Image not available
Illustrative purposes only
PMC-24V300W1BA.
AC/DC Enclosed Power Supply (PSU), ITE, 2 Outputs, 306 W, 24 VDC, 12.5 A, 12 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DELTA ELECTRONICS
- Product type: AC / DC Enclosed Power Supplies
- SVHC: To Be Advised
- Product Range: PMC Series
- No. of Outputs: 2Outputs
- Output Power Max: 306W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 12.5A
- Output Current - Output 2: 500mA
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: 12VDC
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 59.81 € |
| Current stock | 10+ |
| Lead time | 30 days |
**TECHNICAL DATASHEET** **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## **PMC** ## **Highlights & Features** - Universal AC input voltage range - Full corrosion resistant aluminium casing - High PF > 0.99 @ 115Vac - Built-in Remote On/Off and 12V SB (STANDBY) / 0.5A - High MTBF > 700,000 hrs per Telcordia SR-332 - Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and EMI to EN 55032, Class B - Overvoltage / Overcurrent / Over Temperature Protections - IP20 certified **Safety Standards** . — CE We CB Certified for worldwide use **Model Number:** PMC-24V300W1BA **Unit Weight:** 0.82 kg (1.81 lb) **Dimensions (L x W x H):** 199 x 105 x 41 mm (7.83 x 4.13 x 1.61 inch) ## **General Description** The Hi-End Panel Mount Power Supply with Remote sense function & 12V STANDBY / 0.5A is the latest offering from one of the world’s largest power supply manufacturers and solution providers - Delta. The product range offers a nominal output voltage of 24V, a wide temperature range from -10°C to +70°C and a highly dependable minimum holdup time. The state-of-the-art design is made to withstand harsh industrial environments. What makes the product stands out from the crowd is its lightweight full aluminum body design which can withstand shock and vibration according to IEC60068-2. The PMC series also offers overvoltage and overload protection. Using a wide input voltage range design, it is compatible worldwide. The input also includes DC operating voltage from 125-375Vdc. Best of all, this excellent design and quality does not come with a big price tag. ## **Model Information** PMC Panel Mount Power Supply |**ModelNumber**|**Input Voltage Range**|**Rated OutputVoltage**|**Rated Output Current**| |---|---|---|---| |PMC-24V300W1BA|85-264Vac (125-375Vdc)|24Vdc|V1: 12.5A, V2 SB: 0.50A| ## **Model Numbering** |**PMC**|**24V**|**300W**|**1**|**B**|**A**|| |---|---|---|---|---|---|---| |PMC Series|Output Voltage|Output Power|Single Phase|With PFC|IP20 Connector|IP20 Connector| | All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 1 **www.DeltaPSU.com (November 2020, Rev. 06)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## **Specifications** ## Input Ratings / Characteristics |**Specifications**<br>Input Ratings / Characteristics|**Specifications**<br>Input Ratings / Characteristics|| |---|---|---| |Nominal Input Voltage||100-240Vac| |Input Voltage Range||85-264Vac| |Nominal Input Frequency||50-60Hz| |Input FrequencyRange||47-63Hz| |Nominal DC Input Voltage||125-250Vdc| |DC Input Voltage Range*||125-375Vdc| |Input Current||< 4.0A@115Vac, < 2.0A@230Vac| |Efficiency at 100% Load||> 86% @ 115Vac, > 88% @ 230Vac| |Max Power Dissipation|0% load|< 4.4W@115Vac & < 4.0W@230Vac| ||100% load|< 49W@115Vac & < 38W@230Vac| |Max Inrush Current(Cold Start)||< 35A@115Vac, < 70A@230Vac| |Power Factor at 100% Load||>0.99@115Vac , > 0.97@230Vac| |Leakage Current||< 1mA@240Vac| *Fulfills test conditions for DC input. Safety approval for DC input can be obtained upon request. ## Output Ratings / Characteristics** |Output Ratings / Characteristics**|| |---|---| |Nominal Output Voltage|V1: 24Vdc, V2 SB: 12Vdc| |Factory Set Point Tolerance|V1: 24Vdc ± 2%| |Output Voltage Adjustment Range|V1: 22-28Vdc| |Output Current|V1: 0-12.5A, V2 SB: 0-0.50A (306W max.)| |Output Power|306W| |Line Regulation|< 0.5%(@85 to 264Vac input, 100% load)| |Load Regulation|< 1% (@ 85 to 264Vac input, 0-100% load)| |PARD***(20MHz)|V1: <100mVpp , V2 SB: <200mVpp| |Rise Time|< 30ms@nominal input(100% load)| |Start-up Time|< 1,000ms@nominal input(100% load)| |Hold-upTime|> 15ms@nominal input,100% load| |Dynamic Response<br>(Overshoot & Undershoot O/P Voltage)|± 5% @ 85-264Vac input, 0-100% load<br>(Slew Rate: 0.1A/μS, 50% dutycycle@5Hz)| |Start-upwith Capacitive Loads|8,000µF Max| **For power de-rating from 50°C to 70°C, see power de-rating on page 3. ***PARD is measured with an AC coupling mode, 5cm wires, and in parallel with 0.1µF ceramic capacitor & 47µF electrolytic capacitor. | All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 2 **www.DeltaPSU.com (November 2020, Rev. 06)** 2 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## Mechanical |Mechanical|Mechanical|Mechanical|| |---|---|---|---| |Case Cover|||Aluminium| |Dimensions (L x W x H)|||199 x 105 x 41 mm(7.83 x 4.13 x 1.61 inch)| |Unit Weight|||0.82 kg (1.81 lb)| |LED Indicator||Green LED|DC OK| |Cooling System|||Forced Cooling (Built-in Fan)| |Terminal|CN1|Input and Output M3.5 x 7 Pins (Rated 300Vac/20A)|Input and Output M3.5 x 7 Pins (Rated 300Vac/20A)| ||CN2|Power Supply Header JST: S8B-PHDSS(LF)(SN)|Power Supply Header JST: S8B-PHDSS(LF)(SN)| |||Mating Connector|JST: PHDR-08VS or equivalent| |||Terminal JST: SPHD-001T-P0.5 (x8) or equivalent|Terminal JST: SPHD-001T-P0.5 (x8) or equivalent| |Wire|CN1|Input and Output AWG 18-16|Input and Output AWG 18-16| ||CN2|Mating Connector|AWG 24| |Noise (1 Meter from power supply)|||Sound Pressure Level(SPL)< 40dBA| ## Environment |Environment||| |---|---|---| |Surrounding Air Temperature|Operating|-10°C to +70°C| ||Storage|-25°C to +85°C| |Power De-rating||> 50°C de-rate power by 2.5% / °C| |OperatingHumidity||5 to 95% RH(Non-Condensing)| |OperatingAltitude||0 to 3,000 Meters(9,840 ft.)| |Shock Test|Non-Operating|IEC60068-2-27, 30G (300m/S²) for a duration of 18ms<br>3 times per direction, 18 times in total| |Vibration|Non-Operating|IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak);<br>20 minper axis for all X,Y,Z direction| |Bump|Operating|IEC 60068-2-29, 10G (100m/S²) for a duration of 11ms,1000<br>times per direction, 6000 times in total| |Over Voltage Category||II| |Pollution Degree||2| ## Protections |Protections|| |---|---| |Overvoltage|V1: < 32V ±10%, V2 SB: < 16V ±15%, SELV output,<br>HiccupMode, Non-Latching (Auto-Recovery).| |Overload / Overcurrent|> 120% of rated load current, Hiccup Mode,<br>Non-Latching (Auto-Recovery).| |Over Temperature|< 75°C Ambient Temp@ 100% load,<br>Non-Latching (Auto-Recovery).| |Short Circuit|Hiccup Mode, Non-Latching<br>(Auto-recoverywhen the fault is removed).| |Internal Fuse at L pin|T6.3AH| |Degree of Protection|IP20| |Protection Against Shock|Class I with PE* connection| *PE: Primary Earth All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 3 | **www.DeltaPSU.com (November 2020, Rev. 06)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## Reliability Data |Reliability Data||| |---|---|---| |MTBF||> 700,000 hrs, as per Telcordia SR-332| |||I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C| |Expected Cap Life Time||10years(115Vac & 230Vac, 50% load@40°C)| |Safety Standards / Directives||| |SafetyEntryLow Voltage||SELV(EN 60950-1)| |Electrical Safety|SIQ Bauart|EN 60950-1, EN 62368-1| ||UL/cUL recognized|UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395)| |||UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395)| ||CCC|GB4943| ||CB scheme|IEC 60950-1, IEC 62368-1| |CE||In conformance with EMC Directive 2014/30/EU and Low| |||Voltage Directive 2014/35/EU| |Galvanic Isolation|Input to Output|3.0 KVac| ||Input to Ground|1.5 KVac| ||Output to Ground|0.5 KVac| ## Safety Standards / Directives | All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 4 **www.DeltaPSU.com (November 2020, Rev. 06)** 4 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA |EMC||| |---|---|---| |Emissions (CE & RE)|Generic Standards: CISPR32, EN55032,<br>FCC Title 47: Class B,GB9254|| |Immunity|Generic Standards: EN 55024|| |Electrostatic Discharge<br>IEC61000-4-2|Level 4 Criteria A1)<br>Air Discharge: 15kV<br>Contact Discharge: 8kV|| |Radiated Field<br>IEC61000-4-3|Level 3 Criteria A1)<br>80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation|| |Electrical Fast Transient / Burst<br>IEC61000-4-4|Level 3 Criteria A1)<br>2kV|| |Surge<br>IEC61000-4-5|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV|| |Conducted<br>IEC61000-4-6|Level 3 Criteria A1)<br>150kHz-80MHz, 10Vrms|| |Power Frequency Magnetic Fields<br>IEC61000-4-8|Criteria A1)<br>10A/Meter|| |Voltage Dips and Interruptions<br>IEC61000-4-11|0% of 100Vac, 20ms<br>40% of 100Vac, 200ms<br>70% of 100Vac, 500ms<br>0% of 100Vac, 5000ms<br>0% of 240Vac, 20ms<br>40% of 240Vac, 200ms<br>70% of 240Vac, 500ms<br>0% of 240Vac, 5000ms|Criteria A1)<br>Criteria B2)<br>Criteria A1)<br>Criteria B2)<br>Criteria A1)<br>Criteria B2)<br>Criteria A1)<br>Criteria B2)| |Low Energy Pulse Test (Ring Wave)<br>IEC61000-4-12|Level 3 Criteria A1)<br>Common Mode2): 2kV<br>Differential Mode3): 1kV|| |Harmonic Current Emission|IEC/EN 61000-3-2, Class A|| |Voltage Fluctuation and Flicker|IEC/EN 61000-3-3|| - 1) Criteria A: Normal performance within the specification limits - 2) Criteria B: Temporary degradation or loss of function which is self-recoverable - 3) Asymmetrical: Common mode (Line to earth) - 4) Symmetrical: Differential mode (Line to line) | All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 5 **www.DeltaPSU.com (November 2020, Rev. 06)** 5 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## **Block Diagram** ## **Device Description** **==> picture [94 x 180] intentionally omitted <==** **----- Start of picture text -----**<br> Side surface<br>Top surface<br>Q<br>ZLf| SS<J p)<br>SEE ac<br>8 Kee = seDae ~<br><x ‘ Fya<br>° . Fy .<br>|Ber<br>**----- End of picture text -----**<br> - 1) Input & Output IP20 connector - 2) DC Voltage adjustment potentiometer - 3) DC OK control LED (Green) - 4) CN2: Remote Sense Function & 12V STANDBY / 0.5A - 5) DC Fan and Air flow direction All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 6 **www.DeltaPSU.com (November 2020, Rev. 06)** 6 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## **Dimensions** **L x W x H:** 199 x 105 x 41 mm (7.83 x 4.13 x 1.61 inch) ## **Engineering Data** Output Load De-rating VS Surrounding Air Temperature ## **Note** 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature exceeds its specification as defined on Page 3 under “Environment”, the device may run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance as recommended in the safety instructions while the device is in operation. **Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation** > 50°C de-rate power by 2.5% / °C 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. If the device has to be mounted in any other orientation, please contact **info@deltapsu.com** for more details. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 7 **www.DeltaPSU.com (November 2020, Rev. 06)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA Output Load De-rating VS Input Voltage - No output power de-rating across the entire input voltage range ## **Assembly & Installation** Mounting - Ⓐ Mounting holes - Ⓑ Input / Output connector - Ⓒ Mounting surface (customer system) - Ⓓ DC FAN **==> picture [511 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> a Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)<br>**----- End of picture text -----**<br> **==> picture [131 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Fig. 2 Mounting Orientation<br>**----- End of picture text -----**<br> - Use flexible cable (stranded or solid) of AWG No. 20-16. - The torque at the Connector shall not exceed 13Kgf.cm (11.23 lbf.in). The insulation stripping length should not exceed 0.275” or 7mm. - Please refer Table 1 for the recommended Mating Connector, Terminal and AWG wire size. ~~EE~~ **Table 1 Power Supply Header Mating Connector Terminal AWG** S8B-PHDSS(LF)(SN) PHDR-08VS or SPHD-001T-P0.5 (x8) 24 **CN2 JST** ~~| ee~~ equivalent ~~ES~~ or equivalent | All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 8 **www.DeltaPSU.com (November 2020, Rev. 06)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## Installation - Only use M4 screw ≤ 4.5 mm through the base mounting holes. This is to keep a safe distance between the screw and internal components. - Recommended mounting tightening torque: 4~8 Kgf.cm ## Safety Instructions - To ensure sufficient convection cooling, always maintain a safety distance of > 20mm (0.78 inch) from all ventilated surfaces while the device is in operation. - The device is not recommended to be placed on low thermal conductive surface, for example, plastics. - Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! - Do not touch the terminals while power is being supplied. Risk of electric shock. - Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: - - Electric shock; Safety Hazard; Fire; Product failure - Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. ## **Functional Manual** Pin Assignment of CN2 **==> picture [30 x 127] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1<br>oO oO<br>Ooo o O<br>a<br>8 7<br>**----- End of picture text -----**<br> |**Pin**|**Functions**|**Descriptions**| |---|---|---| |1|Remote on/off|Turn the output on and off by electrical SW or dry contact<br>between Pin 5(GND); Short: Power OFF, Open: Power ON| |2, 4, 6|NC|No Application| |3|12V (SB)/ 0.5A|Auxiliary Voltage output 11.4 -12.6V, Reference to Pin 5<br>(GND). Themaximum load currentis 0.5A| |5|GND|Ground reference for Remote on/off and 12V (SB)| |7|+S|Positive sensing. The +S Signal should be connected to the<br>positive terminal of the load| |8|-S|Negative sensing. The -S signal should e connected to the<br>negative terminal of the load| | All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 9 **www.DeltaPSU.com (November 2020, Rev. 06)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## Configuration of CN2 1. Remote sense **==> picture [20 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> CN2<br>**----- End of picture text -----**<br> 2. Auxiliary Voltage: 12V (SB)/ 0.5A 3. Remote on/off **Between pin1 and GND (pin5) Output Status** SW ON (Short) OFF SW OFF (Open) ON All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 06)** 10 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## **Functions** - **Graph illustrating the Start-up Time, Rise Time, and Hold-up Time** ## Start-up Time The time required for the output voltage to reach 90% of its final steady state set value, after the input voltage is applied. ## Rise Time The time required for the output voltage to change from 10% to 90% of its final steady state set value. ## Hold-up Time Time between the collapse of the AC input voltage, and the output falling to 95% of its steady state set value. ## Inrush Current Inrush Current is the first surge current seen on the input side when AC input is applied to the power supply. It is the first pulse captured; see a typical picture for the inrush current as seen in the power supply. ## Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0% to 100% of its rated current. - **50% duty cycle / 5Hz** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 11 **www.DeltaPSU.com (November 2020, Rev. 06)** **TECHNICAL DATASHEET** **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## Overload & Overcurrent Protections (Auto-Recovery) The power supply’s Overload (OLP) and Over current (OCP) Protections will be activated when output current (IO) exceeds its specification as defined on Page 3 under “Protections. In such occurrence, the output voltage (VO) will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (AutoRecovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. ## Overvoltage Protection (Auto-Recovery) The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. ## Over Temperature Protection (Auto-Recovery) It is not recommended to prolong the duration of IO when it is less than OLP/OCP point, but greater than 100%, since it may cause damage to the PSU. As described in load de-rating section, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recommended in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph. ## Short Circuit Protection (Auto-Recovery) The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 06)** 12 **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## Operating Mode ## **Redundant Operation** In order to ensure proper redundant operation for the power supply unit (PSU), the output voltage difference between the two units must be kept at 0.45~0.50V for 24V supplies. Follow simple steps given below to set them up for the redundant operation: ## **Step 1.** Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then VO of PSU 1 must be higher than PSU 2. In order to set the output voltage, individually connect the power supply to 50% of rated load at any line voltage from 85-264Vac, and set the PSU 1 and PSU 2 output voltage. ## **Step 2.** Connect the power supply units PSU 1 and PSU 2 to Vin 1 & Vin 2, respectively, of the DRR-20N (or 20A) module shown on the diagram on the right. ## **Step 3.** Connect the system load from Vout. Please note that output voltage Vout from DRR module will be = VO (output voltage of power supply) – Vdrop* (in DRR module). **The Signal GND in the DRR module is for the built-in LED and DC OK signals. The Output GND terminals from the two PSU’s do not need to be connected to the Signal GND terminal. ## **Fig. 3 Redundant Operation Connection Diagram** *Vdrop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature. ## **Parallel Operation** The power supply units (PSUs) can also be used for parallel operation in order to increase the output power. The difference in output voltage between the two units must be kept to within 25mV of each other. This difference must be verified with the same output load connected independently to each unit. Parameters such as EMI, inrush current, leakage current, PARD, start up time will be different from those on the datasheet, when two units are connected in parallel. The user will need to verify that any differences will still allow the two power supplies connected in parallel will work properly in their product/application. **Fig. 4 Parallel Operation Connection Diagram** All parameters are specified at 25°C ambient and AC input unless otherwise indicated. **www.DeltaPSU.com (November 2020, Rev. 06)** 13 **TECHNICAL DATASHEET** **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA **Fig. 5 DC Input Operation Connection Diagram** ## **DC Input Operation** ## **Step 1.** Use a battery or similar DC source. ## **Step 2.** Connect +pole to L and -pole to N. ## **Step 3.** Connect the PE terminal to an earth wire or to the machine ground. **Fig. 6 2 of 3 Phase System Input Operation Connection Diagram** ## **2 of 3 Phase System Input Operation** Delta's PMC can use on 2 of 3 phase system. Please refer to the following step. ## **Step 1.** The input voltage applied from Line to Neutral is below the maximum rated input. The input voltage shall be below 240Vac +10%. ## **Step 2.** The external protector is needed on N (Neutral) input line to secure a safety. N line does not have internal fuse protection. An appropriate fuse or circuit breaker should be connected in series with N input line connection like the following. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 14 **www.DeltaPSU.com (November 2020, Rev. 06)** **TECHNICAL DATASHEET** ## **PMC Panel Mount Power Supply** 24V 300W 1 Phase / PMC-24V300W1BA ## **Others** ## PFC – Norm EN 61000-3-2 ## **Line Current harmonic** Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000-3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs, Frequently, the user does not profit form fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this standard for a specific application. This product conforms to this standard. ## Attention Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail (please refer to www.DeltaPSU.com for the latest datasheets information). Delta shall have no liability of indemnification for any claim or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of using the product before placing an order with Delta. Delta reserves the right to make changes to the information described in the datasheets without notice. All parameters are specified at 25°C ambient and AC input unless otherwise indicated. 15 | **www.DeltaPSU.com (November 2020, Rev. 06)**
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →