EPP-LKKEY
Circuit Breaker Accessory, ABB Protecta Plus Series MCB Distribution Boards, Lock and Key
- Manufacturer: ABB
- Product type: Circuit Breaker Accessories
- For Use With:ABB Protecta Plus Series MCB Distribution Boards; Accessory Type:Lock and Key; Product Range:Protecta Plus Series; SVHC:No SVHC (15; Available until stocks are exhausted
- SVHC: To Be Advised
- For Use With: ABB Protecta Plus Series MCB Distribution Boards
- Product Range: Protecta Plus
- Accessory Type: Lock and Key
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 25.4 € |
| Current stock | 10+ |
| Lead time | 30 days |
**—** PRODUCT OVERVIEW
## **Protecta Plus** MCB distribution board 250A Edition 1
2
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
**— Our electrical distribution solutions upgrade power in buildings to create safer, more energy efficient and more productive environments, enabling our customers and their customers to do more with less.** eee | ee ' pore eeehy
TABLE OF CONTENTS
3
## **— Table of contents**
**004** – 009 **Introduction to Protecta Plus 010** – 021 **Key modular components 022** – 047 **Ordering codes 048** – 073 **Technical information 074** – 075 **Glossary**
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
4
## **—**
## **Protecta Plus** General features of the series
With the new Protecta Plus system, ABB has developed a new and personalised series of MCB distribution boards which can be expanded over time. The wide internal accessibility ensures a quick and easy approach to the electrical components assembly. The neutral and earth bars positioned on the inner sides of the distribution board are completely isolated to ensure better safety for users.
## **Main construction features**
- Structure in epoxy coated metal sheets, 1 mm, textured finish
- Wall installation for indoor environments
- Degree of protection - IP43 with door, IP30 without door
- Mechanical resistance: IK07
- Busbar rating: 250A
## **Ease of wiring**
With the new mounting concept, Protecta Plus offers great levels of flexibility and accessibility for installation and wiring. The internal module can be easily removed allowing the wiring of different equipment outside the distribution board. This solution allows for an easier installation with more rapid production times.
- Number of ways: 4, 8, 12, 16, 20, 24
- Maximum ambient temperature +35 °C
- Compliance with IEC BS EN 61439 1-2
- Simple wiring of all cabinets, both horizontally and vertically
- Easy internal accessibility that facilitates all the wiring operations and maintenance
- Prepackaged standardized kits for specific applications (e.g. surge protection, metering)
## **Maximum accessibility**
Thanks to the particularly large opening angle of the door, Protecta Plus offers the possibility to have optimal access to the distribution board, especially in case of maintenance. The perfectly reversible doors can be installed with right or left opening.
## **A comprehensive range**
The range consists of distribution boards for wall mounting in six heights from 590 mm to 1360 mm, 450 mm width and depth starting from 125 mm, ensuring the development of multiple solutions. Protecta Plus system is easy to design, quick to assemble and reliable to apply.
PROTECTA PLUS – GENER AL FE ATURES OF THE SERIES
5
## **—**
A series of rational solutions developed to achieve a complete range of capabilities and functions with a single type of distribution board to meet different installation requirements, whilst simplifying the work of the installer.
## **Simplified series**
## **connection**
The distribution boards can be combined side-byside through pre-cut cable conduit holes large enough for the passage of wiring harnesses.
## **Range**
depth: 125 mm; width: 450 mm; 6 heights: 590, 730, 870, 1050, 1220, 1360 mm.
**Ergonomics and design** The design of this series is characterized by special features, such as rounded edges for a more efficient ergonomic look.
**High output capacity** Primary branch capacity up to 100A.
**Complete Flexible mounting protection** ——— | The PAN assembly Designed to ensure system can easily be maximum removed from the protection and | suit bottom distribution efficiency, through board of the the prevision for the framework, ensuring installation of surge quick and simple protection devices installation. and counters.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
6
## **—**
## **Protecta Plus**
## The details make the difference
## **Board width**
Protecta Plus has been designed with a width of 450 mm, this combined with the reduced RCBO height of 115 mm gives the installer ample cable room either side of the board.
## **One Solution**
All Protecta Plus boards come as standard with 250A main bars. This gives the user a full range from 125A 3P through to 250A 4P incoming options.
## **Incoming shroud**
The shroud comes ready to accept a 125A 3P incoming devices. The easy break technology and clear indication on the rear allows the user to modify the shroud dependant upon requirements up to 250A 4P.
## **100A Outgoing ways**
The first two 3P outgoing ways are fitted with 3 mm branch copper to allow for 100A MCBs to be fitted. This allows for a maximum of **2 x 100A 3P or 6 x 100A 1P** MCBs per board removing the need to move up to high performance boards or panel boards.
PROTECTA PLUS – THE DETAILS MAKE THE DIFFERENCE
7
## **Full MCB blank**
To aid installation and safety a custom MCB blank has been developed specifically for Protecta Plus.
## **Padlocking facilities**
All outgoing devices on Protecta Plus can be padlocked in on/off position for increased safety.
## **Clean earth**
Earth bars are fitted with removable links allowing the boards to be configured for 50/100% clean earth.
## **Metering and surge protection**
Available in kit form to fit all Protecta Plus TPN boards. The boards have been designed to house these integrally.
**==> picture [5 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
8<br>**----- End of picture text -----**<br>
**==> picture [199 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
PROTECTA PLUS MCB DISTRIBUTION BOARD 250A<br>**----- End of picture text -----**<br>
**—** ‘_ + — a PROTECTA PLUS a " & , ) at " Say ay — ve = a ' = . = 2 He ; 7 = The wide internal accessibility ensures >| as vie, a 4 1 “tn = a quick and easy approach to the electrical components assembly.
ci ’ 4 = “ Circuit monitoring systems (CMS) is a unique ultra-compact and V4 a high-performance multichannel i a 5 } 4 1 . ) gs measurement system for branch monitoring power r '
9
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
10
## **—**
## **Key modular components - MCB S 200** State-of-the-art safety
**==> picture [514 x 420] intentionally omitted <==**
**----- Start of picture text -----**<br>
Twin terminal<br>for separate IP20<br>finger safety.<br>feeding of busbar<br>and conductor.<br>—— s<br>i"<br>Easy identification<br>of the product and<br>highly resistant 4 Save your time<br>all important data<br>laser marking.<br>available right<br>iS 203 Pm | anh za | away.<br>Easy product name,<br>easy identification. aes he °<br>Quick identification<br>thanks to laser printed<br>EAN marking.<br>Contact position<br>——_—r ; 6<br>indication | 1<br>wally O *|<br>a . Captive screws<br>a don’t loose what’s<br>important to you.<br>**----- End of picture text -----**<br>
KEY MODUL AR COMPONENTS - MCB S 200 – STATE- OF-THE-ART SAFET Y
11
## **Contact position indication**
All System pro M compact® MCBs are equipped with a contact position indication (CPI) on the toggle. You can easily identify, if the MCB is in the ON or OFF position – easy and safe maintenance work is possible.
## **Locking device for MCBs and RCBOs**
Preventing unauthorised or dangerous operation of the operating lever. An adaptor makes it possible to block the operating lever whether switched ON or OFF. The lever is blocked with a padlock having a cross bar section of 3 mm or, as the case may be, 6 mm max. For multi-pole devices, one lock may be fitted per pole.
## **Approvals printed on the dome**
S 200 MCBs comply with IEC/EN 60898-1 and IEC/EN 60947-2 , as well as carrying the relevant approval marks for the markets they are designed for. Certification markings are printed on the dome of the MCB, making it possible to see the markings when mounted.
## **IP 20 - finger safe terminals**
The System pro M compact® MCBs are equiped with 35 mm² + 10 mm² cylinder lift twin terminals, a well proven and reliable technology - designed for sopisticated industrial use.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
12
## **—**
## **Key modular components - DSE201 M** Compact design, enhanced protection
## **Space for insulated screwdrivers**
Equipped with cage type terminals (16 mm² load side), with tightening torque of 1.2 Nm.
## **Easy to install**
Fast installation is supported by the two flying leads for neutral cable and functional earth, each integrated in the device, which can be directly connected to the main neutral and earth bars.
## **In control**
A test button allows the regular check of the functionality of the device: to be pushed every six months.
**Earth fault indicator** ~~=~~ Blue window in the front of the device to detect any earth fault trip: the cause of trip of the device can be identified in a short time, reducing the downtime for maintenance.
**Combination with auxiliary elements** New platform suitable for quick installation in combination with the standard auxiliary elements that can be mounted with RCDs and MCBs.
## **Anti-counterfeiting**
Equipped with an RFID tag containing a unique serial number assigned by ABB in accordance to ISO/IEC FCD 15693-3 standard in order to authenticate the product.
**Real contact position indicator below the toggle**
Directly linked to the moving contact of the device, the green/red window in the front of the device can identify the current position of the contacts (open/closed) independently on the toggle position.
## **Reduced height**
Thanks to its reduced height, only 115 mm, DSE201 M makes for easier wiring operation inside the consumer unit or the distribution.
KEY MODUL AR COMPONENTS - DSE201 M - COMPACT DESIGN, ENHANCED PROTECTION
13
## **—**
With its breaking capacity of 10/15kA in only one module width and 115 mm height, DSE201 M series is the perfect solution for a complete protection in commercial and industrial applications, where space optimization is required.
## **Device status at a glance**
Earth fault indicator: blue window above the toggle to immediately detect and identify any earth fault trip, reducing downtime for maintenance. Contact position indicator (CPI): green/red window below the toggle to identify the real position of the contacts independently on the toggle position.
## **Double slot terminal**
Easy to install, , fail-safe line side, terminal to avoid improper connection. Two slots of different dimensions (35 mm[2] and 10 mm[2] ) available to allow the connection both with cables and busbars.
## **Load side**
The load side terminal accepts cables, both rigid and flexible up to 16 mm[2] . Flying leads are straight instead of pigtail ones to reduce the space required for wiring operations.
## **Easy and flexible**
Double and bistable clips with a new design for a secure fixing in any type of consumer unit or distribution board. Easy removal from a cluster of RCBOs/MCBs supplied with busbars.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
14
## **—**
## **Key modular components** A complete range for your surge protection
**Standard pro M terminals** Designed for a better coordination with the complete ABB System pro M compact® modular range.
## **Auxiliary Contact**
Possibility to add an auxiliary contact on the OVR Plus range with the standard ABB option.
**Clear information** On the front of the product indicating the technical characteristics of the OVR product.
## **End-of-life indicator**
The end-of-life indicator of the SPD signals the status of the device. Turning from green to red when the SPD reaches the end of its life. The optional safety reserve system has a partial-release mechanism, which provides a pre-failure warning.
KEY MODUL AR COMPONENTS - OVR PLUS - A COMPLETE R ANGE FOR YOUR SURGE PROTECTION
15
## **Complete coordination**
The bi-directional cylindrical terminal block of the OVR Plus range allows a complete coordination with the ABB range with considerable time savings in wiring operations. All the devices allow connection through busbars, both from above and from below.
## **Pluggable feature**
The pluggable feature of ABB OVR T1-T2, T2 and T2-T3 surge protective devices (SPDs) facilitates maintenance. Should one or more worn cartridges need to be replaced, the electrical circuit does not have to be isolated nor do the wires have to be removed.
**==> picture [90 x 83] intentionally omitted <==**
**----- Start of picture text -----**<br>
PLEASE ail L2 a La<br>=<br>_<br>GREEN. SUPPLY = PROTECTION<br>PROTECTION<br>IMAGE<br>GREEN & RED... REDUCED<br>RED wr NO PROTECTION<br>**----- End of picture text -----**<br>
## **Furse option for critical installations**
The Furse ESP 415 CD40 provides continuous operation of sensitive electronic systems in lightning intense environments, offering market-leading levels of protection, making it ideal for high-end applications, such as hospitals, data centres and automated process control systems.
## **Active status indication**
The Furse ESP 415 CD40 offers three way LED status indication, showing full, reduced and no protection. It also notifies the user of loss of phase, loss of power and warning of excessive volts between N-E.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
16
## **—**
## **Key modular components - Energy metering** Advanced energy performance analysis
> — Requirements for a deliberate strategy to manage 01 Modern sub-metering increases and control energy consumption are having an
> energy efficiency increasing impact on commercial buildings such and saves money by fair and accurate as shopping centers, offices, hotels and airports. cost distribution.
Electricity meters in commercial buildings are usually acquired by the property owner and read automatically via a facility or building management system. Just like for private property, modern sub-metering solutions can increase energy efficiency in commercial buildings and make considerable savings.
## **MID approval facilitates problem-free cost distribution**
Meters that are MID approved have the advantage of a certified and verified metering accuracy. This is important if discussions on the fairness of the cost distribution arise.
EQ meters can easily help distribute consumption costs between different tenants, e.g. stores and boutiques in shopping malls, businesses in office blocks, or different airlines and functions (baggage handling, for example) at airports.
## **Mandatory energy declarations**
Commercial properties must have an energy declaration that describes the building’s energy performance. Its aim is to reduce the climate effect and increase the efficient use of energy, i.e. benefits for both society and the building owner.
Energy declarations require that the electrical consumption for lighting, elevators, heating and ventilation, etc., be accounted for separately. Data collected from individually-located meters (sub-metering) are extremely valuable in this respect. As well as being a legal requirement, it highlights ways to increase efficiency by locating unnecessary energy consumption.
## **ISO 50001, L2 building regulations, BREEAM and others**
Whichever you aim for, analyzing energy consumption is an important early step and in the end also the best way to maintain an achieved level. EQ meters will provide accurate information regarding the electrical energy consumption.
## **Max demand also cuts energy consumption***
The fact that many commercial properties are not designed from the beginning for sub-metering presents no problem. EQ meters fit neatly wherever they are needed.
Measuring the highest average power during a set time interval results in the max demand value. Measuring max demand helps dimension a building’s electrical installations to its use.
— 01
KEY MODUL AR COMPONENTS - ENERGY METERING
17
—
The EQ series are meters for single phase and three phase metering. The EQ series meters are mounted on a DIN rail and are suitable for installation in distribution boards and small enclosures such as consumer units.
—
02
> — The EQ series are suitable in applications where 02 EQ series meters there is a need for reliable energy measurements and where space is limited.
## **General features**
The EQ series meters are versatile meters for many applications and installations. Navigating the meter is easily done via the push-buttons below the display. To configure the meter settings, the set button must be accessed and this button is protected against unauthorized use when the transparent lid on the front of the meter is closed and sealed. The power consumption of the meter is very low, less than 0.8 VA.
## **Communication***
Data from the EQ series meters can be collected via pulse output or serial communication. The pulse output is a solid state relay that generates pulses proportionally to the measured energy. The meters can also be equipped with built-in serial communication interfaces for M-Bus or Modbus (RS-485).
## **Inputs and outputs***
The EQ series support two inputs and two outputs in a fixed configuration. Inputs can be used for counting pulses from e.g. a water meter, or reading status from external devices. Outputs can be used as pulse outputs or controlling external apparatus like a contactor or an alarm (connected via an external relay).
## **Approvals***
The EQ series meters are type approved according to IEC and they are both type approved and verified according to MID. MID is the Measuring Instruments Directive 2004/22/EC from the European Commission. MID type approval and verification is mandatory for meters in billing applications within EU and EEA. The type approval is according to standards that covers all relevant technical aspects of the meter. These include climate conditions, electromagnetic compatibility (EMC), electrical requirements, mechanical requirements and accuracy.
* Dependant upon EQ Series metal selected
## **Instrumentation***
The EQ series meters support reading of instrument values. A large number of electrical properties can be read. Depending on version of the meter the following data is available:
- Active power
- Apparent power
- Reactive power
- Current
- Voltage
- Frequency
- Power factor
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
18
## **—**
## **Key modular components - CMS** Circuit monitoring systems
> —01 CMS-600 **CMS bus interface** — 02 Connection
> technology Control Unit.
A bus interface allows up to 96 sensors to be connected to the Control Unit.
— 03 Double slot terminal
—
04 CMS sensors
## **Control Units**
The Control Unit is a kind of computing and communication center that, depending on the equipment connected to it, evaluates the different data picked up by the sensors and makes it available via the built-in interfaces. \\\\KOOL ot cee
**Serial interfaces** Depending on the unit, numerous interfaces and protocols are available to ensure smooth network implementation: RS485 (Modbus RTU), LAN (TCP/IP and Modbus TCP).
Thanks to the built-in web server, an internet browser or a free Android or iOS app can be used to visualize the values measured. What’s more, the measured values can also be exported to CSV files.
19
KEY MODUL AR COMPONENTS - CMS - CIRCUIT MONITORING SYSTEMS
## **—**
The quality of a Circuit Monitoring System is dependent on the strengths of the individual components and how well they interact. ABB’s CMS sets the bar particularly high. Regardless of whether we’re talking compactness, technology, measurement results, user friendliness or flexibility, every component and every feature of this CMS has been fully optimized in terms of practicality and functionality.
## **Connection technology**
Connecting the sensors to the Control Unit is extremely simple and requires no special tools. All sensors are connected to the Control Unit by means of a flexible flat cable and insulation displacement connectors. The positioning of sensors is fully customizable so that they sit exactly where a measurement is required.
## **Sensors**
The CMS sensors form the heart of the system and they can be mounted anywhere without any problem. Initializing the sensors is also child’s play, with the desired identifier being assigned to each individual sensor via the control unit in just a few simple steps. The entire configuration and commissioning procedure takes just a matter of minutes. All measurement functions are available immediately following initialization.
**==> picture [421 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
— — — —<br>01 02 03 04<br>**----- End of picture text -----**<br>
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
20
## **—**
## **Key modular components - ABB i-bus® KNX** Intelligent building solutions
> — In many areas of our private and working lives, 01 The conventional solution: Many the increasing level of automation is a trend that
> separate cables, confronts us on a daily basis without actually separate functionality, little flexibility being noticed.
—
—
02 The intelligent solution: KNX – a system, a standard, with many interoperable functions for maximum flexibility
Automation in buildings aims to combine individual room functions with one another and to simplify the implementation of individual customer preferences.
KNX is the logical development for implementing traditional and new requirements in electrical building installations, replacing conventional installation techniques.
The intelligent installation bus system efficiently performs the conventional functions and offers an additional broad range of expanded features, which could not be realized without a bus system.
ABB offers consultants, system integrators and electrical installers a comprehensive product range with ABB i-bus® KNX, in order to meet the challenges posed to electrical building installations both today and in the future. Further information:
**http://www.abb.com/knx**
## **Intelligent Building Solutions with ABB i-bus® KNX ensure:**
- The right light in every situation by switching, dimming and controlling lights
- Visual protection and protection against sunlight by drive control of rolling shutters and blinds
- The right room temperature in every room by heating and cooling control
- The right air quality by controlling ventilation and climatization
- Automatic functions controlled by timer, movement, presence or meteorological data
- Security by monitoring operating conditions, signaling technical faults, recognizing hazards and triggering alarms
- Everything under control by visualization and manual operation
—
01
— 02
Actuators (command recipients) se hk 230 V KNX bus LG] Fa LJLo¢ ~~&~~ Sensors EOP (issue commands)
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
22
## **—**
## **Protecta Plus** Order process
**==> picture [447 x 466] intentionally omitted <==**
**----- Start of picture text -----**<br>
Protecta Plus DB Vertical split-load board Horizintal split-load board<br>Wee Se et f<br>Incoming kit<br>| 2 x Distribution boards |<br>ah ee =<br>Ce<br>Meter/surge kits (optional) Surge kits (optional) Surge kits (optional)<br>a Lo<br>\ ue 255<br>MCB/RCBO/Blanks<br>Accessories<br>**----- End of picture text -----**<br>
23 **— —** ABB I-BUS® KNX **—** PROTECTA PLUS _—— => / = **Protecta Plus** In many areas of our private and Protecta Plus gives UK installers **Order Codes** working lives, the increasing level and designers the flexibility to of automation is a trend that cover all applications through confronts us on a daily basis ee, standard and customised ' without actually being noticed.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
24
## **—**
## **Protecta Plus** Order Codes
## **Pack contents: Standard distribution board**
- 250A distribution bar
- RAL7035 textured finish
- Door closing latch
## **—**
## **MCB distribution board - Type B**
|**Description**|**Order codes**|
|---|---|
|Protecta Plus DB 4 Way 250A|EPP-W304|
|Protecta Plus DB 8 Way 250A|EPP-W308|
|Protecta Plus DB 12 Way 250A|EPP-W312|
|Protecta Plus DB 16 Way 250A|EPP-W316|
|Protecta Plus DB 20 Way 250A|EPP-W320|
|Protecta Plus DB 24 Way 250A|EPP-W324|
## **Pack contents: Horizontal split load kit**
- 2 x MID, Modbus ( RS485 ) & Pulse Meters
- Associated CTs
- Incoming isolators
- Internal cables
- **Requires 2 x MCB distribution board - Type B**
Please note as these kits allow for 4 to 24way boards cutting and crimping of cables is required.
## **— Horizontal split load kit**
|**Description**|**Order codes**|
|---|---|
|125A 3P Horizontal split load kit - 2 x Meters|EPP-HSL-1253P|
|125A 4P Horizontal split load kit - 2 x Meters|EPP-HSL-1254P|
|160A 3P Horizontal split load kit - 2 x Meters|EPP-HSL-1603P|
|160A 4P Horizontal split load kit - 2 x Meters|EPP-HSL-1604P|
|250A 3P Horizontal split load kit - 2 x Meters|EPP-HSL-2503P|
|250A 4P Horizontal split load kit - 2 x Meters|EPP-HSL-2504P|
PROTECTA PLUS – ORDER CODES
25
## **—**
## **Protecta Plus** Order Codes
## **Pack contents: Vertical Split Load Boards**
- 2/3 MID, Modbus ( RS485 ) & Pulse Meters
- Associated CTs
- Incoming terminals
- Internal cables
Please note, no additional assembly is required. Units will be delivered with meters pre-configured to internal C.T sizing.
## **—**
## **Vertical Split Load Boards - 42 variations are available**
|**Order codes**|**No. of outgoing**|**Incomer rating (A)**|**No. of poles**|
|---|---|---|---|
|EPP-VSL84<br>EPP-VSL88<br>EPP-VSL128|8+4 TPN<br>8+8 TPN<br>12+8 TPN|-125<br>-160<br>-250|3 P<br>4 P|
|EPP-VSL1212|12+12 TPN|||
|EPP-VSL168|16+8 TPN|||
|EPP-VSL844|8+4+4 TPN|||
|EPP-VSL1284|12+8+4 TPN|||
|**Example order codes**||||
|EPP-VSL1212-1253P 12+12 Way 125A 3P||||
|EPP-VSL168-2503P 16+8 Way 250A 3P||||
## **Vertical DB CT ratios**
Dual 125 125+100 Dual 160 160+125 Dual 250 250+160 Tri 125 125+100+100 Tri 160 160+125+100 Tri 250 250+160+125
Boards are supplied fully assembled and metering devices configured to C.T. ratio's
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
26
## **—**
## **Protecta Plus** Order Codes
## **Pack contents: Incoming kit**
- Copper connection kit and fittings
- Incoming device
- Cover plate
- Instruction leaflet
**—**
## **Incoming connection kit**
|**Description**|**Order codes**|
|---|---|
|125A 3P Switch incoming connection kit|EPP-1253P|
|125A 4P Switch incomingconnection kit|EPP-1254P|
|100A 4P RCD incoming connection kit 30mA Type AC - Left side neutral|EPP-1004R|
|160A 3P Switch incoming connection kit|EPP-1603P|
|160A 4P Switch incoming connection kit|EPP-1604P|
|250A 3P Switch incoming connection kit|EPP-2503P|
|250A 4P Switch incoming connection kit|EPP-2504P|
## **Pack contents: Incoming metering**
- 1 x Meter
- 1 x C.T Block
- 1 x Wiring Loom & DIN support
- Instruction leaflet
Please note as these kits allow for 4 to 24way boards cutting and crimping of cables is required.
**—**
## **Incoming metering**
|**Description**|**Order codes**|
|---|---|
|125A MID Approved c/w pulse output|EPP-METMOD125A|
|125A MID Approved c/w pulse output & Modbus ( RS485 )|EPP-METMOD125B|
|125A MID Approved c/w pulse output, Modbus ( RS485 ) Imp / Exp|EPP-METMOD125C|
|160A MID Approved c/w pulse output|EPP-METMOD160A|
|160A MID Approved c/w pulse output & Modbus ( RS485 )|EPP-METMOD160B|
|160A MID Approved c/w pulse output, Modbus ( RS485 ) Imp / Exp|EPP-METMOD160C|
|250A MID Approved c/w pulse output|EPP-METMOD250A|
|250A MID Approved c/w pulse output & Modbus ( RS485 )|EPP-METMOD250B|
|250A MID Approved c/w pulse output, Modbus ( RS485 ) Imp / Exp|EPP-METMOD250C|
PROTECTA PLUS – ORDER CODES
27
## **—**
## **Protecta Plus** Order Codes
## **Pack contents: Surge protection**
- 1 x Surge unit
- 1 x MCB 3P
- 1 x Wiring Loom & DIN support
- Instruction leaflet
Please note as these kits allow for 4 to 24way boards cutting and crimping of cables is required.
**—**
## **Surge protection**
|**Description**|**Order codes**|
|---|---|
|Type 2 surge protection - including 63A 3P MCB|EPP-SOULE|
|Type 2/3 surge protection - including 63A 3P MCB|EPP-FURSE|
## **Pack contents: Contactor control**
- 3P contactor
- Control circuit & fuse protection
- Instruction leaflet
## **—**
## **Contactor Control**
|**Description**|**Order codes**|
|---|---|
|125A AC1 rated 3P Contactor|EPP-CON125|
|160A AC1 rated 3P Contactor|EPP-CON160|
|250A AC1 rated 3P Contactor|EPP-CON250|
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
28
## **—**
## **Protecta Plus**
## Order Codes
## **Pack contents: Top extension boxes**
- Fixings
- DIN rail / mounting plate
- RAL7035 textured finish
## **—**
## **Extension boxes**
||||**Dimensions (mm)**||
|---|---|---|---|---|
||**No. of**||||
|**Type**|**modules**|**Height**|**(W x D)**|**Order codes**|
|Hinged door with 1 DIN rail|16|200|450 x 130|EPP-R1016|
|Hinged door with 2 DIN rail|32|400|450 x 130|EPP-R2032|
|Plain extension box 200mm||200|450 x 130|EPP-EB20|
|Plain extension box 400mm||400|450 x 130|EPP-EB40|
## **Pack contents: Type A distribution**
- Supplied factory fitted with 100A switch disconnector
- RAL7035 textured finish
## **—**
## **MCB Distribution board - Type A**
|**Description**|**Order codes**|
|---|---|
|Protecta Plus DB 4way 100A|HSMS4C|
|Protecta Plus DB 7way 100A|HSMS7C|
|Protecta Plus DB 11way 100A|HSMS11C|
|Protecta Plus DB 16way 100A|HSMS16C|
|Protecta Plus DB 20way 100A|HSMS20C|
PROTECTA PLUS – ORDER CODES
29
## **—**
## **Protecta Plus** Order Codes
## **Pack contents: Row type boards**
- Fixings
- DIN rail / mounting plate
- RAL7035 textured finish
## **—**
## **Row type extension boxes**
**==> picture [514 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Dimension|
|No. of|Sided|
|No. of modules|rows|width|Height|Order codes|
|36|2|4way DB|590|EPP-R2036|
|54|3|8way DB|730|EPP-R3054|
|72|4|12way DB|870|EPP-R4072|
|90|5|16way DB|1050|EPP-R5090|
|108|6|20way DB|1220|EPP-R6108|
|126|7|24way DB|1360|EPP-R7126|
**----- End of picture text -----**<br>
## **—**
## **Additional N/PE for side extension boxes**
**==> picture [387 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Order codes|
|Protecta Plus - Row Type N-Bar 9|EPP-N-09|
|Protecta Plus - Row Type N-Bar 13|EPP-N-13|
|Protecta Plus - Row Type N-Bar 17|EPP-N-17|
|Protecta Plus - Row Type N-Bar 21|EPP-N-21|
|Protecta Plus - Row Type E-Bar 9|EPP-PE-09|
|Protecta Plus - Row Type E-Bar 13|EPP-PE-13|
|Protecta Plus - Row Type E-Bar 17|EPP-PE-17|
|Protecta Plus - Row Type E-Bar 21|EPP-PE-21|
**----- End of picture text -----**<br>
**—**
## **Terminal cover**
**==> picture [388 x 95] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Order codes|
|Protecta Plus - Top Shroud|EPP-TC|
|Protecta Plus Mains TS - 4 Way|EPP-MTCO4|
|Protecta Plus Mains TS - 8 Way|EPP-MTCO8|
|Protecta Plus Mains TS - 12 Way|EPP-MTC12|
|Protecta Plus Mains TS - 16 Way|EPP-MTC16|
|Protecta Plus Mains TS - 20 Way|EPP-MTC20|
|Protecta Plus Mains TS - 20 Way|EPP-MTC24|
**----- End of picture text -----**<br>
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
30
## **—**
## **Protecta Plus Order Codes**
## **— Labels for outgoing circuits**
**==> picture [387 x 81] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|No. of ways|Order codes|
|4|EPP KIT-LAB04W|
|8|EPP KIT-LAB08W|
|12|EPP KIT-LAB12W|
|16|EPP KIT-LAB16W|
|20|EPP KIT-LAB20W|
|24|EPP KIT-LAB24W|
**----- End of picture text -----**<br>
## **—**
## **Replacement doors**
**==> picture [512 x 158] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Order codes|
|Protecta Plus Trans Door - 4 ways / 2 rows|EPP-TD-04|
|Protecta Plus Trans Door - 8 ways / 3 rows|EPP-TD-08|
|Protecta Plus Trans Door - 12 ways / 4 rows|EPP-TD-12|
|Protecta Plus Trans Door - 16 ways / 4 rows|EPP-TD-16|
|Protecta Plus Trans Door - 20 ways / 5 rows|EPP-TD-20|
|Protecta Plus Trans Door - 24 ways / 6 rows|EPP-TD-24|
|Protecta Plus Solid Door - 4 ways / 2 rows|EPP-ST-04|
|Protecta Plus Solid Door - 8 ways / 3 rows|EPP-ST-08|
|Protecta Plus Solid Door - 12 ways / 4 rows|EPP-ST-12|
|Protecta Plus Solid Door - 16 ways / 4 rows|EPP-ST-16|
|Protecta Plus Solid Door - 20 ways / 5 rows|EPP-ST-20|
|Protecta Plus Solid Door - 24 ways / 6 rows|EPP-ST-24|
**----- End of picture text -----**<br>
## **—**
## **Accessories**
**==> picture [389 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||
|---|---|
|Description|Order codes|
|MCB Blank RAL7035 Grey|EPP-BP1|
|MCB Blank RAL9004 Black|EPP-BP1B|
|Lock And Key|EPP-LK KEY|
|Side By Side Connection Kit|EPP-KIT JOIN|
|Padlock Adaptor|SA 1|
|Padlock C/W 2 X Keys|SA 2|
|125A Single Phase Kit|EPP-KIT-1251P*|
|250A Single Phase Kit|EPP-KIT-2501P**|
|Trunking adaptor plate|EPP-TRADT|
|Protecta Plus - Glandplate Plain|EPP-GP-B|
|Protecta Plus - Glandplate K Os|EPP-GP KO|
|19 Modules 30 mm Busbar|PS1/19/30|
**----- End of picture text -----**<br>
*** Requires kit EPP-1254P ** Required kit EPP-2504P**
31
MBCS – ORDER CODES
**—** bi —_ ern . PROTECTA PLUS 1 ABB has developed a new and personalised series of MCB distribution boards which can be expanded over time.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
32
## **—**
## **MCB - S 200 M series** Order codes
## **— S 200 series M B**
|**Rated**|**Rated current in kA**|**Order codes**|
|---|---|---|
|**current**|**IEC/EN 60898-1**||
|**in A**|**IEC/EN 60947-2**|**1 Pole**<br>**3 Pole**|
|6|10kA/15kA|S201M-B6<br>S203M-B6|
|10|10kA/15kA|S201M-B10<br>S203M-B10|
|13|10kA/15kA|S201M-B13<br>S203M-B13|
|16<br>20<br>25<br>32|10kA/15kA<br>10kA/15kA<br>10kA/15kA<br>10kA/15kA|S201M-B16<br>S203M-B16<br>S201M-B20<br>S203M-B20<br>S201M-B25<br>S203M-B25<br>S201M-B32<br>S203M-B32|
|40|10kA/15kA|S201M-B40<br>S203M-B40|
|50|10kA/15kA|S201M-B50<br>S203M-B50|
|63|10kA/15kA|S201M-B63<br>S202M-B63|
|80A|6kA|S201-B80<br>S203-B80|
|100A|6kA|S201-B100<br>S203-B100|
**—**
**S 200 series M C**
|**Rated**|**Rated current in kA**|**Order codes**|
|---|---|---|
|**current**|**IEC/EN 60898-1**||
|**in A**|**IEC/EN 60947-2**|**1 Pole**<br>**3 Pole**|
|6|10kA/15kA|S201M-C6<br>S203M-C6|
|10|10kA/15kA|S201M-C10<br>S203M-C10|
|13|10kA/15kA|S201M-C13<br>S203M-C13|
|16<br>20|10kA/15kA<br>10kA/15kA|S201M-C16<br>S203M-C16<br>S201M-C20<br>S203M-C20|
|25<br>32|10kA/15kA<br>10kA/15kA|S201M-C25<br>S203M-C25<br>S201M-C32<br>S203M-C32|
|40|10kA/15kA|S201M-C40<br>S203M-C40|
|50|10kA/15kA|S201M-C50<br>S203M-C50|
|63|10kA/15kA|S201M-C63<br>S202M-C63|
|80A|6kA|S201-C80<br>S203-C80|
|100A|6kA|S201-C100<br>S203-C100|
**—**
## **S 200 series M D**
|**Rated**|**Rated current in kA**|**Order codes**|
|---|---|---|
|**current**|**IEC/EN 60898-1**||
|**in A**|**IEC/EN 60947-2**|**1 Pole**<br>**3 Pole**|
|6|10kA/15kA|S201M-D6<br>S203M-D6|
|10<br>13|10kA/15kA<br>10kA/15kA|S201M-D10<br>S203M-D10<br>S201M-D13<br>S203M-D13|
|16<br>20<br>25<br>32|10kA/15kA<br>10kA/15kA<br>10kA/15kA<br>10kA/15kA|S201M-D16<br>S203M-D16<br>S201M-D20<br>S203M-D20<br>S201M-D25<br>S203M-D25<br>S201M-D32<br>S203M-D32|
|40|10kA/15kA|S201M-D40<br>S203M-D40|
|50|10kA/15kA|S201M-D50<br>S203M-D50|
|63|10kA/15kA|S201M-D63<br>S202M-D63|
**Please see glossary for complete MCB offering.**
MCB - S 200 SERIES - ORDER CODES
33
## **—**
## **MCB - S 200 P series** Order codes
## **—**
## **S 200 series P B**
|**Rated**|**Rated current in kA**|**Order codes**|
|---|---|---|
|**current**|||
|**in A**|**IEC/EN 60898-1**|**1 Pole**<br>**3 Pole**|
|6|25kA|S201P-B6<br>S203P-B6|
|10|25kA|S201P-B10<br>S203P-B10|
|13|25kA|S201P-B13<br>S203P-B13|
|16<br>20<br>25<br>32|25kA<br>25kA<br>25kA<br>15kA|S201P-B16<br>S203P-B16<br>S201P-B20<br>S203P-B20<br>S201P-B25<br>S203P-B25<br>S201P-B32<br>S203P-B32|
|40|15kA|S201P-B40<br>S203P-B40|
|50|15kA|S201P-B50<br>S203P-B50|
|63|15kA|S201P-B63<br>S203P-B63|
## **—**
## **S 200 series P C**
|**Rated**|**Rated current in kA**|**Order codes**|
|---|---|---|
|**current**|||
|**in A**|**IEC/EN 60898-1**|**1 Pole**<br>**3 Pole**|
|6|25kA|S201P-C6<br>S203P-C6|
|10|25kA|S201P-C10<br>S203P-C10|
|13|25kA|S201P-C13<br>S203P-C13|
|16<br>20|25kA<br>25kA|S201P-C16<br>S203P-C16<br>S201P-C20<br>S203P-C20|
|25<br>32|25kA<br>15kA|S201P-C25<br>S203P-C25<br>S201P-C32<br>S203P-C32|
|40|15kA|S201P-C40<br>S203P-C40|
|50|15kA|S201P-C50<br>S203P-C50|
|63|15kA|S201P-C63<br>S203P-C63|
## **—**
## **S 200 series P D**
|**Rated**|**Rated current in kA**|**Order codes**|
|---|---|---|
|**current**|||
|**in A**|**IEC/EN 60898-1**|**1 Pole**<br>**3 Pole**|
|6|25kA|S201P-D6<br>S203P-D6|
|10|25kA|S201P-D10<br>S203P-D10|
|13|25kA|S201P-D13<br>S203P-D13|
|16<br>20<br>25|25kA<br>25kA<br>25kA|S201P-D16<br>S203P-D16<br>S201P-D20<br>S203P-D20<br>S201P-D25<br>S203P-D25|
|32|15kA|S201P-D32<br>S203P-D32|
|40|15kA|S201P-D40<br>S203P-D40|
|50|15kA|S201P-D50<br>S203P-D50|
|63|15kA|S201P-D63<br>S203P-D63|
**Please see glossary for complete MCB offering.**
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
34
## **—**
## **RCBO DSE201 M - Type A**
## Order codes
## **—**
## **DSE201 M - Type A**
|**Rated**|**Rated**|**Rated current in kA**|**Order codes**|
|---|---|---|---|
|**residual**|**current**|||
|**current IΔn [mA]**|**in A**||**B Characteristic**<br>**C Characteristic**|
|10|6|10kA/15kA|DSE201 M B6 A10<br>DSE201 M C6 A10|
||10|10kA/15kA|DSE201 M B10 A10<br>DSE201 M C10 A10|
||16|10kA/15kA|DSE201 M B16 A10<br>DSE201 M C16 A10|
||20|10kA/15kA|DSE201 M B20 A10<br>DSE201 M C20 A10|
||25|10kA/15kA|DSE201 M B25 A10<br>DSE201 M C25 A10|
||32<br>40<br>50|10kA/15kA<br>10kA/15kA<br>10kA|DSE201 M B32 A10<br>DSE201 M C32 A10<br>DSE201 M B40 A10<br>DSE201 M C40 A10<br>DSE201 M B50 A10<br>DSE201 M C50 A10|
|30|6|10kA/15kA|DSE201 M B6 A30<br>DSE201 M C6 A30|
||10<br>16|10kA/15kA<br>10kA/15kA|DSE201 M B10 A30<br>DSE201 M C10 A30<br>DSE201 M B16 A30<br>DSE201 M C16 A30|
||20|10kA/15kA|DSE201 M B20 A30<br>DSE201 M C20 A30|
||25|10kA/15kA|DSE201 M B25 A30<br>DSE201 M C25 A30|
||32|10kA/15kA|DSE201 M B32 A30<br>DSE201 M C32 A30|
||40|10kA/15kA|DSE201 M B40 A30<br>DSE201 M C40 A30|
||50|10kA|DSE201 M B50 A30<br>DSE201 M C50 A30|
|100|6|10kA/15kA|DSE201 M C6 A100|
||10|10kA/15kA|DSE201 M C10 A100|
||16|10kA/15kA|DSE201 M C16 A100|
||20|10kA/15kA|DSE201 M C20 A100|
||25|10kA/15kA|DSE201 M C25 A100|
||32|10kA/15kA|DSE201 M C32 A100|
||40|10kA/15kA|DSE201 M C40 A100|
||50|10kA|DSE201 M C50 A100|
|300|6|10kA/15kA|DSE201 M C6 A300|
||10|10kA/15kA|DSE201 M C10 A300|
||16|10kA/15kA|DSE201 M C16 A300|
||20|10kA/15kA|DSE201 M C20 A300|
||25|10kA/15kA|DSE201 M C25 A300|
||32|10kA/15kA|DSE201 M C32 A300|
||40|10kA/15kA|DSE201 M C40 A300|
||50|10kA|DSE201 M C50 A300|
35
RCBO DSE201 M - T YPE AC – ORDER CODES
## **—**
## **RCBO DSE201 M - Type AC**
## Order codes
## **—**
## **DSE201 M - Type AC**
|**Rated**|**Rated**|**Rated current in kA**|**Order codes**|
|---|---|---|---|
|**residual**|**current**|||
|**current IΔn [mA]**|**in A**||**B Characteristic**<br>**C Characteristic**|
|10|6|10kA/15kA|DSE201 M B6 AC10<br>DSE201 M C6 AC10|
||10<br>16<br>20<br>25<br>32|10kA/15kA<br>10kA/15kA<br>10kA/15kA<br>10kA/15kA<br>10kA/15kA|DSE201 M B10 AC10<br>DSE201 M C10 AC10<br>DSE201 M B16 AC10<br>DSE201 M C16 AC10<br>DSE201 M B20 AC10<br>DSE201 M C20 AC10<br>DSE201 M B25 AC10<br>DSE201 M C25 AC10<br>DSE201 M B32 AC10<br>DSE201 M C32 AC10|
|30|40<br>50<br>6<br>10<br>16|10kA/15kA<br>10kA<br>10kA/15kA<br>10kA/15kA<br>10kA/15kA|DSE201 M B40 AC10<br>DSE201 M C40 AC10<br>DSE201 M B50 AC10<br>DSE201 M C50 AC10<br>DSE201 M B6 AC30<br>DSE201 M C6 AC30<br>DSE201 M B10 AC30<br>DSE201 M C10 AC30<br>DSE201 M B16 AC30<br>DSE201 M C16 AC30|
||20|10kA/15kA|DSE201 M B20 AC30<br>DSE201 M C20 AC30|
||25|10kA/15kA|DSE201 M B25 AC30<br>DSE201 M C25 AC30|
||32|10kA/15kA|DSE201 M B32 AC30<br>DSE201 M C32 AC30|
||40|10kA/15kA|DSE201 M B40 AC30<br>DSE201 M C40 AC30|
||50|10kA|DSE201 M B50 AC30<br>DSE201 M C50 AC30|
|100|6|10kA/15kA|DSE201 M C6 AC100|
||10|10kA/15kA|DSE201 M C10 AC100|
||16|10kA/15kA|DSE201 M C16 AC100|
||20|10kA/15kA|DSE201 M C20 AC100|
||25|10kA/15kA|DSE201 M C25 AC100|
||32|10kA/15kA|DSE201 M C32 AC100|
||40|10kA/15kA|DSE201 M C40 AC100|
||50|10kA|DSE201 M C50 AC100|
|300|6|10kA/15kA|DSE201 M C6 AC300|
||10|10kA/15kA|DSE201 M C10 AC300|
||16|10kA/15kA|DSE201 M C16 AC300|
||20|10kA/15kA|DSE201 M C20 AC300|
||25|10kA/15kA|DSE201 M C25 AC300|
||32|10kA/15kA|DSE201 M C32 AC300|
||40|10kA/15kA|DSE201 M C40 AC300|
||50|10kA|DSE201 M C50 AC300|
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
36
## **—**
## **RCCB F 200 series AC type**
## Order Codes
## **—**
**F 200 AC type - F202**
||**Rated**|**Rated**||
|---|---|---|---|
|**Number**|**residual**|**current**||
|**of poles**|**current IΔn [mA]**|**in A**|**Order codes**|
|2|10|16|F202 AC-16/0.01|
||30|25<br>25|F202 AC-25/0.01<br>F202 AC-25/0.03|
|||40<br>63|F202 AC-40/0.03<br>F202 AC-63/0.03|
||100|80<br>100<br>25|F202 AC-80/0.03<br>F202 AC-100/0.03<br>F202 AC-25/0.1<br>~~_—~~|
|||40|F202 AC-40/0.1|
|||63|F202 AC-63/0.1|
|||80|F202 AC-80/0.1|
|||100|F202 AC-100/0.1|
||300|25|F202 AC-25/0.3|
|||40|F202 AC-40/0.3|
|||63|F202 AC-63/0.3|
|||80|F202 AC-80/0.3|
|||100|F202 AC-100/0.3|
||500|25|F202 AC-25/0.5|
|||40|F202 AC-40/0.5|
|||63|F202 AC-63/0.5|
|||80|F202 AC-80/0.5|
|||100|F202 AC-100/0.5|
RCCB F 200 SERIES – ORDER CODES
37
## **—**
## **RCCB F 200 series AC type**
## Order Codes
## **—**
## **F 200 AC type - F204**
||**Rated**|**Rated**||
|---|---|---|---|
|**Number**|**residual**|**current**||
|**of poles**|**current IΔn [mA]**|**in A**|**Order codes**|
|4|30|25|F204 AC-25/0.03|
|||40<br>63|F204 AC-40/0.03<br>F204 AC-63/0.03|
||100|80<br>100<br>25|F204 AC-80/0.03<br>F204 AC-100/0.03<br>F204 AC-25/0.1|
|||40|F204 AC-40/0.1|
|||63|F204 AC-63/0.1|
|||80<br>100|F204 AC-80/0.1<br>F204 AC-100/0.1|
||300|25|F204 AC-25/0.3|
|||40|F204 AC-40/0.3|
|||63|F204 AC-63/0.3|
|||80|F204 AC-80/0.3|
|||100|F204 AC-100/0.3|
||500|25|F204 AC-25/0.5|
|||40|F204 AC-40/0.5|
|||63|F204 AC-63/0.5|
|||80|F204 AC-80/0.5|
|||100|F204 AC-100/0.5|
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
38
## **—**
## **Metering EQ series**
## Order codes
## **—**
**A series - A41**
|**80A SPN 4mod**|**80A SPN 4mod**|**Description**|**Order codes**|
|---|---|---|---|
|||Pulse output|A41 111 - 100|
|||Pulse output, RS-485|A41 112 - 100|
|||Pulse output, M-Bus|A41 113 - 100|
|||2 output, 2 input, RS-485|A41 312 - 100|
|||2 output, 2 input. M-Bus|A41 313 - 100|
**—**
**A series - A43**
|**80A TPN 7mod**|**80A TPN 7mod**|**Description**|**Order codes**|
|---|---|---|---|
|||Pulse output|A43 111 - 100|
|||Pulse output, RS-485|A43 112 - 100|
|||Pulse output, M-Bus|A43 113 - 100|
|||2 output, 2 input, RS-485|A43 312 - 100|
|||2 output, 2 input, M-Bus|A43 313 - 100|
## **—**
## **B series - B21**
|**65A SPN 2mod**|**65A SPN 2mod**|**Description**|**Order codes**|
|---|---|---|---|
|||Pulse output|B21 111 - 100|
|||Pulse output, RS-485|B21 112 - 100|
|||Pulse output, M-Bus|B21 113 - 100|
|||2 output, 2 input, RS-485|B21 312 - 100|
|||2 output, 2 input, M-Bus|B21 313 - 100|
**—**
## **B series - B23**
|**65A TPN 4mod**|**65A TPN 4mod**|**Description**|**Order codes**|
|---|---|---|---|
|||Pulse output|B23 111 - 100|
|||Pulse output, RS-485|B23 112 - 100|
|||Pulse output, M-Bus|B23 113 - 100|
|||2 output, 2 input, RS-485|B23 312 - 100|
|||2 output, 2 input, M-Bus|B23 313 - 100|
CIRCUIT MONITORING ST YSTEM - CMS - ORDER CODES
39
## **—**
## **Circuit Monitoring System - CMS**
Order Codes
ABB's circuit monitoring system (CMS) is a unique ultra-compact and high-performance multi-channel measurement system for branch monitoring. The system consists of a control unit and sensors with different measurement ranges and mounting possibilities.
## **—**
**Open core sensors** Open-core sensors 18 mm for Pro M & SMISSLINE installation devices with twin terminals
|**Description**|**0rder codes**|
|---|---|
|80 A|CMS-120PS|
|40 A|CMS-121PS|
|20 A|CMS-122PS|
## **—**
**Open core sensors** Open-core sensors 18 mm for DIN rail mounting (universally usable)
|**Description**|**0rder codes**|
|---|---|
|80 A|CMS-120DR|
|40 A|CMS-121DR|
|20 A|CMS-122DR|
## **—**
## **Control Units**
|**Description**|**0rder codes**|
|---|---|
|Control Unit CMS-600|CMS-600|
|Control Unit CMS-700|CMS-700|
**For more detailed information see p66.**
## **—**
## **Accessories**
|**Description**|**0rder Codes**|
|---|---|
|Cable 5m|CMS-802|
|Sensor connectors ( 35pcs )|CMS-820|
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
40
## **—**
## **ESB installation contactors**
## Order Codes
These devices are specifically made for commanding loads and signalling electrical conditions in any low-voltage distribution board. The functions of these devices are particularly switching, pushing and signalling electrical conditions in any installations (low-voltage area)
## **—**
## **ESB 24**
**==> picture [512 x 324] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||
|---|---|---|---|---|---|---|---|---|
|Control coil voltage|
|Numbe|r|
|Main|of|
|poles|modules|40-50 Hz|DC|Order codes|
|2 N.O.|A1|1|3|2|24 V|24 V|ESB 24-20*|
|230...240 V|230...240 V|ESB 24-20*|
|a|A2|2|4|
|4 N.O.|2|12 V|12 V|ESB 24-40*|
|A1|1|3|5|7|24 V|24 V|ESB 24-40*|
|110...120 V|110...120 V|ESB 24-40*|
|oy|A2|2|4|6|8|
|230...240 V|230...240 V|ESB 24-40*|
|4 N.C.|2|12 V|12 V|ESB 24-04*|
|A1|R1|R3|R5|R7|24 V|24 V|ESB 24-04*|
|110...120 V|110...120 V|ESB 24-04*|
|OTT|A2|R2|R4|R6|R8|
|230...240 V|230...240 V|ESB 24-04*|
|2 N.O. 2 N.C.|2|12 V|12 V|ESB 24-22*|
|A1|1|R3|R5|7|24 V|24 V|ESB 24-22*|
|110...120 V|110...120 V|ESB 24-22*|
|SaAa|A2|2|R4|R6|8|230...240 V|230...240 V|ESB 24-22*|
|2|12 V|12 V|ESB 24-31*|
|3 N.O. 1 N.C.|24 V|24 V|ESB 24-31*|
|A1|1|R3|5|7|110...120 V|110...120 V|ESB 24-31*|
|230...240 V|230...240 V|ESB 24-31*|
|aaAn|A2|2|R4|6|8|
|2|12 V|12 V|ESB 24-13*|
|4 N.O. 3 N.C.|24 V|24 V|ESB 24-13*|
|A1|R1|3|R5|R7|110...120 V|110...120 V|ESB 24-13*|
|230...240 V|230...240 V|ESB 24-13*|
|S|A2|amal|R2|4|R6|R8|
**----- End of picture text -----**<br>
*** Ensure voltage is selected**
ESB INSTALL ATION CONTACTORS – ORDER CODES
41
## **—**
## **ESB installation contactors**
## Order Codes
## **—**
## **ESB 40**
**==> picture [512 x 261] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control coil voltage<br>Main Number<br>poles of modules 40-50 Hz DC Order codes<br>4 N.O. 3 12 V 12 V ESB 40-40*<br>A1 1 3 5 7 24 V 24 V ESB 40-40*<br>110...120 V 110...120 V ESB 40-40*<br>A2 2 4 6 8 230...240 V 230...240 V ESB 40-40*<br>2 N.C. 3 24 V 24 V ESB 40-22*<br>A1 1 R3 R5 7 230 V 230 V ESB 40-22*<br>A2 2 R4 R6 8<br>1 N.C. 3 24 V 24 V ESB 40-31*<br>A1 1 R3 5 7 230 V 230 V ESB 40-31*<br>A2 2 R4 6 8<br>3 N.O. 3 24 V 24 V ESB 40-30*<br>A1 1 3 5 230 V 230 V ESB 40-30*<br>A2 2 4 6<br>2 N.O. 3 24 V 24 V ESB 40-20*<br>A1 1 3 230 V 230 V ESB 40-20*<br>A2 2 4<br>**----- End of picture text -----**<br>
*** Ensure voltage is selected**
**—**
## **ESB 63**
**==> picture [512 x 270] intentionally omitted <==**
**----- Start of picture text -----**<br>
Control coil voltage<br>Main Number<br>poles of modules 40-50 Hz DC Order codes<br>4 N.O. 3 12 V 12 V ESB 63-40*<br>A1 1 3 5 7 24 V 24 V ESB 63-40*<br>110...120 V 110...120 V ESB 63-40*<br>A2 2 4 6 8 230...240 V 230...240 V ESB 63-40*<br>1 N.C. 3 110 V 110 V ESB 63-31*<br>A1 1 R3 5 7 230 V 230 V ESB 63-31*<br>A2 2 R4 6 8<br>3 N.O. 3 230 V 230 V ESB 63-30*<br>A1 1 3 5 400 V 400 V ESB 63-30*<br>A2 2 4 6<br>2 N.O. 3 24 V 24 V ESB 63-20*<br>A1 1 3 230 V 230 V ESB 63-20*<br>A2 2 4<br>1 N.O. 1 N.C. 3 230 V 230 V ESB 63-11*<br>A1 1 R3<br>A2 2 R4<br>**----- End of picture text -----**<br>
- **Ensure voltage is selected**
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
42
## **—**
## **D Line digital time switches** Order Codes
## **D Line weekly digital time switches**
The unique design, with white backlit LCD display, and extreme ease of use with two lines of text menu and only four buttons, make D Line ideal to automate the installation functions.
Thanks to the innovative management of time vacation, the D Line digital time switches allow the exclusion of the normal weekly program in one or more periods of several years or between two different years.
The “Plus” version can transfer different types of program by using a D KEY to be quickly copied in using no digital time switches, avoiding the errors due to future modification. The “SYNCHRO” version can be coupled to the D DCF77 antenna, that allows an automatic synchronization of the digital time switch with the Frankfurt DCF77 time signal, or can be coupled to the D GPS antenna to allows synchronization received from the Global Positioning System.
The range includes 1 and 2 channel versions, equipped with large capacity internal battery to maintain operation without power supply and permanent memory EEPROM, to avoid the risk of program loss and to maintain the date and time settings in the event of power failure, irrespective of its duration.
The D Line is particularly useful in environments and situations where user management is required with a time schedule flexible enough to predict or exclude activities according to time and day of week or month.
## **—**
## **D Line switches**
||||**Channels no.**||**Type**|**Order codes**|
|---|---|---|---|---|---|---|
|D1 D1 Plus|D1 D1 Plus|D1 D1 Plus|1||D1|2CSM258763R0621|
||||1||D1 PLUS|2CSM257583R0621|
||||1|D1 SYNCHRO|D1 SYNCHRO|2CSM257493R0621|
||||2||D2|2CSM256313R0621|
||||2||D2 PLUS|2CSM277583R0621|
||||2|D2 SYNCHRO|D2 SYNCHRO|2CSM277363R0621|
**—**
## **Accessories**
|**Versions**|**Type**|**Order codes**|
|---|---|---|
|Programming key|D KEY|2CSM277143R0621|
|Programming software|D SW|2CSM299973R0621|
|DCF77 antenna|D DCF77|2CSM299983R0621|
|GPS antenna|D GPS|2CSM299993R0621|
**Please see page 70 for explanation of types**
D/T LINE DIGITAL TIME SWITCHES – ORDER CODES
43
## **—**
## **T Line modular twilight switches** Order Codes
—
01 T1
—
02 T1 PLUS
—
03 LS-D
## **T Line modular twilight switches**
These twilight switches allow to switch ON and switch OFF lighting devices according to a scheduled level of the ambient light. They are used in combination with an external sensor to detect if the ambient light is higher or lower than the set level.
A switching delay prevents them from operating unnecessarily when the light intensity suddenly changes (e.g. lightning, moving vehicles, etc.). The T1 twilight switch in 1 channel is preset at 10 lux.
from factory and is equipped with 2 signalling LEDs that indicate the setpoint value and display the status of the contact . The operating instructions are printed on the side of the product. T1 PLUS switches feature a setpoint that can be adjusted for 4 different scale values (2:40, 20:200, 200:2000, 2000:15000).This makes them ideal for daytime applications where the lux values are very high. With a 10 lux preset factory setting, they are equipped with 2 signalling LEDs that indicate the setpoint value and display the status of the contact.
## **—**
## **T Line modular twilight switches**
|**Brightness range**||||
|---|---|---|---|
|**lux**||**Type**|**Order codes**|
|2:200||T1|2CSM295563R1341|
|2:15000|T1 PLUS|T1 PLUS|2CSM295793R1341|
## **Accessories for T Line modular twilight switches**
The external sensor is supplied in the same package of the switch, but it’s also available separately as spare part. The upper part of the external case (with screw locking), is made up of
thermoplastic materials and bears up against ultraviolet rays to guarantee a homogeneous diffusion of the daylight internally. LS-D is also equipped with a cable gland.
**— Accessories**
|**Brightness range**|||
|---|---|---|
|**lux**|**Type**|**Order codes**|
|External sensor|LS-D|2CSM295723R1341|
**==> picture [7 x 2] intentionally omitted <==**
**----- Start of picture text -----**<br>
—<br>**----- End of picture text -----**<br>
**==> picture [7 x 2] intentionally omitted <==**
**----- Start of picture text -----**<br>
—<br>**----- End of picture text -----**<br>
—
01
02
03
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
44
## **—**
## **Modular sockets**
## Order Codes
## **— British standard modular sockets**
**==> picture [511 x 32] intentionally omitted <==**
**----- Start of picture text -----**<br>
Colour Modules Order codes<br>M1363 Grey 3 M1363<br>Grey with light 3 M1363-L<br>**----- End of picture text -----**<br>
## **—**
## **E 90 fuse switch disconnectors**
Order Codes
E 90 series fuse switch disconnectors are designed for switching circuits under load, providing protection against short circuits and overloads. The case is made of self-extinguishing thermoplastic material resistant to high temperatures (all materials are UL listed) while the contact clips are in silver plated copper. E 90 fuse switch disconnectors can be sealed or
padlocked to ensure operator safety during maintenance. Versions with blown fuse indicator allow to check whether the fuse is still working correctly or not. For easy and quick installation E 90 range is totally compatible with connecting bars, terminals and caps of S 200 MCBs. Thanks to cURus approval, they can be installed in UL certified machines.
## **— E 90 fuse switch disconnectors for 10.3 x 38 mm fuses (AC-22B)**
||||**Rated**||
|---|---|---|---|---|
|||**Number**|**current**||
|||**of poles**|**In**|**Modules**<br>**Order codes**|
|E92||1|32|1<br>E 91/32|
|eel||1|32|1<br>E 91/32s|
||Lae|3|32|3<br>E 93/32|
|E94||3|32|3<br>E 93/32s|
|*<br>e|||||
||<br>bk<br>=i<br>“<br>&<br>«6<br>eo|||||
|E94|||||
**Fuses not included**
45
**—** CMS
The CMS system allows users to measure AC and DC currents for up to 64 individual lines. Data can be remotely monitored via desktop or mobile device app.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
46
## **—**
## **Protecta Plus**
## Technical specifications
## **—**
## **Technical features**
|**Description**|||
|---|---|---|
|Standards/requirements||IEC BS EN 61439-1&2, ed.2 (2011-08)|
|**Rated current**|||
|Maximum load||250A at ambient temperature +35°|
|Rated operational voltage (Ue)||415 V AC|
|Rated frequency||50/60 Hz|
|Rated insulation voltage (Ui)||690 V|
|Rated conditional short circuit current (Icc)||35 kA|
|Neutral size||2 Brass bar each size (7*10) mm|
|Earth size||2 Brass bars each size (7*10) mm|
|Degree of protection|With Door|IP 43|
||Pan Assembly|IP 20|
|Mechanical impact strength|Cabinet enclosures|IK 07|
|Housing and door material|||
|Material Type||Cold rolled sheet steel 1 mm|
|Color||RAL 7035|
|Coating Type (Powder or)||Electrostatic powder coating, textured finish|
|Door opening angle||180°|
|Position of knockouts||Top and bottom|
|Type of Door Closure||Latch (Optional Lock)|
|Incoming cable connections*||125A >50 mm|
|||160A >70 mm|
|||250A >95 mm|
***For requirements above stated figures seek advise from technical services**
PROTECTA PLUS – DIMENSIONS
47
## **—**
## **Protecta Plus** Dimensions
—
01 Type B Distribution boards
**—**
**Type B Distribution boards**
—
02 Extension boxes
||**Height**|**Width**|**Depth**|**M1**|**M2**|
|---|---|---|---|---|---|
||**mm**|**mm**|**mm**|**mm**|**mm**|
|EPP-W304|590|450|125|358|500|
|EPP-R2036|590|450|125|358|500|
|EPP-W308|730|450|125|358|640|
|EPP-R3054|730|450|125|358|640|
|EPP-W312|870|450|125|358|780|
|EPP-R4072|870|450|125|358|780|
|EPP-W316|1,050|450|125|358|960|
|EPP-R5090|1,050|450|125|358|960|
|EPP-W320|1,220|450|125|358|1,130|
|EPP-R6108|1,220|450|125|358|1,130|
|EPP-W324|1,360|450|125|358|1,270|
|EPP-R7126|1,360|450|125|358|1,270|
**— Extension boxes**
||**Height**|**Width**|**Depth**|**M1**|**M2**|
|---|---|---|---|---|---|
||**mm**|**mm**|**mm**|**mm**|**mm**|
|EPP-EB20|200|450|125|358|110|
|EPP-EB40|400|450|125|358|310|
|EPP-RW1016|200|450|125|358|110|
|EPP-RW2032|400|450|125|358|310|
|EPP-CON|500|450|125|358|410|
—
—
01
02
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
48
## **—**
## **Protecta Plus**
## Dimensions
—
01 Horizontal split-load boards
## **—**
## **01 / 02 Horizontal split-load boards**
—
02 Connection philosophy
— 03 Type A distribution board
|||**Height**|**Height**|||
|---|---|---|---|---|---|
|||**mm**|**mm**|**Width**|**Depth**|
|||**125/160A**|**250A**|**mm**|**mm**|
|EPP-HSL 2x4way|EPP-HSL 2x4way|990|1,190|900|125|
|EPP-HSL 2x8way|EPP-HSL 2x8way|1,130|1,330|900|125|
|EPP-HSL 2x12way|EPP-HSL 2x12way|1,270|1,470|900|125|
|EPP-HSL 2x16way|EPP-HSL 2x16way|1,450|1,650|900|125|
|EPP-HSL 2x20way|EPP-HSL 2x20way|1,620|1,820|900|125|
|EPP-HSL 2x24way|EPP-HSL 2x24way|1,760|1,960|900|125|
EPP-HSL kits are aligned from the base of the DB. SLP-HSL assemblies are aligned from the top od the DB. SLP-HSL are complete assemblies designed for projects.
**==> picture [424 x 166] intentionally omitted <==**
**----- Start of picture text -----**<br>
EPP-HSL<br>SLP-HSL SLP-HSL<br>125A 125A 160A<br>160A 250A<br>250A<br>Isolator Direct Connection kit Meter & C.T<br>el eee :<br>— —<br>01 02<br>**----- End of picture text -----**<br>
## **—**
## **03 Housemaster compact sheet steal consumer unit (surface mounted)**
|**Number**<br>**of modules**|**Number**<br>**of modules**|**A**<br>**mm**|||||
|---|---|---|---|---|---|---|
||||||||
||||**B**<br>~~**mm**~~||||
||||~~**mm**~~||||
|HSMS 04C|4way|152|155||||
|HSMS 07C|||||||
|HSMS 11C<br>11way|||||||
|HSMS 16C<br>16way|||||||
|HSMS 20C<br>20way|||||||
**==> picture [156 x 117] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>256 110<br>88<br>256 142<br>i<br>110<br>**----- End of picture text -----**<br>
**==> picture [9 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
—<br>03<br>**----- End of picture text -----**<br>
PROTECTA PLUS – DIMENSIONS
49
## **—**
## **Protecta Plus** Dimensions
—
01 Vertical split-load board
## **—**
## **Vertical split-load boards**
—
02 Metering layout
||**Height**|**Width**|**Depth**|**M1**|**M2**|
|---|---|---|---|---|---|
|**125/160/250A**|**mm**|**mm**|**mm**|**mm**|**mm**|
|EPP-VSL 8+4|1,090|450|125|358|1,000|
|EPP-VSL 8+8|1,270|450|125|358|1,180|
|EPP-VSL 12+8|1,440|450|125|358|1,350|
|EPP-VSL 12+12*|1,580|450|125|358|1,490|
|EPP-VSL 16+8*|1,580|450|125|358|1,490|
|EPP-VSL 8+4+4*|1,380|450|125|358|1,290|
|EPP-VSL 12+4+4*|1,690|450|125|358|1,600|
* Please ensure RCBO lead lengths are considered.
**==> picture [88 x 21] intentionally omitted <==**
**----- Start of picture text -----**<br>
125A Isolator<br>160A @<br>250A = Meter & C.T<br>**----- End of picture text -----**<br>
**==> picture [7 x 2] intentionally omitted <==**
**----- Start of picture text -----**<br>
—<br>**----- End of picture text -----**<br>
—
01
02
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
50
## **—**
## **MCBs technical details** Definitions according to standards for miniature circuit breakers
## **Rated insulation voltage (Ui) according IEC/EN 60664-1:**
Root mean square (R.M.S.) withstand voltage value assigned by the manufacturer to the equipment or to a part of it, characterizing the specified (long-term) withstand capability of its insulation.
## **Rated operational voltage (Un)**
The rated voltage of a circuit-breaker is the value of voltage, assigned by the manufacturer, to which its performance (particularly the shortcircuit performance) is referred.
The same circuit-breaker may be assigned a number of rated voltages and associated rated short-circuit capacities.
## —
The rated insulation voltage is not necessarily equal to the rated voltage of the equipment which is primarily related to functional performance.
The voltage which appears across the terminals of a pole of a circuit-breaker after the breaking of the current.
The value of the power frequency recovery voltage shall be equal to 110% of the rated voltage of the circuit-breaker under test.
## **IEC/EN 60947-2**
## **IEC/EN 60898-1**
Miniature Circuit Breakers according IEC/EN 60898-1 are intended for the protection against over-currents of wiring installations in buildings and similar applications; they are designed for use by uninstructed people and for not being maintained.
This part of IEC/EN 60898 applies for a.c. airbreak circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25,000 A. As far as possible, it is in line with the requirements contained in IEC/EN 60947-2.
## **Rated short-circuit capacity (Icn)**
The rated short-circuit capacity of a circuitbreaker is the value of the ultimate short-circuit breaking capacity assigned to that circuitbreaker by the manufacturer. The sequence of operations shall be: O – t – CO
## **Service short-circuit capacity (Ics)**
A circuit-breaker having a given rated shortcircuit capacity has a corresponding fixed service short-circuit capacity (Ics). This is therefore generally not indicated.
This part of the IEC/EN 60947 applies to circuitbreakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1,000 V AC or 1,500 V DC It applies whatever the rated currents, the method of construction or the proposed applications of the circuit-breakers may be. The circuit-breakers are designed for use by instructed people.
## **Rated ultimate short-circuit breaking capacity Icu**
The rated ultimate short-circuit breaking capacity of a circuit-breaker is the value of ultimate shortcircuit breaking capacity assigned to that circuitbreaker by the manufacturer for the corresponding rated operational voltage. It is expressed as the value of the prospective breaking current, in kA (r.m.s. value of the AC component in the case of AC).
The sequence of operations shall be: O – t – CO
## **Rated service short-circuit breaking capacity Ics**
The rated service short-circuit breaking capacity of a circuitbreaker is the value of service shortcircuit breaking capacity assigned to that circuitbreaker by the manufacturer for the corresponding rated operational voltage. It is expressed as a value of prospective breaking current, in kA, corresponding to one of the specified percentages of the rated ultimate
51
**==> picture [109 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
ARTICLE OR CHAPTER TITLE<br>**----- End of picture text -----**<br>
—
01 The rated insulation voltage is not necessarily equal to the rated voltage of the equipment which is primarily related to functional performance
shortcircuit breaking capacity and rounded up to the nearest whole number. It may be expressed as a percentage of Icu (for example Ics = 25% Icu).
## **The sequence of operations shall be: O – t – CO – t – CO**
The following symbols are used for defining the sequence of operatons:
O represents an opening operation. CO represents a closing operation followed by an automatic opening. t represents the time interval between two short-circuit operations.
## **Rated operational voltage (Ue)**
The rated operational voltage of an equipment is a value of voltage which, combined with a rated operational current, determines the application of the equipment and to which the relevant tests and the utilization categories are referred.
For single-pole equipment it is generally stated as the voltage across the pole. For multi pole equipment it is generally stated as the voltage between phases.
Equipment may be assigned a number of combinations of rated operational voltage and associated making and breaking capacities for different duties and utilization categories.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
52
## **— MCBs technical details** Definitions according to standards for miniature circuit breakers
**==> picture [523 x 646] intentionally omitted <==**
**----- Start of picture text -----**<br>
— — —<br>Characteristic B IEC-EN60898 Characteristic C IEC-EN60898 Characteristic D IEC-EN60898<br>120 casein 12060+9—-9 1206079-4<br>6049-4 ewe | MA [hewn] e s woe |<br>20 || yj tf tt Tt tt 20 yt ft ttt 1 01 yf ft PEP Ty ty tt<br>| jo<br>107 Q t 104 Qt 07h Q e<br>6 1] a OO OO {| a 9 l] a OO<br>20 6 g& 6<br>— | 1 ° A NCEE — m “| 1oO °ee NCEE al D —_—5 41 i g NEIKEE EE EE<br>[ *ao10 P PY\ E INEfi ENN “t ao | \N eeMQ-LE a2 aot eaol | A\ XH++# TaineNUE FH -+H<br>ee uot 10 ny 10;-—V\ NS<br>6 ee — Ho NK 8 6{—\ a<br>4}ot NEP AJX 8 iift aaTLEa 674{—NeANTAN nooi!i i1 a|_|eee gol¢g 6;4{/—}—) IN 1—N |q1 Nei! NN<br>Po is PNG EL PLN EE EE<br>o0 s. t61——o| | AC |aF--——r{of ft o0 a. t6eeee| | tt oSsdaces|ee+ | |—| 0.6oaf_|oe Po| [| [| | tSHootSeatq |_faco|<br>ef 0 . 1 P| PEEa a Ea e e| SEPE Eapse<br>ee a ee ee ee | 0 .1 DC 0.1 a Oe [|<br>0 . 06 = a L111 11 =| T— a LO<br>oc e ot| | I} {| | 0 o.0 6 ot}| | || (b ) | 0.060.04 Sane 7<br>ao r Ho\ Co Loo t NAN Y K EEE TEA001 N K \A<br>1 1 . 5 2 3 456 810 15 20 30 1 1 . 5 2 3 456 810 15 20 30 1 #15 2 3 456 810 15 20 30 4050<br>3,5 5 10 10 1520 30<br>4 7 7 15<br>—> Multiples of rated current —> Multiple of rated current ——>><br>— —<br>Characteristic K IEC-EN60947-2 Characteristic Z IE C-EN609 4 7-2<br>120<br>60-2940 Pt tt | Te EE 60-K¢att i | t i t tt tTi<br>Tripping curve Tripping curve<br>o(\1 0 EEEQe from cold state \10| GiEHQe from cold state<br>6 | HO 6 |<br>ap WN@\\ titi Te tt ap \ | et te ty<br>'<br>— 1 \ Ne — NOR 1 a i! ee<br>aol KEELE FE FE ao "1 Nae<br>» 52 0 1N Nini Nb ING<br>10+——\| | ‘Sinaa | 20107-—APX 1!1 |] PEEa<br>4 tN " a 4 [| \ ee |<br>oN ' TL eee<br>Woa EY ;L PN . EE<br>o st . —= o6 {|— a<br>og | | | tT Tt tt AGH Ss= |_| o st |_| AC a<br>no t |R S oo t | iin<br>PL foe o t ef<br>0 .B 06 eto I 0 . 06 a Htt++_++<br>oo t _| | |ttt || oo t |_| () a<br>0 . 01 \ 0 . 01 \<br>1 1 52 3 456 810 15 20 30 1 1 52 3 456 810 15 20 30<br>10 14 21 2 3 45<br>Multiples of rated current —_> Multiples of rated current —_><br>2CSC400400F0202 2CSC400400F0202 2CSC400401F0202<br>Minutes<br>Seconds Seconds<br>2CSC400400F0202 2CSC400400F0202<br>**----- End of picture text -----**<br>
53
**—** ABB
ABB continually develops smart solutions for controlling and monitoring the flow of electricity, as well as improving energy efficiency in buildings and critical power applications.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
54
## **—**
## **MCB**
## S 200 Series technical features
## **—**
## **Technical features**
|||**General data**|**Specifications**||**S 200 M**|**S 200P**|
|---|---|---|---|---|---|---|
||||Standards||IEC/EN 60898-1,|IEC/EN 60898-1,<br>IEC/EN 60898-1,|
||||||IEC/EN 60947-2|IEC/EN 60947-2|
|*ia<br>i<br>omy|i|||Poles|–|UL 1077, CSA 22.2<br>No. 235<br>–|UL 1077, CSA 22.2 No. 235<br>1P, 2P, 3P, 4P, 1P+N, 3P+N|
|a||.||Tripping characteristics|–|B, C, D, K, Z|B, C, D, K, Z|
||a!||Rated current In|A|0.5...63A|–|
|.|||Rated current f|Hz|50/60Hz|50/60Hz|
||||Rated insulation voltage Uiacc.|–|–<br>440V AC (phase to phase)|250 V AC (phase to ground),|
||||to IEC/EN 60664-1|||500 V AC (phase to phase)|
||||Overvoltage category|–|III|–|
||||Pollution degree|–|3|2|
|||Data acc. to|Rated operational voltage Un|V|1P: 230/400V AC; 1P+N:|1P: 230/400V AC; 1P+N:<br>1P: 230V AC, 220V DC|
|||IEC/EN 60898-1|||230V AC ;|2P: 400V AC, 440V DC|
|||(except S200M UC|||2... 4P: 400V AC; 3P+N: 400V|2... 4P: 400V AC; 3P+N: 400V<br>3...4P: 400V AC*|
|||data acc. to|||||
|||IEC/EN60898-2)|Max. power frequency recovery voltage (Umax)|V 1P: 253V AC; 1P+N: 253V AC;|V 1P: 253V AC; 1P+N: 253V AC;<br>2P: 440V AC; 3...4P: 440V|2P: 440V AC; 3...4P: 440V<br>1P: 230V AC, 220V DC<br>2P: 400V AC, 440V DC|
||||||AC; 3P+N: 440V AC|3...4P: 400V AC*|
||||Min. operating voltage|V|12V AC - 12V DC|–|
||||Rated short-circuit capacity Icn|kA|10kA|≤ 25A: 25kA|
|||||||> 25A: 15kA|
||||Energy limiting class (B, C up to 40 A)|–|–<br>3|3|
||||Rated impulse withstand voltage Uimp. (1.2/50μs)|kV|–|–|
||||Dielectric test voltage|kV|2kV (50/60Hz, 1 min.)|2kV (50/60Hz, 1 min.)|
||||Reference temperature for tripping characteristics|oC|B, C, D: 30°C|30°C|
||||Electrical endurance|ops.|In < 32A: 20,000 ops (AC),|–|
||||||In ≥ 32A: 10,000 ops. (AC);|In ≥ 32A: 10,000 ops. (AC);|
||||||1,000 ops. (DC);||
|||Data acc. to|Rated operational voltage Ue|V||1P: 230V AC;|
|||IEC/EN 60947-2||||1P+N: 230V AC;|
|||||||2...4P: 400V AC;|
|||||||3P+N: 400V AC|
||||Max. power frequency recovery voltage (Umax)|V||1P: 253V AC;|
|||||||1P+N: 253V AC;|
|||||||2P...4P: 440V AC;|
|||||||3P+N: 440V AC;|
|||||||1P: 72V DC;|
|||||||2P: 125V DC|
||||Min. operating voltage|V|12V AC - 12V DC|12 V AC - 12V DC|
||||Rated ultimate short-circuit breaking capacity Icu|kA|15kA|≤ 25A: 25kA|
|||||||≥ 32A: 15kA|
||||Rated service short-circuit breaking capacity Ics|kA|≤ 40A: 11.2kA|≤ 25A: 12.5kA|
||||||50, 63A: 7.5kA|≤ 32…40A: 11.2kA|
|||||||50, 63A: 7.5kA|
||||||4kV (test voltage 6.2kV at|4kV (test voltage 6.2kV at|
||||Rated impulse withstand voltage Uimp. (1.2/50μs)|kV|sea level, 5kV at 2,000m)|–|
||||Dielectric test voltage|kV|2kV (50/60Hz, 1 min.)|–|
||||Reference temperature for tripping characteristics|°C|B, C, D: 55°C; K, Z: 20°C|B, C: 55°C; K, Z: 20°C|
||||Electrical endurance|ops.|In < 32A: 20,000 ops (AC),|In < 32A: 20,000 ops (AC), In ≥|
||||||In ≥ 32A: 10,000 ops. (AC);|In ≥ 32A: 10,000 ops. (AC);<br>32A: 10,000 ops. (AC); 1,000|
||||||1,000 ops. (DC);|ops. (DC);|
||||||(1 cycle 2s - ON, 13s - OFF, In ≤|(1 cycle 2s - ON, 13s - OFF, In ≤<br>(1 cycle 2s - ON,|
||||||32A),|13s - OFF, In ≤ 32A),|
||||||(1 cyle 2s - ON, 28s - OFF, In >|(1 cyle 2s - ON, 28s - OFF, In ><br>(1 cyle 2s - ON,|
||||||32A)|28s - OFF, In ≥ 32A)|
**Note:** * Only acc. to IEC/EN 60898-1 r switching
MCB - TECHNIC AL FE ATURES
55
## **—**
## **MCB**
## S 200 80A-100A series technical features
**—**
## **Technical features**
|**General Data**|**S 200 80A-100A**|
|---|---|
|Standards|IEC/EN 60898-1, IEC/EN 60947-2|
|Poles|1P, 2P, 3P, 4P, 1P+N, 3P+N|
|Tripping characteristics|B, C|
|Rated current In|80 A, 100 A|
|Rated frequency f|50/60 Hz|
|Rated insulation voltage Ui acc. to IEC/EN 60664-1 (VDE 0110-1)|440 V AC|
|Overvoltage category|III|
|Pollution degree|2|
|**IEC/EN 60898-1 (VDE 0641-11)**||
|Rated operational voltage Un|1P: 230/400 V AC; 1P+N: 230 V AC; 2P, 3P, 4P, 3P+N: 400 V AC|
|Max. power frequency recovery voltage Umax|1P: 253/440 V AC; 1P+N: 253 V AC; 2P, 3P, 4P, 3P+N: 440 V AC|
|Min. operating voltage|12 V AC|
|Rated short-circuit capacity Icn|6 kA|
|Rated impulse withstand voltage Uimp(1.2/50µs)|4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m)|
|Dielectrical test voltage|2 kV (50/60 Hz, 1 min.)|
|Reference temperature for tripping characteristics|B, C: 30 °C|
|Electrical endurance|10,000 ops. (AC); one cycle 2 s - ON, 28 s - OFF|
|**IEC/EN 60947-2 (VDE 0660-101)**||
|Rated operational voltage Ue|1P, 1P+N: 230 V AC; 2P, 3P, 4P, 3P+N: 400 V AC|
|Max. power frequency recovery voltage Umax|1P, 1P+N: 253 V AC; 2P, 3P, 4P, 3P+N: 440 V AC|
|Min. operating voltage|12 V AC|
|Rated ultimate short-circuit breaking capacity Icu|6 kA|
|Rated service short-circuit breaking capacity Ics|6 kA|
|Rated impulse withstand voltage Uimp(1.2/50 µs)|4 kV (test voltage 6.2 kV at sea level, 5 kV at 2,000 m)|
|Dielectrical test voltage|2 kV (50/60 Hz, 1 min.)|
|Reference temperature for tripping characteristics|B, C: 55 °C|
|Electrical endurance|10,000 ops. (AC); one cycle 2 s - ON, 28 s - OFF|
|**Mechanical data**||
|Housing|Insulation group I, RAL 7035|
|Toggle|Insulation group II, black, sealable|
|Contact position indication|Real CPI (red ON/green OFF)|
|Protection degree acc. to DIN EN 60529|IP20(1), IP40 in enclosure with cover|
|Mechanical endurance|20,000 ops.|
|Shock resistance acc. to DIN EN 60068-2-27|25 g, 2 shocks, 13 ms|
|Vibration resistance acc. to DIN EN 60068-2-6|5 g, 20 cycles at 5…150…5 Hz at 0.8 In|
|Environmental conditions (Damp heat cyclic) acc. to DIN EN|28 cycles with 55 °C/90-96 % and 25 °C/95-100 %|
|60068-2-30||
|Ambient temperature|-25 ... +55 °C|
|Storage temperature|-40 ... +70 °C|
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
56
## **—**
## **MCB**
S200 80A-100A series technical features and tripping characteristics
## **—**
## **Installation features**
|**Installation**|S 200 80A-100A|
|---|---|
|Terminal|Failsafe bi-directional cache clamp|
|Cross-section of conductors (top/bottom)|solid, stranded: 50 mm2/ 50 mm2|
||flexible: 50 mm2/ 50 mm2|
|Cross-section of busbars (top/bottom)|16 mm2/ 16 mm2|
|Torque|3.0 Nm|
|Screwdriver|Nr. 2 Pozidriv|
|Mounting|On DIN rail 35 mm acc. to EN 60715 by fast clip|
|Mounting position|any|
|Supply|any|
|**Dimensions and weight**||
|Mounting dimensions acc. to DIN 43880|Mounting dimension 1|
|Pole dimensions (H x T x B) mm|88.8 x 69 x 17.5|
|Pole weight|approx. 126 g|
|**Combination with auxiliary elements**||
|Auxiliary contact|Yes|
|Signal/auxiliary contact|Yes|
|Shunt trip|Yes|
|Unervoltage release|Yes|
|Motor Operating Device|Yes|
## **—**
## **Tripping characteristics**
|**Data acc. to**|**Tripping**<br>**characteristics**<br>**Rated**<br>**current In**<br>**Thermal release**(¹)<br>**Electromagnetic release**(²)<br>**Currents:**<br>**conventional**<br>**non-tripping**<br>**current**<br>**I1**<br>**Conventional**<br>**tripping current**<br>**I2**<br>**Tripping time**<br>**Range of**<br>**instantaneous**<br>**tripping**<br>**Tripping**<br>**time**|**Thermal release**(¹)<br>**Electromagnetic release**(²)|
|---|---|---|
|DIN EN 60898-1<br>(VDE 0641-11)|B<br>**80 up to**<br>**100 A**<br>1.13 · In<br>1.45 · In<br>> 2 h<br>< 2 h<br>3 · In5 · In<br>0.1 ... 90 s<br>< 0.1 s||
||C<br>**80 up to**<br>**100 A**<br>1.13 · In<br>1.45 · In<br>> 2 h<br>< 2 h<br>5 · In10 · In<br>0.1 ... 30 s<br>< 0.1 s||
(¹) The thermal releases are calibrated to a nominal reference ambient temperature; for B and C the reference value is 30 °C.
In the case of higher ambient temperatures, the current values fall by approx. 6 % for each 10 K temperature rise.
(²) The indicated tripping values of electromagnetic tripping devices apply to a frequency of 50/60 Hz. The thermal release operates independent of frequency.
RCBO DSE201 M - TECHNIC AL FE ATURES
57
## **—**
## **RCBO DSE201 M**
## Technical features
## **—**
## **Technical features**
## **Electrical features**
|**Electrical features**|||
|---|---|---|
|Standards||IEC 61009-1;IEC 61009-2-2;AS/NZS 61009|
|Type(wave form of the earth leakage sensed)||AC,A|
|Number ofpoles||1P+N|
|Rated current In||A<br>6≤ In ≤ 50|
|Rated sensitivityIΔn||mA<br>10,30,100,300|
|Rated voltage Ue||V<br>230-240|
|Insulation voltage Ui||V<br>500 V AC|
|Overvoltage category||III|
|Pollution degree||2|
|Max. operatingvoltage||V<br>264|
|Min. operating voltage for protection against IΔn residual<br>sinusoidal alternatingcurrents||V<br>85|
|Min. operatingvoltage of circuit test||V<br>195|
|Rated frequency||Hz<br>50/60|
|Rated breakingcapacityacc. to IEC 61009|ultimate Icn|A<br>10000|
|Rated breakingcapacityacc. to IEC 60947-2|ultimate Icn|kA<br>15(for 6A≤ In ≤ 40A)|
|||kA<br>10(for In = 50A)|
||service Ics|kA<br>7.5|
|Rated residual breakingcapacityIΔm||kA<br>10|
|Rated impulse withstand voltage(1.2/50)Uimp||kV<br>4 kV(test voltage 6.2kV at sea level,5kV at 2000m)|
|Dielectric test voltage at ind. freq. for 1 min.||kV<br>2.5 kV(50 / 60Hz,1 min.)|
|Thermomagnetic release - characteristic|B: 3 In≤ Im≤ 5 In||
||C: 5 In≤ Im≤ 10 In||
|Surge current resistance(wave 8/20)||A<br>250|
|**Mechanical data**|||
|Housing||insulationgroupII,RAL 7035|
|Toggle||insulation group IIIA, black, sealable in ON-OFF<br>positions|
|Contactposition indication||CPI on toggle(I ON / 0 OFF)|
|Electrical life||operations<br>10000|
|Mechanical life||operations<br>20000|
|Protection degree|housing|IP4X|
||terminals|IP2X|
|Shock resistance acc. to IEC/EN 60068-2-27||30g- 2 shocks - 13ms|
|Vibration resistance acc. to IEC/EN 60068-2-6||0.35mm or 5g - 20 cycles at 5…150…5 Hz<br>without load|
|Environmental conditions (damp heat)<br>acc. to IEC/EN 60068-2-30||°C/RH<br>28 cycles with 55°C/90-96% and 25°C/95-100%|
|Reference temperature for settingof thermal element||°C<br>30|
|Ambient temperature(with dailyaverage ≤ +35 °C)||°C<br>-25…+55|
|Storage temperature||°C<br>-40…+70|
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
58
## **—**
## **RCBO DSE201 M**
## Technical features and dimentions
## **—**
## **Installation features**
|**Installation**||||
|---|---|---|---|
|Terminal type|top (load side)||failsafe cage (shock protected)|
||bottom (line side)||failsafe bi-directional cylinder-lift terminal (shock|
||||protected)|
|Terminal size for cables|load side (top)|mm²|16|
||line side (bottom)|mm²|25|
|Terminal size for busbars|load side (top)||only for wire connection|
||line side (bottom)|mm²|10 (Standard ABB busbar / distribution board system)|
|Tightening torque|top (load side)|Nm|1.2|
||bottom (line side)|Nm|2.8|
|Neutral load cable|Type||low smoke halogen free|
||Lenght|mm|750|
||Section|mm²|2.5 mm² up to 20 A; 4 mm² up to 50 A|
||Color||blue|
|Functional earth cable|Type||low smoke halogen free|
||Lenght|mm|750|
||Section|mm²|0.75|
||Color||white|
|Mounting|||on DIN rail EN 60715 (35 mm) by means of fast clip|
||||device in consumer unit Type A according to IEC|
||||61439-1&3, BS EN 61439-1&3, in distribution board|
||||Type B accordingto IEC 61439-1&3,BS EN 61439-1&3.|
|Supply from|||bottom terminal|
|**Dimensions and weight**||||
|Dimensions (H x D x W)||mm|100 x 68.9 x 17.6|
|Weight||g|180|
|**Combination with auxiliary elements**||||
|Auxiliary contact|yes|||
|Signal contact / auxiliary switch yes||||
|Shunt trip yes||||
|Undervoltage release yes||||
|Overvoltage release yes||||
|Auxiliary contact for MCBs bottom fitting yes||||
|Signal contact / auxiliary switch|yes|||
|Shunt trip|yes|||
|Undervoltage release|yes|||
|Overvoltage release|yes|||
|Auxiliary contact for MCBs bottom fitting<br>—|yes|||
|01 50A version is||||
|115 mm height||||
59
RCCB F 200 SERIES - TECHNIC AL FE ATURES
## **—**
## **RCCB F 200 series**
## Technical features
## **—**
## **Technical features**
|**Features**|**Specifications**||||**F 200AC**|
|---|---|---|---|---|---|
|Electrical features||||||
||Standards|||IEC/EN 61008-1; IEC/EN 61008-2-1, UL 1053 (¹)||
||Type (wave form of the earth leakage|||–|–<br>AC|
||Poles|||–|2P, 4P (for 125 A only 4P)|
||Rated current In|||A|16, 25, 40, 63, 80, 100, 125|
||||||0.01-0.03-0.1-0.3-0.5|
||Rated sensitivity IΔn<br>Rated voltage Ue|||A<br>V|50/60Hz<br>230/400 - 240/415|
|||||V|480Y/277 (up to 100 A|
||Insulation voltage Ui||–|V|500|
||Max. operating voltage of circuit test|||V|110 (185 for 125 A); 195 for F 200 left neutral|
||||||170 (150 for 125 A); 300 for F 200 left|
||||||neutral for IDn = 30 mA (⁵)|
|(¹) Ground-fault sensing and relaying<br>equipment-component (up to 63 A).||||V|277 (up to 100 A); 480 for F 200 left neutral (⁴|
|(²) Prior to connection of aluminium<br>conductors (≥ 4 mm²) ensure that their<br>contact points are cleaned, brushed<br>and coated with grease.|Min. operating voltage of circuit test|||V|110 (185 for 125 A); 195 for F 200 left neutral<br>170 (150 for 125 A); 300 for F 200 left<br>neutral for IDn = 30 mA (⁵)|
|(³) For S700-E/K 100A, S750-E 63A,<br>S750DR-E/K 63A and other SCPD|Rated frequency|||Hz|50…60|
|coordination values see Chapter 3 of|Rated conditional short-circuit current||||277 (up to 100 A); 480 for F 200 left|
|Solutions for electrical distribution in|Inc=IΔ (³)|||kA|neutral (⁴|
|buildings – technical details.<br>(⁴) F200 left neutral has not the UL|Rated residual breaking capacity IΔm=Im|||kA|1 (1.25 for 125 A)|
|certification and the UL mark.<br>) Only for versions with marking<br>according to EN 61008-1; EN 61008-2-1.|Rated impulse withstand voltage (1.2/50) Uimp<br>Dielectric test voltage at ind. freq. for 1 min.|||kV<br>kV|4<br>2.5|
||Overvoltage category|||–|III, disconnector abilities|
||Surge current resistance (wave 8/20)|||A|250|
|Mechanical features|Toggle|||–|Blue sealable in ON-OFF position|
||Contact position indicator (CPI)|||–|Yes|
||Electrical life||–|–|10000 (2000 for 125 A)|
||Mechanical life||–|–|20000 (5000 for 125 A)|
||Protection degree|Housing|||IP4X|
|||Terminals|||IP2X|
||Environmental conditions (damp heat) acc. to IEC/EN 60068-2-||||28 cycles with 55°C/90-96% and|
||30||°C/RH|°C/RH|°C/RH<br>25°C/95|
||Ambient temperature (with daily average ≤ +35 °C)|||°C|-25…+55 (-25...+40 for 125A)|
||Storage temperature||–|°C|-40…+70|
|Installation|Terminal type|Failsafe bi-directional cylinder-lift terminal at top and bottom||||
||||||(shock protected) (cage for In > 63A) (2)|
||Terminal size top/bottom for cable|||mm2|25/25 (35/35 single slot terminal for In > 63A)|
|||UL/CSA||AWG|18-4 (upto 63A)|
||Terminal size top/bottom for busbar|IEC||mm2|10/10 (not for In = 80-100A)|
|||UL/CSA||AWG|18-8 (upto 63A)|
||Tightening torque|||Nm|2.8 (3 for In = 125A)|
|||UL/CSA||in-lbs.|25 (up to 63A)|
||Tool|||–|Nr. 2 Pozidriv|
||||||On DIN rail EN 60715 (35mm) by means|
||Mounting|||–|of fast clip device|
||Connection|||–|From top and bottom|
||||||It is possible without using any tools only|
||Withdrawal from busbar|||–|from the bottom (not for 125A)|
|Dimensions|Dimensions (H x D x W)|||mm|85 x 69 x 35|
|and weight|Weight|||g|200|
|Combination<br>with auxiliary<br>elements|Combinable with:|Auxiliary contact<br>Signal contact/auxiliary switch||Signal contact/auxiliary switch|Yes (no for 125A)<br>Yes|
|||Shunt trip|||Yes (no for 125A)|
|||undervoltage release|undervoltage release||Yes (no for 125A)|
(¹) Ground-fault sensing and relaying equipment-component (up to 63 A).
(²) Prior to connection of aluminium conductors (≥ 4 mm²) ensure that their contact points are cleaned, brushed and coated with grease.
(³) For S700-E/K 100A, S750-E 63A, S750DR-E/K 63A and other SCPD coordination values see Chapter 3 of Solutions for electrical distribution in buildings – technical details.
(⁴) F200 left neutral has not the UL certification and the UL mark. ([5] ) Only for versions with marking according to EN 61008-1; EN 61008-2-1.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
60
## **—**
## **EQ Meter - A series** Technical features
## **—**
## **Technical features**
||**A41**||**A43**|
|---|---|---|---|
|**Voltage/current inputs**||||
|Nominal voltage|230 V AC|3x230/400 V AC||
|Voltage range|57.7 - 288 V AC(-20% - +15%)|3x57.7/100 ... 288/500 V AC(-20% - +15%)||
|Power dissipation voltage circuits|0.8 VA(0.8 W)total|||
|Power dissipation current circuits|0.007 VA(0.007 W)at 230 V AC and Ib|0.007 VA(0.007 W) perphase at 230 V AC and Ib||
|Base current Ib|5 A|5 A||
|Rated current In|-|-||
|Reference current Iref|5 A|5 A||
|Transitional current Itr|0.5 A|0.5 A||
|Maximum current Imax|80 A|80 A||
|Minimum current Imin|0.25 A|0.25 A||
|Startingcurrent Ist|< 20 mA|< 20 mA||
|Terminal wire area|1 - 25 mm2|1 - 25 mm2||
|Recommended tighteningtorque|3 Nm|3 Nm||
|**Communication**||||
|Terminal wire area|0.5 - 1 mm2|0.5 - 1 mm2||
|Recommended tighteningtorque|0.25 Nm|||
|Transformer ratios||||
|Configurable voltage ratio(VT)|-|-||
|Configurable current ratio(CT)|-|-||
|Pulse indicator(LED)||||
|Pulse frequency|1000 imp/kWh|1000 imp/kWh||
|Pulse length|40 ms|40 ms||
|General data||||
|Frequency|50 or 60 Hz ± 5%|||
|AccuracyClass|B(Cl.1)or Reactive Cl. 2|A(Cl.2),B(Cl.1)or Reactive Cl. 2||
|Active energy|1%|1%,2%||
|Displayof energy|Pixel oriented|||
|**Environmental**||||
|Operatingtemperature|-40°C - +70°C|||
|Storage temperature|-40°C - +85°C|||
|Humidity|75%yearlyaverage,95% on 30 days/year|||
|Resistance to fire and heat|Terminal 960°C,cover 650°C(IEC 60695-2-1)|||
|Resistance to water and dust|IP20 on terminal block without protective enclosure|and IP51 in protective enclosure, according to IEC||
||60529.|||
|Mechanical environment|Class M2 in accordance with the MeasuringInstrument||Directive(MID).(2004/22/EC).|
|Electromagnetic environment|Class E2 in accordance with the MeasuringInstrument Directive(MID), (2004/22/EC).|||
|**Outputs**||||
|Current|2 - 100 mA|||
|Voltage|5 - 240 V AC/DC. For meters with only1 output,5 - 40 V||DC.|
|Pulse output frequency|Programmable: 1 - 999999 imp/kWh|||
|Pulse length|Programmable: 10 - 990 ms|||
|Terminal wire area|0.5 - 1 mm2|||
|Recommended tighteningtorque|0.25 Nm|||
|**Inputs**||||
|Voltage|0 - 240 V AC/DC|||
|OFF|0 - 12 V AC/DC|||
|ON|57-240 V AC/24 - 240 V DC|||
|Min.pulse length|30 ms|||
|Terminal wire area|0.5 - 1 mm2|||
|Recommended tighteningtorque|0.25 Nm|||
|**EMC compatibility**||||
|Impulse voltage test|6 kV 1.2/50µs(IEC 60060-1)|||
|Surge voltage test|4 kV 1.2/50µs(IEC 61000-4-5)|||
|Fast transient burst test|4 kV(IEC 61000-4-4)|||
|Immunityto electromagnetic HF-fields|80 MHz - 2 GHz at 10 V/m(IEC 61000-4-3)|||
|Immunityto conducted disturbance|150 kHz - 80 MHz, (IEC 61000-4-6)|||
|Immunityto disturbance with harmonics|2kHz - 150kHz|||
|Radio frequencyemission|EN 55022,class B(CISPR22)|||
|Electrostatic discharge|15 kV(IEC 61000-4-2)|||
|Standards|IEC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-22 class 0,5 S, IEC 62053-23 class 2, IEC 62054-21, GB/T|||
||17215.211-2006, GB/T 17215.321-2008 class 1 & 2,|GB/T 17215.322-2008 class 0,5 S, GB 4208-2008, EN||
||50470-1, EN 50470-3 category A, B & C|||
|**Mechanical**||||
|Material|Polycarbonate in transparent front glass, bottom case, upper||case and terminal cover, Glass reinforced polycarbonate in|
||terminal block.|||
|**Dimensions**||||
|Width|70 mm|123 mm||
|Height|97 mm|97 mm||
|Depth|65 mm|65 mm||
|DIN modules|4|7||
*) Only A44 552 - 110 and A44 553 - 110
EQ METER - A/B SERIES - TECHNIC AL FE ATURES
61
## **—**
## **EQ Meter - B series** Technical features
## **—**
## **Technical features**
||**B21**|**B23**|**B24**|
|---|---|---|---|
|Voltage/current inputs||||
|Nominal voltage|230 V AC|3 x 230/400 V AC||
|Voltage range|220-240 V AC (-20%- +15%)|3 x 220-240 V AC (-20%- +15%)||
|Power dissipation voltage circuits|0.9 VA (0,4 W) total|1.6 VA (0.7 W) total||
|Power dissipation current circuits|0.014 VA (0.014 W) at 230 V AC and I~~b~~|0.007 VA (0.007 W) per phase at 230 V AC and I~~b~~||
|Base current Ib|5 A||-|
|Rated current In|-||1 A|
|Reference current Iref|5 A||-|
|Transitional current Itr|0.5 A||0.05 A|
|Maximum current Imax|65 A||6 A|
|Minimum current Imin|0.25 A||0.02 A|
|Starting current Ist|<20 mA||<1 mA|
|Terminal wire area|1-25 mm2||0.5-10 mm2|
|Recommended tightening torque|3 Nm||1.5 Nm|
|**Communication**||||
|Terminal wire area|0.5-1 mm2|||
|Recommended tightening torque|0.25 Nm|||
|**Transformer ratios**||||
|Configurable current ratio (CT)|-||1/9-9999/1|
|**Pulse indicator (LED)**||||
|Pulse frequency|1000 imp/kWh|1000 imp/kWh|5000 imp/kWh|
|Pulse length|40 ms|40 ms|40 ms|
|**General data**||||
|Frequency|50 or 60 Hz ± 5%|||
||||B (Cl. 1) or C (Cl. 0,5 S) and Reactive|
|Accuracy Class|B (Cl. 1) and Reactive Cl. 2|B (Cl. 1) and Reactive Cl. 2|Cl. 2|
|Active energy|1%|1%|0.5%, 1%|
|Display of energy|6 digit LCD|7 digit LCD||
|**Environmental**||||
|Operating temperature|-40°C- +70°C|||
|Storage temperature|-40°C- +85°C|||
|Humidity|75% yearly average, 95% on 30 days/year|||
|Resistance to fire and heat|Terminal 960°C, cover 650°C (IEC 60695-2-1)|||
|Resistance to water and dust|IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529.|||
|Mechanical environment|Class M2 in accordance with the Measuring Instrument Directive (MID), (2004/22/EC).|||
|Electromagnetic environment|Class E2 in accordance with the Measuring Instrument Directive (MID), (2004/22/EC).|||
|**Outputs**||||
|Current|2-100 mA|||
|Voltage|5-240 V AC/DC. For meters with only 1 output 5-40 V DC.|||
|Pulse output frequency|Programmable: 1-999999 imp/kWh|||
|Pulse length|Programmable: 10-990 ms|||
|Terminal wire area|0.5-1 mm2|||
|Recommended tightening torque|0.25 Nm|||
|**Inputs**||||
|Voltage|0-240 V AC/DC|||
|OFF|0-12 V AC/DC|||
|ON|57-240 V AC/24-240 V DC|||
|Min. pulse length|30 ms|||
|Terminal wire area|0.5-1 mm2|||
|Recommended tightening torque|0.25 Nm|||
|**EMC compatibility**||||
|Impulse voltage test|6 kV 1.2/50μs (IEC 60060-1)|||
|Surge voltage test|4 kV 1.2/50μs (IEC 61000-4-5)|||
|Fast transient burst test|4kV (IEC 61000-4-4)|||
|Immunity to electromagnetic||||
|HF-fields|80 MHz-2 GHz (IEC 61000-4-6)|||
|Immunity to conducted disturbance|150kHz-80MHz (IEC 61000-4-6)|||
|Immunity to disturbance with har-||||
|monics|2kHz-150kHz|||
|Radio frequency emission|EN 55022, class B (CISPR22)|||
|Electrostatic discharge|15 kV (IEC 61000-4-2)|||
||IEC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-22 class 0,5 S, IEC 62053-23 class 2, IEC 62054-21, GB/T 17215.211-2006, GB/T|||
|Standards|17215.312-2008 class 1 & 2, GB/T 17215.322-2008 class 0,5 S, GB 4208-2008, EN 50470-1, EN 50470-3 category A, B & C|||
|**Mechanical**||||
||Polycarbonate in transparent front glass. Glass reinforced polycarbonate in bottom case and upper case. Polycarbonate in|||
|Material|terminal cover.|||
|**Dimensions**||||
|Width|35 mm|70 mm||
|Height|97 mm|97 mm||
|Depth|65 mm|65 mm||
|DIN modules|2|4||
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
62
## **—**
## **EQ Meter - A series**
## Wiring diagram
**==> picture [280 x 67] intentionally omitted <==**
**----- Start of picture text -----**<br>
— —<br>01 Terminal block A41 Terminal block A41 (A)<br>—<br>02 Terminal block A43 1 3 4 6<br>—<br>03 Terminal block A44 L<br>N — ype<br>**----- End of picture text -----**<br>
**— Terminal block A43 (A)**
**==> picture [174 x 57] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 wire connection, 2 elements<br>1 3 4 6 7 9 10 12<br>L1<br>L2<br>L3<br>**----- End of picture text -----**<br>
**==> picture [232 x 157] intentionally omitted <==**
**----- Start of picture text -----**<br>
(C) (B)<br>(C) (B)<br>(A) (A)<br>—<br>SET<br>OK<br>**----- End of picture text -----**<br>
**==> picture [168 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 wire connection, 3 elements<br>1 3 4 6 7 9 10 12<br>L1<br>L2<br>L3<br>N<br>**----- End of picture text -----**<br>
**==> picture [58 x 136] intentionally omitted <==**
**----- Start of picture text -----**<br>
(C) (B)<br>(A)<br>**----- End of picture text -----**<br>
—
— 03
01
02
EQ METER - A/B SERIES - WIRING DIAGR AM
63
## **—**
## **EQ Meter - B series**
## Wiring diagram
**==> picture [500 x 635] intentionally omitted <==**
**----- Start of picture text -----**<br>
— —<br>01 Terminal block B21 Terminal block B21<br>—<br>02 Terminal block B23<br>| 1 3 L_| 5<br>—<br>03 Terminal block B24<br>L<br>N<br>—<br>Terminal block B23<br>3 wire connection, 2 elements 4 wire connection, 3 elements<br>vO 1 3 4 6 7 9 Z 11 yY oO 1 3 4 6 7 9 C1 11<br>L1 | L1<br>L2 = L2 —_ =<br>L3 L3<br>N<br>—<br>Terminal block B24<br>3 wire connection, 2 elements 4 wire connection, 3 elements<br>1 2 3 5 7 8 9 11 S1 S2 1 2 3 4 5 6 7 8 9 11 S1 S2<br>P1 P2 P1 P2<br>L1L2 P1 P1 = L1L2 P1 P1 P1 =<br>L3 SIR L3<br>N<br>= PRIS<br>1 Phase in 1 4 7 Phase in 1 4 7 Current in<br>Oo ooo ooo<br>3 Phase out 3 6 9 Phase out 2 5 8 Voltage<br>Oo Ooo ooo<br>5 Neutral 11 Neutral 3 6 9 Current out<br>Oo Oo Ooo<br>Oo 11 Neutral<br>Ooooooo 11 1 2 4 5 7 8<br>11 1 4 7<br>5 1<br>LJ L] oooag wetitsDMDYE<br>f{-4 Kanes<br>a<br>(|<br>f | —_<br>(A & B )<br>3 6 9<br>a i P “ Td O<br>**----- End of picture text -----**<br>
**==> picture [387 x 187] intentionally omitted <==**
**----- Start of picture text -----**<br>
11 1 4 7<br>5 1<br>LJ L] oooag<br>f{-4 Kanes<br>a<br>f<br>a (A & B ) 3 i (A & B ) P<br>3 6 9<br>|| Ooo<br>— — —<br>01 02 03<br>**----- End of picture text -----**<br>
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
64
## **—**
## **EQ Meter - A/B series**
## Inputs/ouputs and communication
**—**
## **Inputs / outputs (B)**
**==> picture [68 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 outputs, 2 inputs<br>**----- End of picture text -----**<br>
**==> picture [139 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Out1 Out2 Inp3 Inp4<br>13 15 16 17 18<br>**----- End of picture text -----**<br>
**==> picture [149 x 56] intentionally omitted <==**
**----- Start of picture text -----**<br>
4 Configurable inputs/outputs<br>C I/O 1 I/O 2 I/O 3 I/O 4<br>13 15 16 17 18<br>**----- End of picture text -----**<br>
External power supply needed 5-240 VAC/VDC...
**==> picture [30 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 output<br>**----- End of picture text -----**<br>
**==> picture [132 x 38] intentionally omitted <==**
**----- Start of picture text -----**<br>
C Out1 NC NC NC<br>13 15<br>**----- End of picture text -----**<br>
External power supply needed 5-40VDC...
**==> picture [69 x 14] intentionally omitted <==**
**----- Start of picture text -----**<br>
—<br>Communication (C)<br>**----- End of picture text -----**<br>
**==> picture [89 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
RS-485<br>A B C<br>37 36 35<br>**----- End of picture text -----**<br>
**==> picture [56 x 49] intentionally omitted <==**
**----- Start of picture text -----**<br>
M-Bus<br>37 36<br>**----- End of picture text -----**<br>
ARTICLE OR CHAPTER TITLE
65
**—** ABB
With a broad range of marketleading products and solutions, a global sales network and customised support, ABB provides flexibility that improves energy performance, whatever the requirements.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
66
## **—**
## **Circuit Monitoring System - CMS** Technical features
## **—**
## **Control unit CMS 600**
|Control Unit CMS-600 – «Modbus RTU»Unit 600|Control Unit CMS-600 – «Modbus RTU»Unit 600|||
|---|---|---|---|
||Supply voltage|[V DC]|24 (± 10 %)|
||Power input|[W]|4 – 24 (dep. on number of sensors)|
||Interface||RS485 2-wire|
|a|Protocol||Modbus RTU|
|4|Data rate|[Baud]|2400 ... 115200|
||Refresh time||≤1 sec with max. 64 sensors|
||Insulation strength|[V AC]|400|
||Screw-type terminals||0.5 ... 2.5 mm2, max. 0.6 Nm|
||Mounting method||35 mm DIN rail (DIN 50022) or SMISSLINE TP plug base|
||Dimensions|[mm]|71.8 x 87.0 x 64.9 (4 WM)|
||Operating temperature|[°C]|− 25 ... +70|
||Bearing temperature|[°C]|− 40 ... +85|
||Standards||IEC 61010-1 UL 508/ CSA C22.2 No. 14|
## **—**
## **Control unit CMS 700**
|Control Unit CMS-700||||
|---|---|---|---|
||Supply voltage|[V AC]|80 – 277 (L1-N, +5%)|
||Frequency|[Hz]|50 / 60|
||Power input (L1-N)|[W]|5 ... 40 (dep. on number of sensors)|
||Power input, current transformer,|||
||secondary side|[VA]|Current circuit <2 (per phase)|
||Voltage measurement range|[V AC]|80 – 277 (L1, L2, L3-N)|
||Measurement range, current transformer,|[A]|nominal: 5, max.: 6|
||Harmonic component|[Hz]|up to 2000|
||Data rate of Modbus RTU|[Baud]|RS485 2-wire, 2400 ... 115 200|
||Refresh time||≤1 sec with max. 96 sensors|
||LAN|[Mbit/s]|100|
||Conductor cross-section|[mm2]|0.5 ... 2.5|
||Mounting method||35 mm DIN rail (DIN 50022)|
||Degree of protection||IP20|
||Dimensions|[mm]|160.0 x 87.0 x 64.9 (9 WM)|
||Operating temperature|[°C]|−25 ... +60|
||Bearing temperature|[°C]|−40 ... +85|
||||IEC61010-1|
||Standards||UL 508/ CSA C22.2 No. 14|
||Main circuit accuracy|||
||Voltage||± 1 %|
||Current||± 1 %|
||Harmonic component||1 %|
||Active power||± 2 %|
||Apparent power||± 2 %|
||Reactive power||± 2 %|
||Power factor||± 0.2 %|
67
CIRCUIT MONITORING SYSTEM - CMS - TECHNIC AL FE ATURES
## **—**
## **Circuit Monitoring System - CMS** Technical features
## **—**
## **Open-core sensors 18 mm**
|||Sensor type||CMS-120xx|CMS-121xx<br>CMS-122xx||
|---|---|---|---|---|---|---|
|CMS 120PS|CMS 120PS|Measurement range||[A]<br>80|40<br>20||
|[||2<br> =@|Measuring method<br>Peak factor, distorted waveform||≤ 1.5|TRMS, AC 50 / 60 Hz, DC<br>≤ 3<br>≤ 6||
||||AC accuracy (TA = + 25 °C)*|||≤ ± 1 %||
|||AC temperature coefficient*|||≤ ± 0.04 %||
|CMS 120DR|CMS 120DR|DC accuracy (TA = + 25 °C)*||≤ ± 1.2 %|≤ ± 1.4 %<br>≤ ± 1.8 %||
|||DC temperature coefficient*||≤ ± 0.14 %|≤ ± 0.24 %<br>≤ ± 0.44 %||
|||Resolution||[A]|0.01||
||=p|Sampling rate, internal||[Hz]|5000||
|||Response time (±1 %)||[sec]|typ. 0.34||
|||Conductor penetration||[mm]|9,6||
|||Insulation strength|||690 AC /1500 DC||
|CMS 120DR|CMS 120DR|Operating/storage temperature||[°C]|− 25 ... +70 / − 40 ... + 85||
||||CMS-120PS Serie|**[mm]**|17.4 x 41.0 x 26.5||
|||Dimensions|CMS-120CA Serie|**[mm]**|17.4 x 41.0 x 29.0||
||||CMS-120DR Serie|**[mm]**|17.4 x 51.5 x 43.2||
|||Standards||IEC 61010-1 | UL508 / CSA C22.2 No 14|IEC 61010-1 | UL508 / CSA C22.2 No 14||
*All accuracy specifications refer to the relevant full scale value and apply to 25 °C. In the case of open-core sensors, the position of the cable influences the precision.
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
68
## **—**
## **ESB installation contactors** Technical features
## **—**
## **ESB installation contactors technical features**
|Main Pole - Utilization Characteristics according to IEC|Main Pole - Utilization Characteristics according to IEC|Main Pole - Utilization Characteristics according to IEC||||||
|---|---|---|---|---|---|---|---|
|Contactor types:||AC operated|ESB20/EN20|||||
||AC/DC operated||||ESB24/|ESB40/|ESB63|
||||||EN24|EN40||
|Rated operational voltage Ue max.|||V|250|400|||
|Rated frequency limits|||Hz|50/60||DC or 50/60 Hz||
|Utilization category AC-1 / AC-7a||||||||
|for air temperature close to contactor < 55 °C||for air temperature close to contactor < 55 °C|(NO) A|20|24|40|63|
|Max. rated operational current Ie AC-1 / AC-7a||Max. rated operational current Ie AC-1 / AC-7a|(NC) A|20|24|30|30|
|Rated operational power AC-1/||230 V - 1 phase|(NO) kW|4|5.5|9.2|14.5|
|AC-7a|400 V - 3 phases||(NO) kW|-|16|26|41|
|||230 V - 1 phase|(NC) kW|4|5.3|8.8|6.9|
||400 V - 3 phases||(NC) kW|-|16|26|26|
|Utilization category AC-3 / AC-7b||||||||
|for air temperature close to con-||230 V - 1 phase|A|9|9|22|30|
|tactor < 55 °C<br>Max. rated operational current Ie|400 V - 3 phases||A|-|9|22|30|
|AC-3/AC-7b||||||||
|Rated operational power AC-3/||230 V - 1 phase|kW|1.1|1.3|3.7|5|
|AC-7b|400 V - 3 phases||kW|-|4|11|15|
|Rated making capacity AC-3/AC-7b||||||10 x Ie / AC-3|10 x Ie / AC-3|
|Rated breaking capacity AC-3/AC-7b||||||8 x Ie / AC-3|8 x Ie / AC-3|
|Short-circuit protection for contactors|||A|20|35|63|80|
|gG type fuse||||||||
|Rated short-time withstand cur-||10 s|A|72|72|176|240|
|rent Icw at 40 °C ambient temp.,||||||||
|in free air, from a||||||||
|cold state||||||||
|Heat dissipation per pole||Ie / AC-1/AC-7a|W|1|3|4|6|
|Max. electrical switching fre-|– for AC-1 / AC-7a||cycles/h|300||||
|quency||||||||
||– for AC-3 / AC-7b||cycles/h|600||||
|Electrical durability|– for AC-1 / AC-7a||cycles|150000|150000|150000|150000|
||– for AC-3 / AC-7b||cycles|150000|500000|170000|240000|
|Mechanical durability||– millions of||1.000.000||||
||operating cycles|||||||
ESB INSTALL ATION CONTACTORS - TECHNIC AL FE ATURES
69
## **—**
## **ESB installation contactors** Technical features
## **—**
## **ESB installation contactors technical features**
|**Main Pole - Utilization Characteristics according to IEC**|**Main Pole - Utilization Characteristics according to IEC**|**Main Pole - Utilization Characteristics according to IEC**|**Main Pole - Utilization Characteristics according to IEC**|**Main Pole - Utilization Characteristics according to IEC**|**Main Pole - Utilization Characteristics according to IEC**|**Main Pole - Utilization Characteristics according to IEC**|**Main Pole - Utilization Characteristics according to IEC**|**Main Pole - Utilization Characteristics according to IEC**||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Contactor types:<br>AC operated|||||||||||ESB20/EN20|||||||||||||||||
|AC/DC operated|||||||||||||||ESB24/EN24|||||ESB40/EN40|||||||ESB63|
|Coil operating limits acc. to IEC 60947-||||||||||||||||||||||0.85 ... 1.1 x Uc (at θ m 55 °C)|||0.85 ... 1.1 x Uc (at θ m 55 °C)||0.85 ... 1.1 x Uc (at θ m 55 °C)|
|4-1||||||||||||||||||||||||||||
|Drop-out voltage in % of Uc|||||||||||approx. 20 ... 75 %|||||||||||||approx. 20 ... 70 %||||
|Frequency range|||||||||Hz||50/60||||||||||||||||50/60 or DC|
|Coil consumption<br>Average pull-in|Average pull-in|||||Average pull-in|Average pull-in|VA / W||||8 / 5|||||4 / 4|||||5 / 5|||||65 / 65|
||||value|||value|value|||||||||||||||||||||
|Average holding||||||Average holding|Average holding|VA / W|||3.2 / 1.2|3.2 / 1.2|||||4 / 4|||||5 / 5|||||4.2 / 4.2|
||||value|||||||||||||||||||||||||
|**Main Pole - Utilization Characteristics according to IEC**||||**Main Pole - Utilization Characteristics according to IEC**||||||||||||||||||||||||
|Contactor types:||||||||AC operated|||ESB20/EN20|||||||||||||||||
||||||||AC/DC operated||||||||ESB24/EN24|||||ESB40/EN40|||ESB63|||||
|Connecting capacity (min. ... max.)||||||||||||||||||||||||||||
|Main pole terminals||||||||||||||||||||||||||||
|Rigid<br>oem||||||||1 x mm²|||||||||1.5 ... 10||||||||||1.5 ... 25|
|mz||||||||2 x mm²|||||||||1.5 ... 4||||||||||1.5 ... 10|
|Degree of protection||||||||||||||||||||||||||||
|acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529|||||acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529|||||||||||||||||||||||
|Protection against direct contact in acc. with EN 50274|Protection against direct contact in acc. with EN 50274||||Protection against direct contact in acc. with EN 50274|Protection against direct contact in acc. with EN 50274||||||||||||||||||||||
|||||||||All terminals|||||||||||||||||||IP20|
|**EH04... Auxiliary Contact Block - Utilization Characteristics according to IEC**||||||||||||||||||||||||||||
|Contactor types:||||||||AC operated|||||||ESB20|||||||||||||
||||||||AC/DC operated|||||||||||||ESB24||ESB40|||||ESB63|
|Rated operational voltage Ue max.|||||||||||V||||-|||||500||||||||
|Conventional free air thermal current Ith||||||||||||||||||||||||||||
|q < 40 °C|||||||||||A||||-|||||6||||||||
|Rated frequency limits|||||||||||Hz||||-|||||50/60||||||||
|Rated operational current Ie /|||||||240 V|50/60 Hz|50/60 Hz||A||||-|||||4||||||||
|AC-15 acc. to IEC 60947-5-1|||||||415 V|50/60 Hz|50/60 Hz||A||||-|||||3||||||||
||||||||500 V|50/60 Hz|50/60 Hz||A||||-|||||2||||||||
|Making capacity||||acc. to IEC 60947-5-1|||||||||||-||11 x Ie AC-15|11 x Ie AC-15|11 x Ie AC-15|||||||||
|Breaking capacity||||acc. to IEC 60947-5-1|||||||||||-||11 x Ie AC-15|11 x Ie AC-15|11 x Ie AC-15|||||||||
|Short-circuit protection gI type fuse|||||||||||A||||-|||||10||||||||
|Minimum switching capacity with failure rate acc. to IEC|Minimum switching capacity with failure rate acc. to IEC|||||Minimum switching capacity with failure rate acc. to IEC|Minimum switching capacity with failure rate acc. to IEC||||V/mA||||-|||||17 / 5||||||||
|60947-5-4||||||||||||||||||||||||||||
|Heat dissipation per pole at 6 A|||||||||||W||||-|||||0.1||||||||
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
70
## **—**
## **D Line digital time switches**
## Technical features
## **—**
## **D Line technical features**
|**General data**|||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|||**D1**|**D1**|**D1**<br>**D2**||||**D2**|||**D2 SYNCHRO**||
||||**PLUS**|**SYNCHRO**||||**PLUS**|||||
|Rated voltage|[V]|||||||||230 AC ± 10%|230 AC ± 10%||
|Rated pulsating voltage|[kV]|||||||||||4|
|Contact type||||Contact relay in free exchange from potential|||||||||
|Programming key|||||||||||||
|External input|||||||||||||
|DCF77 antenna|||||||||||||
|GPS antenna<br>Programming software<br>250 V contact capacity||~~_~~||||~~nT~~|||||||
|Ohm loads|[A]||||||||||16 16||
|Inductive loads|[A]||||||||||10 2|10 2|
|Rated frequency|[Hz]||||||||||50-60||
|Time base|||||||||||quartz||
|Minimum switching|[sec.]|||||||||||1|
|Max programs per cycle|[n°]|||||64 (can be coupled in day blocks)|64 (can be coupled in day blocks)|64 (can be coupled in day blocks)|||||
|Running reserve|[year]|||6 from the first start-up (lithium battery)|6 from the first start-up (lithium battery)||6 from the first start-up (lithium battery)|6 from the first start-up (lithium battery)||6 from the first start-up (lithium battery)|||
|External input|[n°]||1||-||||2|||-|
|Activity suspension||||||||From 1 day to 12 months|||||
|Operating precision|[sec./||||||||||± 0.5||
||day]||||||||||||
|Max. dissipated power|[VA]|||6.5|||||||7.8||
|Max. switch power|[VA]||||||||||3500||
|Incandescent lamps|[W]||||||||||3000||
|Non-rephased fluorescent|[W]||||||||||1100||
|lamps|||||||||||||
|Fluorescent tube lamps|[W]||||||||||900||
|rephased in parallel|||||||||||||
|Fluorescent tube lamps with|[W]|||||||7 ÷ 23 (max. 23 lamp.)|7 ÷ 23 (max. 23 lamp.)||||
|electronic reactor|||||||||||||
|Fluorescent tube lamps|[W]||||||||||1100||
|rephased in series|||||||||||||
|Protection degree|[IP]||||||||||20||
|Max. terminal cross-section|[mm²]|||||||||||6|
|Terminals||||||In positive safety with captive screw||In positive safety with captive screw|||||
|Tightening torque|[Nm]||||||||||0.5||
|Installation type|||||||||||DIN rail||
|Operating temperature|[°C]||||||||||-5 … +55||
|Storage temperature|[°C]||||||||||-10 … +65||
|Modules|[n°]|||||||||||2|
|Reference standards|||||||EN 60730-1; EN 60730-2-7||||EN 60730-1; EN 60730-2-7||
T LINE T WILIGHT SWITCHES - TECHNIC AL FE ATURES
71
## **—**
## **T Line twilight switches** Technical features
## **—**
## **T1 technical features**
|**General data**|||||||
|---|---|---|---|---|---|---|
||||||**T1**|**T1 PLUS**|
|Rated supply voltage||||[V]||110 ÷ 230 AC|
|Contact type||||||1NO|
|Switching capacity|||||||
|resistive load cosj 1||||[A]||16|
|inductive load cosj 0.6||||[A]||3|
|incandescent lamps||||cosj 1||max 3600 W|
|fluorescent lamps||||cosj0.8||max 3600 W|
|fluorescent - duo./electronic lamps||||cosj0.9||max 300 W|
|Rated frequency||||[Hz]||50-60|
|Switching delay|||||||
|ON||||[s]|30 ±10%|15...120 ±10%|
|OFF||||[s]|40 ±10%|15...120 ±10%|
|Brightness range||||[lx]|2:200|2:40|
|||||||20:200|
|||||||200:2000|
|||||||2000:15000|
|Protection degree|||||||
|twilight switch|||||IP20|IP20|
|sensor|||||IP65|IP65|
|Operating temperature|||||||
|twilight switch||||[°C]||-25…+55|
|sensor||||[°C]||-40...+70|
|Storage temperature|||||||
|twilight switch||||[°C]||-40...+70|
|sensor||||[°C]||-50...+80|
|Power consumption||||[VA]||4.5|
|Max. commutable power||||[W]||3500|
|Max. terminal cross-section||||[mm²]||2.5|
|Terminals||||||loss-proof screw|
|Tightening torque|||terminals|[Nm]||0.5|
||||sensor screw|[Nm]||0.4|
||||Mounting|||on DIN rail|
|Switching status indication/||||||red Led / green Led|
|||brightness range|||||
||Max wiring length|||[m]||100|
||||Modules|||1|
|Reference standards|||||EN 60669-1; EN 60669-2-1; EN 60730-1||
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
72
## **—**
## **T1 & T1 PLUS twilight switch** Control and automation technical features
> — — 01 Daytime
—
## T1 twilight switch
02 Evening operation
## **Operating principle**
## **Example of installation**
—
03 Late evening mode The diagram shows an example of the installation of the T1 twilight switch in the lighting system of a commercial establishment. When the external light falls below a certain level (e.g. during the evening when the shop is closed), the device switches on the window lights and the shop sign. The lights can be switched off late evening to reduce power consumption thanks to the AT1 switch timer.
## **Application environments**
The installation of the T1 twilight switch with an AT electromechanical timer is particularly useful in settings and situations where energy saving is a prime concern (shops, office corridors and public passageways, car parks, parks, etc.).
As shown in the diagrams, one of the possible applications is the installation of a T1 twilight switch in the lighting system of a commercial establishment.
When the external light falls below a certain level (e.g. when the shop is closed), the twilight switch switches on the window lights and the sign. The lights can be switched off late evening to reduce power consumption thanks to the AT1 switch timer which keeps the circuit open until the next morning. When the external light returns to above the threshold value, the twilight switch relay returns to the open position.
**==> picture [146 x 102] intentionally omitted <==**
**----- Start of picture text -----**<br>
AUXILIARY L1 N<br>sensor<br>-<br>fe7<br>T1 AT1<br>**----- End of picture text -----**<br>
**==> picture [172 x 152] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>3 3<br>iF<br>AT1 T11<br>AUXILIARY 4 1<br>L<br>T1<br>[or N G I<br>N<br>LIGHTING<br>**----- End of picture text -----**<br>
—
**==> picture [9 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
01<br>**----- End of picture text -----**<br>
**==> picture [8 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
—<br>03<br>**----- End of picture text -----**<br>
— 02
T1 & T1 PLUS T WILIGHT SWITCH CONTROL AND AUTOMATION - TECHNIC AL FE ATURES
73
**==> picture [8 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
—<br>04<br>**----- End of picture text -----**<br>
**==> picture [8 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
—<br>05<br>**----- End of picture text -----**<br>
—
04 Required light levels
—
05 Excessive light levels
## —
## T1 PLUS twilight switch
## **Operating principle**
The diagram shows an example of the installation of the T1 PLUS twilight switch in the lighting system of a greenhouse. When the external light exceeds a certain level (e.g. during the warmest hours of the day, i.e. early afternoon), the device activates the shading system, e.g. roller blinds. Thanks to the option to advance or delay the activation-deactivation time, the T1 PLUS can also maintain the roller blinds closed in the case of passing clouds.
## **Example of installation**
As shown in the diagrams, one of the possible options is to install a T1 PLUS twilight switch in the lighting system of a greenhouse. When the external light exceeds a certain level (for example during peak hours in the early afternoon) the twilight switch activates the roller blinds, protecting the plants in the greenhouse against burning by the strong sunlight.
## —
## **Application environments**
The installation of the T1 PLUS twilight switch is particularly useful in settings and situations where lighting control is required for locations where there are consistently high brightness values, thus guaranteeing substantial savings in energy consumption (greenhouses, arcades, photovoltaic plants, etc.).
**==> picture [156 x 103] intentionally omitted <==**
**----- Start of picture text -----**<br>
AUXILIARY L1 N<br>sensor<br>T1 PLUS<br>**----- End of picture text -----**<br>
When the external light returns to below the threshold value, the twilight switch relay opens the blinds to allow the sunlight to pass through.
**==> picture [199 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
L1<br>3<br>T1 PLUS<br>AUXILIARY 1<br>L<br>T1 PLUS<br>N LN<br>iI N ne<br>**----- End of picture text -----**<br>
LIGHTING
**PROTECTA PLUS** MCB DISTRIBUTION BOARD 250A
74
## **—**
## **Glossary**
## Detailed product information
## **—**
## **MDRC Products ( MCB etc )**
|**Brochure title**|**Link**|**Order code**||
|---|---|---|---|
|Solutions for electrical||||
|installation in buildings|http://search-ext.abb.com/library/Download.aspx?DocumentID=9AKK10|2CHC 000 001 C0201 - 03/2017||
|(Catalogue) 2017|6930A8017&LanguageCode=en&DocumentPartId=&Action=Launch|( 9AKK106930A8017 )||
|Solutions for electrical||||
|installation in buildings|http://search-ext.abb.com/library/Download.aspx?DocumentID=9AKK10|2CHC 000 001 C0201 - 03/2017||
|(Technical details) 2017|6930A8027&LanguageCode=en&DocumentPartId=&Action=Launch|( 9AKK106930A8027 )||
## **Additional information**
We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.
We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AG.
75
## **—**
## **ABB Limited**
Electrification Products Division Tower Court Foleshill Enterprise Park Courtaulds Way Coventry CV6 5NX Tel: +44 (0) 333 999 9900 E-Mail: LV.Enquiries@gb.abb.com Twitter: @ABBUKEP
## **new.abb.com/uk/protecta-plus**
© Copyright 2017 ABB. All rights reserved. Specifications subject to change without notice.
Updated at April 28, 2026
ABB is a global leader in power and automation technologies, recognized for delivering innovative solutions that improve performance while minimizing environmental impact. Serving a diverse range of sectors including industrial processing, OEM, and building services, ABB provides highly reliable components designed to meet the rigorous demands of modern electrical systems. The company is particularly renowned for its advanced circuit protection solutions. This includes a comprehensive selection of thermal magnetic circuit breakers, alongside specialized RCBO, RCD, GFCI, and AFDD circuit breakers. These foundational safety components are supported by a wide array of high-quality fuse holders and circuit breaker accessories, ensuring complete protection for complex industrial and commercial installations. Beyond circuit protection, ABB excels in automation and process control. Their offering features sophisticated visual signal indicator units, industrial switch accessories, and panel instrumentation designed for intuitive system monitoring. Additionally, ABB manufactures a robust range of power relays, safety relays, and AC/DC converters, providing engineers with the critical building blocks needed for efficient, secure, and reliable control panels.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →