposes only
VOF-S60B-5
OPEN FRAME AC-DC CONVERTERS POWER SUPPLY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: VOF-S60B Series
| Delivery and price | |
|---|---|
| Units per pack | 6 |
| Price | 53.84 € |
| Current stock | 10+ |
| Lead time | 30 days |
Additional Resources: Product Page ~~re~~ | 3D Model | PCB Footprint **date** 03/07/2023 **page** 1 of 7 ## **SERIES:** VOF-S60B **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - universal input range (90 ~ 264 Vac) - option to support large transient loads (2x rated current)[3] - Class B emissions (EN55032/CISPR/FCC) - certified to IEC/EN/UL 62368-1 - short circuit protection - over voltage protection - < 150 mW no-load power consumption - Class II |rowsHAL;|CEFE©|||||| |---|---|---|---|---|---|---| |**MODEL**|**output**<br>**voltage**|**output**<br>**current**||**output**<br>**power**|**ripple**<br>**and noise1**|**efficiency2**| |||**min**|**max**|**max**|**max**|**typ**| ||(Vdc)|(A)|(A)|(W)|(mVp-p)|**(%)**| |VOF-S60B-5|5|0|8.00|40|50|86| |VOF-S60B-12|12|0|5.00|60|120|88| |VOF-S60B-15|15|0|4.00|60|150|88| |VOF-S60B-24|24|0|2.50|60|240|89| |VOF-S60B-36|36|0|1.67|60|360|89| |VOF-S60B-48|48|0|1.25|60|480|90| Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 0.1 µF ceramic and 10 µF electrolytic capacitors on the output. For model VOF-S60B-5, add a 0.1 µF ceramic and 47 µF electrolytic capacitors on the output. 2. At 230 Vac, full load, 25°C. 3. Parts with the “-PB” suffix can sustain 2 times the rated output load for 10 seconds (MAX) and 10% duty cycle (MAX). This functionality requires a 100 µF / 400 V capacitor connected between pins BC+ and BC-. See Power Boost Section below for more details. ## **PART NUMBER KEY** ## **- - VOF S60B XX - XX** Base Number “Blank” = No Power Boost PB = Power Boost Function Output Voltage **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VOF-S60B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/07/2023 **│ page** 2 of 7 |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage||90<br>120||264<br>370|Vac<br>Vdc| |frequency||47||63|Hz| |current|at 100 Vac<br>at 240 Vac|||1.5<br>0.8|A<br>A| |inrush current|at 240 Vac, cold start, 25°C|||120|A| |leakage current|at 264 Vac|||0.25|mA| |**OUTPUT**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||5 Vdc output models|||8,000|μF| ||12 Vdc output models|||5,000|μF| |capacitive load|15 Vdc output models<br>24 Vdc output models|||4,000<br>2,400|μF<br>μF| ||36 Vdc output models|||1,680|μF| ||48 Vdc output models|||680|μF| |initial set point accuracy|5 Vdc output models<br>all other models||±2<br>±1||%<br>%| |line regulation|measured at high line to low line at full load||±1||%| |load regulation|10%~100% load||±1||%| |start-up time|115 Vac<br>230 Vac||2<br>1||s<br>s| |hold-up time|at 115 Vac||10||ms| |switching frequency|||65||kHz| |temperature coefcient|||±0.05||%/°C| |**PROTECTIONS**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| ||TVS to clamp output voltage||||| ||5 Vdc output models||6.8||Vdc| ||12 Vdc output models||15.0||Vdc| |over voltage protection|15 Vdc output models||18.0||Vdc| ||24 Vdc output models||30.0||Vdc| ||36 Vdc output models||47.0||Vdc| ||48 Vdc output models||56.0||Vdc| |short circuit protection|hiccup, auto recovery||||| |**SAFETY & COMPLIANCE**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |isolation voltage|input to output for 1 minute|3,000|||Vac| |isolation resistance||100|||MΩ| |safety approvals|UL 62368-1, EN 62368-1, IEC 62368-1||||| |safety class|Class II||||| |conducted emissions|EN55032 2015, EN61000-6-3 2007+A1: 2011+AC:<br>47 CFR FCC Part 15 Subpart B (Class B)|2012, Class B,|||| |radiated emissions|EN55032 2015, EN61000-6-3 2007+A1: 2011+AC:<br>47 CFR FCC Part 15 Subpart B (Class B)|2012, Class B,|||| |harmonic current emissions|EN61000-3-2:2014||||| |voltage fuctuations & ficker|EN61000-3-3:2013||||| **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VOF-S60B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/07/2023 **│ page** 3 of 7 ## **SAFETY & COMPLIANCE (CONTINUED)** |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |---|---|---|---|---|---| |ESD|IEC61000-4-2:2008, air ±8kV||||| |radiated immunity|IEC61000-4-3:2010||||| |EFT/burst|IEC61000-4-4:2012, ±0.5 kV, ±1 kV, ±2 kV,||||| |surge|IEC61000-4-5:2014, ±0.5 kV, ±1 kV||||| |conducted immunity|IEC61000-4-6:2013||||| |power frequency magnetic feld|IEC61000-4-8:2009||||| |voltage dips & interruptions|IEC61000-4-11:2004, dip 30% 10 ms, dip 60%<br>IEC61000-4-11:2004, >95% 5000 ms|100ms, dip >95% 5000 ms|||| |MTBF|as per MIL-STD-217F, at 115 Vac, 25°C, GB|300,000|||hours| |RoHS|yes||||| |Notes:<br>4. The power supply is considered a component which will be installed into fnal equipment. The fnal equipment still must be tested to meet the necessary EMC directives.|||||| ## **ENVIRONMENTAL** |**ENVIRONMENTAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature|see derating curves|-30||70|°C| |storage temperature||-30||85|°C| |operating humidity|non-condensing|||93|%| |altitude||||5,000|m| |vibration|as per MIL-STD-810F Table 514.5C-VIII; 15~2000<br>Hz for 1 hour on each axis for 3 hours||4||G| |shock|as per MIL-STD-810F Table 516.5, Table 516.5-1;<br>for 10 ms on each axis 3 times||75||G| **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VOF-S60B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/07/2023 **│ page** 4 of 7 ## **DERATING CURVES** **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VOF-S60B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/07/2023 **│ page** 5 of 7 ## **MECHANICAL** |**MECHANICAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|2.00 x 2.00 x 1.346 (50.80 x 50.80 x 34.20 mm)||||inch| |weight|||93||g| ## **MECHANICAL DRAWING** units: inch [mm] tolerance: ±0.020[±0.50] |PIN CONNECTIONS|PIN CONNECTIONS|PIN CONNECTIONS| |---|---|---| |PIN|Function|| ||Standard|Power Boost| |1|AC (L)|AC (L)| |2|AC (N)|AC (N)| |3|+Vo|+Vo| |4|-Vo|-Vo| |5|No Connect|BC+| |6|No Connect|BC-| ## **EMC RECOMMENDATIONS** When used in a Class I system implementation (utilizing an Earth Ground connection as depicted in the schematic below), the VOF-S60B series requires additional inductance and Y-Caps to meet EN55032 Class B. These additional components are not required in a Class II implementation where no Earth Ground is present. |CHOKE|CHOKE|CHOKE|CHOKE| |---|---|---|---| |Specification|Inductance|Duplex<br>Winding/Turns|Manufacturers| |T10*6*5C<br>A15|2.6 mH|TIW-M<br>Φ 0.35*2/25T|ACME| |T10*6*5C<br>R15K|2.6 mH|TIW-M<br>Φ 0.35*2/25T|VAKOS| |Y-CAP|Y-CAP|Y-CAP|Y-CAP| |---|---|---|---| |Subclass|Withstand<br>Voltage|Capacitance|Manufacturers| |Y2 CAP|250 V (min.)|2200 pF (typ.)|TDK| |Y2 CAP|250 V (min.)|4700 pF (typ.)|TDK| **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VOF-S60B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/07/2023 **│ page** 6 of 7 ## **POWER BOOST** The VOF-S60B Series has an ordering option called Power Boost (“-PB” suffix), which can double the rated output power provided to the load for a maximum of 10 seconds and repeated duty cycle of 10%. This functionality requires a 100 uF / 400 V capacitor to be connected between the BC+ and BC- pins as depicted in the schematic below. This external capacitor is not required if the VOF-S60B is operating from 230 Vac mains. When utilizing the Power Boost Feature, care must be taken not to thermally overstress the unit. The combined load (nominal plus peak) should not exceed 65% of the full load rating when averaged out over time. ## **INSTALLATION INSTRUCTIONS** The mounting holes should all be 1.5 mm in diameter. A minimum of 4 mm clearance is required for all four sides of the unit and a minimum of 5 mm clearance is required above the top surface of the unit. **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VOF-S60B **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/07/2023 **│ page** 7 of 7 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|02/12/2020| |1.01|updates to mechanical &power boost sections|04/08/2020| |1.02|updated mechanical drawing|05/15/2020| |1.03|circuit fgures and derating curves updated|04/28/2021| |1.04|mechanical drawing updated|06/04/2021| |1.05|safety marks updated|03/07/2023| The revision history provided is for informational purposes only and is believed to be accurate. **==> picture [155 x 34] intentionally omitted <==** **Headquarters** 20050 SW 112th Ave. Tualatin, OR 97062 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →