ETC1311-FE-SM7
Thermostat, ETC1311 Series, J Type Thermocouple, 9 to 30 Vdc, 8A Relay Output
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CAL CONTROLS
- Product type: Temperature Controllers
- Thermocouple Type: J
- Output Voltage Max: 250VAC
- Operating Temperature Max: 50°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 25 |
| Price | 55.77 € |
| Current stock | 10+ |
| Lead time | 30 days |
Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. CAL Controls shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. ## **CAL ETC1311 DIGITAL THERMOSTAT** Thank you for choosing the CAL ETC1311 thermostat. - **34 x 77mm sized.** > *** On-Off control.* J type Thermocouple or Pt100 input.* Temperature compensation.** C ~~E~~ **OUT °C * In the case of probe failure, heating can be selected on, off or periodical running. PRG * Upper and lower limits of the setpoint can be** > **adjusted.** a.BV *** Set value can be adjusted by using single key.** CAL **ETC1311 * CE marked according to European Norms. Order Code : 1 2 3 1 - Input 2 - Supply Voltage 3 - Output** FE.....J Type 230VAC...230V AC P..........Relay-16A R.......Pt100 24VAC.....24V AC None...Relay-8A 12VAC.....12V AC SM...........9-30V DC SMPS - **Temperature compensation.** - **In the case of probe failure, heating can be selected on, off or periodical running.** - **Upper and lower limits of the setpoint can be adjusted.** - **Set value can be adjusted by using single key.** - **CE marked according to European Norms.** ## **Order Code :** ## **Connectýon Dýagram** CAL ETC1311 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The electrical connections must be carried out by qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components. **==> picture [364 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> ETC1311-FE-230VAC eas tc www.cal-controls.com sien ETC1311-FE-230VAC-Pwww.cal-controls.com ssa ETC1311-R-12VACwww.cal-controls.com<br>DIGITAL THERMOSTAT DIGITAL THERMOSTAT DIGITAL THERMOSTAT<br>SN: XXXXXXXXX SN: XXXXXXXXX SN: XXXXXXXXX<br>J (Fe-CuNi) J (Fe-CuNi)<br>Pt100<br>A A<br>- + - +<br>1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12<br>oh ee oh ea<br>HEAT OUT 250V AC 8A RESISTIVE LOAD HEAT OUT 240V AC 16A RESISTIVE LOAD HEAT OUT 250V AC 8A RESISTIVE LOAD<br>3VA 3VA 3VA<br>230V AC +10% -20% 50/60Hz 230V AC +10% -20% 50/60Hz 12V AC ±10% 50/60Hz<br>**----- End of picture text -----**<br> **Equipment is protected throughout by DOUBLE INSULATION. Holding screw 0.4-0.5Nm** **==> picture [355 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> NOTE: Fuse<br>Note:<br>SUPPLY: F 100 mA<br>250V AC Switch 1) Mains supply cords shall meet the requirements of<br>a 184-253V AC50/60Hz 3VA 45 << NeutralLine 230V ACSupply 2) In accordance with the safety regulations, the powerIEC 60227 or IEC 60245.supply switch shall bring the identification of the<br>. Ar ae Fuse shouldbe connected Cable size: 1,5mm² relevant instrument and it should be easilyaccessible by the operator.<br>**----- End of picture text -----**<br> ## **Technical Specifications** **ENVIRONMENTAL CONDITIONS Ambient/storage temperature 0 ... +50°C/-25 ... 70°C (with no icing)** SSSa **Max. relative humidity** | **80%, up to 31°C decreasing linearly 50% at 40°C Rated pollution degree According to EN 60529 Front panel : IP60** —— **Rear panel : IP20** a **Height** | **Max. 2000m** . ”.” **Do not use the device in locations subject to corrosive and flammable gasses. ELECTRICAL CHARACTERISTICS Supply voltage 230V AC +%10 -%20, 50/60Hz or 12VAC or 24 AC** ± **%10, 50/60Hz or optional 9-30V DC** ± **%10 . Power consumption Max. 3VA Wiring 2.5mm² screw-terminal connections. Scale 0 .... +600°C for J Type. -100.... +600°C for Pt100 Accuracy ± 0.5% (of full scale) ±1 digit Indicator 3 digits, 14mm, 7 parts red LED EMC EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests. The device is designed to operate in controlled electromagnetic environment) Safety requirements EN 61010-1: 2001 (Pollution degree 2, overvoltage category II) OUTPUT HEAT OUT For ETC1311-XX-XX ; Relay: 250V AC, 8A(for resistive load), NO+NC. For ETC1311-FE-XXP ; Relay: 240V AC, 16A(for resistive load), NO. Life expectancy for relay For ETC1311-XX-XX ; Mechanical 30.000.000; Electrical 100.000 operation. For ETC1311-FE-XXP ; Mechanical 30.000.000; Electrical 30.000 operation. CONTROL Control type Single-setpoint control Control algorithm On-Off control Hysteresis Adjustable between 1 ... 20°C. HOUSING** **Housing type Suitable for panel mounting.** ~~a~~ **Dimensions W77xH34xD70mm** ~~a~~ **Weight Approx. 250g (after packing the device and a probe)** a **Enclosure material Self extinguishing plastics** **==> picture [373 x 242] intentionally omitted <==** **----- Start of picture text -----**<br> While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.<br>Dimensions<br>Depth<br>85mm For removing mounting clamps: 70mm 8mm .<br>OUT | ———_ 4<br>°C Push out the mounting clamp<br>in direction 1 as shown<br>PRG in the figure below. Then, pull mol Te<br>out the clamp in direction 2.<br>CAL ETC1311<br>ee mounting mounting — 2 Panel 4 Rubber<br>clamp clamp gasket<br>g (<br>1<br>Panel cut-out Note :1) Panel thickness<br>VaSisUUULUssisisisi_)V Ty“ py — 71mm should be maximum<br>7 mm.<br>2) If there is no 60mm<br>free space at the back<br>side of the device, it<br>BIO | would be difficult toremove it from the<br>Lo Panel<br>CAL CONTROLS LTD<br>—— Bury Mead Road, Hitchin, Herts, SG5 1RT, UK.<br>Tel : +44 (0) 1462 436161 Fax : +44 (0) 1462 451801<br>e-mail: sales@cal-controls.co.uk Web : www.cal-controls.com<br>29mm<br>34mm<br>50/60Hz<br>3VA 8 A 250V AC 250V AC 8A HEAT OUTCOMPRESSOR<br>230V AC +10% -20% RESISTIVE LODCos= 1 1/2HP 240V AC Cos<br>= 0.4<br>www.cal-controls.com<br>12 11 10 9 8 7 6 5 4 3 2 1<br>+ -<br>J (Fe-CuNi)<br>XXXXXXXX SN:<br>DIGITALT THERMOSTAT<br>ETC1311-FE-230VAC<br>**----- End of picture text -----**<br> **1/2** **ETC1311-E-06** **==> picture [764 x 514] intentionally omitted <==** **----- Start of picture text -----**<br> HEATING OUT<br>LED Displayed process value in the run mode, parameter name or value in programming mode.<br>OUT Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for<br>°C increasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.<br>PRG<br>Used for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing<br>CAL ETC1311 the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.<br>Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode.<br>While holding a key, setpoint value of the selected parameter appears and by using A and Vv keys the value can be adjusted.<br>Run mode<br>Process If no key is pressed<br>1000 100 Value 200 199 200 for 3 seconds<br>When pressed Va or key, temperature set value flashes and by using A and Y keys the value can be adjusted.<br>If no key is pressed for 3 seconds run mode is returned.<br>+y—-[i -y—_ i —- .—_-_ :<br>If key is pressed and held for 3 seconds, If . key is pressed,<br>programming mode is entered. run mode is entered.<br>| Programming Mode TT PARAMETER TABLE<br>Con Menu of Configuration parameters MIN MAX UNIT DEF.SET<br>Con SeC<br>[4 g Se Hys Switch hysteresis for the setpoint. (When temperature 1 20 °C 1<br>. = Upl The upper limit of the setpoint.falls to SET-HYS, output relay becomes active.) LoL 600 °C 600<br>Switch hysteresis Access code for menu of security.<br>Hys for the setpoint. Cod Enter 311 then press key. LoL The lower limit of the setpoint. Fe-CuNi 0 UPL °C 0<br>= : - eea Pt100 oe -99 UPL °C -99<br>Eon In the case of error, on time rate of the relay output. 0 100 % Ect 0<br>Vv Vv a<br>The upper limit Security parameter for menu of configuration. Ect In the case of error, period of the relay output. 10 250 sec 30<br>Upl of the setpoint. Aco Non= Menu is invisible. E oFs Offset value. -99 99 °C 0<br>Pye= Parameters of menu are changeable.<br>Pno= Parameters of menu are only visible. SEC Menu of Parameter security<br>=<br>Aco Security parameter for menu of configuration.<br>The lower limit Security parameter for temperature set value. Non= Menu is invisible.<br>Lol of the setpoint. Ase PyePno= Set value is only visible.= Set value is changeable. PyePno== Parameters of menu are only visible.Parameters of menu are changeable.<br>= - —<br>ASE Security parameter for temperature set value.<br>Eon In the case of error,on time rate of Pye= Set value is changeable.<br>the relay output. Pno= Set value is only visible.<br>- pp<br>In the case of error, Error Messages<br>Ect period of ---<br>= the relay output. Means, temperature value is higher than the scale.<br>Vv<br>OoFs Offset value ___ Means, temperature value is lower than the scale.<br>_<br>Vv Pfa Means, temperature sensor is broken or over temperature.<br>PRG<br>PRG PRG<br>**----- End of picture text -----**<br> **ETC1311-E-06** **2/2**
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →