24PCBFA6D
Pressure Sensor, Miniature, Silicon, 5 psi, Voltage, Differential, 10 V, Straight, 2 mA
- Manufacturer: HONEYWELL
- Product type: Pressure Transducers
- Port Style: Straight
- Product Range: 24PC Series
- Sensor Output: Voltage
- Supply Current: 2mA
- Operating Pressure Max: 5psi
- Pressure Measurement Type: Differential
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 31.14 € |
| Current stock | 25+ |
| Lead time | 7 days |
Miniature Low Pressure Sensors **24PC Series, Uncompensated/Unamplified** 0.5 psi to 250 psi Datasheet ## Miniature Low Pressure Sensors The 24PC Series Miniature Pressure Sensors are small, cost-effective devices intended for use with wet or dry media. These sensors feature proven sensing technology that uses a specialized piezoresistive micromachined sensing element to offer high performance, reliability, and accuracy. Each sensor contains four active piezoresistors that form a Wheatstone bridge. When pressure is applied, the resistance changes and the sensor provides a milliVolt output signal that is proportional to the input pressure. The low power 24PC sensors are designed to accommodate pressures from 0.5 psi to 250 psi and have an operating temperature range of -40 ºC to 85 ºC [-40 ºF to 185 ºF]. The 24PC sensors have the flexibility to be excited with constant current or constant voltage. When driven by constant current, the pressure sensor’s terminal voltage will rise with increasing temperature. The rise in voltage not only temperature compensates the span but also provides an indication of the sensor’s temperature. These sensors can accommodate a variety of wet and dry media that are compatible with polyphthalamide (PPA) plastics and media seals specified in the Nomenclature and Order Guide (see Figure 2). The 24PC sensors are RoHS compliant. They are designed and manufactured according to ISO 9001 standards. ## _**What makes our sensors better?**_ **24PCXXJ6G** - Wet/Wet capability (i.e., liquids on both ports) - Selectable seals available to match media used - Higher pressure ranges for use in high pressure applications - Wide variety of pressure port types - Available in both SIP and DIP packages **24PCXXH6D 24PCXXK2G** 4° For all available configurations, see Table 4. MINIATURE • WET/WET CApAbIlITy • SElECTAblE SEAlS **2** sensing.honeywell.com Features and Benefits ## _**One sensor does the work of two!**_ ## **TrUe weT/weT DifferenTial meDia SenSinG** Provides liquid sensing in differential applications **wiDe oPeraTinG TemPeraTUre ranGe of -40 ºC To 85 ºC** **[-40 ºf To 185 ºf]** Allows use in a wide variety of applications _**By matching pressure ranges to the application, we optimize resolution and improve system accuracy.**_ ## **VarieTy of PreSSUre ranGeS wiTHin 0.5 PSi To 250 PSi** Provides flexibility in customers’ pneumatic designs **abSolUTe, DifferenTial, anD GaGe meaSUremenT TyPeS** Allows customers to choose the sensor that fits their application ## _**Gives customers greater system flexibility in their designs.**_ **VarieTy of PreSSUre PorT TyPeS anD leaD TerminaTionS** Provides application flexibility **alSo aVailable in SmT anD flow-THroUGH PaCKaGe STyleS** Provides added design flexibility > sensing.honeywell.com **3** ## Potential Applications ## **meDiCal** ## **oXyGen ConenTraTorS** May be used to measure the sieve bed pressure to optimize system performance ## **DenTal CHairS** May be used to control the pneumatic pressure in the various dental instruments ## **HemoDialySiS** May be used to monitor the correct pressure to help ensure optimum blood filtration ## **inDUSTrial** ## **waTer ConTrol ValVeS** May be used to monitor the water consumption in homes and buildings ## **irriGaTion eQUiPmenT** May be used to control the water pressure and flow being delivered ## **filTer moniTorinG** May be used to detect when the filters are clogged and need to be replaced ## **PreSSUre ValVeS** May be used to measure and control pressure in industrial processes ## **air ComPreSSorS** May be used to control the pressure being delivered to the end user equipment ## **breaTHalizerS** May be used to measure the exhalation pressure to ensure proper breath analysis **4** sensing.honeywell.com ## 24PC Series, Uncompensated/Unamplified **Table 1. absolute maximum ratings[1]** **==> picture [542 x 93] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic min. Typ. max. Unit note<br>Supply voltage 2.5 10 12 Vdc –<br>Input resistance 4 5 6 kOhm –<br>Output resistance 4 5 6 kOhm –<br>Time response – – 1 ms 2<br>**----- End of picture text -----**<br> 1Absolute maximum ratings are the extreme limits the device will withstand without damage. 2Time required for the output to increase from 10% to 90% of span in response to a step change in input pressure from the specified min. to max. operating pressure. **Table 2. Technical Specifications** **==> picture [543 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristic Parameter<br>Operating temperature range:<br> without EPDM seals -40 °C to 85 °C [-40 °F to 185 °F]<br> with EPDM seals -20 °C to 85 °C [-4 °F to 185 °F]<br>Storage temperature range -55 °C to100 °C [-67 °F to 212 °F]<br>Soldering terminal temperature/time 315 °C [599 °F] max./10 s max.<br>Vibration 10 G at 20 Hz to 2000 Hz<br>Shock 100 G for 11 ms<br>Life 1 million cycles min.<br>**----- End of picture text -----**<br> **5** sensing.honeywell.com ## Miniature Low Pressure Sensors **Table 3. Performance Characteristics (Vcc =10.00 ±0.01 Vdc; Ta = 25 °C [77 °f])** **==> picture [542 x 280] intentionally omitted <==** **----- Start of picture text -----**<br> operating Pressure range<br>0 psi to 0 psi to 0 psi to 0 psi to 0 psi to 0 psi to 0 psi to<br>Characteristic Unit note<br>0.5 psi 1 psi 5 psi 15 psi 30 psi 100 psi 250 psi<br>Typ. max. Typ. max. Typ. max. Typ. max. Typ. max. Typ. max. Typ. max.<br>35 45 115 225 330 225 212<br>Span – – – – – – – mV 1<br>±10 ±15 ±30 ±60 ±90 ±69 ±68<br>Null offset – 0 ±30 – 0 ±30 – 0 ±30 – 0 ±30 – 0 ±30 – 0 ±30 – 0 ±30 mV 2<br>Linearity (Best<br>Fit Straight Line, ±0.2 ±1.0 ±0.2 ±1.0 ±0.2 ±1.0 ±0.2 ±1.0 ±0.2 ±1.0 ±0.2 ±1.0 ±0.2 ±1.0 %span 3<br>P2>P1)<br>Null shift<br>(0 °C to 25 °C, ±1.0 – ±1.0 – ±1.0 – ±1.0 – ±1.0 – ±1.0 – ±1.0 – mV 4<br>25 °C to 50 °C)<br>Span shift<br>(0 °C to 25 °C, ±5.0 – ±5.0 – ±5.0 – ±5.0 – ±5.0 – ±5.0 – ±5.0 – %span 5<br>25 °C to 50 °C)<br>Repeatability ±0.5 – ±0.5 – ±0.5 – ±0.5 – ±0.5 – ±0.5 – ±0.5 – mV 6<br>and hysteresis<br>Overpressure – 20 – 20 – 20 – 45 – 60 – 200 – 250 psi 7<br>**----- End of picture text -----**<br> 1Span is the algebraic difference between the output signal measured at the upper and lower limits of the operating pressure range, where Port 2 (P2)>Port 1 (P1). 2The output signal obtained when zero pressure is applied to all available ports. 3The maximum deviation of product output from a straight line fitted to the output measured over the specified operating pressure range, calculated according to BFSL. The straight line is fitted along a set of points that minimizes the sum of the square of the deviations of each of the points (“leastsquares” method). 4The maximum deviation in offset due to changes in temperature over the compensated temperature range, relative to offset measured at a reference temperature of 25 °C. 5The maximum deviation in span due to changes in temperature over the compensated temperature range, relative to full-scale span measured at a reference temperature of 25 °C. 6Repeatability is the maximum difference between the output readings when the same pressure is applied consecutively, under the same operating conditions, with pressure approaching from the same direction within the specified operating pressure range. Hysteresis is the maximum difference between output readings when the same pressure is applied consecutively, under the same operating conditions, with pressure approaching from opposite directions within the specified operating pressure range. 7Overpressure is the maximum pressure that may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all available pressure ports at any temperature within the operating temperature range. **figure 1. Circuit Diagram** **==> picture [511 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> Output “A” increases as P2 pressure increases. Symbol Description<br>Output “B” deceases as P2 pressure increases. Vcc supply<br>OUTPUT A bridge positive output<br>PIN 1 PIN 2 PIN 4 GROUND ground<br>VCC OUTPUT OUTPUT<br>A B OUTPUT B bridge negative output<br>PIN 3<br>GROUND<br>**----- End of picture text -----**<br> **6** sensing.honeywell.com ## 24PC Series, Uncompensated/Unamplified ## **figure 2. nomenclature and order Guide[1, 4]** For example, a **24PCBEJ6G** catalog listing defines a 24PC Series Miniature Low Pressure Sensor, Uncompensated/Unamplified, 5 psi pressure range, EPDM seal material, needle pressure port type, 1 x 4 SIP, 15,2 mm [0.60 in] long termination configuration, with normal polarity output and gage pressure measurement type. |**24PC**<br>Product Series|**B**<br>Pressure Range|**B**<br>Pressure Range|**E**<br>Seal Material|**E**<br>Seal Material|**J**<br>Pressure Port Type|**J**<br>Pressure Port Type|**2G**<br>Termination Configuration,<br>Output, Pressure<br>Measurement Type|**2G**<br>Termination Configuration,<br>Output, Pressure<br>Measurement Type| |---|---|---|---|---|---|---|---|---| |**24PC**Series<br>Miniature Low<br>Pressure Sensors,<br>Uncompensated/<br>Unamplified|Pressure Sensors,<br>**A**<br>**B**<br>**C**|1 psi<br>5 psi<br>15 psi|**F**<br>**E**<br>**N**|fluorosilicone<br>EPDM<br>neoprene2|**A**<br>**B**<br>**C**|Straight<br>Barbed<br>Luer|**6A**<br>**6D**|1 x 4 SIP, 15,2 mm [0.60 in] long,<br>normal polarity, absolute3<br>1 x 4 SIP, 15,2 mm [0.60 in] long,<br>normal polarity, differential| ||**D**|30 psi|**S**|silicone|**D**|Modular|**6G**|1 x 4 SIP, 15,2 mm [0.60 in] long,<br>normal polarity, gage| ||**F**<br>**E**|100 psi<br>0.5 psi|||**H**<br>**I**|M5 thread port<br>90° (opposite Pin 1)|**1G**|1 x 4 SIP, 10,2 mm [0.40 in] long,<br>normal polarity, gage| ||**G**|250 psi|||**J**|Needle|**2G**|2 x 2 DIP, normal polarity, gage| ||||||**K**|90° (toward Pin 1)||| ||||||**M**|1/4-28 thread||| ||||||**S**|Manifold mount||| ||||||**T**|Long barbed||| 1Every combination may not be possible. Contact customer service. 2Available in 0.5 psi, 1 psi, 5 psi and 15 psi pressure ranges only. 3Absolute pressure sensors require pressure port types A or D. 4Various wire harnesses with end connector options are available. Contact customer service. **7** sensing.honeywell.com ## Miniature Low Pressure Sensors **Table 4. all available Standard Configurations (See figure 2)** **==> picture [490 x 661] intentionally omitted <==** **----- Start of picture text -----**<br> Termination Configuration, output, Pressure measurement Type<br>6a 6D 6G 1G 2G<br>a<br>N/A<br>Straight<br>b<br>N/A<br>barbed<br>C<br>N/A<br>luer<br>D<br>N/A<br>modular<br>2 7 8<br>H<br>m5 N/A<br>Thread<br>i<br>90°<br>N/A N/A N/A<br>(opposite<br>Pin 1)<br>J<br>N/A N/A<br>needle<br>K<br>90°<br>N/A N/A<br>(Toward<br>Pin 1)<br>m<br>1/4-28 N/A<br>Thread<br>4+ bh bb<br>S<br>manifold N/A<br>mount<br>$a<br>T<br>long N/A N/A<br>barbed<br>Pressure Port Type<br>**----- End of picture text -----**<br> **8** sensing.honeywell.com ## 24PC Series, Uncompensated/Unamplified **figure 3. mounting Dimensions (for reference only: mm/[in].)** **==> picture [542 x 684] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXa6a 24PCXXa6D<br>12,7[0.5] 1,2 DIA.[0.05] 2X 6,4 DIA. [0.25] 12,7[0.5] 2X 1,9 DIA. [0.07]<br>8,0 8,0<br>[0.315] [0.32]<br>4 3 2 1 4 3 2 1 2X 6,4 DIA. [0.25]<br>15,2<br>15,2 [0.60]<br>[0.60]<br>4X 1,0<br>4X 1,0 4X 0,5 [0.04]<br>4X 0,5 [0.04] [0.02] 2,5<br> [0.02] 2,5 [0.10]3X 2,5 [0.10] 2X 5,1 DIA.<br>3X 2,5 [0.10] PORT 2 [0.20]<br> [0.10]<br>PORT 2 21,7<br>[0.85]<br>0,4<br>9,0 [0.02] 2X 4,5<br>[0.35] [0.18]<br>13,4<br>[0.53] 0,4<br>9,0 [0.02]<br>1,7 [0.35]<br>[0.07]<br>21,7<br>[0.85] 1,7<br>34,4 [0.07]<br> 6,4 DIA. [1.35]<br>PORT 1 [0.25]<br>5,0 DIA. PORT 1<br>[0.20]<br>24PCXXa6G 24PCXXa2G<br>12,7<br>[0.5] 1,9 DIA.<br>[0.07]<br>8,0<br>[0.32] 12,7<br>[0.5]<br>4 3 2 1 6,4 DIA. [0.25] 3 4 [0.07] 1,9 DIA.<br>15,2 8,0<br>[0.60] [0.32]<br> 6,4 DIA.<br>2 1 [0.25]<br>PORT 2<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> 2,5 8,9 21,7<br>3X 2,5 [0.10] [0.35] [0.85]<br> [0.10] PORT 2 5,1 DIA. [0.20] 27,8<br>[1.10]<br>21,7<br>[0.85] 9,0<br>[0.35]<br> 4,5<br> [0.18]<br>2,1<br>0,4 [0.08]<br>[0.35]9,0 [0.02] 4X 0,5 4X 1,0 4X 0,4<br> [0.02] [0.04] [0.02]<br>2X 5 2X 8<br>1,7 [0.20] [0.31]<br>[0.07] PORT 1<br>PORT 1<br>**----- End of picture text -----**<br> **9** sensing.honeywell.com ## Miniature Low Pressure Sensors **figure 3. mounting Dimensions (continued)** **==> picture [541 x 683] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXb6D 12,7 24PCXXb6G<br>[0.5]<br>12,7<br> 2,0 DIA.<br>8,0 [0.5] [0.08]<br>[0.32]<br>8,0<br>4 3 2 1 [0.32]<br>15,2 4 3 2 1<br>[0.60]<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> 2,5 4X 1,0<br> [0.10]3X 2,5 PORT 2 [0.10] 3,2 DIA.[0.13] [0.02]4X 0,5 [0.04]<br> 4,7 DIA.[0.19] [0.10]3X 2,5 [0.10] 2,5<br>[0.80]20,4 [0.14]3,6 [0.22]5,6 PORT 2 4,7 DIA. 3,2 DIA.[0.13]<br> 4,1 DIA. [0.19]<br>0,4 [0.16] 20,4 3,6 5,6<br>9,0 [0.02] [0.80] [0.14] [0.22]<br>[0.35] 4,1 DIA.<br>[0.16]<br>0,4<br>33,1 [0.17]4,4 [0.06]1,6 [0.35]9,0 [0.02]<br>[1.30]<br>1,6<br> 6,4 DIA. [0.06]<br>PORT 1 [0.25]<br> 5,0 DIA.<br>[0.20]<br>PORT 1<br>24PCXXb1G 24PCXXb2G<br>12,7<br>[0.5] 2,0 DIA.<br>[0.08]<br>8,0 12,7<br>[0.32] [0.5] 2,0 DIA.<br>3 4 [0.08]<br>4 3 2 1<br>10,2 8,0<br>[0.40] [0.32]<br>2 1 3,2 DIA.<br>4X 1,0<br>4X 0,5 [0.04] PORT 2 [0.13]<br> [0.02]<br>2,5<br>3X 2,5<br> [0.10] PORT 2 [0.10] 3,2 DIA.[0.13] [0.80]20,4 3,6 [0.14] [0.22]5,6<br> 4,7 DIA.<br>26,5<br>[0.19]<br>[1.04]<br>20,4 3,6 5,6<br>[0.80] [0.14] [0.22] 9,0 2,0<br> 4,1 DIA. [0.35] [0.08]<br>[0.16]<br>0,4<br>9,0 [0.02]<br>[0.35] 4X 0,5 4 X 1,0 4X 0,4<br> [0.02] [0.04] [0.02]<br>1,6 2X 5 2X 8<br>[0.06] [0.20] [0.31]<br>PORT 1<br>PORT 1<br>**----- End of picture text -----**<br> **10** sensing.honeywell.com 24PC Series, Uncompensated/Unamplified **figure 3. mounting Dimensions (continued)** **==> picture [542 x 684] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXC6D 12,7 24PCXXC6G<br>[0.5]<br>12,7<br>8,0 [0.5] 1,2 DIA.<br>[0.32] [0.05]<br>8,0<br>4 3 2 1 [0.32]<br>15,2 4 3 2 1<br>[0.60]<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> [0.10]3X 2,5 PORT 2 [0.10] 2,5 4,6 DIA.[0.18] [0.02]4X 0,5 [0.04]4X 1,0<br>[0.15] 3 ,9 DIA. 3X 2,5 [0.10] 2,5 3,9 DIA.<br> [0.10] [0.15]<br>9,7 PORT 2<br>[0.38]<br> 4,6 DIA.<br>31,3<br>[1.23] 0,4 9,7 [0.18]<br>9,0 [0.02] [0.38]<br>[0.35] 18,7<br>[0.74]<br>0,4<br>[0.17]4,4 [0.07]1,7 [0.35]9,0 [0.02]<br> 6,4 DIA. [0.07]1,7<br>[0.25]<br>PORT 1<br> 5,0 DIA.<br>[0.20]<br>PORT 1<br>24PCXXC1G 24PCXXC2G<br>12,7<br>[0.5] 1,2 DIA. 12,7<br>[0.05]<br>[0.5]<br>8,0 3 4 1,2 DIA.<br>[0.05]<br>[0.32]<br>8,0<br>4 3 2 1 [0.32]<br>10,2<br>[0.40] 2 1 3,9 DIA.<br>PORT 2 [0.15]<br>4X 1,0 4,6 DIA.<br>4X 0,5 [0.04] [0.18]<br> [0.02]<br> [0.10]3X 2,5 PORT 2 [0.10] 2,5 3,9 DIA.[0.15] 18,7 [0.38]9,7 [0.98]24,8<br> 4,6 DIA. [0.74]<br>[0.18]<br>9,0<br>9,7 [0.35]<br>[0.38]<br>18,7<br>[0.74]<br>0,4<br>9,0 [0.02]<br>[0.35] 4X 0,5 4 X 1,0 4X 0,4<br> [0.02] [0.04] [0.02]<br>2X 5 2X 8<br>1,7 [0.20] [0.31]<br>[0.07]<br>PORT 1<br>PORT 1<br>**----- End of picture text -----**<br> **11** sensing.honeywell.com ## Miniature Low Pressure Sensors **figure 3. mounting Dimensions (continued)** **24PCXXD6a** **==> picture [192 x 272] intentionally omitted <==** **----- Start of picture text -----**<br> 12,7<br>[0.5] 1,2 DIA.<br>[0.05]<br>8,0<br>[0.32]<br>4 3 2 1<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> 2,5<br>3X 2,5 [0.10]<br> [0.10]<br>PORT 2<br>0,4<br>9,0 [0.02]<br>[0.35]<br>1,7<br>[0.07]<br>PORT 1<br>**----- End of picture text -----**<br> **==> picture [52 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXD6G<br>**----- End of picture text -----**<br> **==> picture [180 x 274] intentionally omitted <==** **----- Start of picture text -----**<br> 12,7 1,2 DIA.<br>[0.5] [0.05]<br>8,0<br>[0.32]<br>4 3 2 1<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> 2,5<br>3X 2,5 [0.10]<br> [0.10]<br>PORT 2<br>0,4<br>9,0 [0.02]<br>[0.35]<br>1,7<br>[0.07]<br>PORT 1<br>**----- End of picture text -----**<br> ## **24PCXXD6D** **==> picture [215 x 326] intentionally omitted <==** **----- Start of picture text -----**<br> 12,7 1,2 DIA.<br>[0.5] [0.05]<br>8,0<br>[0.32]<br>4 3 2 1<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> 2,5<br>3X 2,5 [0.10]<br> [0.10]<br>PORT 2<br>0,4<br>9,0 [0.02]<br>[0.35]<br>4,4 1,7<br>21,7 [0.17] [0.07]<br>[0.85]<br> 6,4 DIA.<br>PORT 1 [0.25]<br> 5,0 DIA.<br>[0.20]<br>**----- End of picture text -----**<br> **==> picture [51 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXD2G<br>**----- End of picture text -----**<br> **==> picture [156 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> 12,7<br>[0.5]<br>3 4 1,2 DIA.<br>[0.05]<br>8,0<br>[0.32]<br>2 1<br>PORT 2<br>9,0 2,0 0,59<br>[0.35] [0.08] [15.1]<br>4X 0,5 4 X 1,0 4X 0,4<br> [0.02] [0.04] [0.02]<br>2X 5 2X 8<br> [0.20] [0.31]<br>PORT 1<br>**----- End of picture text -----**<br> **12** sensing.honeywell.com ## 24PC Series, Uncompensated/Unamplified **figure 3. mounting Dimensions (continued)** **==> picture [542 x 683] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXH6D 12,7 1,2 DIA. 24PCXXH6G<br>[0.5] [0.05]<br>8,0<br>[0.32] 12,7 1,2 DIA.<br>[0.5] [0.05]<br>4 3 2 1<br>8,0<br>15,2 [0.32]<br>[0.60]<br>4 3 2 1<br>10,2<br>4X 1,0 [0.40]<br>4X 0,5 [0.04]<br> [0.02]<br> [0.10]3X 2,5 [0.10] 2,5 4X 0,5 [0.10] 2,5<br>PORT 2 7,3 DIA [0.02] 4X 1,0<br> M5 X 0,8 [0.29] 3X 2,5 [0.04]<br>1,1 [0.10] PORT 2<br>[0.4]<br>3,6 M5 X 0,8<br>[0.4] 1,1<br>21,7 [0.4]<br>[0.85] 0,4 3,6<br>[0.02] [0.4]<br>9,0<br>[0.35] 21,7<br>[0.85] 0,4<br>4,4 1,7 9,0 [0.02]<br>34,4 [0.17] [0.07] [0.35]<br>[1.35]<br> 6,4 DIA<br>[0.25] 1,7<br>PORT 1 [0.20] 5,0 DIA. [0.07]<br>PORT 1<br>24PCXXH1G 24PCXXH2G<br>12,7 1,2 DIA.<br>[0.5] [0.05]<br>8,0 12,7<br>[0.32] [0.5]<br>3 4 1,2 DIA.<br>4 3 2 1 [0.05]<br>8,0<br>15,2 [0.32]<br>[0.60]<br> 7,3 DIA. 2 1<br>[0.29] PORT 2<br>4X 1,0<br>4X 0,5 [0.04] M5 X 0,8<br> [0.02] 1,1<br> [0.10]3X 2,5 PORT 2 [0.10] 2,5 7,3 DIA. [0.4]3,6 [0.4] [1.09]27,8<br>[0.29]<br> M5 X 0,8 21,7<br>1,1 [0.85]<br>[0.4]<br>3,6 9,0<br>[0.4] [0.35]<br>21,7<br>21,7 [0.85]<br>[0.85] 0,4<br>[0.02]<br>9,0<br>[0.35] 4X 0,5 4 X 1,0 4X 0,4<br> [0.02] [0.04] [0.02]<br>2X 5 2X 8<br>[0.07]1,7 [0.20] [0.31]<br>PORT 1<br>PORT 1<br>**----- End of picture text -----**<br> **13** sensing.honeywell.com ## Miniature Low Pressure Sensors **figure 3. mounting Dimensions (continued)** **==> picture [542 x 683] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXi6D 5,1 DIA.[0.20] 24PCXXi6G 5,1 DIA.<br> 6,4 DIA. [0.20]<br>[0.25] 6,4 DIA.<br>[0.25]<br>4,1<br>[0.16] 4,1<br>[0.16]<br>36,2<br>[1.43]<br>8,0 36,2<br>[0.32] [1.43]<br>8,0<br>4 3 2 1 [0.32]<br>15,2 4 3 2 1<br>[0.60]<br>15,2<br>[0.60]<br>2,5<br>4X 0,5 [0.10]<br> [0.02]<br>4X 1,0<br> [0.10]3X 2,5 [0.04] 4X 0,5 [0.10]2,5<br>[0.28]7,0 [0.11]2,9 [0.06]1,6 PORT 2 [0.02]3X 2,5 [0.04]4X 1,0<br> [0.10]<br>1,6 7,0 2,9 1,6 PORT 2<br>14,5 0,4 [0.06] [0.28] [0.11] [0.06]<br>[0.57] 9,0 [0.02]<br>[0.35] 2,0 DIA.[0.08] 1,6<br>14,5 0,4 [0.06]<br>[1.07]27,2 [0.07]1,7 [0.57] [0.35]9,0 [0.02] 2,0 DIA.<br>4,4 [0.08]<br>[0.17]<br>PORT 1 [0.25] 6,4 DIA. [0.07]1,7<br> 5,0 DIA.<br>[0.20]<br>PORT 1<br>24PCXXJ6D 24PCXXJ6G<br>12,7 0,6 DIA.<br>[0.5] [0.02]<br>[0.32]8,0 12,7[0.5] 0,6 DIA.[0.02]<br>8,0<br>4 3 2 1 [0.32]<br>[0.60]15,2 4 3 2 1<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> 2,5<br> [0.10]3X 2,5 [0.10] 1,9 DIA. 4X 0,5 [0.04]4X 1,0<br>PORT 2 [0.07] [0.02]<br> 2,5<br> 6,4 DIA. 3X 2,5 [0.10] 1,9 DIA.<br>[0.25] [0.10] PORT 2 [0.07]<br>22,1 6,4 DIA.<br>[0.87] [0.25]<br>22,1<br>0,4 [0.87]<br>9,0 [0.02]<br>[0.35]<br>0,4<br> 4,4 1,6 9,0 [0.02]<br> [0.17] [0.06] [0.35]<br>34,8<br>[1.37]<br>1,6<br>[0.06]<br> 6,4 DIA.<br>PORT 1 [0.25]<br> 5,0 DIA.<br>[0.20]<br>PORT 1<br>**----- End of picture text -----**<br> **14** sensing.honeywell.com ## 24PC Series, Uncompensated/Unamplified ## **figure 3. mounting Dimensions (continued)** **==> picture [547 x 342] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXJ2G 24PCXXK6D<br>8,0<br>[0.315]<br>21,0<br>[0.83]<br>12,7<br>3 [0.5]4 0,6 DIA.[0.02] [0.60]15,2 [0.16]4,1<br>8,0<br>[0.32]<br>4X 1,0<br>4X 0,5 [0.04]<br>2 1 1,9 DIA. [0.02]<br>PORT 2 [0.07] [0.10]3X 2,5 [0.10] 2,5 6,4 DIA.<br> 6,4 DIA. [0.25]<br>[0.25] [0.28]7,0 [0.11]2,9 5,1 DIA. [0.06]1,6<br>22,1 28,2 PORT 2 [0.20]<br>[0.87] [1.11] 1,6<br>14,5 0,4 [0.06]<br>[0.57] 9,0 [0.02]<br> 2,0 DIA<br>[0.35]<br>[0.08]<br>9,0<br>[0.35]<br>27,2 1,7<br>[1.07] [0.07]<br>4,4<br>[0.17]<br>4X 0,5 4X 1,0 4X 0,4 6,4 DIA.<br> [0.02] [0.04] [0.02] PORT 1 [0.25]<br>2X 5 2X 8 4 3 2 1 5,0 DIA.<br> [0.20] [0.31] [0.20]<br>PORT 1<br>**----- End of picture text -----**<br> **==> picture [542 x 342] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXK6G 24PCXXK2G<br>12,7<br>[0.5]<br>8,0<br>8,0 [0.32]<br>[0.315]<br>21,0<br>[0.83] 4,1<br>4,1 [0.16]<br>[0.16] 13,6<br>15,2 [0.51]<br>[0.60]<br> 6,4 DIA.<br>[0.25]<br> [0.02]4X 0,5 [0.04]4X 1,0 [0.28]7,0 [0.11]2,9 PORT 2 5[0.20] [,1 DIA.] [0.06]1,6<br> 2,5<br> [0.10]3X 2,5 [0.10] 6,4 DIA. 14,5 [0.06]1,6<br>[0.25]<br>[0.28]7,0 [0.11]2,9 PORT 2 [0.20] 5,1 DIA. [0.06]1,6 [0.57] [0.35]9,0<br>1,6 20,6<br>14,5 0,4 [0.06] [0.81]<br>[0.57] [0.35]9,0 2,0 DIA.[0.08] [0.02] 4X 0,5 [0.04]4X 1,0 4X 0,4<br> [0.02]<br> [0.02] 2X 5 2X 8<br>4 3 2 1 [0.07]1,7 [0.20] [0.31]<br> 5,0 DIA.<br>[0.20]<br>PORT 1 6,4 DIA.<br>[0.25]<br>2 1<br>3 4<br>**----- End of picture text -----**<br> **15** sensing.honeywell.com ## Miniature Low Pressure Sensors ## **figure 3. mounting Dimensions (continued)** **==> picture [545 x 683] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXm6D 12,7 24PCXXm6G<br>[0.5] 1,2 DIA.<br>[0.05] 12,7<br>8,0 [0.5] 1,2 DIA.<br>[0.32] [0.05]<br>8,0<br>4 3 2 1 [0.32]<br>15,2 4 3 2 1<br>[0.60]<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> [0.10]3X 2,5 [0.10] 2,5 [0.02]4X 0,5 [0.04]4X 1,0<br>PORT 2 9,1 DIA. 3X 2,5 [0.10] 2,5<br> ¼-28 UNF [0.36] [0.10]<br>1,8 PORT 2 9,1 DIA.<br>[0.07] [0.36]<br>3,6 ¼-28 UNF<br>[0.4] 1,8<br>24,0 [0.13]3,2 7,1 DIA.[0.30] 3,6 [0.07]<br>[0.94] [0.4]<br>9,0 0,4 3,2 7,1 DIA.<br>[0.35] [0.02] 24,0 [0.13] [0.30]<br>[0.94] 0,4<br>4,4 9,0 [0.02]<br>[0.17] 1,7 [0.35]<br>36,7 [0.07]<br>[1.44]<br> 6,4 DIA. 1,7<br>[0.25] [0.07]<br>PORT 1 5,0 DIA.<br>[0.20]<br>PORT 1<br>24PCXXm1G 24PCXXm2G<br>12,7 1,2 DIA.<br>[0.5] [0.05]<br>12,7<br>[0.32]8,0 3 [0.5] 4 1,2 DIA.[0.05]<br>8,0<br>4 3 2 1 [0.32]<br>10,2<br>[0.40] 2 1<br>PORT 2 9,1 DIA.<br> 2,5 [0.36]<br>4X 0,5 [0.10] ¼-28 UNF<br> [0.02] 4X 1,0 24,0 1,8<br>3X 2,5 [0.04] [0.94] 3,6 [0.07]<br> [0.10] PORT 2 [0.4]<br> M5 X 0,8 3,2 7,1 DIA.<br>1,1 [0.13] [0.30]<br>[0.4]<br>3,6<br>9,0<br>[0.4] [0.35]<br>21,7<br>[0.85] 0,4<br>9,0 [0.02]<br>[0.35] 4X 0,5 4X 1,0 4X 0,4<br> [0.02] [0.04] [0.02]<br>[0.07]1,7 [0.20]2X 5 [0.31]2X 8<br>PORT 1<br>PORT 1<br>**----- End of picture text -----**<br> **16** sensing.honeywell.com 24PC Series, Uncompensated/Unamplified **figure 3. mounting Dimensions (continued)** **==> picture [542 x 683] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXX6SD 24PCXXS6G<br>12,7<br>[0.5] 1,2 DIA. 12,7<br>[0.05] [0.5] 1,2 DIA.<br>8,0 [0.05]<br>[0.32]<br>8,0<br>[0.32]<br>4 3 2 1 6,3 DIA.<br>[0.25]<br>4 3 2 1 6,3 DIA.<br>15,2 [0.25]<br>[0.60]<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02] 4X 1,0<br>3X 2,5 [0.10] 2,5 [0.02]4X 0,5 [0.04]<br> [0.10] 2,5<br>PORT 2 9,1 DIA.[0.36] [0.10]3X 2,5 [0.10]<br> 9,1 DIA.<br>PORT 2 [0.36]<br>1,3<br>13,9<br>[0.55] [0.35]9,0 [0.05] [0.02]0,4 [0.05]1,3 [0.55]13,9 0,4<br>9,0 [0.02]<br>[0.35]<br>4,4 1,7<br>26,54 [0.17] [0.07]<br>[1.04] 1,7<br>[0.07]<br> 6,4 DIA.<br>PORT 1 [0.25]<br> 5,0 DIA.<br>[0.20]<br>PORT 1<br>24PCXXS1G 24PCXXS2G<br>12,7<br>[0.5] 1,2 DIA. 12,7[0.5]<br>[0.05] 3 4 1,2 DIA.<br>8,0 [0.05]<br>[0.32] 8,0<br>[0.32]<br>4 3 2 1 6,3 DIA.<br>10,2 [0.25] 2 1 6,3 DIA.<br>[0.40] [0.25]<br>PORT 2 9,1 DIA.<br>[0.36]<br>4X 1,0<br>4X 0,5 [0.04] 13,9 1,3<br> [0.02] 2,5 [0.55] [0.05]<br>3X 2,5 [0.10] 9,1 DIA. 9,0<br> [0.10] [0.36] [0.35]<br>PORT 2 6,3 DIA.<br>1,8 [0.25]<br>[0.07]<br> 5,1 DIA.<br>13,9 [0.20] 4X 0,5 4X 1,0 4X 0,4<br>[0.55] 0,4 [0.02] [0.04] [0.02]<br>9,0 [0.02] 2X 5 2X 8<br>[0.35] [0.20] [0.31]<br>1,7<br>[0.07]<br>PORT 1<br>**----- End of picture text -----**<br> **17** sensing.honeywell.com ## Miniature Low Pressure Sensors **figure 3. mounting Dimensions (continued)** **==> picture [541 x 342] intentionally omitted <==** **----- Start of picture text -----**<br> 24PCXXT6D 12,7 24PCXXT6G<br>[0.5] 12,7<br>[0.5]<br>8,0<br>[0.32]<br>8,0<br>4 3 2 1 [0.32]<br>15,2 4 3 2 1<br>[0.60]<br>15,2<br>[0.60]<br>4X 1,0<br>4X 0,5 [0.04]<br> [0.02]<br> 2,5<br>3X 2,5 [0.10] 4X 1,0<br> [0.10] PORT 2 3,2 DIA. [0.02]4X 0,5 [0.04]<br>[0.13] 2,5<br> 4,7 DIA. 3X 2,5 [0.10]<br>1,8 [0.19] [0.10] PORT 2 3,2 DIA.<br>[1.10]28,0 [0.07] 4,7 DIA. [0.13]<br> 4,1 DIA. [0.19]<br>[0.16] 1,8<br>11,2 [0.07]<br>[0.44] 28,0<br>[1.10]<br>40,7 4,1 DIA.<br>[1.60] 0,4 [0.16]<br>9,0 [0.02] [0.44]11,2<br>[0.35]<br>4,4 1,6 0,4<br>[0.17] [0.06] 9,0 [0.02]<br>[0.35]<br> 6,4 DIA. 1,6<br>PORT 1 [0.25] [0.06]<br> 5,0 DIA.<br>[0.20]<br>PORT 1<br>**----- End of picture text -----**<br> **24PCXXT2G** **==> picture [197 x 268] intentionally omitted <==** **----- Start of picture text -----**<br> 12,7<br>[0.5]<br>3 4<br>8,0<br>[0.32]<br>2 1 1,2 DIA.<br> [0.057]<br>PORT 2 3,2 DIA.<br>[0.13]<br> 4,7 DIA.<br>[0.19]<br>1,8<br>[0.07]<br>28,0<br>[1.10]<br> 4,1 DIA.<br>[0.16]<br>11,2<br>[0.44]<br>9,0<br>[0.35]<br>4X 0,5 4 X 1,0 4X 0,4<br> [0.02] [0.04] [0.02]<br>2X 5 2X 8<br> [0.20] [0.31]<br>PORT 1<br>**----- End of picture text -----**<br> **18** sensing.honeywell.com ## **aDDiTional informaTion** The following associated literature is available at sensing.honeywell.com: ## **warninG PerSonal inJUry** - Product Line Guide - Product Range Guide - Product Installation Instructions - Application-Specific Information - Technical Notes DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. **failure to comply with these instructions could result in death or serious injury.** ## **warninG** ## **miSUSe of DoCUmenTaTion** - The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. - Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. **failure to comply with these instructions could result in death or serious injury.** ## **warranTy/remeDy** ## **Find out more** Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell’s sensing and control products, call **+1-815-235-6847 or 1-800-537-6945** , visit **sensing.honeywell.com,** or e-mail inquiries to Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. **The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. in no event shall Honeywell be liable for consequential, special, or indirect damages.** While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. **info.sc@honeywell.com** Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 **honeywell.com** 32302909-A-EN IL50 February 2015 © 2015 Honeywell International Inc. All rights reserved.
Updated at February 9, 2023
Honeywell is a globally recognized leader in the design and manufacture of advanced sensing and switching solutions. Renowned for engineering components that deliver enhanced precision and ruggedness, Honeywell provides essential technologies for demanding applications across critical healthcare, aerospace, and industrial equipment. With a comprehensive portfolio built to address both basic and complex design challenges, the company stands at the forefront of reliable electronic component manufacturing. The core of our Honeywell offering is an extensive selection of high-performance sensors and transducers. This includes a robust lineup of pressure sensors and transducers engineered for accurate fluid and gas measurement in challenging environments. Furthermore, we provide a wide array of temperature sensors and specialized temperature sensing NTC thermistors designed for stable thermal management, alongside precision current sensors and load cells that deliver critical feedback for control systems. Beyond advanced sensing technology, Honeywell’s expertise extends to essential circuit protection and electromechanical components. Our selection encompasses power relays, thermal magnetic circuit breakers, and standard terminal blocks, ensuring safe and efficient power distribution. Whether integrating core components or sourcing specialized accessories, design engineers can rely on Honeywell for uncompromising quality and operational excellence.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →