DZ1R08MV1
DIGITAL TIMER, 0.001S - DAYS, 8A, SPDT
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type: Time Delay Relays - Electromechanical
- ; DIGITAL TIMER, 0.001S - DAYS, 8A, SPDT; Contact Voltage VDC:30V; Time Min:0.001s; Time Max:100Days; Product Range:SYR-LINE Series; Contact Configuration:SPDT; Contact Current:8A;
- SVHC: No SVHC (21-Jan-2025)
- Time Max: 100Days
- Time Min: 0.001s
- Product Range: Syr-line DZ1R Series
- Relay Mounting: DIN Rail
- Contact Current: 8A
- Relay Terminals: Screw
- Nom Input Voltage: -
- Timing Adjustment: Screwdriver Slot
- Contact Voltage VAC: 250V
- Contact Voltage VDC: 30V
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 143.18 € |
| Current stock | 10+ |
| Lead time | 30 days |
**|** 11/2019 ## › **Universal Digital Timer DIN Rail Mount 17.5 mm** › **Digital timer (LED Screen)** › **Multifunction (23 base functions + options = 138 functions)** a a › recise time configuration › **Optional features: password setting and time limit setting** - › **2 use modes (basic and advanced)** - › **Programmable without power supply** - › **Wide time range (from 0.1 seconds up to 100 days)** - › **Universal power supply (12-240 V** a **/** c **)** - › **Universal connection** **==> picture [458 x 310] intentionally omitted <==** **----- Start of picture text -----**<br> DZ1R08MV1<br>Multifunction<br>Product selection<br>Type Function Output Supply Voltage Part Number<br>DZ1R Multifunction Z : (A, Ab, Ac, Ad, Ah, 1 relay 12 → 240 V z<br>At, B, Bw, C, D, Di, H, Ht, L, Li, O, N, DZ1R08MV1<br>P, Pt, T, TL, Tt, W) + options<br>PART NUMBERING SYSTEM<br>Function Output Type Power Supply<br>Z: Multifunction Z R: Relay MV1: 12-240 V a / c<br>D Z 1 R 08 MV1<br>Type Output Quantity Output Power<br>D: 17.5 mm Digital 1: 1 Output 08: 8 A<br>**----- End of picture text -----**<br> ## You have a project? Contact us on **www.crouzet.com** ## **Description:** Syr-line, the specialized range at Crouzet, aimed to satisfy the most unique requirements of your applications by innovating in design, engineering and development. The Universal Digital Timer, the new Syr-line timer that fits all your needs. The Universal Digital Timer offers the same ease of use as analog timers but it is powered with visualization, higher-precision and all the functions you need (up to 138). For more information about Crouzet’s Syr-line range, please visit **www.crouzet.com** . **|** CONTROL.CROUZET.COM **| 2** **|** Universal Digital Timer **|** 11/2019 ||**DZ1R08MV1**| |---|---| |**InputSpecifcations**|| |Rated supply voltage Un|12 → 240 Vz| |Voltage supply tolerance|-15 %, +10 %| |AC supply voltage frequency|50 / 60 Hz ± 5%| |Galvanic isolation of supply / inputs|No| |Power consumption @ Un|Approx. 2.5 VA (Va) 1 W (Vc)| |Immunity to power micro cuts<br>**TimingSpecifcations**|10 ms| |Specifed time ranges|0.001 → 9.999 s, 1 s → 99 m 59 s, 1 m → 99 h 59 m, 1 h →99 d 23 h| |Minimum control pulse duration IEC 61812-1|45 ms for PNP mode<br>150 ms for NPN mode| |Recovery time (after by de-energisation) IEC 61812-1|120 ms| |Repeatability IEC 61812-1|≤ 0.5 % ±150 ms<br>**Note:**For COMMAND function of SUM and PAUSE, Repeatability<br>is < 0.5 % ± 250ms| |Setting accuracy IEC 61812-1|≤ 0.5 % ±150 ms<br>**Note:**For COMMAND function of SUM and PAUSE, Setting Accuracy<br>is < 0.5 % ± 250ms| |Temperature drift|≤ 0.5 % ±50 ms| |Voltage drift<br>**OutputSpecifcations**|≤ 0.5 % ±50 ms| |Contact arrangement|1 CO (SPDT) (ChangeOver - Single Pole Double Throw-)| |Maximum switching voltage|250 Va/ 30 Vc| |Switching current rate (resistive)|NO / NC: 8 A 250 Va/ 8 A 30 Vc@ 40 °C<br>NO / NC: 5 A 250 Va/ 5 A 30 Vc@ 50 °C| |Minimum switching contact|10 mA / 5 Vc| |Maximum switching power (resistive)|2 000 VA / 240 W| |Electrical life|105cycles min at 250 Va/ 8 A resistive (NO only)| |Maximum rate (at max switching power)|360 cycles / hour| |Mechanical life|10 x 106cycles| |Rated impulse voltage IEC 60664-1|4 kV (1.2 / 50µs)| |Dielectric strength between coil / contacts IEC 60664-1|2.5 kV /1 min / 1 mA / 50 Hz| |Dielectric strength between open contacts<br>**InsulationSpecifcations**|1 kV /1 min / 1 mA / 50 Hz| |Rated Insulation voltage IEC 60664-1|250 V| |Insulation coordination IEC 60664-1|Overvoltage category III; pollution degree 2| |Rated impulse voltage IEC 60664-1|4 kV (1.2 / 50µs)| |Clearance / Creepage distances (IEC 60664-1|3 mm / 3.2 mm| |Dielectric strength EN-61812-1|2.5 kV /1 min / 1 mA / 50 Hz| |Insulation resistance NFC 93 050<br>**Generalspecifcations**|> 500 MOhms / 250 Vc/ 1min| |Display|1 general control knob| ||128*32 panel matrix OLED display| |Casing DIN 43 880|17.5 mm| |Din rail mounting EN 50022|35 mm symmetrical DIN rail| |Mounting position|All positions| |Housing material UL94|Enclosure plastic type V0| |Degree of protection IEC 60529|Housing: IP40 / Terminal block: IP20| |Terminal capacity single-wire IEC 60947-1 without ferrule|1 x 0.5 → 3.3 mm² (AWG 20 → AWG 12)| |(copper conductors only)|2 x 0.5 → 1.5 mm² (AWG 20→ AWG 16)| |Stripping length|6 mm| |Maximum tightening torques IEC 60947-1|0.5 N.m / 4.4 lbf.in| **|** CONTROL.CROUZET.COM **| 3** **|** Universal Digital Timer **|** 11/2019 ||**DZ1R08MV1**| |---|---| |Operating temperature IEC 60068-2|-20 → +50 °C| |Storage temperature IEC 60068-2|-40 °C → 30 °C Max (for optimal storage time)| |Humidity IEC 60068-2-30|93 % without condensation| |Vibration resistance IEC 60068-2-6|± 0.15mm from 10 Hz → 60 Hz| ||2 g from 60 Hz → 150 Hz| |Shock resistance IEC 60068-2-27|15 gn - 11 ms; 3 x 6 axis (Output non-energized)| ||5 gn - 11 ms; 3 x 6 axis (Output energized)| |Drop to concrete foor IEC 60068-2-32|High: 0.75 m| |Weight|81 g| ||100 g with packaging| |**StandardsSpecifcations**|| |CEE Directive:|| |2014/30/EU|EMC| |2014/35/EU|Low voltage| |Approvals / Marking|CE| ||cULus Listed Industrial Control Equipment| |Security standard IEC 60664-1|Insulation coordination for equipment within low-voltage systems| |Conformity with environmental directives|| |2015/863/UE|RoHS| |1907/2006|Reach| |2012/19/UE|WEEE| |2006/66/CE|Battery Directive| |Product standard IEC 61812-1|Specifed time relays for industrial use| |UL 60947-4-1|Industrial Control Equipment (NRNT- Industrial Control Switches)| |Electromagnetic compatibility|| |IEC 61000-6-2|Immunity for industrial environment| |IEC 61000-6-3|Emission residential environment| |IEC 61000-6-4|Emission industrial environment| |Immunity to electrostatic discharges IEC 61000-4-2|Level III Air ±8 KV / Contact ±6 KV| |Immunity to radiated, radio-frequency, electromagnetic feld|Level III| |IEC 61000-4-3|10 V/m (80 MHz → 1 GHz) 80 % AM (1 kHz)| ||3 V/m (1.4 → 2 GHz) 80 % AM (1 KHz)| ||1 V/m (2 → 2.7 GHz) 80 % AM (1 KHz)| |Immunity to rapid transient bursts IEC 61000-4-4|Level III| ||direct ±2 kV (power supply)| ||capacitive coupling clamp ±1 KV (command input and outputs)| |Immunity to shock waves on power supply IEC 61000-4-5|Level III| ||line-to-earth ±2 kV| ||line-to-line ±1 kV| |Immunity to radiofrequency in common mode IEC 61000-4-6|Level III| ||10 Vrms (0.15 → 80 MHz) 80 % AM (1 kHz)| |Immunity to voltage dips and breaks IEC 61000-4-11|0 % residual voltage / 1 cycle (Crit. B),| ||40 % residual voltage / 10 cycles 50 Hz / 12 cycles 60 Hz (Crit C)| ||70 % residual voltage / 25 cycles 50 Hz / 30 cycles 60 Hz (Crit C)| ||**Short interruptions:**| ||0 % residual voltage / 250 cycles 50 Hz / 300 cycles 60 Hz (Crit C)| **|** CONTROL.CROUZET.COM **| 4** **|** Universal Digital Timer **|** 11/2019 ## ~~ee~~ **DZ1R08MV1** AC/DC main port emissions IEC 61000-6-3 IEC 61000-6-4 - CISPR 16-2-1 (7.4.1), CISPR 16-1-2 (4.3) 0.15 MHz – 0.5 MHz, 66 dB(μV) – 56 dB(μV) quasi-peak, 56 dB(μV) – 46 dB(μV) average - 0.5 MHz – 5 MHz, 56 dB(μV) quasi-peak, 46 dB(μV) average - 5 MHz – 30 MHz, 60 dB(μV) quasi-peak, 50 dB(μV) average CISPR 14-1 0.15 MHz – 30 MHz CISPR 16-2-1 (7.4.1), CISPR 16-1-2 (4.3) 0.15 MHz – 0.5 MHz, 79 dB(μV) quasi-peak, 66 dB(μV) average 0.5 MHz – 30 MHz, 73 dB(μV) quasi-peak, 60 dB(μV) average Radiated emissions IEC 61000-6-3 IEC61000-6-4 ## CISPR 16-2-3 30 MHz – 230 MHz, 30 dB(μV/m) Quasi-peak at 10 m 230 MHz – 1 000 MHz, 37 dB(μV/m) Quasi-peak at 10 m ## **Or:** 30 MHz – 230 MHz, 40 dB(μV/m) Quasi-peak at 3 m in a semi-anechoic chamber 230 MHz – 1 000 MHz, 47 dB(μV/m) Quasi-peak at 3 m in a semi-anechoic **==> picture [495 x 283] intentionally omitted <==** **----- Start of picture text -----**<br> Connections<br>ee<br>Universal connection DZ1R08MV1 2 connections options with the same product: type 1 or type 2<br>U U<br>U<br>+<br>Y1 Y1<br>— eS) mf<br>A1 Y1 A2 A1 Y1 A2<br>A1 Y1 15<br>R 15 15<br>A2<br>16 18 R R<br>15 16 18 15 16 18<br>000 000<br>A2 A2<br>Oo e<br>U: Supply Type 1 Type 2<br>**----- End of picture text -----**<br> Y1: Input signal R: Output relay **Basic Time Chart** ~~Lt~~ **Function A - On-Delay (Delay on make) Function Ab - Delayed Interval** **|** CONTROL.CROUZET.COM **| 5** **|** Universal Digital Timer **|** 11/2019 **Function Ac - On/Off Delay (Delay on make/break)** T1 T2 poy LUA, **Function�Ah�-�Triggered�Flashing�Cycle�(Single�shot�flip-flop)�** **==> picture [104 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function Ad - Delay on Start<br>**----- End of picture text -----**<br> **Function At - Summation time relay** **Function B - Single Shot (One Shot)** qT **Function C - Off-Delay (Delay on break) Function Di - Flasher (Symmetrical) – ON Start Function H - Interval** **Function Bw - Pulse output** **==> picture [170 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function D - Flasher (Symmetrical) – OFF Start<br>**----- End of picture text -----**<br> **|** CONTROL.CROUZET.COM **| 6** **|** Universal Digital Timer **|** 11/2019 **==> picture [193 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> Function Ht - Interval with Memory<br>Cy<br> —<br>nd<br>T=t1+t2 t1 t2<br>Function Li - Repeat Cycle (Asymmetrical) – ON Start<br>**----- End of picture text -----**<br> **==> picture [147 x 143] intentionally omitted <==** **----- Start of picture text -----**<br> Function N - Watchdog<br>tu<br>>R @Lt<br>co<br>><br>Function Pt - Impulse counter (delay on)<br>**----- End of picture text -----**<br> **==> picture [188 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function TL - Latching (Alternating) – Leading Edge<br>**----- End of picture text -----**<br> **==> picture [194 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function L - Repeat Cycle (Asymmetrical) – OFF Start<br>**----- End of picture text -----**<br> **==> picture [115 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function O - Delayed watchdog<br>**----- End of picture text -----**<br> **Function P - Pulse delayed relay** **==> picture [192 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function T - On-Delay (Delay on make): sum of times<br>**----- End of picture text -----**<br> **==> picture [217 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function Tt - Delayed Latching (Alternating) – Leading Edge<br>**----- End of picture text -----**<br> **|** CONTROL.CROUZET.COM **| 7** **|** Universal Digital Timer **|** 11/2019 **==> picture [181 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Function W - Timing after pulse of control contact<br>**----- End of picture text -----**<br> ## ~~Ce~~ **Outline dimensions (mm)** **==> picture [529 x 276] intentionally omitted <==** **----- Start of picture text -----**<br> 70.21 [±0.5]<br>64.63 [±0.3]<br>18 -1 [0] 48.22 [±0.3]<br>| 27.82 [±0.3]<br>|<br>ie SS<br>1<br>2<br>:<br>J<br>4.23 r<br>1 LED Screen<br>2 Select button<br>Keys Function<br>Enter to Timing Change Mode<br>±0.4<br>90 ±0.3 ±0.3<br>67.39 45.11<br>2.79<br>**----- End of picture text -----**<br> **==> picture [434 x 226] intentionally omitted <==** **----- Start of picture text -----**<br> TIME2 TIME2 TIME TIME<br>03 03 03 03<br>MIN MIN MIN MIN<br>35 35 35 35<br>SE GC SE GC SEGSEC SEGSEC<br>05:00 05:00<br>A A<br>IN OUT IN O UT X X<br>O 1 O 2 O 3 O 4<br>1 Run mode<br>2 Press button less than 3 s<br>3 Timing change mode<br>4 Rotate button: change selection / press button: confirm selection<br>**----- End of picture text -----**<br> **|** CONTROL.CROUZET.COM **| 8 |** Universal Digital Timer **|** 11/2019 **==> picture [494 x 294] intentionally omitted <==** **----- Start of picture text -----**<br> Keys Function<br>EE Enter to Programming Mode<br>TIME2 TIME2 PROG PROG<br>03 03<br>MIN MIN BASIC BASIC<br>35 35 ADVAN ADVAN<br>SEGSEC SE GC<br>TEST TEST<br>05:00 05:00<br>A A<br>IN OUT IN OU T EXIT E XIT<br>We oeL<br>3s<br>“ Ce<br>1 2 3 4<br>1 Run mode<br>2 Press button more than 3 s<br>3 Programming mode<br>4 Rotate button: change selection / press button: confirm selection<br>Programming Mode<br>**----- End of picture text -----**<br> ## Basic Mode - **Timer setting in few seconds** **==> picture [287 x 144] intentionally omitted <==** **----- Start of picture text -----**<br> FUNCTION RANGE COUNT MEMORY<br>a<br>G 23 basic functions G Milliseconds ª Days G UP/DOWN G YES/NO<br>Advanced Mode -<br>INPUT TYPE INPUT FUNCTION TIME CHANGE<br>G PNP G NPN PNP G NPN G NPN NPN G OFF G Trigger G Reset OFF G Trigger G Reset G Trigger G Reset Trigger G Reset G Reset Reset G InstantaneousInstantaneous G Max value<br>Programming mode choice PAC SCS G Sum G StopSum G StopG StopStop G At endAt end<br>**----- End of picture text -----**<br> **==> picture [409 x 237] intentionally omitted <==** **----- Start of picture text -----**<br> Advanced Mode - Optional additional parameters<br>INPUT TYPE INPUT FUNCTION TIME CHANGE UPPER LIMIT<br>G PNP G NPN PNP G NPN G NPN NPN G OFF G Trigger G Reset OFF G Trigger G Reset G Trigger G Reset Trigger G Reset G Reset Reset G InstantaneousInstantaneous G Max value<br>PAC SCS<br>G Sum G StopSum G StopG StopStop G At endAt end<br>LOWER LIMIT BRIGHTNESS SCREEN SAVER LOCK DEFAULT RESET<br>ee G Min value | G Low G Medium | G OFF | G OFF G Programming | G Reset all<br>G High G _5S ª 60S G ALL<br>Test Mode<br>OUTPUT DISPLAY MEMORY<br>| G ON/OFF of [|] G TEST G TEST<br>Test mode choice<br>**----- End of picture text -----**<br> ## **Warning:** The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Crouzet Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →