Image not available
Illustrative purposes only
ABC201-1005G
OPEN FRAME AC-DC CONVERTERS POWER SUPPLY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: BEL / PARTNER STOCK
- Product type: AC / DC Open Frame Power Supplies
- SVHC: To Be Advised
- Product Range: ABC201 Series
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 101.79 € |
| Current stock | 50+ |
| Lead time | 30 days |
## **WLT200** The ABC201 Series of open-frame power supplies, with its wide universal 90-264 VAC input range and high power density, is available at 200 W of output power and a variety of single output voltages. The high efficiency and high power density of the ABC family ensures minimal power loss in end-use equipment, thereby facilitating higher reliability, easier thermal management and meets regulatory approvals for environmentally-friendly end products. These power supplies are ideal for telecom, datacom, industrial equipment and other applications. - Key • Features 5 x 3 x 1.5 Inch Form Factor & Benefits - 200 W with Forced Air Cooling - High Efficiency > 88% - 12 V Fan Output - 5 V Standby Output - Remote Sense - Output Voltage Adjustability - IEC Protection Class Options: - Class I: Earthing Tab J4 (no suffix) - Class II: No Earthing Tab (-2 suffix) - IEC / EN / UL 62368-1 Compliant - Metal Cover Kit Available (optional accessory) - Instrumentation - Lighting - • Industrial Applications - Renewable Energy - • Test and Measurement • Robotics **==> picture [230 x 40] intentionally omitted <==** **----- Start of picture text -----**<br> EERE POWER<br>wn oe gaat 8<br>@: bel SOLUTIONS &<br>**----- End of picture text -----**<br> 2 • Wireless Communication ## ABC201 Series • Applied Computing |**MODEL 1**|**CONNECTOR**|**OUTPUT**<br>**VOLTAGE**|**MAX LOAD 2**<br>**CONVECTION **<br>**300 LFM**|**MAX LOAD 2**<br>**CONVECTION **<br>**300 LFM**|**MIN LOAD**|**POWER**| |---|---|---|---|---|---|---| |ABC201-1005G<br>ABC201-1T05G|JST (Header)<br>Screw Terminal|5 VDC|16.67 A|26.0 A<br>35.0 A|0.0 A|130 W<br>175 W| |ABC201-1012G|JST (Header)|12 VDC|13.33 A|16.67 A|0.0 A|200 W| |ABC201-1T12G|Screw Terminal|||||| |ABC201-1015G<br>ABC201-1T15G|JST (Header)<br>Screw Terminal|15 VDC|10.67 A|13.33 A|0.0 A|200 W| |ABC201-1024G|JST (Header)|24 VDC|6.67 A|8.33 A|0.0 A|200 W| |ABC201-1T24G|Screw Terminal|||||| |ABC201-1030G<br>ABC201-1T30G|JST (Header)<br>Screw Terminal|30 VDC|5.33 A|6.67 A|0.0 A|200 W| |ABC201-1048G|JST (Header)|48 VDC|3.33 A|4.17 A|0.0 A|200 W| |ABC201-1T48G|Screw Terminal|||||| |COVER-201-XBC3|Metal Cover Kit (accessory)|||||| > 1 Class I products have an Earthing tab. For Class II version (without Earthing tab) add suffix -2 (e.g.: ABC201-1012G-2). > 2 Combined output power from V1, VSTBY and VFAN should not exceed the total output power rating. > 3 When used in Cover Kit, de-rate output power to 70 % under all operating conditions. Specifications are for nominal input voltage, 25°C unless otherwise stated. |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Input Voltage|Universal|90 – 264 VAC / 120 – 390 VDC| |Input Frequency||47 – 63 Hz| |Input Current|120 VAC:<br>230 VAC:|2.4 A max.<br>1.2 A max.| |Inrush Current|120 VAC:<br>230 VAC:|35 A max.<br>65 A max.| |Leakage Current|120 VAC:<br>230 VAC:|< 150 µA<br>< 300 µA| |No Load Power||0.8 W| |Switching Frequency|PFC converter (variable)<br>Resonant converter (variable)|35 to 250 kHz, 90 kHz typical<br>35 to 250 kHz, 90 kHz typical| tech.support@psbel.com 3 ## ABC201 Series |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Output Voltage|Refer to Model Selection table|5 V to 48 V| |Output Power4|Peak Power: 250 W for 2 s|160 to 200 W| |Fan Output5|@ 5 A|12 V| |Efficiency|120 VAC:<br>230 VAC:|84% typical<br>86% typical| |Hold Up Time|120 VAC / 230 VAC:|10 ms| |Power Factor|120 VAC:<br>230 VAC:|0.99<br>0.95| |Line Regulation||± 0.5%| |Load Regulation||± 2.0%| |Transient Response<br>Ripple6|50 to 100% load change, 50 Hz, 50% duty cycle, 0.1A / µs<br>All outputs|< 10%,<br>recovery time < 5 ms<br>1.0 % max| |Rise Time||< 100 ms| |Set Point Accuracy|Main output|± 1%| |Output Voltage Adjustment|V1|± 3 %| |Over Current Protection||110% typical above rating| |Over Voltage Protection|V1|110 to 150%| |Short Circuit Protection|Short term, Automatic recovery|| |Cooling|Convection<br>300 LFM|83 W (5 V model), 160 W (other models)<br>175 W (5 V model), 200 W (other models)| - 4 Derate output power linearly to 80% from 90 VAC to 80 VAC input. - 5 Fan output voltage tolerance is +/-20%. During V1 full load, VFAN needs min. 20 mA load to be within regulation band. Peak current for fan output is 1 A. - 6 Ripple is 2% up to 20% load and < 1% above 20% load. Ripple is peak to peak with 20 MHz bandwidth and 10 µF (Electrolytic capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges. |Conducted Emissions|EN 55032-B, CISPR22-B, FCC PART15-B|Pass| |---|---|---| |Radiated Emissions|EN 55032 B|Pass| |Input Current Harmonics|EN 61000-3-2|Class D| |Voltage Fluctuation and Flicker|EN 61000-3-3|Pass| |ESD Immunity|EN 61000-4-2|Level 3, Criterion A| |Radiated Field Immunity|EN 61000-4-3|Level 3, Criterion A| |Electrical Fast Transient Immunity|EN 61000-4-4|Level 3, Criterion A| |Surge Immunity|EN 61000-4-5|Level 3, Criterion A| |Conducted Immunity|EN 61000-4-6|Level 3, Criterion A| |Magnetic Field Immunity|EN 61000-4-8|Level 3, Criterion A| |Voltage Dips, Interruptions|EN 61000-4-11|Criterion A & B| **==> picture [205 x 44] intentionally omitted <==** **----- Start of picture text -----**<br> sees POWER<br>me<br>. ©ea. bel SOLUTIONSPROTECTION&<br>**----- End of picture text -----**<br> **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00284_AG ABC201 Series 4 |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Isolation Voltage|Input to Output:|Min. 4000 VDC| |Safety Standards|EN / IEC / UL 62368-1 (Ed.3)|| |Agency Approvals|Nemko, UL|| |CE mark|Complies with LVD Directive|| |**PARAMETER**|**DESCRIPTION / CONDITION**|**SPECIFICATION**| |---|---|---| |Operating Temperature7|-20 to 0°C start-up is guaranteed|-20 to 70°C| |Storage Temperature||-40 to 85° C| |Humidity|Non Condensing|95%| |Altitude<br>Reliability|Operating:<br>Non-Operating:<br>MTBF according to Telcordia –SR332-Issue 3|10,000 ft.<br>40,000 ft.<br>1.6 million hours| > 7 Refer to derating curves Convection load: 83 W up to 40 °C De-rate above 40 °C @ 1.89% per °C Forced air cooled load: 130 W up to 50°C (for screw terminal version) De-rate above 50 °C @ 1.63% per °C Forced air cooled load: 175 W up to 50°C (for JST connector version) De-rate above 50 °C @ 2.5% per °C Convection load: 160 W up to 40 °C De-rate above 40 °C @ 2% per °C Forced air cooled load: 200 W up to 50°C De-rate above 50 °C @ 2.5% per °C Figure 1. Derating Curves **==> picture [9 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> i<br>**----- End of picture text -----**<br> tech.support@psbel.com ABC201 Series 5 |**PARAMETER**|**DESCRIPTION / CONDITION**| |---|---| |Power Good Signal|TTL signal goes high after main output is in regulation band. Delay is 0.1 to 0.3 sec.| |Power Fail Signal|TTL signal goes low 1 ms advance before output goes out of regulation due to mains failure| |Remote Sense|Compensates for 200 mV cable drop| |Remote ON / OFF|To turn on PSU short remote pin to ground| |**CONNECTOR**|**PIN**|**PIN**<br>**DESCRIPTION / CONDITION**|**PIN**<br>**DESCRIPTION / CONDITION**|**MANUFACTURER / PN**| |---|---|---|---|---| |AC Input Connector|J1|Pin 1<br>Pin 2<br>AC Neutral<br>AC Line||Molex: 26-60-4030 or equivalent;<br>Mating: 09-50-3031; Pins: 08-50-0106| |DC Output Connector|J2|Pin 1,2,3<br>Pin 4,5,6<br>RTN<br>Vout||Option 1:<br>Tyco: 2-1776112-3 or equivalent<br>Mating: 13 AWG wire<br>Option 2:| |||Pin 1|+VE Remote Sense|JST: B6P-VH-B (LF) (SN) or B6P-VH (LF) (SN) or equivalent<br>Mating: VHR-6M; Pins: SVH-41T-P1.1| |||Pin 2<br>VFAN (+12 V/0.5 A)||| |||Pin 3<br>-VE Remote Sense||| |Signals & Aux Power8|J3|Pin 4<br>Pin 5<br>Remote ON/OFF<br>VSTBY (+5 V/1 A, +/-5%)||Molex: 22-23-2081 or equivalent<br>Mating: 22-01-2087, Pins: 08-50-0113| |||Pin 6<br>RTN (Signal)||| |||Pin 7<br>Power Fail||| |Earth8(Spade Connector)|J4|Pin 8<br>Power Good||Molex: 19705-4301 or equivalent<br>Mating: 190030001| > 8 PSU is supplied with J3 housing, pin-4 and pin-6 shorted to enable main output without remote on/off feature > 9 Class I product only |**PARAMETER**|**DESCRIPTION / CONDITION**| |---|---| |Weight|325 g (0.72 lbs.)| |Dimensions|127.0 x 76.2 x 38.1 mm (5 x 3 x 1.5 in)| **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00284_AG 6 ## ABC201 Series Figure 2. Mechanical Drawing **NOTES:** In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following: Stand off, used to mount PCB has OD of 5.4 mm max. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. Washer, if used, to have dia of 6.5 mm max. tech.support@psbel.com 7 ## ABC201 Series Figure 3. Mechanical Drawing with Cover Kit **NUCLEAR AND MEDICAL APPLICATIONS** - Products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. **TECHNICAL REVISIONS** - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. **Asia-Pacific Europe, Middle East North America** +86 755 298 85888 +353 61 49 8941 +1 866 513 2839 © 2022 Bel Power Solutions & Protection BCD.00284_AG
Updated at April 22, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →