LEN120-48
AC/DC DIN Rail Power Supply (PSU), ITE, Industrial & Household, 1 Output, 120 W, 48 VDC, 2.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL POWER SOLUTIONS
- Product type:
- Available until stocks are exhausted
- SVHC: To Be Advised
- Product Range: LEN120 Series
- No. of Outputs: 1 Output
- Output Power Max: 120W
- Current, Output 4: -
- Input Voltage VAC: 90V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 2.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Household
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 38.92 € |
| Current stock | 10+ |
| Lead time | 30 days |
## LEN120 Series 120 W AC-DC DIN Rail Switching Power Supply LEN120 Series is Bel Power Solutions AC-DC converter series featuring a cost-effective, energy efficient green power supply solution for standard DIN-rail mounting. The products offer a high level of stability and immunity to noise for industrial control equipment, machinery, and other industrial equipment in a variety of harsh environments. These light weight AC-DC converters have an extremely compact design and the standard rail (35 mm) installation for space saving. With good EMC performance, compliant with international UL 61010-1, UL 508, EN 62368-1 standards for EMC and safety. ## **FEATURES** - Input voltage 90 - 264 VAC (universal) or 127 - 370 VDC • Output voltage 12 V, 24 V, 48 V (adjustable) - Operating ambient temperature range -20°C to +60°C - High I/O isolation test voltage up to 4000 VAC - Low ripple & noise - Output short circuit, over-current, over-voltage, over-temperature protection - DIN rail TS-35/7.5 or 15 mountable - Ultra slim design with 36 mm width suitable for small chassis and narrow space installation - Safety certified according to EN 62368-1, meets the requirements of UL 61010-1, UL 508 **==> picture [29 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> RoHS<br>**----- End of picture text -----**<br> - Dimensions 36 x 125 x 100 mm (1.42 x 4.92 x 3.94 in) ## **APPLICATIONS** - Industrial control equipment - Machinery - Harsh environment applications **belfuse.com/power-solutions** LEN120 Series 2 ## **1. MODEL SELENTION** **==> picture [511 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> MAX.<br>INPUT VOLTAGE OUTPUT MAX OUTPUT MAX OUTPUT<br>MODEL EFFICIENCY [ 1] CAPACITIVE<br>RANGE VOLTAGE CURRENT POWER [ 2]<br>LOAD<br>90 - 264 VAC<br>LEN120-12 12 V 10 A 85 % 3000 µF 120 W<br>(127 - 370 VDC)<br>90 - 264 VAC<br>LEN120-24 24 V 5 A 88 % 1200 µF 120 W<br>(127 - 370 VDC)<br>90 - 264 VAC<br>LEN120-48 48 V 2.5 A 89 % 800 µF 120 W<br>(127 - 370 VDC)<br>**----- End of picture text -----**<br> 1 Typical, at 230 VAC input 2 See DERATING CURVES on page 4 ## **2. INPUT SPECIFICATIONS** All specifications are measured at Ta = 25°C, humidity <75 % nominal input voltage and rated output load unless otherwise specified. **==> picture [510 x 113] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>AC Input 90 264 VAC<br>Input voltage<br>DC Input 127 370 VDC<br>Input frequency 47 63 Hz<br>115 VAC 2.7<br>Input current A<br>230 VAC 1.6<br>115 VAC 30<br>Inrush current [ 3] A<br>230 VAC 55<br>Leakage current 240 VAC 1 mA<br>**----- End of picture text -----**<br> 3 Cold start ## **3. OUTPUT SPECIFICATIONS** All specifications are measured at Ta = 25°C, humidity <75 % nominal input voltage and rated output load unless otherwise specified. **==> picture [511 x 231] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>LEN120-12 12 14<br>Adjustable output voltage [ 4] LEN120-24 24 28 VDC<br>LEN120-48 48 55<br>LEN120-12 10<br>Output current LEN120-24 5 A<br>LEN120-48 2.5<br>LEN120-12 ± 2<br>Output voltage accuracy [ 5] %<br>LEN120-24 / LEN120-48 ± 1<br>Line regulation Rated load ± 0.5 %<br>Load regulation 0% - 100% load ± 1 %<br>LEN120-12 100<br>Ripple & noise [ 6] LEN120-24 120 mVpp<br>LEN120-48 150<br>Temperature coefficient ± 0.03 %/°C<br>Minimum load 0 %<br>115 VAC 8<br>Hold-up time ms<br>230 VAC 16<br>Switching frequency 65 kHz<br>**----- End of picture text -----**<br> 4 The output voltage can be adjusted by the output adjustable resistance ADJ, turn clockwise - 5 At full load range - 6 Measured with 20 MHz bandwidth, output parallel 47 µF electrolytic capacitor and 0.1 µF ceramic capacitor **==> picture [123 x 43] intentionally omitted <==** tech.support@psbel.com **belfuse.com/power-solutions** LEN120 Series 3 ## **4. PROTECTIONS** **==> picture [511 x 118] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>Constant current up to 1s, after 1s Hiccup mode applied.<br>Short circuit protection<br>Auto recovery. Recovery time < 3s after the SC disappear.<br>Normal / high temperature: auto recovery 105 150<br>Over current protection [ 7 ] % Io<br>Low temperature: respecting derating rules in Fig. 1, auto recovery 105<br>LEN120-12 16<br>Over voltage protection Vout latch off (restart required) LEN120-24 33 V<br>LEN120-48 60<br>OTP start 90<br>Over temperature protection °C<br>OTP release (Restart required) 60<br>**----- End of picture text -----**<br> 7 Constant current up to 1s, after 1s Hiccup mode applied. ## **5. ENVIRONMENTAL SPECIFICATIONS** **==> picture [511 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>Operating temperature -20 +60 °C<br>Storage temperature -40 +85 °C<br>-20°C to -10°C (115 VAC) 2<br>All series -20°C to -10°C (230 VAC) 0<br>Temperature derating +40°C to +60°C (115 VAC) 2.5 %/°C<br>LEN120-12 +45°C to +60°C (230 VAC) 3.33<br>LEN120-24 / LEN120-48 +50°C to +60°C (230 VAC) 5<br>Input voltage derating AC Input voltage between 90 - 115 VAC / 27 - 162 VDC 1.0 %/VAC<br>Operating, non-condescending 20 90<br>Humidity %RH<br>Storage, non-condescending 10 95<br>MTBF MIL-HDBK-217F @ 25 °C 300 000 hrs<br>**----- End of picture text -----**<br> ## **6. EMC SPECIFICATIONS** **==> picture [511 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS CLASS / LEVEL / CRITERION<br>Conducted emissions EN 55032 / CISPR 32 Class A<br>Radiated emissions EN 55032 / CISPR 32 Class A<br>Harmonic current IEC/EN 61000-3-2 Class A<br>ESD immunity IEC/EN 61000-4-2, Contact ±6 kV / Air ±8 kV Performance Criterion B<br>Radiated field immunity IEC/EN 61000-4-3, 10 V/m Performance Criterion A<br>Electrical fast transient IEC/EN 61000-4-4, ± 4 kV Performance Criterion B<br>Surge immunity IEC/EN 61000-4-5, Line to line ±2 kV / Line to ground ±4 kV Performance Criterion B<br>Conducted immunity IEC/EN 61000-4-6, 10 VRMS Performance Criterion A<br>Voltage dips, interruptions IEC/EN 61000-4-11, 0%, 70% Performance Criterion B<br>**----- End of picture text -----**<br> ## **7. SAFETY SPECIFICATIONS** **==> picture [511 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>Safety certified according to EN 62368-1,<br>Safety standards & approvals<br>meets the requirements of UL 61010-1, UL 508<br>Safety class Class I<br>Input to Ground 2000<br>Isolation test [ 8] Input to Output 4000 VAC<br>Output to Ground 500<br>Insulation resistance At 500 VDC 100 MΩ<br>8 Electric strength test for 1 min., leakage current <10 mA<br>**----- End of picture text -----**<br> **==> picture [123 x 43] intentionally omitted <==** ||**Asia-Pacifc**|**EMEA**|**North America**| |---|---|---|---| |+86|755 298 85888|+353 61 49 8941|+1 866 513 2839| |||**belfuse.com/power-solutions**|| © 2021 Bel Power Solutions & Protection BCD.20172_A 29 September 2021 LEN120 Series 4 ## **8. MECHANICAL SPECIFICATIONS** **==> picture [511 x 287] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS MIN TYP MAX UNIT<br>36 x 125 x 100 mm<br>Dimensions<br>1.42 x 4.92 x 3.94 in<br>Weight 410 g<br>Case [ 9] Material: Metal (AL1100, SGCC)<br>Cooling Convection (Natural air flow)<br>9 When the power supply is in use, the enclosure of the product needs to be connected to the system grounding.<br>9. DERATING CURVES<br>230 VAC<br>100 100<br>80 115 VAC 24 V, 48 V (230 VAC)<br>12 V (230 VAC) 75<br>Input Voltage:<br>12 V, 24 V, 48 V (115 VAC)<br>90 - 264 VAC<br>50 127 - 370 VDC Ambient Temperature:25°C<br>-20 -10 40 45 50 60<br>90 115 264 VAC<br>Ambient Temperature [°C] 127 162 370 VDC<br>Input Voltage<br>Output Power [%] Output Power [%]<br>**----- End of picture text -----**<br> Figure 1. Temperature Derating Curve Figure 2. Input Voltage Derating Curve **==> picture [485 x 149] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>95 95<br>90 LEN120-48LEN120-24 90 LEN120-48LEN120-24<br>85 LEN120-12 85 LEN120-12<br>80 80<br>75 75<br>70 70<br>65 65<br>60 60<br>90 115 230 264 10 25 40 50 65 75 90 100<br>Input Voltage [VAC] Output Current [%]<br>Efficiency [%] Efficiency [%]<br>**----- End of picture text -----**<br> Figure 3. Efficiency vs Input Voltage Derating Curve (Full Load) Figure 4. Efficiency vs Output Load Derating Curve (Vi = 230 VAC) **==> picture [123 x 43] intentionally omitted <==** tech.support@psbel.com **belfuse.com/power-solutions** LEN120 Series 5 ## **10. MECHANICAL DRAWINGS** **==> picture [497 x 424] intentionally omitted <==** **----- Start of picture text -----**<br> All dimensions are in mm [in]<br>Top View<br>General tolerance ±1.00 mm [±0.039 in]<br>Wire range 26-10 AWG<br>Tightening torque max. 0.4 Nm<br>Mounting DIN Rail TS35<br>(rail needs to be connected to safety ground)<br>6.35 [0.250]<br>100.00 [3.937]<br>4 3 2 1<br>DC ON<br>+V<br>ADJ<br>PIN FUNCTION<br>Side View Front View 1 -Vo<br>OUTPUT 2 -Vo<br>TERMINAL 3 +Vo<br>4 +Vo<br>5 AC (N)<br>INPUT<br>5 6 7 TERMINAL 6 AC (L)<br>7 *<br>GROUNDING<br>SCREW *<br>ADJ Output adjustable resistor<br>108.90 [4.288] 6.35 [0.250]<br>DC OK SIGNAL Monitors the output voltage<br>on the output terminals<br>* Pin 7 and the grounding screw are interconnected.<br> Either Pin 7 or the grounding screw need to be<br> connected to earth.<br>Bottom View Grounding<br>screw ( )<br>36.00 [1.417]<br>125.00 [4.921]<br>129.80 [5.110]<br>**----- End of picture text -----**<br> Figure 5. Mechanical Drawing **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. **==> picture [123 x 43] intentionally omitted <==** **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com/power-solutions** © 2021 Bel Power Solutions & Protection BCD.20172_A 29 September 2021
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →