Image not available
Illustrative purposes only
ABC40-1024G
OPEN FRAME AC - DC CONVERTERS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type: AC / DC Open Frame Power Supplies
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 12 |
| Price | 25.16 € |
| Current stock | 200+ |
| Lead time | 30 days |
## **WLT40** The ABC40 Series of open-frame power supplies, with its wide universal 90 – 264 VAC input range and high power density, is available at 40 W of output power and a variety of single and multiple output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. ## **Key Features & Benefits** - 4 x 2 x 1.2 Inch Form Factor - 40 W convection-cooled rating - Single to Triple Outputs - High Efficiency > 85% - Low conducted and radiated noise - No Load Power < 0.3 W - IEC / EN / UL 62368-1 compliant - IEC Protection Class Options: - Class I: Earth pin J4 (no suffix) - Class II: No Earth pin (-2 suffix) - RoHS Compliant - Cover Kit Accessory Available ## **Applications** - Lighting - Industrial Processing - Applied Computing - Instrumentation - Automation Controls - Robotics - Wireless Communication - Test and Measurement ssAges . Del kes:POWER ABC40 Series 2 **1. MODEL SELECTION** |**MODEL 1**<br>**VOLTAGE**<br>**MAX LOAD 2**<br>**MIN LOAD 3**<br>**RIPPLE 4**<br>**POWER**<br>~~ee~~|**MODEL 1**<br>**VOLTAGE**<br>**MAX LOAD 2**<br>**MIN LOAD 3**<br>**RIPPLE 4**<br>**POWER**<br>~~ee~~|**MODEL 1**<br>**VOLTAGE**<br>**MAX LOAD 2**<br>**MIN LOAD 3**<br>**RIPPLE 4**<br>**POWER**<br>~~ee~~|**MODEL 1**<br>**VOLTAGE**<br>**MAX LOAD 2**<br>**MIN LOAD 3**<br>**RIPPLE 4**<br>**POWER**<br>~~ee~~|**MODEL 1**<br>**VOLTAGE**<br>**MAX LOAD 2**<br>**MIN LOAD 3**<br>**RIPPLE 4**<br>**POWER**<br>~~ee~~|**MODEL 1**<br>**VOLTAGE**<br>**MAX LOAD 2**<br>**MIN LOAD 3**<br>**RIPPLE 4**<br>**POWER**<br>~~ee~~| |---|---|---|---|---|---| |ABC40-1005G|5.1 V|8.0 A|0.0 A|1%|40 W| |ABC40-1012G|12 V|3.5 A|0.0 A|1%|40 W| |ABC40-1015G|15 V|2.7 A|0.0 A|1%|40 W| |ABC40-1024G|24 V|1.7 A|0.0 A|1%|40 W| |ABC40-1048G|48 V|0.83 A|0.0 A|1%|40 W| ||V1= 5.2 V|6.0 A|0.5 A|1.5%|| |ABC40-3000G|V2= 12.5 V|2.0 A|0.1 A|1%|40 W| ||V3= -12.8 V|0.5 A|0.0 A|1%|| ||V1= 5.2 V|6.0 A|0.5 A|1.5%|| |ABC40-3001G|V2= 24 V|1.0 A|0.1 A|1%|40 W| ||V3= -12.8 V|0.5 A|0.0 A|1%|| ||V1= 5.2 V|6.0 A|0.5 A|1.5%|| |ABC40-3002G|V2= 15 V|1.5 A|0.1 A|1%|40 W| ||V3= -15 V|0.5 A|0.0 A|1%|| ||V1= 3.3 V|6.0 A|1.0 A|1.5%|| |ABC40-3003G|V2= 5 V|3.0 A|0.1 A|1.5%|40 W| ||V3= -12.8 V|0.5 A|0.0 A|1%|| |COVER-40-XBC5|Metal cover kit accessory|Metal cover kit accessory|||| - 1 Class II version available. Add suffix “-2” at the end of the Model Number - 2 Maximum current per output channel. Do not exceed total output power rating. - 3 Min Load specified to meet cross regulation. - 4 Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. - 5 - When used in Cover Kit, de-rate output power to 70 % under all operating conditions. ## **2. INPUT SPECIFICATIONS** Specifications are for nominal input voltage, 25°C unless otherwise stated. |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Input Voltage|Universal|90 - 264 VAC| |Input Frequency6||47 to 400 Hz| |Input Current|120 VAC:<br>230 VAC:|0.85 A max.<br>0.45 A max.| |No Load Power|Single output models<br>Multi output models|< 0.3 W<br>< 0.5 W| |Inrush Current|120 VAC:<br>230 VAC:|30 A max.<br>60 A max.| |Leakage Current|120 VAC:<br>230 VAC:|< 500 µA<br><1000 µA| |Switching Frequency|Typical|67 kHz| - 6 Safety approved: 47 to 63 Hz **==> picture [51 x 40] intentionally omitted <==** **----- Start of picture text -----**<br> Pea<br>MEEPS »<br>oes.<br>nO} 2H<br>**----- End of picture text -----**<br> belfuse.com/power-solutions tech.support@psbel.com 3 ## ABC40 Series ## **3. OUTPUT SPECIFICATIONS** **==> picture [430 x 200] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |PARAMETER|DESCRIPTION / CONDITION|SPECIFICATION| |Efficiency|[ 7]|Typical|85%| |Hold Up Time|@ 120 VAC typical|>10 ms| |Output Power|[ 8]|40 W| |Line Regulation|± 0.3%| |V1:|± 0.5%| |Load Regulation|V2 & V3:|± 5%| |< 10%,| |Transient Response|50% to 100% load change, 50/60 Hz, 50% duty cycle, 0.1 A/µs| |recovery time < 5 ms| |Rise Time|< 100 ms| |V1:|± 3%| |Set Point Tolerance| |V2 & V3:|± 5%| |Output Voltage Adjustment|V1|± 10%| |Over Current Protection|Typical, above rating|130%| |Over Voltage Protection|Typical, for V1 only|130%| |Short Circuit Protection|Short term, autorecovery| |Cooling|Convection| **----- End of picture text -----**<br> > 7 For ABC40-3003G efficiency is 75% typical > 8 Derate output power linearly to 80% from 90 VAC to 80 VAC input. ## **4. ENVIRONMENTAL SPECIFICATIONS** **==> picture [418 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |PARAMETER|DESCRIPTION / CONDITION|SPECIFICATION| |Operating Temperature|Refer to derating curve, Fig. 1|-20 to 70°C| |-20 to 0°C start-up is guaranteed| |Storage Temperature|-40 to +70°C| |Relative Humidity|Non Condensing|95%| |Altitude|Operating:|10,000 ft.| |Non-Operating:|40,000 ft.| |Reliability|MTBF according to Telcordia -SR332-Issue 3|1.87 million hours| **----- End of picture text -----**<br> Figure 1. Derating Curve De-rate linearly from 100% at 50°C to 75% at 70°C ## AER POWER eg I, Fe. bel SOLUTIONS & **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00281_G ABC40 Series 4 ## **5. EMC SPECIFICATIONS** |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Conducted Emissions|EN 55032-B, CISPR22-B, FCC PART15-B|Pass| |Radiated Emissions|EN 55032 B|Pass| |Input Current Harmonics|EN 61000-3-2|Class A| |Voltage Fluctuation and Flicker|EN 61000-3-3|Pass| |ESD Immunity|EN 61000-4-2|Level 3, Criterion A| |Radiated Field Immunity|EN 61000-4-3|Level 3, Criterion A| |Electrical Fast Transient Immunity|EN 61000-4-4|Level 3, Criterion A| |Surge Immunity|EN 61000-4-5|Level 3, Criterion A| |Conducted Immunity|EN 61000-4-6|Level 3, Criterion A| |Magnetic Field Immunity|EN 61000-4-8|Level 3, Criterion A| |Voltage Dips, Interruptions|EN 61000-4-11|Criterion A & B| ## **6. SAFETY SPECIFICATIONS** |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Isolation Voltage|Input to Output|4000 VAC / VDC| ||IEC60950-1(ed.2), EN 60950-1, UL60950-1 (2nd Edition), CSA C22.2 No. 60950-1 (2nd Edition),|| |Safety Standards|UL 62368-1, 2nd Ed, 2014-12-01 CAN/CSA C22.2 No. 62368-1-14, (2nd Edition), Class1 SELV|| |Agency Approvals|IEC 62368-1:2014, EN 62368-1:2014 ;A11<br>Nemko, UL, C-UL|| |CE mark|Complies with LVD Directive|| ## **7. CONNECTOR & PIN DESCRIPTION** |**CONNECTOR**|**PIN**|**DESCRIPTION / CONDITION**|**DESCRIPTION / CONDITION**|**MANUFACTURER / PN**| |---|---|---|---|---| |AC Input Connector|J1|Pin 1<br>Pin 2<br>Pin 1,2|AC Line<br>AC Neutral<br>V1|Molex: 26-60-4030 or equivalent<br>Mating: 09-50-3031; Pins: 08-50-0106| |DC Output Connector|J2|Pin 3,4<br>Pin 5|RTN<br>V3|Tyco: 640445-6 or equivalent<br>Mating: 647402-6; Pins: 3-647409-1| |||Pin 6|V2|| |Signal Connector|J3|Pin 1<br>Pin 2|+V1 Sense<br>-V1 Sense|Molex: 22-23-2021 or equivalent<br>Mating: 22-01-2021| |Earth (Spade Connector)|J4|||Molex: 19705-4301<br>Mating: 190030001| ## **8. MECHANICAL SPECIFICATIONS** |**PARAMETER**|**DESCRIPTION / CONDITION**| |---|---| |Weight|150 g (0.33 lbs.)| |Dimensions|101.6 x 50.8 x 30.48 mm (4 x 2 x 1.2 inch)| **==> picture [51 x 40] intentionally omitted <==** **----- Start of picture text -----**<br> Pea<br>MEEPS »<br>oes.<br>nO} 2H<br>**----- End of picture text -----**<br> belfuse.com/power-solutions tech.support@psbel.com 5 ## ABC40 Series Figure 2. Mechanical Drawing ABC40-1xxxG Figure 3. Mechanical Drawing ABC40-3xxxG **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00281_G 6 ## ABC40 Series Figure 4. Mechanical Drawing with Cover Kit - **NOTES:** In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: - 1 Stand off, used to mount PCB has OD of 5.4 mm max. - 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. - 3 Washer, if used, to have dia of 6.5 mm max. ## **For more information on these products consult: tech.support@psbel.com** **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. **==> picture [17 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> we<br>**----- End of picture text -----**<br> tech.support@psbel.com
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →