Image not available
Illustrative purposes only
EDT1411-NTC-247
Thermostat, EDT1411 Series, NTC, 24 Vac/dc, 8A Relay Output
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CAL CONTROLS
- Product type: Temperature Controllers
- Thermocouple Type:NTC; Operating Temperature Max:50°C; Operating Temperature Min:0°C; Temperature Accuracy ±:-; Output Voltage Max:250VAC; Output Voltage Min:-; Product Range:EDT1411-NTC
- Product Range: EDT1411-NTC
- Thermocouple Type: NTC
- Output Voltage Max: 250VAC
- Output Voltage Min: -
- Temperature Accuracy ±: -
- Operating Temperature Max: 50°C
- Operating Temperature Min: 0°C
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 49.43 € |
| Current stock | 10+ |
| Lead time | 30 days |
Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. CAL Controls shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. ## **CAL EDT1411 THERMOSTAT** Thank you for choosing the CAL EDT1411 thermostat. - **34 x 77mm sized.** - **On-Off control.** - **°F** ~~a~~ - *** Single contact output for cooling control.* NTC probe input for cold room temperature. °C * Offset value can be entered for NTC probe. SET * Compressor protection parameters can be entered. * In the case of probe failure, output state can be** BV. **selected on or off or periodical running.** CAL **EDT1411** - **Upper and lower limits of the setpoint can be adjusted.** - **Defrosting duration and interval can be adjusted.** - **16 different warning tones.** - **Upper and lower limits of the alarm value can be adjusted depending on the setpoint value.** - **CE marked according to European Norms.** ## **Order Code :** **1 2** **1 - Supply Voltage 2 - Output** 230VAC...230V AC P..........Relay-16A 24............24V AC/DC None...Relay-8A 12............12V AC/DC ## **Connection Diagram** CAL EDT1411 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The electrical connections must be carried out by qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. The cables should not be close to the power cables or components. **==> picture [363 x 188] intentionally omitted <==** **----- Start of picture text -----**<br> www.cal-controls.com www.cal-controls.com www.cal-controls.com<br>EDT1411-NTC-230VAC EDT1411-NTC-24 EDT1411-NTC-230VAC-P<br>DIGITAL DEFROST THERMOSTAT DIGITAL DEFROST THERMOSTAT DIGITAL DEFROST THERMOSTAT<br>SN: XXXXXXXXX SN: XXXXXXXXX SN: XXXXXXXXX<br>C E<br>[o] CfaE C[5€<br>NTC NTC NTC<br>SENSOR SENSOR SENSOR<br>W R W R W R<br>1 a4, 2 3 4 5 6 7 8 9 10 11 9A 12 1 2 3 4 5 4, 6 7 8 9 10 11 9 12 1 2 3 4 5 A, 6 7 8 9 10 11 Gp 12<br>Holding screw Equipment is protected throughout<br>0.4-0.5Nm. by DOUBLE INSULATION<br>NOTE: Fuse<br>SUPPLY: — = F 100 mA 8 Note:<br>250V AC Switch 1) Mains supply cords shall meet the requirements of<br>184-253V AC50/60Hz 3VA 78 ¢ — NeutralLine 230V ACSupply 2) In accordance with the safety regulations, the powerIEC 60227 or IEC 60245.supply switch shall bring the identification of the<br>He > Fuse shouldbe connected Cable size: 1,5mm² relevant instrument and it should be easilyaccessible by the operator.<br>COMPRESSOR 250V AC 8A RESISTIVE LOAD COMPRESSOR 250V AC 16A RESISTIVE LOAD<br>3VA ±<br>COMPRESSOR 250V AC 8A RESISTIVE LOAD<br>230V AC +10% -20% 50/60Hz<br>10%<br>3VA<br>24V AC/DC 50/60Hz<br>3VA<br>230V AC +10% -20% 50/60Hz<br>**----- End of picture text -----**<br> **Technical Specifications** Ce **ENVIRONMENTAL CONDITIONS Ambient/storage temperature 0 ... +50°C/-25 ... 70°C (with no icing)** ae **Max. relative humidity 80%, up to 31°C decreasing linearly 50% at 40°C Rated pollution degree According to EN 60529 Front panel : IP60** ee **Rear panel : IP20** a **Height Max. 2000m Do not use the device in locations subject to corrosive and flammable gasses.** ## **ELECTRICAL CHARACTERISTICS** |**ELECTRICAL CHARACTERISTICS**|**ELECTRICAL CHARACTERISTICS**| |---|---| |**Supply voltage**<br>**230V AC +%10 -%20,**|**230V AC +%10 -%20,50/60Hz or 24V AC/DC ±%10, 50/60Hz or 12V AC/DC ±%10, 50/60Hz.**| |**Supply voltage**<br>**230V AC +%10 -%20,**<br>**Power consumption**<br>**Max. **|**230V AC +%10 -%20, 50/60Hz or 24V AC/DC ±%10, 50/60Hz or 12V AC/DC ±%10, 50/60Hz.**<br> **3VA**| |**2.5mm² screw-terminal connections.**<br>**Wiring**<br>**Scale**<br>**-50.0 ... +110.0°C (-58.0 ... +230.0°F)**|**2.5mm² screw-terminal connections.**<br>**-50.0 ... +110.0°C (-58.0 ... +230.0°F)**| |**Scale**<br>**Sensitivity/Accuracy**<br>**-50.0 ... +110.0°C (-58.0 ... +230.0°F)**<br>**0.1°C /**|**-50.0 ... +110.0°C (-58.0 ... +230.0°F)**<br>**0.1°C /**<br>**°C**<br>±**1**| |**( %1-15sec) for hour unit, (**<br>±<br>**Sensitivity/Accuracy**<br>**Time Accuracy**|**%1-15sec) for hour unit, ( %1-1sec) for minute unit**<br>±| |**4 digits, 12mm, 7 parts yellow LED**<br>**Indicator**|**4 digits, 12mm, 7 parts yellow LED**| |**4 digits, 12mm, 7 parts yellow LED**<br>**EMC**<br>**EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.**<br>**The device is designed to operate in controlled**|**4 digits, 12mm, 7 parts yellow LED**<br>**EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.**<br>**The device is designed to operate in controlled electromagnetic environment)**| |**Safety requirements**<br>**EN 61010-1: 2001**|**EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)**| **Safety requirements EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)** Ce **OUTPUT COMPRESSOR For EDT1411-NTC-XX for resistive load), NO+NC;** **==> picture [370 x 329] intentionally omitted <==** **----- Start of picture text -----**<br> COMPRESSOR For EDT1411-NTC-XX ; Relay: 250V AC, 8A (for resistive load), NO+NC;<br>1/2 HP 240V AC Cos = 0.4 (for inductive load)<br>For EDT1411-NTC-XXP; Relay: 240V AC, 16A (for resistive load), NO;<br>1 HP 230V AC Cos = 0.5 (for inductive load)<br>Life expectancy for relay For EDT1411-NTC-XX ; Mechanical 30.000.000; Electrical 100.000operation.<br>i ee For EDT1411-NTC-XXP; Mechanical 30.000.000; Electrical 30.000operation.<br>CONTROL<br>Control type Single-setpoint control<br>Control algorithm On-Off control<br>Hysteresis Adjustable between 0.1 ... 20.0°C.<br>HOUSING<br>Housing type Suitable for panel mounting.<br>Dimensions W77xH34xD70mm<br>ee<br>Weight Approx. 250g (after packing the device and a probe)<br>Enclosure material Self extinguishing plastics<br>While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used.<br>a Ra|<br>Dimensions Depth<br>85mm For removing mounting clamps: 70mm 8mm<br>°F Push out the mounting clamp<br>°C in direction 1 as shown<br>SET in the figure below. Then, pull<br>out the clamp in direction 2.<br>| 220 CAL av. EDT1411 mounting mounting —————oii)<< 2 Panel Rubber<br>0 ( clamp clamp gasket<br>1<br>Panel cut-out Note :1) Panel thickness<br>71mm should be maximum<br>VSSLOOOOSSSSS)ey<br>a > 7 mm.<br>2) If there is no 60mm<br>free space at the back<br>side of the device, it<br>would be difficult to<br>gtL s | remove it from the<br>panel<br>29mm<br>34mm<br>50/60Hz<br>3VA 8 A 250V AC 250V AC 8A COMPRESSOR<br>230V AC +10% -20% RESISTIVE LODCos= 1 1/2HP 240V AC Cos COMPRESSOR<br>= 0.4<br>12 11 10 9 8 7 6 5 4 3 2 1<br>W R<br>SENSOR<br>NTC<br>SN: XXXXXXXXX<br>DIGITAL DEFROST THERMOSTAT<br>EDT1411-NTC-230VAC<br>www.cal-controls.com<br>**----- End of picture text -----**<br> ~~LY~~ **CAL CONTROLS LTD** ~~B~~ **Bury Mead Road, Hitchin, Herts, SG5 1RT, UK.** n **Tel : +44 (0) 1462 436161 Fax : +44 (0) 1462 451801 e-mail: sales@cal-controls.co.uk Web : www.cal-controls.com** **1/3** **EDT1411-E-06** **FAHRENHEIT DEFROST COMPRESSOR LED LED LED Displayed process value in the run mode, parameter name or value in programming mode. °F When held down for 3 second in the run mode, manual defrost starts. After the specified time with D.dur parameter manual defrost finishes. When held down for 3 second manual defrost finishes before the °C specified time ends. Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates. SET When held down for 3 second in the run mode continuous mode starts. After the specified time with C.Con parameter this mode finishes. When held down for 3 second continuous mode finishes before the specified time ends. Used for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the** CAL **EDT1411 change rate accelerates. SET** **==> picture [735 x 89] intentionally omitted <==** **----- Start of picture text -----**<br> Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. While holding key, setpoint value of the selected parameter appears and by<br>using and keys the value can be adjusted.<br>AY .<br>Run Mode Error Messages<br>- Process - - - Psc Means, thermostat probe is short circuit or temperature value ishigher than the scale.higher than the scale..<br>1000 22.0 Value 30.0 29.9 30.0<br>While holding a key COMPRESSOR setpoint value appears and by using A and Y keys Pfa Means, thermostat probe is broken or temperature value islower than the scale.lower than the scale..<br>the value can be adjusted.<br>SET SET<br>SET<br>**----- End of picture text -----**<br> **==> picture [748 x 442] intentionally omitted <==** **----- Start of picture text -----**<br> Run Mode Error Messages<br>- Process - - - Psc Means, thermostat probe is short circuit or temperature value ishigher than the scale.higher than the scale..<br>1000 22.0 Value 30.0 29.9 30.0<br>While holding a key COMPRESSOR setpoint value appears and by using A and Y keys Pfa Means, thermostat probe is broken or temperature value islower than the scale.lower than the scale..<br>the value can be adjusted.<br>23.5 If process value flashes and warning tone sounds, means,<br>If both keys are pressed and held for 3 seconds, If both keys are pressed, measured value exceeds the adjusted alarm limit.<br>4 programming mode is entered. ’ run mode is entered. Lane]<br>*Note: To stop warning tone, press any key.<br>Programming Mode<br>RE CP DE Al SE<br>Vv Vv v Vv Vv<br>The lower limit Delay time for the compressor Defrosting duration. Limit for Access code for security menu.<br>R.lol of the setpoint. C.pon after power is on. D.dur A.lol lower alarm level. S.Cod This parameter should be 321 .<br>_ = _<br>Vv Vv Vv Vv Vv<br>The upper limit Delay time required for Interval between Limit for Security parameter<br>R.uPl of the setpoint. C.Fos the compressor to restart D.int defrost cycles. A.uPl upper alarm level. A. - re for refrigeration menu<br>following a stop.<br>oo _ _ =<br>Vv Vv Vv Vv Vv<br>The offset value Continuous-on mode duration Display configuration Time delay to display Security parameter<br>R.off for the refrigeration. C.Con for the compressor. D.dsp during defrost A.dFl alarm message afteralarm is on. A. - Cp for menu of compressor control<br>_ _ _ _ _<br>Vv Vv Vv Vv Vv<br>Switch hysteresis on time for the compressor Delay time for display Switch hysteresis Security parameter<br>R.Hys for compressor. C.ppn output in the case ofprobe failure. D.drE real temperature afterdefrost is over. A.HYS for alarm. A. - de for menu of defrost control<br>_ _ _ _ _<br>Vv Vv Vv Vv Vv<br>Temperature unit oFF time for the compressor Defrosting after Alarm configuration Security parameter<br>Unit C.ppF output in the case ofprobe failure. D.Pon power is on. A.Set A. - al for menu of alarm control<br>_ _ _ _ —<br>Vv Vv Vv Vv Vv<br>Display resolution Delay time for defrosting Time delay to display Security parameter<br>DrES D.dPo after power is on. A.dpo alarm message after A.rE.S. for refrigeration setpoint value<br>_ _ _ power is on. _<br>Vv Vv Vv Vv<br>Type of buzzer<br>SonD sound.<br>_<br>SET SET<br>SET<br>**----- End of picture text -----**<br> **2/3** **EDT1411-E-06** **EDT1411 OUTPUT AND PARAMETER TABLE** **==> picture [530 x 784] intentionally omitted <==** **----- Start of picture text -----**<br> Power<br>D.dPo<br>(if d.Pon = y,<br>then d.dPo<br>timer runs)<br>D.int<br>D.dur<br>C.Con<br>DefrostLED Defrost mode<br>Compressor<br>LED<br>CompressorOutput C.Pon Continuous mode<br>AHi enable AHi disable Alo enable Alo disable<br>A.uPl<br>A.uPl-A.HYS<br>SET+ r.HYS<br>SET<br>A.LoL+A.HYS<br>A.LoL<br>A.dPo<br>A.dFL<br>Alarm<br>status<br>NOTE : Variables for lower and upper alarm level are determined according to A.SEt parameter. If A.SEt = A.AbS ,then A.LoL = A.LoL & A.uPL = A.uPL.<br>If A.SEt = A.rEF , then A.LoL = SET-ALoL & A.uPL = SET+A.uPL.<br>RE Menu of Refrigeration control parameters MÝN MAX UNIT DEF.SET<br>R.LoL The lower limit of the setpoint. -50.0 R.uPL °C -50.0<br>R.uPL The upper limit of the setpoint. R.LoL 110.0 °C 110.0<br>R.oFF The offset value for the refrigeration. -20.0 20.0 °C 0.0<br>R.HYS Switch hysteresis for compressor. 0.1 20.0 °C 0.1<br>Unit Temperature unit °C °F °C<br>DrES Display resolution (n= no decimal point, y= with decimal point.) N Y N<br>Sond Type of buzzer sound ( 16 different warning tones can be selectable. If Sond=0, then warning tone is disable.) 0 16 0<br>CP Menu of Compressor control parameters<br>C.pon Delay time for the compressor after power is on. 0 255 min. 1<br>C.FoS Delay time required for the compressor to restart following a stop. 0 255 min. 1<br>C.Con Continuous-on mode duration for the compressor. 0.0 24.0 h. 0.1<br>C.PPn on time for the compressor output in the case of probe failure. 0 255 min. 0<br>C.PPF oFF time for the compressor output in the case of probe failure. 0 255 min. 1<br>DE Menu of Defrost control parameters<br>D.dur Defrosting duration.(If d.dur=0, then defrost is disable.) 0 255 min. 1<br>D.int Interval between defrost cycles. 1 120 h. 1<br>Display configuration during defrost (rEAL= Real temperature is displayed during defrost.<br>D.dSP dEF= dEF message is displayed during defrost.) REAL DEF DEF<br>D.drE Delay time for display real temperature after defrost is over. 0 255 min. 1<br>D.Pon Defrosting after power is on.(y=Defrosting begins when power is on, n=Defrosting doesn’t begin when power is on.) N Y N<br>D.dPo Delay time for defrosting after power is on. 0 30 min. 1<br>Al Menu of Alarm control parameters<br>A.LoL Limit for lower alarm level. -50.0 A.uPL °C -50.0<br>A.uPL Limit for upper alarm level. A.LoL 110.0 °C 110.0<br>A.dFL Time delay to display alarm message after alarm is on. 0 255 min. 0<br>A.HYS Switch hysteresis for alarm. 0 15 °C 2<br>A.SEt Alarm configuration (A.Abs = Absolute alarm. Alarm values are A.LoL and A.uPL. A.AbS A.rEF A.AbS<br>A.rEF = Relative alarm. Alarm values are SET-A.LoL and SET+A.uPL.)<br>A.dPo Time delay to display alarm message after power is on. 0 23.5 hr. 0.3<br>SE Menu of Parameter security<br>A. - rE Security parameter for refrigeration menu (NonE= menu is invisible, P.yes= Parameters of menu are changeable,P.no= Parameters of menu are only visible.)<br>A. - CP Security parameter for menu of compressor control (NonE= menu is invisible, P.yes= Parameters of menu are changeable,P.no= Parameters of menu are only visible.)<br>A. - DE Security parameter for menu of defrost control (NonE= menu is invisible, P.yes= Parameters of menu are changeable,P.no= Parameters of menu are only visible.)<br>A. - AL Security parameter for menu of alarm control (NonE= menu is invisible, P.yes= Parameters of menu are changeable,P.no= Parameters of menu are only visible.)<br>A.rE.S. Security parameter for refrigeration setpoint value ( P.yes= Setpoint value is invisible.,P.no= Setpoint value is only visible.)<br>**----- End of picture text -----**<br> **EDT1411-E-06** **3/3**
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →