Image not available
Illustrative purposes only
AES1135 (24VDC)
Safety Relay, 24 VDC, AES Series, DIN Rail, 2 A, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SCHMERSAL
- Product type: Safety Relays
- Coil Voltage:24VDC; Contact Configuration:-; Product Range:AES Series; Relay Mounting:DIN Rail; Contact Current:2A; Relay Terminals:Screw; Contact Voltage AC Nom:-; Contact Voltage DC Nom:24V; C
- IP Rating: IP20, IP40, IP54
- Coil Voltage: 24VDC
- Product Range: AES Series
- Relay Mounting: DIN Rail
- Contact Current: 2A
- Relay Terminals: Screw
- Contact Material: Silver Nickel
- Contact Configuration: -
- Contact Voltage AC Nom: -
- Contact Voltage DC Nom: 24V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 203.24 € |
| Current stock | 10+ |
| Lead time | 30 days |
20.04.2011 - 17:44:58h **Print** - **Create PDF** - **Create EXCEL file** ## **Datasheet - AES 1135** Guard door monitors and Safety control modules for Emergency Stop applications / Monitoring of electromechanical and non-contact switchgear / AES 113x - Monitoring of BNS range magnetic safety sensors - 1 safety contact, STOP 0 - 2 Signalling outputs (Minor differences between the printed image and the original product may exist!) ## **Ordering details** Product type description AES 1135 Article number 1170036 EAN code 4030661296920 **Approval** Approval BG USA/CAN **Classification** Standards EN ISO 13849-1, IEC 61508 PL up d Control category up 3 PFH value 1.0 x 10-7/h SIL up 2 Mission time 20 Years ## **Approval** ## **Classification** ## **Global Properties** AES 113x Product name ## Standards IEC/EN 60204-1, IEC 60947-5-3, EN 954-1, BG-GS-ET-14, BG-GS-ET-20 Compliance with the Directives (Y/N) Yes Climatic stress EN 60068-2-3, BG-GS-ET-14 Mounting snaps onto standard DIN rail to EN 60715 Terminal designations IEC/EN 60947-1 Materials - Material of the housings Plastic, glass-fibre reinforced thermoplastic, ventilated - Material of the contacts Ag-Ni, 0,2 µm gold flashed Weight 155 g Start conditions Automatic Start input (Y/N) No Feedback circuit (Y/N) No Start-up test (Y/N) No Reset after disconnection of supply voltage (Y/N) Yes Automatic reset function (Y/N) Yes Reset with edge detection (Y/N) No Pull-in delay - ON delay with automatic start adjustable 0,1 / 1.0 s Drop-out delay - Drop-out delay in case of emergency stop < 50 ms ## **Mechanical data** Connection type Screw connection Cable section - Min. Cable section 0,25 mm² - Max. Cable section 2.5 mm² Pre-wired cable rigid or flexible Tightening torque for the terminals 0,6 Nm Detachable terminals (Y/N) No Mechanical life 20.000.000 operations Electrical lifetime 150.000 operations for 230 VAC, 5 A (cos φ = 1) restistance to shock 30 g / 11 ms Resistance to vibration To EN 60068-2-6 10...55 Hz, Amplitude 0,35 mm, ± 15 % ## **Ambient conditions** Ambient temperature - Min. environmental temperature 0°C - Max. environmental temperature + 55°C Storage and transport temperature - Min. Storage and transport temperature - 25°C - Max. Storage and transport temperature + 70°C Protection class - Protection class-Enclosure IP40 - Protection class-Terminals IP20 - Protection class-Clearance IP54 Air clearances and creepage distances To IEC/EN 60664-1 - Rated impulse withstand voltage Uimp 4.8 kV - Overvoltage category III To VDE 0110 - Degree of pollution 2 To VDE 0110 ## **Electromagnetic compatibility (EMC)** EMC rating 10 V/m ## **Electrical data** |Rated DC voltage for controls|| |---|---| |- Min. rated DC voltage for controls|20.4 V| |- Max. rated DC voltage for controls|27.6 V| |Rated AC voltage for controls, 50 Hz|| |- Min. rated AC voltage for controls, 50 Hz|-| |- Max. rated AC voltage for controls, 50 Hz|-| |Rated AC voltage for controls, 60 Hz|| |- Min. rated AC voltage for controls, 60 Hz|-| |- Max. rated AC voltage for controls, 60 Hz|-| |Contact resistance|max. 100 mΩ| |Power consumption|< 5 W| |Type of actuation|DC| |Switch frequency|1 Hz| |Rated insulation voltage Ui|250 V| |Rated operating voltage Ue|24 VDC ±15%| |Thermal test current Ithe|6 A| |Operating current Ie|0,2 A| |Electronic protection (Y/N)|No| ## **Inputs** ## **Monitored inputs** |**Monitored inputs**|| |---|---| |- Short-circuit recognition (Y/N)|optional| |- Wire breakage detection (Y/N)|Yes| |- Earth connection detection (Y/N)|Yes| |Number of shutters|adjustable 1 piece -> 0 piece| |Number of openers|adjustable 1 piece -> 2 piece| |Input resistance|approx. 4000 Ω at GND| |Input signal "1"|10 ... 30 VDC| |Input signal "0"|0 ... 2 VDC| |Cable length|1000 m with 0,75 mm² (for Rated voltage)| ## **Outputs** |Stop category|0| |---|---| |Number of safety contacts|1 piece| |Number of auxiliary contacts|0 piece| |Number of signalling outputs|2 piece| |Switching capacity|| |- Switching capacity of the safety contacts|min. 10 mA, max. 6 A| |- Switching capacity of the signaling/diagnostic outputs|Y1-Y2 = 100 mA| |Fuse rating|| |- Protection of the safety contacts|6 A gG D-fuse| |- Fuse rating for the signaling/diagnostic outputs|short-circuit proof| |Signalling output|Y1: Authorized operation, safety contacts on;| ||Y2: No authorised operation, safety contacts off| |Utilisation category To EN 60947-5-1|AC-15: 230 V / 3 A| ||DC-13: 24 V / 2 A| |Number of undelayed semi-conductor outputs with signaling|| |function|2 piece| |Number of undelayed outputs with signaling function (with|| |contact)|0 piece| |---|---| |Number of delayed semi-conductor outputs with signaling|| |function.|0 piece| |Number of delayed outputs with signalling function (with|| |contact).|0 piece| |Number of secure undelayed semi-conductor outputs with|| |signaling function|0 piece| |Number of secure, undelayed outputs with signaling function,|| |with contact.|0 piece| |Number of secure, delayed semi-conductor outputs with|| |signaling function|0 piece| |Number of secure, delayed outputs with signaling function|| |(with contact).|0 piece| |**LED switching conditions display**|| |LED switching conditions display (Y/N)|Yes| |Number of LED´s|1 piece| ## **Integral system diagnosis ISD** ## Integral system diagnosis ISD - The following faults are registered by the safety monitoring modules and indicated by ISD - Failure of door contacts to open or close - Cross-wire or short-circuit monitoring of the switch connections - Interruption of the switch connections - Failure of the safety relay to pull-in or drop-out - Fault on the input circuits or the relay control circuits of the safety monitoring module ## **Miscellaneous data** Applications **==> picture [53 x 33] intentionally omitted <==** **----- Start of picture text -----**<br> Safety sensor<br>Guard system<br>**----- End of picture text -----**<br> ## **Dimensions** Dimensions - Width 22.5 mm - Height 100 mm - Depth 121 mm ## **notice** Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. ## **notice - Wiring example** To secure a guard door up to PL 3 and Category #03# Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range If one or two external relays or contactors are used to switch the load, the system can then only be classified in Category 3 to EN 954-1, if exclusion of the fault “Failure of the external contactors” can be substantiated and is documented, e.g. by using reliable down-rated contactors. A second contactor leads to an increase in the level of security by redundant switching to switch the load off. Modification for 2 NC contacts: The safety monitoring module can be modified to monitor two NC contacts by bridging the terminals A1 and X1. The short-circuit recognition between connections then becomes inoperative. Expansion of enable delay time: The enable delay time can be increased from 0,1 s to 1,0 s by changing the position of a jumper link connection under the cover of the unit. The wiring diagram is shown with guard doors closed and in de-energised condition. The ISD tables (Intergral System Diagnostics) for analysis of the fault indications and their causes are shown in the appendix. ## **Documents** **Operating instructions and Declaration of conformity** (de) 824 kB, 30.11.2010 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/DE/mrl_aes1135_1136_de.pdf ## **Operating instructions and Declaration of conformity** (fr) 673 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/FR/mrl_aes1135_1136_fr.pdf **Operating instructions and Declaration of conformity** (it) 660 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/IT/mrl_aes1135_1136_it.pdf **Operating instructions and Declaration of conformity** (es) 659 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/ES/mrl_aes1135_1136_es.pdf **Operating instructions and Declaration of conformity** (de) 666 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/DE/mrl_aes1135_1136_de.pdf **Operating instructions and Declaration of conformity** (nl) 658 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/NL/mrl_aes1135_1136_nl.pdf **Operating instructions and Declaration of conformity** (jp) 1 MB, 30.11.2010 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/JP/mrl_aes1135_1136_jp.pdf **Operating instructions and Declaration of conformity** (en) 747 kB, 02.12.2009 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/bedien/EN/mrl_aes1135_1136_en.pdf ## **Wiring example** (99) 17 kB, 22.08.2008 http://127.0.0.1/Bilddata/Si_baust/Aes1135/Schaltun/Maes1l01.pdf ## **Wiring example** (99) 18 kB, 22.08.2008 http://127.0.0.1/Bilddata/Si_baust/Aes1135/Schaltun/Maes1l02.pdf **ISD tables (Intergral System Diagnostics)** (en) 35 kB, 29.07.2008 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/ISD/i_ae2p02.pdf **ISD tables (Intergral System Diagnostics)** (de) 51 kB, 29.07.2008 http://127.0.0.1/Bilddata/Si_baust/Pdf/Aes1135/ISD/i_ae2p01.pdf **Images** Dimensional drawing (basic component) Wiring example Wiring example K.A. Schmersal GmbH, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 20.04.2011 - 17:44:59h Kasbase 1.4.7 DBI
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →