Image not available
Illustrative purposes only
LDC480-48
DIN RAIL MOUNT AC - DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 248.2 € |
| Current stock | 25+ |
| Lead time | 30 days |
## LDC480 Series ## 480 W High Performance Ultracompact DIN Rail Power Supply LDC480 Series is a single phase, ultra compact DIN Rail power supply with active PFC, ideal for many applications. Its compact size, high efficiency, excellent reliability together with easy installation makes it ideal for various industrial applications. LDC480 Series is Class I isolation device designed to be mounted on DIN rail and installed inside a protective enclosure. ## **FEATURES** - Input voltage 90 - 264 VAC or 110 - 345 VDC - Output voltages 24 V, 48 V, 72 V (adjustable) - Operating ambient temperature range -40°C to +70°C (up to 60°C with no derating) - Efficiency up to 94% - Active PFC - Overload 150% - Constant Current or Hiccup mode limitation (user settable) - Easy parallelable for power increase - Extremely compact size in aluminum enclosure - Dimensions: 56 x 140 x 117 mm ## **APPLICATIONS** - Industrial control equipment - Communication - Instrumentation equipment **belfuse.com/power-solutions** LDC480 Series 2 ## **1. MODEL SELECTION** **==> picture [512 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> NOMINAL INPUT VOLTAGE OUTPUT MAX OUTPUT MAX OUTPUT<br>MODEL EFFICIENCY REDUNDANCY<br>RANGE VOLTAGE CURRENT POWER<br>LDC480-24 100 or 120 - 240 VAC 24 V 20 A 93 % 480 W<br>LDC480-24P 100 or 120 - 240 VAC 24 V 20 A 93 % Internal ORing diode 480 W<br>LDC480-48 100 or 120 - 240 VAC 48 V 10 A 94 % 480 W<br>LDC480-48P 100 or 120 - 240 VAC 48 V 10 A 94 % Internal ORing diode 480 W<br>LDC480-72 100 or 120 - 240 VAC 72 V 6.7 A 94 % 480 W<br>LDC480-72P 100 or 120 - 240 VAC 72 V 6.7 A 94 % Internal ORing diode 480 W<br>**----- End of picture text -----**<br> Discontinued models ## **2. INPUT SPECIFICATIONS** . **==> picture [511 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS SPECIFICATION<br>Nominal (UL certified) 100 or 120 - 240 VAC<br>AC Input Voltage<br>Range 90 - 264 VAC<br>DC Input Voltage 110 - 345 VDC<br>Input Frequency 47 - 63 Hz<br>Vin = 100 VAC 5.6 A<br>AC Input Current Vin = 120 VAC 4.8 A<br>Vin = 240 VAC 2.4 A<br>Vin = 110 VDC 4.9 A<br>DC Input Current<br>Vin = 345 VDC 1.7 A<br>Power Factor Correction Active > 0.9<br>Inrush Peak Current Peak Current measured after 0.2 ms from main connection; ≤ 23 A<br>I²t 240 VAC / 50 Hz; Ta = 25°C; Cold Start 0.56 A²s<br>Touch (Leakage) Current ≤ 0.9 mA<br>Internal Protection Fuse Not user replaceable 8 AT<br>It is strongly recommended to provide external surge arresters Fuse 10 AT<br>Recommended External Protection<br>(SPD) according to local regulations. or MCB 10 A C curve<br>**----- End of picture text -----**<br> ## **3. OUTPUT SPECIFICATIONS** **==> picture [511 x 210] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS SPECIFICATION<br>24 V models 22 - 29 VDC<br>Output Voltage (Adjustable) 48 V models 45 - 55 VDC<br>72 V models 70 - 85 VDC<br>24 V models 20 A<br>Output Current (Continuous) 48 V models 10 A<br>72 V models 6.7 A<br>24 V ≤ 1.5 %<br>Load Regulation<br>48 V & 72 V models ≤ 0.5 %<br>24 V models ≤ 150 mVpp<br>Ripple & Noise [ 1] 48 V models ≤ 200 mVpp<br>72 V models ≤ 350 mVpp<br>Hold-up Time ≥ 25 ms<br>DC OK - green LED<br>Status Signals OVERLOAD - red LED<br>DC OK - dry contact (NO, 24 VDC / 1 A) - Note: DC OK is not present in 72 V models<br>Possible for power or redundancy (with external ORing module)<br>Parallel Connection [ 2]<br>P models - include internal ORing diode<br>**----- End of picture text -----**<br> - 1 Ripple and Noise are measured with 20 MHz bandwidth, probe terminated with a 0.1 μF MKP parallel capacitor. 2 Pay attention, set the current limitation mode jumper on C.C. mode when connecting more units in parallel. **==> picture [62 x 33] intentionally omitted <==** tech.support@psbel.com **belfuse.com/power-solutions** LDC480 Series 3 ## **4. PROTECTIONS** **==> picture [511 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS SPECIFICATION<br>Short Circuit Protection Constant current or Hiccup mode (user settable)<br>24 V models 21 A<br>Constant current Overload Limit<br>48 V models 12 A<br>(user settable)<br>72 V models 7 A<br>Overload Protection<br>24 V models 30 A<br>Hiccup mode Overload Limit (max. 5 s)<br>48 V models 17 A<br>(user settable)<br>72 V models 12 A<br>Thermal Protection<br>Input Under Voltage Lockout<br>24 V models ≥ 33 VDC<br>Over Voltage Protection 48 V models ≥ 68 VDC<br>72 V models ≥ 100 VDC<br>**----- End of picture text -----**<br> ## **5. ENVIRONMENTAL, EMC & SAFETY SPECIFICATIONS** **==> picture [511 x 437] intentionally omitted <==** **----- Start of picture text -----**<br> PARAMETER DESCRIPTION / CONDITIONS SPECIFICATION<br>UL certified up to 50°C at 100 VAC & 120 VAC or up to<br>-40 to +70 °C<br>Operating Temperature 60°C at 240 VAC Start-up type tested: - 40°C, possible at<br>Vnom with load deration.<br>Storage Temperature -40 to +80 °C<br>Over 50°C at 100 VAC - 10.0 W/°C<br>Derating Over 50°C at 120 VAC - 7.6 W/°C<br>Over 60°C at 240 VAC - 7.2 W/°C<br>24 V models < 36.5 W<br>Dissipated Power<br>48 & 72 V models < 31 W<br>Humidity Non-condescending 5 - 95 % RH<br>Life Time Expectancy Ta = 25°C, full load 167 953 (19.1) hrs (years)<br>MTBF MIL-HDBK-217F at Ta = 25°C, full load > 600 000 hrs<br>Overvoltage Category EN 50178 III<br>Pollution Degree IEC 60664-1 2<br>Protection Class Class I<br>Input to Output 4.2 kVDC<br>Isolation Input to Ground 2.2 kVDC<br>Output to Ground 0.75 kVDC<br>UL 508 (certified)<br>Safety Standards & Approvals UL 61010-1 (certified)<br>EN 61010-1 (meet the requirements)<br>EN 55011 / CISPR 11 Class B<br>EMC Emissions EN 61000-3-2 Class A<br>EN 61000-3-3<br>EN 61000-4-2 Level 3 (Air) Level 2 (Contact)<br>EN 61000-4-3 Level 3 (80-1000 MHz) Level 2 (1.4-6 GHz)<br>EN 61000-4-4 Level 3<br>EMC Immunity EN 61000-4-5 Level 3<br>EN 61000-4-6 Level 3<br>EN 61000-4-8 Level 4<br>EN 61000-4-11 Level 2<br>Protection Degree EN 60529 IP20<br>5 - 17.8 Hz: ±1.6 mm; 17.8 - 500 Hz:<br>Vibration Sinusoidal IEC 60068-2-6<br>2 g 2 hours / axis (X,Y, Z)<br>30 g 6 ms, 20 g 11 ms;<br>Shock IEC 60068-2-27<br>3 bumps / direction, 18 bumps total<br>**----- End of picture text -----**<br> **==> picture [62 x 33] intentionally omitted <==** **Asia-Pacific EMEA North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 **belfuse.com/power-solutions** © 2024 Bel Fuse Inc. BCD.00757_AJ 24 January 2024 LDC480 Series 4 ## **6. MECHANICAL SPECIFICATIONS** |**PARAMETER**|**DESCRIPTION / CONDITIONS**<br>**SPECIFICATION**|**DESCRIPTION / CONDITIONS**<br>**SPECIFICATION**| |---|---|---| |Dimensions|56 x 140 x 117<br>2.2 x 5.5 x 4.6|mm<br>in| |Weight|1100|g| |Mounting Rail<br>Connection Terminals<br>Case Material|IEC 60715/H15/TH35-7.5(-15)<br>Screw type pluggable (24 - 12 AWG)<br>2.5 <br>Aluminum|mm²| Figure 1. Mechanical Drawing ## **7. PIN LAYOUT & DESCRIPTION** **PIN DESCRIPTION** 1 AC/DC input 2 DC output (load) I * OVERLOAD Diagnostic Output (dry contact, NO, 24 VDC / 1 A) 3 7 D) vo aa. ( **Note:** Not present on 72 V models) Tt seew 4 Green LED: Output OK =; —+ =24V, 20A 5 Red LED: Overload ; + OUTPUT 6 Output voltage adjustment 7 Selectable limitation mode (Hiccup mode, C.C. mode) | LDC480-24 **INPUT CONNECTION Single phase DC Input** KY pe oK L = Line L =+ Positive DC N = Neutral N = - Negative DC ~~-]~~ © input **OUTPUT CONNECTION** + = Positive DC[= Earth ground][= Earth ground] 50-60 Hz - = Negative DC |; 1 **SIGNALLING** DC OK: dry contact (Not present on 72 V models) • NO =” • COM ## **Notes:** Technical parameters are typical, measured in laboratory environment at 25°C and 240 VAC / 50 Hz, at nominal values, after minimum 5 minutes of operation. Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range. Contact factory for details. **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. tech.support@psbel.com **belfuse.com/power-solutions**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →