Image not available
Illustrative purposes only
ABC300-1T24G
OPEN FRAME AC-DC CONVERTERS POWER SUPPLY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: ABC300 Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 140.07 € |
| Current stock | 100+ |
| Lead time | 30 days |
## **WLT300** The ABC300 Series of open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 300 W of output power and a variety of single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. ## **Key Features & Benefits** - 5 x 3 x 1.5 inch form factor - 200 W convection cooled - No minimum load required - 5 V Standby output - 12 V Fan output - Inhibit & Power Good signals - IEC Protection Class Options: - Class I: Earth pin J4 (no suffix) - `o` Class II: No Earth pin (-2 suffix) - IEC / EN / UL 62368-1 Compliant - RoHS Compliant - CE marked ## **Applications** - Instrumentation - Lighting - Industrial Applications - Applied Computing - Renewable Energy - Test and Measurement - Robotics - Wireless Communication ## ssAges . ABC300 Series 2 ## **1. MODEL SELECTION** |**MODEL**|**CONNECTOR**|**OUTPUT**<br>**VOLTAGE**|**MAX LOAD**<br>**CONVECTION**|**MAX LOAD **<br>**300 LFM**|**MINIMUM**<br>**LOAD**|**RIPPLE &**<br>**NOISE 1**|**POWER**| |---|---|---|---|---|---|---|---| |ABC300-1T05G|Screw Terminal|5 VDC|28.0 A|40.0 A|0.0 A|2%|200 W| |ABC300-1T12G|Screw Terminal|12 VDC|16.67 A|25.0 A|0.0 A|2%|300 W| |ABC300-1T15G|Screw Terminal|15 VDC|13.33 A|20.0 A|0.0 A|2%|300 W| |ABC300-1T24G|Screw Terminal|24 VDC|8.33 A|13.54 A|0.0 A|2%|325 W| |ABC300-1T30G|Screw Terminal|30 VDC|6.67 A|10.83 A|0.0 A|2%|325 W| |ABC300-1T48G|Screw Terminal|48 VDC|4.17 A|6.77 A|0.0 A|2%|325 W| |Cover-300-XBC2|Metal cover kit accessory||||||| - 1 Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. - 2 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. ## **2. INPUT SPECIFICATIONS** Specifications are for nominal input voltage, 25°C unless otherwise stated. |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Input Voltage|Universal|90 – 264 VAC / 120 – 390 VDC| |Input Frequency||47 to 63 Hz| |Input Current|120 VAC<br>230 VAC|3.2 A max<br>1.65 A max| |No Load Power||0.8 W| |Inrush Current|120 VAC<br>230 VAC|35 A max<br>65 A max| |Leakage Current|120 VAC<br>230 VAC|< 150μA<br>< 300μA| |Switching Frequency|PFC converter (fixed)<br>Resonant converter (variable)|80 kHz typical<br>35 to 250 kHz, 90 kHz typical| tech.support@psbel.com ABC300 Series 3 ## **3. OUTPUT SPECIFICATIONS** **==> picture [451 x 267] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |PARAMETER|DESCRIPTION / CONDITION|SPECIFICATION| |Output Voltage|[ 3]|12 to 48 V| |Stand-by Output|[4]|5 VDC| |Output Power|[ 5, 6]|Derate linearly to 80% from 90 VAC to 80 VAC input.|200 to 325 W| |120 VAC|88% typical| |Efficiency|230 VAC|92% typical| |Hold Up Time|120 / 230 VAC|10 ms| |120 VAC|0.98| |Power Factor| |230 VAC|0.95| |Line Regulation|± 0.5 %| |Load Regulation|± 2 %| |Transient Response|50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/|μ|s,|< 10 %, recovery time < 5 ms| |Rise Time|< 100 ms| |Set Point Tolerance|± 1 %| |Voltage Output Adjustment|± 3 %| |Over Voltage Protection|Automatic recovery|110 to 150 %| |Over Current Protection|110 to 150 %| |Short Circuit Protection|Short term, automatic recovery| |Over Temperature Protection|Automatic Recovery|110° C primary heat sink| |5 V model|140 W max| |Convection| |12, 15, 24, 30 & 48 V models|200 W max| |Cooling|[ 7]|5 V model|200 W max| |With 300 LFM|12 &15 V models|300 W max| |24, 30 & 48 V models|325 W max| **----- End of picture text -----**<br> - 3 Peak current rating on main output is 120% of max., lasting < 30 s with a maximum 10% duty cycle. > 4 Standby output voltage tolerance including set point accuracy, line and load regulation is +/-10%. Ripple and noise is less than 5%. > 5 Combined output power of main output, fan supply and standby supply shall not exceed max. power rating. > 6 Derate output power linearly to 80% from 90 VAC to 80 VAC input. 7 - Refer de-rating curves to determine output power over the entire operating temperature range ## **4. EMC SPECIFICATIONS** **==> picture [442 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |PARAMETER|DESCRIPTION / CONDITION|SPECIFICATION| |Conducted Emissions|EN 55032-B, CISPR22-B, FCC PART15-B|Pass| |EN 55032 A;|Pass| |Radiated Emissions| |With external core (King core K5B RC 25x12x15-M in input cable)|Level B| |Input Current Harmonics|EN 61000-3-2|Class D| |Voltage Fluctuation and Flicker|EN 61000-3-3|Pass| |ESD Immunity|EN 61000-4-2|Level 3, Criterion A| |Radiated Field Immunity|EN 61000-4-3|Level 3, Criterion A| |Electrical Fast Transient Immunity|EN 61000-4-4|Level 3, Criterion A| |Surge Immunity|EN 61000-4-5|Level 3, Criterion A| |Conducted Immunity|EN 61000-4-6|Level 3, Criterion A| |Magnetic Field Immunity|EN 61000-4-8|Level 3, Criterion A| |Voltage Dips, Interruptions|EN 61000-4-11|Criterion A & B| **----- End of picture text -----**<br> **==> picture [52 x 31] intentionally omitted <==** **----- Start of picture text -----**<br> Oe<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00285_AG ABC300 Series 4 ## **5. SAFETY SPECIFICATIONS** **==> picture [412 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |PARAMETER|DESCRIPTION / CONDITION|SPECIFICATION| |Isolation Voltage|Input to Output:|4000 VAC / VDC| |IEC 62368-1:2014, EN 62368-1:2014; A11, UL 62368-1 and| |Safety Standards|CAN/CSA C22.2 No. 62368-1-14| |Agency Approvals|Nemko, UL| |CE mark|Complies with LVD Directive| **----- End of picture text -----**<br> ## **6. ENVIRONMENTAL SPECIFICATIONS** **==> picture [413 x 82] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |PARAMETER|DESCRIPTION / CONDITION|SPECIFICATION| |Refer to de-rating curves|-20 to 70°C| |Operating Temperature| |-20 to 0°C start-up is guaranteed| |Storage Temperature|-40 to 85° C| |Relative Humidity|Non-Condensing|95% Rh| |Altitude|Operating:|10,000 ft.| |Non-Operating:|40,000 ft.| |Reliability|MTBF according to Telcordia –SR332-issue 3|1.77 million hours| **----- End of picture text -----**<br> ## **7. SIGNALS** **==> picture [414 x 47] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |PARAMETER|DESCRIPTION / CONDITION| |Power Good|[ 8]|TTL signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s| |Remote On/ Off|To turn on PSU short remote pin to ground| |Remote Sense|Compensates for 200 mV drop| **----- End of picture text -----**<br> - 8 Power good signal cannot be used as a current source. Internal pull up resistor from PG signal to 5V is 10K. It is recommended to use external transistor if intended to source current. ## **8. CONNECTOR & PIN DESCRIPTION** **==> picture [490 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |CONNECTOR|PIN|DESCRIPTION / CONDITION|MANUFACTURER / PN| |Pin 1|AC LINE|Molex: 26-60-4030| |AC Input Connector|J1|Pin 2|AC NEUTRAL|Mating: 09-50-3031; Pins: 08-50-0106| |6-32 inches Screw Pan HD| |Mating: Designed to accept Ring Tongue Terminal AMP : 8-31886-1,| |DC Output Connector|J2|Pin 1 Pin 2|RTN V1|wherein one 16 AWG (max) wire can be crimped. Note: One Ring Tongue Terminal with 16 AWG is recommended for| |current up to 11 A only.| |Use multiple tongue terminals with wire for more current.| |Pin 1|REMOTE ON/OFF| |Pin 2|RTN| |Pin 3|VFAN (+12 V/0.5 A)| |Pin 4|-VE REMOTE SENSE|Molex: 22-23-2081| |Signal Connector|J3|[9]|Pin 5|VSTBY (+5 V/2 A, +/-5%)|Mating: 22-01-2087; Pins: 08-50-0113| |Pin 6|+VE REMOTE SENSE| |Pin 7|RTN| |Pin 8|POWER GOOD| |Molex: 19705-4301| |Earth (Spade Connector)|J4|(Class I product only)| |Mating: 190030001| **----- End of picture text -----**<br> - 9 PSU is supplied with J3 housing, pin-1 and pin-2 shorted to enable main output without remote on/off feature. tech.support@psbel.com 5 ## ABC300 Series ## **9. DERATING CURVES** The de-rating curves are valid for input voltages of 115 to 264 VAC. Below 115 VAC to 90 VAC the convection rating is 180 W max. Forced air cooled load: 200 W up to 40°C De-rate above 40 °C @ 1.67% per °C Convection load: 140 W up to 40 °C De-rate above 40 °C @ 1.67% per °C Forced air cooled load: 300 W up to 50°C De-rate above 50 °C @ 2.5% per °C Convection load: 200 W up to 40 °C De-rate between 40-50 °C @ 1% per °C De-rate above 50 °C @ 2.5% per °C Forced air cooled load: 325 W up to 50°C De-rate above 50 °C @ 2.5% per °C Convection load: 200 W up to 40 °C De-rate between 40-50 °C @ 1% per °C De-rate above 50 °C @ 2.5% per °C Figure 1. Derating Curves **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00285_AG ABC300 Series 6 ## **10. MECHANICAL SPECIFICATIONS** |**PARAMETER**|**DESCRIPTION / CONDITION**| |---|---| |Weight|450 g (0.99 lbs)| |Dimensions|127.0 x 76.2 x 38.1 mm (5.0 x 3.0 x 1.5 inch)| Figure 2. Mechanical Drawing **==> picture [52 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> eee@ Stitt<br>**----- End of picture text -----**<br> tech.support@psbel.com ABC300 Series 7 Figure 3. Mechanical Drawing with Cover Kit - **NOTES:** In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: 1 Stand off, used to mount PCB has OD of 5.4 mm max. - 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3 Washer, if used, to have dia of 6.5 mm max. ## **For more information on these products consult: tech.support@psbel.com** **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. **==> picture [17 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> hth<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00285_AG
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →