Image not available
Illustrative purposes only
85102435
RELAY, SAFETY, 3NO, SPST-NC, 250VAC, 8A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type: Safety Relays
- ; RELAY, SAFETY, 3NO, SPST-NC, 250VAC, 8A; Product Range:KNE3-YS Series; Contact Configuration:3PST-NO, SPST-NC; Coil Voltage:230VAC; Contact Current:8A; Relay Mounting:DIN Rail; R
- SVHC: No SVHC (17-Dec-2014)
- IP Rating: IP20, IP40
- Coil Voltage: 230VAC
- Product Range: KNE3-YS Series
- Relay Mounting: DIN Rail
- Contact Current: 8A
- Relay Terminals: Screw
- Contact Configuration: 3PST-NO, SPST-NC
- Contact Voltage AC Nom: 250V
- Contact Voltage DC Nom: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 274.92 € |
| Current stock | 10+ |
| Lead time | 30 days |
28/07/2014 www.crouzet.com ## **Emergency stop and safety guard monitoring 2 channels KNE3-YS Part number 85102435** "Emergency stop" & "Safety gates monitoring" functions Single and 2-channel operation Security with redundancy and feedback circuit 3 "NO" security contacts 1 "NC" monitoring contact Security category 4 (according to EN 954-1) Performance Level (PL) e, safety category 4 to EN ISO 13849-1 SIL Claimed Level (SIL CL) 3 to IEC/EN 62061 Terminals : fixed screw terminals or plugin cage clamp terminals |**Part numbers**<br>~~SS~~|**Part numbers**<br>~~SS~~|**Part numbers**<br>~~SS~~|**Part numbers**<br>~~SS~~|**Part numbers**<br>~~SS~~| |---|---|---|---|---| |**Type**<br>**Terminals**<br>**85102435**<br>KNE3-YS<br>Screws<br>SS||**Voltages**<br>230 VAC|**Supply frequency range (Hz)**<br>50/60|**Outputs**<br>3 NO + 1 NC| |**Specifications**<br>~~SS~~||||| |**Operating characteristics**||||| |Functions|Emergency stop|||| ||Safety gates monitoring|||| |Operation<br>Control input<br>ee<br>rrrrrrrr———s|1 or 2 channels<br>Manual restart with On-button (Y1 - Y2 terminals)|||| ||Automatic restart (switch S2 & Y1 - Y2 linked)|||| |Failure detection|Monitored start on On-button|||| ||With or without cross fault monitoring in the emergency-stop loop (switch S1)|||| |Display of output state by LED|Power supply : PWR|||| ||Output : OUT1 (relay K1)|||| ||Output : OUT2 (relay K2)|||| |**Supply**||||| |Supply voltage|85 102 436 / 85 103 436 : 24 V AC/DC||85 102 436 / 85 103 436 : 24 V AC/DC|| ||85 102 434 : 110-115 VAC|||| ||85 102 435 : 230 VAC|||| |Supply frequency range (Hz)<br>rrr|50 / 60|||| |Operating range|AC/DC :± 10 % Un|||| ||AC : -15 % +10 % Un|||| |Consumption|1,5 W (24 VDC)|||| ||3,7 VA (230 VAC)|||| |Initialization time<br>~~ee~~|250 ms|||| |**Precision**||||| |Maximum reset time|30 ms (manual start)|||| ||350 ms (automatic start)|||| |Maximum response time on emergency stop|150 ms (AC/DC)|||| ||50 ms (AC)|||| |**Output specification**||||| |Type<br>Number of safety circuits<br>Perrrrrrrrrr——CO<br>rrr|Forcibly guided relays (positively driven)<br>3 NO|||| |Number of data circuits<br>Nominal output voltage<br>Perrrrrrrrrr———CO<br>~~a~~|1 NC<br>250 V AC max.|||| |Max. thermal current I for each contact<br>~~a~~|8 A|||| |Maximum power rating|According to AC15 (NO contacts) : 3 A / 230 V AC|||| ||According to AC15 (NC contacts) : 2 A / 230 VAC|||| ||According to DC13 (NO contacts) : 4 A / 24 VDC ; 0,5 A / 110 VDC|||| ||According to DC13 (NC contacts) : 4 A / 24 VDC|||| |Electrical endurance|At 5 A, 230 VAC, cosφ=1 : 1,5 x 105switching cycles|||| |Mechanical life<br>Maximum rate<br>Protection against short circuits<br>TT<br>TTTTTOCOCO™O.CC‘*S<br>ee<br>rrrrrrrs—s|At 8 A, 24 VDC, according to DC 13 (NO contacts) : 25 x 103switching cycles (ON : 0,4 s ; OFF : 9,6 s)<br>20 x 106switching cycles<br>1200 switching cycles / h<br>Max. fuse rating : 10 A gL|||| ||Line circuit breaker : B 6 A|||| |**Climatic environment**||||| |Operating temperature (oC)<br>Storage temperature (0C)<br>Altitude<br>~~a~~<br>TT<br>TTTOOCOC™~™O.C*W<br>res|-15 →+55<br>-25 →+85<br>< 2000 m|||| |Climate resistance according to IEC/EN 60068-1<br>~~ee~~|15 / 055 / 04|||| |**Mechanical environment**||||| Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected www.crouzet.com 28/07/2014 Vibration resistance according to IEC/EN 60068-2-6 Amplitude : 0,35 mm Lo Frequency : 10 →55 Hz **Electromagnetic environment** Immunity to electrostatic discharges acc. IEC/EN 61000-4- ~~Lo~~ 2 8 kV (air) Immunity to radiated, radio-frequency, electromagnetic 10 V / m Lo field acc. IEC/EN 61000-4-3 Immunity to rapid transient bursts acc. to IEC/EN 61000-42 kV Lo 4 Immunity to shock waves according to IEC/EN 61000-4-5 Between wires for power supply : 1 kV (AC), 0,5 kV (24 V AC/DC) Lo Between wires and ground : 2 kV Immunity to radio frequency in common mode acc. to 10 V Lo IEC/EN 61000-4-6 ~~ee~~ Interference suppression according to IEC/EN 55011 Limit value class B **Housing** O————C—C“‘CC*rs Material : self-extinguishing (UL94VO) Thermoplastic with V0 extinction behaviour P————C‘CCC*rs Protection (IEC/EN 60529) - Casing IP40 P—————C‘CC*zr Protection (IEC/EN 60529) - Term. block IP20 Prrr——C—CiC‘C*zS Mounting DIN-rail Weight (g) 210 (24 VAC/DC) ~~Lo~~ 275 (230 VAC) **Safety standards** PO——C‘CSCi*zCS Approvals CE, TÜV, UL / CSA PO——Ci‘CSCtsC*d Environmental directive 2002/95/CE RoHS PO——C“‘CO;OCC*d Environmental regulation 1907/2006 Reach Security data according to EN ISO 13849-1 Performance Level (PL) : e ~~Lo~~ Category : 4 PO——Ci‘CSCtsC*d SIL Claimed Level (SIL CL) to IEC/EN 62061 3 PO——C“(‘CO;COC‘*dr Safety Integrity Level (SIL) according to CEI/EN 61508 3 ~~ee~~ Safety category to EN 954-1 4 ~~ee~~ **Principles** Enisoveer; ida [Categoy: | [| Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 28/07/2014 www.crouzet.com ~~e~~ **Dimensions (mm)** ~~er~~ ~~rrr~~ **Dimensions (mm) KNE3-YS - Screw terminals** ## ~~ee~~ **Curves Function diagram** ~~eer~~ **Connections Front face drawing KNE3-YS** Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 28/07/2014 www.crouzet.com ~~ee~~ **Connections Contacts** A1 (+) : + / L A2 : - / N Y1, Y2 : Validation Input Y11, Y21, Y12, Y22 : Control Inputs 13, 14, 23, 24, 33, 34 : Safety circuit outputs (forcibly guided NO contacts) 41, 42 : Monitoring output (forcibly Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 28/07/2014 guided NC contact) www.crouzet.com ~~ee~~ **Applications Single channel emergency stop circuit** This circuit does not have any redundancy in the emergency-stop control circuit. S1 : no cross fault detection S2 : automatic start ~~ee~~ **Applications 2-channel emergency stop circuit without cross fault monitoring** S1 : no cross fault detection S2 : manual start ~~ee~~ **Applications Contact reinforcement by external contactors controlled by one contact path** Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 28/07/2014 www.crouzet.com S1 : no cross fault detection S2 : automatic start ~~ee~~ **Applications 2-channel safety gate monitoring** S1 : no cross fault detection S2 : manual start ~~|~~ **Applications Contact reinforcement by external contactors, 2-channel controlled** Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 28/07/2014 www.crouzet.com For currents > 8 A, the output contacts can be reinforced by external contactors. Functioning of the external contactors is monitored by looping the NC contacts into the start circuit (Y1-Y2) ~~a~~ **Applications 2-channel emergency stop circuit with cross fault monitoring** S1 : cross fault detection S2 : manual start Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →