Image not available
Illustrative purposes only
PDRC-75-12
DIN RAIL MOUNT AC / DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type:
- SVHC: To Be Advised
- Product Range: PDRB-75 Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 91.78 € |
| Current stock | 25+ |
| Lead time | 30 days |
Additional Resources: Product Page **date** 02/21/2022 **page** 1 of 6 ## **SERIES:** PDRC-75 **DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY ## **FEATURES** |**MODEL**<br>**output**<br>**voltage**<br>(Vdc)<br>PDRC-75-5<br>5<br>PDRC-75-12<br>12<br>PDRC-75-15<br>15<br>PDRC-75-24<br>24<br>PDRC-75-24-23<br>24<br>• DC On/Low LED indicators<br>elo<br>eun<br>Hous «Gs<br>CE||**output**<br>**current**<br>**output**<br>**power**<br>**ripple**<br>**and noise1**<br>**max**<br>(A)<br>**max**<br>(W)<br>**max**<br>(mVp-p)<br>**(%)**<br>12.0<br>60<br>50<br>80<br>6.0<br>72<br>50<br>86<br>5.0<br>75<br>50<br>86<br>4.2<br>100<br>50<br>89<br>3.8<br>91<br>50<br>89<br>TINUED<br>v<br>f<br>ait<br>ry<br>:|cy|**2**| |---|---|---|---|---| |Notes:<br>1. At full load, nominal input, 20 MHz bandwidth oscilloscope.||||| |2. At nominal input.||||| |**PART NUMBER KEY**<br>DISC|Base Number|Base Number<br>**PDRC-75- XX**||| **cui** .com Additional Resources: Product Page **date** 02/21/2022 **page** 2 of 6 **CUI Inc SERIES:** PDRC-75 **DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|typ|**max**|**units**| |voltage||90<br>120||264<br>375|Vac<br>Vdc| |frequency||47||63|Hz| |current<br>inrush current<br>**OUTPUT**<br>leaka|at 90 Vac, full load<br>5 Vdc output model<br>12, 15 output model<br>24 Vdc output model<br>at 115 Vac, full load<br>at 230 Vac, full load<br>input to output|||1.5<br>1.7<br>2.2<br>A<br>A<br>A<br>30<br>60<br>A<br>A<br>0.25<br>mA<br>D|| |**parameter**|**conditions/description**|**min**||**max**|**units**| |capac|at Vi nom, full load|||3,500|µF| |initial set point accuracy<br>adjustability<br>liner<br>loadr<br>rated<br>max t|at full load, V in min to V in max<br>5 Vdc output model<br>12 Vdc output model<br>15 Vdc output model<br>24 Vdc output model<br>24 Vdc output model (PDRC-75-24-2)<br>5<br>12<br>13.5<br>24<br>20<br>5 Vdc output model (5.5 Vdc)<br>12 Vdc output model (14.0 Vdc)<br>15 Vdc output model (16.5 Vdc)<br>24 Vdc output model (28.0 Vdc)<br>TIN|||±1<br>±1<br>±1<br>5.5<br>14<br>16.5<br>28<br>24.2<br>10.5<br>5.1<br>4.5<br>3.6|%<br>%<br>%<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>A<br>A<br>A<br>A| ||24 Vdc output model (PDRC-75-24-2) (24.2 Vdc)|||3.7|A| |start-up time|at Vi nom, full load|||1.0<br>1.5|s<br>s| |rise time|at Vi nom, full load|||150<br>500|ms<br>ms| ||5, 12 Vdc output models||||| ||at 115 Vac, full load|16|||ms| |hold-up time|at 230 Vac, full load<br>15, 24 Vdc output models|60|||ms| ||at 115 Vac, full load|12|||ms| ||at 230 Vac, full load|60|||ms| |fall time|at Vi nom, full load|||150|ms| |transi||||2|ms| |switc|at Vi nom, full load|35||45|kHz| |temp||||±0.03|1°C| ||at Vi nom, full load, for 1 second||||| ||5 Vdc output model|7.5|||Vdc| |power back immunity|12 Vdc output model|18|||Vdc| ||15 Vdc output model|22|||Vdc| ||24 Vdc output model|35|||Vdc| ||5 Vdc output model|3.5||4.5|Vdc| |DC ON indicator threshold at|12 Vdc output model|9.0||10.8|Vdc| |start-up (GREEN)|15 Vdc output model|11.0||13.5|Vdc| ||24 Vdc output model|19.2||21.6|Vdc| ||5 Vdc output model|3.5||4.5|Vdc| |DC LOW indicator threshold|12 Vdc output model|9.0||10.8|Vdc| |after start-up (RED)|15 Vdc output model|11.0||13.5|Vdc| ||24 Vdc output model|19.2||21.6|Vdc| **cui** .com Additional Resources: Product Page **date** 02/21/2022 **page** 3 of 6 **CUI Inc SERIES:** PDRC-75 **DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY ## **PROTECTIONS** |**parameter**||**conditions/description**|**min**|typ|**max**|**units**| |---|---|---|---|---|---|---| |||at Vi nom, full load, auto recovery||||| |short circuit protection<br>over<br>over||5 Vdc output model<br>12 Vdc output model<br>15 Vdc output model<br>24 Vdc output model<br>24 Vdc output model (PDRC-75-24-2)<br>24 Vdc output model (PDRC-75-24-2)<br>all other models<br>fold forward|5.75<br>15<br>18<br>30<br>24.5<br>102<br>110||6.5<br>16.5<br>20<br>33<br>25.5<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>Vdc<br>108<br>150<br>%<br>%<br>D|| |**SAFETY & COMPLIANCE**||||||| |**parameter**||**conditions/description**|**min**||**max**|**units**| |input to output for 1 minute<br>3,000<br>4,242<br>Vac<br>Vdc<br>isolation resistance<br>input to output at 500 Vdc<br>100<br>isolati~~a~~||||||| |safety|5|UL 508, UL 1310, UL/EN 62368-1||||| |safety class||class I||||| |||EN 55032 Class B, EN 55024, ENV 50204,||||| |||EN 61204-3, EN 61000-3-2, EN 61000-3-3,||||| |EMI/EMC||EN 61000-6-2, EN 61000-6-3, EN 61000-4-2,||||| |||EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,||||| |||EN 61000-4-6, EN 61000-4-8, EN 61000-4-11||||| |pollut||2||||| |degre||IP20||||| |||5 Vdc output model||610,000||hours| |MTBF||12 Vdc output model<br>15 Vdc output model||578,000<br>581,000||hours<br>hours| |||24 Vdc output model||554,000||hours| |||24 Vdc output model (PDRC-75-24-2)||583,000||hours| |RoHS||yes||||| ## **ENVIRONMENTAL** |**parameter**|**conditions/description**|**min**|**max**|**units**| |---|---|---|---|---| |opera||-40|71|Cc| |stora||-40|85|Cc| |humidity||20|95|%| |altitude|IEC 60068-2-13||4,850|m| |vibrat||||| ||axis)|||| |shock|meets IEC 60068-2-27 (15 G, 11 ms, 3 axis, 6<br>faces, 3 times for each face)|||| **cui** .com Additional Resources: Product Page **CUI Inc SERIES:** PDRC-75 **DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY **date** 02/21/2022 **page** 4 of 6 ~~a~~ **==> picture [563 x 552] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL<br>te parameter conditions/description min max units<br>dimensions 91.00 x 90.00 x 57.00 (3.58 x 3.54 x 2.24 inches) mm<br>material plastic<br>380<br>wet<br>wlinmg<br>input/output connector<br>MECHANICAL DRAWING<br>units: mm [inch] 90.00<br>13.54)<br>tolerance:<br>—<br>unless otherwise noted<br>0aii 0<br>CON 45.00 [1.77]<br>Function<br>aman 1 [J V- _ ne<br>2 V-<br>3 V+<br>4 V+ roa) ao) A<br>ee mj | econ | [|| = | a<br>5 L ° A al of x<br>6 N<br>a — - ee—————— lein ee= = e =|“| O|¢ un<br>ae)LON Fl a =<br>DIN RAIL<br>Cable<br>2)<br>wrens |<br> 7 mm<br>stipteng fo<br>6 lb·in<br>Screwtorg |<br>Position Vertical<br>clearance on all sides<br>[cong |<br>ONTINUE<br>**----- End of picture text -----**<br> **cui** .com **==> picture [560 x 752] intentionally omitted <==** **----- Start of picture text -----**<br> Additional Resources: Product Page<br>CUI Inc SERIES: | PDRC-75 | DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY date 02/21/2022 | page 5 of 6<br>DERATING CURVES<br>TEMPERATURE DERATING CURVE<br>120<br>S 100 Key<br>LL ; CC<br>wo 75 1 5 Vdc output model<br>3 62.5 ----|.---}--- |---| iJ<br>o , ' all other models<br>a 40<br>$s<br>oO 20<br>210 -20 0 20 5661 7180 100<br>Operating Temperature (C°)<br>EFFICIENCY CURVES<br>EFFICIENCY VS OUTPUT LOAD<br>(PDRC-75-24)<br>90<br>89<br>2 87 —<br>> 86 230 Vac<br>Y 85<br>2 84 115 Vac<br>ba= 8382<br>81<br>80<br>79<br>10 25 50 75 100<br>Output Current (%)<br>CURRENT LIMITED CURVE<br>TYPICAL OVER CURRENT PROTECTION CURVE<br>(PDRC-75-24)<br>125<br>¥ 100 Key<br>o ———<br>& 75 230 Vac<br>‘o<br>> 115 Vac<br>= 50<br>=<br>6 [25]<br>0<br>100 110 120 130 140 150 160 170<br>Output Power (%)<br>cui .com<br>DISCONTINUED<br>**----- End of picture text -----**<br> Additional Resources: Product Page **date** 02/21/2022 **page** 6 of 6 **CUI Inc SERIES:** PDRC-75 **DESCRIPTION:** AC-DC DIN RAIL POWER SUPPLY ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|06/17/2019| |1.01||08/04/2020| |1.02|safetymarks updated|04/27/2021| |1.03||02/21/2022| ## 20050 SW SWOR112th 112th Ave. Fax 503.612.2383 **cui** .com techsupport@cui.com **Headquarters** Tualatin,20050 SW SWOR112th **800.275.4899**
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →