Image not available
Illustrative purposes only
3RW5248-2TC04
Soft Starter, 3RW Series, Three Phase, 570 A, 200 V to 480 V, 315 kW at 400 V, Spring Terminal
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Motor Starters
- SVHC: To Be Advised
- No. of Poles: 3 Pole
- Power Rating: 315kW
- No. of Phases: Three Phase
- Product Range: 3RW52
- Current Rating: 570A
- IP / NEMA Rating: IP00
- Motor Starter Type: Soft Starter
- Supply Voltage Max: 480VAC
- Supply Voltage Min: 200VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 5655.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
**3RW5248-2TC04** **Data sheet** SIRIUS soft starter 200-480 V 570 A, 24 V AC/DC spring-type terminals Thermistor input |SIRIUS soft starter 200-480 V 570 A, 24 V AC/DC spring-type terminals Thermistor<br>input<br>**product brand name**<br>SIRIUS<br>**product category**<br>Hybrid switchingdevices<br>**product designation**<br>Soft starter<br>**product type designation**<br>3RW52<br>**manufacturer's article number**<br>● of standard HMI module usable<br>3RW5980-0HS00<br>● of high feature HMI module usable<br>3RW5980-0HF00<br>● of communication module PROFINET standard usable<br>3RW5980-0CS00<br>● of communication module PROFIBUS usable<br>3RW5980-0CP00<br>● of communication module Modbus TCP usable<br>3RW5980-0CT00<br>● of communication module Modbus RTU usable<br>3RW5980-0CR00<br>● of communication module Ethernet/IP<br>3RW5980-0CE00<br>● of circuit breaker usable at 400 V<br>3VA2580-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10<br>● of circuit breaker usable at 500 V<br>3VA2580-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10<br>● of circuit breaker usable at 400 V at inside-delta circuit<br>3VA2510-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10<br>● of circuit breaker usable at 500 V at inside-delta circuit<br>3VA2510-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10<br>● of thegG fuse usable upto 690 V<br>2x3NA3365-6; Type of coordination 1, Iq= 65 kA<br>● of thegG fuse usable at inside-delta circuit upto 500 V<br>2x3NA3365-6; Type of coordination 1, Iq= 65 kA<br>● of full range R fuse link for semiconductor protection<br>usable upto 690 V<br>3NE1437-2; Type of coordination 2, Iq=65 kA<br>● of back-up R fuse link for semiconductor protection<br>usable up to 690 V<br>3NE3340-8; Type of coordination 2, Iq=65 kA<br>**General technical data**<br>**starting voltage [%]**<br>30 ... 100 %<br>**stopping voltage [%]**<br>50 %; non-adjustable<br>**start-up ramp time of soft starter**<br>0 ... 20 s<br>**current limiting value[%] adjustable**<br>130 ... 700 %<br>**certificate of suitability**<br>● CE marking<br>Yes<br>● UL approval<br>Yes<br>● CSA approval<br>Yes<br>**product component**<br>● HMI-High Feature<br>No<br>● is supported HMI-Standard<br>Yes<br>● is supported HMI-High Feature<br>Yes<br>**product feature integrated bypass contact system**<br>Yes<br>**number of controlled phases**<br>3<br>Siemens<br>EcoTech<br>E|SIRIUS soft starter 200-480 V 570 A, 24 V AC/DC spring-type terminals Thermistor<br>input|| |---|---|---| ||SIRIUS|| ||Hybrid switchingdevices|| ||Soft starter|| ||3RW52|| |||| ||3RW5980-0HS00|| ||3RW5980-0HF00|| ||3RW5980-0CS00|| ||3RW5980-0CP00|| ||3RW5980-0CT00|| ||3RW5980-0CR00|| ||3RW5980-0CE00|| ||3VA2580-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10|| ||3VA2580-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10|| ||3VA2510-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10|| ||3VA2510-6HN32-0AA0; Type of coordination 1, Iq=65 kA, CLASS 10|| ||2x3NA3365-6; Type of coordination 1, Iq= 65 kA|| ||2x3NA3365-6; Type of coordination 1, Iq= 65 kA|| ||3NE1437-2; Type of coordination 2, Iq=65 kA|| ||3NE3340-8; Type of coordination 2, Iq=65 kA|| ||30 ... 100 %|| ||50 %; non-adjustable|| ||0 ... 20 s|| ||130 ... 700 %|| |||| ||Yes|| ||Yes|| ||Yes|| |||| ||No|| ||Yes|| ||Yes|| ||Yes|| ||3|| 3RW52482TC04 Page 1/9 Subject to change without notice © Copyright Siemens 5/31/2026 |**buffering time in the event ofpower failure**|| |---|---| |● for main current circuit|100 ms| |● for control circuit|100 ms| |**insulation voltage rated value**|600 V| |**degree ofpollution**|3, acc. to IEC 60947-4-2| |**impulse voltage rated value**|6 kV| |**blocking voltage of the thyristor maximum**|1 600 V| |**service factor**|1| |**surge voltage resistance rated value**|6 kV| |**maximumpermissible voltage forprotective separation**|| |● between main and auxiliarycircuit|600 V| |**shock resistance**|15g/ 11 ms, from 12g/ 11 ms withpotential contact lifting| |**vibration resistance**|15 mm to 6 Hz; 2gto 500 Hz| |utilization categoryaccordingto IEC 60947-4-2|AC 53a| |**reference code according to IEC 81346-2**|Q| |**Substance Prohibitance(day/month/year)**|02/15/2018| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol CAS-No. 79-94-7<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1<br>6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1<br>Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-No. 22673-19-4| |**Net Weight**|12.034 kg| |**product function**|| |● ramp-up (soft starting)|Yes| |● soft stopping|Yes| |● Soft Torque|Yes| |● adjustable current limitation|Yes| |●pumpstop|Yes| |● intrinsic deviceprotection|Yes| |● motor overload protection|Yes; Full motor protection (thermistor motor protection and electronic motor<br>overloadprotection)| |● evaluation of thermistor motorprotection|Yes; Type A PTC or Klixon / Thermoclick| |● inside-delta circuit|Yes| |● auto-RESET|Yes| |● manual RESET|Yes| |● remote reset|Yes; Byturningoff the control supplyvoltage| |● communication function|Yes| |● operatingmeasured value display|Yes; Onlyin conjunction with special accessories| |● error logbook|Yes; Onlyin conjunction with special accessories| |● via softwareparameterizable|No| |● via software configurable|Yes| |**● PROFIenergy**|Yes; in connection with the PROFINET Standard communication module| |**● firmware update**|Yes| |**● removable terminal for control circuit**|Yes| |● torque control|No| |● analogoutput|No| |**Power Electronics**|| |**operational current**|| |● at 40 °C rated value|570 A| |● at 50 °C rated value|504 A| |● at 60 °C rated value|460 A| |**operational current at inside-delta circuit**|| |● at 40 °C rated value|987 A| |● at 50 °C rated value|873 A| |● at 60 °C rated value|796 A| |**operating voltage**|| |● rated value|200 ... 480 V| |● at inside-delta circuit rated value|200 ... 480 V| 3RW52482TC04 Page 2/9 Subject to change without notice © Copyright Siemens 5/31/2026 |**relative negative tolerance of the operating voltage**|-15 %| |---|---| |**relativepositive tolerance of the operating voltage**|10 %| |**relative negative tolerance of the operating voltage at**<br>**inside-delta circuit**|-15 %| |**relative positive tolerance of the operating voltage at**<br>**inside-delta circuit**|10 %| |**operating power for 3-phase motors**|| |● at 230 V at 40 °C rated value|160 kW| |● at 230 V at inside-delta circuit at 40 °C rated value|315 kW| |● at 400 V at 40 °C rated value|315 kW| |● at 400 V at inside-delta circuit at 40 °C rated value|560 kW| |**Operating frequency 1 rated value**|50 Hz| |**Operating frequency 2 rated value**|60 Hz| |**relative negative tolerance of the operating frequency**|-10 %| |**relativepositive tolerance of the operating frequency**|10 %| |**adjustable motor current**|| |● at rotarycodingswitch on switchposition 1|240 A| |● at rotarycodingswitch on switchposition 2|262 A| |● at rotarycodingswitch on switchposition 3|284 A| |● at rotarycodingswitch on switchposition 4|306 A| |● at rotarycodingswitch on switchposition 5|328 A| |● at rotarycodingswitch on switchposition 6|350 A| |● at rotarycodingswitch on switchposition 7|372 A| |● at rotarycodingswitch on switchposition 8|394 A| |● at rotarycodingswitch on switchposition 9|416 A| |● at rotarycodingswitch on switchposition 10|438 A| |● at rotarycodingswitch on switchposition 11|460 A| |● at rotarycodingswitch on switchposition 12|482 A| |● at rotarycodingswitch on switchposition 13|504 A| |● at rotarycodingswitch on switchposition 14|526 A| |● at rotarycodingswitch on switchposition 15|548 A| |● at rotarycodingswitch on switchposition 16|570 A| |● minimum|240 A| |**adjustable motor current**|| |● for inside-delta circuit at rotary coding switch on switch<br>position 1|416 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 2|454 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 3|492 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 4|530 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 5|568 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 6|606 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 7|644 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 8|682 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 9|721 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 10|759 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 11|797 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 12|835 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 13|873 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 14|911 A| |● for inside-delta circuit at rotary coding switch on switch<br>position 15|949 A| 3RW52482TC04 Page 3/9 Subject to change without notice © Copyright Siemens 5/31/2026 |● for inside-delta circuit at rotary coding switch on switch<br>position 16|987 A| |---|---| |● at inside-delta circuit minimum|416 A| |**minimum load[%]**|15 %; Relative to smallest settable Ie| |**power loss[W] for rated value of the current at AC**|| |● at 40 °C after startup|183 W| |● at 50 °C after startup|163 W| |● at 60 °C after startup|153 W| |**power loss[W] at AC at current limitation 350 %**|| |● at 40 °C duringstartup|10 241 W| |● at 50 °C duringstartup|8 500 W| |● at 60 °C duringstartup|7 663 W| |**Control circuit/ Control**|| |**type of voltage of the control supply voltage**|AC/DC| |**control supply voltage at AC**|| |● at 50 Hz rated value|24 V| |● at 60 Hz rated value|24 V| |**relative negative tolerance of the control supply voltage at**<br>**AC at 50 Hz**|-20 %| |**relative positive tolerance of the control supply voltage at**<br>**AC at 50 Hz**|20 %| |**relative negative tolerance of the control supply voltage at**<br>**AC at 60 Hz**|-20 %| |**relative positive tolerance of the control supply voltage at**<br>**AC at 60 Hz**|20 %| |**control supply voltage frequency**|50 ... 60 Hz| |**relative negative tolerance of the control supply voltage**<br>**frequency**|-10 %| |**relative positive tolerance of the control supply voltage**<br>**frequency**|10 %| |**control supply voltage at DC rated value**|24 V| |**relative negative tolerance of the control supply voltage at**<br>**DC**|-20 %| |**relative positive tolerance of the control supply voltage at**<br>**DC**|20 %| |**control supply current in standby mode rated value**|160 mA| |**holding current in bypass operation rated value**|470 mA| |**inrush current by closing the bypass contacts maximum**|7.6 A| |inrush current peak at application of control supply voltage<br>maximum|3.3 A| |duration of inrush current peak at application of control supply<br>voltage|12.1 ms| |**design of the overvoltage protection**|Varistor| |**design of short-circuit protection for control circuit**|4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit<br>breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of<br>scope of supply| |**Inputs/ Outputs**|| |**number of digital inputs**|1| |**number of digital outputs**|3| |● notparameterizable|2| |**digital output version**|2 normally-open contacts(NO)/ 1 changeover contact(CO)| |**number of analog outputs**|0| |**switching capacity current of the relay outputs**|| |● at AC-15 at 250 V rated value|3 A| |● at DC-13 at 24 V rated value|1 A| |**Installation/ mounting/ dimensions**|| |**mounting position**|with vertical mounting surface +/-90° rotatable, with vertical mounting surface<br>+/- 22.5° tiltable to the front and back| |**fastening method**|screw fixing| |**height**|393 mm| |**width**|210 mm| |**depth**|203 mm| |required spacing with side-by-side mounting|| 3RW52482TC04 Page 4/9 Subject to change without notice © Copyright Siemens 5/31/2026 |● forwards|10 mm| |---|---| |● backwards|0 mm| |● upwards|100 mm| |● downwards|75 mm| |● at the side|5 mm| |**weight without packaging**|10.6 kg| |**Connections/ Terminals**|| |**type of electrical connection**|| |● for main current circuit|busbar connection| |● for control circuit|spring-loaded terminals| |**width of connection bar maximum**|45 mm| |**wire length for thermistor connection**|| |● with conductor cross-section = 0.5 mm² maximum|50 m| |● with conductor cross-section = 1.5 mm² maximum|150 m| |● with conductor cross-section = 2.5 mm² maximum|250 m| |**type of connectable conductor cross-sections**|| |● for DIN cable lugfor main contacts stranded|2x(50 ... 240 mm²)| |● for DIN cable lugfor main contacts finelystranded|2x(70 ... 240 mm²)| |**type of connectable conductor cross-sections**|| |● for control circuit solid|2x(0.25 ... 1.5 mm²)| |● for control circuit finelystranded with core endprocessing|2x(0.25 ... 1.5 mm²)| |● for AWG cables for control circuit solid|2x(24 ... 16)| |● for AWG cables for control circuit finely stranded with<br>core endprocessing|2x (24 ... 16)| |**wire length**|| |● between soft starter and motor maximum|800 m| |● at the digital inputs at AC maximum|100 m| |● at the digital inputs at DC maximum|1 000 m| |**tightening torque**|| |● for main contacts with screw-type terminals|14 ... 24 N·m| |● for auxiliary and control contacts with screw-type<br>terminals|0.8 ... 1.2 N·m| |**tightening torque[lbf·in]**|| |● for main contacts with screw-type terminals|124 ... 210 lbf·in| |● for auxiliary and control contacts with screw-type<br>terminals|7 ... 10.3 lbf·in| |**Ambient conditions**|| |installation altitude at height above sea level maximum|5 000 m| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C; Please observe deratingat temperatures of 40 °C or above| |● duringstorage and transport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2<br>(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get<br>inside the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2(max. fall height 0.3 m)| |**Electromagnetic compatibility**|| |**EMC emitted interference**|acc. to IEC 60947-4-2: Class A| |**Communication/ Protocol**|| |**communication module is supported**|| |● PROFINET standard|Yes| |● EtherNet/IP|Yes| |● Modbus RTU|Yes| |● Modbus TCP|Yes| |● PROFIBUS|Yes| |**UL/CSA ratings**|| |**manufacturer's article number**|| |**● of the fuse**|| |— usable for Standard Faults up to 575/600 V|Type: Class J / L, max. 1600 A; Iq = 30 kA| 3RW52482TC04 Page 5/9 Subject to change without notice © Copyright Siemens 5/31/2026 **==> picture [512 x 312] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |according to UL| |— usable for High Faults up to 575/600 V according to|Type: Class J / L, max. 1200 A; Iq = 100 kA| |UL| |— usable for Standard Faults at inside-delta circuit up|Type: Class J / L, max. 1600 A; Iq = 30 kA| |to 575/600 V according to UL| |— usable for High Faults at inside-delta circuit up to|Type: Class J / L, max. 1200 A; Iq = 100 kA| |575/600 V according to UL| |operating|power [hp] for 3-phase motors| |● at 200/208 V at 50 °C rated value|150 hp| |● at 220/230 V at 50 °C rated value|200 hp| |● at 460/480 V at 50 °C rated value|400 hp| |● at 200/208 V at inside-delta circuit at 50 °C rated value|300 hp| |● at 220/230 V at inside-delta circuit at 50 °C rated value|350 hp| |● at 460/480 V at inside-delta circuit at 50 °C rated value|750 hp| |contact rating of auxiliary contacts according to UL|R300-B300| |LeeEy|Electrical Safety| |protection class IP on the front according to IEC 60529|IP00; IP20 with cover| |touch protection on the front according to IEC 60529|finger-safe, for vertical contact from the front with cover| |Approvals Certificates| |SS|Environmental Product Declaration| |● global warming potential [CO2 eq] / during manufacturing|84.2 kg| |● global warming potential [CO2 eq] / during sales|2.81 kg| |● global warming potential [CO2 eq] / during operation|721 kg| |● global warming potential [CO2 eq] / after end of life|-21.8 kg| |● global warming potential [CO2 eq] / total|786 kg| |Environment|General Product Approval| **----- End of picture text -----**<br> Environmental Confirmations **General Product Approval EMV Test Certificates Maritime application** - Type Test Certific ates/Test Report Cc **UK** «& Aa ~~_~~ 4 **Maritime application other** Confirmation Confirmation **other** **Further information** ~~sii~~ **Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5248-2TC04 3RW52482TC04 Page 6/9 Subject to change without notice © Copyright Siemens 5/31/2026 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/3RW5248-2TC04 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5248-2TC04&lang=en **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5248-2TC04 **Characteristic curves** https://curves.simaris.siemens.com/curves/<mmp_prod_noCOMP="HAUPT"></mmp_prod__no> **Characteristic: Tripping characteristics, I²t, Let-through current** https://support.industry.siemens.com/cs/ww/en/ps/3RW5248-2TC04/char **Characteristic: Installation altitude** https://www.automation.siemens.com/bilddb/index.aspx?gridview=view2&objkey=G_NSB0_XX_01704&showdetail=true&view=Search **Simulation Tool for Soft Starters (STS)** https://support.industry.siemens.com/cs/ww/en/view/101494917 **==> picture [203 x 225] intentionally omitted <==** 3RW52482TC04 Page 7/9 Subject to change without notice © Copyright Siemens 5/31/2026 **==> picture [400 x 215] intentionally omitted <==** **----- Start of picture text -----**<br> -Q<br>Ks mK<br>a4As |)<br>><br>1/L1 3/L2 5/L3 A1 IN 14/24 95<br>ON/RUN BYPASSED<br>2/T1 4/T2 6/T3 A2 13 NO 23 NO 98 NO 96 NC T22 T12 T11/21<br>**----- End of picture text -----**<br> **last modified:** 4/4/2026 3RW52482TC04 Page 8/9 Subject to change without notice © Copyright Siemens 5/31/2026 3RW52482TC04 Page 9/9 Subject to change without notice © Copyright Siemens 5/31/2026
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →