ZX1-LD300A81 5M
Sensor, CMOS Laser, PNP, 300 mm, 10 VDC to 30 VDC
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type:
- SVHC: To Be Advised
- Product Range: ZX1 Series
- Sensing Range Max: 300mm
- Sensor Output Type: PNP
- Supply Voltage DC Max: 30V
- Supply Voltage DC Min: 10V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 806.24 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Smart Sensor Laser Sensor with Built-in Amplifier ZX1** ## **A CMOS Laser Sensor That’s Optimum for Simple Measurements** - **A resolution of 0.002 mm that’s suitable for simple measurements.** - **Stable measurements for any type of workpiece.** - **Models available with four different distance specifications.** - **Long-distance model for up to 1,000 mm.** Refer to **Safety Precautions** on page 4. This datasheet contains information only for selecting the appropriate model. Be sure to read the instruction sheet for usage precautions prior to using the product. ## **Ordering Information** **Sensors (Refer to Dimensions on page 5.)** **==> picture [507 x 213] intentionally omitted <==** **----- Start of picture text -----**<br> Model<br>Appearance Connection method Cable length Sensing distance<br>NPN output PNP output<br>2 m ZX1-LD50A61 2M * ZX1-LD50A81 2M *<br>Pre-wired 50 ± 10 mm<br>5 m ZX1-LD50A61 5M ZX1-LD50A81 5M<br>40 60<br>Pre-wired connector 0.5 m ZX1-LD50A66 0.5M ZX1-LD50A86 0.5M<br>|-—____ —_ ——ee<br>2 m ZX1-LD100A61 2M * ZX1-LD100A81 2M *<br>Pre-wired 100 ± 35 mm<br>5 m ZX1-LD100A61 5M ZX1-LD100A81 5M<br>OE [—] 65 135<br>Pre-wired connector a 0.5 m ZX1-LD100A66 0.5M ZX1-LD100A86 0.5M<br>2 m ZX1-LD300A61 2M * ZX1-LD300A81 2M *<br>Pre-wired 300 ± 150 mm<br>5 m ZX1-LD300A61 5M ZX1-LD300A81 5M<br>150 450<br>Pre-wired connector 0.5 m ZX1-LD300A66 0.5M ZX1-LD300A86 0.5M<br>ppeea ——<br>Pre-wired 2 m 600 ± 400 mm ZX1-LD600A61 2M — * ZX1-LD600A81 2M *<br>5 m ZX1-LD600A61 5M ZX1-LD600A81 5M<br>Ff 200 1,000<br>Pre-wired connector 0.5 m ZX1-LD600A66 0.5M ZX1-LD600A86 0.5M<br>ee eee<br>* Sensors with Class 1 lasers are also available.<br>Add an “L” to the end of the model number when ordering. (Example: ZX1-LD50A61L 2M)<br>**----- End of picture text -----**<br> ## **Accessories (sold separately)** **Extension Cables for Pre-wired Connector Models** An Extension Cable is not provided with the Sensor. Order an Extension Cable separately. **(Refer to Dimensions on page 6.)** |**Cable length**|**Model**| |---|---| |10 m|**ZX0-XC10R**| |20 m|**ZX0-XC20R**| **Mounting Brackets** A Mounting Bracket is not provided with the Sensor. Order a Mounting Bracket separately if required. **(Refer to Dimensions on page 6.) Applicable sensors** ~~es~~ **Appearance Model Remarks** Mounting Bracket: 1 ZX1-LD50 @ Nut plate: 1 **E39-L180** ZX1-LD100 @ Phillips screws (M3 × 30): 2 Mounting Bracket: 1 ZX1-LD300 @ Nut plate: 1 **E39-L181** ZX1-LD600 @ Phillips screws ~~Ce~~ (M4 × 35): 2 ~~yt~~ **1** **ZX1** ## **Ratings and Specifications** |**Model**|**Model**|**NPN output**|**ZX1-LD50A61**<br>**ZX1-LD50A66**|**ZX1-LD100A61**<br>**ZX1-LD100A66**|**ZX1-LD300A61**<br>**ZX1-LD300A66**|**ZX1-LD600A61**<br>**ZX1-LD600A66**| |---|---|---|---|---|---|---| |**Item**||**PNP output**|**ZX1-LD50A81**<br>**ZX1-LD50A86**|**ZX1-LD100A81**<br>**ZX1-LD100A86**|**ZX1-LD300A81**<br>**ZX1-LD300A86**|**ZX1-LD600A81**<br>**ZX1-LD600A86**| |**Measurement range**|||50 ± 10 mm|100 ± 35 mm|300 ± 150 mm|600 ± 400 mm| |**Light source (wave length)**|||Visible-light semiconductor laser<br>(wavelength: 660 nm, 1 mW max., IEC/EN Class 2, FDA Class 2*1)|||| |**Spot diameter (typical)**<br>**(Defined at the measurement center dis-**<br>**tance)** ***2**|||0.17 mm dia.|0.33 mm dia.|0.52 mm dia.|0.56 mm dia.| |**Power consumption**|||2,500 mW max. (105 mA max. at 24 VDC, 210 mA max. at 12 VDC)|||| |**Current consumption**|||250 mA max. (at power supply voltage 10 VDC)|||| |**Control output**|||Load power supply voltage: 30 VDC max., Load current: 100 mA max.<br>(Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to<br>100 mA))|||| |**Analog output**|||Current output: 4 to 20 mA, maximum load resistance: 300Ω<br>(The output is 20 mA for the nearest point in the measurement range in respect to the Sen-<br>sor and 4 mA for the farthest point.)|||| |**Functions**|||Smart tuning, keep function, scaling setting, background removal, OFF-delay timer, ON-delay<br>timer, one-shot timer, ON/OFF-delay timer, zero reset, area output, eco function, hysteresis<br>width setting, and setting initialization|||| |**Indicators**|||Digital display (red), output indicator (OUT1, OUT2) (orange), zero reset indicator (or-<br>ange), menu indicator (orange), laser ON indicator (green), and smart tuning indicator<br>(blue)|||| |**Response time**|**Judgment output**||Super-high-speed (SHS) Mode: 1 ms<br>High-speed (HS) Mode: 10 ms<br>Standard (Stnd) Mode : 100 ms|||| ||**Laser OFF input**||200 ms max.|||| ||**Zero reset input**||200 ms max.|||| |**Temperature characteristic** ***3**|||0.03% F.S./°C|||0.04% F.S./°C| |**Linearity** ***4**|||±0.15% F.S.||±0.25% F.S.|±0.25% F.S.<br>(200 to 600 mm)<br>±0.5% F.S.<br>(entire range)| |**Resolution** ***5**|||2μm|7μm|30μm|80μm| |**Ambient illumination**|||Illumination on received light surface:<br>7,500 lx or less (incandescent light)||Illumination on received light surface:<br>5,000 lx or less (incandescent light)|| |**Ambient temperature**|||Operating: -10 to +55°C, Storage: -15 to +70°C (with no icing or condensation)|||| |**Ambient humidity**|||Operating and storage: 35% to 85% (with no condensation)|||| |**Dielectric strength**|||1,000 VAC, 50/60 Hz, 1 minute|||| |**Vibration resistance (destruction)**|||10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions|||| |**Shock resistance (destruction)**|||500 m/s23 times each in X, Y, and Z directions|||| |**Degree of protection** ***6**|||IEC 60529, IP67|||| |**Connection method**|***7**||Pre-wired model (Standard cable length: 2 m, 5 m)<br>Pre-wired connector model (Standard cable length: 0.5 m)|||| |**Weight**<br>**(packed state/**<br>**sensor only)**|**Pre-wired models**<br>**(2 m)**||Approx. 240 g / Approx. 180 g||Approx. 270 g / Approx. 210 g|| ||**Pre-wired models**<br>**(5 m)**||Approx. 450 g / Approx. 330 g||Approx. 480 g / Approx. 360 g|| ||**Pre-wired connec-**<br>**tor models (0.5 m)**||Approx. 170 g / Approx. 110 g||Approx. 200 g / Approx. 140 g|| |**Materials**|||Case and cover: PBT (polybutylene terephthalate), Optical window: Glass, Cable: PVC,<br>Mounting hole part: SUS303|||| |**Accessories**|||Instruction sheet and Laser warning label (English)|||| - **Note: 1.** False detection outside the measurement range can occur in the case of an object with high reflectance. **2. Refer to the next page for the ratings and specifications of Sensors with Class 1 lasers.** - *1. Classified as Class 2 by IEC60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50. CDRH registration has been completed. (Center for Devices and Radiological Health) (Accession Number: 1210041) - *2. Spot diameter: Defined as 1/e[2] (13.5%) of the central intensity at the measurement center distance. - False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object. Accurate measurements may not be possible for workpieces that are smaller than the spot diameter. - *3. Temperature characteristic: Value for the case the space between the sensor and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance) - *4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object (white ceramic) at a temperature of 25 °C. Linearity and measured value may vary depending on target object. - *5. Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart Tuning. The resolution indicates the repetition accuracy for a still workpiece. Not an indication of the distance accuracy. Resolution performance may not be satisfied in a strong electromagnetic field. - *6. IP67 protection applies to the connector on pre-wired connector models if an extension cable is connected. - *7. Use a Pre-wired Connector Model together with an Extension Cable (10 m or 20 m). **2** **ZX1** ## **Ratings and Specifications of Sensors with Class 1 lasers (ZX1-LD @ L)** The ratings and specifications that are different from those of the Sensors with Class 2 lasers are given below. |Model<br>Item|ZX1-LD50A61L/ZX1-LD50A81L<br>ZX1-LD100A61L/ZX1-LD100A81L|ZX1-LD300A61L/ZX1-LD300A81L<br>ZX1-LD600A61L/ZX1-LD600A81L| |---|---|---| |FDA Class|Class1 0.24mW max.|| |IEC/EN Class|Class1 0.24mW max.|| |Functions|No scaling setting, no hysteresis width setting|| |Ambient illumination|Illumination on received light surface 5,000 lx or less (incandescent light|)<br>Illumination on received light surface 2,500 lx or less (incandescent light)| |Connection method|Pre-wired model (2 m)|| |Accessories|Instruction sheet and Explanatory label (English), FDA certification label|| Accession Number: 1210041 ## **Engineering Data (Typical)** **==> picture [489 x 490] intentionally omitted <==** **----- Start of picture text -----**<br> Angle Characteristic<br>ZX1-LD50 @ ZX1-LD100 @ ZX1-LD300 @ ZX1-LD600 @<br>Side-to-side Inclination Side-to-side Inclination Side-to-side Inclination Side-to-side Inclination<br>3 3 3 3<br>White ceramic White ceramic White ceramic White ceramic<br>SUS304, mirror finish SUS304, mirror finish SUS304, mirror finish SUS304, mirror finish<br>2 Measurement Black rubber 2 Measurement Black rubber 2 Measurement Black rubber 2 Measurement Black rubber<br>center distance center distance center distance center distance<br>+ Inclination + Inclination + Inclination + Inclination<br>1 − Inclination 1 − Inclination 1 − Inclination 1 − Inclination<br>0 0 0 0<br>–1 –1 –1 –1<br>–2 –2 –2 –2<br>–3 –3 –3 –3<br>–50 –40 –30 –20 –10 0 10 20 30 40 50 –50 –40 –30 –20 –10 0 10 20 30 40 50 –50 –40 –30 –20 –10 0 10 20 30 40 50 –50 –40 –30 –20 –10 0 10 20 30 40 50<br>Angle of Inclination (°) Angle of Inclination (°) Angle of Inclination (°) Angle of Inclination (°)<br>ZX1-LD50 @ ZX1-LD100 @ ZX1-LD300 @ ZX1-LD600 @<br>Front-to-back Inclination Front-to-back Inclination Front-to-back Inclination Front-to-back Inclination<br>3 3 3 3<br>White ceramic White ceramic White ceramic White ceramic<br>2 Measurement center distance SUS304, mirror finish Black rubber 2 Measurement center distance SUS304, mirror finish Black rubber 2 Measurement center distance SUS304, mirror finish Black rubber 2 Measurement center distance SUS304, mirror finish Black rubber<br>+ Inclination + Inclination + Inclination + Inclination<br>− Inclination − Inclination − Inclination − Inclination<br>1 1 1 1<br>0 0 0 0<br>–1 –1 –1 –1<br>–2 –2 –2 –2<br>–3 –3 –3 –3<br>–50 –40 –30 –20 –10 0 10 20 30 40 50 –50 –40 –30 –20 –10 0 10 20 30 40 50 –50 –40 –30 –20 –10 0 10 20 30 40 50 –50 –40 –30 –20 –10 0 10 20 30 40 50<br>Angle of Inclination (°) Angle of Inclination (°) Angle of Inclination (°) Angle of Inclination (°)<br>Linearity Characteristic for Different Materials<br>ZX1-LD50 @ ZX1-LD100 @ ZX1-LD300 @ ZX1-LD600 @<br>2.0 2.0 2.0 2.0<br>White ceramic White ceramic White ceramic White ceramic<br>1.5 SUS304, mirror finish 1.5 SUS304, mirror finish 1.5 SUS304, mirror finish 1.5 SUS304, mirror finish<br>Substrate Substrate Substrate Substrate<br>1.0 1.0 1.0 1.0<br>0.5 0.5 0.5 0.5<br>0.0 0.0 0.0 0.0<br>–0.5 –0.5 –0.5 –0.5<br>–1.0 –1.0 –1.0 –1.0<br>–1.5 –1.5 –1.5 –1.5<br>–2.0–10 –8 –6 –4 –2 0 2 4 6 8 10 –2.0–35 –25 –15 –5 0 5 15 25 35 –2.0–150 –100 –50 0 50 100 150 –2.0–400 –300 –200 –100 0 100 200 300 400<br>FAR side NEAR side FAR side NEAR side FAR side NEAR side FAR side NEAR side<br>Measurement Displacement Measurement Displacement Measurement Displacement Measurement Displacement<br>center distance (mm) center distance (mm) center distance (mm) center distance (mm)<br>Measurement diagram<br>Displacement (mm)<br>Sensor<br>Workpiece<br>FAR side NEAR side<br>Measurement<br>center distance<br>Error (%F.S.) Error (%F.S.) Error (%F.S.) Error (%F.S.)<br>Error (%F.S.) Error (%F.S.) Error (%F.S.) Error (%F.S.)<br>Error (%F.S.) Error (%F.S.) Error (%F.S.) Error (%F.S.)<br>**----- End of picture text -----**<br> **Note: 1.** Measurement conditions for the ZX1-LD @@ : Ambient temperature of 25°C in Standard Mode after executing Smart Tuning. **2.** The ambient conditions or workpiece may adversely affect the engineering data of the ZX1-LD @ L. **3.** The X-axis displacement indicates the measurement distance displayed on a digital display. The measurement distance displayed on a digital display takes the measurement center distance as 0 and displays the near side of the Sensor as positive and the far side as negative. **3** **ZX1** ## **I/O Circuit Diagrams** **NPN Output Model (Negative Common) ZX1-LD50A61(L) /ZX1-LD50A66 ZX1-LD100A61(L) /ZX1-LD100A66 ZX1-LD300A61(L) /ZX1-LD300A66 ZX1-LD600A61(L) /ZX1-LD600A66** **PNP Output Model (Positive Common) ZX1-LD50A81(L) /ZX1-LD50A86 ZX1-LD100A81(L) /ZX1-LD100A86 ZX1-LD300A81(L) /ZX1-LD300A86 ZX1-LD600A81(L) /ZX1-LD600A86** **==> picture [512 x 271] intentionally omitted <==** **----- Start of picture text -----**<br> Brown: 10 to 30 VDC Brown: 10 to 30 VDC<br>Load<br>White: OUT1 White: OUT1<br>judgment output Load 10 to 30 VDC judgment output<br>Green: OUT2 Green: OUT2<br>judgment output judgment output Load 10 to 30 VDC<br>Load<br>Blue: GND (0 V) Blue: GND (0 V)<br>∗ 1, ∗ 2 ∗ 1, ∗ 2<br>Orange: TUNE1 input Orange: TUNE1 input<br>∗ 1, ∗ 2 ∗ 1, ∗ 2<br>Pink: TUNE2 input Pink: TUNE2 input<br>∗ 2 ∗ 2<br>Purple: Zero reset input Purple: Zero reset input<br>∗ 1, ∗ 2 ∗ 1, ∗ 2<br>Red: LD-OFF input Red: LD-OFF input<br>Current output Current output<br>4 to 20 mA Black: Analog output 4 to 20 mA Black: Analog output<br>Load 300 Ω max. Load 300 Ω max.<br>Shield: Analog GND Shield: Analog GND<br>*1. TUNE1 input: tuning external input for channel 1<br>TUNE2 input: tuning external input for channel 2<br>LD-OFF input: Laser OFF input<br>*2. The input specification is as follows:<br>NPN Output Model PNP Output Model<br>ON Short-circuited with 0-V terminal or 1.5 V max. Supply voltage short-circuited or supply voltage within -1.5 V<br>OFF Open (leakage current: 0.1 mA max.) Open (leakage current: 0.1 mA max.)<br>itsInternal circu itsInternal circu<br>**----- End of picture text -----**<br> ## **Timing Charts** ## **Safety Precautions** **TUNE1 Input / TUNE2 Input (1) Time identification tuning type** **==> picture [251 x 242] intentionally omitted <==** **----- Start of picture text -----**<br> Set time within 3 s<br>ON<br>TUNE<br>input OFF<br>Tuning completion<br>(2) Tuning type other than time identification<br>4 ms or<br>more within 3 s<br>ON<br>TUNE<br>input<br>OFF<br>Signal Tuning<br>reception completion<br>Zero Reset Input<br>Execution Cancellation<br>4 ms or<br>more within 196 ms 3 s<br>ON<br>Zero reset<br>input OFF<br>Signal Zero reset Zero reset<br>reception execution cancellation<br>Effective zero reset period<br>**----- End of picture text -----**<br> **This datasheet contains information only for selecting the appropriate model.** **Be sure to read the Instruction Sheet for usage precautions prior to using the product.** ## **Laser Safety WARNING** **ZX1-LD** @@@ **: Class 2, ZX1-LD** @@@ **L: Class1** **Do not expose your eyes to the laser radiation either directly or indirectly (i.e., after reflection from a mirror or shiny surface).** **The laser radiation has a high power density and exposure may result in loss of sight.** **Do not disassemble the product. Doing so may cause the laser beam to leak, resulting in the danger of visual impairment.** **Note:** For Precautions for safe use and Precautions for correct use, refer to the Instruction Sheet supplied with the product. ## **LD-OFF Input** **==> picture [218 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> Laser emission ON → OFF Laser emission OFF → ON<br>4 ms or<br>more within 6 ms within 200 ms<br>ON<br>LD-OFF<br>input<br>OFF<br>Signal Laser emission Laser emission<br>reception OFF ON<br>**----- End of picture text -----**<br> **4** **ZX1 (Unit: mm) Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.** **Dimensions** ## **Sensors** **==> picture [450 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> Pre-wired Models Pre-wired Connector Models<br>ZX1-LD50A61(L) ZX1-LD50A66<br>ZX1-LD50A81(L) ZX1-LD50A86<br>ZX1-LD100A61(L) ZX1-LD100A66<br>ZX1-LD100A81(L) ZX1-LD100A86<br>Reference surface Emitter center position mark<br>(10.5)<br>Emitter axis<br>Reference surface Two, 3.2 dia Mounting hole dimensions<br>10.5 24.1 35.3 47 (mo(2) 3.2 unting holes) Reference surface 2.4 18.7 2.5 Reference surface P=0.5 2-M3 3.2 [±0.1 ]<br>14.23 15.1<br>Receiver axis Reference<br>42.3 16.7 Emitter 46.1 52.5 37.8 surface 49.3 [±0.1 ]<br>axis A *<br>7<br>Emitter (10.2)<br>10.1 center L * 11.7 23.635.3 [±0.1 ][±0.1 ]<br>(Measurement<br>center distance)<br>Emitter center position mark Vinyl insulated round robot cable, 6.5 dia., 9 conductors (Conductor cross section:<br>0.125 mm², Insulator diameter: 0.7 mm)<br>* ZX1-LD50: L = 50, A = 21° Standard length: 2 m / 5 m (pre-wired model), 0.5 m (pre-wired connector model)<br>Minimum bending radius: 39 mm<br>**----- End of picture text -----**<br> ZX1-LD100: L = 100, A = 11.5° **Pre-wired Models Pre-wired Connector Models ZX1-LD300A61(L) ZX1-LD300A66 ZX1-LD300A81(L) ZX1-LD300A86 ZX1-LD600A61(L) ZX1-LD600A66 ZX1-LD600A81(L) ZX1-LD600A86** **==> picture [465 x 216] intentionally omitted <==** **----- Start of picture text -----**<br> Reference surface Emitter center position mark<br>(13.6)<br>Emitter axis<br>Reference surface Two, 4.5 dia<br>(mounting holes) Mounting hole dimensions<br>27.2 50.1 4.5 Reference surface Reference 2-M4<br>13.6 45.6 (1.9) 3 21.3 3 surface P=0.7 4.5 [±0.1 ]<br>10.7 17<br>Receiver axis<br>22 Reference<br>55.8 50.3 surface<br>57 66 61.5 [±0.1 ]<br>Emitter<br>axis<br>A *<br>7<br>Emitter (10.2)<br>center L * 30.1 [±0.1 ]<br>10.1 center distance) (Measurement 15.5 45.6 [±0.1 ]<br>Emitter center position mark<br>* ZX1-LD300: L = 300, A = 6.6° V0.125 mm², Insinyl insulated roulator diameter: 0.7 mm)und robot cable, 6.5 dia., 9 conductors (Conductor cross section:<br> ZX1-LD600: L = 600, A = 3.4° Standard length: 2 m / 5 m (pre-wired model), 0.5 m (pre-wired connector model)<br>Minimum bending radius: 39 mm<br>**----- End of picture text -----**<br> ## **Display, Indicators, and Controls** ## **Pre-wired connector** **==> picture [459 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> [MENU] Menu indicator (orange) [LD ON] Laser ON indicator (green)<br>[ZERO] Zero reset indicator (orange) [ST] Smart tuning indicator (blue)<br>OUT1 output indicator (orange) TUNE Button 15.5 dia.<br>39.8<br>OUT2 output indicator (orange)<br>Up Button MODE Button<br>Digital display DOWN Button<br>**----- End of picture text -----**<br> **5** **ZX1** ## **Accessories (sold separately)** **Extension Cables for Pre-wired Connector Models ZX0-XC10R (10 m) ZX0-XC20R (20 m)** **==> picture [508 x 357] intentionally omitted <==** **----- Start of picture text -----**<br> L [* ]<br>15 dia. a =<br>Vinyl insulated round robot cable, 6.5 dia. Shield<br>37.3 Minimum bending radius: 39 mm 90<br>Bending start position: 40 mm<br>* Cable length (L) is as follows.<br> ZX0-XC10R: 10 m, ZX0-XC20R: 20 m<br>Mounting Bracket for ZX1-LD50 @ /ZX1-LD100 @ Mounting Bracket for ZX1-LD300 @ /ZX1-LD600 @<br>E39-L180 E39-L181<br>Nut plate Nut plate<br>Mounting Bracket 2-M3 Mounting Bracket P=0.72-M4<br>41.3 P=0.5 52<br>2-R2 32.1 4.8 2-R2 42.4 6.2<br>= 11.7 Rf | = 15.5 |<br>3.5 dia. 47.6 53.6 4.5 dia. 59.1 67.1<br>46.1 62<br>57 76<br>6 8<br>Material : Stainless steel Material : Stainless steel<br>20<br> (SUS304) (SUS304)<br>Thickness : 1.5 mm 22 Thickness : 2.0 mm<br>12<br>10 3.5 Material : Stainless steel (SUS304) 12 12 Material Thickness : 2.0 mm: Stainless steel (SUS304)<br>14.3.58 Thickness Accessories : T: 2.0 mmwo phillips screws 4.5 4.5 Accessories : T (M4×35, P = 0.7, Stainless steel) wo phillips screws<br>19.75 ~ 18.5 (M3×30, P = 0.5, Stainless steel) and one nut plate 25.9519.1 =i 23 and one nut plate<br>Installation Method (ZX1-LD50 @ /ZX1-LD100 @ ) Installation Method (ZX1-LD300 @ /ZX1-LD600 @ )<br>Using E39-L180 Mounting Bracket Using E39-L181 Mounting Bracket<br>4°<br>8° 3.5°<br>5.5°<br>**----- End of picture text -----**<br> **==> picture [418 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> 18 22.3<br>22.5<br>45.6 25.6 51.2<br>Nut plate Nut plate<br>Reference<br>surface 62 Reference<br>surface 76<br>37.8<br>18.1 52.6<br>7.9<br>18.5<br>3.2 4.4 8.3<br>Mounting Bracket<br>41.3 3.2<br>Mounting Bracket 55.2<br>**----- End of picture text -----**<br> **6** ~~i~~ ## **READ AND UNDERSTAND THIS DOCUMENT** Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. ## **WARRANTY** OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ## **LIMITATIONS OF LIABILITY** OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. ## **SUITABILITY FOR USE** THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: - Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. - Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. - Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ## **PERFORMANCE DATA** Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ## **CHANGE IN SPECIFICATIONS** Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. ## **DIMENSIONS AND WEIGHTS** Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ## **ERRORS AND OMISSIONS** The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. ## **PROGRAMMABLE PRODUCTS** OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. ## **COPYRIGHT AND COPY PERMISSION** This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety. ## **ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.** To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. ## **OMRON Corporation Industrial Automation Company** **Authorized Distributor:** ## **Tokyo, JAPAN** **Contact: www.ia.omron.com** ## _**Regional Headquarters**_ **OMRON ELECTRONICS LLC** One Commerce Drive Schaumburg, ve Schaumburg, e Schaumburg, umburg, mburg, burg, rg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-778847-843-7900/Fax: (1) 847-843-77847-843-7900/Fax: (1) 847-843-778843-7900/Fax: (1) 847-843-77843-7900/Fax: (1) 847-843-778847-843-77847-843-778843-77843-77887 **OMRON EUROPE B.V. OMRON ELECTRONICS LLC Sensor Business Unit** One Commerce Drive Schaumburg, ve Schaumburg, e Schaumburg, umburg, mburg, burg, rg, Carl-Benz-Str. 4, D-71154 Nufringen, Germany IL 60173-5302 U.S.A. Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 Tel: (1) 847-843-7900/Fax: (1) 847-843-778847-843-7900/Fax: (1) 847-843-77847-843-7900/Fax: (1) 847-843-778843-7900/Fax: (1) 847-843-77843-7900/Fax: (1) 847-843-778847-843-77847-843-778843-77843-77887 **OMRON ASIA PACIFIC PTE. LTD. OMRON (CHINA) CO., LTD.** © OMRON Corporation 2011 All Rights Reserved. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Room 2211, Bank of China Tower, In the interest of product improvement, Alexandra Technopark, 200 Yin Cheng Zhong Road, specifications are subject to change without notice. Singapore 119967 PuDong New Area, Shanghai, 200120, China **CSM_4_1_1219** Printed in Japan Tel: (65) 6835-3011/Fax: (65) 6835-2711 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 **Cat. No. E416-E1-02** 0112(1111)
Updated at April 23, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →