NKO4M-L-0-2
FIBRE OPTIC CABLE, LC-LC, MM, 2M
- Manufacturer: NEUTRIK
- Product type: Fiber Optic Lead Assemblies
- Fibre Type: Multimode
- No. of Fibres: 4Fibres
- Product Range: opticalCON QUAD LITE
- Lead Length - Metric: 2m
- Fibre Optic Connector A: LC
- Fibre Optic Connector B: LC
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 265.15 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **opticalCON**
##
**==> picture [78 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
SETTING<br>STANDARDS<br>**----- End of picture text -----**<br>
_**2**_
**PAGE**
## **Content**
|**Introduction****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4_**|
|---|
|**opticalCON Design Criteria****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5_**|
|**opticalCON ADVANCED / LITE****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6_**|
|**opticalCON Chassis****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7_**|
|**opticalCON Mobile Field Cables****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8_**|
|**opticalCON Custom Cable Assembly****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10_**|
|**opticalCON ADVANCED Cable Connectors****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12_**|
|**_Features & Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13_**|
|**_opticalCON DUO ADVANCED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14_**|
|**_opticalCON QUAD ADVANCED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16_**|
|**_opticalCON MTP_**<br>**_® 12 ADVANCED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18_**|
|**_opticalCON MTP_**<br>**_® 24 ADVANCED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20_**|
|**_opticalCON SPLIT & POWER SPLIT Cables . . . . . . . . . . . . . . . . . . . . . . . . . . 22_**|
|**_Breakout Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24_**|
|**_Accessories for opticalCON ADVANCED . . . . . . . . . . . . . . . . . . . . . . . . . . . 25_**|
|**opticalCON LITE Cable Connectors****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26_**|
|**_Features & Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27_**|
|**_opticalCON DUO LITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28_**|
|**_opticalCON QUAD LITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30_**|
|**_opticalCON MTP_**<br>**_® 12 LITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32_**|
|**_opticalCON MTP_**<br>**_® 24 LITE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34_**|
|**opticalCON ADVANCED Chassis Connectors****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36_**|
|**_Features & Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37_**|
|**_opticalCON DUO ADVANCED Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38_**|
|**_opticalCON QUAD ADVANCED Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40_**|
|**_opticalCON MTP_**<br>**_® 12 ADVANCED Chassis . . . . . . . . . . . . . . . . . . . . . . . . . 42_**|
|**_opticalCON MTP_**<br>**_® 24 ADVANCED Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . 44_**|
|**_Accessories for Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46_**|
|**opticalCON Coupler****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46_**|
|**opticalCON Transceiver Adapter****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47_**|
|**opticalCON Breakout Adapter** **_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47_**|
|**opticalCON Breakout Box****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48_**|
|**opticalCON powerMONITOR****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50_**|
|**opticalCON Panel Solutions****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52_**|
|**Fiber Optic Measurement & Cleaning Kit****_. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54_**|
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**3**_
## **The applications for fiber are extensive**
_**A few years ago, the use of fiber optic cabling in professional AV applications was limited to such special cases as HD broadcast cameras . Since then, the AV industry’s adoption of fiber optics has increased immensely . Today, fiber optics are widely used for digital signal transmission in pro audio, professional broadcast, and the touring / rental industries . As pro audio and broadcast equipment has evolved from analog to digital data transmission, the industry has attempted to adapt connectors originally designed for data communication (e .g . RJ45 connectors for electrical transmission) . Today, that trend continues with fiber optic connectors . However, conventional data communication fiber optic connectors (ST, SC, LC, etc .) have a risk of failure when they are deployed in AV applications . These conventional data connectors are optimized for permanent, one-time connection . They were never designed for mobile applications or to handle high mating cycles in harsh environments . Alternative connectors, originally developed for military applications, have not been cost effective and have been deficient either in regards to dust protection and**_
_**maintenance and/or in their attenuation and return loss characteristics .**_
_**Neutrik understood these deficiencies and solved the various issues associated with mobile fiber optic connectivity when it launched its opticalCON® fiber optic line in 2005 . The opticalCON® design is based on a unique concept which combines low maintenance, high mating cycles, and a safe connection in the field . As a result, opticalCON® has gained wide acceptance in the pro audio and professional broadcast industries . Both well known equipment manufacturers and key industry users have put their trust in opticalCON® for many years .**_
**optical** _**CON®**_
_**4**_
## **optical** _**CON®**_ **Design Criteria**
_**The need for rugged fiber optic connections continues to grow rapidly, driven by such technologies as ultra high definition (UHD) 4K or 8K television signals running at data rates of up to 24 Gb/s . To accommodate these higher bandwidth signals, the Society of Motion Picture & Television Engineers (SMPTE) has standardized opticalCON® connectors as the rugged fiber optic interface for mobile high definition television broadcasting where robust and reliable solutions are required .**_
## **4K8K** SIK
## **SMPTE standard ST2091-1**
_**Neutrik’s opticalCON® system became the fiber optic standard in various markets .**_
**optical** _**CON®**_ **ADVANCED DUO** _**is an LC-based fiber optic connection system which is typically used for equipment connections . With built-in, automatic dust shutters and a rugged housing, the fibers are always dust protected, and high mating cycles in harsh environments are achieved . Compatibility with conventional LC connectors at both the front and the rear of the chassis connectors offers users the choice of using either cost-effective, standard LC patch cables or else ruggedized opticalCON cables .**_
_**Following on the success of opticalCON ADVANCED DUO, the**_ **optical** _**CON®**_ **ADVANCED QUAD** _**series, also an LC-based connector system, doubles the fiber count to offer a rugged point-to-point connection . opticalCON® QUAD has been successfully deployed in applications such as data routing for touring / live rental, including especially OB (outdoor broadcast) applications .**_
**optical** _**CON®**_ **ADVANCED MTP** _**® increases the number of fibers in one connector up to 24 and is the ideal solution for point-to-point multi-fiber signal transmission . As an alternative to opticalCON MTP’s single 12 or 24-fiber connector, Neutrik offers a wide variety of SPLIT cable configuration . opticalCON® SPLIT offers an alternative for users of opticalCON® DUO or QUAD chassis connectors, providing advantages in regards to field assembly and potential repair cost .**_
_**Finally, Neutrik’s**_ **optical** _**CON®**_ **LITE** _**connectors offer a cost effective and lightweight solution . The unique design of opticalCON® LITE’s tactical patch cable allows extreme bending without fiber breakage and absorbs high lateral forces . As a result, the opticalCON® LITE is an ideal choice for such permanent and semi-permanent installations as server rooms, patch fields, and indoor cabling .**_
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**5**_
## **optical** _**CON®**_ **Cable Connectors**
**optical** _**CON ®**_ **LITE optical** _**CON ®**_ **ADVANCED**
_—
_**6**_
## **optical** _**CON®**_ **Chassis Connectors**
## **optical** _**CON ®**_ **DUO**
**2-channel fiber optic connection system**
**optical** _**CON ®**_ **QUAD**
**4-channel fiber optic connection system**
**optical** _**CON ®**_ **MTP** _**®**_ **12**
**12-channel fiber optic connection system**
**optical** _**CON ®**_ **MTP** _**®**_ **24**
**24-channel fiber optic connection system**
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**7**_
## **optical** _**CON®**_ **Mobile Field Cable Range**
## **ADVANCED Cable**
## **optical** _**CON**_ **DUO**
_**Rugged and lightweight 2-channel mobile field cable, excellent cable retention due to aramid yarn, black PUR outer jacket, available in multi- and single mode (PC or APC), military approved .**_ |
## **optical** _**CON**_ **DUO X-TREME**
_**2-channel X-TREME cable offering a cut-proof and rodent resistant double jacket glass yarn armoured cable construction, excellent cable retention due to aramid yarn, black PUR outer jacket .**_ |
## **optical** _**CON**_ **DUO ARMORED**
_**Extra rugged and lightweight stainless steel, jacket absorbs leteral forces up to 200 kg/cm[2] . Ultra flexible due to the special spring shape construction, available in multi- and single mode (PC or APC) .**_
## **optical** _**CON**_ **DUO HYBRID**
_**Extra rugged hybrid cable with 2 multimode channels and 4 x 0 .75 mm[2] copper conductors, GFK strengh member and aramid yarn as cable retention .**_
## **optical** _**CON**_ **DUO SMPTE**
_**SMPTE cable with 2 single mode channels (PC or APC), 2 x AWG 24 and 4 x AWG 20 stranded copper conductors, overall copperbraided shield and stainless steel strength member, 120 kg/km .**_
## **optical** _**CON**_ **DUO LOW VOLTAGE HYBRID**
**==> picture [176 x 298] intentionally omitted <==**
**----- Start of picture text -----**<br>
2M / 2S (A)<br>Oa<br>X2M / X2S (A)<br>O - 5 ka<br>XX2M / XX2S (A)<br>Oe =z<br>H1<br>S1 (A)<br>S5 (A)<br>**----- End of picture text -----**<br>
_**Ultra flexible, cost effective and lightweight (65 kg/km) low voltage hybrid cable with 2 single mode channels and 2 x AWG 16 copper conductors, aramid yarn cable retention .**_ |
## **optical** _**CON**_ **QUAD**
_**Rugged and lightweight 4-channel mobile field cable, excellent cable retention due to aramid yarn, black PUR outer jacket, available in multi- and single mode (PC or APC) .**_
## **optical** _**CON**_ **QUAD X-TREME**
**==> picture [47 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
4M / 4S (A)<br>X4M / X4S (A)<br>**----- End of picture text -----**<br>
_**4-channel X-TREME cable offering a cut-proof and rodent resistant double jacket glass yarn armoured cable construction, excellent cable retention due to aramid yarn, black PUR outer jacket .**_
## **optical** _**CON**_ **QUAD ARMORED**
**XX4M / XX4S (A)**
_**Extra rugged and lightweight stainless steel jacket absorbs lateral forces of 200 kg/cm[2] . Ultra flexible due to the special spring shape construction, available in multi- and single mode (PC or APC) .**_ |
_—_
_**8**_
## **optical** _**CON**_ **MTP** _**[® ]**_ **12 & SPLIT**
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
12M / 12S (A)<br>**----- End of picture text -----**<br>
_**Rugged and lightweight 12-channel mobile field cable, excellent cable retention due to aramid yarn, black PUR outer jacket, available in multimode PC and singlemode APC .**_
## **optical** _**CON**_ **MTP** _**[® ]**_ **24 & SPLIT**
**==> picture [46 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
24M / 24S (A)<br>**----- End of picture text -----**<br>
_**24-channel mobile field cable with excellent cable PUR outer jacket, available in multimode PC and singlemode APC .**_ ;
## **optical** _**CON**_ **MTP** _**[®]**_ **12 X-TREME & SPLIT**
**==> picture [54 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
X12M / X12S (A)<br>**----- End of picture text -----**<br>
_**12-channel X-TREME cable offering a cut-proof and rodent resistant double jacket glass yarn armoured cable construction, excellent cable retention due to aramid yarn, black PUR outer jacket .**_ |
## **optical** _**CON**_ **POWER-SPLIT**
**==> picture [45 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
P8M / P8S (A)<br>**----- End of picture text -----**<br>
_**Extra rugged hybrid cable up to 8 single mode channels and 2 x 1 .5 mm[2] copper conductors, 1 .5 mm[2] shield, 2 opticalCON cable connectors and 1 powerCON cable connector .**_
## **LITE Cable**
## **optical** _**CON**_ **DUO LITE**
**==> picture [44 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
2M-L / 2S (A)<br>**----- End of picture text -----**<br>
_**Rugged and lightweight 2-channel patch cable, excellent cable retention due to aramid yarn, black PVC outer jacket, available in multi- and singlemode (PC or APC), suitable for permanent and temporary instalation .**_
## **optical** _**CON**_ **QUAD LITE**
**==> picture [44 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
4M-L / 4S (A)<br>**----- End of picture text -----**<br>
_**Lightweight tactical patch cable, 4 x 900/125 micron fibers, rugged cable retention due to aramid yarn, black PVC outer jacket, available in multiand singlemode (PC or APC), designed for permanent or semi-permanent installations .**_
## **optical** _**CON**_ **MTP** _**[® ]**_ **12 LITE**
**==> picture [45 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
12M-L / 12SA<br>**----- End of picture text -----**<br>
_**Rugged tactical patch cable, 12x 250/125 micron fibers, aramid yarn for appropriate cable retention, black PVC outer jacket, available in multimode PC and singlemode (APC), suitable for permanent or semi-permanent installations .**_
## **optical** _**CON**_ **MTP** _**[® ]**_ **24 LITE**
**==> picture [45 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
24M-L / 12SA<br>**----- End of picture text -----**<br>
_**Rugged tactical patch cable, 24 x 250/125 micron fibers, aramid yarn for appropriate cable retention, black PVC outer jacket, available in multimode PC and singlemode (APC), suitable for permanent or semi-permanent installations .**_
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**9**_
## **optical** _**CON®**_ **Custom Cable Assembly**
**optical** _**CON ®**_ **ADVANCED 6 5 7 2 1 3 optical** _**CON ®**_ **LITE 2 5 3** .—_ **optical** _**CON ®**_ **Split 5 6 7 6 8 9 2 4** Wi _**10**_
**==> picture [16 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
1<br>@<br>**----- End of picture text -----**<br>
**Rubber protection cover**
**==> picture [16 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
5<br>@<br>**----- End of picture text -----**<br>
## **Breakout assembly**
_**Noise cancelling rubber protection cover for opticalCON cable connectors, including front housing .**_
**==> picture [5 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
x<br>**----- End of picture text -----**<br>
**2** @ **Custom color coding** _**Color coding ring for opticalCON cable connectors .**_ mrt tet tt ~~a~~ ): **3 Crossed fiber wiring (A-A), (B-B)** ai— _**Neutrik standard: wiring acc . IEC 11801**_
**Standard split length x:** _**DUO/QUAD 30 cm (1 ft .) MTP 12 60 cm (2 ft .) MTP 24 1 m (3 ft .)**_
## e **6**
**Custom cable & Split text labeling**
_**- Custom labeling**_
_**- 1 or 2 lines**_
_**- Split text to color**_
**7** Te **Female assembly on cable drums** _**Cable extention solution eliminating the need for couplers .**_ @
## **8** @
## **4** e
**Power IN / OUT**
_**With the Neutrik powerCON mains connector NAC3MX-W-TOP (IN) / NAC3FX-W-TOP (OUT) .**_
**==> picture [158 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
NAC3MX-W-TOP NAC3FX-W-TOP<br>**----- End of picture text -----**<br>
**Custom split length** _**Standard: length 1 m**_
## **9** e
**==> picture [178 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
Stepped split assembly<br>Standard: equal split length<br>1 m0 .85 m<br>0 .7 m<br>**----- End of picture text -----**<br>
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**11**_
_**12**_
## **Features & Benefits**
LT **Mobile use** | **Rugged** eee **Low maintenance** Po **High performance**
**==> picture [505 x 263] intentionally omitted <==**
**----- Start of picture text -----**<br>
optical CON DUO optical CON QUAD optical CON MTP ® 12 optical CON MTP ® 24<br>Td NKO2S-A* 05 NKO4S-A* 74 NKO12SA* 74 NKO24SA*<br>• 2 fibers • 4 fibers • 12 fibers • 24 fibers<br>• 4 copper contacts<br>**----- End of picture text -----**<br>
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**13**_
## **optical** _**CON®**_ **DUO ADVANCED**
## **Cable Connector Assembly**
**==> picture [138 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
NKO2S-A* NKO2S-S5-A*<br>**----- End of picture text -----**<br>
- _**Ruggedized and dirt-protected 2-channel fiber optic connection system**_
- _**Cable connector features rugged metal housing and heavy-duty cable retention**_
- _**Automatic sealing shutter with silicone gasket to protect the LC’s**_
- _**Dust and water resistant according to IP65 in mated condition**_
- _**Accommodates standard optical LC-Duplex connectors**_
- _**Field repairable**_
- _**Easy to clean, no special tools required**_
- _**Reliable Push-Pull locking mechanism**_
- _**Cable connector comes pre-assembled with a choice of mobile field cables**_
- _**Range of 3 hybrid cables for powered applications:**_
- _**SMPTE cable for indoor UHD camera routing applications[1]**_
- _**Hybrid multimode cable**_
- _**Light weight low voltage camera / SM hybrid cable for ENG / SNG applications**_
- _**1 . . . Not compatible to SMPTE 304M standard . Suitable for indoor (studio) camera links considering specific cond**_ ~~_**itions acc to IEC 60664-1 like pollution degree 1, overvoltage category**_~~ _**1 and rated voltage . For detailed information ask for the White Paper “opticalCON @ SMPTE Indoor Applications” .**_
**==> picture [477 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
166 [6.5"] 178 [7.0"]<br>ee ee<br>— SETTING<br>STANDARDS<br>Ø27.6 [1.1"] Ø33.0 [1.3"]<br>**----- End of picture text -----**<br>
_**14**_
## **Technical Data**
## **Technical Data Optical Cable Connector**
|**_Optical connector_**<br>**_Fiber_**<br> <br>**_Insertion loss_**<br> <br>**_min . Return loss_**<br>**_SM PC > 50 dB_**|**_Optical connector_**<br>**_Multimode, Singlemode PC / APC_**<br>**_< 0 .45 dB / connection_**<br>**_MM PC> 25 dB_**<br>**_SM PC > 50 dB_**|**_LC-Duplex_**<br><br><br><br>|
|---|---|---|
||**_SM APC> 60 dB_**||
|**MECHANICAL**|||
|**_Insertion / withdrawal force_**<br> **_< 45 N_**|||
|**_Lifetime (mating cycles)_**<br>**_> 5’000_**|||
|**_Cable retention force_**<br>**_Fiber only > 500 N_**|||
||**_Hybrid > 500 N_**||
||**_SMPTE > 500 N_**||
|**ELECTRICAL**<br>**_Number of electrical contacts_**||**_4_**|
|**_Rated current_**|**_6 A_**|**_NKO2M-H1_**|
||**_contact 1+4 10 A_**|**_NKO2S(A)-S1_**|
|**_Contact resistance_**|**_Contact resistance_**<br> **_< 7 m_**Ω||
|**_Insulation resistance_**<br>**_- initial: > 10 G_**Ω|||
|**_- after damp heat test: > 1 G_**<br>**_Dielectric strength_**<br>**_Rated voltage _**|**_- after damp heat test: > 1 G_**Ω<br>**_Dielectric strength_**<br> **_1500 V dc_**<br> **_50 V ac_**|<br><br> **_1_**|
|**MATERIAL**|||
|**_Shell_**|**_Zinc diecast (ZnAl4Cu1),_**||
||**_black chrome plating_**||
|**_Insert / Insulation_**|**_Insert / InsulationPolyamid PA 6, PBT 30% GR,_**||
||**_PBT 50% GR_**||
|**_Insert colour_**|**_MM: black, SM PC: blue,_**||
||**_SM APC: green_**||
|**_Contacts_**|**_- male: Brass (CuZn39Pb3)_**||
|**_Contact surface_**|**_Gold(gal 0 .2 µm Au over 2 µm Ni)_**||
|**_Strain relief_**<br>**_Bushing_**<br>**_Boot_**|**_Brass, Ni plated_**<br> **_ZnAI4Cu1_**<br> **_EPDM, rubber boot_**|<br><br>|
|**ENVIRONMENTAL**<br>**_Operating temp ._**<br>**_-40°C to +75°C_**<br>**_Flammability_**<br>**_UL94 HB_**<br>**_Solderability_**<br>**_complies with IEC 68-2-20_**<br>**_Protection class_**<br>**_in mated condition IP65_**||<br><br><br>|
_**1 . . . Not compatible to SMPTE 304M standard . Suitable for indoor (studio) camera links considering specific conditions acc . to IEC 60664-1 like pollution degree 1, overvoltage category 1 and rated voltage . For detailed information ask for the White Paper "opticalCON @ SMPTE Indoor Applications" .**_
## **Technical Data Cables**
|||**2M**|**2S (A)**|**2M-H1**|**2S (A) - S1**|**2S (A) - S5**|**X2M**|**X2S (A)**|**XX2M**|**XX2S (A)**|
|---|---|---|---|---|---|---|---|---|---|---|
|**_Max . number of fibers_**||**_2_**|**_2_**|**_2_**|**_2_**|**_2_**|**_2_**|**_2_**|**_2_**|**_2_**|
|**_Mode - Multimode PC_**|**_- Multimode PC_**||**_-_**||**_-_**|**_-_**||**_-_**||**_-_**|
||**_- Single mode PC / APC_**|**_-_**||**_-_**|||**_-_**||**_-_**||
|**_Fiber_**|**_- 50 / 125-OM3_**||**_-_**||**_-_**|**_-_**||**_-_**||**_-_**|
||**_- 9 / 125-G657A2_**|**_-_**||**_-_**|||**_-_**||**_-_**||
|**_Bend optimized fiber_**||||**_-_**|||||||
|**_Laser optimized fiber_**|||**_N/A_**|**_-_**|**_N/A_**|**_N/A_**||**_N/A_**||**_N/A_**|
|**_Copper wires_**|**_Copper wires_**||||||||||
||**_- AWG 16_**|**_-_**|**_-_**|**_-_**|**_-_**|**_2x_**|**_-_**|**_-_**|**_-_**|**_-_**|
||**_- AWG 18 (0 .75 mm_**<br>**_2)_**|**_-_**|**_-_**|**_4x_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
||**_- AWG 20_**|**_-_**|**_-_**|**_-_**|**_4x_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
||**_- AWG 24_**|**_-_**|**_-_**|**_-_**|**_2x_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Outer shield_**|||||||||||
||**_- Copper braid_**|**_-_**|**_-_**|**_-_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
||**_- Coated glass yarn_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|||**_-_**|**_-_**|
||**_- Stainless steel Jacket_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|||
|**_Strength member_**|||||||||||
||**_- GFK_**|**_-_**|**_-_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
||**_- Stainless Steel_**|**_-_**|**_-_**|**_-_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Cable retention_**|||||||||||
||**_- Aramid yarn_**||||**_-_**||||||
||**_- Crimp type_**|**_-_**|**_-_**|**_-_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Overall diameter_**|**_Overall diameter_**<br>**_(mm) _**|**_5 .0_**|**_5 .0_**|**_8 .9_**|**_9 .2_**|**_7 .3_**|**_9 .2_**|**_9 .2 10 .5 10 .5_**|**_9 .2 10 .5 10 .5_**|**_9 .2 10 .5 10 .5_**|
|**_Jacket - PUR black matte_**|**_- PUR black matte_**||||||||||
|**_Optical connector_**|**_Optical connector_**||||||||||
||**_- LC-Duplex_**||||||||||
||**_- LC based_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Min . bending radius_**<br>**_(cm) _**||**_5 .0_**|**_5 .0_**|**_8 .9 10 .0 7 .5_**|**_8 .9 10 .0 7 .5_**|**_8 .9 10 .0 7 .5_**|**_9 .2_**|**_9 .2 10 .5 10 .5_**|**_9 .2 10 .5 10 .5_**|**_9 .2 10 .5 10 .5_**|
|**_Weight_**|**_(kg / km)_**|**_21_**|**_23_**|**_78_**|**_120_**|**_65_**|**_79_**|**_79_**|**_131 133_**|**_131 133_**|
|**_Attenuation_**<br>**_(dB / km)_**||**_@ 850 nm - 3 .5_**<br>**_@ 1310 nm - 1 .5_**|**_@ 1310 nm - 0 .5_**<br>**_@ 1550 nm - 0 .5_**|**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .7_**|**_@ 1310 nm - 0 .45_**<br>**_@ 1550 nm - 0 .5_**|**_@ 1310 nm - 0 .5_**<br>**_@ 1550 nm - 0 .5_**|**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .5_**|**_@ 1310 nm - 0 .35_**<br>**_@ 1550 nm - 0 .21_**|**_@ 850 nm - 3 .5_**<br>**_@ 1300 nm - 1 .5_**|**_@ 1310 nm - 0 .5_**<br>**_@ 1550 nm - 0 .5_**|
|**_Bandwidth_**<br>**_(MHz-km)_**||**_@ 850 nm > 1500_**<br>**_@ 1310 nm > 500_**||**_@ 850 nm > 500_**<br>**_@ 1300 nm > 500_**|||**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**||**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**||
|**_Refraction index_**<br>**_Power solution 240V ac / 16A_**||**_-_**<br>**_@ 850 nm - 1 .483_**<br>**_@ 1310 nm - 1 .479_**|**_-_**<br>**_@ 1310 nm - 1 .458_**<br>**_@ 1550 nm - 1 .458_**|**_-_**<br>**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_-_**<br>**_@ 1310 nm - 1 .468_**<br>**_@ 1550 nm - 1 .468_**|**_-_**<br>**_@ 1310 nm - 1 .458_**<br>**_@ 1550 nm - 1 .458_**|**_-_**<br>**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_-_**<br>**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|**_-_**<br>**_@ 850 nm - 1 .483_**<br>**_@ 1310 nm - 1 .479_**|**_-_**<br>**_@ 1310 nm - 1 .458_**<br>**_@ 1550 nm - 1 .458_**|
## **Ordering & Packaging options with max. cable length see on the part number generator - www.neutrik.com**
_**-0 . . . Airspool**_ **0 1 2 3 4 5 6** _**-1 . . . opticalCON Case**_ eo e@ oe e. © ©. © _**-2 . . .**_ .| _**Drum Schill GT310 -3 . . . Drum Schill GT380 -4 . . . Drum Schill HT582**_ o@s8s 6 O8 _**-5 . . .**_ . _**Drum Schill GT450 -6 . . . Drum Schill SK4812**_
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**15**_
## **optical** _**CON®**_ **QUAD ADVANCED**
## **Cable Connector Assembly**
**==> picture [270 x 159] intentionally omitted <==**
**----- Start of picture text -----**<br>
a”<br>NKO4S-A*<br>**----- End of picture text -----**<br>
- _**Ruggedized and dirt-protected 4-channel fiber optic connection system**_
- _**For point-to-point multichannel routing**_
- _**Cable connector features rugged all-metal housing and heavy-duty cable retention**_
- _**Innovative special shutter guarantees low maintenance**_
- _**Dust and water resistant according to IP65 in mated condition**_
- _**Easy to clean, no special tools required**_
- _**Reliable Push-Pull locking mechanism**_
- _**Cable connector comes pre-assembled with a choice of mobile field cables**_
- _**Field repairable**_
**==> picture [477 x 55] intentionally omitted <==**
**----- Start of picture text -----**<br>
166 [6.5"] 178 [7.0"]<br>ee ee<br>Ø27.6 [1.1"] Ø33.0 [1.3"]<br>**----- End of picture text -----**<br>
**==> picture [80 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
_ SETTING ——<br>STANDARDS<br>**----- End of picture text -----**<br>
_**16**_
## **Technical Data**
## **Technical Data Optical Cable Connector**
|**_Optical connector_**|**_PC_**|
|---|---|
|**_Fiber_**<br> **_Multimode, Singlemode PC / APC_**<br>**_Insertion loss_**<br> **_< 0 .45 dB / connection_**<br>**_min . Return lossMM PC> 25 dB_**<br>**_SM PC > 50 dB_**|<br><br><br>|
|**_SM APC> 60 dB_**||
|**MECHANICAL**||
|**_Insertion / withdrawal force_**<br> **_< 45 N_**||
|**_Lifetime (mating cycles)_**<br>**_> 5’000_**||
|**_Cable retention force_**<br>**_Fiber only > 500 N_**||
## **MATERIAL**
|**_Shell_**|**_Zinc diecast (ZnAl4Cu1),_**||
|---|---|---|
||**_black chrome plating_**||
|**_Insert / Insulation_**|**_Insert / InsulationPolyamid PA 6, PBT 30% GR,_**||
||**_PBT 50% GR_**||
|**_Insert colour_**|**_MM: black, SM PC: blue,_**||
||**_SM APC: green_**||
|**_Strain relief_**|**_Brass, Ni plated_**||
|**_Bushing_**|**_ZnAI4Cu1_**||
|**_Boot_**|**_EPDM, rubber boot_**||
|**ENVIRONMENTAL**|||
|**_Operating temp ._**|**_-40°C to +75°C_**||
|**_Flammability_**|**_UL94 HB_**||
|**_Protection class_**|**_in mated condition IP65_**||
|**Technical Data Cables**|**Technical Data Cables**|**Technical Data Cables**||||||
|---|---|---|---|---|---|---|---|
|||**4M**|**4S (A)**|**X4M**|**X4S (A)**|**XX4M**|**XX4S (A)**|
|**_Max . number of fibers_**||**_4_**|**_4_**|**_4_**|**_4_**|**_4_**|**_4_**|
|**_Mode - Multimode PC_**|||**_-_**||**_-_**||**_-_**|
|**_- Single mode PC / APC_**|**_- Single mode PC / APC_**|**_-_**||**_-_**||**_-_**||
|**_Fiber_**<br>**_- 50 / 125-OM3_**|||**_-_**||**_-_**||**_-_**|
|**_- 9 / 125-G657A2_**||**_-_**||**_-_**||**_-_**||
|**_Bend optimized fiber_**||||||||
|**_Laser optimized fiber_**|||**_N/A_**||**_N/A_**||**_N/A_**|
|**_Outer shield_**||||||||
|**_- Copper braid_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_- Coated glass yarn_**||**_-_**|**_-_**|||**_-_**|**_-_**|
|**_- Stainless steel Jacket_**||**_-_**|**_-_**|**_-_**|**_-_**|||
|**_Strength member_**||||||||
|**_- GFK_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_- Stainless Steel_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Cable retention_**||||||||
|**_- Aramid yarn_**||||||||
|**_- Crimp type_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Overall diameter_**|**_(mm)_**|**_5 .8_**|**_5 .8_**|**_9 .2_**|**_9 .2_**|**_10 .5_**|**_10 .5_**|
|**_Jacket - PUR black matte_**||||||||
|**_Optical connector_**||||||||
|**_- LC-Duplex_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_- LC based_**||||||||
|**_Min . bending radius_**|**_(cm)_**|**_5 .8_**|**_5 .8_**|**_9 .2_**|**_9 .2_**|**_10 .5_**|**_10 .5_**|
|**_Weight_**<br>**_(kg / km)_**|**_(kg / km)_**|**_31_**|**_31_**|**_88_**|**_88_**|**_141_**|**_141_**|
|**_Attenuation_**<br>**_(dB / km)_**|**_(dB / km)_**|**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .5_**|**_@ 1310 nm - 0 .35_**<br>**_@ 1550 nm - 0 .21_**|**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .5_**|**_@ 1310 nm - 0 .35_**<br>**_@ 1550 nm - 0 .21_**|**_@ 850 nm - 2 5_**<br>**_@ 1300 nm - 0 .5_**|**_@ 1310 nm - 0 .35_**<br>**_@ 1550 nm - 0 .21_**|
|**_Bandwidth_**<br>**_(MHz-km)_**||**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**||**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**||**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**||
|**_Refraction index_**||**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|
## **Packaging options and max. cable length see on the part number generator - www.neutrik.com**
|**_-0 . . ._**|**_-0 . . ._**|**_Airspool_**|
|---|---|---|
|**_-1 . . ._**|**_-1 . . ._**|**_opticalCON Case_**|
|**_-2 . . ._**<br>**_-3 . . ._**|**_-2 . . ._**<br>**_-3 . . ._**<br>0|**_Drum Schill GT310_**<br>**_Drum Schill GT380_**|
|**_-4 . . ._**|**_-4 . . ._**|**_Drum Schill HT582_**|
|**_-5 . . ._**|**_-5 . . ._**<br>:|**_Drum Schill GT450_**|
|**_-6 . . ._**|**_-6 . . ._**|**_Drum Schill SK4812_**|
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**17**_
## **optical** _**CON®**_ **MTP** _**®**_ **12 ADVANCED Cable Connector Assembly**
**==> picture [44 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
NKO12SA-A*<br>**----- End of picture text -----**<br>
- _**Ruggedized and dirt-protected 12-channel fiber optic connection system**_
-
-
- _**For point-to-point multichannel routing based on MTP ® technology**_
- _**Cable connector features rugged metal housing and heavy-duty cable retention**_
- _**Spherical shutter guarantees low maintenance**_
-
-
-
-
-
- _**Dust and water resistant according to IP65 in mated condition**_
- _**Easy to clean, no special tools required**_
- _**Reliable Push-Pull locking mechanism**_
- _**Cable connector comes pre-assembled with a choice of mobile field cables**_
- _**Wiring Type A**_
_**The MTP® is a multichannel fiber optic connector based on MPO (“Multifiber Push On”) technology (IEC-61754-7) . Breakout / Master cables to standard connectors as LC, SC, ST are av**_ ~~_**ailable in va**_~~ _**riou**_ ~~_**s**_~~ _**l**_ ~~_**ength**_~~
**==> picture [477 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
166 [6.5"] 178 [7.0"]<br>ee ee<br>* . . . MTP ® is a<br>_ SETTING ——<br>STANDARDS<br>Ø27.6 [1.1"] Ø33.0 [1.3"]<br>**----- End of picture text -----**<br>
~~_*****_~~ _**. . .**_ ~~_**MTP**_~~ _**®**_ ~~_**is a**_~~ _**trademark of US Conec (www .usconec .com)**_
_**18**_
**==> picture [12 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTP ®<br>**----- End of picture text -----**<br>
## **Technical Data**
|**Technical Data Optical Cable Connector**|**Technical Data Optical Cable Connector**|||
|---|---|---|---|
|**_Optical connector_**|**_Optical connector_**|**_MTP_**|**®**|
|||**_female_**||
|**_Fiber_**<br> <br>**_Insertion loss_**<br> <br>**_min . Return loss_**|**_Multimode, Singlemode APC_**<br>**_< 0 .9 dB / connection_**<br>**_MM PC> 25 dB_**|<br><br>||
||**_SM APC> 60 dB_**|||
|**MECHANICAL**<br>**_Wiring_**<br>**_Type A_**|**_Type A_**|||
|**_Insertion / withdrawal force_**<br> **_< 45 N_**<br>**_Lifetime (mating cycles)_**<br>**_> 2’500_**<br>**_Cable retention force_**<br>**_Fiber only > 500 N_**||<br><br>||
|**MATERIAL**||||
|**_Shell_**<br>|**_Zinc diecast (ZnAl4Cu1),_**|||
|**_black chrome plating_**|**_black chrome plating_**|||
|**_Insert / Insulation_**<br>**_POM, PC, PEI_**|**_Insert / InsulationPA 6_**<br>**_POM, PC, PEI_**|||
|**_Insert colour_**<br>|**_MM: black, SM PC: blue,_**|||
|**_SM APC: green_**|**_SM APC: green_**|||
|**_Strain relief_**<br>|**_Brass, Ni plated_**|||
|**_Bushing_**<br>|**_ZnAI4Cu1_**|||
|**_Boot_**<br>|**_EPDM, rubber boot_**|||
|**ENVIRONMENTAL**||||
|**_Operating temp ._**|**_-40°C to +75°C_**|||
|**_Flammability_**<br>**_Protection class_**|**_UL94 HB_**<br>**_in mated condition IP65_**|<br>||
## **Technical Data Cables**
|||**12M**|**12SA**|**X12M**|**X12SA**|
|---|---|---|---|---|---|
|**_Max . number of fibers_**||**_12_**|**_12_**|**_12_**|**_12_**|
|**_Mode - Multimode PC_**|||**_-_**||**_-_**|
|**_- Single mode PC / APC_**|**_- Single mode PC / APC_**|**_-_**||**_-_**||
|**_Fiber_**<br>**_- 50 / 125-OM3_**|||**_-_**||**_-_**|
|**_- 9 / 125-G657A2_**||**_-_**||**_-_**||
|**_Bend optimized fiber_**||||||
|**_Laser optimized fiber_**|||**_N/A_**||**_N/A_**|
|**_Outer shield_**||||||
|**_- Copper braid_**||**_-_**|**_-_**|**_-_**|**_-_**|
|**_- Coated glass yarn_**||**_-_**|**_-_**|||
|**_- Stainless steel Jacket_**||**_-_**|**_-_**|**_-_**|**_-_**|
|**_Strength member_**||||||
|**_- GFK_**||**_-_**|**_-_**|**_-_**|**_-_**|
|**_- Stainless Steel_**||**_-_**|**_-_**|**_-_**|**_-_**|
|**_Cable retention_**||||||
|**_- Aramid yarn_**||||||
|**_- Crimp type_**||**_-_**|**_-_**|**_-_**|**_-_**|
|**_Overall diameter_**|**_(mm)_**|**_8 .2_**|**_8 .2_**|**_10 .9_**|**_10 .9_**|
|**_Jacket - PUR black matte_**||||||
|**_Optical connector_**||||||
|**_- LC-Duplex_**||**_-_**|**_-_**|||
|**_- LC based_**||||||
|**_Min . bending radius_**|**_(cm)_**|**_8 .2_**|**_8 .2_**|**_10 .9_**|**_10 .9_**|
|**_Weight_**<br>**_(kg / km)_**|**_(kg / km)_**|**_60_**|**_60_**|**_103_**|**_103_**|
|**_Attenuation_**<br>**_(dB / km)_**|**_(dB / km)_**|**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .5_**|**_@ 1310 nm - 0 .5_**<br>**_@ 1550 nm - 0 .3_**|**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .5_**|**_@ 1310 nm - 0 .5_**<br>**_@ 1550 nm - 0 .3_**|
|**_Bandwidth_**<br>**_(MHz-km)_**<br>**_Refraction index_**||**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**<br>**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**<br>**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|
## **Packaging options and max. cable length see on the part number generator - www.neutrik.com**
|**_-0 . . ._**|**_Airspool_**|
|---|---|
|**_-1 . . ._**|**_opticalCON Case_**|
|**_-2 . . ._**|**_Drum Schill GT310_**|
|**_-3 . . ._**|**_Drum Schill GT380_**|
|**_-4 . . ._**|**_Drum Schill HT582_**|
|**_-5 . . ._**|**_Drum Schill GT450_**|
|**_-6 . . ._**|**_Drum Schill SK4812_**|
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**19**_
## **optical** _**CON®**_ **MTP** _**®**_ **24 ADVANCED Cable Connector Assembly**
## **NKO24M-A***
- _**Ruggedized and dirt-protected 24-channel fiber optic connection system**_
-
-
- _**For point-to-point multichannel routing based on MTP ® technology**_
- _**Cable connector features rugged metal housing and heavy-duty cable retention**_
- _**Spherical shutter guarantees low maintenance**_
-
-
-
-
- _**Dust and water resistant according to IP65 in mated condition**_
- _**Easy to clean, no special tools required**_
- _**Reliable Push-Pull locking mechanism**_
- _**Cable connector comes pre-assembled with a choice of mobile field cables**_
- _**Wiring Type A**_
**==> picture [477 x 173] intentionally omitted <==**
**----- Start of picture text -----**<br>
166 [6.5"] 178 [7.0"]<br>ee ee<br>* . . . MTP ® is a<br>_ SETTING ——<br>STANDARDS<br>Ø27.6 [1.1"] Ø33.0 [1.3"]<br>**----- End of picture text -----**<br>
~~_*****_~~ _**. . .**_ ~~_**MTP**_~~ _**®**_ ~~_**is a**_~~ _**trademark of US Conec (www .usconec .com)**_
_**20**_
**==> picture [12 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTP ®<br>**----- End of picture text -----**<br>
## **Technical Data**
|**Technical Data Optical Cable Connector**|**Technical Data Optical Cable Connector**|||
|---|---|---|---|
|**_Optical connector_**|**_Optical connector_**|**_MTP_**|**®**|
|||**_female_**||
|**_Fiber_**<br>|**_Multimode, Singlemode APC_**|||
|**_Insertion loss_**<br> <br>**_min . Return loss_**|**_< 0 .9 dB / connection_**<br>**_MM PC> 25 dB_**|<br>||
||**_SM APC> 60 dB_**|||
|**MECHANICAL**<br>**_Wiring_**<br>**_Type A_**|**_Type A_**|||
|**_Insertion / withdrawal force_**<br> **_< 45 N_**<br>**_Lifetime (mating cycles)_**<br>**_> 2’500_**<br>**_Cable retention force_**<br>**_Fiber only > 500 N_**||<br><br>||
|**MATERIAL**||||
|**_Shell_**<br>|**_Zinc diecast (ZnAl4Cu1),_**|||
|**_black chrome plating_**|**_black chrome plating_**|||
|**_Insert / Insulation_**<br>**_POM, PC, PEI_**|**_Insert / InsulationPA 6_**<br>**_POM, PC, PEI_**|||
|**_Insert colour_**<br>|**_MM: black, SM PC: blue,_**|||
|**_SM APC: green_**|**_SM APC: green_**|||
|**_Strain relief_**<br>|**_Brass, Ni plated_**|||
|**_Bushing_**<br>|**_ZnAI4Cu1_**|||
|**_Boot_**<br>|**_EPDM, rubber boot_**|||
|**ENVIRONMENTAL**||||
|**_Operating temp ._**|**_-40°C to +75°C_**|||
|**_Flammability_**<br>**_Protection class_**|**_UL94 HB_**<br>**_in mated condition IP65_**|<br>||
## **Technical Data Cables**
|||**24M**|**24SA**|
|---|---|---|---|
|**_Max . number of fibers_**||**_24_**|**_24_**|
|**_Mode - Multimode PC_**|||**_-_**|
|**_- Single mode PC / APC_**|**_- Single mode PC / APC_**|**_-_**||
|**_Fiber_**<br>**_- 50 / 125-OM3_**|||**_-_**|
|**_- 9 / 125-G657A2_**||**_-_**||
|**_Bend optimized fiber_**||||
|**_Laser optimized fiber_**|||**_N/A_**|
|**_Outer shield_**||||
|**_- Copper braid_**||**_-_**|**_-_**|
|**_- Coated glass yarn_**||**_-_**|**_-_**|
|**_- Stainless steel Jacket_**||**_-_**|**_-_**|
|**_Strength member_**||||
|**_- GFK_**||**_-_**|**_-_**|
|**_- Stainless Steel_**||**_-_**|**_-_**|
|**_Cable retention_**||||
|**_- Aramid yarn_**||||
|**_- Crimp type_**||**_-_**|**_-_**|
|**_Overall diameter_**|**_(mm)_**|**_7 .0_**|**_7 .0_**|
|**_Jacket - PUR black matte_**||||
|**_Optical connector_**||||
|**_- LC-Duplex_**||**_-_**|**_-_**|
|**_- LC based_**||||
|**_Min . bending radius_**|**_(cm)_**|**_8 .2_**|**_8 .2_**|
|**_Weight_**<br>**_(kg / km)_**|**_(kg / km)_**|**_43_**|**_43_**|
|**_Attenuation_**<br>**_(dB / km)_**|**_(dB / km)_**|**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .5_**|**_@ 1310 nm - 0 .5_**<br>**_@ 1550 nm - 0 .3_**|
|**_Bandwidth_**<br>**_(MHz-km)_**<br>**_Refraction index_**||**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**<br>**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|
**==> picture [500 x 90] intentionally omitted <==**
**----- Start of picture text -----**<br>
Packaging options and max. cable length see on the part number generator - www.neutrik.com<br>ee«e 0 1 2 eee 3 4 5 @ 6 -0 . . . -1 . . . | opticalCON CaseAirspool o mccen<br>-2 . . . Drum Schill GT310<br>-3 . . . Drum Schill GT380<br>-4 . . . an Drum Schill HT582 .<br>oe -5 . . . | Drum Schill GT450 ae<br>-6 . . . Drum Schill SK4812<br>**----- End of picture text -----**<br>
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**21**_
## **optical** _**CON®**_ **Split Cables SPLIT & POWER SPLIT Cables**
**==> picture [100 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
Zw<br>NKOY*<br>1 m<br>**----- End of picture text -----**<br>
- _**opticalCON multichannel solution based on opticalCON DUO, QUAD or MTP® connectors**_
- _**Maximum flexibility, combining up to 12-channel**_
- _**Custom configurations available**_
- _**1m SPLIT fanout**_
- _**Color coding for channel identification**_
- _**Field assembly possible**_
- _**XTREME version available**_
**==> picture [219 x 145] intentionally omitted <==**
**----- Start of picture text -----**<br>
POWER-<br>—_<br>NKOYP*<br>1 m<br>**----- End of picture text -----**<br>
- _**2-, 4-, 6- and 8-channel assembly available**_
- _**Custom made cable, optimized for ENG / SNG applications**_
-
-
-
- _**Hybrid fiber / copper solution**_
- _**Custom Configurations**_
- _**Up to 240 V ac (16 A) power transportation possible**_
——_
_**22**_
## **Technical Data**
|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|**Technical Data Cables**<br>**Technical Data Optical Cable Connector**<br>~~es~~|
|---|---|---|---|---|---|---|---|---|
|**_Optical connector_**|**_PC_**||||||||
|**_Fiber_**<br> **_Multimode, Singlemode PC / APC_**<br>**_Insertion loss_**<br> **_< 0 .45 dB / connection_**<br>**_min . Return lossMM PC> 25 dB_**<br>**_SM PC > 50 dB_**|<br><br><br>||**12M**|**12S (A)**|**X12M**|**X12S (A)**|**P8M**|**P8S (A)**|
|**_SM APC> 60 dB_**|||||||||
|||**_Max . number of fibers_**|**_12_**|**_12_**|**_12_**|**_12_**|**_8_**|**_8_**|
|**MECHANICAL**||**_Mode - Multimode PC_**||**_-_**||**_-_**||**_-_**|
|**_Insertion / withdrawal force_**<br> **_< 45 N_**<br>**_Lifetime (mating cycles)_**<br>**_> 5’000_**|<br>|**_- Single mode PC / APC_**<br>**_Fiber_**<br>**_- 50 / 125-OM3_**<br>**_- 9 / 125-G657A2_**|**_-_**<br><br>**_-_**|<br>**_-_**<br>|**_-_**<br><br>**_-_**|<br>**_-_**<br>|**_-_**<br><br>**_-_**|<br>**_-_**<br>**_-_**|
|**_Cable retention force_**<br>**_Fiber only > 500 N_**||**_Bend optimized fiber_**|||||||
|||**12M**|**12S (A)**|**X12M**|**X12S (A)**|**P8M**|**P8S (A)**|
|---|---|---|---|---|---|---|---|
|**_Max . number of fibers_**||**_12_**|**_12_**|**_12_**|**_12_**|**_8_**|**_8_**|
|**_Mode - Multimode PC_**|||**_-_**||**_-_**||**_-_**|
|**_- Single mode PC / APC_**||**_-_**||**_-_**||**_-_**||
|**_Fiber_**<br>**_- 50 / 125-OM3_**|||**_-_**||**_-_**||**_-_**|
|**_- 9 / 125-G657A2_**||**_-_**||**_-_**||**_-_**|**_-_**|
|**_Bend optimized fiber_**||||||||
|**_Laser optimized fiber_**|||**_N/A_**||**_N/A_**||**_N/A_**|
|**_Copper wires_**||||||||
|**_- 3 x 1 .5 mm_**<br>**_2_**||**_-_**|**_-_**|**_-_**|**_-_**|||
|**_Outer shield_**||||||||
|**_- Copper braid_**||**_-_**|**_-_**|**_-_**|**_-_**|||
|**_- Coated glass yarn_**||**_-_**|**_-_**|||**_-_**|**_-_**|
|**_- Stainless steel Jacket_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Strength member_**||||||||
|**_- GFK_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_- Stainless Steel_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Cable retention_**||||||||
|**_- Aramid yarn_**||||||||
|**_- Crimp type_**||**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|**_-_**|
|**_Overall diameter_**|**_(mm)_**|**_8 .2_**|**_8 .2_**|**_10 .9_**|**_10 .9_**|**_11 .7_**|**_11 .7_**|
|**_Jacket - PUR black matte_**||||||||
|**_Optical connector_**||||||||
|**_- LC-Duplex_**||**_-_**|**_-_**|||||
|**_- LC based_**||||||||
|**_Min . bending radius_**|**_(cm)_**|**_8 .2_**|**_8 .2_**|**_10 .9_**|**_10 .9_**|**_12 .1_**|**_12 .1_**|
|**_Weight_**<br>**_(kg / km)_**|**_(kg / km)_**|**_60_**|**_60_**|**_103_**|**_103_**|**_138_**|**_138_**|
|**_Attenuation_**<br>**_(dB / km)_**<br>**_Bandwidth_**<br>**_(MHz-km)_**||**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .5_**<br>**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**|**_@ 1310 nm - 0 .5_**<br>**_@ 1550 nm - 0 .3_**|**_@ 850 nm - 2 .5_**<br>**_@ 1300 nm - 0 .5_**<br>**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**|**_@ 1310 nm - 0 .5_**<br>**_@ 1550 nm - 0 .3_**|**_@ 850 nm_**≤**_2 3_**<br>**_@ 1300 nm_**≤**_0 .6_**<br>**_@ 850 nm_**≥ **_1500_**<br>**_@ 1300 nm_**≥ **_500_**|**_@ 1310 nm_**≤**_0 .33_**<br>**_@ 1550 nm_**≤**_0 .19_**|
|**_Refraction index_**||**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|**_@ 850 nm - 1 .482_**<br>**_@ 1300 nm - 1 .477_**|**_@ 1310 nm - 1 .467_**<br>**_@ 1550 nm - 1 .467_**|
|**_Power solution 240V ac / 16A_**||**_-_**|**_-_**|**_-_**|**_-_**|**_*_**|**_*_**|
## **MATERIAL**
|**_Shell_**|**_Zinc diecast (ZnAl4Cu1),_**||
|---|---|---|
||**_black chrome plating_**||
|**_Insert / Insulation_**|**_Insert / InsulationPolyamid PA 6, PBT 30% GR,_**||
||**_PBT 50% GR_**||
|**_Insert colour_**|**_MM: black, SM PC: blue,_**||
||**_SM APC: green_**||
|**_Strain relief_**|**_Brass, Ni plated_**||
|**_Bushing_**|**_ZnAI4Cu1_**||
|**_Boot_**|**_EPDM, rubber boot_**||
|**ENVIRONMENTAL**|||
|**_Operating temp ._**|**_-40°C to +75°C_**||
|**_Flammability_**|**_UL94 HB_**||
|**_Protection class_**|**_in mated condition IP65_**||
## **ENVIRONMENTAL**
_*** Cable must be unreeled completely before use!**_
**Packaging options and max. cable length see on the part number generator - www.neutrik.com 0 1 2 3 4 5 6** _**-0 . . . Airspool -1 . . . opticalCON Case -2 . . . Drum Schill GT310 -3 . . . Drum Schill GT380 -4 . . . Drum Schill HT582 -5 . . . Drum Schill GT450**_ ~~2~~ 4608 _**-6 . . . Drum Schill SK4812**_ ~~@~~
|**_-0 . . ._**<br>**_-1 . . ._**<br>**_-2 . . ._**<br>**_-3 . . ._**<br>**_-4 . . ._**<br>**_-5 . . ._**<br>**_-6 . . ._**|**_Airspool_**<br>**_opticalCON Case_**<br>**_Drum Schill GT310_**<br>**_Drum Schill GT380_**<br>**_Drum Schill HT582_**<br>**_Drum Schill GT450_**<br>**_Drum Schill SK4812_**|
|---|---|
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**23**_
## **Ordering Information**
## **Breakout Adapter**
**==> picture [511 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
a MTP ® Breakout / Master Cable<br>**----- End of picture text -----**<br>
**==> picture [158 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Custom MTP ® patch / master cable (LC / ST / SC)<br>**----- End of picture text -----**<br>
- _**Low loss breakout cable**_
- _**Grade A premium ferrules**_
- _**LC (APC) / SC, ST breakout connector available**_
- _**Standard split length: 61 cm**_
- _**High performance USCONEC Elite[®] Male MTP[®] ferrule**_
- _**Interferometer measurement to guarantee high ferrule performance**_
_**High performance MTP[®] breakout cable for permanent and temporary installations . Standard premium grade A LCs (single-mode PC; multimode PC) guarantee low insertion loss values . 61 cm long fan-out for easy fiber breakout to any opticalCON DUO or QUAD chassis .**_
**==> picture [455 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|NKOB12SA-A-0-**|MTP® 12 / LC - patch cable, Singlemode PC|
|NKOB12M-A-0-**|MTP® 12 / LC - patch cable, Multimode PC|
|NKOB24SA-A-0-**|MTP® 24 / LC - patch cable, Singlemode PC|
|NKOB24M-A-0-**|MTP® 24 / LC - patch cable, Multimode PC|
|Attribute:|
|BO [ ]|. . . breakout connectors (ST, SC), APC on request|
|*|. . . Fiber optic transmission parameters exceeding standard quality, suitable for measurement applications .|
|Notice:|Standard for out configuration comes with LC (PC) connectors .|
**----- End of picture text -----**<br>
_**24**_
## **Accessories**
## **Accessories for Cable Connector**
**SCNO*X-A**
**SCNO*X-A-NC NAO4ML-A**
## **NOR-***
|**_SCNO*X-A_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|**_Rubber coated protection cover for opticalCON cable connectors, including black chrome front housing_**|
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|**_SCNO*X-A-NC_**|**_Light weight noise cancelling rubber protection cover for opticalCON cable connectors, including front housing_**|||||||||||||||||||
|**_SCNO*X-R1)_**|**_Rubber coated protection cover for opticalCON cable connectors, ruthenium plated front housing,_**|||||||||||||||||||
||**_upgrade kit old connector_**|||||||||||||||||||
|**_NOR-*_**|**_Color coding ring for cable connector chassis_**|||||||||||||||||||
|**_NAO4ML-A_**|**_opticalCON QUAD LOOP connector, multimode_**|||||||||||||||||||
|**_NAO4SL-A_**|**_opticalCON QUAD LOOP connector, singlemode_**|||||||||||||||||||
||**_*: 0- black, 1- brown, 2- red, 3-orange, 4- yellow, 5- green, 6- blue, 7- violet, 8- grey, 9- white_**|||||||||||||||||||
||**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**<br>1a|**0 1 2 3 4 5 6 7 8**<br>a|**0 1 2 3 4 5 6 7 8**<br>ass|**0 1 2 3 4 5 6 7 8**<br>ss||**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 8**|**0 1 2 3 4 5 6 7 89**|
||**_1) : find part numbers on www .neutrik .com_**||||**_: find part numbers on www .neutrik .com_**|||||||||||||||
## **opticalCON Pulling Solutions**
**==> picture [465 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
Single pulling sock Split pulling sock<br>FOPS-SINGLE FOPS-SPLIT<br>~~ —. Application example: FOPS-SPLIT<br>**----- End of picture text -----**<br>
## _**• Pulling sock simplifies installation**_
- _**Pulling force > 100 kg**_
- _**Protects connectors in mated / unmated condition**_
_**FOPS-SPLIT Split cable pulling sock FOPS-SINGLE Single cable pulling sock for DUO / QUAD or MTP® cables .**_
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**25**_
#
_**26**_
**Features & Benefits**
~~a~~ **Small form factor** LT **Tactical patch cable** a **Safe connection** [ **Cost effective** ~~a~~
**==> picture [123 x 35] intentionally omitted <==**
**----- Start of picture text -----**<br>
optical CON DUO LITE<br>SS<br>**----- End of picture text -----**<br>
**==> picture [506 x 259] intentionally omitted <==**
**----- Start of picture text -----**<br>
optical CON DUO LITE optical CON QUAD LITE optical CON MTP ® 12 LITE optical CON MTP ® 24 LITE<br>yw NKO2M-L* ta” NKO4M-L* av NKO12M-L* 3 NKO24M-L*<br>• 2 x 1 .25 mm LC-ferrules • 4 x 1 .25 mm LC-ferrules • 12 fiber - MTP [®] ferrule • 24 fiber - MTP [®] ferrule<br>**----- End of picture text -----**<br>
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**27**_
## **optical** _**CON®**_ **DUO LITE**
## **Cable Connector Assembly**
**NKO2M-L***
-
-
-
- _**2-channel fiber optic connection system**_
- _**Cost optimized fiber connection for semi and permanent installations**_
- _**Waterproof acc . to IP65 safety standard in mated condition**_
- _**Small form factor**_
-
-
-
- _**Push-Pull locking mechanism for save connection**_
- _**Easy to clean, no special tools required**_
- _**Compatible with standard opticalCON DUO chassis NO2-4FDW-A***_
**Tactical Patch Cable** ~~LC~~ _**Conventional patch cables are sensitive in terms of under cutting the minimum bending radius and lateral pressure .**_ **Buffer** _**Neutrik’s tactical patch cables feature unique fiber design**_ **Protection buffer** _**including a protection buffer which allows bendings with minimal radius and increased lateral pressure .**_ **Glass cladding** _**Therefore the tactical patch cables are the right choice for**_ **Glass core** _**permanent or semi-permanent applications .**_ C ~~o~~ a ay EE
—
_**28**_
## **Technical Data**
**==> picture [494 x 328] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Technical Data Optical Cable Connector|Technical Data Cables|
|Optical connector|LC-Duplex|
|Fiber|Multimode, Singlemode PC / APC||
|Insertion loss|< 0 .45 dB / connection||
|min . Return loss|MM PC|[>]|25 dB||
|SM PC > 50 dB||Max . number of fibers|2|2|
|Mode - Multimode PC||-|
|SM APC|[> ]|60 dB||
|- Single mode PC / APC|-||
|MECHANICAL|Fiber|- 50 / 125-OM3||-|
|- 9 / 125-G657A2|-||
|Insertion / withdrawal force|< 45 N||Bend optimized fiber|||
|Lifetime (mating cycles)|> 2’500||Laser optimized fiber||-|
|Cable retention force|Fiber only > 500 N||Cable retention|
|Hybrid > 500 N||- Aramid yarn|||
|SMPTE > 500 N||- Crimp type|-|-|
|Overall diameter|(mm)|3 .0|3 .0|
|MATERIAL|Jacket - PUR black matte|||
|Optical connector|
|Shell|PBT 30% GR||-|-|
|- LC-Duplex|
|Insert / Insulation|PBT 30% GR||- LC based|||
|Strain relief|Brass, Ni plated||
|Min . bending radius|(cm)|3 .0|3 .0|
|Bushing|PA6||Weight|(kg / km)|9|9|
|Boot|EPDM, rubber boot||Attenuation|(dB / km)|@@1300 nm 850 nm|[≤][≤]|3 .0 1 .0|@@1310 nm 1550 nm|[≤][≤]|0 .35 0 .21|
|Split sleeve|Ceramics||
|Bandwidth|(MHz-km)|@@|850 nm 1300 nm|≥≥|1500500|@@|850 nm 1300 nm|≥≥|1500500|
|Refraction index|@850 nm - 1 .481|@1310 nm - 1 .467|
|ENVIRONMENTAL|@1300 nm - 1 .476|@1550 nm - 1 .468|
|Operating temp .|-40°C to +75°C||
|Flammability|UL94 HB||
|Protection class|in mated condition IP65||
**----- End of picture text -----**<br>
**Accessories for Cable Connector**
**SCNKO-L NOR-*** _**SCNKO-L Rubber dirt protection for opticalCON LITE cable connector (spare part) NOR-* Color coding ring for cable connector chassis *: 0- black, 1- brown, 2- red, 3-orange, 4- yellow, 5- green, 6- blue, 7- violet, 8- grey, 9- white**_ **0 1 2 3 4 5 6 7 8 9** WH” Rm
**Packaging options and max. cable length see on the part number generator - www.neutrik.com**
**==> picture [258 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
@ 0 -0 . . . Only airspool packaging available<br>**----- End of picture text -----**<br>
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**29**_
## **optical** _**CON®**_ **QUAD LITE Cable Connector Assembly**
**NKO4M-L***
- _**4-channel fiber optic connection system**_
- _**Waterproof acc . to IP65 safety standard in mated condition**_
- _**Push-pull locking mechanism**_
- _**Recommended for point-to-point connection**_
- _**Easy to clean, no special tools required**_
- _**Tactical patch cable**_
- _**Compatible with standard opticalCON ADVANCED NO4FDW-A chassis**_
**==> picture [478 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
(OS (is<br>ay A<br>_— SETTING<br>STANDARDS<br>Ø27.0 [1.06"] Ø25.5 [1.0"]<br>**----- End of picture text -----**<br>
_**30**_
## **Technical Data**
**==> picture [494 x 328] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|Technical Data Optical Cable Connector|Technical Data Cables|
|Optical connector|PC|
|Fiber|Multimode, Singlemode PC / APC||
|Insertion loss|< 0 .45 dB / connection||
|min . Return loss|MM PC|[>]|25 dB||
|SM PC > 50 dB||Max . number of fibers|4|4|
|Mode - Multimode PC||-|
|SM APC|[> ]|60 dB||
|- Single mode PC / APC|-||
|MECHANICAL|Fiber|- 50 / 125-OM3||-|
|- 9 / 125-G657A2|-||
|Insertion / withdrawal force|< 45 N||Bend optimized fiber|||
|Lifetime (mating cycles)|> 2’500||Laser optimized fiber||-|
|Cable retention force|Fiber only > 500 N||Cable retention|
|Hybrid > 500 N||- Aramid yarn|||
|SMPTE > 500 N||- Crimp type|-|-|
|Overall diameter|(mm)|3 .5|3 .5|
|MATERIAL|Jacket - PUR black matte|||
|Optical connector|
|Shell|PBT 30% GR||-|-|
|- LC-Duplex|
|Insert / Insulation|PBT 30% GR||- LC based|||
|Strain relief|Brass, Ni plated||
|Min . bending radius|(cm)|3 .5|3 .5|
|Bushing|PA6||Weight|(kg / km)|14|12|
|Boot|EPDM, rubber boot||Attenuation|(dB / km)|@@1300 nm 850 nm|[≤][≤]|3 .0 1 .0|@@|1310 nm 1550 nm|[≤][≤]|3 .0 1 .0|
|Split sleeve|Ceramics||
|Bandwidth|(MHz-km)|@@|850 nm 1300 nm|≥≥|1500500|@@|850 nm 1300 nm|≥≥|1500500|
|Refraction index|@|850 nm - 1 .481|@|850 nm - 1 .481|
|ENVIRONMENTAL|@|1300 nm - 1 .476|@|1300 nm - 1 .476|
|Operating temp .|-40°C to +75°C||
|Flammability|UL94 HB||
|Protection class|in mated condition IP65||
**----- End of picture text -----**<br>
**Accessories for Cable Connector**
**SCNKO-L NOR-*** _**SCNKO-L Rubber dirt protection for opticalCON LITE cable connector (spare part) NOR-* Color coding ring for cable connector chassis *: 0- black, 1- brown, 2- red, 3-orange, 4- yellow, 5- green, 6- blue, 7- violet, 8- grey, 9- white**_ **0 1 2 3 4 5 6 7 8 9** ~~On~~ eee | **Packaging options and max. cable length see on the part number generator - www.neutrik.com 0** _**-0 . . . Only airspool packaging available**_
## **Packaging options and max. cable length see on the part number generator - www.neutrik.com**
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**31**_
## **optical** _**CON®**_ **MTP** _**®**_ **12 LITE Cable Connector Assembly**
**NKO12SA-L***
- _**12-channel MTP[®] based fiber optic connection system**_
- _**Waterproof acc . to IP65 safety standard in mated condition**_
- _**Recommended for multi-signal transmission**_
- _**Push-pull locking mechanism**_
- _**Custom color coding**_
- _**Rugged housing**_
- _**Rubber protection cap**_
- _**Compatible with standard opticalCON ADVANCED NO12FDW-A chassis**_
**==> picture [229 x 195] intentionally omitted <==**
**----- Start of picture text -----**<br>
aS we<br>o F<br>a<br>SETTING<br>STANDARDS<br>Ø27.0 [1.06"]<br>**----- End of picture text -----**<br>
**==> picture [250 x 110] intentionally omitted <==**
**----- Start of picture text -----**<br>
E T S=<br>EE * . . . MTP ® is a trademark of US Conec (www .usconec .com)<br>Ø25.5 [1.0"]<br>**----- End of picture text -----**<br>
_**32**_
**==> picture [12 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTP ®<br>**----- End of picture text -----**<br>
## **Technical Data**
**==> picture [232 x 320] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Technical Data Optical Cable Connector|
|Optical connector|MTP|®|ELITE|
|female|
|Fiber|Multimode, Singlemode APC||
|Insertion loss|< 0 .9 dB / connection||
|min . Return loss|MM PC|[>]|25 dB||
|SM APC|[> ]|60 dB||
|MECHANICAL|
|Insertion / withdrawal force|< 45 N||
|Lifetime (mating cycles)|> 1’500||
|Cable retention force|Fiber only > 500 N||
|Hybrid > 500 N||
|SMPTE > 500 N||
|MATERIAL|
|Shell|PBT 30% GR||
|Insert / Insulation|PC, PEI||
|Strain relief|Brass, Ni plated||
|Bushing|PA6||
|Boot|EPDM, rubber boot||
|ENVIRONMENTAL|
|Operating temp .|-40°C to +75°C||
|Flammability|UL94 HB||
|Protection class|in mated condition IP65||
**----- End of picture text -----**<br>
## **Technical Data Cables**
**==> picture [247 x 261] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||
|---|---|---|---|---|---|---|---|---|---|
|Max . number of fibers|12|12|
|Mode - Multimode PC||-|
|- Single mode PC / APC|-||
|Fiber|- 50 / 125-OM3||-|
|- 9 / 125-G657A2|-||
|Bend optimized fiber|||
|Laser optimized fiber||-|
|Cable retention|
|- Aramid yarn|||
|- Crimp type|-|-|
|Overall diameter|(mm)|3 .5|3 .5|
|Jacket - PUR black matte|||
|Optical connector|
|-|-|
|- LC-Duplex|
|- LC based|||
|Min . bending radius|(cm)|3 .5|3 .5|
|Weight|(kg / km)|12 .0|12 .0|
|Attenuation|(dB / km)|@@1300 nm 850 nm|[≤][≤]|3 .0 1 .0|@@1310 nm 1550 nm|[≤][≤]|3 .0 1 .0|
|Bandwidth|(MHz-km)|@@|850 nm 1300 nm|≥≥|1500500|@@|850 nm 1300 nm|≥≥|1500500|
|Refraction index|@850 nm - 1 .481|@1310 nm - 1 .481|
|@1550 nm - 1 .476|@1550 nm - 1 .476|
**----- End of picture text -----**<br>
**Accessories for Cable Connector**
**SCNKO-L NOR-*** _**SCNKO-L Rubber dirt protection for opticalCON LITE cable connector (spare part) NOR-* Color coding ring for cable connector chassis *: 0- black, 1- brown, 2- red, 3-orange, 4- yellow, 5- green, 6- blue, 7- violet, 8- grey, 9- white**_ **0 1 2 3 4 5 6 7 8 9** ~~Pe Ga ee ET~~[“$EeEUE] **Packaging options and max. cable length see on the part number generator - www.neutrik.com 0** _**-0 . . . Only airspool packaging available**_
## **Packaging options and max. cable length see on the part number generator - www.neutrik.com**
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**33**_
## **optical** _**CON®**_ **MTP** _**®**_ **24 LITE Cable Connector Assembly**
**NKO24M-L***
- _**24-channel MTP[®] based fiber optic connection system**_
- _**Waterproof acc . to IP65 safety standard in mated condition**_
- _**Recommended for multi-signal transmission**_
- _**Push-pull locking mechanism**_
- _**Custom color coding**_
- _**Rugged housing**_
- _**Rubber protection cap**_
- _**Compatible with standard opticalCON ADVANCED NO24FDW-A chassis**_
**==> picture [503 x 184] intentionally omitted <==**
**----- Start of picture text -----**<br>
(Oc hs {e-<br>wy, A<br>* . . . MTP ® is a trademark of US Conec (www .usconec .com)<br>On SETTING —<br>STANDARDS<br>Ø27.0 [1.06"] Ø25.5 [1.0"]<br>**----- End of picture text -----**<br>
_**34**_
**==> picture [12 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTP ®<br>**----- End of picture text -----**<br>
## **Technical Data**
**==> picture [494 x 320] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|Technical Data Optical Cable Connector|Technical Data Cables|
|Optical connector|MTP|®|ELITE|
|female|
|Fiber|Multimode, Singlemode APC||
|Insertion loss|< 0 .9 dB / connection||
|min . Return loss|MM PC|[>]|25 dB||Max . numbers of fibers|24|24|
|SM APC|[> ]|60 dB||Mode - Multimode PC||-|
|- Single mode PC / APC|-||
|MECHANICAL|Fiber|- 50 / 125-OM3||-|
|- 9 / 125-G657A2|-||
|Insertion / withdrawal force|< 45 N||Bend optimized fiber|||
|Lifetime (mating cycles)|> 1’500||Laser optimized fiber||-|
|Cable retention force|Fiber only > 500 N||Cable retention|
|Hybrid > 500 N||- Aramid yarn|||
|SMPTE > 500 N||- Crimp type|-|-|
|Overall diameter|(mm)|3 .5|3 .5|
|MATERIAL|Jacket - PUR black matte|||
|Optical connector|
|Shell|PBT 30% GR||-|-|
|- LC-Duplex|
|Insert / Insulation|PC, PEI||- LC based|||
|Strain relief|Brass, Ni plated||
|Min . bending radius|(cm)|3 .5|3 .5|
|Bushing|PA6||
|Weight|(kg / km)|12 .0|12 .0|
|Boot|EPDM, rubber boot||Attenuation|(dB / km)|@@1300 nm 850 nm|[≤][≤]|3 .0 1 .0|@@1310 nm 1550 nm|[≤][≤]|3 .0 1 .0|
|ENVIRONMENTAL|Bandwidth|(MHz-km)|@@|850 nm 1300 nm|≥≥|1500500|@@|850 nm 1300 nm|≥≥|1500500|
|Refraction index|@850 nm - 1 .481|@1310 nm - 1 .481|
|@1550 nm - 1 .476|@1550 nm - 1 .476|
|Operating temp .|-40°C to +75°C||
|Flammability|UL94 HB||
|Protection class|in mated condition IP65||
**----- End of picture text -----**<br>
**Accessories for Cable Connector**
**SCNKO-L NOR-*** _**SCNKO-L Rubber dirt protection for opticalCON LITE cable connector (spare part) NOR-* Color coding ring for cable connector chassis *: 0- black, 1- brown, 2- red, 3-orange, 4- yellow, 5- green, 6- blue, 7- violet, 8- grey, 9- white**_ **0 1 2 3 4 5 6 7 8 9** ee ee en ns ee en ee **Packaging options and max. cable length see on the part number generator - www.neutrik.com 0** _**-0 . . . Only airspool packaging available**_
## **Packaging options and max. cable length see on the part number generator - www.neutrik.com**
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**35**_
##
_**36**_
**Features & Benefits**
## **Small form factor** ~~=~~ **Automatic sealing shutter** es **Simple integration**
## SS ES ES **optical** _**CON**_ **DUO optical** _**CON**_ **QUAD optical** _**CON**_ **MTP** _**®**_ **12 optical** _**CON**_ **MTP** _**®**_ **24**
**==> picture [304 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
NO2-4FDW-A NO4FDW-A NO12FDW-A<br>**----- End of picture text -----**<br>
_**Standard LC connector**_
_**Standard LC connector**_
_**MTP[®] ELITE MALE connnector**_
**==> picture [113 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
NO24FDW-A<br>MTP [®] ELITE MALE connnector<br>**----- End of picture text -----**<br>
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**37**_
## **optical** _**CON®**_ **DUO ADVANCED Chassis Connector**
**NO2-4FDW-A with SCDP-0**
- _**Ruggedized and dirt-protected 2-channel fiber optic connection system**_
- _**Shutter with silicon gasket protects optical connection from dust and dirt**_
- _**Suggested OEM equipment connectors due to LC front compatibility**_
- _**Accommodates standard LC connectors on the rear for simple installation**_
- _**IP65 ingress protection in mated condition with SCDP-***_
- _**Connection on the front side either by rugged opticalCON or standard LC connector**_
**Example: opticalCON DUO Chassis with transceiver adapter and SFP tranceiver**
**==> picture [48 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
NAO2*-SFP-LC<br>**----- End of picture text -----**<br>
_**38**_
## **Technical Data**
## **Technical Data Optical Chassis Connector**
|**_Optical connector_**|**_Optical connector_**||**_LC-Duplex_**|
|---|---|---|---|
||||**_Feedthrough_**|
|**_Fiber_**<br>|**_Multimode, Singlemode PC / APC_**|||
|**_Insertion loss_**<br>|**_< 0 .45 dB / connection_**|||
|**_min . Return loss_**|**_MM PC> 25 dB_**|**_25 dB_**||
|**_SM PC > 50 dB_**|**_SM PC > 50 dB_**|||
||**_SM APC> 60 dB_**|||
|**MECHANICAL**||||
|**_Insertion / withdrawal force_**<br>||**_< 45 N_**||
|**_Lifetime (mating cycles)_**<br>**_> 5’000_**||**_> 5’000_**||
|**ELECTRICAL**||||
|**_Number of electrical contacts_**<br>||**_4 (5)2_**||
|**_Rated current_**||**_6 A_**||
|||**_10 A(contact 1+4)_**||
|**_Contact resistance_**|**_Contact resistance_**<br>|**_< 7 m_**Ω||
|**_Insulation resistance_**<br>**_- initial: > 10 G_**||**_- initial: > 10 G_**Ω||
|**_- after damp heat test: > 1 G_**|**_- after damp heat test: > 1 G_**|**_- after damp heat test: > 1 G_**Ω||
|**_Dielectric strength_**|**_Dielectric strength_**<br>|**_1500 V dc_**||
|**_Rated voltage _**||**_50 V ac_**|**_1_**|
|**MATERIAL**||||
|**_Shell_**|**_Zinc diecast (ZnAl4Cu1), black chrome plating_**|||
|**_Insert / Insulation_**|**_Insert / InsulationPolyamid PA 6, PBT 30% GR_**|||
|**_Insert colour_**|**_MM: black, SM PC: blue; SM APC: green_**|||
|**_Contacts_**|**_female: Brass (CuZn39Pb3)_**|||
|**_Contact surface_**|**_Gold(gal 0 .2 µm Au over 2 µm Ni)_**|**_(gal 0 .2 µm Au over 2 µm Ni)_**||
|**_Split sleeve_**|**_Ceramics_**|||
|**ENVIRONMENTAL**||||
|**_Operating temp ._**|**_-40°C to +75°C_**|**_-40°C to +75°C_**||
|**_Flamability_**|**_UL94 HB_**|||
|**_Solderability_**|**_complies with IEC 68-2-20_**|||
|**_Protection class_**|**_in combination with SCDP-* in mated condition IP65_**|||
_**1 . . . Not compatible to SMPTE 304M standard . Suitable for indoor (studio) camera links considering specific conditions acc . to IEC 60664-1 like pollution degree 1, overvoltage category 1 and rated voltage . For detailed information ask for the White Paper “opticalCON @ SMPTE Indoor Applications” . 2 . . . Shell ground contacts**_
|**optical****_CON_ DUO Chassis**|**DUO Chassis**||||||
|---|---|---|---|---|---|---|
||**_Type_**|**_Plating_**|**_Fiber_**|**_Solder contacts_**|**_Shell ground contact_**|**_Wiring_**|
|**_NO2-4FDW-A_**|**_Chassis_**|**_Black Chrome_**|**_2_**|**_4_**|**_-_**|**_-_**|
|**_NO2-4FDW-1-A_**|**_Chassis_**|**_Black Chrome_**|**_2_**|**_4_**|**_1_**|**_-_**|
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**39**_
## **optical** _**CON®**_ **QUAD ADVANCED Chassis Connector**
## **NO4FDW-A with SCDP-0**
- _**Ruggedized and dirt-protected 4-channel fiber optic connection system**_
-
-
-
-
- _**For point-to-point multichannel routing**_
- _**Laser protective metal shutter seals dust proof with two-component rubber gasket**_
- _**IP65 ingress protection in mated condition with SCDP-***_
- _**Accommodates standard LC connectors on the rear for simple installation**_
**==> picture [17 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
QUAD<br>4<br>**----- End of picture text -----**<br>
_**40**_
## **Technical Data**
|**Technical Data Optical Chassis Connector**|**Technical Data Optical Chassis Connector**||
|---|---|---|
|**_Optical connector_**|**_Optical connector_**|**_PC_**|
|||**_Feedthrough_**|
|**_Fiber_**<br>|**_Multimode, Singlemode PC / APC_**||
|**_Insertion loss_**<br>|**_< 0 .45 dB / connection_**||
|**_min . Return loss_**|**_MM PC> 25 dB_**||
|**_SM PC > 50 dB_**|**_SM PC > 50 dB_**||
||**_SM APC> 60 dB_**||
|**MECHANICAL**|||
|**_Insertion / withdrawal force_**<br> **_< 45 N_**|||
|**_Lifetime (mating cycles)_**<br>**_> 5’000_**|||
|**MATERIAL**|||
|**_Shell_**<br>|**_Zinc diecast (ZnAl4Cu1), black chrome plating_**||
|**_Insert / Insulation_**|**_Insert / InsulationPolyamid PA 6, PBT 30% GR_**||
|**_Insert colour_**<br>|**_MM: black, SM PC: blue; SM APC: green_**||
|**_Split sleeve_**<br>|**_Ceramics_**||
|**ENVIRONMENTAL**|||
|**_Operating temp ._**|**_-40°C to +75°C_**||
|**_Flamability_**|**_UL94 HB_**||
|**_Protection class_**|**_in combination with SCDP-* in mated condition IP65_**||
|**optical****_CON_ QUAD Chassis**|**QUAD Chassis**||||||
|---|---|---|---|---|---|---|
||**_Type_**|**_Plating_**|**_Fiber_**|**_Solder contacts_**|**_Shell ground contact_**|**_Wiring_**|
|**_NO4FDW-A_**|**_Chassis_**|**_Black Chrome_**|**_4_**|**_-_**|**_-_**|**_-_**|
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**41**_
## **optical** _**CON®**_ **MTP** _**®**_ **12 ADVANCED Chassis Connector**
## **NO12FDW-A with SCDP-0**
- _**Ruggedized and dirt-protected 12-channel fiber optic connection system**_
-
-
- _**For point-to-point multichannel routing**_
- _**Laser protective metal shutter seals dust proof with two-component rubber gasket**_
- _**IP65 ingress protection in mated condition with SCDP-***_
- _**Accommodates standard MTP ® ELITE MALE connectors on the rear for simple installation***_
**==> picture [37 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTP®<br>12<br>X TT y<br>**----- End of picture text -----**<br>
_*** . . . MTP ® is a trademark of US Conec (www .usconec .com)**_
_**42**_
**==> picture [12 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTP ®<br>**----- End of picture text -----**<br>
## **Technical Data**
## **Technical Data Optical Chassis Connector**
|**_Optical connector_**|**_Optical connector_**|**_MTP_**|**®****_ELITE female_**|
|---|---|---|---|
|||**_Feedthrough_**||
|**_Fiber_**<br>|**_Multimode, Singlemode APC_**|||
|**_Insertion loss_**<br>|**_< 0 .9 dB / connection_**|||
|**_min . Return loss_**|**_MM PC> 25 dB_**|||
||**_SM APC> 60 dB_**|||
|**MECHANICAL**||||
|**_Insertion / withdrawal force_**<br> **_< 45 N_**||||
|**_Lifetime (mating cycles)_**<br>**_> 2’500_**||||
|**MATERIAL**||||
|**_Shell_**|**_Zinc diecast (ZnAl4Cu1), black chrome plating_**|||
|**_Insert / Insulation_**|**_Insert / InsulationPolyamid PA 6, PBT 30% GR_**|||
|**_Insert colour_**|**_MM: black, SM PC: blue; SM APC: green_**|||
|**ENVIRONMENTAL**||||
|**_Operating temp ._**|**_-40°C to +75°C_**|||
|**_Flamability_**|**_UL94 HB_**|||
|**_Protection class_**|**_in combination with SCDP-* in mated condition IP65_**|||
## **optical** _**CON**_ **MTP** _**[®]**_ **12 Chassis**
||**_Type_**|**_Plating_**|**_Fiber_**|**_Solder contacts_**|**_Shell ground contact_**|**_Wiring_**|
|---|---|---|---|---|---|---|
|**_NO12FDW-A_**|**_Chassis_**|**_Black Chrome_**|**_12_**|**_-_**|**_-_**|**_-_**|
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**43**_
## **optical** _**CON®**_ **MTP** _**®**_ **24 ADVANCED**
## **Chassis Connector**
## **NO24FDW-A with SCDP-0**
- _**Ruggedized and dirt-protected 24-channel fiber optic connection system**_
-
-
- _**For point-to-point multichannel routing**_
- _**Laser protective metal shutter seals dust proof with two-component rubber gasket**_
- _**IP65 ingress protection in mated condition with SCDP-***_
- _**Accommodates standard MTP ® ELITE MALE connectors on the rear for simple installation***_
**==> picture [37 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTP®<br>24<br>X TT y<br>**----- End of picture text -----**<br>
_*** . . . MTP ® is a trademark of US Conec (www .usconec .com)**_
_**44**_
**==> picture [12 x 4] intentionally omitted <==**
**----- Start of picture text -----**<br>
MTP ®<br>**----- End of picture text -----**<br>
## **Technical Data**
## **Technical Data Optical Chassis Connector**
|**_Optical connector_**|**_Optical connector_**||**_MTP_**|**®****_ELITE female_**|
|---|---|---|---|---|
||||**_Feedthrough_**||
|**_Fiber_**<br>|**_Multimode, Singlemode APC_**||||
|**_Insertion loss_**<br>|**_< 0 .9 dB / connection_**||||
|**_min . Return loss_**|**_MM PC> 25 dB_**|**_25 dB_**|||
||**_SM APC> 60 dB_**||||
|**MECHANICAL**|||||
|**_Insertion / withdrawal force_**<br>||**_< 45 N_**|||
|**_Lifetime (mating cycles)_**<br>**_> 2’500_**||**_> 2’500_**|||
|**MATERIAL**|||
|---|---|---|
|**_Shell_**|**_Zinc diecast (ZnAl4Cu1), black chrome plating_**||
|**_Insert / Insulation_**|**_Insert / InsulationPolyamid PA 6, PBT 30% GR_**||
|**_Insert colour_**|**_MM: black, SM PC: blue; SM APC: green_**||
|**ENVIRONMENTAL**|||
|**_Operating temp ._**|**_-40°C to +75°C_**||
|**_Flamability_**|**_UL94 HB_**||
|**_Protection class_**|**_in combination with SCDP-* in mated condition IP65_**||
|**optical****_CON_ MTP**|**MTP** **_®_24 Chassis**||||||
|---|---|---|---|---|---|---|
||**_Type_**|**_Plating_**|**_Fiber_**|**_Solder contacts_**|**_Shell ground contact_**|**_Wiring_**|
|**_NO24FDW-A_**|**_Chassis_**|**_Black Chrome_**|**_24_**|**_-_**|**_-_**|**_-_**|
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**45**_
**Accessories for Chassis & Couplers**
## **Ordering Information**
## ~~|~~ **Accessories for Chassis**
**SCNO-FDW-A SCD-NC SCDP-* SCCD-W** _**SCNO-FDW-A Rugged sealing cover for opticalCON chassis connectors SCD-NC Rubber sealing cover for opticalCON chassis connectors SCDP-* D-Size sealing gaskets for chassis, color coding according to ANSI/TIA-568-3-D Standard SCCD-W Spring-loaded cover to seals D-size chassis connectors, IP65 rated *: 0- black, 1- brown, 2- red, 3-orange, 4- yellow, 5- green, 6- blue, 7- violet, 8- grey, 9- white**_ **0 1 2 3 4 5 6 7 8 9** ee ee ee _**1) :find part numbers on www .neutrik .com**_
## **COUPLER**
## _**Weatherproof opticalCON coupler (adapter) for cable extensions .**_
**NAO2S-H1W-A**
**NAO4MW-A**
**NAO12SAW-A**
**NAO24MW-A**
||**_Type_**|**_Colour_**|**_Plating_**|**_Fiber_**|**_Solder contacts_**|**_Shell ground contact_**|**_Shell ground contact_**<br>**_Wiring_**|
|---|---|---|---|---|---|---|---|
|**_NAO2M-H1W-A_**|**_Coupler_**|**_black_**|**_black_**|**_2 x LC-Duplex Multimode PC_**|**_4 x 0 .75 mm2 _**||**_ISO/IEC 11801_**|
|**_NAO2S-H1W-A_**|**_Coupler_**|**_blue_**|**_black_**|**_2 x LC-Duplex Singlemode PC_**|**_4 x 0 .75 mm2 _**||**_ISO/IEC 11801_**|
|**_NAO2SA-H1W-A_**|**_Coupler_**|**_green_**|**_black_**|**_2 x LC-Duplex Singlemode APC_**|**_4 x 0 .75 mm2 _**||**_ISO/IEC 11801_**|
|**_NAO2SA-H1W-AX_**|**_Coupler_**|**_green_**|**_black_**|**_2 x LC-Duplex Singlemode APC_**|**_4 x 0 .75 mm2 _**||**_crossed_**|
|**_NAO4MW-A_**|**_Coupler_**|**_black_**|**_black_**|**_4 x Multimode PC_**|**_-_**|**_-_**|**_ISO/IEC 11801_**|
|**_NAO4MW-AX_**|**_Coupler_**|**_black_**|**_black_**|**_4 x Multimode PC_**|**_-_**|**_-_**|**_crossed_**|
|**_NAO4SW-A_**|**_Coupler_**|**_blue_**|**_black_**|**_4 x Singlemode PC_**|**_-_**|**_-_**|**_ISO/IEC 11801_**|
|**_NAO4SW-AX_**|**_Coupler_**|**_blue_**|**_black_**|**_4 x Singlemode PC_**|**_-_**|**_-_**|**_crossed_**|
|**_NAO4SAW-A_**|**_Coupler_**|**_green_**|**_black_**|**_4 x Singlemode APC_**|**_-_**|**_-_**|**_ISO/IEC 11801_**|
|**_NAO4SAW-AX_**|**_Coupler_**|**_green_**|**_black_**|**_4 x Singlemode APC_**|**_-_**|**_-_**|**_crossed_**|
|**_NAO4SW-A-X_**|**_Coupler_**|**_red_**|**_black_**|**_4 x Singlemode PC_**|**_-_**|**_-_**|**_ISO/IEC 11801_**|
|**_NAO12MW-A_**|**_Coupler_**|**_black_**|**_black_**|**_12 x Multimode PC_**|**_-_**|**_-_**|**_Type A_**|
|**_NAO12SAW-A_**|**_Coupler_**|**_green_**|**_black_**|**_12 x Singlemode APC_**|**_-_**|**_-_**|**_Type A_**|
|**_NAO24MW-A_**|**_Coupler_**|**_black_**|**_black_**|**_24 x Multimode PC_**|**_-_**|**_-_**|**_Type A_**|
|**_NAO24SAW-A_**|**_Coupler_**|**_green_**|**_black_**|**_24 x Singlemode APC_**|**_-_**|**_-_**|**_Type A_**|
. =
_**46**_
**Transceiver Adapter**
## ~~ee~~ **TRANSCEIVER ADAPTER**
_**The opticalCON Transceiver Adapter connects an opticalCON chassis (NO2-4FDW*) and a LC SFP transceiver . NAO2*-SFP-LC consists of two LC-SFP adapters, 2 flat gaskets (1 mm and 2 mm) and one NO2-4FDW-A without copper contacts .**_
**MM Transceiver Adapter SM Tranceiver Adapter SM APC Tranceiver Adapter grey blue green**
- _**Eases design integration of the opticalCON chassis connectors (NO2-4FDW*) in combination with SFP transceivers**_
- _**Compatible with all LC SFP transceivers**_
- _**Automatic sealing shutter of the opticalCON avoids transceiver soiling**_
- _**Enables use of rugged opticalCON or conventional LC connectors**_
- _**Avoids vandalism, opticalCON “protects” the transceiver**_
_**NAO2M-SFP-LC grey MM Transceiver Adapter + opticalCON chassis (NO2-4FDW-A) without copper contacts NAO2S-SFP-LC blue SM Transceiver Adapter + opticalCON chassis (NO2-4FDW-A) without copper contacts NAO2SA-SFP-LC green SM APC Transceiver Adapter + opticalCON chassis (NO2-4FDW-A) without copper contacts**_
## ~~ee~~ **NAOBO - Breakout ADAPTER**
_**NAOBO is a flexible chassis mounting and adaption solution with cable strain relief to meet any kind of standard fiber connector (e .g . LC, SC, ST) . It can be fixed to a rack with a cable tie . The breakout adapter can be mounted straight or angled .**_
**==> picture [39 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
Application<br>example<br>**----- End of picture text -----**<br>
**==> picture [44 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
NAOBO (KIT)<br>**----- End of picture text -----**<br>
- _**Flexible chassis mounting solution**_
- _**Adaption solution to meetexisting non-opticalCON fiber installation**_
- _**NAOBO can be equipped with any D-size chassis connector**_
_**NAOBO Breakout Adapter Kit consisting of: 1 NAOBO plastic housing, 1 counter nut, 1 90° rear shell, 1 PG-gland, 1 cable tie and 2 screws**_
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**47**_
## **Breakout Solutions**
## **Breakout Box**
**NO12SABB6D-A**
**==> picture [69 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
NO4SBB4D-PM-A<br>(with powerMONITOR)<br>**----- End of picture text -----**<br>
## **opticalCON Breakout Box**
- _**Breakout boxes are used to split multichannel connections as the opticalCON QUAD and MTP[®] to either dual or single channels**_
-
- _**Dust and waterproof according to IP67 in mated condition**_
## **opticalCON Breakout Box with powerMONITOR**
_**The breakout boxes are used to split a 4-channel point-to-point opticalCON QUAD connection . In mated condition the boxes are dust and water resistant according protection class IP54 . The breakout boxes equiped with the opticalCON powerMONITOR offer attenuation measuring for all 4 channels .**_
_**The opticalCON powerMONITOR is a cost-saving, purpose-built measurement (monitoring) device for professional fiber optic broadcast, audio and video applications .**_
_**With simultaneous monitoring of attenuation for up to 4 transmission channels, powerMONITOR provides an immediate, “on air” view into fiber optic signal strength . Visual and audible alarms can be set individually for each fiber channel, based on each channel’s power budget . powerMONITOR provides clear status information, delivers early warnings for potential problems, and assists with maintenance scheduling .**_
-
-
-
-
- _**On-air monitoring of fiber optic transmission quality**_
- _**Simultaneous power measurement (+0 .0/-0 .1 dB measurement accuracy) of up to 4 channels**_
- _**Programmable-threshold alarms**_
- _**Rackmount and mobile units**_
- _**Operates on rechargeable battery power or on mains power with fail-safe battery backup in case of unexpected mains power interruption**_
-
- _**Low loss (0 .5 dB maximum split loss)**_
- _**Wavelength selectable: multimode 850 nm or 1300 nm, single mode 1310 nm, 1550 nm or WDM (wave division multiplexing)**_
_**48**_
~~Ld~~ **Breakout Box** _**NO4SBB2D-A[1)] 1 x NO4FDW-A to 2 x NO2-4FDW-A, Singlemode PC NO4SABB2D-A[1)] 1 x NO4FDW-A to 2 x NO2-4FDW-A, Singlemode APC NO4MBB2D-A[1)] 1 x NO4FDW-A to 2 x NO2-4FDW-A, Multimode PC**_ ~~—~~ _**NO4SBB4D-A 1 x NO4FDW-A to 4 x NO2-4FDW-A, Singlemode PC NO4SABB4D-A 1 x NO4FDW-A to 4 x NO2-4FDW-A, Singlemode APC NO4MBB4D-A 1 x NO4FDW-A to 4 x NO2-4FDW-A, Multimode PC NO12SAABB6D-A 1 x NO12FDW-A to 6 x NO2-4FDW-A, Singlemode APC to APC NO12SABB6D-A 1 x NO12FDW-A to 6 x NO2-4FDW-A, Singlemode APC to PC**_ **A B A B A B A B A B A B** _**NO12MBB6D-A 1 x NO12FDW-A to 6 x NO2-4FDW-A, Multimode PC NO12SAABB3Q-A 1 x NO12FDW-A to 3 x NO4FDW-A, Singlemode APC to APC NO12SABB3Q-A 1 x NO12FDW-A to 3 x NO4FDW-A, Singlemode APC to PC**_ **A a b B A a b B A a b B** _**NO12MBB3Q-A 1 x NO12FDW-A to 3 x NO4FDW-A, Multimode PC NO24SABB2M12-A 1 x NO24FDW-A to 2 x NO12FDW-A, Singlemode APC NO24MBB2M12-A 1 x NO24FDW-A to 2 x NO12FDW-A, Multimode PC**_
## ~~Ld~~ **Breakout Box with powerMONITOR**
_**NO*BB1*-PM-A[1)] 1)breakout box equipped with opticalCON powerMONITOR . . . add attribute X for crossed fiber wiring**_ ~~i~~
## ~~CT~~ **Power Supply for powerMONITOR**
**==> picture [370 x 191] intentionally omitted <==**
**----- Start of picture text -----**<br>
NOPS-1RU-PM NOPS-3RU-PM NOPS-E-PM<br>opticalCON powerMONITOR 5W Power Supply, powers up to 2 power monitors, Intern . AC plugs included<br>opticalCON powerMONITOR 15W Power Supply, 1 + 3RU use, powers up to 9 power monitors, IEC power socket<br>opticalCON powerMONITOR, power supply extension cable to dasisy-chain power<br>183 [7.2]<br>CH13-24<br>CH1-24 opticalCON NO24-SABB2M12-ATSINGLEMODE 9/125-G657A APCLIECHTENSTEIN CH1-12<br> — |i)<br>26 [1.02]<br>62 [2.45]<br>**----- End of picture text -----**<br>
_**NOPS-1RU-PM opticalCON powerMONITOR 5W Power Supply, powers up to 2 power monitors, Intern . AC plugs included NOPS-3RU-PM opticalCON powerMONITOR 15W Power Supply, 1 + 3RU use, powers up to 9 power monitors, IEC power socket NOPS-E-PM opticalCON powerMONITOR, power supply extension cable to dasisy-chain power**_
**==> picture [19 x 3] intentionally omitted <==**
**----- Start of picture text -----**<br>
NOX.BBXX-A<br>**----- End of picture text -----**<br>
**==> picture [47 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
Breakout Box<br>**----- End of picture text -----**<br>
**NO24SABB2M12-A**
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**49**_
_**®**_
## **optical** _**CON®**_ **powerMONITOR**
## **On air monitoring of fiber optic transmission quality**
**==> picture [60 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
NO4S-4F-2R-PM-A<br>**----- End of picture text -----**<br>
_**The opticalCON powerMONITOR is a cost-saving, purposebuilt measurement (monitoring) device for professional fiber optic broadcast, audio and video applications . With simultaneous monitoring of attenuation for up to 4 transmission channels, powerMONITOR provides an immedi-**_
_**ate, “on air” view into fiber optic signal strength . Visual and audible alarms can be set individually for each fiber channel, based on each channel’s power budget . powerMONITOR provides clear status information, delivers early warnings for potential problems, and assists with maintenance scheduling .**_
- _**On-air monitoring of fiber optic transmission quality**_
- _**Simultaneous power measurement ([+] 0 .0/[-] 0 .1 dB measurement accuracy) of up to 4 channels**_
- _**Programmable threshold alarms**_
- _**Rack mount and mobile units**_
- _**Operates on rechargeable battery power or on mains power with fail-safe battery backup in case of unexpected mains power interruption**_
- _**Low loss (0 .5 dB maximum split loss)**_
- _**Wavelength selectable: multimode 850 nm or 1300 nm, single mode 1310 nm, 1550 nm or WDM (wave division multiplexing)**_
**Example**
**Front view: e.g. 4F (opticalCON QUAD)**
**Rear view: e.g. 2R (opticalCON DUO)**
_**50**_
## **powerMONITOR**
||**_Channel_**|**_Mode_**|**_Chassis Front_**|**_Chassis Rear_**|
|---|---|---|---|---|
|**_NO2S-2F-2R-PM-A_**|**_2_**|**_S_**|**_DUO_**|**_DUO_**|
|**_NO2SA-2F-2R-PM-A_**|**_2_**|**_SA_**|**_DUO_**|**_DUO_**|
|**_NO4SA-2F-2R-PM-A_**|**_4_**|**_SA_**|**_QUAD_**|**_DUO_**|
|**_NO4SA-4F-4R-PM-A_**|**_4_**|**_SA_**|**_QUAD_**|**_QUAD_**|
|**_NO4M-4F-4R-PM-A_**|**_4_**|**_M_**|**_QUAD_**|**_QUAD_**|
_**1) . . . add attribute X for crossed fiber wiring**_
## ~~ee~~ **Power Supply for powerMONITOR**
**NOPS-1RU-PM NOPS-3RU-PM**
**NOPS-E-PM**
_**NOPS-1RU-PM opticalCON powerMONITOR 5W Power Supply, powers up to 2 power monitors, Intern . AC plugs included NOPS-3RU-PM opticalCON powerMONITOR 15W Power Supply, 1 + 3RU use, powers up to 9 power monitors, IEC power socket NOPS-E-PM opticalCON powerMONITOR, power supply extension cable to dasisy-chain power**_
## **1 RU & 3 RU 19” Rack units with powerMONITOR**
**NO4S-4F-2R-PM-A (up to two power** _**MONITOR’s**_ **)**
**up to 9 power** _**MONITOR’s**_
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**51**_
## **Panel Solutions**
## **19” D-Shape Z-Panels & Plates**
**==> picture [30 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
NZPF1RU<br>**----- End of picture text -----**<br>
**==> picture [30 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
NZPF3RU<br>**----- End of picture text -----**<br>
- _**Space saving design, ideal for cramped rack applications such as OB truck I/O panels**_
- _**Frame plate can be loaded with opticalCON DUO or QUAD and E2000 or ST or SC**_
- _**Frames can be equipped with frame plates (D-shape) or blind plates**_
- _**Best cable bend protection**_
- _**1 RU or 3 RU frame**_
## **Panel frame 1RU**
**==> picture [73 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Application Example:<br>**----- End of picture text -----**<br>
**==> picture [191 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
NO2-4FDW-A<br>2 x NOSPS-50LC-50LC<br>NO2-4FDW-A<br>NZPFD-2<br>**----- End of picture text -----**<br>
## **Panel frame 3RU**
_**52**_
**==> picture [511 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cd Z-Panels<br>**----- End of picture text -----**<br>
|**Panel frame 1RU: NZPF1RU**<br>**Panel frame 3RU: NZPF3RU**||
|---|---|
|**5**<br>**5**<br>**4**<br>**6**<br>**7**<br>**8**<br>**9**||
|**2**<br>**1**||
|**e.g. NO4FDW-A**<br>**e.g. opticalCON Chassis NO4FDW-A**||
|**with SCDP-4**<br>**with sealing gasket SCDP-5**<br>**e.g. NO2-4FDW-A**||
|**5**<br>**6**<br>**7**<br>**8**<br>**9**<br>**10**<br>~~@~~<br>~~@~~<br>~~@~~<br>~~@~~<br>~~@~~<br>~~@~~||
|**Splitter: NOSPS-50LC-50LC**<br>**Angled rack panel: NZP1RU-8**||
|**50 %**||
|**100 %**<br>**50 %**<br>**3**<br>**11**||
|**Panel Frame**<br>**_NZPF1RU_**<br>**_Panel frame 1RU for opticalCON panel frames_**<br>**_NZPF3RU_**<br>**_Panel frame 3RU for opticalCON panel frames_**<br>**_NZP1RU-8_**<br>**_Panel 1RU, 30° forward-turned and offers 8 x D-shape cutouts with M3 threaded fastening holes_**<br>**_NZP1RU-12_**<br>**_Panel 1RU, 30° forward-turned and offers 12 x D-shape cutouts with M3threaded fastening holes_**<br>**Panel Plate**<br>**_NZPFBP_**<br>**_Panel frame blind plate_**<br>**_NZPFD_**<br>**_Panel frame plate for opticalCON chassis connector_**<br>**_NZPFD-2_**<br>**_Panel frame plate 2 x D-shape cutouts (works only on NZPF3RU Panel)_**<br>**_NZPFD-4E_**<br>**_Panel frame plate 1 x D-shape cutout, 2 E2000 compact chassis cutouts_**<br>**_NZPFD-4SC_**<br>**_Panel frame plate 1 x D-shape cutout, 2 SC compact chassis cutouts_**<br>**_NZPFD-4ST_**<br>**_Panel frame plate 1 x D-shape cutout, 4 ST chassis cutouts_**<br>**_NZPFD-4SC-S_**<br>**_Panel frame plate 1 x D-shape cutout, 4 SC simplex cutouts_**<br>**Splitter**<br>**_NOSPM-LC50-LC50_**<br>**_Multimode 1 x 2 splitter LC*_**<br>**_NOSPS-LC50-LC50_**<br>**_Singlemode PC 1 x 2splitter LC*_**<br>**1**<br>**2**<br>**3**<br>**3**<br>**4**<br>**5**<br>**6**<br>**7**<br>**8**<br>**9**<br>**11**<br>**11**<br>**10**<br>4<br>@<br>@<br>@<br>~~ee~~<br>e@<br>e<br>e@<br>@<br>@<br>e<br>@||
_*** . . . other connectors (SC, ST, E200) on request**_
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**53**_
## **Ordering Information**
## **Fiber Optic Measurement & Cleaning Kit**
**FOCD-CF**
**==> picture [53 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
CAS-FOCD-ADV<br>**----- End of picture text -----**<br>
**FOMD-FM-MM**
**FOCD-DC125/250 FOCD-DCM**
**CAS-FOMD FOMD-TC-SM1550**
**FOMD-FM-SM**
_**CAS-FOCD-ADV Fiber Optic Cleaning Devices - CASE contains hand microscope, opticalCON measurement adapter, cleaning set FOCD-CF[1)] Cleaning Fluid FOCD-DC125[1)] DRY Cleaner 1 .25 mm FOCD-DC250[1)] DRY Cleaner 2 .5 mm FOCD-DCM DRY Cleaner MTP[®] , cleaning brush for guidance holes FOCD-DW[1)] Lint-free dry wipes for fiber cleaning**_
_**CAS-FOMD-ADV Fiber Optic Measurement Devices - CASE contains power source frame, 1 .25 mm adapter and multimode attenuator FOMD-TC-MM850[2)] Transceiver 850 nm multimode FOMD-TC-SM1310[2)] Transceiver 1310 nm singlemode FOMD-TC-SM1550[2)] Transceiver 1550 nm singlemode FOMD-FM-MM[2)] Fiber meter multimode FOMD-FM-SM[2)] Fiber meter singlemode**_
_**1) . . . refill consumable, in CAS-FOCD included 2) . . . combine with CAS-FOMD**_
——
_**54**_
## **Fiber Optic Cleaning Accessories**
**FOCD-STD**
**FOCD-STQ**
**FOCD-STM**
- _**Enhanced inspection and cleaning procedure**_
- _**Lockable with opticalCON cable connector**_
- _**Compatible with conventional cleaning and inspection equipment**_
|**_FOCD-STD_**|**_Service tool for opticalCON DUO_**|
|---|---|
|**_FOCD-STQ_**|**_Service tool for opticalCON QUAD_**|
|**_FOCD-STM_**|**_Service tool for opticalCON MTP®_**|
## **optical** _**CON**_ **Connector Field Assembly**
**optical** _**CON**_ **connector Field assembly**
- _**Neutrik opticalCON field assembly kit**_
- _**Based on Corning UniCam pre-polished LC connectors**_
- _**No additional tooling required**_
- _**Requires completion of a certified Neutrik opticalCON field assembly training**_
-
- _**Find more details on www .neutrik .com**_
**optical** _**CON® - fiber optic connection system**_
**www.neutrik.com**
_**55**_
Updated at February 9, 2023
Neutrik, a flagship brand of the Neutrik Group, is a globally recognized leader in the design and manufacture of high-performance connector systems for the professional entertainment and industrial sectors. With decades of engineering excellence and ISO-certified manufacturing, the company has established a reputation for producing highly durable and innovative connectivity solutions trusted worldwide. While renowned for its industry-standard audio and video connectors, Neutrik's expertise extends deeply into advanced data transmission and ruggedized cabling. Our selection of Neutrik components focuses on these premium cable assemblies, engineered to deliver flawless digital and optical signal integrity in demanding professional environments. The portfolio features robust USB and Lightning cable assemblies designed to withstand the rigors of continuous use while ensuring secure, high-speed data transfer. Additionally, Neutrik's precision-engineered fiber optic lead assemblies provide superior optical performance and environmental protection, making them the ideal choice for mission-critical networking and broadcast infrastructure where uncompromising reliability is required.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →