Image not available
Illustrative purposes only
ABC350-1024L
OPEN FRAME AC-DC CONVERTERS POWER SUPPLY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: ABC350 Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 163.93 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **WLP350** The ABC350 Series of open frame power supplies feature a wide universal AC input range of 90 – 264 VAC, offering 350 W of output power in a compact 3 x 5 x 1 inch footprint, with a variety of isolated single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. Key Features & Benefits - 3 x 5 x 1 Inch Form Factor - 350 W with Forced Air Cooling & 200 W with Convection Cooling - • Efficiencies up to 94% - No Load Power < 0.5 W - -40 to 70°C Operating Temperature - 12 V / 0.5 A Fan Output, Thermal Shut-Down Feature - • • • - - - 2.56 Million Hours, Telcordia -SR332-Issue 3 MTBF - IEC/EN/UL 62368-1:2018 (Ed 3.0) Certified IEC/EN 61558 Compliant (Suitable for Household and Similar electrical equipment certified under IEC/EN 60335-1 standards) CCC (China Compulsory Certification approval) - Approved with metal enclosures/accessories - RoHS Compliant ▪ Instrumentation Lighting ▪ ▪ Industrial Applications - Applied Computing - Renewable Energy ▪ Test and Measurement ▪ Automation Control ▪ Wireless Communication ABC350 Series 2 ## **1.** **==> picture [469 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |MAX. LOAD|MAX. LOAD| |MODEL NUMBER|[ 1]|DESCRIPTION|VOLTAGE|POWER| |(CONVECTION)|(375 LFM)| **----- End of picture text -----**<br> ## **2.** Specifications are for nominal input voltage, 25°C unless otherwise stated. **==> picture [428 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |PARAMETER|DESCRIPTION / CONDITION|SPECIFICATION| |Universal|90-264 VAC / 390 VDC| |Input Voltage| |(Derate from 100% at 100 VAC to 90% at 90 VAC)| |Input Frequency|47 - 63 Hz| |115 VAC:|3.6 A max.| |Input Current|230 VAC:|1.8 A max.| |No Load Power|Typical|>0.5 W| |115 VAC:|25 A| |Inrush Current|230 VAC:|45 A| |264 VAC:|75 A| |Leakage Current|Typical|300 µA| |Power Factor|Full Load|> 0.95| |PFC:|70 - 130 KHz| |Switching Frequency|PWM:|50 - 80 KHz| **----- End of picture text -----**<br> **==> picture [204 x 36] intentionally omitted <==** **----- Start of picture text -----**<br> ESR POWER<br>ARRESTyt<br>ctFe:Oy bel SOLUTIONSPROTECTION &<br>**----- End of picture text -----**<br> tech.support@psbel.com 3 ## ABC350 Series ## **3.** |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Output Voltage||12 to 58 V| |Output Power4|With 375 LFM:<br>Convection:|350 W<br>200 W| |Output Adjustment||+/-3%| |Hold-up Time|Full Load:<br>Convection Load:|> 8 ms typical<br>> 14 ms typical| ||48 V, 58 V:|94%| |Efficiency|24 V, 30 V:|93%| |Line Regulation6|12 V, 15 V:|92%<br>+/-0.5%| |Load Regulation6||+/-1%| |Minimum Load||0.0 A| |Transient Response|50-100% step load change, at 0.1A/µS slew rate,<br>50% duty cycle, 50 Hz = 5% ,|recovery time < 5 ms| |Ripple5, 6|For all outputs|1.0 % max| |Rise Time|Typical|55 ms| |Set Point Tolerance6||+/-1%| |Over Current Protection|Hiccup mode / Auto Recovery|>110%| |Over Voltage Protection|Hiccup mode / Auto Recovery|110 to 140%| |Short Circuit Protection|Hiccup mode / Auto Recovery|| |Cooling|With 375 LFM forced air cooling at 100 to 264 VAC:<br>With natural convection cooling at 100 to 264 VAC:|350 W<br>200 W| ## **4.** |Conducted Emissions|EN55032-B, CISPR22-B, FCC PART15-B|Pass| |---|---|---| |Radiated Emissions|EN 55032 A;<br>with external core (King core K5B RC 25x12x15-M in input cable)|Pass<br>Level B| |Input Current Harmonics|EN 61000-3-2|Class D| |Voltage Fluctuation and Flicker|EN 61000-3-3|Pass| |ESD Immunity|EN 61000-4-2|Level 3, Criterion A| |Radiated Field Immunity|EN 61000-4-3|Level 3, Criterion A| |Electrical Fast Transient Immunity|EN 61000-4-4|Level 3, Criterion A| |Surge Immunity|EN 61000-4-5|Level 4, Criterion A| |Conducted Immunity|EN 61000-4-6|Level 3, Criterion A| |Magnetic Field Immunity|EN 61000-4-8|Level 3, Criterion A| |Voltage Dips, Interruptions|EN 61000-4-11|Criterion A & B| **==> picture [47 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> neg tE Gate yt<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00560_AH ABC350 Series 4 ## **5.** |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Isolation Voltage|Input to Output: for ITE application<br>Input to GND:|3000 VAC<br>1500 VAC| ||IEC 62368-1:2018, IEC 61558-1:2005, IEC 61558-1:2005/AMD1:2009, IEC 61558-2-16:2009,|IEC 62368-1:2018, IEC 61558-1:2005, IEC 61558-1:2005/AMD1:2009, IEC 61558-2-16:2009,| ||IEC 61558-2-16:2009 /AMD1:2013, IEC 60950-1(ed.2); am1; am2, EN 61558-2-16:2009; A1,|| |Safety Standards|EN 61558-1:2005; A1,|| ||EN 60950-1:2006; A11; A1; A12; A2, UL 62368-1 and CAN/CSA C22.2 No. 62368-1:19|| ||UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07, GB4943.1-2011; GB9254-2008; GB17625.1-2012|| |Agency Approvals|Nemko, UL, C-UL, CCC|| |CE mark|Complies with LVD Directive|| ## **6.** |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Operating Temperature7<br>Storage Temperature|-40 to 0°C startup guaranteed, with spec deviation8|-40 to +70°C<br>-40 to 85° C| |Altitude<br>Humidity|Operating:<br>Non-operating:<br>Non-Condensing|16,000 ft.<br>40,000 ft.<br>5% to 95%| |Reliability|MTBF according to Telcordia - SR332-Issue 3|2.56 million hours| ## **7.** |**CONNECTOR**|**PIN**||**DESCRIPTION / CONDITION**|**DESCRIPTION / CONDITION**|**DESCRIPTION / CONDITION**|**DESCRIPTION / CONDITION**|**MANUFACTURER / PN**| |---|---|---|---|---|---|---|---| |AC Input Connector|J1||Pin 1<br>Pin 2<br>Pin 3|||AC Line<br>Not Fitted<br>AC Neutral|Molex: 26-60-4030<br>Mating: 09-50-3031; Pins: 08-50-0106| |DC Output Connector|J2|Screw Terminal<br>(Option 1)|Pin 1<br>Pin 2|||V1 +VE<br>V1 - VE|6-32 inches Screw Pan HD<br>Mating: 16 AWG wire crimped to Ring<br>Tongue Terminal AMP: 8-31886-1| |||Molex Connector|Pin 1,2,3,4|||V1 +VE|Molex: 26-60-4080| |||(Option 2)|Pin 5,6,7,8|||V1 - VE|Mating: 09-50-3081; Pins: 08-50-0106| |Aux (Fan) Output|J3||Pin 1<br>Pin 2|||FAN +VE<br>FAN -VE|AMP :640456-2<br>Mating: 640440-2| |Earth|J4||||||Molex: 19705-4301<br>Mating: 19003-0001| ## **8.** |Weight|300 g| |---|---| |Dimensions|76.2 x 127.0 x 25.4 mm (3 x 5 x 1 inch)| tech.support@psbel.com | ABC350 Series 5 Figure 1. Mechanical Drawing - Screw Terminal (Option 1) Figure 2. Mechanical Drawing - Molex Header (Option 2) - **NOTES:** In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 Stand off, used to mount PCB has OD of 5.4 mm max. - 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. - 3 Washer, if used, to have dia of 6.5 mm max. **==> picture [3 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> ay<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00560_AH ABC350 Series 6 ## **9.** Convection load: 180 W up to 50 °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load: 300 W up to 50°C De-rate above 50 °C @ 2.5% per °C Convection load: 180 W up to 50 °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load: 325 W up to 50°C De-rate above 50 °C @ 2.5% per °C Convection load: 200 W up to 50 °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load: 350 W up to 50°C De-rate above 50 °C @ 2.5% per °C HEBER 5 F@. tech.support@psbel.com 7 ## ABC350 Series E 100 Convection load: 126 W up to 50 °C 3; De-rate above 50 °C @ 2.5% per °C Convection load: 140W up to 50 °C De-rate above 50 °C @ 2.5% per °C **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. **==> picture [48 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> nee Beet<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00560_AH
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →