EVS36-16R7
POWER SUPPLY, AC-DC, 36V, 16.7A
- Manufacturer: TDK-LAMBDA
- Product type: AC / DC Enclosed Power Supplies
- Product Range: EVS Series
- No. of Outputs: 1Outputs
- Output Power Max: 600W
- Input Voltage VAC: 85V AC to 265V AC
- Power Supply Approvals: ITE
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 16.7A
- Output Voltage - Output 1: 36V
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 269.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
**EVS Series** **www.** emea.tdk-lambda.com/evs ## **300 and 600W Constant Current Power Supplies** ||**Features**||**Benefits**| |---|---|---|---| ||• 300W Convection cooled and 600W fan model • Silent fanless chargers|• 300W Convection cooled and 600W fan model • Silent fanless chargers|• 300W Convection cooled and 600W fan model • Silent fanless chargers| ||• CC (constant current) mode||• Quick recharge, avoid battery overcharging| ||• CV (constant voltage) mode||• Supports charging of 12, 24 and 48V batteries| ||• 5 Year warranty||• Provides high reliability for battery charger<br>and electrical storage system| ||||| |**Specification**<br>**Model**<br>**EVS300**<br>**EVS600**<br> Input Voltage<br>V<br>85-265VAC (47-63Hz)<br>85-265VAC (47-63Hz)<br>Input Current<br>A<br>3.6 / 1.8<br>7.2 / 4.0<br>Inrush Current (100/200VAC)<br>A<br>15 / 30<br>20 / 40<br>Power Factor (100/200VAC)<br>-<br>0.97/0.93<br>0.95/0.9<br>PFHC<br>-<br>Meets EN61000-3-2<br>Leakage Current<br>mA<br>< 0.5mA<br>< 0.75mA<br>Temperature Coefficient<br>%/°C<br><0.02%/°C<br>Constant Current Setting Accuracy<br>A<br>±10%<br>Overvoltage Protection<br>V<br>18V*: 19.8-23.4V, 36V: 39.6-46.8V, 57V: 62.7-74.1V (* EVS300 only)<br>Hold Up Time (Typ)<br>ms<br>10ms at 100/110VAC input<br>Efficiency (100/200VAC)<br>%<br>18V: 86/89%, 36V: 88/91%, 57V: 87/90%<br>36V: 85/88%, 57V: 84/87%<br>Remote On/Off<br>-<br>Optional<br>Series & Parallel Operation<br>-<br>Yes, see instruction manual<br>Operating Temperature<br>-20°C to +70°C -20°C to +70°C<br>(No external airflow)<br>°C<br>Derate linearly to 40% load from 45°C to 70°C<br>Derate linearly to 20% load from 50°C to 70°C<br>Operating Temperature<br>-20°C to +70°C -20°C to +70°C<br>External airflow (1.4m/s)<br>°C<br>Derate linearly to 70% load from 60°C to 70°C<br>Not applicable (EVS600 has internal fan)<br>Storage Temperature<br>°C<br>-30°C to +75°C<br>Humidity (non condensing)<br>%RH<br>Operating: 30 - 90%RH, Storage: 10 - 90%RH<br>Cooling<br>-<br>Convection or forced air<br>Internal fan<br>Withstand Voltage<br>VAC<br>Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.<br>Isolation Resistance<br>MΩ<br>>100MΩ at 25°C & 70%RH, Output to Ground 500VDC<br>Vibration (non operating)<br>-<br>10 - 55Hz (1 minute sweep), 19.6m/s2constant, X, Y, Z 1 hour each<br>Shock<br>-<br>< 196.1 m/s2<br>Safety Agency Certifications<br>-<br>UL60950-1, CSA60950-1, EN60950-1, CE Mark<br>Conducted & Radiated EMI<br>-<br>EN55011/EN55022-B, FCC Class B, VCCI-B<br>Immunity<br>-<br>EN61000-4-2, -3, -4, -5, -6, -8, -11; EN61000-6-2<br>Weight (Typ)<br>g<br>540g (open frame)<br>1600g<br>Size (WxHxD)<br>mm<br>84 x 42 x 180mm<br>120 x 61 x 190mm<br>Warranty<br>yrs<br>5<br>~~7~~|||| ||||EVS Series<br>1| **==> picture [517 x 34] intentionally omitted <==** |**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**|**Model Selector**| |---|---|---|---|---|---|---|---| |**Nominal**<br>**Adjust**<br>**Max**<br>**Max**<br>**Current Adjust**<br>**Current Adjust**<br>**CV Line**<br>**CV Load**<br>**Ripple &**<br>**Model**<br>**Voltage**<br>**Range**<br>**Current**<br>**Current**<br>**Range**<br>**Range**<br>**Reg**<br>**Reg**<br>**Noise**<br>**Output**<br>**(V)**<br>**(100VAC)**<br>**(200VAC)**<br>**(100VAC)**<br>**(200VAC)**<br>**(mV)**<br>**(mV)**<br>**(mV)**|||||||| |EVS18-16R7|18V|12 - 18V|16.7A||8.35 - 16.70A<br>72||<br>144<br>200| |EVS36-8R4|36V|24 - 36V|8.4A||4.20 - 8.40A<br>14||4<br>252<br>250| |EVS36-16R7|36V|24 - 36V|15.3A|16.7A|8.35 - 15.30A|8.35 - 16.70A<br>14|4<br>288<br>200| |EVS57-5R3|57V|48 - 57V|5.3A||2.65 - 5.30A<br>22||8<br>285<br>250| |EVS57-10R6|57V|48 - 57V|9.7A|10.6A|5.30 - 9.70A|5.30 - 10.60A<br>22|8<br>456<br>200| ## **Outline Drawing EVS300W Series** **==> picture [511 x 210] intentionally omitted <==** ## **Options** |**Suffx**|**Description**| |---|---| |-|None| |/A|Cover & L Bracket (Standard on EVS600)*| |/R|Remote On/Off| |Example|EVS57-5R3/RA| **Note:** * without suffix EVS Series 2 **==> picture [516 x 34] intentionally omitted <==** ## **Outline Drawing EVS600W Series** **==> picture [511 x 302] intentionally omitted <==** **----- Start of picture text -----**<br> H V.ADJ<br>OUTPUT :<br>+V 36 V<br>+V 16.7 A<br>-V<br>-VL Pollution Degree : 2 Use wires rating at least 75°C OUTPUT : 36 V<br>N Max. surrounding air temperature : 70°C EHFP 16.7 A 50-60Hz INPUT : 100-240VAC 7.0 A EVS 36 - 16R7<br>I.ADJH<br>**----- End of picture text -----**<br> **Accessory Description EVS-RP6020 20A Reverse current Prevention module for battery charging use (PCB type) * EVS-RP6020/L 20A Reverse current Prevention module for battery charging use (on L bracket) *** - **The Reverse current Protection modules EVS-RP can also be used as replacement for Diode-modules (as e.g. DLP-PU)** - For power up in parallel operation - For Back-up diode (N + I redundant operation) ## **Outline Drawing EVS-RP6020 (Open frame)** **==> picture [511 x 232] intentionally omitted <==** **----- Start of picture text -----**<br> INPUT VOLTAGE INPUT CURRENT : 0 - 20 A : 7 - 60 VDC EVS -RP6020/L<br>EHFP<br>**----- End of picture text -----**<br> EVS Series 3 **==> picture [517 x 34] intentionally omitted <==** ## **Outline Drawing EVS-RP6020/L Series** **==> picture [46 x 90] intentionally omitted <==** **==> picture [131 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> INPUT VOLTAGE INPUT CURRENT : 0 - 20 A : 7 - 60 VDC EVS -RP6020/L<br>EHFP<br>**----- End of picture text -----**<br> **==> picture [32 x 90] intentionally omitted <==** **==> picture [153 x 32] intentionally omitted <==** ## **Notes:** ~~A~~ : M3 embosse ~~d~~ tapped and countersink hole ~~s~~ (6) are for customer’s chassis mounting - B: ~~D~~ ia 3.5mm holes ~~(~~ 2) and R1.75 slot holes (2) are for customer’s ch ~~a~~ ssis mounting holes - C: Model name, i ~~n~~ put range and input cu ~~rr~~ ent are shown here in accordance with the specifications EVS -RP6020/L **INPUT VOLTAGE : 7 - 60 VDC INPUT CURRENT : 0 - 20 A** D: Country of manufacture will be shown here ## **Accessorie** ~~**s**~~ **:** - Terminal cover for barrier terminal strip –––2 (attached on terminal TB ~~1~~ an ~~d~~ TB2 at shipment) EHFP EVS Series 4 ## **TDK-Lambda France SAS** 3 Avenue du Canada Parc Technopolis Bâtiment Sigma 91940 les Ulis France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com ## **Italy Sales Office** Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com ## **TDK-Lambda UK Ltd.** Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com ## **TDK-Lambda Ltd.** Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 info@tdk-lambda.co.il www.tdk-lambda.co.il ## **Netherlands** info@nl.tdk-lambda.com www.nl.tdk-lambda.com ## **TDK-Lambda Germany GmbH** Karl-Bold-Strasse 40 77855 Achern Germany ## **C.I.S.** **Commercial Support:** Tel: +7 (495) 665 2627 **Technical Support:** Tel: +7 (812) 658 0463 info@tdk-lambda.ru www.tdk-lambda.ru Tel: +49 7841 666 0 Fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com ## **Local Distribution** Ce ## **Austria Sales Office** Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 info@at.tdk-lambda.com www.de.tdk-lambda.com ## **Switzerland Sales Office** Bahnhofstrasse 50 8305 Dietlikon Switzerland Tel: +41 44 850 53 53 Fax: +41 44 850 53 50 info@ch.tdk-lambda.com www.de.tdk-lambda.com ## **Nordic Sales Office** Haderslevvej 36B DK-6000 Kolding Denmark Tel: +45 2911 9556 info@dk.tdk-lambda.com **www.emea.tdk-lambda.com** EVS Series Oct16 v5 EVS Series 5
Updated at February 9, 2023
TDK-Lambda is globally recognized as a premier manufacturer of highly reliable power supply solutions and power management equipment. With a strong engineering heritage, the company is a trusted partner for mission-critical applications across the industrial, medical, telecommunications, and test and measurement sectors, delivering components that meet stringent international performance and safety standards. Our extensive portfolio of TDK-Lambda products is heavily focused on comprehensive power and line protection, highlighted by a vast selection of industry-leading AC/DC converters. Engineered to deliver exceptional efficiency and stable performance in demanding environments, these power supplies form the backbone of our offering and are built to support the rigorous power demands of modern electronic infrastructure. To complement these primary power solutions, we also offer a targeted range of high-performance DC/DC converters designed for precise, board-level voltage regulation. Furthermore, to ensure the optimal performance and longevity of these power systems, our catalog includes specialized cooling and thermal management components, such as natural convection heat sinks, providing complete thermal stability for your most critical designs.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →