Image not available
Illustrative purposes only
ALE2902M.
AC/DC DIN Rail Power Supply (PSU), ITE, 71 W, 29 VDC, 4.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ELC
- Product type:
- No. of Outputs:-; Output Power Max:71W; Output Voltage - Output 1:29V; Output Current - Output 1:4.5A; Output Voltage - Output 2:-; Output Current - Output 2:-; Output Voltage -
- SVHC: No SVHC (17-Jan-2023)
- Product Range: -
- No. of Outputs: -
- Output Power Max: 71W
- Current, Output 4: -
- Input Voltage VAC: 190V AC to 253V AC
- Input Voltage AC Max: 253V
- Input Voltage AC Min: 190V
- Power Supply Output Type: Fixed
- Output Current - Output 1: 4.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 29VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 104.55 € |
| Current stock | 10+ |
| Lead time | 30 days |
**UNIVERSAL REGULATED OEM MODULAR POWER SUPPLY** ee **ALE2902M** ## **EAN CODE : 3760244880307** ## **5 V TO 29 V REMOTE-SENSING** **PRECISE :** Switching power supply offering a ripple <3mV rms. **UNIVERSAL :** 12 settings in 2 V steps with ±1V adjustment range. **COMPLETE :** 12 or 24 V lead-acid battery charger function and remote sensing. **PRACTICAL :** Charger position and status indicators. **PROTECTED :** against short circuits and reverse polarity. ## 60 WATTS 5 V to 29 V 2,5 A to 24 V 3,5 A to 12 V 4 A to 5 V battery charger 12V or 24 V **==> picture [89 x 31] intentionally omitted <==** **----- Start of picture text -----**<br> aA<br>**----- End of picture text -----**<br> ## **Specifications** ## **Voltage** - Floating outputs on spring terminal block with levers for 2,5 mm2 (AWG12) wires. - Output voltage : adjustable from 5 to 29 V by 12 position switch, and fine adjustment switch positions : 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28 Volts. Fine adjustment range : ± 1 Volt, whatever the switch setting 12 and 24 V lead-acid battery charger positions identified by two LED indicators. - Regulation : < 30 mV at 5 V and < 10 mV at 29 V for a load variation from 0 to 100%. < 1 mV at 29 V @ 2,1 A and < 4 mV at 5 V @ 4 A for ±10% line variation. - < 30 mV at 5 V and < 10 mV at 29 V for a load variation from 0 to 100%. - Dynamic regul. : - < 1% to 29V and < 5% to 5 V for a load change from 10 to 90%. - Ripple : < 3 mV rms including : - < 3 mV peak to peak of the 100 kHz signal - < 4 mV peak to peak of the 100 Hz signal - < 10 mV peak to peak of switching transients - Hold-up time : 25 ms at half load and 12 ms at full load. (190 V line input) - Indicators : Green LED indicator : “power supply operating” Yellow LEDs indicator : “12 V and 24 V battery charger position” Red LED indicator : “status, output fuse broken" or "overheat" The yellow LEDs also indicate battery-backed operation. **Current** - Max I : 4,2 A in short circuit condition 4 A to 5 V, 3,5 A to 12 V, 2,5 A to 24 V and 2,1 A to 29 V - **Battery charger** - Rated capacity of the lead-acid batteries with elctrolyte free : 35 Ah for 12 V and 20 Ah for 24 V. - Minimum capacity of the lead-acid batteries sealed : 10 Ah for 12 V and 7 Ah for the 24 V. (In all the cases, to refer to the note of the batteries manufacturer) **Remote sensing** - Correction of the voltage drop in the wires (4 wires method) • Input on disconnect scribe terminal blocks for 2,5mm2 wires (AWG12) • Correction : Max 3 V (1,5 V per wire) • Ripple : < 30 mV for a load variation from 0 to max. **Power** **==> picture [267 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> • A linear function of voltage from 60 W to 20 W (29 to 5 Volts).<br>Vv<br>30<br>29<br>Protection 28<br>• Against short circuit, by current limit.• Against overcurrent on primary circuit, by fuse. 222624:<br>• Battery reverse polarity protection by output fuse. 20<br>• Against overtemperature, by thermal shutdown. 18<br>• Cover on input output terminal block. 16<br>14<br>12<br>10<br>8<br>6<br>i<br>2<br>° 1 2 3 4°45 =A<br>**----- End of picture text -----**<br> ## **Other specifications** - Safety : Class II, Safety Extra Low Voltage (SELV), complies with EN 61010-1, EN 61010-2-201 and EN 62368-1. - EMC : Complies with EN 61000-6-2 and EN 61000-6-4. - Overvoltage Category : II ; Pollution Degree : 2. - Installation altitude : < 2000 m. - Protection level : IP 30. - Operating temperature : from -25 to +60 °C ; derating : 1 W/°C from +40 °C - Input voltage : 220-240 VAC (190 to 264 Volts), 50-60 Hz. - Mains input : spring terminal block with levers for 2,5 mm², (AWG 12) wires. • Power consumption : 71 W max. • Dielectric strength : 3000 VAC from input to output. • Presentation : modular polycarbonate case (6 x 17.5 mm) screenprinted. • Mounting : Clips package integrated in modular case for DIN rails profile 35x7,5 mm or 35x15 mm. Removable wall mouting integrated to the case for 4mm screws. **67 | www.elc.fr**
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →