Image not available
Illustrative purposes only
ABC300-1T30G
OPEN FRAME AC-DC CONVERTERS POWER SUPPLY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: ABC300 Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 143.15 € |
| Current stock | 10+ |
| Lead time | 30 days |
The ABC300 Series of open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 300 W of output power and a variety of single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. - 5 x 3 x 1.5 inch form factor - Key • Features 200 W convection cooled & Benefits - 200 W convection cooled - -20 to 50°C full load operation - No minimum load required - 12 V fan & 5 V standby outputs - Inhibit & Power Good signals - IEC Protection Class Options: - Class I: Earth pin J4 (no suffix) - Class II: No Earth pin (-2 suffix) - Conducted EMI EN 55022-B, FCC Part 15 Level B - ITE Safety Agency Approvals - RoHS Compliant - CE marked - Instrumentation - Lighting - Industrial Applications - • Applied Computing - Renewable Energy - Test and Measurement - Robotics - Wireless Communication ssaes Del kes:POWER ABC300 Series 2 |**MODEL**|**CONNECTOR**|**OUTPUT**<br>**VOLTAGE**|**MAX LOAD**<br>**CONVECTION 1,2,3**|**MAX LOAD**<br>**300 LFM 1,2,3**|**MINIMUM**<br>**LOAD**|**RIPPLE &**<br>**NOISE4**|**TOTAL**<br>**REGULATION**| |---|---|---|---|---|---|---|---| |ABC300-1T05G|Screw Terminal|5 VDC|28.0 A|40.0 A|0.0 A|2%|± 2.5%| |ABC300-1T12G|Screw Terminal|12 VDC|16.67 A|25.0 A|0.0 A|2%|± 2.5%| |ABC300-1T15G|Screw Terminal|15 VDC|13.33 A|20.0 A|0.0 A|2%|± 2.5%| |ABC300-1T24G|Screw Terminal|24 VDC|7.5 A|13.54 A|0.0 A|2%|± 2.5%| |ABC300-1T30G|Screw Terminal|30 VDC|6.0 A|10.83 A|0.0 A|2%|± 2.5%| |ABC300-1T48G|Screw Terminal|48 VDC|3.75 A|6.77 A|0.0 A|2%|± 2.5%| |Cover-300-XCB5|Metal cover kit accessory||||||| Specifications are for nominal input voltage, 25°C unless otherwise stated. |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Input Voltage|Universal|90-264 VAC / 120-390 VDC| |Input Frequency||47 to 63 Hz| |Input Current|120 VAC<br>230 VAC|3.2 A max<br>1.65 A max| |No Load Power||0.8 W| |Inrush Current|120 VAC<br>230 VAC|35 A max<br>65 A max| |Leakage Current|120 VAC<br>230 VAC|< 150μA<br>< 300μA| |Switching Frequency|PFC converter (fixed)<br>Resonant converter (variable)|80 kHz typical<br>35 to 250 kHz, 90 kHz typical| > 1 Peak current rating on main output is 120% of max., lasting < 30 s with a maximum 10% duty cycle. > 2 Combined output power of main output, fan supply and standby supply shall not exceed max. power rating. > 3 Derate output power linearly to 80% from 90 VAC to 80 VAC input. > 4 Ripple is peak to peak with 20 MHz bandwidth and 10 μ F (Tantalum capacitor) in parallel with a 0.1 μ F capacitor at rated line voltage and load ranges. > 5 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. tech.support@psbel.com ABC300 Series 3 |**PARAMETER**<br>**DESCRIPTION / CONDITION**<br>**SPECIFICATION**<br>~~ae~~|**PARAMETER**<br>**DESCRIPTION / CONDITION**<br>**SPECIFICATION**<br>~~ae~~|**PARAMETER**<br>**DESCRIPTION / CONDITION**<br>**SPECIFICATION**<br>~~ae~~| |---|---|---| |Output Power6, 7|Derate linearly to 80% from 90 VAC to 80 VAC input.|200 to 325 W| |Efficiency|120 VAC<br>230 VAC|88% typical<br>92% typical| |Hold Up Time|120 / 230 VAC|10 ms| |Power Factor|120 VAC<br>230 VAC|0.98<br>0.95| |Line Regulation||+/-0.5%| |Load Regulation||+/-2%| |Transient Response|50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/μs,|< 10%, recovery time < 5 ms| |Rise Time||< 100 ms| |Set Point Tolerance8||± 1%| |Voltage Output Adjustment||± 3 %| |Over Voltage Protection|Automatic recovery|110 to 150 %| |Over Current Protection||110 to 150 %| |Short Circuit Protection|Short term, automatic recovery|| |Over Temperature Protection|Automatic Recovery|110° C primary heat sink| |**PARAMETER**|**DESCRIPTION / CONDITION**| |---|---| |Power Good9|TTL signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s| |Remote On/ Off|To turn on PSU short remote pin to ground| |Remote Sense|Compensates for 200 mV cable drop| |Conducted Emissions|EN55032-B, CISPR22-B, FCC PART15-B|Pass| |---|---|---| |Radiated Emissions|EN 55032 A;<br>with external core (King core K5B RC 25x12x15-M in input cable)|Pass<br>Level B| |Input Current Harmonics|EN 61000-3-2|Class D| |Voltage Fluctuation and Flicker|EN 61000-3-3|Pass| |ESD Immunity|EN 61000-4-2|Level 3, Criterion A| |Radiated Field Immunity|EN 61000-4-3|Level 3, Criterion A| |Electrical Fast Transient Immunity|EN 61000-4-4|Level 3, Criterion A| |Surge Immunity|EN 61000-4-5|Level 3, Criterion A| |Conducted Immunity|EN 61000-4-6|Level 3, Criterion A| |Magnetic Field Immunity|EN 61000-4-8|Level 3, Criterion A| |Voltage Dips, Interruptions|EN 61000-4-11|Criterion A & B| 6 Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-30% and needs min. 1% load on main output to be within regulation band. Ripple and noise is less than 10%. 7 The de-rating curves are valid for input voltages of 115VAC to 264 VAC. Below 115 VAC to 90 VAC the convection rating is 180 W max. 8 Standby output voltage tolerance including set point accuracy, line and load regulation is +/-10%. Ripple and noise is less than 5%. 9 Power good signal cannot be used as a current source. Internal pull up resistor from PG signal to 5 V is 10K. It is recommended to use external transistor if intended to source current. **==> picture [205 x 47] intentionally omitted <==** **----- Start of picture text -----**<br> Aes POWER<br>me<br>a2ya bel SOLUTIONSPROTECTION &<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 225 977 +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00285_AE ABC300 Series 4 |**PARAMETER**<br>**DESCRIPTION / CONDITION**<br>Refer to de-rating curves (Fig. 1) to determine output power over<br>~~eee ~~|**PARAMETER**<br>**DESCRIPTION / CONDITION**<br>Refer to de-rating curves (Fig. 1) to determine output power over<br>~~eee ~~|**PARAMETER**<br>**DESCRIPTION / CONDITION**<br>Refer to de-rating curves (Fig. 1) to determine output power over<br>~~eee ~~|**SPECIFICATION**<br>-20 to 70°C<br> ~~eee~~| |---|---|---|---| |Operating Temperature|the entire operating temperature range.||| ||Start-up is guaranteed||-20 to 0°C| |Storage Temperature|||-40 to 85° C| ||Convection:|5 V model<br>12 V, 15 V, 24 V, 30 V & 48 V models|140 W max<br>200 W max| |Cooling||5 V model|200 W max| ||With 300LFM:|12 V and 15 V models|300 W max| |||24 V, 30V and 48 V models|325 W max| |Relative Humidity|Non Condensing||95% Rh| |Altitude|Operating:<br>Non-Operating:||10,000 ft.<br>40,000 ft.| |Reliability|MTBF according to Telcordia –SR332-issue 3||1.77 million hours| |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Isolation Voltage|Input to Output:|4242 VDC min| |Safety Standards|Approved to the latest edition of the following standards:<br>CSA/UL60950-1, EN60950-1 and IEC60950-1|| |Agency Approvals|Nemko, Nemko-CCL|| |CE mark|Complies with LVD Directive|| |**CONNECTOR**<br>**PIN**<br>**DESCRIPTION / CONDITION**<br>AC Input Connector<br>J1<br>Pin 1<br>Pin 2<br>AC LINE<br>AC NEUTRAL<br>~~Tr~~|**CONNECTOR**<br>**PIN**<br>**DESCRIPTION / CONDITION**<br>AC Input Connector<br>J1<br>Pin 1<br>Pin 2<br>AC LINE<br>AC NEUTRAL<br>~~Tr~~|**CONNECTOR**<br>**PIN**<br>**DESCRIPTION / CONDITION**<br>AC Input Connector<br>J1<br>Pin 1<br>Pin 2<br>AC LINE<br>AC NEUTRAL<br>~~Tr~~|**CONNECTOR**<br>**PIN**<br>**DESCRIPTION / CONDITION**<br>AC Input Connector<br>J1<br>Pin 1<br>Pin 2<br>AC LINE<br>AC NEUTRAL<br>~~Tr~~|**MANUFACTURER / PN**<br>Molex: 26-60-4030<br>Mating: 09-50-3031; Pins: 08-50-0106<br>~~eee~~| |---|---|---|---|---| |||||6-32 inches Screw Pan HD| |||||Mating: Designed to accept Ring Tongue Terminal AMP : 8-31886-1,| |DC Output Connector|J2|Pin 1<br>Pin 2|RTN<br>V1|wherein one 16 AWG (max) wire can be crimped.<br>Note: One Ring Tongue Terminal with 16 AWG is recommended for| |||||current up to 11 A only.| |||||Use multiple tongue terminals with wire for more current.| |||Pin 1|REMOTE ON/OFF|| |||Pin 2|RTN|| |||Pin 3|VFAN (+12 V/0.5 A)|| |Signals & Aux Power10|J3|Pin 4<br>Pin 5|-VE REMOTE SENSE<br>VSTBY (+5 V/2 A, +/-5%)|Molex: 22-23-2081<br>Mating: 22-01-2087; Pins: 08-50-0113| |||Pin 6|+VE REMOTE SENSE|| |||Pin 7|RTN|| |||Pin 8|POWER GOOD|| |Earth|J4||Spade Connector<br>(Class I product only)|Molex: 19705-4301<br>Mating: 190030001| |**PARAMETER**|**DESCRIPTION / CONDITION**| |---|---| |Weight|450 g (0.99 lbs)| |Dimensions|127.0 x 76.2 x 38.1 mm (5.0 x 3.0 x 1.5 inch)| 10 PSU is supplied with J3 housing, pin-1 and pin-2 shorted to enable main output without remote on/off feature. tech.support@psbel.com ABC300 Series 5 Convection load: 140 W up to 40 °C De-rate above 40 °C @ 1.67% per °C Forced air cooled load: 200 W up to 40°C De-rate above 40 °C @ 1.67% per °C Convection load: 200 W up to 40 °C De-rate between 40-50 °C @ 1% per °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load: 300 W up to 50°C De-rate above 50 °C @ 2.5% per °C Convection load: 200 W up to 40 °C De-rate between 40-50 °C @ 1% per °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load: 325 W up to 50°C De-rate above 50 °C @ 2.5% per °C Figure 1. Derating Curves **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 225 977 +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00285_AE ABC300 Series 6 Figure 2. Mechanical Drawing **NOTES:** In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: - 1 Stand off, used to mount PCB has OD of 5.4 mm max. - 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. - 3 Washer, if used, to have dia of 6.5 mm max. **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. **==> picture [51 x 25] intentionally omitted <==** **----- Start of picture text -----**<br> EC) sie<br>Bei Os<br>**----- End of picture text -----**<br> tech.support@psbel.com
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →