- Manufacturer: FINDER
- Product type: Safety Relays
- Contact Configuration:DPST-NO, SPST-NC; Coil Voltage:24VDC; Contact Current:10A; Product Range:7S Series; Relay Mounting:DIN Rail; Coil Type:-; Contact Voltage VAC:250V; Relay Te
- SVHC: No SVHC (04-Feb-2026)
- IP Rating: IP20
- Coil Voltage: 24VDC
- Product Range: 7S Series
- Relay Mounting: DIN Rail
- Contact Current: 10A
- Relay Terminals: Screw
- Contact Material: Silver Nickel Gold
- Contact Configuration: DPST-NO, SPST-NC
- Contact Voltage AC Nom: 250V
- Contact Voltage DC Nom: -
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 41.54 € |
| Current stock | 500+ |
| Lead time | 30 days |
7S SЕRIES
## Modular relays with forcibly guided contacts 6 - 10 A
Chemical and petrolchemical Hoists and cranes
Woodprocessing machines
Carousel warehouses
Escalators
Elevators and lifts Process Industry
Automatic car-washes
Prices, features, specifications, capabilities, appearance and availability of our products and services are subject to change without notice. FINDER assumes no responsibility for the presence of possible errors or insufficient information in this document. In case of discrepancies between the printed and online versions, the latter prevails.
7S SERIES
C
**Modular relays with forcibly guided contacts Type 7S.12/32** - 2 pole 6 A (1 NO + 1 NC) **Type 7S.14/34** - 4 pole 6 A (2 NO + 2 NC and 3 NO + 1 NC) **Type 7S.16/36** - 6 pole 6 A (4 NO + 2 NC and 5 NO + 1 NC)
- For safety applications, with class A forcibly guided contact relays EN 61810-3 (previously EN 50205)
- • SIL2 evaluated according to EN 61508, for use in functional safety application according to EN 62061 up to SIL2 and according to IEC 13849-1 up to PL d (instead of For functional reliability in machinery and plant engineering according to EN 13849-1)
- • For functional reliability in machinery and plant engineering according to EN 13849-1
- • Railways application versions available • DC and AC supply versions • Coil status visual indication with LED • 35 mm rail (EN 60715) mount
**7S.12/32…5110 7S.14/34…4xx0 7S.16/36…5xx0** • 2 pole (1 NO + 1 NC) • 4 pole : • 6 pole: (2 NO + 2 NC) type (4 NO + 2 NC) type 7S.xx.x.xxx.4220 7S.xx.x.xxx.5420 (3 NO + 1 NC) type (5 NO + 1 NC) type 7S.xx.x.xxx.4310 7S.xx.x.xxx.5510
|**Modular relays with forcibly guided contacts**<br>**Type 7S.12/32**<br>- 2 pole 6 A (1 NO + 1 NC)<br>**Type 7S.14/34**<br>- 4 pole 6 A (2 NO + 2 NC and 3 NO + 1 NC)<br>**Type 7S.16/36**<br>- 6 pole 6 A (4 NO + 2 NC and 5 NO + 1 NC)<br>• For safety applications, with class A forciblyFor safety applications, with class A forcibly<br>guided contact relays EN 61810-3 (previously<br>EN 50205)<br>• SIL2 evaluated according to EN 61508, forSIL2 evaluated according to EN 61508, for<br>use in functional safety application according<br>to EN 62061 up to SIL2 and according to IEC<br>13849-1 up to PL d (instead of For functional<br>reliability in machinery and plant engineering<br>according to EN 13849-1)<br>• For functional reliability in machinery andFor functional reliability in machinery and<br>plant engineering according to EN 13849-1<br>• Railways application versions availableRailways application versions available<br>• DC and AC supply versionsDC and AC supply versions<br>• Coil status visual indication with LEDCoil status visual indication with LED<br>• 35 mm rail (EN 60715) mount35 mm rail (EN 60715) mount<br>Screwless terminal<br>Screw terminal<br>For outline drawing see page 12<br>**Contact specification**<br>Contact configuration<br>~~DR~~|**7S.12/32…5110**<br>• 2 pole (1 NO + 1 NC)2 pole (1 NO + 1 NC)<br>1 NO + 1 NC<br>~~DR~~|**7S.14/34…4xx0**<br>• 4 pole :4 pole :<br>(2 NO + 2 NC) type<br>7S.xx.x.xxx.4220<br>(3 NO + 1 NC) type<br>7S.xx.x.xxx.4310<br>2 NO + 2 NC, 3 NO + 1 NC|**7S.16/36…5xx0**<br>• 6 pole:6 pole:<br>(4 NO + 2 NC) type<br>7S.xx.x.xxx.5420<br>(5 NO + 1 NC) type<br>7S.xx.x.xxx.5510<br>4 NO + 2 NC, 5 NO + 1 NC|
|---|---|---|---|
|Rated current/Max. peak current<br>A<br>~~DR~~|6/15<br>~~DR~~|6/15|6/15|
|Rated switching voltage<br>V AC (50/60 Hz)<br>~~DR~~|250<br>~~DR~~<br>~~Ds~~|250<br>~~Ds~~|250<br>~~Ds~~|
|Rated load AC1<br>VA|1500<br>~~Ds~~<br>~~Ds~~|1500<br>~~Ds~~<br>~~Ds~~|1500<br>~~Ds~~<br>~~Ds~~|
|Rated current AC15 (230 V AC)<br>A|5<br>~~Ds~~<br>~~Ds~~|5<br>~~Ds~~<br>~~Ds~~|5<br>~~Ds~~<br>~~Ds~~|
|Rated current AC15 (400 V AC)<br>A|2<br>~~Ds~~<br>~~DR~~|—<br>~~Ds~~<br>~~DR~~|—<br>~~Ds~~<br>~~DR~~|
|Breaking capacity DC1: 24/110/220 V<br>A|6/0.6/0.2<br>~~DR~~<br>~~Ds~~|6/0.9/0.3<br>~~DR~~<br>~~Ds~~|6/0.9/0.3<br>~~DR~~<br>~~Ds~~|
|Breaking capacity DC13: 24 V<br>A<br>~~DR~~|1<br>~~Ds~~<br>~~DR~~|3<br>~~Ds~~|3<br>~~Ds~~|
|Minimum switching load<br>mW (V/mA)<br>~~DR~~|60 (5/5)<br>~~DR~~|60 (5/10)|60 (5/10)|
|Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC<br>~~DR~~|AgNi + Au<br>110…125 - 230…240<br>~~DR~~|AgSnO2<br>110…125 - 230…240|AgSnO2+Au<br>110…125 - 230…240|
||12 - 24<br>~~Rs~~|12 - 24 - 110<br>~~Rs~~|12 - 24 - 110<br>~~Rs~~|
|Rated power<br>VA (50 Hz)/W|2.3/1<br>~~Rs~~|2.3/1<br>~~Rs~~|2.3/1<br>~~Rs~~|
|Operating range<br>AC<br>DC<br>DC (24 and 110 V only)<br>~~LR~~|(0.85…1.1)UN<br>~~es~~|(0.85…1.1)UN<br>~~es~~|(0.85…1.1)UN<br>~~es~~|
||(0.8…1.2)UN<br>~~es~~|(0.8…1.2)UN<br>~~es~~|(0.8…1.2)UN<br>~~es~~|
||(0.7…1.25)UN<br>~~es~~<br>~~LR~~|(0.7…1.25)UN<br>~~es~~|(0.7…1.25)UN<br>~~es~~|
|Holding voltage<br>AC/DC<br>~~LR~~|0.45 UN/ 0.45 UN<br>~~LR~~|0.55 UN/ 0.55 UN|0.55 UN/ 0.55 UN|
|Must drop-out voltage<br>AC/DC<br>**Technical data**<br>Mechanical life<br>cycles<br>~~LR~~|0.1 UN/ 0.1 UN<br>10 · 106<br>~~LR~~|0.1 UN/ 0.1 UN<br>10 · 106|0.1 UN/ 0.1 UN<br>10 · 106|
|Electrical life at rated load AC1<br>cycles|100 · 103|100 · 103|100 · 103|
|Operate/release time<br>ms|7/11|12/10|12/10|
|Insulation between coil and contacts (1.2/50 µs) kV|6<br>~~DR~~|6<br>~~DR~~|6<br>~~DR~~|
|Dielectric strength between open contacts V AC|1500<br>~~Ds~~|1500<br>~~Ds~~|1500<br>~~Ds~~|
|Ambient temperature<br>°C|–40…+70<br>~~Ds~~|–40…+70<br>~~Ds~~|–40…+70<br>~~Ds~~|
|Protection category<br>**Approvals**(according to type)|IP 20<br>IP 20<br>IP 20<br>~~Rs~~<br>C€csFALsiz@«|||
**3**
7S SERIES
## **Modular relays with forcibly guided contacts**
## **7S.23**
## **Type 7S.23**
- 3 pole (2 NO + 1 NC)
- For safety applications, with class A forcibly guided contact relays EN 61810-3 (previously EN 50205)
- SIL2 evaluated according to EN 61508, for use in functional safety application according to EN 62061 up to SIL2 and according to IEC 13849-1 up to PL d (instead of For functional reliability in machinery and plant engineering according to EN 13849-1)
- For functional reliability in machinery and
- C plant engineering according to EN 13849-1
- DC coil
- 3 pole (2 NO + 1 NC)
- Cadmium free contacts
- 17.5 mm wide
- Coil status visual indication with LED
- 35 mm rail (EN 60715) mount
Screw terminal
|For outline drawing see page 12|||
|---|---|---|
|**Contact specification**<br>Contact configuration||2 NO + 1 NC|
|Rated current/Max. peak current|A|10/20<br>~~eee~~|
|Rated switching voltage|V AC (50/60 Hz)|250<br>~~eee~~|
|Rated load AC1|VA|2500<br>~~eee~~|
|Rated current AC15 (230 V AC)|A|5<br>~~a~~|
|Breaking capacity DC1: 24/110/220 V<br>A||10/0.6/0.3<br>~~eee~~|
|Breaking capacity DC13: 24 V|A|5<br>~~eee~~|
|Minimum switching load|mW (V/mA)|60 (5/5)<br>~~eee~~|
|Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)|V DC|AgNi + Au<br>12 - 24 - 48 -110|
|Rated power<br>Operating range<br>Holding voltage|W<br>DC<br>DC|1<br>(0.8…1.2)UN<br>0.45 UN<br>~~a~~<br>~~a~~<br>~~a~~|
|Must drop-out voltage<br>**Technical data**|DC|0.1 UN|
|Mechanical life|cycles|10 · 106|
|Electrical life at rated load AC1|cycles|100 · 103<br>~~eee~~|
|Operate/release time|ms|7/11<br>~~eee~~|
|Insulation between coil and contacts (1.2/50 µs) kV||6<br>~~eee~~|
|Dielectric strength between open contacts V AC|Dielectric strength between open contacts V AC|1500<br>~~eee~~|
|Ambient temperature|°C|–40…+70<br>~~a~~|
|Protection category||IP 20<br>~~Pe~~|
|**Approvals**(according to type)||C€UKFALsz@s|
**4**
7S SERIES
C
**Modular relays with forcibly guided contacts 7S.43/63…0211 for SIL3 safety applications**
## **Type 7S.43/63**
- 2 NO safety contacts
- 1 NC feedback contact
- 1 auxiliary signalling contact
- For safety application, with class A forcibly guided contact relays EN 61810-3 (previously EN 50205) for safety application up to SIL 3
- SIL 3 evaluated according to EN 61508, for use in functional safety application according to EN 62061 up to SIL 3 and according to IEC 13849-1 up to PL e • 3 pole (2 NO + 1 NC)
- • Double channel architecture (1oo2) with • 1 auxliary contact 2 NO contact, 1 feedback contact and 1 auxiliary contact
- From 12 up to 110 V DC version with operating range (0.85…1.1)UN
- DC coil
- Coil status visual indication with LED
- 35 mm rail (EN 60715) mount
Screwless terminal Screw terminal
For outline drawing see page 12
||For outline drawing see page 12||
|---|---|---|
||**Contact specification**<br>Contact configuration|2 NO + 1 NC + 1 AUX|
||Rated current/Max. peak current|A<br>6/15<br>~~Ps~~|
||Rated switching voltage<br>V AC (50/60 Hz)<br>250<br>~~Ps~~||
||Rated load AC1|VA<br>1500<br>~~Pe~~|
||Rated current AC15 (230 V AC)|A<br>5<br>~~Pe~~|
||Breaking capacity DC1: 24/110/220 V|A<br>6/0.6/0.2<br>~~Ps~~|
||Breaking capacity DC13: 24 V|A<br>3<br>~~Ps~~|
||Minimum switching load|mW (V/mA)<br>60 (5/10)<br>~~Pe~~|
||Standard contact material<br>**Coil specification**<br>Nominal voltage (UN)|AgSnO2& AgNi+Au<br>V DC<br>12 - 24 - 48 -110|
||Rated power<br>Operating range|W<br>1.7<br>DC<br>(0.85…1.1)UN<br>~~Pe~~<br>~~PO~~|
||Holding voltage|DC<br>0.55 UN<br>~~Pe~~|
||Must drop-out voltage<br>**Technical data**|DC<br>0.1 UN|
||Mechanical life|cycles<br>10 · 106|
||Electrical life at rated load AC1|cycles<br>100 · 103<br>~~Ps~~|
||Operate/release time of NO contacts|ms<br>10/7<br>~~Ps~~|
||Operate/release time of NC contacts|ms<br>5/30<br>~~Ps~~|
|XII-2023, www.findernet.com|Insulation between coil and contacts (1.2/50 µs) kV<br>6<br>Dielectric strength between open contacts V AC<br>1500<br>Ambient temperature<br>°C<br>–40…+70<br>Protection category<br>IP 20<br>**Approvals**(according to type)<br>~~Pe~~<br>~~Pe~~<br>~~Ps~~<br>~~PE~~<br>C€ 2K FAL sus @«||
**5**
7S SERIES
## **Ordering information**
Example: 7S series Modular relay with forcibly guided contacts, 6 contact (4 NO + 2 NC) 6 A, supply voltage 24 V DC.
**7 S . 1 6 . 9 . 0 2 4 . 5 4 2 0**
## **Series**
C
## **Type**
- 1 = 22.5 mm wide, screwless terminals 2 = 17.5 mm wide, screw terminals
3 = 22.5 mm wide, screw terminals
4 = 22.5 mm wide, screwless terminals
6 = 22.5 mm wide, screw terminals
## **Output**
2 = 2 contacts
3 = 3 contacts 4 = 4 contacts 6 = 6 contacts
## **Supply version**
8 = AC (50 /60 Hz) 9 = DC
**Supply voltage**
See page 10
T= Railways application version
## **Special versions**
0 = Standard 1 = NO auxliary contact
## **NO and NC contatcs**
11 = 1 NO + 1 NC (SPST-NO + SPST-NC) 21 = 2 NO + 1 NC (DPST-NO+SPST-NC) 22 = 2 NO + 2 NC (DPST-NO + DPST-NC) 31 = 3 NO + 1 NC (3PST-NO + SPST-NC) 42 = 4 NO + 2 NC (4PST-NO + DPST-NC) 51 = 5 NO + 1 NC (4PST-NO + SPST-NC)
## **Contact material**
0 = AgNi +Au (7S.23) only
0 = AgSnO2 & AgNi + Au (7S.43/63) only 4 = AgSnO2 (7S.14/34) only 5 = AgNi +Au (7S.12/32) only
5 = AgSnO2 + Au (7S.16/36) only
**Codes,** Preferred selections for best availability are shown in **bold.**
7S.12.9.012.5110 7S.14.9.012.4220 7S.16.9.012.5420 **7S.12.9.024.5110** 7S.14.9.012.4310 **7S.16.9.024.5420** 7S.12.8.120.5110 **7S.14.9.024.4220 7S.16.9.024.5510** 7S.12.8.230.5110 **7S.14.9.024.4310** 7S.16.9.110.5420 7S.14.9.110.4220 7S.16.8.120.5420 7S.32.9.012.5110 7S.14.9.110.4310 7S.16.8.230.5420 **7S.32.9.024.5110** 7S.14.8.120.4220 7S.32.8.120.5110 7S.14.8.120.4310 7S.36.9.012.5420 7S.32.8.230.5110 7S.14.8.230.4220 **7S.36.9.024.5420** 7S.14.8.230.4310 **7S.36.9.024.5510** 7S.43.9.012.0211 7S.36.9.110.5420 **7S.43.9.024.0211** 7S.34.9.012.4220 7S.36.8.120.5420 7S.43.9.048.0211 7S.34.9.012.4310 7S.36.8.230.5420 7S.43.9.110.0211 **7S.34.9.024.4220 7S.34.9.024.4310** 7S.23.9.012.0210 7S.63.9.012.0211 7S.34.9.110.4220 **7S.23.9.024.0210 7S.63.9.024.0211** 7S.34.9.110.4310 7S.23.9.048.0210 7S.63.9.048.0211 7S.34.8.120.4220 7S.23.9.110.0210 7S.63.9.110.0211 7S.34.8.120.4310 7S.34.8.230.4220 7S.34.8.230.4310
**6**
7S SERIES
## **Technical data**
**==> picture [512 x 476] intentionally omitted <==**
**----- Start of picture text -----**<br>
Insulation according to EN 61810-1<br>Nominal voltage of supply system V AC 230/400<br>Rated insulation voltage V AC 250<br>Pollution degree 2<br>Insulation between coil and contact set<br>Type of Insulation Reinforced<br>Overvoltage category III<br>Rated impulse voltage kV (1.2/50 µs) 6<br>Dielectric strength V AC 4000<br>Insulation between adjacent contacts<br>Type of Insulation Basic<br>Overvoltage category III<br>Rated impulse voltage kV (1.2/50 µs) 4<br>Dielectric strength V AC 2500<br>Insulation between open contacts<br>Type of disconnection Micro-disconnection<br>Dielectric strength V AC/kV (1.2/50 µs) 1500/2.5<br>Insulation between coil terminals<br>Rated impulse voltage (surge) differential mode<br>(according to EN 61000-4-5) kV (1.2/50 µs) 1.5<br>Terminals Screw Terminal Screwless Terminal<br>Min. wire size solid cable stranded cable solid cable stranded cable<br>mm [2] 0.5 0.5 0.5 0.5<br>AWG 21 21 21 21<br>Screw Terminal Screwless Terminal<br>Max. wire size solid cable stranded cable solid cable stranded cable<br>mm [2] 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5 1 x 1.5 1 x 1.5<br>AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14 1 x 14 1 x 16<br>Wire strip length mm 9<br>Other data 7S.12/32 7S.14/34 7S.16/36 7S.23 7S.43/63<br>Bounce time: NO/NC ms 2/8 2/10 2/10 2/15 1/8<br>Vibration resistance (10…200)Hz: NO/NC g 10/5 20/6 20/6 10/2 10/2<br>Shock resistance: NO/NC g 20/6 20/5 20/5 20/6 20/5<br>Power lost to the environment without contact current W 0.8 0.8 0.8 0.8 1.7<br>with rated current W 1.4 2.3 2.8 1.4 3.8<br>**----- End of picture text -----**<br>
C
**7**
7S SERIES
## **Contact specifications**
**==> picture [540 x 346] intentionally omitted <==**
**----- Start of picture text -----**<br>
Contact diagrams<br>7S.12/7S.32 7S.14/34…4220 7S.14…4310 7S.16/36…5420 7S.16/36…5510<br>12 34<br>11 33<br>11 12<br>43<br>C<br>54 33 34<br>7S.23 7S.43/7S.63<br>23 47<br>24 48<br>11 33 23<br>47 48<br>12 34 24<br>**----- End of picture text -----**<br>
## **F 7S12 - Electrical life (AC) v contact current - 7S.12**
**==> picture [216 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load - cosφ = 1<br>Inductive load - AC15<br>Cycles<br>**----- End of picture text -----**<br>
## **H 7S12* - Maximum DC breaking capacity - 7S.12**
**==> picture [215 x 123] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load<br>Inductive load - DC13<br>Tensione DC (V)<br>Corrente DC (A)<br>**----- End of picture text -----**<br>
## **F 7S14 - Electrical life (AC) v contact current - 7S.14/34**
**==> picture [218 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load - cosφ = 1<br>Inductive load - AC15<br>2 4 6 8<br>Cycles<br>**----- End of picture text -----**<br>
## **H 7S14* - Maximum DC1 breaking capacity - 7S.14/34**
**==> picture [214 x 127] intentionally omitted <==**
**----- Start of picture text -----**<br>
Tensione DC (V)<br>Corrente DC (A)<br>**----- End of picture text -----**<br>
* When switching a load having voltage and current values under the curve, an electrical life of ≥ 100 · 10[3] can be expected.
**8**
7S SERIES
C
## **Contact specifications**
**F 7S16 - Electrical life (AC) v contact current - 7S.16/36**
**==> picture [218 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load - cosφ = 1<br>Inductive load - AC15<br>2 4 6 8<br>Cycles<br>**----- End of picture text -----**<br>
**F 7S23 - Electrical life (AC) v contact current - 7S.23**
**==> picture [215 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load - cosφ = 1<br>Inductive load - AC15<br>Cycles<br>**----- End of picture text -----**<br>
**F 7S43 - Electrical life (AC) v contact current - 7S.43/63**
**==> picture [217 x 114] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load - cosφ = 1<br>Inductive load - AC15<br>2 4 6 8<br>Cycles<br>**----- End of picture text -----**<br>
## **H 7S16* - Maximum DC1 breaking capacity - 7S.16/36**
**==> picture [214 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC voltage (V)<br>DC breaking current (A)<br>**----- End of picture text -----**<br>
## **H 7S23* - Maximum DC breaking capacity - 7S.23**
**==> picture [215 x 126] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load<br>Inductive load - DC13<br>DC voltage (V)<br>DC breaking current (A)<br>**----- End of picture text -----**<br>
## **H 7S43* - Maximum DC breaking capacity - 7S.43/63**
**==> picture [215 x 124] intentionally omitted <==**
**----- Start of picture text -----**<br>
Resistive load<br>Inductive load - DC13<br>DC voltage (V)<br>DC breaking current (A)<br>**----- End of picture text -----**<br>
* When switching a load having voltage and current values under the curve, an electrical life of ≥ 100 · 10[3] can be expected.
## **H 7S14/34 - Maximum DC13 breaking capacity - 7S.14/34**
**==> picture [261 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC voltage (V)<br>DC breaking current (A)<br>XII-2023, www.findernet.com<br>**----- End of picture text -----**<br>
## **H 7S16/36 - Maximum DC13 breaking capacity - 7S.16/36**
**==> picture [214 x 128] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC voltage (V)<br>DC breaking current (A)<br>**----- End of picture text -----**<br>
**9**
7S SERIES
## **Coil specifications**
**DC coil data - type 7S.12/32**
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Rated input<br>current<br>at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|
|V||V|V|mA|W|
|12|**9**.012|9.6|14.4|55|0.7|
|24|**9**.024|16.8|30|38.2|0.9|
|C|**DC coil data - type 7S.14/34 / 7S.16/36**|**DC coil data - type 7S.14/34 / 7S.16/36**|**DC coil data - type 7S.14/34 / 7S.16/36**|**DC coil data - type 7S.14/34 / 7S.16/36**|**DC coil data - type 7S.14/34 / 7S.16/36**|**DC coil data - type 7S.14/34 / 7S.16/36**|
|---|---|---|---|---|---|---|
||Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax||Rated input<br>current<br>at UN<br>IN|Rated<br>power<br>at UN|
||V||V|V|mA|W|
||12|**9**.012|9.6|14.4|64.7|0.8|
||24|**9**.024|16.8|30|42.2|1|
||110|**9**.110|77|138|11.6|1.4|
## **DC coil data - type 7S.23**
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Rated input<br>current<br>at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|
|V||V|V|mA|W|
|12|**9**.012|9.6|14.4|47.1|0.6|
|24|**9**.024|16.8|30|26.6|0.6|
|48|**9**.048|33.6|60|16.2|0.8|
|110|**9**.110|77|138|8.8|1|
**R 7S - DC coil operating range v ambient temperature - 7S.12/32 / 7S.23 / 7S.14/34 / 7S.16/36**
**==> picture [216 x 118] intentionally omitted <==**
**==> picture [104 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 - Max. permitted coil voltage.<br>**----- End of picture text -----**<br>
**2 -** Min. pick-up voltage with coil at ambient temperature.
**AC coil data - type 7S.12/32**
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Rated input<br>current<br>at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|
|V||V|V|mA|VA/W|
|110…125|**8**.120|93|138|9.8|1.2/1.1|
|230…240|**8**.230|195|264|11.8|2.8/1.2|
## **AC coil data - type 7S.14/34 / 7S.16/36**
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Rated input<br>current<br>at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|
|V||V|V|mA|VA/W|
|110…125|**8**.120|93|138|10.2|1.3/1.1|
|230…240|**8**.230|195|264|11.8|2.9/1.2|
## **DC coil data - type 7S.43/63**
|Nominal<br>voltage<br>UN|Coil<br>code|Operating range<br>Umin<br>Umax|Operating range<br>Umin<br>Umax|Rated input<br>current<br>at UN<br>IN|Rated<br>power<br>at UN|
|---|---|---|---|---|---|
|V||V|V|mA|W|
|12|**9**.012|10.2|13.2|105|1.3|
|24|**9**.024|20.4|26.4|60|1.45|
|48|**9**.048|40.8|52.8|36|1.6|
|110|**9**.110|93.5|121|20|1.7|
**R 7S - AC coil operating range v ambient temperature - 7S.12/32 / 7S.14/34 / 7S.16/36**
**==> picture [216 x 118] intentionally omitted <==**
**==> picture [104 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 - Max. permitted coil voltage.<br>**----- End of picture text -----**<br>
- **2 -** Min. pick-up voltage with coil at ambient temperature.
- **- - - -** 24 and 110 V DC coils only excluding 7S.23
## **R 7S - DC coil operating range v ambient temperature - 7S.43/63**
**==> picture [207 x 114] intentionally omitted <==**
- **1 -** Max. permitted coil voltage.
- **2 -** Min. pick-up voltage with coil at ambient temperature.
**10**
7S SERIES
## **Example wiring diagrams**
**==> picture [511 x 616] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type 7S.x2 Type 7S.x4…4220<br>Safety PLC<br>feedback<br>output<br>Safety PLC<br>feedback<br>output<br>feedback<br>Type 7S.43<br>Safety PLC L<br>feedback<br>output<br>K1<br>K2<br>K3<br>K4<br>23 47<br>48<br>K2 K3<br>feedback<br>3<br>K1 K4<br>4<br>**----- End of picture text -----**<br>
**==> picture [30 x 53] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>**----- End of picture text -----**<br>
**11**
7S SERIES
## **Outline drawings**
**==> picture [301 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Types 7S.12/14/16/43 Type 7S.23<br>Screwless terminal Screw terminal<br>**----- End of picture text -----**<br>
**==> picture [8 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
C<br>**----- End of picture text -----**<br>
**==> picture [301 x 15] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type 7S.32 Type 7S.34<br>Screw terminal Screw terminal<br>**----- End of picture text -----**<br>
**==> picture [494 x 177] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type 7S.36 Type 7S.63<br>Screw terminal Screw terminal<br>22 . 5 4 . 3 96 22.5 4.3 96<br>| |<br>|. 82 geQe oO<br>oooo A oooo A<br>eeee| re ) ee) ee)<br>33.8 59.5 78.8<br>86.2<br>30.5<br>**----- End of picture text -----**<br>
**==> picture [62 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Accessories<br>**----- End of picture text -----**<br>
**==> picture [289 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Sheet of marker tags, plastic, 48 tags, 6 x 12 mm, for CEMBRE thermal transfer printers<br>**----- End of picture text -----**<br>
**==> picture [23 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
060.48<br>**----- End of picture text -----**<br>
**060.48**
Please see general technical information
**12**
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →