Image not available
Illustrative purposes only
PEL 230/5-5,5
AC/DC DIN Rail Power Supply (PSU), ITE, 1 Output, 27.5 W, 5 VDC, 5.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BLOCK
- Product type:
- SVHC: No SVHC (21-Jan-2025)
- Product Range: PEL Series
- No. of Outputs: 1 Output
- Output Power Max: 27.5W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Current - Output 4: -
- Output Voltage - Output 1: 5VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 84.13 € |
| Current stock | 10+ |
| Lead time | 30 days |
**PEL 230** Primär getaktete Gleichstromversorgung Primary switched mode Power supply | deutsch english ## **BLOCK Transformatoren-Elektronik GmbH** Max-Planck-Straße 36-46[.] 27283 Verden, Germany info@block.eu[.] block.eu block.eu **==> picture [160 x 115] intentionally omitted <==** **----- Start of picture text -----**<br> 3 Einganginput Ausgang 4<br>L N output<br>+ + – –<br>Ausgangskennlinie (U/I Kennlinie)<br>Output Characteristic (U/I Charakteristic)<br>Uout(V)<br>1<br>p a IN Iout(A)<br>2 1,1 x IN<br>**----- End of picture text -----**<br> **==> picture [25 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Fig. 1<br>**----- End of picture text -----**<br> Uout **– +** **==> picture [9 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> 6<br>**----- End of picture text -----**<br> ## Installation ## **Sicherheitsmaßnahmen vor der Installation** Das Betriebsmittel ist vor unzulässiger Beanspruchung zu schützen. Insbesondere dürfen bei Transport und Handhabung keine Bauelemente verbogen und/oder Isolationsabstände verändert werden. Die Berührung elektrischer Bauelemente und Kontakte ist zu vermeiden. Das Betriebsmittel immer im spannungsfreien Zustand montieren und verdrahten. Die Produktbeschreibung und die technischen Hinweise in unserem Hauptkatalog sowie die Aufschriften am Betriebsmittel und auf dem Typenschild sind zu beachten. **Installation** Die Installation ist entsprechend den örtlichen Gegebenheiten, einschlägigen Vorschriften (z. B. VDE 0100), nationalen Unfallverhütungsvorschriften (z. B. UVV-VBG4 bzw. BGV A3) und den anerkannten Regeln der Technik durchzuführen. Dieses elektrische Betriebsmittel ist eine Komponente, die zum Einbau in elektrische Anlagen oder Maschinen bestimmt ist und erfüllt die Anforderungen der Niederspannungsrichtlinie (2014/35/EU). Der geforderte Mindestabstand zu benachbarten Teilen ist einzuhalten, um die Kühlung nicht zu behindern! Bei Einbau in Maschinen ist die Aufnahme des bestimmungsgemäßen Betriebes solange untersagt, bis festgestellt wurde, dass die Maschine den Bestimmungen der Maschinenrichtlinie 2006/42/EG entspricht. EN 60204 ist zu beachten. Die Aufnahme des bestimmungsgemäßen Betriebes ist nur bei Einhaltung der EMV-Richtlinie (2014/30/ EU) erlaubt. Die Einhaltung der durch die EMV-Gesetzgebung geforderten Grenzwerte liegt in der Verantwortung des Herstellers der Anlage oder Maschine. 1 **Betriebsanzeige** : Die grüne LED leuchtet, sofern die Ausgangsspannung vorhanden ist. 2 **Ausgangsspannung** : Die Ausgangsspannung kann mit einem Schraubendreher verändert werden. Drehung im Uhrzeigersinn erhöht die Ausgangsspannung. Drehung gegen den Uhrzeigersinn verringert die Ausgangsspannung. ## 3 **Eingang** 4 **Ausgang** 5 **Montage** : Setzen Sie das Gerät mit der Tragschienenführung an die Oberkante der Tragschiene an und rasten Sie es nach unten ein. 6 **Demontage:** Ziehen Sie den Schnappriegel mit Hilfe eines Schraubendrehers auf und hängen Sie das Gerät an der Unterkante der Tragschiene aus. ## Installation ## **Safety measures before installation** This equipment is to be protected against improper use. Components are not to be bent or isolation spacing changed, especially through handling and transport. The contact with electrical components and terminals is to be avoided. Always disconnect the equipment from the mains supply, before commencing installation or wiring. The product description, technical information in our main catalogue and the marking on the equipment ratings plate are to be observed. **Installation** Installation must be carried out according to the prevailing local conditions and safety regulations (e.g. VDE 0100) national accident prevention regulations (e.g. UVV-VBG4 or BGV A3) and the generally accepted rules of technology. This equipment is a component designed for installation into electrical systems and machines, and fulfils the requirements of the low voltage guidelines (2014/35/EU). The required minimum spacing to neighbouring components must be observed to guarantee the required cooling. When installed into machinery, the normal operation is forbidden until it is determined that the machine fulfils the requirements of the machinery guidelines 2006/42/EG. EN 60204 must be observed. The EMC requirements (2014/30/EU) must be fulfilled before operation is commenced. The observance of the required limitations for the EMC legislation is the responsibility of the manufacturer of the installation or machinery. ## 1 **Power indicator** : The green LED lights as soon as the output voltage is present. - 2 **Output voltage** : The output voltage can be altered using a screwdriver. Turning the adjustment screw clockwise raises the output voltage. Turning the adjustment screw anticlockwise reduce the output voltage. - 3 **Input** 4 **Output** - 5 **Mounting** : Place the device with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. - 6 **Removing** : Pull the snap lever open with the aid of a screwdriver and slide the device out at the lower edge of the DIN rail. Funktionsschaltbild für PEL 230 Functional diagram for PEL 230 **==> picture [271 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> L (–)<br>–<br>–<br>N (+)* Stand-by +<br>acy h +<br>LED (Green)<br>**----- End of picture text -----**<br> * Zweiphasenbetrieb nur möglich, sofern die maximale Eingangsspannung von 264 Vac nicht überschritten wird. - Two phase operation only possible, if input voltage under 264 Vac. 5 ## deutsch english Technische Daten Technical data **==> picture [817 x 492] intentionally omitted <==** **----- Start of picture text -----**<br> PEL 230/5-5,5 PEL 230/12-2 PEL 230/12-4 PEL 230/12-6,5 PEL 230/18-1,1 PEL 230/18-2,5 PEL 230/24-1,3 PEL 230/24-2, 5 PEL 230/24-4<br>Eingangsdaten Input data<br>Eingangsnennspannung Rated input voltage 100 - 240 Vac<br>Eingangsspannungsbereich Input voltage range 85 - 264 Vac (120 - 373 Vdc)<br>Eingangsspannungsderating Input voltage derating - max. 1,5 A (<100 Vac) max. 3,5 A (<100 Vac) max. 6 A (<100 Vac) /5,5 A (< 90 Vac) - max. 2 A (<100 Vac) max. 1 A (<100 Vac) max. 2 A (<100 Vac) /1,8 A (< 90 Vac) Vac) / 3 A (< 90 Vac)max. 3,5 A (<100<br>Nennfrequenzbereich Frequency range 44 Hz - 66 Hz / 0 Hz<br>0,56 A (110 Vac) / 0,6 A (110 Vac) / 0,9 A (110 Vac) / 1,5 A (110 Vac) / 0,45 A (110 Vac) / 0,72 A (110 Vac) / 0,7 A (110 Vac) / 1,4 A (110 Vac) / 1,6 A (110 Vac) /<br>Eingangsnennstrom (Nennlast) Nominal input current (nominal load) 0,29 A (230 Vac) 0,4 A (230 Vac) 0,5 A (230 Vac) 0,8 A (230 Vac) 0,23 A (230 Vac) 0,42 A (230 Vac) 0,5 A (230 Vac) 0,6 A (230 Vac) 0,9 A (230 Vac)<br>Einschaltstrombegrenzung Inrush current limitation < 30 A, NTC<br>Eingangssicherung intern Internal fuse 2 AT 4 AT 2 AT 4 AT 2 AT 4 AT<br>Empfohlene Vorsicherung* Recommended external protection* 6 A, 10 A, 16 A, Charakteristik B, C<br>10 ms (110 Vac) / 15 ms (110 Vac) / 10 ms (110 Vac) / 25 ms (110 Vac) / 10 ms (110 Vac) / 15 ms (110 Vac) /<br>Netzausfallüberbrückung bei Nennlast Mains drop compensation at nominal load 80 ms (230 Vac) 100 ms (230 Vac) 80 ms (230 Vac) 120 ms (230 Vac) 80 ms (230 Vac) 100 ms (230 Vac)<br>Ausgangsdaten Output data<br>Ausgangsspannung Rated output voltage 5 Vdc ±2 % 12 Vdc ±2 % 18 Vdc ±2 % 24 Vdc ±2 %<br>Ausgangsspannungsbereich Output voltage range 4,5 - 8,5 Vdc 10,5 - 15,5 Vdc 15,5 - 19 Vdc 15 - 28 Vdc 22,8 - 26,4 Vdc<br>Ausgangsstrom Rated output current 5,5 A 2 A 4 A 6,5 A 1,1 A 2,5 A 1,3 A 2,5 A 4 A<br>Überlastverhalten Overloadbehaviour Konstantstrom (U/I Kennlinie) Constant current (U/I Line)<br>Parallelschaltbar Parallel operation √<br>Serienschaltbar Serial operation √<br>Wirkungsgrad Efficiency typ. 85 % typ. 80 % typ. 85 % typ. 87 % typ. 80 % typ. 83 % typ. 82 % typ. 88 %<br>2,4 W / 9,35 W / 2,2 W / 8,5 W < 1 W / 12,5 W / 2,3 W / 5 W / 1 W / 9,2 W / 2,6 W / 7 W / 2,2 W / 8,5 W / 0,8 W / 13,1 W /<br>Verlustleistung (Leerlauf / Nennlast / Maximum) Power loss (idle / nominal load / typ. maximum) 9,85 W 2,6 W / 6 W / 6 W / 9 W 13 W 5,5 W 11 W 7,3 W 10,5 W 14,8 W<br>Restwelligkeit (Nennlast) Residual ripple (nominal load) typ. 100 mVss typ. 50 mVss typ. 100 mVss<br>Signalisierung Signaling<br>Betriebsanzeige Power indicator LED green<br>Umwelt Environment<br>Lagertemperatur Storage temperature -25 °C ... +80 °C<br>-25 °C ... +60 °C (UL: -25 °C – +55 °C)<br>Umgebungstemperatur Operational temperature Anlauf bei -40 °C typgeprüft Device start at -40 °C type-tested<br>Derating Derating -3%/K > +45 °C − -3%/K > +45 °C<br>Einbaulage Mounting position waagerecht für Tragschiene TH 35, horizontal for Rail TH 35<br>Zulässige Luftfeuchtigkeit Allowable humidity 5 bis 96 % relative Feuchte, keine Betauung zulässig5 to 96 % relative humidity with no dew<br>Strombelastbarkeit bei beliebiger Einbauanlage Current rating at any mounting position max. 3,5 A max. 1,4 A max. 2,4 A max. 3,9 A max. 0,8 A max. 1,6 A max. 0,9 A max. 1,6 A max. 2,4 A<br>Kühlung (Abstand zu benachbarten Teilen) Cooling (spacing to vicinal components) kein Mindestabstand rechts/links erforderlich, 50 mm oben/unten No minimum spacing right/left required, 50 mm over/under<br>Sicherheit und Schutz Safety and protection<br>Schutzart Protection index IP 20<br>Prüfspannung HV test voltage 4,2 kVdc<br>Schutzklasse Safety class II (im geschlossenen Schaltschrank) II ( in the closed Cabinet)<br>Anschlusskabel Conductors Zum Anschluss Kupferkabel mit min. 75 °C vewenden Use Copper Conductors only, rated min. 75 °C<br>Einsatzbereich Installation Einsatz in Bereichen mit Verschmutzungsgrad 2 For installation in Pollution Degree 2 environment<br>Überspannungskategorie Overvoltage category II<br>Rückspeisungsfestigkeit Feedback voltage max. 10 Vdc max. 25 Vdc max. 35 Vdc max. 30 Vdc<br>Normen Safety standards<br>Sicherheit Safety EN 61558-2-16, EN 60950-1<br>EMV EMC EN 61204-3<br>Zulassungen Approvals<br>UL UL UL-Note: Output disconnectinUL 508 (listed), UL 60950-1 (recognized) g means shall be provided during installation.<br>GL GL vorbereitet prepared Environmental category: C, EMC2 vorbereitet prepared Environmental category: C, EMC2<br>Mechanische Daten Mechanical data<br>Gewicht Weight 0,24 kg 0,17 kg 0,24 kg 0,3 kg 0,17 kg 0,24 kg 0,17 kg 0,24 kg 0,3 kg<br>Maße (B x H x T)** Dimensions (W x H x D)** 72 x 89 x 55 mm 54 x 89 x 55 mm 72 x 89 x 55 mm 90 x 89 x 55 mm 54 x 89 x 55 mm 72 x 89 x 55 mm 54 x 89 x 55 mm 72 x 89 x 55 mm 90 x 89 x 55 mm<br>Anschlüsse Eingang (L, N) Terminals input (L, N) Federzug, max. 2,5 mm [2 ] Spring-clamp terminals max. 2.5mm [2]<br>Anschlüsse Ausgang (+, +, -, -) Terminals output (+, +, -, -) Federzug, max. 2,5 mm [2] Spring-clamp terminals max. 2.5 mm [2]<br>Bestellnummern Order Numbers<br>Bestellnummer Order Number PEL 230 /5-5,5 PEL 230 /12-2 PEL 230/12-4 PEL 230/12-6,5 PEL 230/18-1,1 PEL 230/18-2,5 PEL 230/24-1,3 PEL 230/24-2,5 PEL 230/24-4<br>**----- End of picture text -----**<br> * Für DC Eingangsspannung ist eine geeignete DC-Sicherung erforderlich. For DC input voltage suitable DC fuse required. ** Tiefe T ab Oberkante Tragschiene. depth from upper edge of DIN rail.
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →