Image not available
Illustrative purposes only
FX3U-32BL
LITHIUM MANGANESE DIOXIDE BATTERY, PLC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MITSUBISHI
- Product type: Controller Accessories
- SVHC: No SVHC (10-Jun-2022)
- Product Range: MELSEC FX3U
- Current Rating: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 58.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
**FX Family MELSEC PLC**
**The world’s favorite micro PLCs**
**13 Million FX PLCs Worldwide / Over 30 Years Experience / Expanded Micro PLC Control / Networking Solutions / Analog Solutions / Positioning Solutions /**
Global leader
## **Global Leader**
The MELSEC FX3 series are the third generation on programmable controllers of the Mitsubushi Electric FX family. They offer improved network capability and solutions for positioning tasks.
## **13 Million FX**
The FX Family of PLCs is the PLC of choice across the world, industries and applications. Mitsubishi Electric has always worked closely with its customers to design the PLC that they want for their applications. The manufacturing and use of 13 million FX CPUs is a demonstration that this close working relationship has delivered quality, reliability and the product that customers want.
The FX Family has proven to be highly reliable and it consistently improves its compatibility with previous PLC generations.
## **Number 1 in the world**
Mitsubishi Electric was shown to be the largest volume producer of PLCs in the world following the 2004 Worldwide PLC survey by the respected American automation research company ARC.
## **Over 30 Years**
The FX Family of PLCs has been an important part of control engineering for over 30 years. Throughout its history, the product has evolved from the original F series into today’s current FX3 series.
ARC is protected by ARC Advisory Group copyright 2004
2
Contents
## **Contents**
What makes a world leading PLC? 4–5 ~~mz~~ Range overview 6 ~~EE~~ FX3U/FX3UC, a new concept in PLCs 7–9 ~~Ee~~ FX3G/FX3GC, an automation standard 10 ~~ze~~ FX3GE – the versatile PLC 11 ~~nS~~ FX3S – micro control 12 ~~|.~~ Programming and software 13 Networking 14 Analog solutions 15 ~~—~~ (ss ~~ne~~ 2 Positioning solutions 16 ~~—~~ i|Displays solutions 17 ~~—~~ Applications 18 ~~—~~ Clk
Section 2: Technical Informations
3
World leading PLCs
## **What makes a world leading PLC range?**
**Global use** Wide range power supply means your FX solution will work all over the world. eT =
Memory cassette port is located under the removable front cover. Adapter or “ADP” units are used on the left hand side of the main PLC unit. NY
**==> picture [96 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
International a &<br>**----- End of picture text -----**<br>
## **International acceptance**
Shipping approvals such as Lloyds, German Lloyds, ABS, RINA, Det Norse Vetaritas, for example plus CE and E1 compliance for Low Voltage and EMC directives as well as manufacturing to Automotive industry quality levels, make the FX Family PLCs products to trust.
Optional communication boards are available in USB, RS232C, RS422 The RUN/STOP switch has and RS485 formats. become a familiar feature with all FX Family PLCs.
**==> picture [113 x 29] intentionally omitted <==**
**----- Start of picture text -----**<br>
The standard RS422 Mini-DIN<br>programming port can also be<br>used for HMI connection.<br>**----- End of picture text -----**<br>
## **Flexible design**
The FX Family is designed so that the main PLC CPU acts as a platform to which you can add and customize the special functions you need – making every FX your personal PLC.
4
World leading PLCs
Main base unit where CPU, I/O and power supply are contained in a single unit.
All FX PLC units can be mounted on a DIN rail or directly mounted with screw fixings.
## **Easy Programming**
The FX Family incorporates an easy programming concept where several complex tasks can be reduced to a single instruction.
## **Fast and reliable**
FX PLCs continually push the limits of high speed operation to process your applications more effectively and accurately.
Simple ribbon connection links each unit together.
Special function blocks can be added to the right hand communications bus of the PLC.
## **Compatibility**
Bright LED lamps indicate I/O and power status.
The FX Family of PLCs continues to raise the level of backward compatibility with many existing FX PLC programs being transferable. And in later models, sharing common peripherals and special function blocks means even greater protection for your investment in both FX and the machine or process being controlled.
5
The power to perform
## **The power to perform**
## **FX3U/FX3UC**
Ultra high speed, maximum performance and a simplified design concept make this the ultimate micro PLC.
## **FX3G/FX3GC/FX3GE**
**FX3G/FX3GC/FX3GE** Advanced control, multiple communication possibilities and a wide range of options make this PLC an industry leader. oso Feel— e:iC **FX3S** A compact micro controller for simple applications, supported by a strong communications capability. **I/O** (nr
The FX Family of PLCs builds on previous performance and capability, ensuring you have a comprehensive range of control and automation options to choose from.
## **A solution for every application**
Micro PLCs have opened up a world of opportunities in Industrial Automation due to their small size and low cost. Now many applications benefit from enhanced performance, easier manufacturing, maintenance and greater reliability.
The FX Family has been a part of this revolution for over 30 years and has developed and redeveloped a range of products to suit most applications. The FX Family consists of six main ranges which are distinct and independent but compatible.
Depending on your application and control needs, you can choose from the small, economical standalone FX3S series and the powerful FX3G, FX3GC, FX3GE, FX3U and FX3UC series.
With the FX Family there really is a solution
to most applications.
|Power supply|100–240 V AC<br>30<br>Relay/Transistor<br>0,21 µs/logical instruction<br>16 k steps|100–240 V AC, 24 V DC<br>256**<br>Relay/Transistor<br>0,21 µs or 0,42 µs/logical<br>instruction<br>32 k steps|24 V DC<br>256**<br>Transistor<br>0,21 µs or 0,42 µs/logical<br>instruction<br>32 k steps|100–240 V AC, 24 V DC<br>256**<br>Relay/Transistor<br>0,21 µs or 0,42 µs /logical<br>instruction<br>32 k steps|100–240 V AC, 24 V DC<br>384*<br>Relay/Transistor<br>0,065 µs<br>64 k steps|24 V DC<br>384*<br>Transistor<br>0,065 µs<br>64 k steps|
|---|---|---|---|---|---|---|
|Maximum I/O|||||||
|Digital I/O|||||||
|Cycle period/logical instruction|||||||
|PLC program memory|||||||
Summary table of FX PLCs Note * : When networked with CC-Link (Discrete I/O, maximum 256) Note **: When networked with CC-Link (Discrete I/O, maximum 128)
6
FX3U a perfect PLC concept
## **FX3U a perfect PLC concept**
The FX3U CPU brings a combination of greater flexibility and increased performance to the FX Family.
## **High performance**
Thanks to the flexible expansion options of the FX3U series, the PLC can be optimally adapted to the respective requirements.
Following the standard FX Family configuration, the FX3U CPU can be expanded to the right hand side using a wide range of options. These include input and output blocks as well as special function blocks such as analog, pulse train and network communication units.
The FX3U series has a fast communications bus that automatically switches into high speed mode and handles the communication with increased speed, when the new FX3U expansion modules are connected.
Full compatibility is still available with FX2N and FX0N expansion blocks, and when these are configured the FX3U automatically reduces the bus speed to suit.
This means greater support for existing installed systems as well as delivering high performance and greater response with new installations.
## **Adapters add flexibility**
An outstanding performance feature of the FX3U is the adapter expansion bus on the left hand side of the base unit. Through this bus users can add additional analog and temperature units as well as multiple communications and positioning blocks.
However, the major benefit for the user is that the analog and positioning adapter units no longer require the use of the traditional To/From instruction to configure and operate.
All control is through direct access data registers and setting bits. This means quicker setup, easier use, and above all much higher processing speeds.
FX3U has a unique new system of directly programmable adapters.
The FX3U can use FX3U expansion modules as well as standard FX2N and FX0N expansion modules.
7
FX3U/FX3UC a perfect PLC concept
## **FX3U/FX3UC. More power. More performance.**
**==> picture [484 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U/FX3UC Base Unit Expansion I/O<br>A Maximum<br>+ Network master System Maximum<br>256 I/O<br>384 I/O<br>B Remote I/O Remote I/O Remote I/O Maximum A + B <= 384<br>Remote network stations 256 I/O<br>S| S e |<br>**----- End of picture text -----**<br>
FX3U/FX3UC provides additional I/O and networking capacity.
**FX3U/FX3UC FX2N Basic 0.065 µs** _**FAST**_ **instrucion** ~~=~~ **0,08 µs Applied 0.642 µs** _**FAST**_ **instruction (MOV)** ~~a~~ **1,52 µs**
FX3U/FX3UC provides increased performance in all areas.
Note: 4.5 times increase in speed is measured under the following conditions: program capacity = 16 k step, with an I/O usage of 144 points. Program scan time is then; FX3U/FX3UC: 4.6 ms and FX2N: 21.0 ms, an increase in processing speed of 4.56 times.
**==> picture [155 x 55] intentionally omitted <==**
**----- Start of picture text -----**<br>
7680 points FX3U/FX3UC<br>Auxilliary Relay (M) 3072 points FX2N<br>4096 points<br>State Flags (S)<br>1000 points<br>Timers (T) 512 points<br>256 points<br>Data Registers (D) 8000 Adressen40768* points *Includes R Registers<br>**----- End of picture text -----**<br>
FX3U/FX3UC offers increased resources as well as increased performance.
## **Increased I/O capacity**
With enhanced networking functions, the FX3U/FX3UC requires an increased input/ output (I/O) range. FX3U/FX3UC can support systems with combined local I/O and networked I/O up to a total of 384 I/O points. For users, this means increased system control and added possibilities for advanced networks.
In addition FX3U/FX3UC also fully supports Profibus DP as well as Ethernet using TCP and UDP protocols.
## **Up to 4.5 times faster**
The time that is required for the execution of instructions in the FX3U/FX3UC is dramatically reduced. This means a logical instruction is being processed in only 0.065 µsec.
For users this means quicker program response and more accurate process performance as inputs, outputs and actions are processed and monitored more times per second.
## **8 times more memory**
The FX3U/FX3UC comes with a standard internal memory of 64 k steps, which is 8 times more memory than in the previous model.
More memory means users can write larger and more complex programs, store more data in file registers, or take greater advantage of using IEC 61131-3 style programming tools.
## **5 times more data storage**
With a larger program memory comes the need for more operational devices such as timers, state flags, auxiliary relays and data registers. The FX3U/FX3UC has increased capacity in all of these major areas making program construction easier. Data register capacity has increased by a factor of 5 reflecting the needs of users who have an increased requirement to log operation information against products or batches of products being manufactured.
A typical example of this can be found in the Food and Pharmaceutical industries. Here exact process data such as oven temperatures and cooking times or quantities of ingredients mixed need to be stored against production batches – all this requires increased data handling and data capacity within the PLC.
## **75 new instructions**
Compared to the previous model, the FX3U/ FX3UC offers with 75 new instructions an enormously enhanced programming instruction set. A total of 209 instructions are available. All of the instructions follow the traditional FX Applied instruction concept designed to make the task of application building and program writing easier and quicker, with less chance for errors.
8
FX3U/FX3UC a perfect PLC concept
RS485
**==> picture [207 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
RS232 GOT<br>RS422<br>USB<br>**----- End of picture text -----**<br>
Adapter modules increase positioning performance.
**==> picture [213 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Inverter multidrop<br>Inverter 1 Inverter 8<br>**----- End of picture text -----**<br>
New instructions include greater control over data processing with a range of new comparison and string manipulation commands. **LOGE (Nr. 125)** Inverter 1 Inverter 8 Calculates the natural logarithm in floating point FX3U/FX3UC has a range of flexible communication options. **SORT2 (Nr. 149)** Sort tabulated data **TBL (Nr. 152) A great communicator** Batch data positioning mode FX3U/FX3UC has strengthened the commu- **at a glance BAND (Nr. 257)** nications capability of the FX Family even Defines a band or range of valid further. **I/O range** numbers The new adapters allow up to three RS **IVWR (Nr. 273)** communication channels to be operated **Program memory** Write parameter to inverter simultaneously allowing multiple HMIs a Hae 6G to be connected to a single FX3U/FX3UC Some examples of instructions from the FX3U/FX3UC. CPU or combinations of HMIs, third party devices and programming tools – the choice is yours. **Simple high speed** The FX3U/FX3UC also supports a wide range **positioning** of network options including Modbus,
**A great communicator FX3U/FX3UC** FX3U/FX3UC has strengthened the commu- **at a glance** nications capability of the FX Family even further. **I/O range** The new adapters allow up to three RS 16–384 (Discrete I/O, maximum 256) communication channels to be operated **Program memory** simultaneously allowing multiple HMIs 64 k steps (standard) to be connected to a single FX3U/FX3UC **Basic instruction processing** CPU or combinations of HMIs, third party 0.065 µsec/logical instruction
## **Analog signal processing**
Up to 80 analog inputs, Up to 48 analog outputs
The FX3U/FX3UC also supports a wide range of network options including Modbus, Profibus DP, CC-Link, DeviceNet, CANopen as well as Ethernet.
**Analog resolution** 8, 12 and 16 bits
The FX3U/FX3UC has been designed with six high speed counters that can each count up to 100 kHz simultaneously per channel. This, combined with three 100 kHz pulse train outputs, means users can directly configure simple 3-axis positioning systems without the use of additional modules.
## **Analog options**
The FX3UC is the ideal choice for applications where there is not much space for the controller hardware. The smallest base unit with 8 digital inputs and 8 transistor outputs takes up just 27 % of the space required for a comparable FX3U unit – and yet the FX3UC incorporates all the features of the FX3U.
19 analog input, output and temperature blocks available for selection
**Positioning** Internal:
6 high speed counters (100 kHz) 2 high speed counters (10 kHz) 3 pulse train outputs (100 kHz), transistor unit only External (FX3U only): High speed counter block (50 kHz) High speed counter ADP module (200 kHz) Pulse train ADP (200 kHz) Pulse train output block (1 MHz)
However, the new high speed counter ADP and pulse train ADPs can provide the FX3U/ FX3UC with maximum positioning performance. Each unit can process signal speeds of up to 200 kHz.
The connections for the FX3UC inputs and outputs on the front side can be wired with ribbon cable connectors. For this purpose system cabling sets and remote I/O terminal blocks for easy and fast connections are available.
9
FX3G/FX3GC series powerful micro control
## **FX3G/FX3GC – an industry standard**
## **The great communicator**
With a wide range of network and serial protocols available, such as Ethernet, CC-Link and Modbus, the FX3G/FX3GC enables seamless integration and data communications between both Mitsubishi Electric and thirdparty devices. Furthermore, a builtin USB port permits convenient connection to any PC or laptop.
## **FX3G/FX3GC at a glance**
**I/O range**
14–256 (Discrete I/O, maximum 128)
FX3G/FX3GC PLCs are used in many applications for processing and packaging as well chilled storage and transportion of food items.
**Program memory** 32 k steps (internal)
## **Basic instruction processing**
0.21 µs or 0.42 µs/logical instruction
Since its launch, the FX3G has been a standard of micro PLC control.
FX3G/FX3GC has the versatility to handle applications from a wide range of industries.
## **Customized control**
The FX3G/FX3GC is an introductory compact PLC and is the addition to the FX3 series, designed for simple yet performance critical applications that require discrete control of up to 128 local I/O or up to 256 I/O with CC-Link remote I/Os. Incorporating innovative FX3 series technology the customer is presented with a suite of benefits. These include a large program memory to implement sophisticated algorithms plus high speed execution to enhance system productivity.
## **Highly flexible**
A dual bus architecture provides flexible expansion possibilities and with the ability to handle analog, high speed, positioning, and inverter control, the FX3G/FX3GC is able to successfully adapt to a range of applications in industry areas such agriculture, water processing, material handling, food processing and more.
**Analog signal processing** Up to 74 analog inputs Up to 41 analog outputs
## **Analog resolution**
8, 12 and 16 bit
## **Analog options**
19 analog input, output and temperature blocks available for selection
## **Positioning**
Internal: Up to 4 high speed counters (max. 10 kHz) up to 2 high speed counters (max. 60 kHz) up to 3 (2) pulse train outputs (100 kHz)
10
FX3GC series powerful micro control
## **FX3GE – the versatile PLC**
The FX3GE series is the most versatile com-pact PLC from Mitsubishi Electric and introduces yet another top model to the FX3 range. In addition to the powerful functions of the FX3G series, the FX3GE also boasts integral analog inputs/outputs and Ethernet connectivity. Other features include an RS422 interface and an USB programming port. The FX3GE therefore sets new class standards for compact PLCs; it provides excellent value for money, and is ideally suited for many applications. Typical fields of use include the foodstuffs industry, processing machines, packaging technology, pumps and refrigeration systems.
## **Strong performance**
For processing analog values, the FX3GE comes as standard with two analog inputs and one analog output, each having a resolution of 12 bits (0–4000). The FX3GE also features an Ethernet port with a transmission rate of 100/10 Mbit/s. The Ethernet port is ideal for programming and monitoring and for making online modifications. It also enables the unit to be connected to graphical operating panels (HMI), such as Mitsubishi Electric‘s GOT series. With this Ethernet port, the FX3GE also provides a facility for monitoring process values using a web browser. The PLC can therefore be maintained and monitored regardless of where the FX3GE is installed. Appropriate access rights can be assigned using different password levels.
Sequence control in the food industry
## **FX3GE at a glance**
**I/O range** 24–256 (Discrete I/O, maximum 128)
**Program memory** 32 k steps
**Basic instruction processing** 0.21 µs or 0.42 µs/logical instruction
**Analog signal processing** Up to 74 analog inputs Up to 41 analog outputs
**Analog resolution** 8, 12 and 16 bit
Builtin Ethernet interface
## **Analog options**
19 analog input, output and temperature blocks available for selection
**Positioning**
Internal: Up to 4 high speed counters (max. 10 kHz) up to 2 high speed counters (max. 60 kHz) up to 3 (2) pulse train outputs (100 kHz)
Monitoring via the web interface
11
FX3S micro control
## **FX3S micro control**
## **Fit and forget**
Typically FX3S applications are small, embedded control functions that are hidden away or unaccessible under normal maintenance activities. This is why the FX3S has been designed to be a robust low maintenance PLC. Features such as the maintenance free, 4000 step EEPROM memory and real time clock management all help to make the FX3S a self managing system, reducing the impact on the maintenance engineer.
## **Remote control**
The FX3S has an additional range of BD expansion boards providing RS232, RS485, RS422 or Ethernet communications options. These can be used to connect and control various third party products such as bar code readers or panel printers.
## **FX3S at a glance**
**I/O range** 10–30
**Program memory** 4 k steps (standard)
FX3S has been used in a wide range of embedded control applications.
The FX3S series PLC provides full function PLC control, builtin highspeed inputs and outputs, either relay or transistor outputs, and multiple, builtin communication ports. It also includes expansion options for communications, analog, and temperature control. The FX3S-30MT/ESS-2AD and FX3S-30MR/ES-2AD comes also with two builtin analog inputs (0–10 V DC). In addition, optional expansion possibilities for communication, analog or temperature value processing are available. As part of the FX3 series, the FX3S can use many of the existing programming resources that are available for other FX3 series PLCs. This greatly reduces time and costs for system set up.
FX3S offers communication and real time control from a single unit.
**Basic instruction processing** 0.21 µs/logical instruction
**Analog signal processing**
FX3S-30Mm/m-2AD; 2 integrated analog inputs FX3S-mMm/m; 2 analog inputs or 2 analog outputs optionally
**Analog resolution** 12 bit
**Analog options**
2 analog input BD board 1 analog output BD board
**Positioning**
Internal:
2 high speed counters 60 kHz, 4 high speed counters 10 kHz 2 pulse train outputs (100 kHz), transistor unit only
12
Programming
## **Progressive software concepts**
The Mitsubishi Electric FX PLC Family has a worldwide reputation for reliability, performance and ease of use. These key values have also been used to form Mitsubishi Electric’s integrated software concept, MELSOFT.
## **Simple programming**
The FX Family has a simple programming structure combining Basic and Applied instructions. The Basic instructions are common to all FX Family PLCs. Applied instructions provide the specialist control options such as data comparisons, PID and communications control, all of which are available on FX series. By the graded performance of each PLC series of the FX family, the number of available application instructions increases.
## **Productivity tools**
Programming software for PLCs is constantly evolving. Users are placing more focus on reusable program code and function block concepts. This helps to reduce errors, reduce programming time and to help manage the whole programming process – increasing overall productivity.
## **Simple and intuitive**
## **Choose what you need**
GX Works2 offers users the chance to program all Mitsubishi Electric MELSEC PLCs from a single package. However, for users who only need support for FX based systems there is GX Works2 FX.
Mitsubishi Electric provides with GXWorks2 IEC 61131-3 compliant programming, where programs in Instruction List, Ladder, Function Block, Structured Text or SFC formats can be created. Using standard programming languages, like IEC 61131-3, on large programming projects can help users save costs by creating reusable PLC code and Function Blocks.
## **One step further with iQ Works**
With the software suite iQ Works Mitsubishi Electric offers an integrated engineering environment. The intuitive user interface allows you to program and set up an iQ Platform, including system and network configuration, the programming of the MELSEC System Q, the MELSEC L series and the FX series, the establishment of motion controllers and servos, the design of user interfaces for operator panels of the GOT family as well as the programming of robots with the RT ToolBox2.
**==> picture [161 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
MELSOFT is a wide range of software solutions<br>designed to optimize your plant productivity.<br>**----- End of picture text -----**<br>
Often the biggest cost on a project is engineering time.
The key to any good software is that it is simple to use. Mitsubishi Electric’s GX Works2 PLC programming packages have achieved this by using intuitive design.
GXWorks2 offers also comprehensive help functions and an advanced communications layer, ensuring safe reliable communication to the target PLC.
GX Works2 offers ease of use for programmers of all skill levels.
13
Networking solutions
## **Networking and communication solutions**
## **Remote maintenance**
With communications technology it is now possible to put PLC control in the most remote locations. Using a PLC with a RS232 interface to a telemetry solution, such as a GSM modem, allows the user the ability to remotely monitor and maintain the system. It can also allow the remote system to send alarm messages, warnings or general status information back to the user’s central data processing centre.
## **Easy communications**
FX Family PLCs have a wide range of communications options.
Applications are often required to integrate between each other across a factory, to report production or tracking data back for office based processing and in some cases be remotely monitored and maintained when the application is in an inaccessible location. The FX Family of PLCs has evolved to match this demand at all levels.
## **Networks make sense**
Example of remote pumping station.
Today’s FX Family of PLCs share a basic communication concept where additional RS232, RS422 or RS485 communications boards can be added to the main base unit without increasing the required cabinet space. These can then be used for communication to various third party devices like bar code readers, printers and modems.
FX3 Family PLCs have a wider range of communications modules. These include options for connection to open and bespoke networks such as Ethernet, Profibus DP, CC-Link, DeviceNet, CANopen or Modbus for example.
Networked solutions to complex applications often make the overall solution easier to achieve and more cost effective. For example a conveyor system integrated with a warehouse pick and place system may extend over many hundreds of meters, and by using a fieldbus, such as CC-Link, wiring, troubleshooting and maintenance can be dramatically reduced.
14
Analog solutions
## **Analog solutions**
Analog control is one of the most important areas for any automation system. Critically for users the concern is to match the performance demanded by the application to the available solutions in a cost effective way.
Inverter
Example: D-A control can be used to set the speed of an inverter driving a motor.
## **Where is analog used?**
Analog control is widely used. In simple terms it allows a variable signal to be used to control items such as a motor’s speed or to sense inputs such as fluid levels.
## **Digital to analog (D-A) control**
Here a digital PLC value is output as an analog signal. It can be used, for example, to send a speed command to an inverter which in turn causes the motor to increase or decrease speed.
## **Analog to digital (A-D) control**
In this type of control a variable signal is sent to a PLC where it is converted in to a direct digital value. An example of this could be the measurement of the level of a liquid in a storage tank so that the exact amount of stored liquid can be controlled by the PLC.
Example: Temperature control keeps the liquid at the correct viscosity.
Example:
A-D control can be used to control the filling speed of the container.
## **Temperature control**
Temperature control is the third type of analog control. An example of use could be where the temperature of a furnace is measured and compared by the PLC against a set range. Additional heating or cooling can then be applied to maintain a constant temperature.
Analog solutions are an important part of control engineering and can be used to simplify and accurately control actions happening in the production environment.
## **24 solutions to choose from**
The FX Family offers a wide range of analog solutions from 1 and 2 channel BD boards for FX3G up to 8 channel input blocks like the FX2N-8AD where temperature, voltage and current input can be mixed on the same block. FX analog blocks also come in a range of resolutions from 8 bit up to 16 bit signal processing. Overall there are 24 different analog options available to users of the FX PLC Family.
With this range of choice and flexibility it is sure that there will be a solution here for most applications.
Example of temperature control.
15
Networking solutions
## **Positioning solutions**
**==> picture [101 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
X-Y table for simple shaping<br>**----- End of picture text -----**<br>
| **Pulse train outputs**
A stream of output pulses can be used as a drive signal to a line driver, stepper motor or servo amplifier, which then causes the connected motor to perform the positioning activity.
The larger the range of output pulse frequencies available means greater speed and/or accuracy is achievable. For example, if a stepper motor with a larger number of steps is used, the travel distance per step can be reduced, resulting in an increased system accuracy.
## **High speed counter input**
When a motor is being driven, its relative position can be controlled by counting the number of output pulses.
**==> picture [264 x 23] intentionally omitted <==**
**----- Start of picture text -----**<br>
Horizontal<br>Vertical<br>drill station<br>drill station<br>**----- End of picture text -----**<br>
However, for a more accurate process, reading the actual position from an encoder feedback directly into a high speed counter is preferred. This helps to overcome issues of backlash and slippage as the actual position is measured and not assumed.
## **Positioning built in as standard**
Simple positioning solutions can be effectively managed within a standard FX PLC.
Using simple positioning solutions can help increase the accuracy of the work process, reduce waste and rework as well as provide a higher quality of production.
## **Typical applications**
Simple positioning applications typically involve independently controlled operational axis and can sometimes have many requirements. In the example of an X-Y table, a relative position is achieved by driving each axis until its target position is achieved, regardless of what happens with the other axis. There are two main elements to achieve this type of positioning control.
Example of conveyor belt control.
FX PLCs come with high speed counters (in some cases up to 100 kHz) and pulse train outputs (also in some cases up to 100 kHz) as standard. The high speed counters can be configured in single pulse train inputs, The high speed counters can be configured in a single or two phase input. Pulse train outputs can be configured to provide continuous pulse streams at different frequencies or a set quantity of pulses at a single frequency.
There are also optional modules and adapters that can provide additional high speed counters with performance up to 200 kHz. The same is true for pulse train outputs with 200 kHz and 1 Mpps (1 MHz) output options available.
16
GOTs / Displays
## **Display solutions**
An increasingly important area of any automation solution is the reporting and display of operational information. This data enables operators, maintenance teams and business managers to make informed decisions in the best interests of the business.
Access to this data could be through the machine operator’s terminal, across a network or through a dedicated display mounted inside or on the control cabinet itself.
## **The business manager**
## **The right tool for the right job**
For maximum efficiency, each user requires access to information at their work place in a form that highlights the important data for them first. This means a range of different tools are required. As an example, here are three possible scenarios. =
## **The machine operator**
Machines often have a lot of manufacturing debris around or are subject to hygienic cleaning as in the food industry. Any display located in this environment would need to have a high Ingress Protection (IP) rating, indicating a high degree of waterproofness.
It may also be a benefit to the operator to have a large and clear display to reduce the chances for error from misreading, due to poor light or small fonts being used. It is also recognized that the use of graphics also reduces the chances for reading errors with complex data.
In a production controllers office it would be better to display information through a network to their existing desktop PC. In this application a piece of software such as an OPC server/client, a Java applet, an Active X control or a SCADA system would allow lots of data from lots of sources to be displayed in a clear and concise way giving the production controller the overview of the business operation that they need.
## **Data the way you want it**
Mitsubishi Electric offers a wide range of visualization solutions from simple data displays such as the FX3U-7DM, advanced Graphic Operator Terminals like the GOT series, and a wide choice of software solutions from the MELSOFT software suite.
This powerful combination of hardware and software means there is a cost effective solution for most applications.
In the food industry hygiene is very important.
The FX3U-7DM can be directly mounted within the PLC (FX3U) or mounted on the front cabinet.
## **The maintenance team**
The critical information for a maintenance engineer is the error and diagnostic data within the PLC as this is used to diagnose any process problems. However, additional information regarding the operational “hours run” or cycles processed, which could be called soft information as it is calculated on operational parameters, could allow the maintenance engineer to predict possible failure and arrange preventative maintenance.
The GOT is a typical HMI
17
Application solutions
## **Where have FX PLCs been used?**
- Food and drink – Bread manufacture (mixing/baking) – Food processing (washing/sorting/ slicing/packaging)
## Leisure
- Multiplex cinema projection
- Animated mechatronics
(museums/theme parks)
Medical
- Respiration machine testing
- Sterilization
Pharmaceutical/chemical
- Dosing control
- Polution measurement systems
- Cryogenic freezing
- Gas chromotography
- Packaging
## Plastics
- Plastic welding systems
Sanitation management on Eurostar rollingstock.
Swimming pools are managed using FX PLCs.
Customer applications with FX PLCs have been wide spread from critical applications in pharmaceutical industries to sublime applications in the leisure industry. However, the FX PLC Family still remains the PLC of choice for many machine builders as it is flexible, compact and easy to use, which is why it is so often used.
Here are just a few examples of applications that customers have completed in the past
## Agriculture
- Energy management systems for injection molding machines – Loading/unloading machines
- Blow molding test machines – Injection molding machines
Printing
## Textiles
## Transportation
- Sanitation on passenger ships
- Sanitation on rail rolling stock
- Fire tender, pump management
- Waste disposal truck management
Utilities
- Waste water treatment
- Fresh water pumping
- Plant watering systems – Plant handling systems – Saw mill (wood)
Building management
- Smoke detection monitoring
- Ventilation and temperature control
- Lift (elevator) control
- Automated revolving doors
- Telephone management
- Energy management
- Swimming pool management
Construction
- Steel bridge manufacturing
- Tunnel boring systems
18
ALPHA FX3S FX3G FX3GC FX3GE FX3U FX3UC
## **Technical Information Section**
## **Further Publications within the Industrial Automation Range**
## **Q/L Family**
##
Product catalogues for programmable logic controllers and accessories for the further MELSEC PLC series
## **HMI Family**
Product catalogue for operator terminals, supervision software and accessories
## **FR Family**
Product catalogue for frequency inverters and accessories
## **MR Family**
Product catalogue for servo amplifiers and servo motors as well as motion controller and accessories
## **Robots Family**
Product catalogue for industrial robots and accessories
## **LVS Family**
Product catalogue for low voltage switchgears,magnetic contactors and circuit breakers
## **Automation Book**
Overview on all Mitsubishi Electric automation products, like frequency inverters, servo/motion, robots etc.
## **More information?**
This product catalogue is designed to give an overview of the extensive range of FX Family of MELSEC PLCs. If you cannot find the information you require in this catalogue, there are a number of ways you can get further details on configuration and technical issues, pricing and availability.
For technical issues visit the https://eu3a.mitsubishielectric.com website. Our website provides a simple and fast way of accessing further technical data and up to the minute details on our products and services. Manuals and catalogues are available in several different languages and can be downloaded for free.
For technical, configuration, pricing and availability issues contact our distributors and partners. Mitsubishi Electric partners and distributors are only too happy to help answer your technical questions or help with configuration building. For a list of Mitsubishi Electric partners please see the back of this catalogue or alternatively take a look at the "contact us" section of our website https://eu3a.mitsubishielectric.com.
## **About this product catalogue**
This catalogue is a guide to the range of products available. For detailed configuration rules, system building, installation and configuration the associated product manuals must be read. You must satisfy yourself that any system you design with the products in this catalogue is fit for purpose, meets your requires and conforms to the product configuration rules as defined in the product manuals.
Specifications are subject to change without notice. All trademarks acknowledged.
© Mitsubishi Electric Europe B.V., Factory Automation - European Business Group
**The products of Mitsubishi Electric Europe B.V., that are listed and described in this document, are neither subject to approval for export nor subject to the Dual-Use List.**
2
Contents
## ~~**System Description**~~
|�|ALPHA and MELSEC PLC system 4|
|---|---|
|�|Features FX series 5|
|�|Components for an FX PLC system 6|
|�|Calculation of the power consumption 7|
|~~**1**~~|~~**ALPHA Controllers**~~|
|�|Base units 8|
|�|Extension units and accessories 11|
## ~~**2 MELSEC FX Base Units**~~
� FX3S series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 � FX3G series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 � FX3GE series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 � FX3GC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 � FX3U series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 � FX3UC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
## ~~**3 MELSEC FX Extension Units**~~
� Powered compact extension units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 � Modular extension units without power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
## ~~**4 MELSEC FX Special Function Modules**~~
� Analog modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 � Temperature control modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 � Data logger modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 � High-speed counter modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 � Positioning modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 � Network modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 � Communications modules, Interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 � Adapter boards and communications adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 � Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
~~**1**~~
~~**2**~~
~~**3**~~
~~**4 5 6**~~
~~**7**~~
~~**5 Accessories**~~ � Expansion adapter/Memory media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 � External terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 � Power supply units/Backup batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 � Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 � Display modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
## ~~**6 Dimensions**~~
� ALPHA series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 � Base and extension units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 � Special function modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 � Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
## ~~**7 Software & Programming**~~
|�|Trainings and programming software 62|
|---|---|
|�|Programming unit 65|
|�|Approvals 66|
|�|Index 68|
3
System Description
## **ALPHA and MELSEC PLC systems**
## **The ALPHA series**
The ALPHA closes the gap between single components and a PLC system. It combines all advantages of a PLC system in a very compact housing and therefore provides a space and cost saving alternative to relays and contactors.
The ALPHA series is suited to applications in industrial machines and in automated building services.
Key enhancements in the ALPHA2 include a program capacity of 200 function blocks, an extra-large display, expansion options and a second communications port. The instruction set, includes math operations, PWM and SMS text messaging functions. All this opens up possibilities for analog and temperature control as well as remote operation.
## **The MELSEC FX family**
The MELSEC FX family includes a very comprehensive range of base and expansion modules, enabling you to configure a customised system tailored to your precise requirements.
Depending on your application and control needs you can choose between the small, attractively-priced, "stand-alone" MELSEC FX3S series, and the efficient FX3G, FX3GC, FX3GE, FX3U and FX3UC series.
With the exception of the FX3S all FX series can be expanded to adapt them to the changing needs of your installations and applications.
Network integration is also supported, making it possible for your FX controllers to communicate with other PLCs, controllers and HMIs.
The PLC systems can be configured as local stations in Mitsubishi Electric networks. In addition these flexible units can also be used as master or slave units on fieldbus’s like Profibus DP and CC-Link.
The MELSEC FX Family controllers also support CANopen, DeviceNet, Ethernet or J1939 (NMEA 2000).
**==> picture [83 x 58] intentionally omitted <==**
**----- Start of picture text -----**<br>
Decrease s<br>| poses S s<br>DC INPUT<br>ESC<br>OK<br>(A) (B) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br>AL2-24MR-D<br>POWER24V DC<br>+ -<br>MITSUBISHI<br>**----- End of picture text -----**<br>
**==> picture [106 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
iy —.<br>\ ; revit|<br>0 1 2 3 4 5 6 7<br>LOT<br>X16 X17 X20 X21 X22 X23 X24 X25 X26 X27<br>X11 Y12 X13 5Y14 Y15 Y16 Y17<br>INPUTANALOG V1+ I1+ V2+ I2+ VI-<br>100MSD/RDERROPEN<br>10BASE-T/100BASE-TX<br>OUTPUTANALOG V+ I+ VI-<br>0 1 2 3 4 5 6 7<br>20 21 22 23 24 25 26 27<br>10 11 12 13 14 15 16 17<br>10 11 12 13 14 15 16 17<br>**----- End of picture text -----**<br>
## **Expandability and power**
The MELSEC FX family is highly flexible, enabling fast and efficient configuration and programming for the application at hand.
It is the ideal choice, no matter whether you need to install a simple control application requiring 10 I/Os (FX3S) or a demanding, complex system with up to 384 I/O points (FX3U). The use of memory cassettes can expand the available programming space on some FX Family PLCs while generally providing a long term program storage option for all FX PLC users. In addition, memory cassettes can also allow programs to be switched at very short notice simply by replacing the cassette.
There are six series in the MELSEC FX family, each of which is designed for a different application profile:
## z **The FX3S series**
The MELSEC FX3S-series is the inexpensive entry to the MELSEC FX family and with its small dimensions it is also an excellent alternative to relay and contactor configurations.
## z **The FX3G series**
The FX3G is an introductory compact PLC and is designed for simple yet performance-critical applications. Incorporating innovative FX3 series technology the customer is presented with a suite of benefits.
## z **The FX3GE series**
The FX3GE series provides the advantages and expandability of the FX3G series and in addition a built-in Ethernet interface as well as two integrated analog inputs and one analog output.
## z **The FX3GC series**
The performance of the FX3GC is the same as that of the FX3G series. Due to its plug-in connectors for I/O signals it has even more compact dimensions.
## z **The FX3U/FX3UC series**
The FX3U series gives you the freedom of modular expandability, with a wide selection of expansion modules and special function modules.
The FX3U is the fastest PLC system available, with a cycle time of just 0.065 µs per logical instruction. This gives users a powerful CPU delivering modular PLC performance in a compact PLC design.
The performance of the FX3UC is the same as that of the FX3U series, but it has more compact dimensions. It is the ideal choice for applications where little space is available for the controller.
**==> picture [140 x 76] intentionally omitted <==**
**----- Start of picture text -----**<br>
7 ao 2<br>3 S<br>S s<br>FX3U/FX3UC<br>FX3S FX3G/FX3GC/FX3GE<br>No. of inputs/outputs Oo Cycle time (µs)<br>Program steps * Available with optional cassette<br>4,000<br>0.21<br>**----- End of picture text -----**<br>
4
System Description
## **Features**
The modular design of the MELSEC FX family makes it extremely flexible, enabling it to be used for a very broad range of applications. You can configure tailor-made systems by combining modules from a variety of different categories (see figure).
All modules are electrically isolated from their environment with optocouplers for maximum reliability.
## **Digital I/O modules**
For a variety of signal levels with relay or transistor switches
## **Communications modules**
Interface modules with RS232/ RS422/RS485 interfaces for the connection of peripherals and PLC-PLC links.
Network modules for Ethernet, Profibus DP, CC-Link, DeviceNet, CANopen, Modbus RTU/ASCII, J1939 as well as for the configuration of proprietary Mitsubishi Electric networks
## **Analog I/O modules**
## **Positioning modules**
High-speed counter modules with support for the connection of incremental rotary transducers and positioning modules for servo and stepping motor drives
For processing current/voltage signals and temperature registration with a direct connection option for Pt100 resistance thermometers and thermocouplers
## **Digital and special function modules – configuration**
The options for using digital and special function modules are dictated by the CPU used in the system.
When calculating the number of special function modules you can use in a system you must take both the number of digital modules and the maximum number of special function modules that can be used into account.
The table on the right provides a simplified guide to the number of modules you can use in each system type. More detailed information and the basic principles of system configuration can be found in the corresponding manuals.
**==> picture [337 x 185] intentionally omitted <==**
**----- Start of picture text -----**<br>
CPU type System restrictions<br>Stand-alone PLC with 10/14/20 or 30 I/Os<br>FX3S It is not possible to connect special function modules on the right side of the base unit. On the left side of the base unit<br>a communication adapter module and an analog adapter module of the FX3U series can be connected. Furthermore an<br>extension adapter can be installed directly in the base unit.<br>PLC with max. 256 I/Os<br>FX3G A maximum of 8 special function modules and digital extension modules with up to 128 I/Os can be connected to the<br>right side of the main unit. In addition, a maximum of 4 adapters from the FX3U series can be connected to the left side.<br>PLC with max. 256 I/Os<br>FX3GC At the left side of the base unit up to two communications adapters as well as maximal two analog I/O adapters of the<br>FX3U series can be connected. On the right side of the base unit up to 8 special function modules and digital extension<br>modules can be connected with up to 128 inputs and outputs.<br>PLC with max. 256 I/Os<br>FX3GE At the left side of the base unit one communications adapter and one analog I/O adapter of the FX3U series can be<br>connected. On the right side of the base unit up to 8 special function modules and digital extension modules can be<br>connected with up to 128 inputs and outputs.<br>PLC with max. 384 I/Os<br>FX3U To the left side of the main unit, a maximum of 10 adapters from the FX3U series can be connected. To the right side of<br>the main unit, up to 8 special function modules and digital extension modules with up to 256 I/Os can be connected.<br>SPS mit max. 384 Ein-/Ausgängen<br>FX3UC To the left side of the main unit, a maximum of 6 adapters from the FX3U series can be connected. To the right side of the<br>main unit, up to 4 special function modules and digital extension modules with up to 256 I/Os can be connected.<br>**----- End of picture text -----**<br>
5
System Description
## **What components are required for an FX PLC system?**
A basic FX PLC system can consist of a standalone base unit, with the functionality and I/O range increased by adding extension I/O and special function modules. The following section provides an overview of options available.
## **Base units**
The entire FX PLC range can be AC or DC powered with a mix of input and output styles. The PLCs can be programmed with the user friendly GX Works2 programming software, allowing programs to be transferred between different FX PLCs. All PLC base units include an integrated real time clock.
Base units are available with different I/O configurations from 10 to 128 points but can be expanded to 384 points depending upon the FX range selected.
## **Extension boards**
Except for the FX3GC and FX3UC series, extension adapter boards can be installed directly into the base unit and therefore do not require any additional installation space. For a small number of I/O (2 to 4) an extension adapter boards can be installed directly into the FX3S, FX3G, FX3GE or FX3U controller. Interface adapter boards can also provide the FX PLC with additional RS232, RS422, RS485 or USB interfaces. To connect adapter modules (e.g. Ethernet module) a communication adapter has to be installed (except FX3UC).
## **Extension I/O modules**
Unpowered and powered extension I/O modules can be added to the FX3G, FX3GC, FX3GE, FX3U and FX3UC PLCs.
## **Special function modules**
A wide variety of special function modules are available for the FX3G, FX3GC, FX3GE, FX3U and FX3UC PLCs. They cover networking functionality, analog control, pulse train outputs, data logging function and temperature inputs.
## **Memory extension and operator terminals**
Each FX family base unit (except FX3GC) can be equipped with a memory cassette. The programming unit interface enables the connection of programming tools like PC and hand held programming units as well as graphical operator terminals.
For expansion modules powered by the base unit, the power consumption has to be calculated as the 5 V DC bus can only support a limited number of expansion I/O (for further details please refer to next page – calculation of the power consumption).
**==> picture [510 x 113] intentionally omitted <==**
**==> picture [512 x 254] intentionally omitted <==**
**----- Start of picture text -----**<br>
Expansion possibilities ALPHA 2 FX3S FX3G FX3GC FX3GE FX3U FX3UC Reference page<br>Extensions for inside PLC Digital P — P — — P P 11<br>installation Analog P P P — P P P 11, 44<br>Extension modules Digital — — P P P P P 30<br>(installation outside Analog — P P P P P P 33<br>the PLC) Temperature P P P P P P P 11,34<br>Ethernet — P P P P P P 40<br>CC-Link — — P P P P P 40<br>CANopen — — P P P P P 43<br>Profibus DP — — P P P P P 41<br>Network modules<br>DeviceNet — — P P P P P 43<br>Modbus RTU/ASCII — — P P P P P 44<br>SSCNET — — — — — P P 38<br>J1939 — — P P P P P 44<br>RS232 P P P — P P — 46<br>RS422 — — P — P P — 46<br>Communications boards<br>RS485 — P P — P P — 46<br>USB — — — — — P — 48<br>RS232 — — P P P P P 43<br>Communications modules<br>RS485 — — P P P P P 43<br>Dedicated function High speed counter — — — — — P P 36<br>modules Positioning — — — — — P P 38<br>Memory cassettes P P P — P P P 12, 49<br>External display — — P — P P — 54<br>**----- End of picture text -----**<br>
6
System Description
## **Calculation of the power consumption**
The power consumption figures on the 5 V DC bus for the special function modules are shown in the specifications tables on the following pages.
The maximum permissible currents on the 5 V DC and 24 V DC bus are shown in the table below.
**==> picture [163 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
Max. current<br>Modules<br>5 V bus 24 V bus<br>FX3G-14/24Mm-ES(ESS) — 400 mA<br>FX3G-40/60Mm-ES(ESS) — 400 mA<br>FX3U-16/32Mm-ES(ESS) 500 mA 400 mA<br>FX3U-48–128Mm-ES(ESS) 500 mA 600 mA<br>FX3UC-16MT/D(DSS) 600 mA —<br>FX3UC-32MT/D(DSS) 560 mA —<br>FX3UC-64MT/D(DSS) 480 mA —<br>FX3UC-96MT/D(DSS) 400 mA —<br>**----- End of picture text -----**<br>
The residual currents for the 24 V DC service voltage at different input/output configurations are shown in the tables on the right. A maximum of 256 I/Os are possible for FX3U/ FX3UC (128 I/Os for FX3G/FX3GC/FX3GE).
Max. residual current values (in mA) for FX3U-16Mm/Emm through FX3U-32Mm/Emm for the permissible configuration
|**Number of**<br>**additional**<br>**outputs**|**40**|25|25|25|25|25|25|25|25|25|
|---|---|---|---|---|---|---|---|---|---|---|
||**32**|100|50|0|||||||
||**24**|175|125|75|25||||||
||**16**|250|200|150|100|50|0||||
||**8**|325|275|225|175|125|75|25|||
||**0**|400|350|300|250|200|150|100|50|0|
|||**0**|**8**|**16**|**24**|**32**|**40**|**48**|**56**|**64**|
|||**Number of additional inputs**|||||||||
Max. residual current values (in mA) for FX3U-48Mm/Emm through FX3U-128Mm/Emm for the permissible configuration
**==> picture [339 x 115] intentionally omitted <==**
**----- Start of picture text -----**<br>
64 0<br>56 75 25<br>48 150 100 50 0<br>40 225 175 125 75 25<br>Number of<br>additional 32 300 250 200 150 100 50 0<br>outputs 24 375 325 275 225 175 125 75 25<br>16 450 400 350 300 250 200 150 100 50 0<br>8 525 475 425 375 325 275 225 175 125 75 25<br>0 600 550 500 450 400 350 300 250 200 150 100 50 0<br>0 8 16 24 32 40 48 56 64 72 80 88 96<br>Number of additional inputs<br>**----- End of picture text -----**<br>
## **Sample calculations**
The tables below and on the right show different examples for sample power calculation for a PLC system.
The current values for the special function modules can be found in the specifications on the following pages. Comparison with the current value tables show that the calculated figures for the 5 V bus lie within the allowable ranges.
**==> picture [337 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
24 V DC calculation 5 V DC calculation<br>Module No.<br>Current/module Calculation Current/module Total current<br>FX3U-80MR/ES 1 600 mA +600 mA +500 mA +500 mA<br>FX3U-4AD 2 90 mA -180 mA 110 mA -220 mA<br>FX3U-4DA 2 160 mA -320 mA 120 mA -240 mA<br>FX3U-ENET 1 240 mA -240 mA — —<br>-140 mA !!! 500–460 mA<br>Result: 40 mA (OK !)<br>**----- End of picture text -----**<br>
An external 24 V power supply has to be added in the example above.
In the example below all units can be supplied sufficiently with the internal 24 V power supply.
**==> picture [512 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
Number of I/Os 24 V DC calculation 5 V DC calculation<br>Module No.<br>X Y X/Y Total [1] Total current [2] Current/module Total current<br>FX3U-48MR/ES 1 24 24 — 500 mA +500 mA<br>FX2N-16EYR-ES/UL 1 — 16 — X = 8 — 0 mA<br>Y = 24 +325 mA<br>FX2N-8EX-ES/UL 1 8 — — R — 0 mA<br>FX2N-8EYR-ES/UL 1 — 8 — — 0 mA<br>FX3U-4AD-PT-ADP 1 — — — -50 mA 30 mA -15 mA<br>+275 mA (OK!) +485 mA (OK!)<br>FX2N-32ER-ES/UL 1 16 16 — +150 mA residual 690 mA +690 mA<br>FX2N-16EX-ES/UL 1 16 — — X = 16 Y = 0 current for extension unit FX2N-32ER-ES/UL — 0 mA<br>FX2N-10PG 1 — — 8 R 0 mA 120 mA -120 mA<br>FX2N-32CCL 1 — — 8 -50 mA 130 mA -130 mA<br>Result : 64 + 64 +16= 144 ! (< 256) OK! +100 mA (OK!) +440 mA (OK!)<br>**----- End of picture text -----**<br>
1 Total no. of I/Os which are connected to a base unit to calculate the max. residual current values (see tables)
2 see tables above (max. residual current values)
7
ALPHA System Outline
## ~~**The ALPHA 2 series**~~
~~**1**~~
**==> picture [511 x 660] intentionally omitted <==**
**----- Start of picture text -----**<br>
The analog inputs (0–10 V, 9 bits resolution)<br>Up to 15 inputs can be used as digital can be used very easily due to the integrated<br>inputs and up to 8 for analog inputs gain function and a Schmitt-trigger.<br>(controllers with 24 V DC supply). The communication with a com-<br>puter and with external peripherals<br>is supported by the two integrated<br>serial interfaces .<br>Integrated calender/real-time function a.<br>with up to 1200 switch ON or OFF ————<br>commands in one program =<br>Direct programming via 8 function<br>keys on the front control panel<br>} aa without any additional program-<br>! eeeSS ming device<br>el<br>*<br>The units can be expanded<br>© to additional inputs/outputs<br>with extension modules to<br>be mounted directly into the<br>controller<br>— ———— CC<br>Flexible mounting through integrated<br>DIN rail adapter and screw fixing<br>SS en<br>Large LC display for program- The program is stored in a maintenance-free<br>ming, entering, and editing plain EEPROM with a memory capacity of 5000 bytes.<br>text, values and bar graphs A backup battery is not required.<br>Password protection<br>can be activated.<br>Description of the unit components<br>Power supply terminals<br>Mounting hole Se Terminals for<br>digital/analog inputs<br>QShccscccsssoonooncel<br>ee Connector for PC, GSM,<br>Adapter for DIN rail mounting modem and other<br>automation components<br>Slot for EEPROM cassette<br>or connector for i fe == eee" SS a Operating keys (8 pcs.)<br>programming cable<br>KI at) [L@L@_O N<br>Housing cover (place holder) for<br>the extension modules<br>Protective cover<br>= ee<br>LCD display Ay)<br>(4 lines x 12 characters)<br>Connection for extensions<br>Terminals for digital outputs<br>(A) (B) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br>DC INPUT<br>AL2-24MR-D<br>POWER<br>24V DC<br>POWER<br>24V DC<br>ESC<br>OK<br>+ -<br>+ -<br>(A) (B) 1 2 3 4 5 6 7 DC INPUT8 9 10 11 12 13 14 15<br>AL2-24MR-D<br>ESC<br>OK<br>MITSUBISHI<br>MITSUBISHI<br>**----- End of picture text -----**<br>
8
Alpha Base Units
~~**Specifications ALPHA 2**~~
~~**1**~~
## **ALPHA 2 base units**
**==> picture [155 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
E e<br>i —SS©<br>® ><br>© © ZZ<br>6 @ ©_O ——<br>— =~ a<br>e.g. AL2-24Mm-m<br>AL2-24MR-D<br>+ -<br>(A) (B) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15<br>ESC<br>OK<br>POWER24V DC<br>DC INPUT<br>MITSUBISHI<br>**----- End of picture text -----**<br>
The ALPHA 2 controllers offer simple reliable control for a range of automation applications including lighting, air conditioning, security systems, and temperature and water control.
- z Transistor and relay output options
- z Analog input/output
- z High speed counters up to 1 kHz
- z GSM function for communication with mobile phones
- z Language support for 8 different languages
- z Display unit for messages and function block data
## **Base units with 10–24 I/Os**
|**Specifications**<br>**AL2-10MR-A**<br>**AL2-10MR-D**<br>**AL2-14MR-A**<br>**AL2-14MR-D**<br>**AL2-24MR-A**<br>**AL2-24MR-D**<br>~~ee~~|**Specifications**<br>**AL2-10MR-A**<br>**AL2-10MR-D**<br>**AL2-14MR-A**<br>**AL2-14MR-D**<br>**AL2-24MR-A**<br>**AL2-24MR-D**<br>~~ee~~|
|---|---|
|**Electrical specifications**||
|Integrated inputs/outputs|10<br>10<br>14<br>14<br>24<br>24|
|Power supply|100–240 V AC<br>24 V DC<br>100–240 V AC<br>24 V DC<br>100–240 V AC<br>24 V DC|
|Digital inputs|6<br>6<br>8<br>8<br>15<br>15|
|Analog inputs|—<br>6<br>—<br>8<br>—<br>8|
|Channels|—<br>6<br>—<br>8<br>—<br>8|
|Integrated outputs|4<br>4<br>6<br>6<br>9<br>9|
|||
|Max.power consumption<br>W|4.9<br>4.0<br>5.5<br>7.5<br>7.0<br>9.0|
|Typ. power<br>consumption<br>all I/Os<br>ON/OFF<br>W|3.5/1.85 240 V AC<br>3.0/1.55 120 V AC<br>2.5/0.75<br>4.5/2.0 240 V AC<br>3.5/1.5 120 V AC<br>4.0/1.0<br>5.5/2.5 240 V AC<br>4.5/2.0 120 V AC<br>5.0/1.0|
|Weight<br>kg|0.2<br>0.2<br>0.3<br>0.3<br>0.35<br>0.3|
|Dimensions(WxHxD)<br>mm|71.2x90x55<br>71.2x90x55<br>124.6x90x52<br>124.6x90x52<br>124.6x90x52<br>124.6x90x52|
|||
|**Order information**<br>Art. no.|215070<br>215071<br>215072<br>215073<br>215074<br>215075|
|||
|**Accessories**|Power supplies with DIN-rail or wall mounting possibility for powering the 24 V DC modules (refer to the power supply chapter in this catalogue);<br>IP40 mounting frame AL2-FRAME-14/24-IP40, art. no.: 231366; IP54 mounting frame AL2-FRAME-14/24-IP54, art. no.: 231368 for AL2-14/24<br>IP40 mountingframe AL2-FRAME-10-IP40,art. no.: 231365;IP54 mountingframe AL2-FRAME-10-IP54,art. no.: 231367 for AL2-10|
9
General Specifications
~~**1**~~
## **Environmental specifications**
**==> picture [512 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Alpha 2 series<br>Ambient temperature Display: -10–55 °C, Hardware: -25–55 °C (storage temperature: -30–+70 °C)<br>Protection rating IP20<br>Noise immunity 1000 Vpp with noise generator; 1 µs at 30–100 Hz, tested by noise simulator<br>Dielectric withstand voltage 3750 V AC, >1 min. according to EN 60730<br>Allowable relative humidity 35–85 % (no condensation)<br>Shock resistance Acc. to IEC 68-2-27: 147 m/s [2] acceleration, 11 ms 3x3 directions<br>direct mounting Acc. to IEC-2-6: 19.6 m/s [2] acceleration, 80 min. in each direction<br>Vibration resistance<br>DIN rail mounting Acc. to IEC-2-6: 9.8 m/s [2] acceleration, 80 min. in each direction<br>Insulation resistance 500 V DC, 7 MΩ acc. to EN60730-1<br>Ambient conditions No corrosive gases, no dust<br>Certifications Please refer to pages 66–67 in this catalogue<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 262] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC powered modules AC powered modules<br>Power supply specifications (AL2- m MR-D) (AL2- m MR-A)<br>Power supply 24 V DC 100–240 V AC (50/60 Hz)<br>Inrush current at ON ≤ 7.0 A (at 24 V DC) ≤ 6.5 A (at 240 V AC)<br>Allowable momentary power failure time 5 ms 10 ms<br>Digital Inputs<br>24 V DC 100–240 V AC<br>Input voltage (+20 %/-15 %) (+10 %/-15 %), 50/60 Hz<br>The input current changes<br>depending on Source or Sink.<br>For Sink: I01–I08<br>(AL2-10/14/24MR-D) 0.13 mA/120 V AC*<br>= 5.5 mA, 24 V DC 0.25 mA/240 V AC*<br>Input current For Source: I09–I15<br>(AL2-10/14MR-D) 0.15 mA/120 V AC*<br>= 6.0 mA, 24 V DC 0.29 mA/240 V AC*<br>(AL2-24MR-D)<br>= 5.5 mA, 24 V DC<br>Response time OFF → ON ms 10–20 35–85 ms, 120 V AC 25–55 ms, 240 V AC<br>ON → OFF ms 10–20 35–85 ms, 120 V AC 50–130 ms, 240 V AC<br>Analog Inputs<br>Analog input range 0–500 —<br>Resolution 9 bit, (10 V/500) —<br>Conversion speed ms 8 —<br>Voltage 0–10 V DC —<br>Impedance kΩ142 ±5 % —<br>Accuracy ±5 % (0.5 V DC) —<br>**----- End of picture text -----**<br>
**==> picture [250 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output specifications All modules<br>Type Relay<br>Switching voltage (max.) V 250 V AC, 30 V DC<br>10M, 14M: 8 A/point<br>Rated current 24M (001-004): 8 A/point<br>24M (005-009): 2 A/point<br>Max. switching load - inductive load 14M, 24M: 249 VA, 250 V AC/373 VA, 250 V AC 24M: 93 VA, 125 V AC/93 VA, 250 V AC<br>Minimum load 10 mA, 5 V DC<br>Response time ms ≤ 10<br>**----- End of picture text -----**<br>
* Current leakage from the sensors connected to the inputs might provide enough current to turn the controller ON. Do not use two wire sensors.
10
Extension Modules
~~**1**~~
## **Digital extension modules**
**==> picture [286 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
><br>There are 4 different extension modules avail-<br>hE EEY N el able for the ALPHA 2, which allow the controller<br>psb085 to be extended through additional inputs or<br>outputs. The modules are inserted directly into<br>|<br>the ALPHA 2 and therefore do not take up any<br>n additional space.<br>RR<br>EO3 EO4<br>OUTPUTRELAY<br>4EYR<br>MITSUBISHI<br>EO1 EO2<br>**----- End of picture text -----**<br>
The AL2-4EX has the additional feature that 2 inputs may be used as high-speed counters with a counting frequency of 1 kHz.
All modules feature photocoupler insulation for all I/Os.
|**Inputs**|**Inputs**|
|---|---|
|Integrated inputs|4<br>4<br>—<br>—|
|Input voltage|220–240 V AC<br>24 V DC(+20 %,-15 %)<br>—<br>—|
|Input current|7.5 mA at 240 V AC (50 Hz),<br>9.0 mA at 240 V AC(60 Hz)<br>5.4 mA ±1 mA at 24 V DC<br>—<br>—|
|**Outputs**||
|Integrated outputs|—<br>—<br>4<br>4|
|Output type|—<br>—<br>Relay<br>Transistor|
|Switched voltage(max.)<br>V|—<br>—<br>250 V AC,30 V DC<br>5–24 V DC|
|Rated current<br>A|—<br>—<br>2 Aper output<br>1 Aper output|
|**Electrical specifications**||
|Power Supply<br>AC range<br>(+10 %,-15 %)|220–240 V AC<br>24 V DC<br>100–240 V AC<br>24 V DC|
|**Mechanical specifications**||
|Weight<br>kg|0.05<br>0.05<br>0.05<br>0.05|
|Dimensions (WxHxD)<br>mm|53.1x90x24.5<br>53.1x90x24.5<br>53.1x90x24.5<br>53.1x90x24.5|
Note: I1 and I2 of the AL2-4EX can be used as high-speed counter inputs. In each case the response time for the high-speed counter inputs will be 0.5 ms or less. The AL2-4EX-A2, AL2-4EX, AL2-4EYR and AL2-4EYT modules can not be used with the AL2-10MR series.
## **Analog extension modules**
**==> picture [452 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
The analog extension modules significantly z<br>increase the range of applications for the<br>ALPHA 2. With these modules it is possible to<br>output voltage or current signals or to measure<br>temperatures. z<br>Three different analog extension modules are<br>available: analog signals (0–10 V).<br>z<br>a ,<br>ings into analog signals (0–10 V).<br>V2+ I2+ VI2-<br>CH1 CH2<br>CH1 CH2<br>+ -<br>+ -<br>AL2-2PT-ADPPT100 -50~200°C<br>K-type Thermocouple -50~450°CAL2-2TC-ADP<br>POWER24V DC ANALOGOUTPUT<br>ANALOGOUTPUT 2DA<br>MITSUBISHI<br>MITSUBISHI<br>POWER<br>POWER<br>V1+ V1- V2+ V2-<br>POWER24V DC OUTPUT 0~10V<br>V1+ V1- V2+ V2-<br>POWER24V DC OUTPUT 0~10V<br>200°C -50°CCH1 Line 200°C CH2-50°C Line<br>450°C -50°CCH1 Line 450°C CH2-50°C Line CH1 CH2<br>L1+ L1- I1- L2+ L2- I2-<br>CH1 CH2<br>L1+ L1- SLD L2+ L2- SLD<br>MITSUBISHI<br>+ - V1+ I1+ VI1-<br>**----- End of picture text -----**<br>
- z The AL2-2DA offers two additional analog outputs for the ALPHA 2 and converts a digital input value into a voltage or a current. This module is inserted directly into the ALPHA 2.
- z The AL2-2PT-ADP connects an external PT100 sensor to convert temperature readings into analog signals (0–10 V).
- z The AL2-2TC-ADP connects thermocouple sensors (K type) to convert temperature read-
~~|~~ **Analog extension modules specifications AL2-2DA AL2-2PT-ADP AL2-2TC-ADP**
|**Analog inputs**<br>~~|~~|**Analog inputs**<br>~~|~~|
|---|---|
|Integrated inputs|—<br>2<br>2|
|Connectable temperature sensors|—<br>Pt100 sensor<br>Temp. coefficient 3.850ppm/°C(IEC 751)<br>Thermocouple (K type), isolated type<br>(IEC 584-1 1977,IEC 584-2 1982)|
|Compensated range|—<br>-50–+200 °C<br>-50–+450 °C|
|**Analog outputs**||
|Integrated outputs|2<br>—<br>—|
|Analog output range<br>voltage<br>current|0–10 V DC(5 kΩ–1 MΩ)<br>—<br>—|
||4–20 mA(max. 500 Ω)<br>—<br>—|
|**Electrical specifications**||
|Number of channels|2<br>2<br>2|
|Power Supply|24 V DC(-15–+10 %),70 mA<br>24 V DC(-15–+20 %),1 W<br>24 V DC(-15–+20 %),1 W|
|**Mechanical specifications**||
|Weight<br>kg|0.05<br>0.07<br>0.07|
|Dimensions (WxHxD)<br>mm|53.1x90x24.5<br>35.5x90x32.5<br>35.5x90x32.5|
Note: the AL2-2DA module can not be used with the AL2-10MR series
11
Extension Modules and Accessories
**==> picture [149 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
o a aa<br>1<br>a _—<br>ASI+ASI-ASI+ASI-<br>Alpha Series<br>**----- End of picture text -----**<br>
## **AS-Interface module AL2-ASI-BD**
The Actuator Sensor Interface module AL2-ASI-BD in combination with an ALPHA 2 controller facilitates the data communications via an AS-Interface system. The AL2-ASI-BD is attached to an ALPHA 2 series module and forms a slave unit. Up to 4 inputs and 4 outputs can be exchanged with the AS-Interface master.
The addresses of the slave devices in the ASInterface are assigned either automatically via the master in the network or via a programming device (software).
The maximum communication distance is 100 m without a repeater. If 2 repeaters are used, the distance is extended to up to 300 m.
For the AS-Interface a separate power supply is required. The communication signal is superimposed on the power supply of the AS-Interface bus.
Note: The AL2-ASI-BD cannot be used with the AL2-10MR series.
|**Specifications**|**AL2-ASI-BD**|
|---|---|
|Module type|Slave module|
|Number of I/Opoints|4 inputs,4 outputs|
|Externalpower supply|30.5 V DC(AS-Interfacepower supply)|
|External current consumption<br>mA|Max. 40|
|Communicationsprotocol|AS-Interface standard|
|Weight<br>kg|0.05|
|Dimensions (WxHxD)<br>mm|53.1x90x24.5|
|**Order information**<br>Art. no.|142525|
Note: The AL2-ASI-BD cannot be used with the AL2-10MR series.
## **Memory cassette AL2-EEPROM-2 memory media**
**==> picture [41 x 59] intentionally omitted <==**
**----- Start of picture text -----**<br>
i<br>AL2-EEPROM MADE IN JAPAN<br>**----- End of picture text -----**<br>
Nel tS AL-232CAB
**==> picture [147 x 48] intentionally omitted <==**
**----- Start of picture text -----**<br>
ESN<br>AL2-GSM-CAB<br>AL2-GSM-CABLOT .24MITSUBISHI ELECTRIC<br>**----- End of picture text -----**<br>
After removing the memory cassette, the former program in the internal memory becomes active again.
With the AL2-EEPROM-2 memory cassettes, a new program can be transferred to the ALPHA 2 controller’s internal system memory from the cassette, or the program of the internal system memory can be saved to the cassette.
The memory cassette AL2-EEPROM-2 is not a memory expansion device, but a medium for data exchange.
If the memory cassette is used, a certain program can be run temporarily by simply plugging the external memory module onto the ALPHA 2.
|**Specifications**|**AL2-EEPROM-2**|
|---|---|
|Memorytype|EEPROM|
|Application|ALPHA 2|
|Memorycapacity|5,000 bytes|
|Function blocks|Max. 200|
|Dimensions(WxHxD) <br>mm|10x45x25|
|||
|**Order information**<br>Art. no.|142526|
## **Interface Cable AL-232CAB**
## **GSM Cable AL2-GSM-CAB**
The AL-232CAB is an RS232C interface cable. It connects the ALPHA 2 controller to a personal computer running the programming software for the ALPHA 2 controller.
The GSM AL2-GSM-CAB is an RS232C interface cable and it is used to connect the ALPHA 2 controller to a normal or GSM modem, a personal computer or other serial devices. It can transfer SMS data to a GSM modem for onward transmission to mobile telephones or e-mail addresses. It also permits remote monitoring and remote
The cable ensures a galvanic isolation between the ALPHA 2 controller and the personal computer. The cable AL-232CAB can not be used for any other connection. maintenance.
**Specifications AL-232CAB AL2-GSM-CAB** Connector 9-pin D-SUB female connector 9-pin D-SUB male connector ~~a~~ Application ALPHA 2 <-> PC ALPHA 2 <-> PC, modem Length m 2.5 1.5 **Order information** Art. no. 87674 142528
Note: The above cables cannot be used with the AL2-10MR series.
12
Base Units FX3S Series
~~**2**~~
## **The MELSEC FX3S series**
**==> picture [494 x 336] intentionally omitted <==**
**----- Start of picture text -----**<br>
The internal service power supply<br>unit for 24 V DC has a capacity of<br>High-speed inputs for fast counting 400 mA.<br>tasks with counting frequencies of up<br>Two integrated analog inputs<br>to 60 kHz and interrupt processing<br>(FX3S-30MT/ESS-2AD and<br>capabilities<br>FX3S-30MR/ES-2AD) only)<br>Integrated real-time clock<br>with year, month, day and<br>time<br>q<br>Flexible installation with the Sees All units feature two analog<br>potentiometers for setpoint value<br>integrated DIN rail adapter and screw<br>entry and an integrated RUN/STOP<br>fastening holes for mounting on flat<br>surfaces h ' | a, switch.<br>MITSUBISH| fla<br>Your PLC programs are stored in a mainte-<br>nance-free EEPROM user memory<br>capacity of 4,000 program steps, so there<br>Integration of interface, extension,<br>is no need for a backup battery to protect<br>and functions adapters for direct<br>against power failures.<br>installation in the base unit ay ig |<br>IN RIELSE@ FXes Ft<br>Integrated serial RS422 interface<br>for direct communication with<br>computers<br>Password access protection<br>facility for effective protection of<br>your intellectual property.. Square pulse output<br>(this applies only to transistor units.)<br>Two integrated high speed pulse<br>outputs for frequencies up to 100 kHz for<br>outputting pulse signals and controlling<br>stepping motors<br>**----- End of picture text -----**<br>
**==> picture [124 x 41] intentionally omitted <==**
**----- Start of picture text -----**<br>
Your PLC programs are stored in a mainte-<br>nance-free EEPROM user memory with a<br>capacity of 4,000 program steps, so there<br>is no need for a backup battery to protect<br>against power failures.<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [472 x 278] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protective cover<br>: 6000007 Terminal cover<br>Terminals for digital inputs<br>Connection of the power supply<br>2 analog potentiometers<br>Slot for extension adapter M il fs RUN/STOP switch<br>or memory cassette —_—§_h ll i | on<br>Input operating status indication Io fee<br>LEDs for indicating the operating status USB interface<br>RS422 interface<br>Output operating status indication<br>Cover for interface, potentiometer and<br>RUN/STOP switch<br>Terminals for digital outputs<br>Cover for extension slot<br>BM ESE Ps |_|<br>(00000+} Terminal cover<br>Protective cover<br>**----- End of picture text -----**<br>
13
Base Units FX3S Series
~~**2**~~
## ~~**Base units**~~
## ~~þ~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Base units FX3S**
The FX3S series base units are available with 10 to 30 input/output points.
It is possible to choose between relay and transistor output type.
- z Integrated power supply (AC or DC powered)
- z Maintenance-free EEPROM memory
- z Ample memory capacity (4000 steps) and device ranges
- z High-speed operations
- z Incorporated positioning control
- z Integrated real-time clock
- z FX3S-30MT/ESS-2AD and FX3S-30MR/ES-2AD with two integrated analog inputs (0-10 V DC)
- z System upgrades by exchangeable interface and I/O adapter boards for direct fitting into the base unit
- z LEDs for indicating the input and output status
- z Standard programming unit interface
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3)-compatible programming software, HMIs and hand-held programming units
## **Base units with 10–14 I/Os**
|**Specifications**<br>CO|**FX3S-10**<br>**MR-ES**|**FX3S-10**<br>**MR-DS**|**FX3S-10**<br>**MT-ESS**|**FX3S-10**<br>**MT/DSS**|**FX3S-14**<br>**MR-ES**|**FX3S-14**<br>**MR-DS**|**FX3S-14**<br>**MT-ESS**|**FX3S-14**<br>**MT/DSS**|
|---|---|---|---|---|---|---|---|---|
|Max. number inputs/outputs|10|10|10|10|14|14|14|14|
|Power supply|100–240 V AC|24 V DC|100–240 V AC|24 V DC|100–240 V AC|24 V DC|100–240 V AC|24 V DC|
|Integrated inputs|6|6|6|6|8|8|8|8|
|Integrated outputs|4|4|4|4|6|6|6|6|
|Output type|Relay|Relay|Transistor<br>(source)|Transistor<br>(source)|Relay|Relay|Transistor<br>(source)|Transistor<br>(source)|
||||||||||
|Power consumption<br>W|19|6|19|6|19|6,5|19|6,5|
|Weight<br>kg|0.30|0,30|0.30|0,30|0.30|0,30|0.30|0,30|
|Dimensions (WxHxD)<br>mm|90x60x75|90x60x75|90x60x75|90x60x75|90x60x75|90x60x75|90x60x75|90x60x75|
||||||||||
|**Order information**<br>Art. no. 267110|Art. no. 267110|271687|267112|271695|267113|271688|267125|271696|
## **Base units with 20–30 I/Os**
|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|**Specifications**<br>**FX3S-20**<br>**MR-ES**<br>**FX3S-20**<br>**MR-DS**<br>**FX3S-20**<br>**MT-ESS**<br>**FX3S-20**<br>**MT/DSS**<br>**FX3S-30**<br>**MR-ES**<br>**FX3S-30**<br>**MR-DS**<br>**FX3S-30**<br>**MR-ES-2AD**<br>**FX3S-30**<br>**MT-ESS**<br>**FX3S-30**<br>**MT-ESS-2AD**<br>**FX3S-30**<br>**MT/DSS**<br>C~~o~~|
|---|---|---|---|---|---|---|---|---|---|---|
|Max. number inputs/outputs|20|20|20|20|30|30|30|30|30|30|
|Power supply|100–240 V AC|24 V DC|100–240 V AC|24 V DC|100–240 V AC|24 V DC|100–240 V AC|100–240 V AC|100–240 V AC|24 V DC|
|Integrated inputs|12|12|12|12|16|16|16|16|16|16|
|Integrated outputs|8|8|8|8|14|14|14|14|14|14|
|Output type|Relay|Relay|Transistor<br>(source)|Transistor<br>(source)|Relay|Relais|Relais|Transistor<br>(source)|Transistor<br>(source)|Transistor<br>(source)|
||||||||||||
|Power consumption|W 20|7|20|7|21|8,5|21|21|21|8,5|
|Weight|kg 0.40|0,40|0.40|0,40|0.45|0,45|0,45|0.45|0,45|0,45|
|Dimensions (WxHxD)|mm 90x75x75|90x75x75|90x75x75|90x75x75|90x100x75|90x100x75|90x100x75|90x100x75|90x100x75|90x75x75|
||||||||||||
|**Order information**<br>Art. no. 267126||271689|267128|271697|267129|271690|271654|267131|271686|271698|
14
Base Units FX3S Series
~~**2**~~
## ~~�~~ ~~**[Specifications]**~~
## ~~þ~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Environmental specifications**
**==> picture [512 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Data<br>Ambient temperature 0–55 °C (storage temperature: -25–+75 °C)<br>Noise durability 1,000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage 1,500 V AC, 1 min<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC 68-2-27: 15 g (147m/s2) (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC 68-2-6: 1 g (Resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5G for DIN rail mounting<br>Insulation resistance 5 MΩ at 500 V DC<br>Ground Class D: Grounding resistance 100 Ω or less<br>Fuse rating 250 V 1.0 A<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 66–67<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply specifications AC powered modules (FX-3S- m M m /E m )<br>Power supply 100–240 V AC (+10 %/-15 %), 50/60 Hz<br>Inrush current at ON 30 A/<5 ms (at 100 V AC);<br>50 A/<5 ms (at 200 V AC)<br>Allowable momentary power 10 ms<br>failure time<br>Primary power supply —<br>External power supply 400 mA<br>(24 V DC)<br>**----- End of picture text -----**<br>
**==> picture [250 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
Relay- Transistor-<br>Output specifications Module Module<br>Switching voltage (max.) V <240 V AC, <30 V DC 5–30 V DC<br>Max. output - per output A 2 0.5<br>current - per group [b] A 8 0.8<br>Max. switching - inductive load 80 VA 12 W<br>current<br>Response time ms 10 <0.2 (<5 µs for Y0,Y1)<br>3,000,000 at 20 VA; 1,000,000 at 35 VA;<br>Life of contacts (switching times) [a]<br>200,000 at 80 VA<br>**----- End of picture text -----**<br>
a Not guaranteed by Mitsubishi Electric
b The limitation applies only per reference terminal for each group with 4 outputs. Please observe the terminal assignments for the group identification
## **Programming specifications**
**==> picture [251 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3S<br>Program data<br>I/O points (addresses) Max. 16 inputs, max 14 outputs (not expandable)<br>4000 steps EEPROM (internal),<br>Program memory exchangeable EEPROM memory cassette<br>Cycle period 0.21 µs /logical instruction<br>Number of instructions 27 sequence instructions, 2 step ladder instructions, 116 applied<br>instructions<br>Programming language Step ladder, instruction list, SFC<br>Program execution Cyclical execution, refresh mode processing<br>Program protection Via password<br>**----- End of picture text -----**<br>
**==> picture [250 x 209] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3S<br>Operands<br>Internal relays 1,536<br>Special relays 512<br>Step ladder 256<br>Timer 138<br>Ext. preset value via potentiometer 2<br>Counter 67<br>6 single phase inputs (max. 60 kHz),<br>High-speed counter 3 double phase inputs (max. 30 kHz)<br>Real-time clock Year, month, day, hour, minute, second, weekday<br>Data register 3,000<br>File register 2,000<br>Index register 16<br>Special register 512 (D8000–D8511)<br>Pointer 2,048<br>Nestings 8<br>Interrupt inputs 6<br>16 bits: K: -32768–+32767, hex: 0–FFFF<br>Constants 32 bits: K: 2147483648–+2147483647,<br>hex: 0–FFFF FFFF<br>**----- End of picture text -----**<br>
15
Base Units FX3G Series
~~**2**~~
## **The MELSEC FX3G series**
## **Integrated high-speed counter inputs**
for processing fast input signals. For example, you can configure two 60 kHz counters and four 10 kHz counters. **Interrupt processing** is also handled via the inputs.
Add-in function boards can be installed in the PLC to provide a **second RS485/RS422/ RS232 communications interface** for programming or network configurations. Analog function boards for input and output and a function board with 8 analog potentiometers are also available as add-in.
RAM/EEPROM memory for up to **32,000 PLC program steps** gives you plenty of reserve, even for big, complex applications.
The base units can be expanded to provide configurations with up to 256 inputs and outputs with modular and **compact extension units** (128 directly and 256 in common by using remote I/ Os via a network).
**==> picture [70 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Integrated real-time<br>clock with year, month,<br>day and time<br>**----- End of picture text -----**<br>
An **integrated RUN/STOP switch** is available.
Connection possibility for special function adapter modules
**Two integrated serial interfaces** for direct communication with computers.
Two **integrated pulse outputs** for frequencies from 2 to 100,000 Hz for controlling stepping motors and outputting **pulse-width modulated signals.**
## **Description of the unit components**
**==> picture [108 x 202] intentionally omitted <==**
**----- Start of picture text -----**<br>
Memory cassette, display module,<br>and expansion board connector<br>2 analog potentiometers<br>RUN/STOP switch<br>Option battery holder<br>Programming port: RS422<br>Programming port: USB<br>Flip cover for programming port,<br>potentiometer and Run/Stop switch<br>Cover for the left extension slot<br>**----- End of picture text -----**<br>
**==> picture [109 x 215] intentionally omitted <==**
**----- Start of picture text -----**<br>
Terminal cover<br>Terminal protector<br>Input terminals<br>Input indicator LEDs<br>Operation status indicator LEDs<br>Expansion bus connector cover<br>Output indicator LEDs<br>Output terminals<br>Terminal protector<br>Terminal cover<br>Cover of the right extension slot and<br>the optional battery<br>**----- End of picture text -----**<br>
16
Base Units FX3G Series
## ~~**Base units**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Base units FX3G**
The FX3G series base units are available with 14 to 60 input/output points.
It is possible to choose between relay and transistor output types.
- z Integrated USB interface for communication between PLCs and PC
- z Integrated serial interface for communication between PCs and HMI
- z LEDs for indicating the input and output status
- z Detachable terminal blocks for all units
- z Slot for memory cassettes
- z Integrated real-time clock
- z Integrated positioning control
- z Exchangeable interface and extension adapters for direct mounting into a base unit
- z Expandable with digital I/O modules, special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
~~**2**~~
## **Base units with 14–24 I/Os**
|Max. number inputs/outputs|14<br>14<br>14<br>14<br>24<br>24<br>24<br>24|
|---|---|
|Power supply|100–240 V AC<br>100–240 V AC<br>24 V DC<br>24 V DC<br>100–240 V AC<br>100–240 V AC<br>24 V DC<br>24 V DC|
|Integrated inputs|8<br>8<br>8<br>8<br>14<br>14<br>14<br>14|
|Integrated outputs|6<br>6<br>6<br>6<br>10<br>10<br>10<br>10|
|Output type<br>Power consumption|Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>W 31<br>31<br>19<br>19<br>32<br>32<br>21<br>21|
|Weight|kg 0.50<br>0.50<br>0.50<br>0.50<br>0.55<br>0.55<br>0.55<br>0.55|
|Dimensions (WxHxD)|mm 90x90x86<br>90x90x86<br>90x90x86<br>90x90x86<br>90x90x86<br>90x90x86<br>90x90x86<br>90x90x86|
## **Base units with 40–60 I/Os**
|Max. number inputs/outputs|40<br>40<br>40<br>40<br>60<br>60<br>60<br>60|
|---|---|
|Power supply|100–240 V AC<br>100–240 V AC<br>24 V DC<br>24 V DC<br>100–240 V AC<br>100–240 V AC<br>24 V DC<br>24 V DC|
|Integrated inputs|24<br>24<br>24<br>24<br>36<br>36<br>36<br>36|
|Integrated outputs|16<br>16<br>16<br>16<br>24<br>24<br>24<br>24|
|Output type<br>Power consumption|Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>Relay<br>Transistor<br>(source)*<br>W 37<br>37<br>25<br>25<br>40<br>40<br>29<br>29|
|Weight|kg 0.70<br>0.70<br>0.70<br>0.70<br>0.85<br>0.85<br>0.85<br>0.85|
|Dimensions (WxHxD)|mm 130x90x86<br>130x90x86<br>130x90x86<br>130x90x86<br>175x90x86<br>175x90x86<br>175x90x86<br>175x90x86|
* Sink type transistor output units on request.
17
Base Units FX3GE Series
~~**2**~~
## **The MELSEC FX3GE series**
## **Integrated high-speed counter inputs**
for processing fast input signals. For example, you can configure two 60 kHz counters and four 10 kHz counters. **Interrupt processing** is also handled via the inputs.
RAM/EEPROM memory for up to **32,000 PLC program steps** gives you plenty of reserve, even for big, complex applications.
Add-in function boards can be installed in the PLC to provide a **second RS485/RS422/**
**==> picture [209 x 202] intentionally omitted <==**
**----- Start of picture text -----**<br>
RS232 communications interface for<br>programming or network configurations.<br>Analog function boards for input and<br>output and a function board with 8 analog<br>potentiometers are also available as add-in.<br>gee<br>lh<br>Connection possibility for special tl<br>function adapter modules<br>An integrated RUN/STOP switch<br>is available.<br>Two integrated serial interfaces for<br>direct communication with computers.<br>**----- End of picture text -----**<br>
The base units can be expanded to provide configurations with up to 256 inputs and outputs with modular and **compact extension units** (128 directly and 256 in common by using remote I/Os via a network).
**==> picture [70 x 25] intentionally omitted <==**
**----- Start of picture text -----**<br>
Integrated real-time<br>clock with year, month,<br>day and time<br>**----- End of picture text -----**<br>
Two **integrated pulse outputs** for frequencies from 2 to 100,000 Hz for controlling stepping motors and outputting **pulse-width modulated signals.**
## **Description of the unit components**
**==> picture [476 x 255] intentionally omitted <==**
**----- Start of picture text -----**<br>
e_—_—__ Terminal cover<br>Memory cassette, display module,<br>and extension board connector<br>Terminal protector<br>= | Sexe! i<br>Terminals for digital inputs<br>Terminals for analog inputs Se—<br>aie == Ale Seah)!<br>VSR AAS t LEDs for input status<br>2 analog potentiometers<br>RUN/STOP switch<br>nis e e ae Battery bracket<br>Connection for adapter modules img | = # me<br>Operation status indicator LEDs<br>RS-422 interface<br>a oe<br>USB interface Cover for the extension slot<br>RJ45 socket (10BASE-T/100BASE-TX) LEDs for output status<br>e e<br>Terminals for analog output \ as ! Terminals for digital outputs<br>Terminal protector<br>Terminal cover<br>———<br>Cover for interface, potentiometer and i MITSUBISHI MELSEC: Cover for the extension slot and<br>RUN/STOP switch _ee the optional battery<br>LOT<br>INPUTANALOG V1+ I1+ V2+ I2+ VI-<br>100M<br>SD/RD<br>ERR<br>OPEN<br>10BASE-T/100BASE-TX<br>V+ I+ VI-<br>OUTPUTANALOG<br>**----- End of picture text -----**<br>
Cover for interface, potentiometer and RUN/STOP switch
18
Base Units FX3GE Series
~~**2**~~
## ~~**Base units**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** þ~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Base units FX3GE**
The FX3GE series base units are available with 24 or 40 input/output points.
All base units are equipped with relay outputs.
- z Integrated analog input (2ch)
- z Integrated analog output (1ch)
- z Integrated Ethernet interface
- z Integrated USB interface for communication between PLC and PC
- z Integrated serial interface for communication between PLC and HMI
- z Connection of inputs and outputs via terminals
- z Slot for memory cassettes
- z Integrated positioning control
- z Expandable with special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
- z LEDs for indicating the input and output status
## **Base units with 24 I/Os**
|**Specifications**|**FX3GE-24**<br>**MR/ES**|**FX3GE-24**<br>**MT/ESS**|**FX3GE-24**<br>**MR/DS**<br>**FX3GE-24**<br>**MT/DSS**|
|---|---|---|---|
|||||
|Max. number inputs/outputs|24|24|24<br>24|
|Power supply|100–240 V AC|100–240 V AC|24 V DC<br>24 V DC|
|Integrated inputs|14|14|14<br>14|
|Integrated outputs|10|10|10<br>10|
|Output type|Relay|Transistor<br>(source)*|Relay<br>Transistor<br>(source)*|
|||||
|Power consumption<br>W|32|32|21<br>21|
|Weight<br>kg|0.6|0.55|0.55<br>0.55|
|Dimensions (WxHxD)<br>mm|130x90x86|90x90x86|90x90x86<br>90x90x86|
|||||
|**Order information**<br>Art. no. 264869|Art. no. 264869|269884|269917<br>269919|
## **Base units with 40 I/Os**
|**Specifications**|**FX3GE-40**<br>**MR/ES**<br>**FX3GE-40**<br>**MT/ESS**<br>**FX3GE-40**<br>**MR/DS**|**FX3GE-40**<br>**MT/DSS**|
|---|---|---|
||||
|Max. number inputs/outputs|40<br>40<br>40|40|
|Power supply|100–240 V AC<br>100–240 V AC<br>24 V DC|24 V DC|
|Integrated inputs|24<br>24<br>24|24|
|Integrated outputs|16<br>16<br>16|16|
|Output type|Relay<br>Transistor<br>(source)*<br>Relay|Transistor<br>(source)*|
||||
|Power consumption<br>W|37<br>37<br>25|25|
|Weight<br>kg|0.8<br>0.70<br>0.70|0.70|
|Dimensions (WxHxD)<br>mm|175x90x86<br>130x90x86<br>130x90x86|130x90x86|
||||
|**Order information**<br>Art. no. 264870|Art. no. 264870<br>269916<br>269920|269922|
* Sink type transistor output units on request.
19
Base Unit FX3GC Series
~~**2** .~~
## **The MELSEC FX3GC series**
**==> picture [473 x 297] intentionally omitted <==**
**----- Start of picture text -----**<br>
RAM/EEPROM memory for up to<br>32,000 PLC program steps gives<br>Integrated high-speed counter inputs you plenty of reserve, even for big,<br>for processing fast input signals. For complex applications.<br>example, you can configure two 60 kHz<br>counters and four 10 kHz counters.<br>Interrupt processing is also handled<br>The base units can be expanded to<br>via the inputs.<br>provide configurations with up to<br>= 256 inputs and outputs with modular<br>—— an and compact extension units<br>(128 directly and 256 in common by<br>‘eS using remote I/Os via a network).<br>An integrated RUN/STOP<br>switch is available.<br>Integrated real-time<br>clock with year, month,<br>day and time<br>Two integrated serial interfaces for WAIN) IN S NNS !<br>direct communication with computers. NNW) I NN I S<br>XQ WA \\ ay<br>Two integrated pulse outputs for<br>frequencies from 2 to 100,000 Hz for con-<br>Connection possibility for special<br>trolling stepping motors and outputting<br>function adapter modules<br>pulse-width modulated signals.<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [483 x 272] intentionally omitted <==**
**----- Start of picture text -----**<br>
Operation status indicator LEDs<br>0<br>Protective cover for the<br>a) . ———_ MITSUBISHI eee | extension bus<br>USB interface for peripheral devices<br>market aa Ad RUN/STOP switch<br>Input indicator LEDs a uJ<br>RS422 interface for<br>peripheral devices<br>Cover for adapter<br>module connection<br>Output indicator LEDs<br>IVa<br>Adapter module connection — qo or o o Neg e<br>Connector for digital outputs<br>Connector for digital inputs<br>i 491<br>ii |<br>Battery connector<br>i<br>Back-up battery<br>fe)<br>|<br>Battery cover<br>**----- End of picture text -----**<br>
20
Base Unit FX3GC Series
~~**2**~~
## ~~**Base unit**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** þ~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Base unit FX3GC**
The base unit FX3GC-32 MT/DSS (FX3GC series) is available with 32 input/output points.
The base unit is equipped with transistor outputs.
- z Integrated USB interface for communication between PLC and PC
- z Integrated serial interface for communication between PLC and HMI
- z Integrated positioning control
- z Expandable with digital I/O modules, special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
- z LEDs for indicating the input and output status
- z Connection of inputs and outputs via connectors.
## **Base unit with 32 I/Os**
|**Specifications**|**FX3GC-32 MT/DSS**|
|---|---|
|||
|Max. number inputs/outputs|32|
|Power supply|24 V DC|
|Integrated inputs|16|
|Integrated outputs|16|
|Output type|Transistor (source)|
|||
|Power consumption<br>W|8|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|34x90x87|
|||
|**Order information**<br>Art. no. 251546|Art. no. 251546|
21
Base Units FX3G/FX3GC/FX3GE Series
~~**2**~~
## ~~�~~ ~~**[Specifications]**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Environmental specifications**
**==> picture [512 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications FX3G FX3GE FX3GC<br>Ambient temperature 0–55 °C (storage temperature: -25–+75 °C)<br>Noise durability 1000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage 1500 V AC, 1 min 500 V AC, 1 min<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC 68-2-27: 15 g (147 m/s2) (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC 68-2-6: 1 g (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting<br>Insulation resistance 5 MΩ, 500 V DC<br>Ground Class D: Grounding resistance 100 Ω or less<br>For FX3G-14Mm and FX3G-24Mm: 250 V 1 A; FX3GE-24Mm: 250 V 1 A;<br>Fuse rating For FX3G-40Mm and FX3G-60Mm: 250 V 3.15 A FX3GE-40Mm: 250 V 3.15 A 125 V 3,15 A<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 66–67<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply FX3G FX3GE FX3GC<br>specifications<br>AC 100–240 V (+10 % /-15 %), 50/60 Hz —<br>Power supply<br>DC 24 V DC (+20 %/-15 %)<br>AC [30 A/<5 ms (at 100 V AC); ] —<br>50 A/<5 ms (at 200 V AC)<br>Inrush current at ON<br>30 A/<0.5 ms<br>DC 30 A/<1 ms (at 24 V DC) (at 24 V DC)<br>Allowable momentary power 10 ms 10 ms 5 ms<br>failure time<br>External power supply 400 mA 400 mA —<br>(24 V DC)<br>**----- End of picture text -----**<br>
**==> picture [250 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
Relay modules Transistor modules Transistor modules<br>Output specifications FX3G/FX3GE FX3G/FX3GE FX3GC<br>Switching voltage (max.) V <240 V AC, <30 V DC 5–30 V DC 5–30 V DC<br>Max. output - per output A 2 0,5 Y000, Y001: 0.3Y002–Y017: 0.1<br>current<br>- per group A 8 [b] 0,8 [b] 0,8<br>Max. switch-<br>ing - inductive load W 80 VA 12 W Y000, Y001: 7.2Y002–Y017 : 2.4<br>current<br><0.2 <0.2<br>Response time ms 10 (<5 µs for Y0,Y1) [1] (<5 µs for Y0,Y1)<br>**----- End of picture text -----**<br>
a The 40 and 60 I/O pointsmain units supports 5 μs for Y2.
b This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and 2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
## **Programming specifications**
**==> picture [251 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3G FX3GE FX3GC<br>Program data<br>I/O points (addresses) 256 total (combined local and CC-Link remote I/O)<br>Address range Max. 128 direct addressing andmax. 128 remote I/O<br>Program memory 32,000 steps EEPROM (internal), exchangeable EEPROM memory cassette<br>Cycle period 0.21 μs or 0.42 μs/contact instruction<br>29 sequence instructions,<br>Number of instructions 29 sequence instructions, 2 step ladder 2 step ladder instructions,<br> instructions, 123 applied instructions 122 applied instructions<br>Programming language Step ladder, instruction list, SFC<br>Program execution Cyclical execution, refreshmode processing<br>Program protection Via password<br>**----- End of picture text -----**<br>
**==> picture [250 x 225] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3G FX3GE FX3GC<br>Operands<br>Internal relays 7,680<br>Special relays 512<br>Step ladder 4,096<br>Timer 320<br>Ext. preset value via 2<br>potentiometer<br>Counter 235<br>6 single phase inputs (max. 60 kHz),<br>High-speed counter 3 double phase inputs (max. 30 kHz)<br>Real-time clock Year, month, day, hour, minute, second, weekday<br>Data register 8,000<br>File register 24,000 (R0~R23999) internal/optional memory 24,000 (R0~R23999)<br>Extension file register 24,000 (ER0~ER23999)<br>Index register 16<br>Special register 512 (D8000–D8511)<br>Pointer 2,048<br>Nestings 8<br>Interrupt inputs 6<br>16 bits: K: -32768–+32767, hex: 0–FFFF<br>Constants 32 bits: K: 2147483648–+2147483647,<br>hex: 0–FFFF FFFF<br>**----- End of picture text -----**<br>
22
Base Units FX3U Series
~~**2**~~
## **The MELSEC FX3U series**
**==> picture [510 x 329] intentionally omitted <==**
**----- Start of picture text -----**<br>
Integrated high-speed counter inputs for<br>processing fast input signals. For example,<br>you can configure six 100 kHz counters and<br>two 10 kHz counters.<br>RAM/EEPROM memory for up to<br>Interrupt processing is also handled via<br>64,000 PLC program steps gives<br>the inputs.<br>you plenty of reserve, even for big,<br>complex applications.<br>——_<br>The base units can be expanded to provide<br>Add-in function boards can be installed in configurations with up to 384 inputs and<br>the PLC to provide a second RS485/RS422/ outputs with compact extension units<br>RS232/USB communications interface for (total of 384 only by using main unit I/Os,<br>programming or network configurations. ~ a extension unit I/Os and remote I/Os).<br><p ge i<br>ESSx pxpre<br>rs See ZF<br>An integrated RUN/STOP switch Integrated real-time clock with<br>is available. year, month, day and time<br>Connection possibility for<br>special function adapter modules<br>Three integrated pulse outputs for frequen-<br>cies up to 100 kHz with deceleration and<br>acceleration ramps for controlling stepping<br>Integrated serial interface motors and outputting pulse-width modu-<br>for direct communication with lated signals .<br>computers<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [502 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
Battery cover<br>Protective cover<br>Terminal block cover<br>y aa n<br>Input terminals<br>I:=oN<br>Battery Input indicator LEDs<br>Operation status indicator LEDs<br>Installation place for FX3U-7DM<br>Extension device connecting<br>| ‘ps iN of \ )) [/— es \ connector cover<br>Expansion board dummy cover Output indicator LEDs<br>RUN/STOP switch<br>—<br>| Output terminals<br>Periphal device Terminal block cover<br>[eieloteleselelerorerele r=)<br>connecting connector<br>Top cover with Model name Protective cover<br>(used, if FX3U-7DM<br>is not installed)<br>**----- End of picture text -----**<br>
23
Base Units FX3U Series
~~**2**~~
## ~~**Base units**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Base units FX3U**
The FX3U series base units are available with 16, 32, 48, 64, 80 or 128 input/output points expandable to 384 points.
Models are available for selection with relay or transistor outputs.
- z Integrated serial interface for communication between PCs and HMI
- z Integrated positioning control
- z Exchangeable interface modules for direct mounting into a base unit
- z LEDs for indicating the input and output status
- z Slot for memory cassettes
- z Integrated real-time clock
- z Expandable with digital I/O modules, special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
## **Base units with 16 I/Os**
|**Specifications**|**FX3U-16**<br>**MR-DS**<br>**FX3U-16**<br>**MR/ES**<br>**FX3U-16**<br>**MT/DSS**<br>**FX3U-16**<br>**MT/ESS**|
|---|---|
|Max. number inputs/outputs|16<br>16<br>16<br>16|
|Power supply|24 V DC<br>100–240 V AC<br>24 V DC<br>100–240 V AC|
|Integrated inputs|8<br>8<br>8<br>8|
|Integrated outputs|8<br>8<br>8<br>8|
|Output type|Relay<br>Relay<br>Transistor<br>(source)<br>Transistor<br>(source)|
|||
|Power consumption|25 W<br>30 VA<br>25 W<br>30 VA|
|Weight<br>kg|0.6<br>0.6<br>0.6<br>0.6|
|Dimensions (WxHxD)<br>mm|130x90x86<br>130x90x86<br>130x90x86<br>130x90x86|
|||
|**Order information**<br>Art. no. 231498|Art. no. 231498<br>231486<br>231503<br>231492|
## **Base units with 32 I/Os**
|**Specifications**|**FX3U-32**<br>**MR/DS**<br>**FX3U-32**<br>**MR/ES**<br>**FX3U-32**<br>**MT/DSS**<br>**FX3U-32**<br>**MT/ESS**|
|---|---|
|||
|Max. number inputs/outputs|32<br>32<br>32<br>32|
|Power supply|24 V DC<br>100–240 V AC<br>24 V DC<br>100–240 V AC|
|Integrated inputs|16<br>16<br>16<br>16|
|Integrated outputs|16<br>16<br>16<br>16|
|Output type|Relay<br>Relay<br>Transistor<br>(source)<br>Transistor<br>(source)|
|||
|Power consumption|30 W<br>35 VA<br>30 W<br>35 VA|
|Weight<br>kg|0.65<br>0.65<br>0.65<br>0.65|
|Dimensions (WxHxD)<br>mm|150x90x86<br>150x90x86<br>150x90x86<br>150x90x86|
|||
|**Order information**<br>Art. no. 231499|Art. no. 231499<br>231487<br>231504<br>231493|
Note: Further special versions are available on request
24
Base Units FX3U Series
~~**2**~~
## **Base units with 48 I/Os**
**==> picture [512 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-48 FX3U-48 FX3U-48 FX3U-48<br>Specifications MR/DS MR/ES MT/ESS MT/DSS<br>Max. number inputs/outputs 48 48 48 48<br>Power supply 24 V DC 100–240 V AC 100–240 V AC 24 V DC<br>Integrated inputs 24 24 24 24<br>Integrated outputs 24 24 24 24<br>Transistor Transistor<br>Output type Relay Relay<br>(source) (source)<br>Power consumption 35 W 40 VA 40 VA 35 W<br>Weight kg 0.85 0.85 0.85 0.85<br>Dimensions (WxHxD) mm 182x90x86 182x90x86 182x90x86 182x90x86<br>Order information Art. no. 231500 231488 231494 231505<br>**----- End of picture text -----**<br>
## **Base units with 64 I/Os**
**==> picture [512 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-64 FX3U-64 FX3U-64 FX3U-64<br>Specifications MR/DS MR/ES MT/ESS MT/DSS<br>Max. number inputs/outputs 64 64 64 64<br>Power supply 24 V DC 100–240 V AC 100–240 V AC 24 V DC<br>Integrated inputs 32 32 32 32<br>Integrated outputs 32 32 32 32<br>Transistor Transistor<br>Output type Relay Relay<br>(source) (source)<br>Power consumption 40 W 45 VA 45 VA 40 W<br>Weight kg 1.0 1.0 1.0 1.0<br>Dimensions (WxHxD) mm 220x90x86 220x90x86 220x90x86 220x90x86<br>Order information Art. no. 231501 231489 231495 231506<br>**----- End of picture text -----**<br>
## **Base units with 80–128 I/Os**
**==> picture [512 x 135] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-80 FX3U-80 FX3U-80 FX3U-80 FX3U-128 FX3U-128<br>Specifications MR/DS MR/ES MT/DSS MT/ESS MR/ES MT/ESS<br>Max. number inputs/outputs 80 80 80 80 128 128<br>Power supply 24 V DC 100–240 V AC 24 V DC 100–240 V AC 100–240 V AC 100–240 V AC<br>Integrated inputs 40 40 40 40 64 64<br>Integrated outputs 40 40 40 40 64 64<br>Transistor Transistor Transistor<br>Output type Relay Relay Relay<br>(source) (source) (source)<br>Power consumption 45 W 50 VA 45 W 50 VA 65 VA 65 VA<br>Weight kg 1.2 1.2 1.2 1.2 1.8 1.8<br>Dimensions (WxHxD) mm 285x90x86 285x90x86 285x90x86 285x90x86 350x90x86 350x90x86<br>Order information Art. no. 231502 231490 231507 231496 231491 231497<br>**----- End of picture text -----**<br>
25
Base Units FX3U Series
~~**2**~~
## ~~�~~ ~~**[Specifications]**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Environmental specifications**
**==> picture [512 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Data<br>Ambient temperature 0–55 °C (storage temperature: -25–+75 °C)<br>Protection IP10<br>Noise durability 1000 Vpp with noise generator; 1 µs at 30–100 Hz<br>Dielectric withstand voltage AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC 68-2-27: 15 g (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC 68-2-6: 1 g (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting<br>Insulation resistance 5 MΩ, 500 V DC<br>Ground Class D: Grounding resistance 100 Ω or less<br>Fuse rating From FX3U-16Mm to FX3U-32Mm: 3.15 A; from FX3U-48Mm to FX3U-128Mm: 5 A<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 66–67<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 100] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply DC powered modules AC powered modules<br>specifications (FX3U- m M m /DS/DSS) (FX3U- m MR/ES)<br>100–240 V AC (+10 %/-15 %),<br>Power supply 24 V DC (+20 %/-30 %) 50/60 Hz<br>Inrush current at ON — 30 A/<5 ms (at 100 V AC);<br>65 A/<5 ms (at 200 V AC)<br>Allowable momentary power 5 ms 10 ms<br>failure time<br>Primary power supply 24 V DC —<br>External power supply (24 V DC) — FX3U-16/32MR/ES: 400 mA/ FX3U-48–128MR/ES: 600 mA<br>**----- End of picture text -----**<br>
**==> picture [250 x 96] intentionally omitted <==**
**----- Start of picture text -----**<br>
Relay- Transistor-<br>Output specifications modules modules<br>Switching voltage (max.) V <240 V AC, <30 V DC 5–30 V DC<br>Max. output - per output A 2 0.5/0.3 [ a]<br>current - per group* A 8 0.8/1.6 [b]<br>Max. switching - inductive load 80 VA 12 W/7.2 W<br>current<br>Response time ms 10 <0.2 (Y0,Y1<30 µs)<br>3,000,000 at 20 VA; 1,000,000 at 35 VA;<br>Life of contacts (switching times) [c] 200,000 at 80 VA<br>**----- End of picture text -----**<br>
a or Y0 and Y1 = 0.3 A; all others 0.5 A b 0.8 for 4 per group and 1.6 for 8 per group
c Not guaranteed by Mitsubishi Electric.
* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and 2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
## **Programming specifications**
**==> picture [251 x 118] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3U<br>Program data<br>I/O points (addresses) Max. total 384 (with remote I/O)<br>Address range Max. 256 direct addressing and max. 256 network I/Os<br>64,000 steps RAM (internal),<br>Program memory exchangeable FLROM for easy program exchange<br>Cycle period 0.065 µs/basic instruction<br>Number of instructions 27 sequence instructions, 2 step ladder instructions,<br>209 applied instructions<br>Programming language Step ladder, instruction list, SFC<br>Program execution Cyclical execution, refresh mode processing<br>Program protection Password protection with 3 protection levels*<br>**----- End of picture text -----**<br>
* Protection levels may only be changed with FX-10P/FX-20P/FX-30P.
**==> picture [250 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3U<br>Operands<br>Internal relays 7,680<br>Special relays 512<br>Step ladder 4,096<br>Timer 512<br>Counter 235<br>High-speed counter 16<br>1 phase, 8 points max: 100 kHz/6 points<br>High-speed counter speed 10 kHz/2 points<br>2 phase, 2 points max: 50 kHz/2 points<br>Real-time clock Year, month, day, hour, minute, second, weekday<br>Data register 8,000<br>Extension file register 32,768<br>Index register 16<br>Special register 512<br>Pointer 4,096<br>Nestings 8<br>Interrupt inputs 6<br>16 bits: K: -32768–+32767, hex: 0–FFFF<br>Constants 32 bits: K: 2147483648–+2147483647,<br>hex: 0–FFFF FFFF<br>**----- End of picture text -----**<br>
26
Base Units FX3UC Series
~~**2**~~
## **The MELSEC FX3UC series**
**==> picture [445 x 282] intentionally omitted <==**
**----- Start of picture text -----**<br>
Integrated RUN/STOP switch<br>Integrated serial interface<br>for direct communication RAM/EEPROM memory for up to<br>64,000 PLC program steps gives<br>with computers SN<br>you plenty of reserve, even for big,<br>complex applications.<br>\:e<br>|<br>Interface adapter connection for The base units can be expanded<br>second communications interface to provide configurations with<br>RS485/RS422/RS232 up to 384 inputs and outputs<br>with compact extension units<br>(total of 384 only by using main<br>unit I/Os, extension unit I/Os<br>and remote I/Os).<br>Integrated high-speed counter inputs for processing N<br>fast input signals. For example, you can configure<br>six 100 kHz counters and two 10 kHz counters. Three integrated pulse outputs for frequencies<br>Interrupt processing is also handled via the inputs. up to 100 kHz with deceleration and acceleration<br>ramps for controlling stepping motors and output-<br>ting pulse-width modulated signals .<br>**----- End of picture text -----**<br>
## **Description of the unit components**
**==> picture [494 x 250] intentionally omitted <==**
**----- Start of picture text -----**<br>
RUN/STOP switch Input indicator LEDs<br>Operation status indicator LEDs<br>Output indicator LEDs<br>Slot for memory cassettes<br>Protective cover for the<br>extension bus<br>Memory cassette<br>(optional)<br>—___} \ ‘|)"8e 0<br>Extension bus (lateral)<br>Connection for<br>programming units<br>Cover for adapter<br>module connection<br>Back-up battery ——.Q\ ;A), Connector for digital outputs<br>Battery cover<br>rr) Connector for digital inputs<br>**----- End of picture text -----**<br>
27
Base Units FX3UC Series
~~**2**~~
## ~~**Base units**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Base units FX3UC**
The base units of the FX3UC series are available in versions with 16, 32, 64 or 96 inputs/outputs (expandable to 384 I/Os).
The units are available with transistor outputs only.
- z Integrated serial interface for communication between PCs and HMI
- z Same instruction set as FX3U
- z Integrated positioning control
- z Very compact dimensions
- z LEDs for indicating the input and output status
- z Slot for memory cassette
- z Adapter modules and system cabling sets available for units with ribbon cable connectors
- z Expandable with digital I/O modules, special function modules and ADP modules
- z User-friendly programming systems, including IEC 61131-3 (EN 61131-3) compatible programming software, HMIs and hand-held programming units
## **Base units with 16–96 I/Os**
|**Specifications**|**FX3UC-16**<br>**MT/DSS**<br>**FX3UC-32**<br>**MT/DSS**<br>**FX3UC-64**<br>**MT/DSS**<br>**FX3UC-96**<br>**MT/DSS**|
|---|---|
|Max. number inputs/outputs|16<br>32<br>64<br>96|
|Power supply|24 V DC(+20 %,-15 %)<br>24 V DC(+20 %,-15 %)<br>24 V DC(+20 %,-15 %)<br>24 V DC(+20 %,-15 %)|
|Integrated inputs|8<br>16<br>32<br>48|
|Integrated outputs|8<br>16<br>32<br>48|
|Output type|Transistor (source)*<br>Transistor (source)*<br>Transistor (source)*<br>Transistor (source)*|
|||
|Power consumption<br>W|6<br>8<br>11<br>14|
|Weight<br>kg|0.2<br>0.2<br>0.3<br>0.35|
|Abmessungen (B x H x T)<br>mm|34x90x74<br>34x90x74<br>59.7x90x74<br>85.4x90x74|
|||
|**Order information**<br>Art. no. 231508|Art. no. 231508<br>231509<br>231510<br>231511|
* Units with sink type transistor outputs on request.
## **System cabling**
A choice of terminal blocks with screw or spring terminals are available for easy wiring of the FX3UC modules with standard ribbon cable connectors.
For detailed information about the terminal blocks, please refer to the FX Family catalogue.
**==> picture [109 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output terminal block with screw or<br>spring terminals. It can be fitted with<br>relay or transistor outputs.<br>**----- End of picture text -----**<br>
**==> picture [223 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input terminal block with screw<br>or spring terminals.<br>i <a) plae|<br>a ll<br>.0 .1 .2 .3 .4 .5 .6 .7<br>A2- A2- A2- A2- A2- A2- A2- A2-<br>24V 24V 24V 24V 24V 24V 24V 24V<br>.0 .1 24V+.2 .3 -PLC-V8/FLK14/OUT.4Art. 22 95 55 4.5 .6 .7<br>**----- End of picture text -----**<br>
28
Base Units FX3UC Series
~~**2**~~
## ~~�~~ ~~**[Specifications]** ¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Environmental specifications**
**==> picture [512 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
General specifications Data<br>Ambient temperature 0–55 °C (storage temperature: -25–+75 °C)<br>Protection IP10<br>Noise durability 1000 Vpp with noise generator; 1 µs bei 30–100 Hz<br>Dielectric withstand voltage AC PSU: 1500 V AC, 1 min./DC PSU: 500 V AC, 1 min.<br>Ambient relative humidity 5–95 % (non-condensing)<br>Shock resistance Acc. to IEC 68-2-27: 15 g (3 times each in 3 directions for 11 ms)<br>Vibration resistance Acc. to IEC 68-2-6: 1 g (resistance to vibrations from 57–150 Hz for 80 minutes along all 3 axes); 0.5 g for DIN rail mounting<br>Insulation resistance 500 V DC, 5 MΩ<br>Ground Class D: Grounding resistance 100 Ω or less<br>Environment Avoid environments containing corrosive gases, install in a dust-free location.<br>Certifications Please refer to pages 66–67<br>**----- End of picture text -----**<br>
## **Electrical specifications**
**==> picture [251 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply Alle modules<br>specifications<br>Power supply 24 V DC (+20 %/-30 %)<br>Inrush current at ON —<br>Allowable momentary power 5 ms<br>failure time<br>Primary power supply 24 V DC<br>External power supply (24 V DC) —<br>**----- End of picture text -----**<br>
**==> picture [250 x 88] intentionally omitted <==**
**----- Start of picture text -----**<br>
Output specifications Alle modules<br>Switching voltage (max.) V 5–30 V DC<br>Max. output - per output A 0.1/0.3 [a]<br>current - per group* A 0.8/1.6<br>Max. switching - inductive load 2.4 W/7.2 W [b]<br>current<br>Response time ms <0.2 (Y0,Y1<30 µs)<br>3,000,000 at 20 VA; 1,000,000 at 35 VA;<br>Life of contacts (switching times) [ c] 200,000 at 80 VA<br>**----- End of picture text -----**<br>
a or Y0 and Y1 = 0.3 A; all others 0.1 A b 7.2 W for Y0 to Y3, all other outputs 2.4 W
c Not guaranteed by Mitsubishi Electric.
* This limitation applies only per reference terminal for each group, 4 and 8 outputs for relays and 2 and 4 outputs for transistors. Please observe the terminal assignments for the group identification.
## **Programming specifications**
**==> picture [250 x 119] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3UC<br>Program data<br>I/O points (addresses) Max. total 384 (with remote I/O)<br>Address range Max. 256 direct addressing and max. 256 network I/Os<br>64,000 steps RAM (internal), exchangeable FLROM for<br>Program memory easy program exchange<br>Cycle period 0.065 µs/basic instruction<br>Number of instructions 27 sequence instructions, 2 step ladder instructions,<br>209 applied instructions<br>Programming language Step ladder, instruction list, SFC<br>Program execution Cyclical execution, refresh mode processing<br>Program protection Password protection with 3 protection levels*<br>**----- End of picture text -----**<br>
* Protection levels may only be changed with FX-30P.
**==> picture [250 x 215] intentionally omitted <==**
**----- Start of picture text -----**<br>
System specifications FX3UC<br>Operands<br>Internal relays 7,680<br>Special relays 512<br>Step ladder 4,096<br>Timer 512<br>Counter 235<br>High-speed counter 16<br>1 phase, 8 points max: 100 kHz/6 points<br>High-speed counter speed 10 kHz/2 points<br>2 phase, 2 points max: 50 kHz/2 points<br>Real-time clock Year, month, day, hour, minute, second, weekday<br>Data register 8,000<br>Extension file register 32,768<br>Index register 16<br>Special register 512<br>Pointer 4,096<br>Nestings 8<br>Interrupt inputs 6<br>16 bits: K: -32768–+32767, hex: 0–FFFF<br>Constants 32 bits: 2K: 147483648–+2147483647,<br>hex: 0–FFFF FFFF<br>**----- End of picture text -----**<br>
29
Compact Extension Units
~~**3**~~
## ~~**Powered compact extension units**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Extension units FX2N**
The FX2N series extension units are available with 32 or 48 input/output points.
It is possible to choose between relay and transistor output type.
- z LEDs for indicating the input and output status
- z MELSEC FX3G/FX3GE and FX3U series compatible
- z Detachable terminal blocks
- z Integrated service power supply with 250 mA or 460 mA
|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|**Electrical data**|
|---|---|---|---|---|---|---|
|Integrated inputs/outputs|32<br>32<br>48<br>48<br>48<br>48||||||
|Power supply<br>AC range(+10 %<br>frequencyat AC<br>DC range(+20 %|+10 %,-15 %)<br>100–240 V<br>100–240 V<br>—<br>100–240 V<br>—<br>100–240 V||||||
||at AC<br>Hz 50/60<br>50/60<br>—<br>50/60<br>—<br>50/60||||||
||+20 %,-30 %)<br>—<br>—<br>24 V<br>—<br>24 V<br>—||||||
|Max. input apparentpower|35 VA<br>30 W<br>45 VA<br>30 W<br>45 VA||||||
|Inrush current at ON|100 V AC 40 A<5 ms<br>40 A<5 ms<br>—<br>40 A<5 ms<br>40 A<5 ms<br>40 A<5 ms||||||
||200 V AC 60 A<5 ms<br>—<br>—<br>60 A<5 ms<br>60 A<5 ms<br>60 A<5 ms||||||
|Allowable momentary power failure time|ower failure time<br>ms 10<br>10<br>5<br>10<br>5<br>10||||||
|External servicepower supply (24 V DC|24 V DC)<br>mA 250<br>250<br>—<br>460<br>—<br>460||||||
|Power supplyint. bus(5 V DC)|mA 690<br>690<br>690<br>690<br>690<br>690||||||
|**Inputs**|||||||
|Integrated inputs|16<br>16<br>24<br>24<br>24<br>24||||||
|Min. current for logical 1|mA 3.5<br>3.5<br>3.5<br>3.5<br>3.5<br>3.5||||||
|Max. current for logical 0|mA 1.5<br>1.5<br>1.5<br>1.5<br>1.5<br>1.5||||||
|Response time|For all extension units of the MELSEC FX2N series: 10 ms(at time of shipment)||||||
|**Outputs**|||||||
|Integrated outputs|16<br>16<br>24<br>24<br>24<br>24||||||
|Output type|Relay<br>Transistor<br>(source)<br>Relay<br>Relay<br>Transistor<br>(source)<br>Transistor<br>(source)||||||
|Switchingvoltage(max.)|Generallyfor relayversion: <264 V AC,<30 V DC;for transistor version: 5–30 V DC||||||
|Max. output<br>current<br>-per output<br>-pergroup*|A 2<br>0.5<br>2<br>2<br>0.5<br>0.5||||||
||*<br>A 8<br>0.8/1.6b<br>8<br>8<br>0.8/1.6b<br>0.8 /1.6b||||||
|Max. Schaltleistung<br>- inductive load|- inductive load<br>W 80<br>12<br>80<br>80<br>12<br>12||||||
|Response time|ms 10<br><0.2<br>10<br>10<br><0.2<br><0.2||||||
|Life of contacts(switchingtimes)a|For all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA;1,000,000 at 35 VA;200,000 at 80 VA(for relayoutput only)||||||
|**Mechanical data**|||||||
|Weight|kg 0.65<br>0.65<br>0.85<br>0.85<br>0.85<br>0.85||||||
|Dimensions (WxHxD)|mm 150x90x87<br>150x90x87<br>182x90x87<br>182x90x87<br>182x90x87<br>182x90x87||||||
a Not guaranteed by Mitsubishi Electric b 0.8 for 4 per group and 1.6 for 8 per group
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
30
Modular Extension Units
~~**3**~~
## ~~**Unpowered modular extension blocks**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Extension blocks FX2N**
**==> picture [135 x 120] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX2N-8EX-ES at -<br>OUT<br>OUT<br>IN<br>2<br>**----- End of picture text -----**<br>
The FX2N series modular extension blocks are available with 8 or 16 input/output points. It is possible to choose between relay and transistor output type.
- z LEDs for indicating the input and output status
- z MELSEC FX3G/FX3GC/FX3GE and FX3U series compatible
- z Very compact dimensions
- z Vertically terminal blocks with a cable guide to the upper or lower side
FX2N-16EYR-ES/UL
|**Electrical data**|**Electrical data**|
|---|---|
|rated inputs/outputs|8<br>8<br>8<br>8<br>16<br>16<br>16|
|Nbr. of occupied I/Opoints in the PLC|16<br>8<br>8<br>8<br>16<br>16<br>16|
|pply|All modular extension blocks are supplied bythe base unit.|
|||
|rated inputs|4<br>8<br>—<br>—<br>16<br>—<br>—|
|Min. current for logical 1<br>mA|3.5<br>3.5<br>—<br>—<br>3.5<br>—<br>—|
|Max. current for logical 0<br>mA|1.5<br>1.5<br>—<br>—<br>1.5<br>—<br>—|
|onse time|For all extension blocks of the MELSEC FX2N series: 10 ms(at time of shipment)|
|||
|rated outputs|4<br>—<br>8<br>8<br>—<br>16<br>16|
|Output type|Relay<br>—<br>Relay<br>Transistor<br>—<br>Relay<br>Transistor<br>(source)|
|gvoltage(max.)|Generallyfor relayversion: <240 V AC,<30 V DC;for transistor version: 5–30 V DC|
|Max. output current<br>-per output<br>A <br>-pergroup a<br>A|2<br>—<br>2<br>0.5<br>—<br>2<br>0.5|
||8<br>—<br>8<br>0.8<br>—<br>8<br>1.6|
|Max. Schaltleistung<br>- inductive load<br>VA|80<br>—<br>80<br>12<br>—<br>80<br>12|
|onse time<br>ms|10<br>10<br>10<br><0.2<br>—<br>10<br><0.2|
|Life of contacts(switchingtimes) b|For all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA;1,000,000 at 35 VA;200,000 at 80 VA(for relayoutput only)|
|**Mechanical data**||
|kg|0.2<br>0.2<br>0.2<br>0.2<br>0.3<br>0.3<br>0.3|
|Dimensions (WxHxD)<br>mm|43x90x87<br>43x90x87<br>43x90x87<br>43x90x87<br>40x90x87<br>40x90x87<br>40x90x87|
a This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification. b Not guaranteed by Mitsubishi Electric Note: To connect these modules to a FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
31
Modular Extension Units
~~**3**~~
## ~~**Modular extension units**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** þ~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
**==> picture [146 x 195] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tes<br>a<br>Ns 7<br>Ve DA<br>°<br>FX2NC-32EX-DS<br>FX2NC-16EYR-DS<br>FX2NC-16EYR-T-DS<br>FX2NC-DS -32EX<br>PWY0Y4Y0Y4123567123567<br>POWERX0X4X0X4123567123567 X0X4X0X4123567123567<br>**----- End of picture text -----**<br>
## **Extension units FX2NC**
The modular extension units of the FX2NC series can be used in combination with FX3GC or FX3UC series base units. They are available with 16 or 32 input/output points. For modules with 16 outputs it is possible to choose between relay and transistor output type.
- z Very compact dimensions
- z LEDs for indicating the input and output status
- z Removable terminal blocks for
- FX2NC-16EYR-T-DS and FX2NC-16EX-T-DS (interchangeable against optional spring terminal blocks)
- z Adapter modules and system cabling sets are optionally available for units with ribbon cable connectors (transistor output types)
|**Electrical data**|**Electrical data**|
|---|---|
|Integrated inputs/outputs|16<br>16<br>16<br>16<br>32<br>32|
|Power supply|All modular extension blocks are supplied bythe base unit.|
|**Inputs**||
|Integrated inputs|16<br>—<br>16<br>—<br>32<br>—|
|Input current X0→X7 / X10→∞|7/5<br>—<br>7/5<br>—<br>7/5<br>—|
|Min. current for logical 1<br>X0→X7/X10→∞<br>mA|mA 4.5/3.5<br>—<br>4.5/3.5<br>—<br>4.5/3.5<br>—|
|Max. current for logical 0<br>mA|mA 1.5<br>—<br>1.5<br>—<br>1.5<br>—|
|Isolation|Photocoupler isolation between input terminals and PCpower for all base units|
|Response time|For all extension units of the MELSEC FX2NC series: 10 ms(at time of shipment), partlyadjustable between 0 and 60 ms in 1 ms steps(REFF,FNC51 = 0–60 ms)|
|**Outputs**||
|Integrated outputs|—<br>16<br>—<br>16<br>—<br>32|
|Output type|—<br>Relay<br>—<br>Transistor<br>—<br>Transistor|
|Switchingvoltage(max.)|V Generallyfor relayversion: <240 V AC,<30 V DC;for transistor version: 5–30 V DC|
|Max. output<br>current<br>-per output<br>-pergroup*|A —<br>2<br>—<br>0.1/0.3a<br>—<br>0.1/0.3a|
||A —<br>4/8<br>—<br>0.8<br>—<br>0.8|
|Max. switching<br>power<br>- inductive load<br>VA<br>- lampload<br>W|VA —<br>80<br>—<br>2.4/7.2b<br>—<br>2.4/7.2b|
||W —<br>100<br>—<br>0.3/0.9c<br>—<br>0.3/0.9c|
|Response time<br>ms|ms —<br>10<br>—<br><0.2<br>—<br><0.2|
|Life of contacts(switchingtimes)|—<br>like base unit<br>—<br>—<br>—<br>—|
|**Mechanical data**||
|Connection type|Removable screw terminal blocks<br>Ribbon cable connector<br>Ribbon cable connector<br>Ribbon cable connector<br>Ribbon cable connector|
|Weight<br>k|kg 0.2<br>0.2<br>0.15<br>0.2<br>0.2<br>0.2|
|Dimensions (WxHxD)<br>mm|mm 20.2x90x89<br>24.2x90x89<br>14.6x90x87<br>14.6x90x87<br>26.2x90x87<br>26.2x90x87|
a 0.3 A for Y0 to Y1; 0.1 A all others b 7.2 W for Y0 to Y3; 2.4 W all others c 0.9 W for Y0 to Y3; 0.3 W all others
* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
Note: These modules can be combined with PLC base units of the FX3GC or FX3UC series!
32
Analog Modules
~~**4**~~
## ~~**Analog output modules**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX2N-2DA, FX2N-4DA, FX3U-4DA**
**==> picture [136 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX2N-2DA<br>an<br>FX3U-4DA<br>24 V<br>D/A<br>FX -4DA3U<br>**----- End of picture text -----**<br>
FX3U-/FX3UC controller to the analog signals required by the process. The module can output both current and voltage signals.
The analog output modules provide the user with 2 to 4 analog outputs. The modules convert digital values from the FX3G-/FX3GC-/FX3GE-/
|Analog channels<br>inputs<br>outputs|—<br>—<br>—|
|---|---|
||2<br>4<br>4|
|Analog output range|0–+10 V DC/<br>0–+5 V DC/<br>4–+20 mA<br>-10–+10 V DC/<br>0–+20 mA/<br>4–+20 mA<br>-10–+10 V DC/<br>0–+20 mA/<br>4–+20 mA|
|Resolution<br>voltage<br>current|2.5 mV(12 bit)<br>5 mV(10 bit)<br>0.32 mV(16 bit + sign)|
||4µA(12 bit)<br>20µA(11 bit + sign)<br>0.63µA(15 bit)|
|Fullscale overall accuracy|±1 %<br>±1 %<br>±0.3–0.5 %*|
|Power supply<br>5 V DC<br>24 V DC|30 mA(from base unit)<br>30 mA(from base unit)<br>—|
||85 mA(from base unit)<br>200 mA<br>160 mA|
|Related I/Opoints|8<br>8<br>8|
|Weight<br>kg|0.3<br>0.3<br>0.2|
|Dimensions(WxHxD)<br>mm|43x90x87<br>55x90x87<br>55x90x87|
* Dependent on the ambient temperature Note:
To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Analog input modules**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX2N-2AD, FX2N-4AD, FX3U-4AD, FX2N-8AD**
**==> picture [24 x 13] intentionally omitted <==**
**----- Start of picture text -----**<br>
2N-2AD<br>POWER<br>FX<br>**----- End of picture text -----**<br>
The analog input modules provide the user with 2 to 8 analog inputs.
The module converts analog process signals into digital values which are further processed by the FX3G/FX3GC/FX3GE/FX3U/FX3UC controller.
The actual values or mean values over several measurements may be output.
|Analog channels<br>inputs<br>outputs|2<br>4<br>4<br>4<br>8|
|---|---|
||—<br>—<br>—<br>—<br>—|
|Analog input range|0–+10 V DC/<br>0–+5 V DC/<br>0/4–+20 mA<br>-10–+10 V DC/<br>-20–+20 mA/<br>4–+20 mA<br>-10–+10 V DC/<br>-20–+20 mA/<br>4–+20 mA<br>-10–+10 V DC/<br>-20–+20 mA/<br>4–+20 mA<br>-10–+10 V DC/<br>-20–+20 mA/<br>4–+20 mA|
|Resolution<br>voltage<br>current|2.5 mV, 1.25 mV/<br>4 µA (12 bit)<br>5 mV<br>(11 bit + sign)<br>0.32 mV<br>(16 bit + sign)<br>0.32 mV<br>(16 bit + sign)<br>0.63 mV<br>(14 bit + sign)<br>20 µA<br>(10 bit + sign)<br>1.25 µA<br>(15 bit + sign)<br>1.25 µA<br>(15 bit + sign)<br>2.5 µA<br>(13 bit + sign)|
|Fullscale overall accuracy|±1 %<br>±1 %<br>±0.3–1 %*<br>±0.3–1 %*<br>±0.3–0.5 %*|
|Power supply<br>5 V DC<br>24 V DC|20 mA<br>(from base unit)<br>30 mA<br>(from base unit)<br>110 mA<br>(from base unit)<br>100 mA<br>(from base unit)<br>50 mA<br>(from base unit)|
||50 mA<br>(from base unit)<br>55 mA<br>90 mA<br>80 mA<br>80 mA|
|Related I/Opoints|8<br>8<br>8<br>8<br>8|
|Weight<br>kg|0.3<br>0.3<br>0.2<br>0.13<br>0.4|
|Dimensions (WxHxD)<br>mm|43x90x87<br>55x90x87<br>55x90x87<br>20.2x90x79<br>75x105x75|
*Dependent on the ambient temperature
Notes:
The FX2N-8AD can be configured to accept standard analog inputs as well as selected temperature inputs such as K, T or J type thermocouples. To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
33
Analog Modules
## ~~**Combined analog I/O modules**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX0N-3A, FX2N-5A**
~~**4**~~
**==> picture [117 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX0N-3A<br>FX2N-5A<br>24 V<br>AD / DA<br>FX -5A2N<br>**----- End of picture text -----**<br>
For the analog inputs it can be selected between current or voltage input signal. The FX0N-3A can only be connected to a FX3U or FX3UC base unit.
The analog input/output modules are available in two different models. They provide the user with 2 or 4 analog inputs and 1 analog output. They serve for conversion of analog process signals into digital values, and vice versa
|Analog channels<br>inputs<br>outputs|2<br>4|
|---|---|
||1<br>1|
|Input<br>(resolution)<br>voltage<br>current|0–+10 V (8 bit),<br>0–+5 V(8 bit)<br>-10–+10 V (15 bit + sign),<br>-100–+100 mV(11 bit + sign)|
||0/4–+20 mA (8 bit)<br>-20–+20 mA (14 bit + sign),<br>0/4–+20 mA(14 bit)|
|Output<br>(resolution)<br>voltage<br>current|0–+10 V (8 bit),<br>0–+5 V(8 bit)<br>-10–+10 V (12 bit)|
||4–+20 mA(8 bit)<br>0/4–+20 mA(10 bit)|
|Fullscale overall accuracy|±1 %<br>±0,3–1 %*|
|Power supply<br>5 V DC<br>24 V DC|30 mA(from base unit)<br>70 mA(from base unit)|
||90 mA(from base unit)<br>90 mA|
|Related I/Opoints|8<br>8|
|Weight<br>kg|0.2<br>0.3|
|Dimensions(WxHxD)<br>mm|43x90x87<br>55x90x87|
Note:
To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Analog temperature input modules**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX2N-4AD-TC, FX2N-4AD-PT, FX2N-2LC**
**==> picture [38 x 30] intentionally omitted <==**
**----- Start of picture text -----**<br>
2N<br>A / D<br>FX -4AD-TC<br>**----- End of picture text -----**<br>
The analog input module for thermocouples FX2N-4AD-TC is used for processing temperatures. It has 4 independent inputs for detecting signals from thermocouples of types J and K. The type of thermocouple can be chosen independently for each point.
The analog input module for Pt100 inputs FX2N-4AD-PT permits the connection of four Pt100 sensors to the FX3G/FX3GC/FX3GE/FX3U or FX3UC series controller.
The temperature control module FX2N-2LC reads and processes temperature signals from thermocouples and thermistors (Pt100 sensors). It is equipped with 2 separate input channels and 2 transistor output points (open collector). With these transistor outputs a temperature control by PID algorithm can be performed.
|Analoginputs|4(J or K type)<br>4(Pt100 sensors)<br>2points|
|---|---|
|Compensated temperature range<br>°C|-100–+600 (J type) /<br>-100–+1200(K type)<br>-100–+600<br>Thermocouple and<br>Pt100 sensor|
|Digital outputs|-1000–+6000 (J type)/<br>-1000–+12000(K type)<br>-1000–+6000<br>(12 bit conversion)<br>2 transistor output points|
|Resolution<br>°C|0.3(J type)/0,4(K type)<br>0.2–0.3<br>0.1 or 1|
|Fullscale overall accuracy|±0.5 % fullscale +1 °C<br>±1.0 % fullscale<br>±0.7 % (fullscale)<br>(±0.3 % (when ambient<br>temperature is 23 °C ±5 °C))|
|Power supply<br>5 V DC<br>24 V DC|40 mA(from base unit)<br>30 mA(from base unit)<br>70 mA(from base unit)|
||60 mA<br>50 mA<br>55 mA|
|Related I/Opoints|8<br>8<br>8|
|Weight<br>kg|0.3<br>0.3<br>0.3|
|Dimensions (WxHxD)<br>mm|55x90x87<br>55x90x87<br>55x90x87|
Note:
To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
34
Analog Modules
~~**4**~~
## ~~**Analog temperature input adapters**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX3U-4AD-TC-ADP, FX3U-4AD-PT-ADP, FX3U-4AD-PTW-ADP, FX3U-4AD-PNK-ADP**
The analog input adapter for thermocouples FX3U-4AD-TC-ADP is used for processing temperatures. It has 4 independent inputs for detecting signals from thermocouples of types thermometers to the PLC system. J and K.
The FX3U-4AD-PT-ADP, FX3U-4AD-PTW-ADP and FX3U-4AD-PNK-ADP analog input adapters enable the connection of up to four resistance
FX3U-4AD-TC-ADP
FX3U-4AD-PT-ADP
|Analog inputs<br>~~Po~~|4 (thermocouples,<br>J or K type)<br>4 (Pt100)<br>4 (Pt100)<br>4 (Pt1000 or Ni1000)<br>~~Po~~|
|---|---|
|Compensated temperature range<br>°C|-100–+600 (J)/<br>-100–+1000(K)<br>-50–+250<br>-100–+600<br>-50–+250 (Pt1000)/<br>-40–+110(Ni1000)|
|Digital outputs|-1000–+6000 (J)/<br>-1000–+10000(K)<br>-500–+2500<br>-1000–+6000<br>-500–+2500 (Pt1000)/<br>-400–+1100(Ni1000)|
|Resolution<br>°C|0.3(J)/0.4(K)<br>0.1<br>0.2–0.3<br>0.1|
|Fullscale overall accuracy|±0.5 %(fullscale)<br>±0.5–1.0 %(fullscale)*|
|Power supply<br>5 V DC<br>24 V DC|15 mA<br>(from base unit)<br>15 mA<br>(from base unit)<br>15 mA<br>(from base unit)<br>15 mA<br>(from base unit)|
||45 mA<br>50 mA<br>50 mA<br>50 mA|
|Related I/Opoints|0<br>0<br>0<br>0|
|Weight<br>kg|0.1<br>0.1<br>0.1<br>0.1|
|Dimensions(WxHxD)<br>mm|17.6x90(106)x89.5|
*Dependent on the ambient temperature
Note:
When connecting the analog adapters to a FX3G, FX3S or FX3U base unit, a communications adapter is required. A direct connection without adapter is possible if these modules are connected to a FX3GC, FX3GE or FX3UC base unit.
## ~~**Analog I/O adapters**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX3U-4AD-ADP, FX3U-4DA-ADP, FX3U-3A-ADP**
The analog input adapter for thermocouples FX3U-4AD-TC-ADP is mounted on the left side of the base unit and extends a controller of the FX3 series with up to 4 analog inputs.
The analog input/output module FX3U-3A-ADP provides the user with two analog inputs and one analog output.
The analog output adapter FX3U-4DA-ADP is mounted on the left side of a FX3 series base unit and provides four analog outputs.
FX3U-4AD-ADP
FX3U-4DA-ADP
|Analog channels<br>inputs<br>outputs|4<br>—<br>2|
|---|---|
||—<br>4<br>1|
|Analogrange|0–+10 V DC,4–+20 mA<br>0–+10 V DC,4–+20 mA<br>0–+10 V CC,4–+20mA|
|Resolution|2.5 mV/10µA(12 bit/11 bit)<br>2.5 mV/4µA(12 bit)<br>2.5 mV/4μA(12 bit)|
|Overall accuracy|±0.5 % */±1 %<br>±0.5 % */±1 %<br>±0.5–1 %*|
|Power supply<br>5 V DC<br>24 V DC|15 mA(from base unit)<br>15 mA(from base unit)<br>20 mA(from base unit)|
||40 mA<br>150 mA<br>90 mA|
|Related I/Opoints|0<br>0<br>0|
|Weight<br>kg|0.1<br>0.1<br>0.1|
|Dimensions (WxHxD)<br>mm|17.6x90(106)x89.5<br>17.6x90(106)x89.5<br>17.6x90x89.5|
*Dependent on the ambient temperature and signal quality
Note:
When connecting the analog adapters to a FX3G, FX3S or FX3U base unit, a communications adapter is required. A direct connection without adapter is possible if these modules are connected to a FX3GC, FX3GE or FX3UC base unit.
35
Temperature Control/Data Logger
~~**4** _~~
## ~~**Temperature control module**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Temperature control module**
**==> picture [63 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX -4LC<br>24 V<br>OUT1<br>OUT2<br>OUT3<br>OUT4<br>3U<br>**----- End of picture text -----**<br>
The temperature control module FX3U-4LC is equipped with four temperature input points and four transistor (open collector) output points. It is used to read temperature signals from thermocouples and Pt100 sensors, and performs PID output control.
The proportional band, the integral time and the derivative time can be easily set by auto tuning. The channels are isolated against each other. Self-diagnosis functions are provided, and the disconnection of heaters can be detected by current detection (CT).
|Analoginputs|4(Thermocouple and Pt100 sensors)|
|---|---|
|Compensated temperature range<br>°C|-200–+2300|
|Digital outputs|4 NPN transistor open collector outputpoints|
|Resolution<br>°C|0.1 or 1|
|Fullscale overall accuracy|±0.3–0.7 %(fullscale,dependent on the ambient temperature)|
|Power supply<br>5 V DC<br>24 V DC|160 mA(from base unit)|
||50 mA|
|Related I/Opoints|8|
|Dimensions (WxHxD)<br>mm|90x90x86|
Note:
To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Data logger module**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Data logger module**
**==> picture [48 x 22] intentionally omitted <==**
**----- Start of picture text -----**<br>
POWER CF CARDFULL ACCESSON<br>BUFFER ACCESS<br>ERR. SLOT OFF<br>FX3U-CF-ADP<br>**----- End of picture text -----**<br>
The FX3U-CF-ADP is a general purpose data logAnother usage is the storage of bigger recipe ging adapter. The difference to other available data. A CompactFlash® memory card up to 2GB logging units is that the PLC main unit controls can be used. Six applied instructions allow all the data logging based on user requirements, kinds of data writing, manipulation or reade.g. periodical or even based. For tracing a ing, making this adapter the optimum solution timestamp is automatically added to all data towards customer requirements. storages, that eases alarm and other time critical logging.
|Data access method<br>~~ee~~|Controlled bythe main unit,nopollingfrom the loggingunitpossible.<br>~~ee~~|
|---|---|
|Connectable units|A maximum of one FX3U-CF-ADP can be connectedper PLC.|
|Time stampfunction|The real time clock data of the base unit is used.|
|Recommended storage media|CompactFlash® memorycard(GT05-MEM-256MC,-512MC,-1GC,-2GC)|
|Max. file size|512 MB|
|File format|CSV|
|Max. numbers of files|63(Plus one FIFO file.)|
|FIFO function|Onepattern(The file namegets automatically generated.)|
|Power supply<br>24 V DC|130 mA|
|Related I/Opoints<br>kg|0|
|Dimensions (WxHxD)<br>mm|45x90x89.5|
36
High Speed Counter
~~**4**~~
## ~~**High-speed counter modules**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX2N-1HC, FX2NC-1HC, FX3U-2HC**
**==> picture [90 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
{T=<br>FX -1HC2N<br>**----- End of picture text -----**<br>
The two integrated transistor outputs can be switched independently of one another by means of internal comparison functions. Hence, simple positioning tasks can also be realized economically. In addition, the modules can be used as a ring counter.
In addition to the internal high-speed MELSEC FX counters, the high-speed counter modules FX2N-1HC, FX2NC-1HC and FX3U-2HC provide the user with an external counter. It counts 1- or 2-phase pulses up to a frequency of 200 kHz. The counting range covers either 16 or 32 bit.
|Counter inputs|2(1phase)or 1(2phase)<br>2(1phase)or 1(2phase)|2(1phase)or 1(2phase)|
|---|---|---|
|Max. countingfrequency<br>kHz|50<br>50|200/100/50|
|Signal level|5,12,24 V DC/7 mA<br>5,12,24 V DC/7 mA|5,12,24 V DC|
|Input format<br>bit|16,32<br>16,32|—|
|Type of counter|Up/down counter,ringcounter Up/down counter,ringcounter|Up/down counter,ringcounter|
|Counting range<br>16 bit<br>32 bit|0–65535<br>0–65535|0–65535|
||-2147483648–+2147483647<br>-2147483648–+2147483647|-2147483648–+2147483647|
|Output type|2 x transistor(5–24 V DC;0.5 A) 2 x transistor(5–24 V DC;0.5 A)|2 x transistor(5–24 V DC;0.5 A)|
|Power supply<br>5 V DC<br>24 V DC|90 mA(from base unit)<br>90 mA(from base unit)|24 mA(from base unit)|
||—<br>—|—|
|Related I/Opoints|8<br>8|8|
|Weight<br>kg|0.3<br>0.13|0.08|
|Dimensions(WxHxD)<br>mm|55x90x87<br>20.2x90x89|55x90x87|
*The FX2NC 1HC can only be connected to a FX3UC base unit.
## ~~**High-speed counter adapters**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **FX3U-4HSX-ADP, FX3U-2HSY-ADP**
These adapter modules allow direct processing of positioning application data.
FX3U-2HSY-ADP delivers 2 channels of pulse train outputs up to 200 kHz.
The FX3U-4HSX-ADP provide high speed counter inputs up to 200 kHz while the
FX3U-4HSX-ADP
FX3U-2HSY-ADP
|Maximum connectivity|2<br>2|
|---|---|
|Counter<br>inputs<br>outputs|4<br>—|
||—<br>2|
|Max. counting<br>frequency<br>inputs<br>kHz<br>outputs<br>kHz|1 ch 1 input or<br>1 ch 2 inputs: 200<br>2 ch 2 inputs: 100<br>—|
||—<br>200|
|Input format|Differential line receiver (AM26C32 is suitable)<br>Photocoupler isolation on inputs<br>—|
|Output format|—<br>Differential line driver (AM26C31 is suitable)<br>Normal rotation pulse train, reverse pulse<br>train orpulse train + one|
|Maximum cable length<br>m|10<br>10|
|Inputpotential|5 V DC<br>—|
|Output load|—<br>less than 25 mA|
|Power supply<br>5 V DC<br>24 V DC|30 mA(from base unit)<br>30 mA(from base unit)|
||30 mA(from base unit)<br>60 mA(from base unit)|
|Related I/Opoints|0<br>0|
|Weight<br>kg|0.08<br>0.08|
|Dimensions(WxHxD)<br>mm|17.6x90(106)x89.5<br>17.6x90(106)x89.5|
Note:
The adapters FX3U-m-ADP can only be used with the FX3U and they require a function extension board.
37
Positioning Modules
~~**4**~~
## ~~**Single-axis positioning modules**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX3U-1PG, FX2N-10PG**
**==> picture [51 x 27] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 8<br>FX<br>POWER<br>ERROR<br>START<br>2N-10PG DOGX0X1øAøB PGOFPRPCLR<br>**----- End of picture text -----**<br>
The positioning modules FX3U-1PG and FX2N-10PG are extremely efficient single-axis positioning modules for controlling either step drives or servo drives (by external regulator) with a pulse chain. They are very suitable for achieving accurate positioning in combination
with the MELSEC FX series. The configuration and allocation of the position data are carried out directly via the PLC program. A very wide range of manual and automatic functions are available to the user.
|Accessible axes|1<br>1|
|---|---|
|Output frequency<br>Impulse/s|10–200 000<br>1–1 000 000|
|Signal level for digital inputs|24 V DC/40 mA<br>5 V DC/100 mA;<br>24 V DC/70 mA|
|Power supply<br>5 V DC<br>24 V DC|150 mA(from base unit)<br>120 mA(from base unit)|
||—<br>—|
|Related I/Opoints|8<br>8|
|Weight<br>kg|0.3<br>0.2|
|Dimensions(WxHxD)<br>mm|43x90x87<br>43x90x87|
## ~~**Positioning module for SSCNET**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **SSCNETIII-Modul FX3U-20SSC-H**
**==> picture [37 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
© 000 Syieor<br>**----- End of picture text -----**<br>
The SSCNET module FX3U-20SSC-H can be used in combination with a FX3U or FX3UC programmable controller to achieve a cost effective solution for high precision, high speed positioning. The plug-and-play fiber optic SSCNET cabling reduces setup time and increases control distance for positioning operations in a wide range of applications.
Servo parameters and positioning information for the FX3U-20SSC-H are easily set up with an FX3U/FX3UC base unit and a personal computer. For parameter setting, monitoring and testing the easy programming software FX Configurator-FP is available.
|**Specifications**||**FX3U-20SSC-H**|
|---|---|---|
|Accessible axes||2(independent or interpolation)|
|Output frequency||1 Hz to 50 MHz|
|Pulse output format||SSCNETIII(servo bus)|
|Communications speed||50 Mbps|
|Startingtime|ms|1.6(+1.7 SSCNET cycle time)|
|Max. to PLC connectable modules||Upto 8 can be connected to the FX3U PLC|
|Status displays||Power,module status,axis status,error|
|Power supply|5 V DC<br>24 V DC|100 mA<br>—|
|Related I/Opoints||8|
|Weight|kg|0.3|
|Dimensions (WxHxD)|mm|55x90x87|
|**Order information**|Art. no.|168914|
Note:
The FX3U-20SSC-H can be used in combination with a FX3U or FX3UC base unit only. Please refer to the Mitsubishi Electric MELSERVO catalog for suitable servo motors and amplifiers.
38
Network Modules
~~**4**~~
## ~~**Network modules for CC-Link**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **CC-Link master module FX3U-16CCL-M**
**==> picture [83 x 84] intentionally omitted <==**
**----- Start of picture text -----**<br>
il<br>POWER (om)<br>FX3U-16CCL-M<br>RUN<br>ERR.<br>L RUN<br>L ERR.<br>SD<br>RD<br>**----- End of picture text -----**<br>
The setting of all modules within the network is handled directly via the master module.
The CC-Link network enables the controlling and monitoring of decentralized I/O modules at the machine.
The maximum communications distance is 1200 m without repeater.
The CC-Link master module FX3U-16CCL-M is a special extension module, which assigns an FX3G, FX3GC, FX3GE, FX3U or FX3UC series PLC as the master station of a CC-Link system.
|Module type|Master station|
|---|---|
|Link points per station<br>I/Opoints<br>register|32|
||8|
|Max. number of I/Opoints|FX3G/FX3GC/FX3GE: 32 x nbr. of stations ≤128 FX3U/FX3UC: 32 x nbr. of stations ≤256*|
|Number of connectable modules|max. 16|
|Power supply<br>5 V DC<br>24 V DC|—|
||240 mA|
|Related I/Opoints|8|
|Weight<br>kg|0.4|
|Dimensions(WxHxD)<br>mm|55x90x87|
*Total of I/O points in base unit and extension units within the CC-Link network ≤384. Note:
To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric.
## **FX3U-64CCL interface module**
The FX3U-64CCL CC-Link interface module is available for FX3G, FX3GC, FX3GE, FX3U or FX3UC series main units and enables CC-Link V2
functionality, for example expanded cyclic transmission which facilitates handling of multiple data processes.
|Module type|Intelligent device station|
|---|---|
|Link points per station<br>I/Opoints<br>register|128(Occupying1 station with Octuple expanded cyclic setting)|
||32(Occupying1 station with Octuple expanded cyclic setting)|
|Max. transmission speed|10 Mbps|
|Related I/Opoints|8|
|Power supply<br>24 V DC|24 V DC/220 mA|
|Weight<br>kg|0.3|
|Dimensions(WxHxD)<br>mm|55x90x87|
Note:
When attaching the FX3U-64CCL to a FX3UC/FX3GC base unit, the FX2NC-CNV-IF interface converter or the FX3UC-1PS-5V power supply unit is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric.
39
Network Modules
~~**4**~~
## ~~**Network module for CC-Link**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **CC-Link communication module FX2N-32CCL**
**==> picture [40 x 29] intentionally omitted <==**
**----- Start of picture text -----**<br>
LRUN • LERR • RD • SD<br>FX2N-32CCL<br>**----- End of picture text -----**<br>
The communication module FX2N-32CCL enables the user to connect to the CC-Link
network with a superior PLC system as master CPU. This gives him access to the network of all MELSEC PLC systems and frequency inverters and to additional products from other suppliers.
Thus the network is expandable via the digital inputs/outputs of the FX modules to a maximum of 256 I/Os.
The buffer memory of the FX2N-32CCL is read and written by FROM/TO instructions.
The connection is to the extension bus on the right side of the controller.
|Module type|Remote station|
|---|---|
|Link points per station<br>I/Opoints <br>register|32|
||8|
|Max. number of I/Opoints|—|
|Number of connectable modules|—|
|Power supply<br>5 V DC<br>24 V DC|max. 130 mA(from base unit)|
||50 mA|
|Related I/Opoints|8|
|Weight<br>kg|0.3|
|Dimensions(WxHxD)<br>mm|43x90x87|
Notes:
To connect this module to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric.
## ~~**Network module for Ethernet**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Ethernet communications module FX3U-ENET**
**==> picture [108 x 122] intentionally omitted <==**
**----- Start of picture text -----**<br>
EN<br>a<br>FX3U-ENET<br>10BASE-T/100BASE-TX<br>RUN<br>INIT.<br>100M<br>SD<br>RD<br>ERR.<br>COM.ERR.<br>C1<br>C2<br>C3<br>C5<br>C6<br>C7<br>C8<br>POWER<br>C4<br>**----- End of picture text -----**<br>
addition to supporting full program UP/DOWN load as well as comprehensive monitoring support. The module also supports Peer to Peer connection and MC Protocol. It is easily set-up with the FX Configurator-EN software.
The FX3U-ENET communications module provides the FX3G, FX3GE, FX3U or FX3UC with a direct connection on to an Ethernet network. With the FX3U-ENET installed an FX3G/FX3GE/ FX3U/FX3UC PLC can exchange data quickly and easily with process visualization systems in
|**Specifications**||**FX3U-ENET/FX3U-ENET-P502**|
|---|---|---|
|Protocol||TCP/IP,UDP|
|Communication mode||Full-duplex/half-duplex|
|No. of simultaneous open connections||8|
|Fixed buffer communication||1023 word x 8|
|Communication with mail server||SMTP,POP3|
|Interface||IEEE802.3u(100BaseTX),IEEE802.3(10BaseT)|
|Connector||RJ45|
|Max. transfer rate||100 Mbits/s,10 Mbit/s|
|Max. segment length|m|100|
|Cable||CAT5 STP or 3 STP|
|Power supply|5 V DC<br>24 V DC|—<br>240 mA(from base unit)|
|Related I/Opoints||8|
|Weight|kg|0.3|
|Dimensions (WxHxD)|mm|55x90x87|
||||
|**Order information**|Art. no.|166086/225142|
Note:
To connect this module to a FX3UC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
40
Network Modules
~~**4**~~
## ~~**Network module for Ethernet**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Ethernet communications adapter FX3U-ENET-ADP**
The FX3U-ENET-ADP communications adapter is an Ethernet interface with 10BASE-T specifications for the FX3G, FX3GC, FX3S or FX3U series.
The FX3U-ENET-ADP enables upload, download, monitor and test sequence of programs via Ethernet from a personal computer (GX Works2 or MX Components have to be installed).
|**Specifications**||**FX3U-ENET-ADP**|
|---|---|---|
|Protocol||TCP/IP|
|No. of simultaneous open connections||1|
|Interface||IEEE802.3u(100BaseTX),IEEE802.3(10BaseT)|
|Connector||RJ45(to Ethernet),3 screw terminals(toground)|
|Max. transfer rate<br>Cable<br>Power supply|5 V DC<br>24 V DC|10 Mbit/s,100 Mbit/s<br>CAT5 STP or 3 STP<br>30 mA(from base unit)<br>—|
|Related I/Opoints||0|
|Weight|kg|0.1|
|Dimensions (WxHxD)|mm|23x90(106)x81.5|
|**Order information**|Art. no.|248844|
Note:
This module can be connected directly (without adapter) to a base unit of the FX3GC or FX3UC series. To connect this module to a FX3G, FX3S or FX3U base unit, an adapter is required.
## ~~**Network module for Profibus DP**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Master modul FX3U-64DP-M**
**==> picture [41 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-64DP-M<br>RUN<br>TOKEN<br>FROM/TO<br>ERROR<br>POWER<br>**----- End of picture text -----**<br>
The FX3U-64DP-M Profibus DP master module enables you to integrate a MELSEC FX3U or FX3UC PLC system as a class 1 master of a Profibus DP network.
This interface module provides your FX3U/ FX3UC base unit with an intelligent Profibus DP link for the implementation of decentralised control tasks.
The FX3U Profibus DP master provides comprehensive data and alarm processing to the Profibus DP V1 standard. It is easily set up with the GX Configurator-DP software.
|Module type|Master station|
|---|---|
|Transmission type|Bus network|
|Transmission data|32 byte/slave (normal service mode)<br>244 byte/slave(extended service mode)|
|Interface|Profibus DP(with 9pole D-SUB connector)|
|Max. number of masterper configuration|max. 1|
|Repeaters|3|
|Max. number of slaves|64|
|Communications speed|Profibus standard|
|Communications distance<br>m|max. 1200(depends on communication speed)|
|Communication cable|Profibus cable with 9-pin D-SUB connector|
|Power supply<br>5 V DC<br>24 V DC|—|
||max. 155 mA(from base unit)|
|Related I/Opoints|8|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|43x90x87|
Note:
The FX3U-64DP-M can be used in combination with a FX3U or FX3UC base unit only. To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
41
Network Modules
~~**4**~~
## ~~**Network module for Profibus DP**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX3U-32DP Profibus DP slave module**
The FX3U-32DP Profibus DP slave module is available for FX3G, FX3GC, FX3GE, FX3U and FX3UC series main units and allows the attached FX main unit to function as a slave station on a Profibus DP-V1 network.
Profibus DP-V1 functionality supports extensive alarm processing and messaging on top of standard cyclic data exchange.
|Module type|Slave station|
|---|---|
|Transmission type|Bus network|
|Transmission data|max. 144 bytes|
|Interface|9-pin D-SUB for Profibus DP|
|Max. number of slave stationsper configuration|8|
|Communication speed 5 V DC|max. 12 Mbit/s|
|Communication<br>distance<br>24 V DC|max. 1200 (depends on communication speed)|
|Communication cable|Profibus cable with 9-pin D-SUB connector|
|Related I/Opoints|8|
|Power supply|24 V DC/145 mA(from base unit)|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|43x90x89|
Note: To connect a FX3U-32DP to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Remote I/O station for Profibus DP**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Remote I/O station FX2N-32DP-IF**
The remote I/O station FX2N-32DP-IF forms an extremely compact communication unit and provides a connection of I/O modules with up to 256 I/O points and/or up to 8 special function modules as an alternative.
The FX2N-32DP-IF includes a 240 V power supply unit and a 24 V service voltage terminal, e.g. for analog modules. The FX2N-32DP-IF-D is supplied with 24 V DC.
**==> picture [449 x 97] intentionally omitted <==**
**----- Start of picture text -----**<br>
to 256 I/O points and/or up to 8 special function supplied with 24 V DC.<br>modules as an alternative. Profibus data such as the baud rate or I/O data<br>It features an entire electrical isolation of the can be monitored directly with the program-<br>Profibus DP connector and of the sensor/actu- ming software or on the hand-held program-<br>ator circuits. ming units FX-10P/FX-20P/FX-30P. This facilitates<br>an easy error diagnosis directly on the remote<br>|=z: I/O station.<br>J Specifications FX2N-32DP-IF FX2N-32DP-IF-D<br>FX2N-32DP-IF<br>ON<br>OFF<br>MITSUBISHI<br>RUN<br>STOP<br>COM 24 +<br>L N<br>POWER<br>RUN<br>BF<br>DIA<br>64 32 16 8 4 2 1<br>**----- End of picture text -----**<br>
Profibus data such as the baud rate or I/O data can be monitored directly with the programming software or on the hand-held programming units FX-10P/FX-20P/FX-30P. This facilitates an easy error diagnosis directly on the remote I/O station.
|Power supply|100–240 V AC<br>(+10 %/-15 %)50/60 Hz<br>24 V DC<br>(+20 %/-30 %)|
|---|---|
|Power consumption|30 VA<br>14 W|
|Internal current consumption|5 V DC/max. 220 mA (from base unit),<br>24 V DC/500 mA<br>5 V DC/max. 220 mA (from base unit)|
|Interface (connectors)|9-pin D-SUB for Profibus DP,<br>8-pin Mini-DIN for PC orprogrammingunit FX-10P/FX-20P/FX-30P|
|Communication<br>speed<br>distance<br>1200 m<br>kbps <br>1000 m<br>kbps <br>400 m<br>kbps <br>200 m<br>kbps <br>100 m<br>kbps||
||9.6/19.2/45.45/93.75|
||187.5|
||500|
||1500|
||3000/6000/12000|
|Communication distance<br>m|max. 1200(depends on communication speed)|
|Communication cable|Profibus cable with 9-pin D-SUB connector|
|Max. number of controllable I/Opoints|256|
|Weight<br>kg|0.4|
|Dimensions (WxHxD)<br>mm|75x98x87|
42
Network Modules
~~**4**~~
## ~~**Network module for DeviceNet**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **DeviceNet slave module FX2N-64DNET**
The DeviceNet slave module FX2N-64DNET can be used to connect FX3G, FX3GC, FX3GE and FX3U programmable controllers to a DeviceNet network.
The FX2N-64DNET can communicate to the master by the master/slave communication (using the master/slave I/O connection), and
to other nodes supporting the UCMM connection by client/server communication (using the UCMM connection).
The communication between the programmable controller and the internal buffer memory of the FX2N-64DNET is handled by FROM/TO instructions.
|Module type|Slave(group2)|
|---|---|
|Node type|G2 server|
|Station numbers|0–63points|
|Supported communication speeds<br>kbps|125/250/500|
|Communication<br>data (open con-<br>nection)<br>Master/<br>slave<br>no. of connections<br>transfer time-out<br>UCMM<br>client/server<br>no. of connections<br>data length|1 connection(group2)|
||2,000 ms(ACK time-out)|
||63/63(group1,3)|
||max. 64 bytesper connection|
|Communication data<br>(I/O connection)<br>type<br>data length|Polling,cyclic,change of state|
||max. 64 bytes(fragmentation ispossible)|
|Module ID code|K 7090|
|Status displays|Power,module status,network status|
|Related I/Opoints|8|
|Power supply<br>5 V DC<br>24 V DC|120 mA|
||50 mA|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|43x90x87|
## ~~**Network module for CANopen**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **CANopen master module FX3U-CAN**
**==> picture [48 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
cANoper® g<br>owes<br>t<br>N<br>RUN<br>FROM/TO<br>Tx/Rx<br>ERROR<br>POWER<br>AN_GND<br>AN_L<br>AN_SHLD<br>AN_H<br>AN_V+<br>FX3U-CAN<br>**----- End of picture text -----**<br>
The FX3U-CAN communications module makes it possible to connect a FX3G, FX3GC, FX3GE, FX3U or FX3UC PLC to an existing CANopen network.
Up to 320 process data objects (PDOs) can be sended or received. The CANopen Profile CiA 405 V2.0 and CiA 417 V2.0 are supported.
Communication with the module’s memory In addition to real-time capabilities and highbuffer is performed with simple FROM/TO speed data transfer at rates of up to 1 Mbit/s the instructions. CANopen module also shines with high transfer reliability and simple network configuration.
|Module type<br>~~ee~~|CANopen master<br>~~ee~~|
|---|---|
|CAN standard|ISO 11898/1993|
|CANopen standard byCiA|DS-301 version 3.0|
|Additional CANopen features|NMT, Guarding, and Guarding request based on DS-302 V2.0.<br>network variables based on DS-405 V1.0|
|Max. number of modules that can be connected to the network|30 without repeater;127 with repeater|
|Station numbers|1–127|
|Supported communication speeds<br>kbps|10,20,50,125,250,500,800,1000|
|Status displays|RUN,Error,Power,Network status|
|Power supply<br>5 V DC<br>24 V DC|290 mA|
||—|
|Related I/Opoints|8|
|Weight<br>kg|0.2|
|Dimensions (WxHxD)<br>mm|43x90x88.7|
Note:
To connect this module to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
43
Network Modules/Communications Modules
~~**4**~~
## ~~**Network module for J1939**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Network module for J1939**
Up to 75 standard messages and 4 extension messages can be sent and received.
The FX3U-J1939 communication module allows Up to 75 standard messages and 4 extension the connection of FX3G/FX3U/FX3UC series messages can be sent and received. PLCs to a J1939 network. J1939 is a CAN based The FX3U-J1939 is compatible with CAN Layer 2 protocol used for communication with motors, communication. In this mode, a FX3U-J1939 can generators and compressors. send and receive up to 42 messages on a CAN In a J1939 network are no master or slave network. stations. All nodes may receive each others’ Ak i messages. Standard messages contain up to 8 bytes of data, extended messages contain up to 250 bytes of data. ~~a~~ **Specifications FX3U-J1939**
|**Specificationspecificationsecifications**<br>**FX3U-J1939**<br>~~a~~|
|---|
|Communication standard version<br>J1939<br>~~a~~|
|Network node size<br>J1939: 2–30<br>NMEA2000®: 2–50|
|Communication method<br>Cyclic,acyclic or request driven(user configurable)|
|CAN layer-2 communication<br>Send and receive|
|Max. cable length<br>m 5000|
|Baud rates<br>kbit/s 10,20,50,100,125,250,500,800,1000|
|Power supply<br>24 V DC/110 mA(from base unit)|
|Weight<br>kg 0.2|
|Dimensions (WxHxD)<br>mm 43x90x95|
|**Order information**<br>Art. no. 254276|
Note:
To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
## ~~**Modbus & serial communication special adapter**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Active data module (RS485)**
The addition of an active data interface module permits active communication between the PLC and surrounding devices.
FX3U-485ADP-MB also supports Modbus RTU and Modbus ASCII.
With RS485 communication can be configured as either 1:N multidrop, parallel link or peer to peer operation.
|Interface<br>~~ee~~|RS485;Modbus RS485<br>~~ee~~|
|---|---|
|Communication speed*<br>kbps <br>~~ee~~|0.3–19.2<br>~~ee~~|
|Max. communication distance<br>m|500|
|Power supply<br>5 V DC<br>24 V DC|20 mA(from base unit)|
||—|
|Related I/Opoints|0|
|Dimensions (WxHxD)<br>mm|17.6x90(106)x74|
* Speed depends on communication method (Parallel link, N:N Network, No protocol, Dedicated protocol etc.)
Note:
This adapter module can be connected directly (without special adapter) to a base unit of the FX3GC, FX3GE or FX3UC series. To connect this adapter module to a FX3G, FX3S or FX3U base unit, an adapter is required.
44
Communications Modules
~~**4**~~
## ~~**Interface module**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Active data interface module FX3U-232ADP-MB**
The additional active data interface module permits active communication between the PLC and surrounding RS232C peripherals. All device information can be sent or received via these interfaces.
The connection is to the communications bus on the left side of the controller. The internal serial RS422 interface is also fully available. The FX3U-232ADP-MB can also be used for communication via MODBUS.
The module is suitable for the connection of printers, bar code readers, PCs and other PLC systems. The communication is handled by the PLC program using the RS instruction.
|Interface|RS232C with 9pole D-SUB connector(photocoupler isolation)|
|---|---|
|Communication speed*<br>kbps|0.3–115.2|
|Power supply<br>5 V DC<br>24 V DC|30 mA(from base unit)|
||—|
|Related I/Opoints|0|
|Weight<br>kg|0.08|
|Dimensions (WxHxD)<br>mm|17.6x90(106)x81.5|
* Speed depends on communication method (No protocol, Dedicated protocol, Protocol for programming tool) Note:
This module can be connected directly (without adapter) to a base unit of the FX3GC, FX3GE or FX3UC series. To connect this module to a FX3G, FX3S or FX3U base unit, an adapter is required.
## ~~**Interface module**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Interface module FX2N-232IF**
The interface module FX2N-232IF provides an RS232C interface for serial data communications with the MELSEC FX3U and FX3UC.
Communication with PCs, printers, modems, barcode readers etc. is handled by the PLC program.
The send and receive data are stored in the FX2N-232IF’s own buffer memory.
|Interface|RS232C with 9pole D-SUB connector(photocoupler isolation)|
|---|---|
|Communication speed<br>kbps|0.3–19.2|
|Communication distance<br>m|max. 15|
|Communication cable|Shielded cable|
|Communication mode|Full duplex|
|Protocols|Nonprotocol mode/start stopsynchronisation|
|Send and receive buffer|512 byte each|
|Format|7 or 8 bits, paritynone/even/odd,stopbits: 1 or 2|
|Power supply<br>5 V DC<br>24 V DC|40 mA(from base unit)|
||80 mA|
|Related I/Opoints|8|
|Weight<br>kg|0.3|
|Dimensions (WxHxD)<br>mm|55x90x87|
Note:
To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
45
Extension Adapters
## ~~�~~ ~~**[Digital extension adapter boards]**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Extension adapters FX3G-4EX-BD, FX3G-2EYT-BD**
~~**4**~~
FX3G-4EX-BD
FX3G-2EYT-BD
## ~~�~~ ~~**[Analog adapter boards]**~~
The extension adapters for the FX3G series are available with 4 inputs or 2 outputs.
These adapters are especially advantageous when only few additional I/Os are required and there is not enough room for an adjacent module to be installed.
They are installed directly in the controller of the FX3S or FX3G series and therefore do not require any additional installation space.
**==> picture [337 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications FX3G-4EX-BD FX3G-2EYT-BD<br>Applicable for Base units FX3S/FX3G<br>Integrated inputs/outputs 4 4<br>Power supply From base unit<br>Integrated inputs 4 —<br>Integrated outputs — 2<br>voltage 24 V DC (+20 %/-15 %)<br>Input level<br>current 5 mA (24 V DC)<br>Output type — Transistor<br>Max. switching voltage V — 5–30 V DC<br>Weight kg 0.02 0.02<br>Dimensions (WxHxD) mm 35x51.2x29.2 35x51.2x29.2<br>Order information Art. no. 271700 271701<br>**----- End of picture text -----**<br>
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** þ~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Analog adapter boards FX3G-1DA-BD and FX3G-2AD-BD**
FX3G-2AD-BD
The analog input adapter board FX3G-2ADBD provides the user with 2 analog inputs. The board converts analog process signals into digital values which are further processed by the MELSEC FX3S/FX3G/FX3GE controller.
The analog adapter FX3G-1DA-BD provides the user with 1 analog output. This module converts digital values from the FX3S/FX3G/FX3GE controller to the analog signals required by the process.
**==> picture [338 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
Specifications FX3G-2AD-BD FX3G-1DA-BD<br>Applicable for Base units FX3S/FX3G/FX3GE Base units FX3S/FX3G/FX3GE<br>Power supply From base unit From base unit<br>inputs 2 —<br>Analog channels outputs — 1<br>Analog input range 0–+10 V DC/4–+20 mA 0–+10 V DC/4–+20 mA<br>voltage input kΩ198.7 —<br>Input resistance current input Ω250 —<br>voltage output kΩ— 2–1,000<br>External load<br>current output Ω— <500<br>Resolution 2.5 mV (12 bit)/8 µA (11 bit) 2.5 mV (12 bit)/8 µA (11 bit)<br>Fullscale overall accuracy ±1 % ±1 %<br>analog → digital 180 µs (1 program cycle) —<br>Conversion speed digital → analog — 60 µs (1 program cycle)<br>Related I/O points 0 0<br>Weight kg 0.02 0.02<br>Dimensions (WxHxD) mm 35x51.2x29.2 35x51.2x29.2<br>Order information Art. no. 221265 221266<br>**----- End of picture text -----**<br>
FX3G-1DA-BD
46
Extension Adapters
~~**4**~~
## ~~**Analog setpoint adapter board**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** þ~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Analog setpoint adapter FX3G-8AV-BD**
The FX3G-8AV-BD analog setpoint adapter enables the user to set 8 analog setpoint values. The analog values of the potentiometers are read into the controller and used as default setpoint values for timers, counters and data registers by the user’s PLC programs.
Setpoint value polling and the definition of the potentiometer scales are performed in the PLC program using the dedicated instructions VRRD/ VRSC (FNC85/86).
The analog setpoint adapter is installed in the expansion slot of the FX3S/FX3G resp. FX3GE CPU. No additional power supply is required for operation.
Connector side
~~ee~~ **Specifications FX3G-8AV-BD** Applicable for Base units FX3S/FX3G/FX3GE Power supply From base unit Adjusting range 8 Bit Related I/O points 0 Potentiometer evaluation Via application instruction from the PLC CPU (FNC 85/86) Weight kg 0.02 Dimensions (WxHxD) mm 35x51.2x12 **Order information** Art. no. 221267
## ~~**Communications adapter board**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Adapter board FX3U-USB-BD**
This adapter board allows direct USB 2.0 connection to the front of the FX3U PLC for program maintenance.
**Specifications FX3U-USB-BD** Applicable for Base units FX3U Power supply 5 V DC (from base unit) Weight kg 0.02 Dimensions (WxHxD) mm 19.6x46.1x53.5 **Order information** Art. no. 165284
## ~~**Expansion adapters**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Expansion adapters FX3G-CNV-ADP, FX3S-CNV-ADP, FX3U-CNV-BD**
The below listed expansion adapters enable the connection of the adapter modules
FXmm-mmmADP on the left hand side of the FX3S, FX3G and FX3U base units.
|**Specifications**<br>**FX3G-CNV-ADP**<br>**FX3S-CNV-ADP**<br>**FX3U-CNV-BD**|
|---|
|Applicable for<br>Base units FX3G<br>Base units FX3S<br>Base units FX3U|
|Weight<br>kg 0.1<br>0.1<br>0.01|
|Dimensions (WxHxD)<br>mm 90x14.6x86<br>90x14.6x74<br>19.6x46.1x53.5|
||
|**Order information**<br>Art. no. 221268<br>267132<br>165285|
**==> picture [52 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-CNV-ADP<br>**----- End of picture text -----**<br>
47
Interface Adapters
## ~~**Interface adapters**~~
**==> picture [45 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-232-BD<br>**----- End of picture text -----**<br>
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Interface adapters FX3G-232-BD, FX3U-232-BD**
The FXmm-232-BD nterface adapters provide an RS232C interface for serial data communications with the MELSEC FX3S, FX3G, FX3GE or FX3U.
~~**4**~~
|Applicable for|Base units FX3S/FX3G/FX3GE<br>Base units FX3U|
|---|---|
|Interface|RS232C with 9pole D-SUB connector|
|Power supply|5 V DC/20 mA(from base unit)|
|Related I/Opoints|—<br>—|
|Weight<br>kg|0.02<br>0.02|
|Dimensions (WxHxD)<br>mm|35x51.2x17.2<br>19.3x46.1x62.7|
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-232-BD<br>**----- End of picture text -----**<br>
## **Interface adapters FX3G-422-BD, FX3U-422-BD**
**==> picture [45 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-422-BD<br>**----- End of picture text -----**<br>
The interface adapter FXmm-422-BD expand a MELSEC FX3S, FX3G, FX3GE or FX3U PLC to a second RS422 interface for connection of additional devices such as programming devices or HMIs.
## MITSUBISHI ee **Specifications FX3G-422-BD FX3U-422-BD**
|Applicable for|Base units FX3S/FX3G/FX3GE<br>Base units FX3U|
|---|---|
|Interface|RS422 with 8pole mini DIN connector|
|Power supply|5 V DC/20 mA(from base unit)|
|Related I/Opoints|—<br>—|
|Weight<br>kg|0.02<br>0.02|
|Dimensions (WxHxD)<br>mm|35x51.2x14.9<br>19.6x46.1x53.5|
**==> picture [46 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-422-BD<br>**----- End of picture text -----**<br>
## **Interface adapters FX3G-485-BD, FX3U-485-BD**
**==> picture [46 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-485-BD<br>**----- End of picture text -----**<br>
The interface adapters FXmm-485-BD provide the controller with an additional RS485 interface. The adapter, which is simply inserted into the base unit’s expansion slot, enables the
configuration of RS485 1:n multidrop, parallel link or peer-to-peer networks with FX3S, FX3G, FX3GE or FX3U systems.
## MITSUBISHI ee **Specifications FX3G-485-BD FX3G-485-BD-RJ FX3U-485-BD**
|Applicable for|Base units FX3S/FX3G/FX3GE<br>Base units FX3U|
|---|---|
|Interface|RS485/RS422|
|Power supply|5 V DC/20 mA<br>(from base unit)<br>5 V DC/40 mA<br>(from base unit)|
|Related I/Opoints|—<br>—|
|Weight<br>kg|0.02<br>0.02|
|Dimensions (WxHxD)<br>mm|35x51.2x29.2<br>35x51,2x22<br>19.6x46.1x69|
**==> picture [45 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3G-485-BD<br>**----- End of picture text -----**<br>
48
Expansion Adapter/Memory Cassettes
~~**5**~~
## ~~**Expansion adapter**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** ¨~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX2NC-CNV-IF**
The FX2NC-CNV-IF expansion adapter connects FX3UC main units with the standard FX0N/ FX2N/FX3U right side expansion bus.
~~eC~~ **Specifications FX2NC-CNV-IF** ~~SC~~ Bus connection FX3UC bus to FX0N/FX2N/FX3U bus Weight kg 0.5 Dimensions (WxHxD) mm 14.6x90x74 **Order information** Art. no. 104508
FX2NC-CNV-IF
## ~~**Memory media**~~
## ~~þ~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** ¨~~ ~~**FX3U** ¨~~ ~~**FX3UC**~~
## **Memory cassette for FX3S and FX3G/E/C**
All FX3S, FX3G, FX3GC and FX3GE base units are equipped with a slot for the optional, robust memory cassette. By connection of this memory cassette, the internal memory of the controller is switched off and only the program specified in the respective memory cassette is run.
The memory cassette can upload/download programs to and from the FX PLC internal memory with the help of 2 buttons.
The memory cassette FX3G EEPROM 32L can also be mounted on an already installed BD interface or expansion adapter.
FX3G-EEPROM-32L
**==> picture [194 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||
|---|---|---|
|Specifications|FX3G-EEPROM-32L|
|Applicable for|Base units FX3G/FX3S|
|Memory type|EEPROM|
|Size|32,000 steps (4,000 steps for FX3S)|
|Protect switch|Provided|
|Data transfer buttons|Provided|
|Order information|Art. no.|221269|
**----- End of picture text -----**<br>
**==> picture [509 x 190] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Memory media|¨|FX3S|¨|FX3G|¨|FX3GC|¨|FX3GE|þ|FX3U|þ|FX3UC|
|Memory cassettes for FX3U/FX3UC|
|The memory cassette can be installed at the|The FX3U-FLROM-64L features additional data|
|main unit, and when installed, the memory cas-|transfer buttons.|
|sette’s internal program is used in place of the|
|internal RAM memory.|
|=|CS|Specifications|FX3U-FLROM-16|FX3U-FLROM-64|FX3U-FLROM-64L|
|Applicable for|Base units FX3U/FX3UC|Base units FX3U/FX3UC|Base units FX3U/FX3UC|
|Size|16,000 steps|64,000 steps|64,000 steps|
|Memory type|Flash memory|Flash memory|Flash memory|
|Protect switch|Provided|Provided|Provided|
|Data transfer buttons|—|—|Provided|
|Dimensions (WxHxD)|mm|37x20x6.1|37x20x6.1|37x20x6.1|
|Order information|Art. no.|165278|165279|165280|
**----- End of picture text -----**<br>
49
External Terminal Blocks
~~**5**~~
## ~~**Terminal blocks**~~
**==> picture [95 x 130] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB-20C<br>eS—<br>———<br>TB-lEXl<br>2 4 6 8 10 12 14 16 18 20<br>.0 .1 .2 .3 .4 .5 .6 .7<br>**----- End of picture text -----**<br>
**==> picture [42 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
Power supply<br>terminal<br>**----- End of picture text -----**<br>
**==> picture [46 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
System adapter<br>**----- End of picture text -----**<br>
**==> picture [123 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
Sockel<br>|<br>WHI<br>Base<br>NhsEEE<br>terminal<br>TB-lEYl<br>A2- A2- A2- A2- A2- A2- A2- A2-<br>24V 24V 24V 24V 24V 24V 24V 24V<br>.0 .1 24V+.2 .3 -PLC-V8/FLK14/OUT.4Art. 22 95 55 4.5 .6 .7<br>**----- End of picture text -----**<br>
Base device structure
**==> picture [151 x 160] intentionally omitted <==**
**----- Start of picture text -----**<br>
Catch SS Terminal operation<br>aperture<br>EN<br>LED status<br>f iP /<br>display<br>-<br>\)<br>Inserted<br>a relay or<br>transistor<br>qLVL element<br>Contact for oN\<br>plug-in strip Notch lever for<br>bridge securing and<br>ejecting<br>**----- End of picture text -----**<br>
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
The TB-8EY-S and TB-8EY-C output blocks consist of 8 standard terminals and a system adapter. The standard terminals can be populated with relay or transistor elements, which makes it possible to configure the system for much higher output currents.
These terminal blocks are adapter modules that simplify the wiring of the inputs and outputs of the FX3UC main units with ribbon cable connectors. This practical, time-saving wiring system also improves the performance of the outputs. Special terminal blocks are also available for the FX3U/FX3UC positioning modules with ribbon cable connectors.
Preconfigured system cabling is available for all the terminal blocks (see next page).
Input blocks, output blocks and combined I/O blocks are available, with a choice of different terminal types.
The TB-mEXm input blocks are fitted with rows of bridged connectors for 24 V/0 V terminals, which make wiring quick and easy.
|**Specifications**|**TB-8EX-S**<br>**TB-8EX-C**<br>**TB-16EX-S**<br>**TB-16EX-C**|
|---|---|
|Type|Input block<br>Input block<br>Input block<br>Input block|
|Integrated inputs|8<br>8<br>16<br>16|
|Design|Initiator module withpotential terminals|
|Connection type|Screw terminals<br>Springterminals<br>Screw terminals<br>Springterminals|
|Application|FX2NC series base and extension modules with connectors|
|Dimensions (WxHxD)<br>mm|75x45x54<br>75x45x63<br>116x45x54<br>116x45x63|
|||
|**Order information**<br>Art. no.|149144<br>149145<br>149021<br>149022|
|||
|**Accessories**|Connection Cable(see following page)|
|**Specifications**|**TB-8EY-S**<br>**TB-8EY-C**<br>**TB-20-S**<br>**TB-20C**|
|---|---|
|Type|Output block<br>Output block<br>Input/output block<br>Input/output block|
|Channels|8<br>8<br>8/16<br>8/16|
|Design|Socket for relayor transistor elements<br>20pin terminal module|
|Connection type|Screw terminals<br>Springterminals<br>Screw terminals<br>Springterminals|
|Application|FX2NC series base and extension modules<br>with connectors<br>FX2N series positioning module|
|Dimensions (WxHxD)<br>mm|49.6x100x94<br>49.6x100x94<br>75x45x52<br>75x45x52|
|||
|**Order information**<br>Art. no.|149044<br>149045<br>149148<br>149023|
|||
|**Accessories**|Pluggable function elements (see below),<br>Connection cable(see following page)<br>Connection cable (see following page)|
The transistor and relay elements are plugged directly into the standard terminals in the TB-8EY-S or TB-8EY-C modules. All the elements feature a status LED, protection against reverse polarity connection and a freewheeling diode.
Neighbouring terminals with identical voltages can be connected with plug-in strip bridge connectors, which can be cut to length as required.
|**Specifications**|**TB-8RELAY-6A**<br>**TB-8TRANSISTOR-2A**|
|---|---|
|Output type|Relaywith 1 switch-over contact<br>Transistor(with optocoupler)|
|Number of elements|8<br>8|
|Rated input voltage|24 V DC<br>24 V DC|
|Switchingvoltage(min./max.)|12 V AC/DC;250 V AC/DC<br>3 V DC;33 V DC|
|Limitpermanent current|6 A<br>3 A(at 20 °C),2 A(at 60 °C)|
|Max. breakingcapacity|140 W(24 V DC),1500 VA(250 V AC)<br>—|
|Ambient temperature|-20–+60 °C<br>-20–+60 °C|
|||
|**Order information**<br>Art. no.|149034 (set with 8 elements)<br>149035 (set with 8 elements)|
|||
|**Accessories**|Insulated infinite pin bridge for potential isolation, TB-PIB-RD, color red, art.-no.: 149146;<br>Insulated infinite pin bridge for potential isolation, TB-PIB-BL, color blue art.-no.: 149147;<br>Isolationplate TB-SP for lateral base terminal connection,art.-no.: 149158|
50
Cable and Connection Terminals
~~**5**~~
## ~~**Terminal connection cable**~~
## ~~¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
These preconfigured cables enable quick, The cables are available in a choice of lengths error-free wiring of the terminal blocks of the between 1 and 5 m. Other lengths are also pospositioning modules for the FX3U and FX3UC sible by special order. series fitted with ribbon cable connectors. **Specifications TB-EX-CAB-1M TB-EX-CAB-3M TB-EX-CAB-5M** OO» ~~ee~~ Application For TB-lEXl and TB-20-l (1:1 cable) Length m 1 3 5 **Order information** Art. no. 149038 149039 149040 ~~ee~~ **Specifications TB-EY-CAB-1M TB-EY-CAB-3M TB-EY-CAB-5M** Application For 2 x terminal block TB-8EY-S or TB-8EY-C (Y cable) Length m 1 3 5 **Order information** Art. no. 149041 149042 149043 ~~**Connection terminals** ¨~~ ~~**FX3S** ¨~~ ~~**FX3G** ¨~~ ~~**FX3GC** ¨~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
The base unit FX2NC-16MR-T-DS and the extenThese plug-in terminals can easily be replaced sion units FX2NC -16EX-T-DS and FX2NC-16EYRwith spring terminals if required. T-DS are fitted with screw terminals as standard Two replacement terminal units are required for equipment. each module with 16 I/Os.
~~ee~~ **Specifications TB-CON-5-C TB-CON10-C** Number of terminal points 5 10 Connection type Spring terminals Spring terminals Adapter modules and FX2NC-16EX-T-DS/ Application Adapter modules FX2NC-16EYR-T-DS extension modules Dimensions (WxHxD) mm 12.5x20x21 12.5x20x21 **Order information** Art. no. 221539 149036
51
Power Supplies/Batteries
~~**5** -~~
## ~~**24 V power supply unit**~~
## ~~þ~~ ~~**ALPHA** þ~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
Up to 5 power supply units can be installed together for redundant mode operation or connected in parallel for more power. The units have an integrated thermal overload protection circuit and a POWER LED. The output voltage is adjustable.
The ALPHA-POWER units are a convenient power supply for 24 V units and other external devices. They come with mounting systemfor wall or DIN rail mounting and their dimensions are matched to those of the ALPHA family.
|5 <br>\S<br>TULL|adjustable.<br>**Specifications**<br>**ALPHA POWER 24-0.75**<br>**ALPHA POWER 24-1.75**<br>**ALPHA POWER 24-2.5**<br>Application<br>Power supplyfor 24 V DC Alpha base units<br>General specifications<br>Conforms to FX familyand ALPHA base units<br>Nominal input voltage<br>100–240 V(45–65 Hz)<br>Output voltage<br>24 V DC(+/-1 %)<br>Nominal output current<br>0.75 A(at T=55 °C)<br>1.75 A(at T=55 °C)<br>2.5 A(at T=55 °C)<br> ~~ee~~|
|---|---|
||Max. output current<br>1.4 A<br>3.75 A<br>4.4 A|
||Ambient temperature<br>-25–+55 °C(operation),-40–+85 °C(storage)|
||Ambient humidity<br>max. 95 %(no condensation)|
||Weight<br>kg 0.1<br>0.2<br>0.3|
||Dimensions (WxHxD)<br>mm 36x90x61<br>54x90x61<br>72x90x61|
|||
||**Order information**<br>Art. no. 209029<br>209030<br>209031|
~~**5 V power supply unit**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
The power supply modules FX3U-1PSU-5V and FX3UC-1PS-5V are used to reinforce the build-in 5 V DC and 24 V DC power supply of a FX3G/ FX3GC/FX3GE/FX3U/FX3UC main unit.
Up to two FX3U-1PSU-5V or FX3UC-1PS-5V modules can be used.
Both modules have an integrated overload protection available.
They do not occupy any I/O points and deliver up to 1 A more current for the 5 V system bus (for special function modules).
FX3U-1PSU-5V
**==> picture [30 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX -1PSU-5V3U<br>**----- End of picture text -----**<br>
|Application|Power supply for the FX3G/FX3U system bus<br>Power supply for the FX3G/FX3GC/FX3UC<br>system bus|
|---|---|
|General specifications|Conforms to FX familybase units|
|Nominal input voltage|100–240 V(50/60 Hz)<br>24 V DC(+20 %/-15 %)|
|Output voltage|5 V DC/24 V DC<br>5 V DC|
|Max. output current<br>5 V DC <br>24 V DC|1 A at 40 °C;0.8 A at 55 °C<br>1 A|
||0.3 A at 40 °C;0.2 A at 55 °C<br>—|
|Ambient temperature|-25–+55 °C(operation),-40–+85 °C(storage)|
|Ambient humidity|max. 95 %(no condensation)|
|Weight<br>kg|0.3<br>0.15|
|Dimensions (WxHxD)<br>mm|55x90x87<br>24x90x74|
Note:
The FX3U-1PSU-5V can't be used with a 24 V base unit!
When connecting an input extension module (incl. FX2N-8ER-ES/UL, FX2N-8ER) to the FX3U-1PSU-5V, supply the power for it from the 24 V DC service power supply of the connected main unit or powered extension unit on the upstream side.
FX3UC-1PS-5V
**==> picture [91 x 12] intentionally omitted <==**
**----- Start of picture text -----**<br>
Backup batteries<br>**----- End of picture text -----**<br>
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **Batteries**
The battery buffers the internal RAM of the The battery FX3U-32BL can be used for all base MELSEC PLC in the event of a voltage failure. units of the MELSEC FX3G/FX3GC/FX3GE/FX3U/ FX3UC series. **Specifications FX2NC-32BL FX3U-32BL** Applicable for FX2N-20GM-Modul Base units FX3G/FX3GC/FX3GE/FX3U/FX3UC GS ) ~~CS~~ **Order information** Art. no. 128725 165286 FX3U-32BL
52
Cables
## ~~**Cables**~~
## ~~þ~~ ~~**ALPHA** þ~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
## **FX Series connection cables**
The cable listed in the following tables are used applications, block connections and interface for FX Series PLC programming, positioning conversion.
## **Connection cable for RS232C peripherals**
**==> picture [45 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX-20P-CAB0<br>**----- End of picture text -----**<br>
**==> picture [52 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX-16E-500CAB<br>**----- End of picture text -----**<br>
|**Specifications**|**F2-RS-5CAB**<br>**F2-232CAB-1**<br>**FX-232CAB-1**|||
|---|---|---|---|
|Applicable for|FX2N-1RM to resolver<br>PC to FX-232AWC-H<br>PC to GOT|||
|Length<br>m|5.0<br>3.0<br>3.0|||
|**Order information**<br>Art. no.|76160<br>76163<br>124972|||
|**Connection cable for RS422 peripherals**||||
|**Specifications**<br>**FX-422CAB0**<br>**FX-422CAB**<br>**FX-422CAB-150**<br>Application<br>FX-232AWC-H to FXmPLC<br>FX-232AWC-H to FX PLC<br>FX-232AWC-H to FX PLC<br>Length<br>m 1.5<br>0.3<br>1.5<br>**Order information**<br>Art. no. 76094<br>25949<br>—<br>**Connection cable for programming unit**<br>~~a~~||||
|**Specifications**<br>Application<br>Length<br>m|**FX-20P-CAB0**<br>**FX-20P-CAB**<br>**FX-20P-CADP**<br>FX-20P-G/FX-30P to FXmPLC<br>FX-20P-E to FX PLC<br>FX-20P-CAB to FXmPLC<br> 1.5<br>1.5<br>0.3||~~**5**~~|
|**Order information**<br>Art. no.|55917<br>30815<br>31870||Accessories|
## **Connection cable for extension bus**
|**Specifications**|**FX0N-65EC**<br>**FX2N-CNV-BC**|
|---|---|
|Application|PLC bus cable for two-stage-configuration with<br>extension units FXmm-mmES<br>Adapter for the connection of the FX0N-65EC to<br>special function modules FX3U/FX2N|
|Length<br>m|0.65|
|||
|**Order information**<br>Art. no.|45348<br>70880|
FX0N-65EC
**Interface converter**
~~ee~~ **Specifications FX-USB-AW FX-232AWC-H** Application USB to RS422 converter RS422 to RS232C converter Dimensions (WxHxD) mm 62x21x15 80x60x25 **Order information** Art. no. 165288 159642
## ~~**Programming cables**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** þ~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
The USB to RS-422 converter FX-USB-AW is used The SC-09 programming cable is used for the for the connection between the PLC and a serial connection between the PLC and a serial interinterface of a personal computer. The converter face of a personal computer. The cable is deviis devided into 2 parts and thus universally ded into 2 parts and thus universally applicable applicable for all FX-series PLCs. for all Mitsubishi Electric PLCs.
**==> picture [39 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX-USB-AW<br>**----- End of picture text -----**<br>
ee **FX-USB-AW SC-09** Connection on PC side USB 9-pin D-SUB **Order information** Art. no. 165288 43393
53
Displays
~~**5**~~
## ~~**Display modules**~~
## ~~¨~~ ~~**FX3S** þ~~ ~~**FX3G** ¨~~ ~~**FX3GC** þ~~ ~~**FX3GE** þ~~ ~~**FX3U** þ~~ ~~**FX3UC**~~
**==> picture [77 x 64] intentionally omitted <==**
**----- Start of picture text -----**<br>
a<br>MITSUBISHI<br>ESC - + OK<br>**----- End of picture text -----**<br>
## **Display module FX3G-5DM**
The display module FX3G-5DM is inserted directly with space-saving into the controller and enables monitoring and editing of the data stored in the PLC.
The display module e.g. can be used instead of digital switches and external 7-segment displays in very confined areas.
|**Specifications**|**FX3G-5DM**|
|---|---|
|Applicable for|Base units FX3G/FX3GE|
|Display|LCD(with backlight)|
|Power supply|5 V DC ±5 %(from base unit)|
|Current consumption<br>mA|n/a|
|Dimensions (WxHxD)<br>mm|49x34x12|
|**Order information**<br>Art. no.|221270|
## **Control and display panel FX-10DM-E**
The control and display panel FX-10-DM-E proThe connection with the PLC is possible via the vides a key-oriented user-interface and enables cable FX-20P CAB0. you to monitor and edit process data in the PLC.
The display is arranged in 2 rows of 16 characters each. Functions can be invoked and values can be edited using the panel keys.
can be edited using the panel keys. OWNED ~~i~~ **Specifications FX-10DM-E**
|**Specificationspecificationsecifications**<br>**FX-10DM-E**<br>~~i~~|
|---|
|Applicable for<br>All base units FX3U<br>~~i~~|
|Display<br>LCD(with backlight)|
|Resolution<br>2x16 signs(80x16pixles)|
|Power supply<br>5 V DC ±5 %(from base unit)|
|Current consumption<br>mA 220|
|Weight<br>kg 0.02|
|Dimensions (WxHxD)<br>mm 96x62x32|
|**Order information**<br>Art. no. 132600|
## **Control and display panel FX3U-7DM, holder FX3U-7DM-HLD**
Panel FX3U-7DM with built-in holder FX3U-7DM-HLD
The FX3U-7DM display module can be incorporated in the main unit, or can be installed in
the enclosure using the FX3U-7DM-HLD display module holder.
|Applicable for|Base units FX3U<br>Base units FX3U|
|---|---|
|Display|16 letters x 4 lines<br>—|
|Resolution|—<br>—|
|Power supply|5 V DC(from base unit)<br>—|
|Current consumption<br>mA|20<br>—|
|Extension cable|—<br>Included|
|Weight<br>kg|0.02<br>0.01|
|Dimensions (WxHxD)<br>mm|48x35x11.5<br>66.3x41.8x13|
Please refer to the HMI family catalogue for further operator terminals
54
Dimensions ALPHA
~~**6**~~
## **Dimensions of the ALPHA series**
AL2-14Ml-l, AL2-24Ml-l
**==> picture [446 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
6,0 6,0<br>ĐĐ Đ Đ ĐĐĐĐĐĐĐĐ Đ (A) Đ Đ (B) DC INPUT + - (A) (B) 1 2 3 4 5 DC INPUT 6 7 8 9 10 11 12 13 14 15<br>ĐĐĐ<br>MITSUBISHI POWER24V DC<br>MITSUBISHI<br>ĐĐ ESC ESC<br>+ +<br>- -<br>OK OK<br>AL2-10MR-D AL2-24MR-D<br>RELAY<br>OUT1 OUT2 OUT3 OUT4 OUTPUTOUT 5 6 7 8 9<br>6,0 6,0<br>52,0 71,2 124,6<br>4,0 4,0<br>090, 090,<br>4,0 4,0<br>**----- End of picture text -----**<br>
AL2-4EYl, AL2-2DA
AL2-ASI-BD
AL2-2PT-ADP, AL2-2TC-ADP
**==> picture [489 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
53,1 24,5 53,1 24,5 35,5 33,5<br>+ - V1+ V1- V2+ V2-<br>+ EI1 - + EI2 - ASI+ ASI- ASI+ ASI- POWER24V DC OUTPUTCH1 0~10VCH2<br>MITSUBISHI<br>MITSUBISHI POWER<br>200°C -50°CCH1 Line 200°C CH2-50°C Line<br>AL2-2PT-ADP<br>4EX PT100 -50~200°C<br>+ EI3 - + EI4 - CH1 CH2<br>L1+ L1- I1- L2+ L2- I2-<br>90<br>90 90<br>4<br>**----- End of picture text -----**<br>
All dimensions in mm
55
Dimensions FX3S/FX3G/FX3GE Base Units
~~**6**~~
## **Dimensions of base units FX3S**
**==> picture [329 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 75<br>X – 8<br>2 x ø4,5<br>90 82<br>**----- End of picture text -----**<br>
**==> picture [163 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units X<br>FX3S-10MR-ES 60<br>FX3S-10MT-ESS 60<br>FX3S-14MR-ES 60<br>FX3S-14MT-ESS 60<br>FX3S-20MR-ES 75<br>FX3S-20MT-ESS 75<br>FX3S-30MR-ES 100<br>FX3S-30MT-ESS 100<br>**----- End of picture text -----**<br>
**==> picture [54 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
All dimensions in mm<br>**----- End of picture text -----**<br>
## **Dimensions of base units FX3G**
**==> picture [327 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87<br>X - 8<br>ø4,5<br>90 35<br>**----- End of picture text -----**<br>
**==> picture [163 x 52] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units X<br>FX3G-14 90<br>FX3G-24 90<br>FX3G-40 130<br>FX3G-60 175<br>**----- End of picture text -----**<br>
**==> picture [54 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
All dimensions in mm<br>**----- End of picture text -----**<br>
## **Dimensions of base units FX3GE**
**==> picture [509 x 129] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87 Base units X<br>X - 8 FX3GE-24 130<br>FX3GE-40 175<br>ø4,5<br>90 35<br>**----- End of picture text -----**<br>
All dimensions in mm
56
Dimensions FX3GC/FX3U/FX3UC Base Units
~~**6**~~
## **Dimensions of base units FX3GC**
**==> picture [6 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
X<br>**----- End of picture text -----**<br>
**==> picture [72 x 133] intentionally omitted <==**
**==> picture [119 x 154] intentionally omitted <==**
|**Base units**<br>**X**|**Base units**<br>**X**|
|---|---|
|FX3GC-32MT/DSS|35|
All dimensions in mm
## **Dimensions of base units FX3U**
**==> picture [333 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 86<br>22 X1<br>L N S/S 0V 24V X0 X1 X2 X3 X4 X5 X6 X7<br>IN 0347 1256<br>POWER<br>RUN<br>BATT<br>ERROR<br>FX3U -16M OUT 0347 1256<br>Y0 Y0 Y1 Y1 Y2 Y2 Y3 Y3 Y4 Y4 Y5 Y5 Y6 Y6 Y7 Y7<br>R<br>Ø 4.5<br>90 80<br>**----- End of picture text -----**<br>
**==> picture [163 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units X X1<br>FX3U-16Mmmm 130 103<br>FX3U-32Mmmm 150 123<br>FX3U-48Mmmm 182 155<br>FX3U-64Mmmm 220 193<br>FX3U-80Mmmm 285 258<br>FX3U-128Mmmm 350 323<br>**----- End of picture text -----**<br>
All dimensions in mm
## **Dimensions of base units FX3UC**
**==> picture [6 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
X<br>**----- End of picture text -----**<br>
**==> picture [72 x 134] intentionally omitted <==**
**==> picture [119 x 154] intentionally omitted <==**
**==> picture [163 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
Base units X<br>FX3UC-16MT/DSS 34<br>FX3UC-32MT/DSS 34<br>FX3UC-64MT/DSS 59.7<br>FX3UC-96MT/DSS 85.4<br>**----- End of picture text -----**<br>
All dimensions in mm
57
Dimensions Extension Units
## **Dimensions of adapter modules FX3U and extension adapters**
## **Extension adapters**
**==> picture [509 x 188] intentionally omitted <==**
**----- Start of picture text -----**<br>
74 15.5 17.6 Ø3.2<br>Type X<br>FX3U-CNV —<br>FX3U-4AD-ADPPOWER FX3U-USB —<br>FX3U-485 15.5<br>FX3U-422 —<br>FX3U-232 9.2<br>53.5 19.6<br>Ø3.2<br>53.5 X 19.6 All dimensions in mm<br>24+ 46.1<br>24-<br>V1+<br>061 90 COM1COM2I1+V2+I2+<br>V3+<br>COM3I3+<br>V4+<br>COM4I4+<br>.1<br>6<br>4<br>**----- End of picture text -----**<br>
## **Dimensions of compact extension units and modular extension blocks MELSEC FX2N**
~~**6**~~
**==> picture [224 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87<br>ø4,5<br>IN 0<br>1<br>2<br>3<br>4<br>5<br>6<br>7<br>POWER<br>FX -16EX2N<br>IN 0<br>1<br>2<br>3<br>4<br>5<br>6<br>7<br>4<br>90 80 35<br>**----- End of picture text -----**<br>
## **Compact extension units**
**==> picture [163 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X<br>FX2N-32Emmm 150<br>FX2N-48Emmm 182<br>FX2N-48ER-UA1/UL 220<br>Modular extension blocks<br>Type X<br>FX2N-8Emmm 43<br>FX2N-16Emmm 40<br>**----- End of picture text -----**<br>
All dimensions in mm
## **Dimensions of modular extension blocks FX2NC**
**==> picture [230 x 153] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 74 Y<br>FX2NC-32EX-DS<br>PowerX0X4X0X4123567123567 X0X4X0X4123567123567<br>90<br>**----- End of picture text -----**<br>
## **Extension blocks**
**==> picture [163 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X Y<br>FX2NC-16EX-DS 14.6 13<br>FX2NC-16EYT-DSS 14.6 13<br>FX2NC-16EX-T-DS 20.2 15<br>FX2NC-16EYR-T-DSS 24.2 15<br>FX2NC-32EX-DS 26.2 13<br>FX2NC-32EYT-DSS 26.2 13<br>**----- End of picture text -----**<br>
All dimensions in mm
58
Dimensions Special Function Modules
~~**6**~~
## **Dimensions of special function modules MELSEC FX2N**
**==> picture [252 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87<br>ø4,5<br>POWER<br>FX -4AD2N<br>24 V<br>A / D<br>4<br>90 80 35<br>**----- End of picture text -----**<br>
FX2N-8AD
FX2N-32DP-IF
**==> picture [301 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
75 75<br>RUN<br>STOP<br>24+ 24- V1+ V2+ I1+ I2+COM1COM2V3+ V4+ I3+ I4+COM3COM4 L NCOM 24 +<br>MITSUBISHI MITSUBISHI<br>FX2N-8AD POWER<br>RUN<br>POWER BF<br>RUN DIA<br>FX2N-32DP-IF<br>V6+ I6+ COM6 V8+ I8+ COM8<br>V5+ I5+ COM5 V7+ I7+ COM7<br>ON<br>OFF<br>105 98 90 106 98 90<br>64 32 61 8 4 2 1<br>**----- End of picture text -----**<br>
## **Special function modules FX0N/FX2N**
**==> picture [163 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X<br>FX0N-3A 43<br>FX2N-2DA 43<br>FX2N-2AD 43<br>FX2N-4DA 55<br>FX2N-4AD 55<br>FX2N-4AD-TC 55<br>FX2N-4AD-PT 55<br>FX2N-1HC 55<br>FX2N-10PG 43<br>FX2N-2LC 55<br>FX2N-5A 55<br>FX2N-232-IF 55<br>FX2N-64DNET 43<br>**----- End of picture text -----**<br>
**==> picture [125 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
90<br>75<br>35<br>**----- End of picture text -----**<br>
All dimensions in mm
## **Dimensions of special function modules MELSEC FX3U/FX3UC**
**==> picture [252 x 161] intentionally omitted <==**
**----- Start of picture text -----**<br>
X 87<br>ø4,5<br>POWER<br>FX -4AD3U<br>24 V<br>A / D<br>4<br>90 80 35<br>**----- End of picture text -----**<br>
## **Special function modules FX3U/FX3UC**
**==> picture [163 x 175] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X<br>FX3U-2HC 55<br>FX3U-3A-ADP 17.6<br>FX3U-4DA 55<br>FX3U-4AD 55<br>FX3U-4LC 90<br>FX3U-CF-ADP 45<br>FX3U-ENET 55<br>FX3U-CAN 43<br>FX3U-20SSC-H 55<br>FX3U-64CCL-M 55<br>FX3U-64DP-M 43<br>FX3U-1PSU-5V 55<br>FX3UC-4AD 20.2<br>FX3UC-1PS-5V 24.2<br>FX3U-1PG 43<br>FX3U-J1939 43<br>**----- End of picture text -----**<br>
All dimensions in mm
59
Dimensions Special Function Modules
## **Dimensions of adapters FX3G**
## FX3G-485-BD
**==> picture [67 x 92] intentionally omitted <==**
## **FX3G extension adapters**
**==> picture [163 x 73] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type X X1<br>FX3G-1DA-BD 14.1 15.1<br>FX3G-232-BD 12 5.2<br>FX3G-2AD-BD 14.1 15.1<br>FX3G-422-BD 12 2.9<br>FX3G-485-BD 14.1 15.1<br>FX3G-8AV-BD 12 —<br>**----- End of picture text -----**<br>
All dimensions in mm
## **Dimensions for terminal blocks**
~~**6**~~
TB-20-S 75
**==> picture [358 x 512] intentionally omitted <==**
**----- Start of picture text -----**<br>
TB-20-S<br>75 50<br>TB-20-C<br>75 50<br>TB-8EX-S<br>75 54<br>TB-8EX-C<br>75 63<br>TB-16EX-S<br>116 62<br>TB-16EX-C<br>116 54<br>45<br>45<br>45<br>45<br>45<br>45<br>**----- End of picture text -----**<br>
60
Dimensions Accessories
~~**6**~~
## **Dimensions of the memory cassettes**
FX3G-EEPROM-32L
**==> picture [74 x 102] intentionally omitted <==**
**==> picture [62 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-FLROM-16/64/64L<br>**----- End of picture text -----**<br>
**==> picture [110 x 37] intentionally omitted <==**
**==> picture [54 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
All dimensions in mm<br>**----- End of picture text -----**<br>
## **Dimensions for display panels**
**==> picture [438 x 246] intentionally omitted <==**
**----- Start of picture text -----**<br>
FX3U-7DM FX3G-5DM<br>11.5<br>8.5 48<br>FX-10DM-E<br>96 32<br>MITSUBISHI<br>DISPLAY MODULE<br>MODEL FX-10DM-E<br>SERIAL 030002 V1.00<br>MITSUBISHI ELECTRIC CORPORATION<br>CLR FNC ENT<br>35<br>62 53<br>**----- End of picture text -----**<br>
**==> picture [12 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
4,5<br>**----- End of picture text -----**<br>
**==> picture [10 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
86<br>**----- End of picture text -----**<br>
All dimensions in mm
61
Programming
~~**7**~~
## **MELSOFT – programming and documentation software for standard personal computers**
With the MELSOFT software family Mitsubishi Electric offers efficient software packages helping to reduce programming and setup times to a high degree. The MELSOFT software family provides instant access, direct communications, compatibility, and open exchange of variables. The MELSOFT family comprises:
- z Programming packages AL-PCS/WIN and GX Works2/GX Works2 FX
- z Various development software for operator terminals (please refer to the technical catalogue HMI)
AL-PCS/WIN is recommended as a cost-effective beginners package for the ALPHA series. This package offers a quick and easy introduction to programming.
GX Works2 is the right decision for a universal programming package. In addition to the FX family, the MELSEC L series and the MELSEC System Q can be programmed.
For detailed information please order our separate MELSOFT brochure.
- z Software for a dynamic data exchange like MX Change
## ~~**ALPHA programming software**~~
## **AL-PCS/WIN programming software**
All controllers of the ALPHA series can be click to build the logic. By this, programs with programmed with the MS Windows® software up to 200 function blocks can be created, where AL-PCS/WIN. Programming the ALPHA with this each single function in a program can be used software is very easy and is done by placing as many times as desired. the different program elements on a graphical A complete documentation of the program can programming environment. The connections be created directly from AL-PCS/WIN. (wiring) between the inputs, function blocks, and outputs are drawn graphically by mouse
click to build the logic. By this, programs with up to 200 function blocks can be created, where each single function in a program can be used as many times as desired.
|**Software**<br>**(AL-PCS/WIN)**<br>ee|**Software**<br>**(AL-PCS/WIN)**<br>ee|
|---|---|
|Series|Alpha series|
|Language|7 languages(English/German/French/Italian/Spanish/Swedish/Russian)|
|Einsetzbar bei|Windows 95/98/ME/NT/2000/XP/Vista/7|
|||
|**Order information**<br>Art. no.|215028|
Note: The AL-PCS/WIN software can be downloaded free of charge
62
Programming
~~**7**~~
## **PLC programming software**
## ~~**GX Works2/GX Works2 FX**~~
GX Works2 is the PLC programming environment of the next generation. It supports all PLC of the MELSEC System Q, L and FX series and offers numerous functions to faciliate programming work and support the user. GX Works2 FX has the same functionality as GX Works2 but just for FX PLC´s.
The following programming languages are available:
- z ST (Structured Text) z FBD (Function Block Diagram)
- z SFC (Sequential Function Chart) z IL (Instruction List) – planned capability
- z LD (Ladder Diagram)
The main features of GX Works2 are:
- z Integrated parameterization of special function modules (analog, temperature, positioning, counter, network)
- z Comprehensive diagnostics and debugging functions support the user in troubleshooting and fault clearance.
- z Use of program and function block libraries z Revision verification and restoration makes it save time for programming and minimizes possible to restore old program versions or to errors. compare with programs from the PLC.
- z Integrated simulation allows offline testing of z GX Works2 is compatible with GX Developer the software and the configuration. and GX IEC Developer projects (as far as the editors are supported)
|**Software**<br>**Series**<br>**Language**<br>**Disk type**<br>**Art. no.**<br>eee|**Software**<br>**Series**<br>**Language**<br>**Disk type**<br>**Art. no.**<br>eee|**Software**<br>**Series**<br>**Language**<br>**Disk type**<br>**Art. no.**<br>eee|**Software**<br>**Series**<br>**Language**<br>**Disk type**<br>**Art. no.**<br>eee|
|---|---|---|---|
|GX Works2 FX V01-2L0C-E<br>GX Works2 FX V01-2L0C-E-INTRODUCTION|FX3S, FX3G, FX3GC, FX3GE, FX3U, FX3UC<br>English<br>DVD|255804<br>256745||
|||||
|GX Works2 V01-2L0C-E||234630||
|GX Works2 V01-5L0C-E||234631||
|GX Works2 V01-2L0C-E-UPGRADE|All MELSEC PLCs<br>English<br>DVD|234632||
|GX Works2 V01-5L0C-E-UPGRADE||234634||
|GX Works2 V01-2L0C-E-INTRODUCTION||234789||
|||||
|GX Works2 V01-2L0C-G||244876||
|GX Works2 V01-5L0C-G<br>GX Works2 V01-2L0C-G-INTRODUCTION|All MELSEC PLCs<br>German<br>DVD|244877<br>244878||
|||||
|Accessory|Programmingcable SC-09|43393||
63
Programming
## **Software for Profibus networks**
## ~~**GX Configurator DP**~~
The GX Configurator DP is a user friendly configurations software for the open network Profibus DP.
The software package is a 32 bit application and runs under all Windows versions.
Configuration of all Profibus DP modules for the MELSEC Ans/QnAS and A/Q series and also the FX family is possible.
Due to the supported extended user parameters of a GSD file, easy parameter setting of Profibus DP slave devices is possible even for third-party devices.
The new GX Configurator DP enables the download of all configuration data via an overriding network.
All Profibus modules are configured via the backside bus.
|Pe|**Software**<br>**GX Configurator DP V07-1L0C-M**<br> ee|**Software**<br>**GX Configurator DP V07-1L0C-M**<br> ee|
|---|---|---|
||Supported Profibus DP master modules<br>for the Mitsubishi Electric MELSEC series|A1SJ71PB92D, AJ71PB92D, QJ71PB92D|
||Language|English/German|
||Disk type|CD ROM|
||||
||**Order information**<br>Art. no.|231731|
||||
||**Accessory**|Programmingcable SC-09,art. no.: 43393|
## ~~**FX Configurator FP**~~
~~**7**~~
FX Configurator-FP is beneficial for setting up table operation information, servo amplifier parameters and positioning parameters for the FX3U-SSC-H positioning module. Positioning operations and their associated parameters (speeds, addresses, torque limits etc.) can be monitored and tested with the integrated monitor and test functions.
Control patterns from simple to complicated combinations of positioning commands can easily be configured with new methods.
The software runs under all Windows® versions.
|**Software**|**FX Configurator FP V0100-1LOC-E**|
|---|---|
|Supported modules for the Mitsubishi Electric<br>MELSEC series|FX3U-20SSC-H|
|Language|English|
|Disk type|CD ROM|
|||
|**Order information**<br>Art. no.|189283|
|||
|**Accessory**|Programmingcable SC-09,art. no.: 43393|
64
Programming
~~**7**~~
## ~~**Hand-held programming unit**~~
## **FX-30P programming unit**
can be downloaded on a PC then installed via the USB port. PLC programs on the PC can also be transferred via USB, eliminating the need for peripheral devices.
The FX-30P is a small, industrial programming and maintenance tool for the FX Series. This unit can perform program uploads/downloads and store up to 15 programs in its internal memory. Keywords can be registered, deleted or canceled in applicable PLCs. Program monitoring and data device adjustment functionality is also available. To stay up to date the latest firmware
Note: FX-30P firmware and program downloads from a PC via the embedded USB port available in firmware versions 1.10 and later.
ded USB port available in firmware versions 1.10 and later. data device adjustment functionality is also Ness available. To stay up to date the latest firmware ~~a~~ **Specifications FX-30P**
|**Specificationspecificationsecifications**<br>~~a~~|~~a~~|**FX-30P**<br>~~a~~|
|---|---|---|
|Applicable for<br>~~a~~|~~a~~|Base units FX1S,FX1N,FX3G,FX2N,FX3U,FX3UC<br>~~a~~|
|Ambient temperature||0–40 °C|
|Ambient relative humidity (non-condensing)||5–95 %|
|Power supply||5 V DC ±5 %/155 mA(from main unit)|
|Display||LCD(with backlight)|
|Character display||21x8|
|Keyboard||35|
|Memory|Program capacity|Built-in RAM: 64K steps for program monitoring and modification RAM retention<br>(for about fiveyears,ambient temperature 25 C(77 F))bybattery.<br>Built-in flash memory ROM: Up to 15 programs can be stored in the built-in flash memory<br>ROM. Allowable number of writes: 100,000 times|
||HPP held data|Display language setting (Japanese, English or Chinese), contrast, buzzer sound volume,<br>brightness adjustment, screen saver and HPP protect key (saved in the built-in flash<br>memory)|
|Cable||FX-20P-CAB0|
|Weight|kg|0.3|
|Dimensions (WxHxD)|mm|87x170x30|
||||
|**Order information**|Art. no.|221271|
65
Certifications
**==> picture [513 x 579] intentionally omitted <==**
**----- Start of picture text -----**<br>
CE uL Ship approvals CE uL Ship approvals<br>Module type EMC LVD* cUL ABS DNV LR GL BV RINA Module type EMC LVD* cUL ABS DNV LR GL BV RINA<br>ALPHA 2 base units FX3U base units<br>AL2-10MR-A P P P — — — — — — FX3U-16m P P P P P P P P P<br>AL2-10MR-D P P P — — — — — — FX3U-32m P P P P P P P P P<br>AL2-14MR-A P P P — P — — — — FX3U-48m P P P P P P P P P<br>AL2-14MR-D P P P — P — — — — FX3U-64m P P P P P P P P P<br>AL2-24MR-A P P P — P — — — — FX3U-80m P P P P P P P P P<br>AL2-24MR-D P P P — P — — — — FX3U-128m P P P P P P P P P<br>ALPHA extension modules FX3UC base units<br>AL2-4EX-A2 P P P — P — — — — FX3UC-16MT/DSS P P P — P — — — —<br>AL2-4EX P P P — P — — — — FX3UC-32MT/DSS P P P — P — — — —<br>AL2-4EYR P P P — P — — — — FX3UC-64MT/DSS P P P — P — — — —<br>AL2-4EYT P P P — P — — — — FX3UC-96MT/DSS P P P — P — — — —<br>AL2-2DA P P P — — — — — — FX0N/FX2N extension units<br>AL2-2PT-ADP P P P — — — — — — FX0N-40ER-ES/UL P P P — P — — — —<br>AL2-2TC-ADP P P P — — — — — — FX0N-40ER-DS P P — — P — — — —<br>AL2-ASI-BD P P P — P — — — — FX0N-40ET-DSS P p — — P — — — —<br>FX3S base units FX2N-32ER-ES/UL P P P P P P P P P<br>FX3S-10MR-SS P P P — — — — — — FX2N-32ET-ESS/UL P P P P P P P P P<br>FX3S-10MT-ESS P P P — — — — — — FX2N-48ER-DS P P P P P — — — —<br>FX3S-14MR-ES P P P — — — — — — FX2N-48ER-ES/UL P P P P P P P P P<br>FX3S-14MT-ESS P P P — — — — — — FX2N-48ET-DSS P p P P P — — — P<br>FX3S-20MR-ES P P P — — — — — — FX2N-48ET-ESS/UL P P P P P P P P P<br>FX3S-20MT-ESS P P P — — — — — — FX2N extension blocks<br>FX3S-30MR-ES P P P — — — — — — FX2N-8ER-ES/UL P P P — — — — — —<br>FX3S-30MT-ESS P P P — — — — — — FX2N-8EX-ES/UL P p P — — — — — —<br>FX3G base units FX2N-8EYR-ES/UL P P P — — — — — —<br>FX3G-14MR/ES P P P — — — — — — FX2N-8EYT-ESS/UL P p P — — — — — —<br>FX3G-14MT/ESS P P P — — — — — — FX2N-16EX-ES/UL P p P P P P P P P<br>FX3G-14MR/DS P P P — — — — — — FX2N-16EYR-ES/UL P P P P P P P P P<br>FX3G-14MT/DSS P P P — — — — — — FX2N-16EYT-ESS/UL P p P P P P P P P<br>FX3G-24MR/ES P P P — — — — — — FX1N/FX2N special function modules<br>FX3G-24MT/ESS P P P — — — — — — FX0N-3A P — — — — — — — —<br>FX3G-24MR/DS P P P — — — — — — FX2N-1HC P P P P P P P P P<br>FX3G-24MT/DSS P P P — — — — — — FX2N-2AD P p P P — — — — —<br>FX3G-40MR/ES P P P — — — — — — FX2N-2DA P p P P — — — — —<br>FX3G-40MT/ESS P P P — — — — — — FX2N-2LC P p P — — — — — —<br>FX3G-40MR/DS P P P — — — — — — FX2N-4AD P p P P P P P P P<br>FX3G-40MT/DSS P P P — — — — — — FX2N-4AD-TC P p P P P P P P P<br>FX3G-60MR/ES P P P — — — — — — FX2N-4AD-PT P p P P P P P P P<br>FX3G-60MR/DS P P P — — — — — — FX2N-4DA P p P P P P P P P<br>FX3G-60MT/ESS P P P — — — — — — FX2N-5A P p P — — — P — P<br>FX3G-60MT/DSS P P P — — — — — — FX2N-8AD P p P — — — P — P<br>FX3GE base units FX2N-10PG P p P — — — — — —<br>FX3GE-24MT/ESS P P P — — — — — — FX2N-32CCL P p — — — — — — —<br>FX3GE-40MT/ESS P P P — — — — — — FX2N-32DP-IF P P P — P — — — —<br>FX3GE-24MR/DS P P P — — — — — — FX2N-64DNET P p P — — — — — —<br>FX3GE-24MT/DS P P P — — — — — — FX2N-232IF P p — P P P P P P<br>FX3GE-24MT/DSS P P P — — — — — — FX2NC extension blocks<br>FX3GE-40MR/DS P P P — — — — — — FX2NC-16EX-T-DS P P P — P P — — —<br>FX3GE-40MT/DS P P P — — — — — — FX2NC-16EYR-T-DS P P P — P P — — —<br>FX3GE-40MT/DSS P P P — — — — — — FX2NC-16EX-DS P P P — P P — — —<br>FX3GC base units FX2NC-16EYT-DSS P P P — P P — — —<br>FX3GC-32 MT/DSS P P P — — — — — — FX2NC-32-EX-DS P P P — P P — — —<br>FX2NC-32-EYT-DSS P P P — P P — — —<br>**----- End of picture text -----**<br>
*LVD = Low Voltage Directive
P = comply, p = no need to comply
66
Certifications
**==> picture [513 x 456] intentionally omitted <==**
**----- Start of picture text -----**<br>
CE uL Ship approvals CE uL Ship approvals<br>Module type EMC LVD* cUL ABS DNV LR GL BV RINA Module type EMC LVD* cUL ABS DNV LR GL BV RINA<br>FX2NC special function modules Terminal blocks<br>FX2NC-1HC P p P — — — — — — TB-20S — p P — — — — — —<br>FX3U special function modules TB-20C — p P — — — — — —<br>FX3U-2HC P p P — — — — — — Accessories<br>FX3U-3A-ADP P p P — — — — — — ALPHA POWER 24 P P P — — — — — —<br>FX3U-4AD P p P — — — — — — FX-10DM-E P p — — — — — — —<br>FX3U-4DA P p P — — — — — — FX-20 P-E-SET0 P p — — — — — — —<br>FX3U-4AD-TC-ADP P p P P P P P P P FX-USB-AW P p — — — — — — —<br>FX3U-4AD-PT-ADP P p P P P P P P P FX-232AWC-H P p — — — — — — —<br>FX3U-4AD-PNK-ADP P p P — — — — — — FX2N-CNV-IF P p — P — — — — —<br>FX3U-4AD-PTW-ADP P p P — — — — — — FX2NC-CNV-IF P p — — P P — — —<br>FX3U-4AD-ADP P p P P P P P P P FX3U-1PSU-5V — — — — — — — — —<br>FX3U-4DA-ADP P p P P P P P P P FX3UC-1PS-5V — — — — P — — — —<br>FX3U-4HSX-ADP P p P P P P P P P FX3U-7DM P p — P P P P P P<br>FX3U-4LC P p P — — — — — — FX3U-7DM-HLD P — — — — — — — —<br>FX3U-CF-ADP P p P — — — — — —<br>P = comply, p = no need to comply<br>FX3U-2HSY-ADP P p P P P P P P P<br>FX3U-20SSC-H P p P — — — — — —<br>FX3U-485ADP-MB P p P — — — P P —<br>FX3U-232ADP-MB P p P — — — P P —<br>FX3U-ENET-ADP P p P — — — — — —<br>FX3U-ENET P p P — — — — — —<br>FX3U-CAN P p P P P P P P P<br>FX3U-64DP-M P p P — — — — — —<br>FX3U-64CCL P — P — — — — — —<br>FX3U-J1939 P p P P P P P P P<br>FX3U-1PG P p P — — — — — —<br>Adapter boards<br>FX2N-CNV-BD P p — — — — — — —<br>FX3G-1DA-BD P p — — — — — — —<br>FX3G-2AD-BD P p — — — — — — —<br>FX3G-8AV-BD P p — — — — — — —<br>FX3G-232-BD P p — — — — — — —<br>FX3G-422-BD P p — — — — — — —<br>FX3G-485-BD P p — — — — — — —<br>FX3U-232-BD P p — P P P P P P<br>FX3U-422-BD P p — P P P P P P<br>FX3U-485-BD P p — P P P P P P<br>FX3U-CNV-BD P p — P P P P P P<br>FX3U-USB-BD P p — P P P P P P<br>FX3S-CNV-ADP P p P — — — — — —<br>FX3G-CNV-ADP P p P — — — — — —<br>**----- End of picture text -----**<br>
*LVD = Low Voltage Directive
67
Index
## **A**
## **E**
## **S**
|**A**|**E**|**S**|
|---|---|---|
|Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12|Extension adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46|Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10|
|ALPHA 2 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br>24 V power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52<br>AS-Interface module AL2-ASI-BD . . . . . . . . . . . . . . . . . . . .12<br>Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53<br>GSM Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br>Interface Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br>Memory cassette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12<br>FX series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br>5 V power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52<br>24 V power supply unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52<br>Backup batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52<br>Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53<br>Connection terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51<br>Display modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54<br>Expansion adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br>Memory media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49<br>Programming cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53<br>Terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50<br>Terminal connection cable . . . . . . . . . . . . . . . . . . . . . . . . . .51<br>Analog Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br>Analog input modules . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br>Analog I/O adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br>Analog output modules . . . . . . . . . . . . . . . . . . . . . . . . 33<br>Analog temperature input adapters . . . . . . . . . . . . . . 35<br>Analog temperature input modules . . . . . . . . . . . . . . 34<br>Combined analog I/O modules . . . . . . . . . . . . . . . . . . 34<br>**B**|Analog adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46<br>Analog setpoint adapter . . . . . . . . . . . . . . . . . . . . . . . . 47<br>Communications adapter . . . . . . . . . . . . . . . . . . . . . . . 47<br>Digital extension adapter . . . . . . . . . . . . . . . . . . . . . . . 46<br>FX3G-CNV-ADP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br>FX3S-CNV-ADP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br>FX3U-CNV-BD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47<br>Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br>Extension Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br>Analog extension modules ALPHA 2 . . . . . . . . . . . . . . 11<br>Digital extension modules ALPHA 2 . . . . . . . . . . . . . . 11<br>**H**<br>High-speed counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br>Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br>Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37<br>**I**<br>Interface adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br>Interface modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br>FX2N-232IF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br>FX3U-232ADP-MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br>FX3U-485ADP-MB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br>**M**<br>Modular extension units . . . . . . . . . . . . . . . . . . . . . . . . . . 31|Alpha 2 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br>FX3GC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br>FX3GE series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br>FX3G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br>FX3S series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br>FX3UC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29<br>FX3U series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br>System Description ALPHA . . . . . . . . . . . . . . . . . . . . . . . . . .4<br>System Description MELSEC FX family . . . . . . . . . . . . . . . . .4<br>Calculation of the power consumption . . . . . . . . . . . . . .7<br>Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6<br>Expandability and power . . . . . . . . . . . . . . . . . . . . . . . . .4<br>Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5<br>Sample calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7<br>**T**<br>Temperature control module . . . . . . . . . . . . . . . . . . . . . . 36<br>**U**<br>Unit components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br>ALPHA 2 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8<br>FX3GC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20<br>FX3GE series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br>FX3G series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br>FX3S series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br>FX3UC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27|
|Base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br>ALPHA 2 series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9<br>FX3GC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21<br>FX3GE series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br>FX3G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br>FX3S series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br>FX3UC series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28<br>FX3U Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24|**N**<br>Network modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39<br>for CANopen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br>FX3U-CAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43<br>for CC-Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39<br>FX2N-32CCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40<br>FX3U-16CCL-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39<br>FX3U-64CCL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39|FX3U series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23|
|**C**<br>Compact extension units . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br>**D**<br>Data logger module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br>Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br>Adapter modules FX3U . . . . . . . . . . . . . . . . . . . . . . . . . 58|for DeviceNet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br>FX2N-64DNET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43<br>for Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br>FX3U-ENET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40<br>FX3U-ENET-ADP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41<br>FX3U-ENET-P502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40<br>for J1939 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br>FX3U-J1939 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44||
|Adapters FX3G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60<br>ALPHA series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55<br>Display panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br>Extension blocks FX2N . . . . . . . . . . . . . . . . . . . . . . . . . 58<br>Extension blocks FX2NC . . . . . . . . . . . . . . . . . . . . . . . . 58<br>Function modules FX2N . . . . . . . . . . . . . . . . . . . . . . . . 59<br>Function modules MELSEC FX3U/FX3UC . . . . . . . . . . . 59<br>FX3G base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56<br>FX3GC base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br>FX3GE base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56<br>FX3S base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56<br>FX3U base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br>FX3UC base units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57<br>Memory cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br>Terminal blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60|for Profibus DP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br>FX2N-32DP-IF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42<br>FX2N-32DP-IF-D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42<br>FX3U-32DP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42<br>FX3U-64DP-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41<br>**P**<br>Positioning modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br>Positioning module for SSCNET . . . . . . . . . . . . . . . . . . 38<br>FX3U-20SSC-H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38<br>Single-axis positioning modules . . . . . . . . . . . . . . . . . 38<br>FX2N-10PG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38<br>FX3U-1PG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38||
68
Automation solutions
## **A world of automation solutions**
**==> picture [416 x 309] intentionally omitted <==**
**----- Start of picture text -----**<br>
Robots<br>Motion control and servos<br>iw<br>LV circuit protection Inverters<br>Laser machines<br>ee Pe, om<br>CNC<br>controllers<br>HMI and GOTs<br>ge: raceceneeeentt —<br>= ee"<br>- a |<br>EDM machines<br>Micro PLCs<br>Modular PLCs<br>**----- End of picture text -----**<br>
Mitsubishi Electric offers a wide range of automation equipment from PLCs and HMIs to CNC and EDM machines
## **A name to trust**
Since its beginnings in 1870, some 45 companies use the Mitsubishi name, covering a spectrum of finance, commerce and industry.
The Mitsubishi brand name is recognized around the world as a symbol of premium quality.
Mitsubishi Electric Corporation represents space development, transportation, semiconductors, energy systems, communications and information processing, audio visual equipment, home electronics, building and energy management and automation systems, and has 237 factories and laboratories worldwide in over 121 countries.
This is why you can rely on a Mitsubishi Electric automation solution – because we know first hand about the need for reliable, efficient, easy-to-use automation and control.
As one of the world’s leading companies with a global turnover of 4 trillion Yen (approximately $40 billion), employing over 100,000 people, Mitsubishi Electric has the resource and the commitment to deliver the ultimate in service and support as well as the best products.
19
## **Global partner. Local friend.**
**==> picture [511 x 203] intentionally omitted <==**
**----- Start of picture text -----**<br>
European Offices Representatives<br>Mitsubishi Electric Europe B.V. Germany Mitsubishi Electric Europe B.V. Russia GEVA Austria Beijer Electronics A/S Denmark Beijer Electronics SIA Latvia Sirius Trading & Services Romania I.C. SYSTEMS Ltd. Egypt<br>Gothaer Straße 8 52, bld. 3 Kosmodamianskaya nab 8 floor Wiener Straße 89 Lykkegardsvej 17 Ritausmas iela 23 Aleea Lacul Morii Nr. 3 23 Al-Saad-Al-Alee St.<br>D-40880 Ratingen RU-115054 Moscow A-2500 Baden DK-4000 Roskilde LV-1058 Riga RO-060841 Bucuresti, Sector 6 EG-Sarayat, Maadi, Cairo<br>Phone: +49 (0)2102 / 486-0 Phone: +7 495 / 721 2070 Phone: +43 (0)2252 / 85 55 20 Phone: +45 (0)46/ 75 76 66 Phone: +371 (0)6 / 784 2280 Phone: +40 (0)21 / 430 40 06 Phone: +20 (0) 2 / 235 98 548<br>Mitsubishi Electric Europe B.V. Czech Rep. Mitsubishi Electric Europe B.V. Spain OOO TECHNIKON Belarus HANS FØLSGAARD A/S Denmark Beijer Electronics UAB Lithuania INEA SR d.o.o. Serbia GIRIT CELADON Ltd. Israel<br>Radlická 751/113e Avenir Business Park Carretera de Rubí 76-80 Apdo. 420 Prospect Nezavisimosti 177-9 Theilgaards Torv 1 Goštautų g. 3 Ul. Karadjordjeva 12/217 12 H’aomanut Street<br>CZ-158 00 Praha 5 E-08190 Sant Cugat del Vallés (Barcelona) BY-220125 Minsk DK-4600 Køge LT-48324 Kaunas SER-11300 Smederevo IL-42505 Netanya<br>Phone: +420 251 551 470 Phone: +34 (0) 93 / 5653131 Phone: +375 (0)17 / 393 1177 Phone: +45 4320 8600 Phone: +370 37 262707 Phone: +381 (0)64 / 68 55 187 Phone: +972 (0)9 / 863 39 80<br>Mitsubishi Electric Europe B.V. France Mitsubishi Electric Europe B.V. (Scandinavia) Sweden ESCO DRIVES Belgium Beijer Electronics Eesti OÜ Estonia ALFATRADE Ltd. Malta SIMAP SK Slovakia CEG LIBAN Lebanon<br>25, Boulevard des Bouvets Fjelievägen 8 Culliganlaan 3 Pärnu mnt.160i 99, Paola Hill Jána Derku 1671 Cebaco Center/Block A Autostrade DORA<br>F-92741 Nanterre Cedex SE-22736 Lund BE-1831 Diegem EE-11317 Tallinn Malta-Paola PLA 1702 SK-911 01 Trenčín Lebanon-Beirut<br>Phone: +33 (0)1 / 55 68 55 68 Phone: +46 (0) 8 625 10 00 Phone: +32 (0)2 / 717 64 60 Phone: +372 (0)6 / 51 81 40 Phone: +356 (0)21 / 697 816 Phone: +421 (0)32 743 04 72 Phone: +961 (0)1 / 240 445<br>Mitsubishi Electric Europe B.V. Italy Mitsubishi Electric Turkey Elektrik Ürünleri A.Ş. Turkey KONING & HARTMAN B.V. Belgium Beijer Electronics OY Finland INTEHSIS SRL Moldova INEA RBT d.o.o. Slovenia ADROIT TECHNOLOGIES South Africa<br>Viale Colleoni 7 Palazzo Sirio Şerifali Mahallesi Nutuk Sokak No:5 Woluwelaan 31 Vanha Nurmijärventie 62 bld. Traian 23/1 Stegne 11 20 Waterford Office Park 189 Witkoppen Road<br>I-20864 Agrate Brianza (MB) TR-34775 Ümraniye-İSTANBUL BE-1800 Vilvoorde FIN-01670 Vantaa MD-2060 Kishinev SI-1000 Ljubljana ZA-Fourways<br>Phone: +39 039 / 60 53 1 Phone: +90 (0)216 / 526 39 90 Phone: +32 (0)2 / 257 02 40 Phone: +358 (0)207 / 463 500 Phone: +373 (0)22 / 66 4242 Phone: +386 (0)1 / 513 8116 Phone: + 27 (0)11 / 658 8100<br>Mitsubishi Electric Europe B.V. Ireland Mitsubishi Electric Europe B.V. UK INEA RBT d.o.o. Bosnia and Herzeg. PROVENDOR OY Finland HIFLEX AUTOM. B.V. Netherlands Beijer Electronics Automation AB Sweden<br>Westgate Business Park, Ballymount Travellers Lane Stegne 11 Teljänkatu 8 A3 Wolweverstraat 22 Box 426<br>IRL-Dublin 24 UK-Hatfield, Herts. AL10 8XB SI-1000 Ljubljana FIN-28130 Pori NL-2984 CD Ridderkerk SE-20124 Malmö<br>Phone: +353 (0)1 4198800 Phone: +44 (0)1707 / 28 87 80 Phone: +386 (0)1/ 513 8116 Phone: +358 (0) 2 / 522 3300 Phone: +31 (0)180 / 46 60 04 Phone: +46 (0)40 / 35 86 00<br>Mitsubishi Electric Europe B.V. Poland Mitsubishi Electric Europe B.V. UAE AKHNATON Bulgaria UTECO A.B.E.E. Greece KONING & HARTMAN B.V. Netherlands OMNI RAY AG Switzerland<br>ul. Krakowska 50 Dubai Silicon Oasis 4, Andrei Ljapchev Blvd., PO Box 21 5, Mavrogenous Str. Haarlerbergweg 21-23 Im Schörli 5<br>PL-32-083 Balice United Arab Emirates - Dubai BG-1756 Sofia GR-18542 Piraeus NL-1101 CH Amsterdam CH-8600 Dübendorf<br>Phone: +48 (0) 12 630 47 00 Phone: +971 4 3724716 Phone: +359 (0)2 / 817 6000 Phone: +30 (0)211 / 1206-900 Phone: +31 (0)20 / 587 76 00 Phone: +41 (0)44 / 802 28 80<br>INEA CR Croatia MELTRADE Kft. Hungary Beijer Electronics AS Norway OOO “CSC-AUTOMATION” Ukraine<br>Losinjska 4 a Fertő utca 14. Postboks 487 4-B, M. Raskovoyi St.<br>HR-10000 Zagreb HU-1107 Budapest NO-3002 Drammen UA-02660 Kiev<br>Phone: +385 (0)1 / 36 940 - 01/ -02/ -03 Phone: +36 (0)1 / 431-9726 Phone: +47 (0)32 / 24 30 00 Phone: +380 (0)44 / 494 33 44<br>AutoCont C.S. S.R.O. Czech Republic TOO Kazpromavtomatika Kazakhstan Fonseca S.A. Portugal<br>Kafkova 1853/3 Ul. Zhambyla 28 R. João Francisco do Casal 87/89<br>CZ-702 00 Ostrava 2 KAZ-100017 Karaganda PT-3801-997 Aveiro, Esgueira<br>Phone: +420 595 691 150 Phone: +7 7212 / 50 10 00 Phone: +351 (0)234 / 303 900<br>**----- End of picture text -----**<br>
**Mitsubishi Electric Europe B.V.** / FA - European Business Group / Gothaer Straße 8 / D-40880 Ratingen / Germany / Tel.: +49(0)2102-4860 / Fax: +49(0)2102-4861120 / info@mitsubishi-automation.de / https://eu3a.mitsubishielectric.com
Art. no. 167840-G / 02.2014 / Specifications subject to change / All trademarks and copyrights acknowledged.
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →