Image not available
Illustrative purposes only
ABC225-1T24L
OPEN FRAME AC-DC CONVERTERS POWER SUPPLY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: ABC225 Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 109.56 € |
| Current stock | 100+ |
| Lead time | 30 days |
The ABC225 Series of open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 225 W of output power and a variety of single and multiple output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. - Key Features & Benefits - 2 x 4 x 1 Inches Form Factor - 225 W with Forced Air Cooling - Efficiencies up to 94% - -40 to 70 °C Operating Temperature - 12 V Fan Output, Thermal Shut-Down Feature - 3.37 Million Hours, Telcordia - SR332-Issue 3 MTBF - Standby Power <0.5 W - RoHS Compliant - CE Marked - Instrumentation - Lighting - Industrial Applications - • Applied Computing - Renewable Energy - Test and Measurement - Robotics - Wireless Communication sssees Del kes:POWER ABC225 Series 2 |**MODEL NUMBER1**|**DESCRIPTION**|**VOLTAGE**|**VOLTAGE**<br>**MAX. LOAD**<br>**(CONVECTION)**<br>**(112.5 W)**|**(CONVECTION)**<br>**MAX. LOAD**<br>**(CONVECTION)**<br>**(120 W)**|**(CONVECTION)**<br>**MAX. LOAD**<br>**(13 CFM)**|**(CONVECTION)**<br>**MAX. LOAD**<br>**(13 CFM)**|**MAX. LOAD**<br>**MIN. LOAD**|**RIPPLE &**<br>**NOISE2**| |---|---|---|---|---|---|---|---|---| |ABC225-1T12L<br>ABC225-1012L|Screw Terminal<br>Molex Connector|Molex Connector<br>12 V|9.37 A|10.0 A|18.75 A||0.0 A|1%| |ABC225-1T15L<br>ABC225-1015L|Screw Terminal<br>Molex Connector|Molex Connector<br>15 V|7.5 A|8.0 A|15 A||0.0 A|1%| |ABC225-1T24L<br>ABC225-1024L|Screw Terminal<br>Molex Connector|Molex Connector<br>24 V|4.68 A|5.0 A|9.37 A||0.0 A|1%| |ABC225-1T30L<br>ABC225-1030L|Screw Terminal<br>Molex Connector|Molex Connector<br>30 V|3.75 A|4.0 A|7.5 A||0.0 A|1%| |ABC225-1T48L<br>ABC225-1048L|Screw Terminal<br>Molex Connector|Molex Connector<br>48 V|2.34 A|2.5 A|4.68 A||0.0 A|1%| |ABC225-1T58L<br>ABC225-1058L|Screw Terminal<br>Molex Connector|Molex Connector<br>58 V|1.94 A|2.07 A|3.88 A||0.0 A|1%| |COVER-225-XBC3metal cover kit accessory|metal cover kit accessory|||||||| Specifications are for nominal input voltage, 25°C unless otherwise stated. |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Input Voltage|Universal<br>(Derate from 100% at 100 VAC to 90% at 85 VAC)|85-264 VAC / 390 VDC| |Input Frequency||47-63 Hz| |Input Current|115 VAC:<br>230 VAC:|2.2 A max.<br>1.1 A max.| |No Load Power|Typical|< 0.5 W| ||115 VAC:|25 A| |Inrush Current|230 VAC:|45 A| ||264 VAC:|75 A| |Leakage Current|Typical (N.A. For Class II Option)<br>Touch current:|300 µA<br><100 µA| |Power Factor|With Full Load|>0.95| |Switching Frequency|PFC:<br>PWM:|70 to 130 kHz<br>50-80 kHz| > 1 For Class II (without input Earth pin) add suffix -2 (e.g.: ABC225-1012L-2). Ensure non-metallic mounting stud when installing a Class II product. > 2 Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. > 3 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. tech.support@psbel.com ABC225 Series 3 |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Output Power4|With 13 CFM:<br>Convection:|225 W<br>Up to 120 W| ||48 V:|94%| |Efficiency|24 V, 30 V:|93%| ||12 V, 15 V:|92%| |Hold-up Time|225 W:<br>110 W:|10 ms<br>16 ms| |Line Regulation||+/-0.5%| |Load Regulation||+/-0.5%| |Transient Response|25% step load change, at 0.1A/µs slew rate,<br>50% duty cycle, 50 Hz = 4%|Recovery time < 5 ms| |Rise Time|Typical|55 ms| |Set Point Tolerance5||+/-1%| |Output Voltage Adjustment6||+/-3%| |Over Current Protection||>110%| |Over Voltage Protection||110 to 140%| |Short Circuit Protection|Hiccup mode|| |Conducted Emissions|EN55032-B, CISPR22-B, FCC PART15-B|Pass| |---|---|---| |Radiated Emissions|EN 55032 A;<br>with external core (King core K5B RC 25x12x15-M in input cable)|Pass<br>Level B| |Input Current Harmonics|EN 61000-3-2|Class D| |Voltage Fluctuation and Flicker|EN 61000-3-3|Pass| |ESD Immunity|EN 61000-4-2|Level 3, Criterion A| |Radiated Field Immunity|EN 61000-4-3|Level 3, Criterion A| |Electrical Fast Transient Immunity|EN 61000-4-4|Level 3, Criterion A| |Surge Immunity|EN 61000-4-5|Level 3, Criterion A| |Conducted Immunity|EN 61000-4-6|Level 3, Criterion A| |Magnetic Field Immunity|EN 61000-4-8|Level 3, Criterion A| |Voltage Dips, Interruptions|EN 61000-4-11|Criterion A & B| |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Isolation Voltage|Input to Output: (For ITE application)<br>Input to GND: (Not Applicable For Class II Option)|3000 VAC<br>1500 VAC| |Safety Standard(s)|Approved to the latest edition of the following standards:<br>CSA/UL60950-1, EN60950-1 and IEC60950-1; Class1 SELV.|| |Agency Approvals|Nemko, UL, C-UL|| |CE mark|Complies with LVD Directive|| 4 Combined output power of main output, fan supply shall not exceed max. Power rating. 5 Fan supply output voltage tolerance including set point accuracy, line & load regulation is +/-10% and Ripple & noise is less than 10%. 6 Adjustment potentiometer is located on the SMT side of the PCB. **==> picture [205 x 47] intentionally omitted <==** **----- Start of picture text -----**<br> GEER POWER<br>me<br>cSZeya bel SOLUTIONSPROTECTION &<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 225 977 +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00554_AG ABC225 Series 4 |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Operating Temperature7|Start-up is guaranteed, with spec deviation, see Fig. 1|-40 to +70°C<br>-40 to 0°C| |Storage Temperature||-40 to +85°C| |Cooling|With 13 CFM forced air cooling<br>With natural convection cooling at 100 to 264 VAC|225 W<br>Up to 120 W| |Relative Humidity|Noncondensing|5% to 95%| |Altitude|Operating:<br>Nonoperating:|16,000 ft.<br>40,000 ft.| |Reliability|MTBF according to Telcordia -SR332-issue 3:|3.37 million hours| Convection load: 120 W up to 40 °C De-rate between 40-50 °C @ 0.625% per °C De-rate above 50 °C @ 2.33% per °C Forced air cooled load: 225 W up to 50°C De-rate above 50 °C @ 2.5% per °C Figure 1. Derating Curve Figure 2. Efficiency Graph at 115 VAC Figure 3. Efficiency Graph at 230 VAC 7 Output ripple can be more than 10% of the output voltage. **==> picture [205 x 41] intentionally omitted <==** **----- Start of picture text -----**<br> nee POWER<br>LEER yk<br>BY atten bel SOLUTIONS<br>Oo &<br>eee PROTECTION<br>**----- End of picture text -----**<br> tech.support@psbel.com ; 5 ## ABC225 Series |**CONNECTOR**|**PIN**|**DESCRIPTION/CONDITION**|**DESCRIPTION/CONDITION**||**MANUFACTURER / PN**| |---|---|---|---|---|---| |AC Input Connector|J1|Pin 1<br>Pin 2<br>Pin 3|AC Line<br>Not Fitted<br>AC Neutral||Molex: 26-60-4030<br>Mating: 09-50-3031; Pins: 08-50-0106| |DC Output Connector|DC Output Connector<br>J2|Pin 1,2,3<br>Pin 4,5,6|V1 +VE<br>V1 - VE|Screw Terminal (Option 1)<br>Molex Connector (Option 2)|Molex: 39357 Series or equivalent<br>Molex: 26-60-4060<br>Mating: 09-50-3061; Pins: 08-50-0106| |Aux (Fan) Output|J3|Pin 1<br>Pin 2|FAN +VE<br>FAN - VE||AMP :640456-2<br>Mating: 640440-2| |**PARAMETER**|**DESCRIPTION/CONDITION**| |---|---| |Weight|200 g approx.| |Dimensions|50.8 x 101.6 x 25.4 mm (2 x 4 x 1 inch)| |Cooling8|225 W with 13 CFM forced air cooling (refer Mechanical Drawing)<br>Up to 120 W with natural convection cooling (refer Derating Curve)| Figure 4. Mechanical Drawing – Screw Terminal (Option 1) 8 225 W with 13CFM forced air cooling and 120 W with natural convection cooling at 100 to 264 VAC. **==> picture [9 x 19] intentionally omitted <==** **----- Start of picture text -----**<br> Re<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 225 977 +1 408 785 5200 © 2017 Bel Power Solutions & Protection BCD.00554_AG ABC225 Series 6 Figure 5. Mechanical Drawing – Molex Connector (Option 2) **NOTES:** In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: - 1 Stand off, used to mount PCB has OD of 5.4 mm max. - 2 Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. - 3 Washer, if used, to have dia of 6.5 mm max. **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. **==> picture [51 x 22] intentionally omitted <==** **----- Start of picture text -----**<br> ven Bik<br>**----- End of picture text -----**<br> tech.support@psbel.com
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →