Image not available
Illustrative purposes only
80.41.0.240.0000
Time Delay Relay, 100 ms, 24 h, 80 Series, SPDT, 16 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Time Delay Relays - Electromechanical
- Product Range:80 Series; Timer Functions:Off-Delay; Time Min:0.1s; Time Max:24h; No. of Timing Ranges:6Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:240V; Current Ra
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 24h
- Time Min: 100ms
- Product Range: 80 Series
- Relay Mounting: DIN Rail
- Contact Current: 16A
- Relay Terminals: Screw
- Timer Functions: Off-Delay
- Nom Input Voltage: 240VAC
- Timing Adjustment: Screwdriver Slot
- Contact Voltage VAC: 250V
- Contact Voltage VDC: -
- Contact Configuration: SPDT
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 43.58 € |
| Current stock | 50+ |
| Lead time | 30 days |
Modular timers 1 - 6 - 8 - 16 A Building automation Elevators and lifts Automation for blinds, grilles and shutters Hoists and cranes Panels for electrical distribution Door and gate openers **80 SЕRIES** FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products. **80 SERIES** **Multi-function and mono-function timer range** **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 80.01<br>**----- End of picture text -----**<br> **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 80.11<br>**----- End of picture text -----**<br> ## **80.01 - Multi-function & multi-voltage** ## **80.11 - On-delay, multi-voltage** - 17.5 mm wide - Six time scales from 0.1 s to 24 h - High input/output isolation - 35 mm rail (EN 60715) mount - “Blade + cross” - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip - New multi-voltage versions with “PWM clever” technology 80.01 / 80.11 Screw terminal - Multi-voltage - Multi-function **AI:** On-delay **DI:** Interval **SW:** Symmetrical flasher (starting pulse on) - Multi-voltage - Mono-function **AI:** On-delay **BE:** Off-delay with control signal **CE:** On- and off-delay with control signal **DE:** Interval with control signal on ## _For UL ratings see:_ ## _“General technical information” page_ V Wiring diagram Wiring diagram Wiring diagram For outline drawing see page 9 (without control signal) (with control signal) (without ~~c~~ ontrol signal) **Contact specification** Contact configuration 1 CO (SPDT) 1 CO (SPDT) Rated current/Maximum peak current A ~~a~~ 16/30 16/30 Rated voltage/ Maximum switching voltage V AC 250/400 250/400 Rated load AC1 VA 4000 4000 ~~a~~ Rated load AC15 (230 V AC) VA 750 750 ~~a~~ Single phase motor rating (230 V AC) kW ~~a~~ 0.55 ~~0.~~ 55 Breaking capacity DC1: 30/110/220 V A ~~a~~ 16/0.3/0.12 16/0.3/0.12 Minimum switching load mW (V/mA) 500 (10/5) 500 (10/5) ~~a~~ Standard contact material AgNi AgNi **Supply specification** Nominal voltage (UN) V AC (50/60 Hz) 12…240 24…240 V DC 1 ~~2~~ …240 24…240 ~~a~~ Rated power AC/DC VA (50 Hz)/W ~~a~~ < 1.8/< 1 < 1.8/< 1 Operating range V AC 10.8…265 16.8…265 V DC 10.8…265 16.8…265 **Technical data** Specified time range (0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h Repeatability % ~~a~~ ± 1 ± 1 Recovery time ms ~~a~~ 100 100 Minimum control impulse ms ~~a~~ 50 — Setting accuracy-full range % ~~a~~ ± 5 ± 5 Electrical life at rated load in AC1 cycles ~~a~~ 50 · 10[3] 50 · 10[3] Ambient temperature range °C ~~a~~ –10…+50 –10…+50 Protection category ~~a~~ IP 20 IP 20 **Approvals** (according to type) C€ fal RINA ‘@s **H** **3** **80 SERIES** ## **Mono-function timer range** ## **80.21** **==> picture [25 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 80.41<br>**----- End of picture text -----**<br> **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 80.91<br>**----- End of picture text -----**<br> ## **80.21 - Interval, multi-voltage** ## **80.41 - Off-delay with control signal, multi-voltage 80.91 - Asymmetrical flasher, multi-voltage** - 17.5 mm wide - Six time scales from 0.1 s to 24 h - High input/output isolation - 35 mm rail (EN 60715) mount - “Blade + cross” - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip - New multi-voltage versions with “PWM clever” technology - Multi-volta ~~ge~~ - Mono-function **DI:** Interval - Multi-volta ~~ge~~ - Mono-function **BE:** Off-delay with control signal - Multi-voltage - Mono-function **LI:** Asymmetrical flasher (starting pulse on) 80.21 / 80.41 / 80.91 Screw terminal **LE:** Asy ~~m~~ metrical flasher (starting pulse on) with control signal ## _For UL ratings see:_ _“General technical information” page_ V ||_“General technical information” pageGeneral technical information” page” pagepage_|_“General technical information” pageGeneral technical information” page” pagepage_V||||||~~Wir~~ing diagram<br>~~Wir~~ing diagram|| |---|---|---|---|---|---|---|---|---|---| ||||Wiring diagram|Wiring diagram||||(without control<br>(with control|| ||For outline drawing see page 9||(without control signal)|(with control signal)||(with control signal)||signal)<br>signal)|| ||**Contact specification**<br>Contact configuration||1 CO (SPDT)|1 CO (SPDT)||||1 CO (SPDT)|| |**H**|Rated current/Maximum peak current<br>A<br>Rated voltage/<br>Maximum switchingvoltage<br>V AC||16/30<br>250/400||16/30<br>250/~~4~~00|||16/30<br>250/400|| ||Rated load AC1|VA|4000|||4000||4000|| ||Rated load AC15 (230 V AC)|VA|750||||750|750|| ||Single phase motor rating (230 V AC)<br>kW||0.55|||0.55||0.55|| ||Breaking capacity DC1: 30/110/220 V<br>A||16/0.3/0.12|16/0.3/0.12||||16/0.3/0.12|| ||Minimum switching load|mW (V/mA)|500 (10/5)|500 (10/5)||||500 (10/5)|| ||Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)|V AC (50/60 Hz)|AgNi<br>24…240||AgNi<br>24…240|||AgNi<br>12…240|| |||V DC|24…240||24…240|||12…240|| ||Rated power AC/DC|VA (50 Hz)/W|< 1.8/< 1||< 1.8/< 1|||< 1.8/< 1|| ||Operating range|V AC|16.8…265|16.8…265||||10.8…265|| ||**Technical data**|V DC|16.8…265|16.8…265||||10.8…265|| ||Specified time range||(0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h||||||| ||Repeatability|%|± 1||||± 1|± 1|| ||Recovery time|ms|100||||100|100|| ||Minimum control impulse|ms|—||||50|50|| ||Setting accuracy-full range<br>Electrical life at rated load in AC1<br>Ambient temperature range<br>Protection category<br>**Approvals**(according to type)|%<br>cycles<br>°C|± 5<br>50 · 103<br>–10…+50<br>IP 20<br>~~C€~~|± 5<br>50 · 103<br>–10…+50<br>IP 20<br>~~C€FAL~~<br>~~BRINA-@e~~||||± 5<br>50 · 103<br>–10…+50<br>IP 20<br>~~-@e~~|III-2018, www.findernet.com| **4** **80 SERIES** **H** ## **Multi-function and multi-voltage solid-state output timer** **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 80.71<br>**----- End of picture text -----**<br> - 17.5 mm wide - Six time scales from 0.1 s to 24 h - High input/output isola ~~t~~ ion - 35 mm rail (EN 60715) mount - Multi-voltage output (24…240 V AC/DC), independent from the input voltage - “Blade + cross” - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip - Multi-voltage input with “PWM clever” technology • Multi-voltage - Multi-function **AI:** On-delay **DI:** Interval 80.71 ## Screw terminal **SW:** Symmetrical flasher (starting pulse on) **BE:** Off-delay with control signal **CE:** On- and off-delay with control signal **DE:** Interval with control signal on ||||Wiring diagram<br>Wiring diagram| |---|---|---|---| ||For outline drawing see page 9||(without control signal)<br>(with control signal)| ||**Output circuit**<br>Contact configuration||1 NO (SPST-NO)| ||Rated current|A|1<br>~~a~~| ||Rated voltage|V AC/DC|24…240<br>~~a~~| ||Switching voltage range|V AC/DC|19…265<br>~~a~~| ||Rated load AC15|A|1<br>~~a~~| ||Rated load DC1|A|1<br>~~a~~| ||Minimum switching current|mA|0.5<br>~~a~~| ||Max. “OFF-state” leakage current|mA|0.05<br>~~a~~| ||Max. “ON-state” voltage drop<br>**Input circuit**<br>Nominal voltage (UN)<br>Rated power|V<br>V AC (50/60 Hz)<br>V DC<br>VA (50 Hz)/W|2.8<br>24…240<br>24…240<br>1.3/1.3<br>~~**a**~~| ||Operating range<br>**Technical data**|V AC<br>V DC|19…265<br>19…265<br>~~a~~| ||Specified time range||(0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h| ||Repeatability<br>Recovery time<br>Minimum control impulse|%<br>ms<br>ms|± 1<br>100<br>50<br>~~a~~<br>~~a~~| |III-2018, www.findernet.com|Setting accuracy-full range<br>Electrical life<br>Ambient temperature range<br>Protection category<br>**Approvals**(according to type)|%<br>cycles<br>°C|± 5<br>100 · 106<br>–20…+50<br>IP 20<br>~~a~~<br>~~a~~<br>~~a~~<br>~~co~~<br>~~C€FAL~~<br>~~BIRINA~~| **5** **80 SERIES** ## **Mono-function timer range** **==> picture [25 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 80.61<br>**----- End of picture text -----**<br> **==> picture [25 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 80.82<br>**----- End of picture text -----**<br> ## **80.61 - Power off-delay (True off-delay), multi-voltage** ## **80.82 - Star-delta, multi-voltage** - 17.5 mm wide - Rotary range selector, and timing trimmer - Four time scales from 0.05s to 180 s (type 80.61) - Six time scales from 0.1 s to 20min (type 80.82) - High input/output isolation - 35 mm rail (EN 60715) mount ## 80.61 / 80.82 Screw terminal - Multi-voltage - Mono-function - M ~~u~~ lti-voltage - Mono-function • Transfer time can be regulated (0.05…1)s **BI:** Power off-delay (True off-delay) **SD:** Star-delta ## _For UL ratings see:_ _“General technical information” page_ V |||Wiring diagram<br>Wiring diagram|| |---|---|---|---| ||For outline drawing see page 9|(without control signal)<br>(~~wi~~thout control signal)|| |**H**|**Contact specification**<br>Contact configuration<br>1 CO (SPDT)<br>2 NO (DPST-NO)<br>Rated current/Maximum peak current<br>A<br>8/15<br>6/10<br>Rated voltage/<br>Maximum switchingvoltage<br>V AC<br>2~~5~~0/400<br>250/400<br>~~rs~~<br>~~rr~~||| ||Rated load AC1|VA<br>2000<br>1500<br>~~es~~|| ||Rated load AC15 (230 V AC)|VA<br>400<br>300<br>~~es~~|| ||Single phase motor rating (230 V AC)<br>kW<br>0.3<br>—<br>~~es~~||| ||Breaking capacity DC1: 30/110/220 V<br>A<br>8/0.3/0.12<br>6/0.2/0.12<br>~~es~~||| ||Minimum switching load|mW (V/mA)<br>300 (5/5)<br>500 (12/10)<br>~~ee~~|| ||Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)|AgNi<br>AgNi<br>V AC (50/60 Hz)<br>24…240<br>24…240|| |||V DC<br>24…220<br>24…240<br>~~es~~|| ||Rated power AC/DC<br>Operating range<br>**Technical data**|VA (50 Hz)/W<br>< 0.6/< 0.6<br>< 1.3/< 0.8<br>V AC<br>16.8…265<br>16.8…265<br>V DC<br>16.8…242<br>16.8…265<br>~~ee~~<br>~~es~~|| ||Specified time range|(0.05…2)s, (1…16)s, (8…70)s, (50…180)s<br>(0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min|| ||Repeatability|%<br>± 1<br>± 1<br>~~es~~|| ||Recovery time|ms<br>—<br>100<br>~~es~~|| ||Minimum control impulse|ms<br>500 (A1-A2)<br>—<br>~~ee~~|| ||Setting accuracy-full range<br>Electrical life at rated load in AC1<br>Ambient temperature range<br>Protection category<br>**Approvals**(according to type)|%<br>± 5<br>± 5<br>cycles<br>100 · 103<br>60 · 103<br>°C<br>–10…+50<br>–10…+50<br>IP 20<br>IP 20<br>~~ee~~<br>~~es~~<br>~~es~~<br>~~RR~~<br>Cé€ EA<br>RINA @«|III-2018, www.findernet.com| **6** **80 SERIES** **H** ## **Multi-function and multi-voltage** **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 80.51<br>**----- End of picture text -----**<br> - 17.5 mm wide - Six time scales from 0.1 s to 24 h - High input/output isolation - 35 mm rail (EN 60715) mount - “Blade + cross” - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip - New multi-voltage versions with “PWM clever” technology 80.51.0.240.0000 80.51..0.240.P000 Screw terminal Push-in terminal - Multi-voltage (24…240) V AC/DC - Multi-function **AI:** On-delay **DI:** Interval **SW:** Symmetrical flasher (starting pulse on) **BE:** Off-delay with control signal **CE:** On- and off-delay with control signal **DE:** Interval with control signal on ## _For UL ratings see:_ _“General technical information” page_ V Wiring diagram Wiring diagram |||Wiring diagram<br>Wiring diagram| |---|---|---| ||For outline drawing see page 9|(without control signal)<br>(with control signal)| ||**Contact specification**<br>Contact configuration|1 CO (SPDT)| ||Rated current/Maximum peak current<br>A<br>8/16<br>Rated voltage/<br>Maximum switchingvoltage<br>V AC<br>250/400<br>~~a~~|| ||Rated load AC1|VA<br>2000<br>~~a~~| ||Rated load AC15 (230 V AC)|VA<br>400<br>~~a~~| ||Single phase motor rating (230 V AC)<br>kW<br>0.3<br>~~a~~|| ||Breaking capacity DC1: 30/110/220 V<br>A<br>8/0.3/0.12<br>~~a~~|| ||Minimum switching load|mW (V/mA)<br>500 (10/5)<br>~~a~~| ||Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)<br>Rated power AC/DC<br>Operating range<br>**Technical data**|AgNi<br>V AC (50/60 Hz)<br>24…240<br>V DC<br>24…240<br>VA (50 Hz)/W<br>< 1.8/< 1<br>V AC<br>17…265<br>V DC<br>17…265<br>~~**a**~~<br>~~a~~| ||Specified time range|(0.1…2)s, (1…20)s, (0.1…2)min, (1…20)min, (0.1…2)h, (1…24)h| ||Repeatability|%<br>± 1<br>~~a~~| ||Recovery time|ms<br>≤ 50<br>~~a~~| ||Minimum control impulse|ms<br>50<br>~~a~~| |III-2018, www.findernet.com|Setting accuracy-full range<br>Electrical life at rated load in AC1<br>Ambient temperature range<br>Protection category<br>**Approvals**(according to type)|%<br>± 5<br>cycles<br>100 · 103<br>°C<br>–10…+50<br>IP 20<br>~~a~~<br>~~a~~<br>~~a~~<br>~~a~~<br>C€<br>FAL @«| **7** **80 SERIES** ## **Ordering information** Example: 80 series, modular timers, 1 CO (SPDT) - 16 A, supply rated at (12…240)V AC/DC. **8 0 . 0 1 . 0 . 2 4 0 . 0 0 0 0** ## **Series** ## **Type** - 0 = Multi-function (AI, DI, SW, BE, CE, DE) - 1 = On-delay (AI) - 2 = Interval (DI) - 4 = Off-delay with control signal (BE) - 5 = Multi-function (AI, DI, SW, BE, CE, DE) - 6 = Power off-delay (True off-delay) (BI) - 7 = Multi-function with solid state output - (AI, DI, SW, BE, CE, DE) - 8 = Star-delta (SD) - 9 = Asymmetrical flasher (LI, LE) - **Versions** 0 = Standard P = Push-in (only for 80.51) **Supply voltage** 240 = (12…240)V AC/DC (80.01, 80.91) 240 = (24…240)V AC/DC - (80.11, 80.21, 80.41, 80.51, 80.71, 80.82) - 240 = (24…240)V AC, (24…220)V DC (80.61) **Supply version** 0 = AC (50/60 Hz)/DC **No. of poles** 1 = 1 CO (SPDT) 1 = 1 NO (SPST-NO), type 80.71 only 2 = 2 NO (DPST-NO), type 80.82 only ## **Technical data** ## **Insulation** **H** |**Technical data**<br>**Insulation**|**Technical data**<br>**Insulation**|||||||| |---|---|---|---|---|---|---|---|---| |Dielectric strength||between input and output circuit||V AC|**80.01/11/21/41/51/82/91**||**80.61**|**80.71**| ||||||4000||2500|2500| |||between open c|ontacts|V AC|1000||1000|—| |Insulation (1.2/50 µs) between input and output||||kV|6||4|4| |**EMC specifications**||||||||| |**Type of test**|||||**Reference standard**|**80.01/11/21/41/61/71/91**||**80.51/82**| |Electrostatic discharge|||contact discharge||EN 61000-4-2|4 kV||4 kV| ||||air discharge||EN 61000-4-2|8 kV||8 kV| |Radio-frequencyelectromagnetic field(80 ÷ 1000 MHz)|||||EN 61000-4-3|10 V/m||10 V/m| |Fast transients(burst) (5-50 ns,5 kHz)on Supplyterminals|||||EN 61000-4-4|4 kV||4 kV| |Surges|(1.2/50 µs) on Supply terminals<br>on start terminal (B1)||common mode||EN 61000-4-5|4 kV||4 kV| ||||differential mode||EN 61000-4-5|4 kV||4 kV| ||||common mode||EN 61000-4-5|4 kV||4 kV| ||||differential mode||EN 61000-4-5|4 kV||4 kV| |Radio-frequencycommon mode(0.15 ÷ 80 MHz)o|||n Supplyterminals||EN 61000-4-6|10 V||10 V| |Radiated and conducted emission|||||EN 55022|class B||class A| |**Other data**||||||||| |Current absorption on signal control(B1)|||||< 1 mA|||| |Power lost to the environment|||without contact curr|ent W|1.4|||| ||||with rated current|W|3.2|||| |**Terminals**|||||**Screw terminals**||**Push-in terminals**|| |Wire striplength||||mm|10||10|| |Screw torque||||Nm|0.8||—|| |Min. wire size||||mm2|solid cable||solid cable|| ||||||0.5||0.75|| |||||AWG|20||18|| |Max. wire size||||mm2|solid cable||solid cable|| ||||||1 x 6 / 2 x 4||1 x 1.5 / 2 x 1.5|| |||||AWG|1 x 10 / 2 x 12||1 x 16 / 2 x 16|| |Min. wire size||||mm2|stranded cable||stranded cable|| ||||||0.5||0.75|| |||||AWG|20||18|| |Max. wire size||||mm2|stranded cable||stranded cable|| ||||||1 x 4 / 2 x 2.5||1 x 2.5 / 2 x 2.5|| |||||AWG|1 x 12 / 2 x 14||1 x 14 / 2 x 14|| **8** **80 SERIES** **H** ## **Outline drawings** 80.01/80.51 Screw terminal **==> picture [39 x 39] intentionally omitted <==** **==> picture [53 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> 80.11/80.21/80.61<br>Screw terminal<br>**----- End of picture text -----**<br> **==> picture [39 x 40] intentionally omitted <==** 80.91 Screw terminal **==> picture [39 x 39] intentionally omitted <==** **==> picture [35 x 92] intentionally omitted <==** **==> picture [34 x 92] intentionally omitted <==** **==> picture [34 x 92] intentionally omitted <==** **==> picture [17 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 80.51<br>**----- End of picture text -----**<br> **==> picture [49 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Push-in terminal<br>**----- End of picture text -----**<br> **==> picture [39 x 39] intentionally omitted <==** **==> picture [161 x 140] intentionally omitted <==** **----- Start of picture text -----**<br> 17.5 4.3 56.5<br>80.41<br>Screw terminal<br>89.8 33.8 45 86<br>30.5<br>**----- End of picture text -----**<br> **==> picture [40 x 40] intentionally omitted <==** **==> picture [35 x 92] intentionally omitted <==** **==> picture [44 x 15] intentionally omitted <==** **----- Start of picture text -----**<br> 80.71<br>Screw terminal<br>**----- End of picture text -----**<br> **==> picture [39 x 39] intentionally omitted <==** **==> picture [35 x 92] intentionally omitted <==** **==> picture [17 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 80.82<br>**----- End of picture text -----**<br> **==> picture [45 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Screw terminal<br>**----- End of picture text -----**<br> **==> picture [55 x 144] intentionally omitted <==** **==> picture [43 x 97] intentionally omitted <==** **9** **80 SERIES** ## **Functions** ||LED*|Supply voltage|NO output<br>contact|Contacts|Contacts| |---|---|---|---|---|---| |||||Open|Closed| |||OFF|Open|15 - 18|15 - 16| ||||||| |||ON|Open|15 - 18|15 - 16| ||||||| |||ON|Open<br>(Timingin Progress)|15 - 18|15 - 16| ||||||| |||ON|Closed|15 - 16|15 - 18| ||||||| - The LED on type 80.61 is illuminated only when the supply voltage is applied to the timer; during the timing period the LED is not illuminated. Without control signal = Start via contact in supply line (A1). **H** ## **Wiring diagram** With control signal = Start via contact into control terminal (B1). **==> picture [513 x 369] intentionally omitted <==** **----- Start of picture text -----**<br> Without control signal Type (AI) On-delay.<br>80.01 Apply power to timer. Output contacts transfer after preset<br>80.51 time has elapsed. Reset occurs when power is removed.<br>80.71<br>(DI) Interval.<br>80.01 Apply power to timer. Output contacts transfer immediately.<br>80.51 After the preset time has elapsed, contacts reset.<br>(SW) Symmetrical flasher (starting pulse on).<br>Apply power to timer. Output contacts transfer immediately<br>and cycle between ON and OFF for as long as power is applied.<br>The ratio is 1:1 (time on = time off).<br>80.71<br>With control signal 80.01 (BE) Off-delay with control signal.<br>80.51 Power is permanently applied to the timer. The output<br>80.71 contacts transfer immediately on closure of the Signal Switch<br>(S). Opening the Signal Switch initiates the preset delay, after<br>which time the output contacts reset.<br>80.01 (CE) On- and off-delay with control signal.<br>80.51 Power is permanently applied to the timer. Closing the Signal<br>Switch (S) initiates the preset delay, after which time the output<br>contacts transfer. Opening the Signal switch initiates the same<br>preset delay, after which time the output contacts reset.<br>(DE) Interval with control signal on.<br>Power is permanently applied to the timer.<br>On momentary or maintained closure of Signal Switch (S), the<br>80.71 output contacts transfer, and remain so for the duration of the<br>preset delay, after which they reset.<br>**----- End of picture text -----**<br> NOTE: The function must be set before energising the timer. **==> picture [67 x 66] intentionally omitted <==** - Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1. - With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1). - ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 230 V AC - B1 - A2 = 12 V DC **10** **80 SERIES** ## **Functions** ## **Wiring diagram** |Without control<br> 80.11/21/61<br>8~~0~~.82|signal<br>**Type**<br>**80.11**<br>**80.21**<br>**80.61**<br>**80.82**|**(AI) On-delay.**<br>Apply power to timer. Output contacts transfer after preset<br>time has elapsed. Reset occurs when power is removed.<br>**(DI) Interval.**<br>Apply power to timer. Output contacts transfer immediately.<br>After the preset time has elapsed, contacts reset.<br>**(BI) Power off-delay (True off-delay).**<br>Apply power to timer (minimum 500 ms). Output contacts<br>transfer immediately. Removal of power initiates the preset<br>delay, after which time the output contacts reset.<br>**(SD)Star-delta.**<br>Apply power to timer. The star contact (<br> ) closes immediately.<br>After preset delay has elapsed the star contact (<br> ) resets.<br>After a further transfer time variable from (0.05…1)s the delta<br>contact (∆) closes and remains in that position, until reset on<br>power off.| |---|---|---| |Withcontrol sign<br>80.41|al<br>**80.41**|**(BE) Off-delay with control signal.**<br>Power is permanently applied to the timer.<br>The output contacts transfer immediately on closure of the<br>Signal Switch (S). Opening the Signal Switch initiates the preset<br>delay, after which time the output contacts reset.| |Without control<br>80.91<br>With co~~nt~~rol sign<br>80.91|signal<br>al<br>**80.91**|**(LI)Asymmetrical flasher (starting pulse on).**<br>Apply power to timer. Output contacts transfer immediately<br>and cycle between ON and OFF for as long as power is applied.<br>The ON (T1) and OFF (T2) times are independently adjustable.<br>**(LE)Asymmetrical flasher (starting pulse on) with control**<br>**signal**<br>Power is permanently applied to the timer.<br>Closing Signal Switch (S) causes the output contacts to transfer<br>immediately and cycle between ON (T1) and OFF (T2), until<br>opened.| ||• Possible to control an external load, such as another relay coil or timer, connected to thecontrol signalterminal B1.<br>* With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1).|| - ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 230 V AC B1 - A2 = 12 V DC **11** **80 SERIES** **H** ## **Accessories** **Sheet of marker tags** , for types 80.82, plastic, 24 tags, 9 x 17 mm 020.24 **020.24** (So **Sheet of marker tags (CEMBRE Thermal transfer printers)** for relays types &&&& 060.48 ttt-t +t&t 80.01/11/21/41/51/61/71 (48 tags), 6 x 12 mm 5= Ee = Ie=} **060.48** Please see general technical information **12**
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →