AC/DC Enclosed Power Supply (PSU), Current Calibration, 2 Outputs, 15 VDC, 1.2 A, -15 VDC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: DANISENSE
- Product type: AC / DC Enclosed Power Supplies
- SVHC: No SVHC (27-Jun-2024)
- Product Range: -
- No. of Outputs: 2Outputs
- Output Power Max: -
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 1.2A
- Output Current - Output 2: 1.2A
- Output Current - Output 3: -
- Output Voltage - Output 1: 15VDC
- Output Voltage - Output 2: -15VDC
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 457.25 € |
| Current stock | 10+ |
| Lead time | 30 days |
**DSSIU-1** Complete 1-channel system interface unit for ultra-stable, high precision fluxgate technology current transducers ## **Features** - 1 channel through D-sub-connector - _±_ 15 V, 1.2 A DC supply output - Universal mains input - Measurement read out through 4mm banana connector - Power and status LEDs on front **RoHS** ~~CE~~ ” 2011/65/EU CAof ## **Description** Low noise power supply and interface unit with industry standard D-sub-9 connector for interfacing a range of DC current transducers (DCCTs). With current read out through banana connectors it makes precision current measurement easy and convenient. ## **Applications** - Fluxgate DCCTs - Hall effect DCCTs - Power measurement - Electric vehicle (EV) test bench Housed in a compact metal case and powered by universal mains, the DSSIU-1 is a reliable and complete solution for implementation of fluxgate current sensing technology. - Power measurement and power analysis - Particle accelerators - Current calibration purposes - Precision current sensing All information subject to change without notice 900037 rev. 4 Page 1 of 5 www.danisense.com 2024-07-26 **DSSIU-1** ## **Electrical specifications at 23 °C,** Vs **=** _±_ **15 V supply voltage** |**Parameter**|**Symbol**<br>**Unit**|**Min**<br>**Typ.**<br>**Max**|**Comment**| |---|---|---|---| |AC Input Voltage<br>AC Input Current<br>115 V<br>AC Input Current<br>230 V<br>AC Input Frequency<br>DC Input Voltage|VAC<br>VRMS<br>IAC<br>ARMS<br>IAC<br>ARMS<br>f<br>Hz<br>VDC<br>V|100<br>250<br>0.2<br>0.1<br>50<br>60<br>120<br>250|| |Output Voltage|Ucc<br>VDC<br>Icc<br>A<br>mVRMS|_±_14.5<br>_±_15.5<br>1.2<br>2.5|No load| |Output Current|Icc||| |Output Voltage Ripple|||| |Full Operating temperature range<br>Limited Operating temperature range<br>Storage temperature range|Ta<br>°C<br>Ta<br>°C<br>°C|-20<br>40<br>-20<br>50<br>-20<br>85|To full rated output current<br>Up to 800 mA output current| |Relative humidity<br>Altitude<br>Usage<br>Pollution degree<br>Ingress protection rating<br>Mass<br>Dimensions|%<br>m<br>kg<br>mm|20<br>80<br>2000<br>2<br>IP20<br>0.5<br>130 x 116 x 56|Non-condensing<br>Designed for indoor use| |EMC standard<br>Safety standard|||EN 61326-1:2013-2021<br>IEC 61010-1:2010/A1:2019| ## **Intended use** � To ensure safety protection, only use the device as described by the manufacturer The DSSIU-1 is designed to power current transducers such as Danisense DT, DS, DQ, DN and DM series or similar. Please see the product manual: https://danisense.com/user-manual. - Cleaning only with a damp cloth - Power/unpower the device by plugging/unplugging the mains power cord - Always keep mains power cord accessible ## **Connections** - (Front) D-sub-9 connector for connecting the transducer cable with the DSSIU-1 - (Front) RED 4 mm banana connector for connecting the positive (+) current or voltage reading from the transducer - (Front) BLACK 4 mm banana connector for connecting the negative (-) current or voltage reading from the transducer - (back) 3 pole IEC mains power connector - (back) 4 pin connector to read STATUS and TEDS signals fed through from the transducer ## **Instruction for use** 1. Do not power up the device before all cables are connected. All information subject to change without notice 900037 rev. 4 Page 2 of 5 www.danisense.com 2024-07-26 **DSSIU-1** 2. Place the primary conductor through the aperture of the transducer. 3. Connect a D-sub-9 cable between DSSIU-1 and sensor. 4. Connect a low impedance amperemeter, measuring resistor or power analyzer on the output (4mm red and black connectors). 5. If using a transducer with direct measuremnent output from the transducer housing (DS600UB-10V or similar), AVOID connecting to the black and red bananas on the front of the DSSIU-1. 6. When all connection are secured - connect mains power. 7. Apply primary current. ## **LEDs** The two front panel LEDs indicate 1) the DSSIU-1 is powered. 2) the status signal (if available) from the connected transducer is OK. ## **Pin out description** **==> picture [97 x 84] intentionally omitted <==** **----- Start of picture text -----**<br> 5 Vs-<br>Vs+ 9<br>4 0 V<br>Status+ 8<br>3 0 V<br>TEDS- 7<br>2 TEDS+<br>Out+ 6<br>1 Out-<br>**----- End of picture text -----**<br> ## **Status signal and LED** **==> picture [65 x 47] intentionally omitted <==** **==> picture [25 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> Status+<br>Status-<br>**----- End of picture text -----**<br> Figure 2: Status signal optocoupler ## Figure 1: D-sub-9 female connection pinout - 1 OutMeasurement output negative terminal 2 TEDS+ Positive TEDS terminal 3 0 V 0 V reference voltage 4 0 V 0 V connection for supply voltage 5 VsNegative supply voltage 6 Out+ Measurement output positive terminal 7 TEDSNegative TEDS terminal 8 Status+ Status signal positive terminal (referred to 0V) 9 Vs+ Positive supply voltage When the sensor is operating in normal condition the status pins (Status+ and Status-) are shorted by an optocoupler and the green status LED is ON, see Fig. 2. When a fault is detected, or the power is off, the status pins are opened and the green status LED is OFF. Status signal optocoupler ratings found below: Forward direction: Status+ to Status- (Pin 8 to pin 3) Maximum forward current: 10 mA Maximum forward voltage: 60 V Maximum reverse voltage: 5 V All information subject to change without notice 900037 rev. 4 Page 3 of 5 www.danisense.com 2024-07-26 **DSSIU-1** **==> picture [201 x 340] intentionally omitted <==** **----- Start of picture text -----**<br> 116<br> 130<br> 56<br>**----- End of picture text -----**<br> **==> picture [176 x 86] intentionally omitted <==** Figure 3: Box dimensions All information subject to change without notice 900037 rev. 4 Page 4 of 5 www.danisense.com 2024-07-26 **DSSIU-1** ## **Declaration of Conformity** Danisense A/S Malervej 10 DK-2630 Taastrup Denmark Declares that under our sole responsibility that this product is in conformity with the provisions of the following EC Directives, including all amendments, and with national legislation implementing these directives: Directive 2014/30/EU Directive 2014/35/EU And that the following harmonized standards have been applied EEN 61010-1 (Third Edition):2010, EN 61010-1:2010/A1:2019 EN 61010-2-030:2021/A11:2021 EN 61326-1:2013 All DANISENSE products are manufactured in accordance with RoHS directive 2011/65/EU. Annex II of the RoHS directive was amended by directive 2015/863 in force since 2015, expanding the list of 6 restricted substances (Lead, Hexavalent Chromium, PBB, PBDE and Cadmium) Danisense follows the provision in EN 63000:2018 Place Taastrup, Denmark Date Henrik Elbæk 2022-03-15 All information subject to change without notice 900037 rev. 4 Page 5 of 5 www.danisense.com 2024-07-26
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →