ZX-TDA41 2M
Smart Sensor Amplifier Unit, ZX Series Smart Sensors, PNP
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1284.99 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Smart Sensors (High-precision Contact Type) ZX Series (ZX-T)** For the most recent information on models that have been certified for safety standards, refer to your OMRON website. ## **Orderin Information g** ## ■ **Sensors** ## **Sensor Heads** |**Size**|**Type**|**Sensing distance**|**Resolution (See note.)**|**Model**| |---|---|---|---|---| |6 dia.|Short type|1 mm|0.1μm|ZX-TDS01T| ||Standard type|4 mm||ZX-TDS04T| ||Low measurement type|||ZX-TDS04T-L| |8 dia.|Standard type|10 mm|0.4μm|ZX-TDS10T| ||Ultra-low-load Type|||ZX-TDS10T-L| ||Air Lift Type|||ZX-TDS10T-V| ||Air Lift/Air Push Type|||ZX-TDS10T-VL| **Note:** The resolution refers to the minimum value that can be read when a ZX-TDA@1 Amplifier Unit is connected. ## ■ **Amplifier Units** |**Appearance**<br>~~eG~~|**Power supply**<br>~~eG~~|**Output type**<br>~~eG~~|**Model**<br>~~eG~~| |---|---|---|---| ||DC|NPN<br>~~|~~|ZX-TDA11 2M<br>~~|~~| |||PNP<br>~~|~~|ZX-TDA41 2M<br>~~|~~| ## ■ **Accessories (Order Separately)** ## **Calculating Unit** **ZX-series Communications Interface Unit** **==> picture [455 x 92] intentionally omitted <==** **----- Start of picture text -----**<br> Appearance Model Appearance Model<br>ZX-CAL2 ZX-SF11<br>pp<br>**----- End of picture text -----**<br> **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 1 **SmartMonitor Sensor Setup Tool for Cables with Connectors on Both Ends (for Personal Computer Connection Extension)* Appearance Name Model Cable length Model Quantity** ZX-series CommuniZX-SF11 1 m ZX-XC1A 1 cations Interface 4 m ZX-XC4A Unit 8 m ZX-XC8A * Robot Cable models are also available. The model numbers are ZX-XC@R. ~~a~~ ZX-series Communi-cations Interface ZX-SFW11EV3*1, *2 **Preamplifier Mounting Brackets** Unit + ZX-series **Appearance Model Remarks** Sensor Setup Soft+ ware Basic ZX-XBT1 Attached to each CD-ROM Sensor Head CD-ROM ZX-series Sensor ZX-SW11EV3 ~~a~~ Setup Software *1 ZX-XBT2 For DIN track mount*1. When using the ZX-TDA11/41 with the SmartMonitor, either the ing ZX-SFW11EV3 or the ZX-SW11EV3 SmartMonitor must be used. Earlier versions cannot be used. - *2. The ZX-SFW11EV3 SmartMonitor can be used only to set functions and monitor waveforms. ## **S ecifications p** ## ■ **Amplifier Units** |**Item**|**ZX-TDA11**|**ZX-TDA41**| |---|---|---| |**Measurement period**|1 ms|| |**Possible average count set-**<br>**tings (See note 1.)**|1, 16, 32, 64, 128, 256, 512, or 1,024|| |**Linear output (See note 2.)**|Current output: 4 to 20 mA/F.S., Max. load resistance: 300Ω<br>Voltage output:±4 V (±5 V, 1 to 5 V (See note 3.)), Output impedance: 100Ω|| |**Judgement outputs**<br>**(3 outputs: HIGH/PASS/**<br>**LOW)**|NPN open-collector outputs, 30 VDC, 30 mA max.<br>Residual voltage: 1.2 V max.|PNP open-collector outputs, 30 VDC, 30 mA max.<br>Residual voltage: 2 V max.| |**Zero reset input, timing in-**<br>**put, reset input, judgement**<br>**output hold input**|ON: Short-circuited with 0-V terminal or 1.5 V or less<br>OFF: Open (leakage current: 0.1 mA max.)|ON: Supply voltage short-circuited or supply voltage of<br>1.5 V or less<br>OFF: Open (leakage current: 0.1 mA max.)| |**Function**|- Measurement value display<br>- Present value/set value/output value display<br>- Display reverse<br>- ECO mode<br>- Number of display digit changes<br>- Sample hold<br>- Peak hold<br>- Bottom hold, peak-to-peak hold<br>- Self-peak hold<br>- Self-bottom hold<br>- Zero reset<br>- Initial reset<br>- Direct threshold value setting<br>- Position teaching<br>- Hysteresis width setting<br>- Timing inputs<br>- Reset input<br>- Judgement output hold input<br>- (A-B) calculations (See note 4.)<br>- (A+B) calculations (See note 4.)<br>- Sensor disconnection detection - Zero reset memory<br>- Function lock<br>- Non-measurement setting<br>- Clamp value setting<br>- Scale inversion<br>- Zero reset indicator<br>- Span adjustment<br>- Warming-up display<br>- Pressingforce alarm|| |**Indicators**|Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), 7-segment<br>sub-digital display(yellow), power ON (green), zero reset (green), enable (green)|| |**Power supply voltage**|12 to 24 VDC±10%, Ripple (p-p): 10% max.|| |**Current consumption**|140 mA max. (with Sensor connected), For 24-VDC power supplyvoltage: 140 mA max. (with Sensor connected)|| |**Ambient temperature**|Operatingand storage: 0 to 50°C (with no icingor condensation)|| |**Temperature characteristic**|0.03% F.S./°C|| |**Connection method**|Prewired (standard cable length: 2 m)|| |**Weight (packed state)**|Approx. 350g|| |**Materials**|Case: PBT (polybutylene terephthalate), Cover: Polycarbonate|| - **Note 1.** The response speed of the linear output is calculated as the measurement period × (average count setting + 1). The response speed of the judgement outputs is calculated as the measurement period × (average count setting + 1). **2.** The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit. **3.** Setting is possible via the monitor focus function. **4.** A Calculating Unit (ZX-CAL2) is required. **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 2 ## ■ **Sensor Heads** |**Item**|**Item**|**ZX-TDS01T**|**ZX-TDS04T**|**ZX-TDS04T-L**| |---|---|---|---|---| |**Measurement range**||1 mm|4 mm|| |**Maximum actuator travel distance**||Approx. 1.5 mm|Approx. 5 mm|| |**Resolution (See note 1.)**||0.1μm||| |**Linearity (See note 2.)**||0.3% F.S.||| |**Operating force (See note 3.)**||Approx. 0.7 N||Approx. 0.25 N| |**Degree of protection (Sensor Head)**||IEC60529, IP67||IEC60529, IP54| |**Mechanical durability**||10,000,000 operations min.||| |**Ambient temperature**||Operating:<br>0°C to 50°C (with no icing or condensation)<br>Storage:<br>−15°C to 60°C (with no icingor condensation)||| |**Ambient humidity**||Operatingand storage: 35% to 85% (with no icingor condensation)||| |**Temperature char-**<br>**acteristic (See**<br>**note 4.)**|**Sensor Head**|0.03% F.S./°C||| ||**Preamplifier**|0.01% F.S./°C||| |**Weight (packed state)**||Approx. 100g||| |**Materials**|**Sensor Head**|Stainless steel||| ||**Preamplifier**|Polycarbonate||| |**Accessories**||Instruction manual, Preamplifier MountingBrackets (ZX-XBT1)||| - **Note 1.** The resolution is given as the minimum value that can be read when a ZX-TDA@1 Amplifier Unit is connected. This value is taken 15 minutes after turning ON the power with the average number of operations set to 256. **2.** The linearity is given as the error in an ideal straight line displacement output. **3.** These figures are representative values that apply for the measurement mid-point, and are for when the provided actuator is used, with the actuator moving downwards. If the actuator moves horizontally or upwards, the operating force will be reduced. Also, if an actuator other than the standard one is used, the operating force will vary with the weight of the actuator itself. **4.** These figures are representative values that apply for the mid-point of the measurement range. ## ■ **Sensor (Long-range Type)** |**Item**|**Item**|**ZX-TDS10T**|**ZX-TDS10T-V**|**ZX-TDS10T-L**|**ZX-TDS10T-VL**| |---|---|---|---|---|---| |**Vacuum retract (VR) and air push (AP)**<br>**compatible**||No|VR|No|VR/AP| |**Measurement range**||10 mm|||| |**Maximum actuator travel distance**||10.5 mm|||| |**Resolution (See notes 1 and 5.)**||0.4μm|||| |**Linearity (See notes 2 and 5.)**||±0.5% F.S.|||| |**Operating force (See note 3.)**||Approx. 0.7 N|Approx. 0.6 N|Approx. 0.065 N|Approx. 0.09 to 1.41 N| |**Air pressure**|**Vacuum retracting**|---|−0.55 to−0.70 (bar)|---|−0.22 to−0.5 (bar)| ||**Air push**||---||0.125 to 2 (bar)| |**Degree of**<br>**protection**|**Sensor Head**|IP65||IP50|| ||**Preamplifier**|IP40|||| |**Mechanical durability**||10,000,000 operations min.|||| |**Ambient temperature**||Operating: 0 to 50°C (with no icing or condensation), Storage:−10 to 60°C (with no|||icing or condensation)| |**Ambient humidity**||Operatingand storage: 35% to 85% (with no icingor condensation)|||| |**Temperature**<br>**characteristic**<br>**(See note 4.)**|**Sensor Head**|±0.01% F.S./°C|||| ||**Preamplifier**|±0.01% F.S./°C|||| |**Vibration resistance**||0.35-mm single amplitude at 10 to 55 Hz for 50 min each in the X, Y, and Z directions|||| |**Shock resistance**||150 m/S23 times each in 6 directions (up/down, left/right, and forward/backward)|||| |**Connection method**||Prewired connector (2 m from the Sensor Head to the Preamplifier, 0.2 m from the Preamplifier to the connector)|||| |**Weight (packed state)**||Approx. 100 g|||| |**Materials**|**Sensor Head**|Stainless steel|||| ||**Rubber sleeve**|Viton||None|| ||**Preamplifier**|Polycarbonate|||| ||**Mounting Brackets**|Stainless steel|||| |**Accessories**||Instruction manual, Preamplifier MountingBrackets (ZX-XBT1), Right-angle Adapter (See note 6.)|||| - **Note 1.** The resolution indicates the variation (±3 σ) in the linear output (voltage output) when a ZX-TDA@1 Amplifier Unit is connected. This value is taken 30 minutes after turning ON the power with the average number of operations set to 1,024. The minimum value that can be read is 1 μm. **2.** The linearity is given as the error in an ideal straight line displacement output. **3.** These figures are representative values that apply for the mid-point of the measurement range when the Actuator provided is secured facing downward. - ZX-TDS10T and ZX-TDS10T-V: The operating force will be reduced if the Actuator is secured facing horizontally or upward. - ZX-TDS10T-L and ZX-TDS10T-VL: The actuator can be installed only facing downward. **4.** These figures are representative values that apply for the mid-point of the measurement range. **5.** These values were measured at an ambient temperature of 23°C. **6.** The ZX-TDS10T comes with a Right-angle Adapter. **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 3 **Characteristic Data** ## **Output Characteristics Voltage/Current Output** **ZX-TDS01T/-TDS04T-@/-TDS10T-@@** **==> picture [270 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> Measurement distance (F.S)<br>4 V 20 mA<br>0 V 12 mA<br>Displacement direction<br>− +<br>−4 V (Released) (Pushed) 4 mA<br>Center<br>−0.5 mm 0 mm +0.5 mm Displacement<br>(−2 mm)*1 (+2 mm)*1<br>(−5 mm)*2 (+5 mm)*2<br>ON<br>High/Low output<br>OFF<br>Voltage output Analog output Voltage/current Current output<br>**----- End of picture text -----**<br> - *1: Values for the ZX-TDS04T/-TDS04T-@. - *2: Values for the ZX-TDS10T/-TDS10T-@@. ## **I/O Circuit Dia rams g** ## **NPN Amplifier Unit: ZX-TDA11** ## **PNP Amplifier Unit: ZX-TDA41** **==> picture [509 x 236] intentionally omitted <==** **----- Start of picture text -----**<br> Brown 12 to 24 V DC Brown 12 to 24 V DC<br>HIGH<br>HIGH Load judgement<br>WhiteGreen judgementoutputPASS judgement outputLOW judgement Load Load 12 to 24 V DC WhiteGreenGray outputoutputPASS judgement outputLOW judgement Load Load 12 to 24 V DC<br>Gray output<br>Load<br>Blue GND (0V)<br>Blue GND (0V)<br>Judgement output<br>Judgement output Pink hold input<br>Pink hold input<br>Purple Timing input<br>Purple Timing input<br>Orange Zero reset input<br>Orange Zero reset input<br>Red Reset input<br>Red Reset input<br>Current<br>output<br>Current (4 to 20mA)<br>Current/voltage output(4 to 20mA) Black Linear output Current/voltageoutput selector Black Linear output<br>output selector Voltage<br>Voltageoutput Load Current output: 100 Ω output±4V Load Current output: 300 Ω max.<br>100 Ω ±4V 300 Ω max. Shield Linear ground Voltage output:<br>Shield Linear ground Voltage output: 10 kΩ min.<br>10 kΩ min.<br>Internal circuit Internal circuit<br>**----- End of picture text -----**<br> **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 4 ## **Connectors** ## **Amplifier Unit** **==> picture [214 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> Brown<br>12 to 24 VDC<br>Blue<br>GND (0 V)<br>White<br>HIGH judgement output<br>Green<br>PASS judgement output<br>Gray<br>LOW judgement output<br>Black Linear output<br>Shield<br>Linear output GND<br>Pink<br>Judgement output hold input<br>Orange<br>Zero reset input<br>Purple<br>Timing input<br>Red<br>Reset input<br>**----- End of picture text -----**<br> - **Note 1.** Use a stabilized power supply separate from other devices and power systems for the Amplifier Unit, particularly when high resolution is required. **2.** Always wire correctly. Incorrect wiring may damage the Unit. Use a different ground for the linear output from the normal ground. **3.** The blue line (0 V) is the 0 V power supply line. The shield wire (linear output GND) is used together with the black line (linear output) to connect the linear output. Wire these lines correctly. Always ground the linear output terminal even when the linear output is not used. ## **Part Names** ## **Sensor Heads** **ZX-TDS01T ZX-TDS04T-@ ZX-TDS10T-@@** **==> picture [242 x 64] intentionally omitted <==** **----- Start of picture text -----**<br> Output cable<br>Sensor head Preamplifier (with connector)<br>**----- End of picture text -----**<br> ## **Amplifier Unit** **==> picture [39 x 14] intentionally omitted <==** **----- Start of picture text -----**<br> ZX-TDA11<br>ZX-TDA41<br>**----- End of picture text -----**<br> **==> picture [181 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> Controls<br>Display area<br>Input cable<br>(with connector)<br>Output cable<br>Connector<br>(Cover opens and closes)<br>**----- End of picture text -----**<br> ## **Calculating Unit** **==> picture [34 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> ZX-CAL2<br>**----- End of picture text -----**<br> **==> picture [143 x 108] intentionally omitted <==** **----- Start of picture text -----**<br> Display area<br>Connector<br>**----- End of picture text -----**<br> **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 5 ## **O tions Actuators p ( )** |**Model**|**Model**|**Type (material)**|**Screw section**|**Appearance**|**Application**|**Applicable**<br>**Sensor**<br>**(See note.)**| |---|---|---|---|---|---|---| |||||||**ZX-TDS@T**| |D5SN-|TB1<br>TB2<br>TB3<br>TN1<br>TF1<br>TA<br>~~A~~|Ball type (steel)|Female screw<br>M2.5 x 0.45||Measuring ordinary flat surfaces (stan-<br>dard actuator supplied with the ZX-TDS<br>Series)|| |||Ball type (carbide<br>steel)|Female screw<br>M2.5 x 0.45||Measurements where abrasion resistance<br>is critical<br>Measured objects: Carbide (HR90) or<br>lower.|| |||Ball type (ruby)|Female screw<br>M2.5 x 0.45||Measurements where abrasion resistance<br>is critical<br>Measured objects: Carbide (HR90) or<br>higher.|| |||Needle type (car-<br>bide steel)|Male screw<br>M2.5 x 0.45||Measuring the bottom of grooves and<br>holes|| |||Flat (carbide steel)|Male screw<br>M2.5 x 0.45||Measuring spherical objects|| |||Conversion Adapt-<br>er (stainless steel)<br>~~A~~|Through-hole fe-<br>male screw<br>M2.5 x 0.45<br>~~A~~|~~A~~<br>J|Mounting D5SN-TN1/-TF1 or commercial-<br>ly available actuators on ZX-TDS-series<br>Sensors<br> ~~fo~~|~~fo~~| **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 6 ## **Re lacin Actuators p g** Be careful not to damage the rubber boot with pliers or other tools when replacing the actuator. ## **1. Remove the standard actuator.** - Hold the plunger’s D-cut section with radio pliers or a similar tool while removing the actuator. - If the replacement must be performed by holding the Sensor Head itself, ensure that a torque exceeding 0.15 N·m is not applied. Applying excessive torque may have an adverse affect on plunger operation. **==> picture [218 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> Width: 1 mm<br>Rubber boot<br>D-cut section<br>Radio pliers or<br>a similar tool<br>**----- End of picture text -----**<br> ## **2. Mount the commercial actuator to the Conversion Adapter.** - Tighten the actuator securely, and ensure that there is no looseness. - If necessary, apply a screw-locking agent. (Recommended: Three-Bond 1401B) **==> picture [233 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> Conversion Adapter Commercially available<br>(D5SN-TA) actuator<br>(e.g., one with a flat end)<br>Screw-locking agent required<br>**----- End of picture text -----**<br> ## **3. Mount the Conversion Adapter to the plunger.** - Hold the plunger’s D-cut section with radio pliers or a similar tool while mounting and securing the Conversion Adapter. - If the replacement must be performed by holding the Sensor Head itself, ensure that a torque exceeding 0.15 N·m is not applied. Applying excessive torque may have an adverse affect on plunger operation. **==> picture [137 x 117] intentionally omitted <==** **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 7 **Precautions** ## **Design Precautions** - Conform to the specified ratings and performance. Refer to _Specifications_ on page 2 for details. - Measurements may not be possible or may not be accurate for some materials and shapes. - The Sensor will be destroyed if the Actuator is pressed too far. Do not use the Actuator past the point where a pressing force alarm (OVER) is displayed. - Do not remove the rubber boot. Without the rubber boot, foreign matter may enter the Sensor Head, possibly causing the Sensor Head to malfunction. - Use suitable torque and force when mounting the Sensor. - The Sensor may be destroyed if excessive force is applied. ## **Environment** - Do not operate the product in locations subject to flammable or explosive gases. - In order to ensure safe operation and maintenance, do not install the product in the vicinity of high-voltage devices or power equipment. ## **Wiring** - Do not use the product at voltages exceeding the rated values. Doing so may result in damage. - Do not connect the product to an AC power supply or connect the power supply in reverse. - Do not short-circuit the load for open-collector output. ## **Correct Use** ## ● **System Design** ## **Warming Up** After turning ON the power, allow the Smart Sensor to warm up for 15 minutes minimum prior to use. ## **Measurements** Do not expose the plunger to forces exceeding the limits in the following diagram. Doing so may damage the plunger. ## **ZX-TDS-Series Sensors** **==> picture [210 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> 30 N 30 N 1 N 0.15 N·m<br>**----- End of picture text -----**<br> ## ● **Adjustments** ## **Settings** When setting the threshold value with the Smart Sensor connected to an external device, turn ON the Amplifier Unit's judgement output hold input to prevent the judgement from being output to the external device. ## ● **Compatibility** Sensors and Amplifier Units are mutually compatible. Sensors can be added or replaced individually. ## ● **Influence of High-frequency Electromagnetic Fields** Using the product in the vicinity of devices that generate high-frequency electromagnetic fields, such as ultrasonic cleaning equipment, high-frequency generators, transceivers, mobile phones, and inverters, may result in malfunction. ## **Other Precautions** Do not attempt to disassemble, repair, or modify the product. Dispose of the product using standard procedures for industrial waste. These Sensors are not compatible with the ZX-L@@ Smart Sensors (laser type). Do not connect combinations of ZX-E@@ Smart Sensors and ZX-T@@ Smart Sensors. ## **Wiring** ## ● **Wiring Check** After wiring is completed, before turning ON the power, confirm that the power supply is connected correctly, that there are no faulty connections, such as load short-circuits, and that the load current is correct. Incorrect wiring may result in failure. ## ● **Cable Extension** Do not extend the cable for the Sensor and the Amplifier Unit to a length exceeding 10 m. Use a ZX-XC@A Extension Cable (sold separately) to extend the Sensor’s cable. Extend the Amplifier Unit’s cable using a shielded cable of the same type. ## ● **Power Supply** When using a commercially available switching regulator, ground the FG (frame ground) terminal. If the power supply line is subject to surges, connect a surge absorber that meets the conditions of the operating environment. ## **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 8 ## **Dimensions** ## **Sensors** **ZX-TDS01T** Vinyl-insulated round cable 4.5 dia. 6[0] −0.1 dia. 3.7 dia., standard length: 2 m Vinyl-insulated round cable5.2 dia., standard length: 200 mm 15 dia. Measurement SR1.5 range* 16 Connector 41.6 ±0.4 46 5.95 44.6 ±0.8 * Measurement range: 11.2 to 12.2 (TYP) N. ~~a~~ 57.1 ±1 **ZX-TDS04T ZX-TDS04T-L** Vinyl-insulated round cable 3.7 dia., standard length: 2 m Vinyl-insulated round cable 4.5 dia. 6[0] −0.1[ dia.] 5.2 dia., standard length: 200 mm 15 dia. Measurement SR1.5 ~~SS~~ range* ~~eS Sp~~ 16 Connector 63.4 ±0.4 46 13.1 66.4 ±0.8 * Measurement range: 14.9 to 18.9 (TYP) N. ~~LE~~ 86 ±1.5 **ZX-TDS10@** 123 Vinyl-insulated round cable Vinyl-insulated round cable 22 84.5 12.5 3.7 dia., standard length: 2 m 16 5.2 dia., standard length: 200 mm 5 dia. 15 dia. SR1.5 8dia., H6 ~~|~~ 88 Connector 97 ± 1 46 ~~97 ± 1 ——~~ a ~~———— I)~~ 20 ~~i ——— 27 84.8~~ **ZX-TDS10@-L** 132.15 28.5 84.5 24.2 9.5 1.2 7.5 dia. ~~2~~ a ~~2~~ 10 8 dia., H6 SR1.5 Vinyl-insulated round cable Vinyl-insulated round cable 3.7 dia., standard length: 2 m 16 5.2 dia., standard length: 200 mm 15 dia. 88 Connector ~~i~~ 97 ± 1 ~~—l |~~ 46 ~~97 ± 1 SSS~~ 20 ~~Seee oy 27 84.8~~ **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 9 **ZX-TDS10@-V** **==> picture [475 x 223] intentionally omitted <==** **----- Start of picture text -----**<br> 129.5<br>26 84.5<br>22.17 9.5 7.3<br>5 dia. 10<br>3.4<br>SR1.5 8 dia., H6<br>2.4 Vinyl-insulated round cable Vinyl-insulated round cable<br>3.7 dia., standard length: 2 m 16 5.2 dia., standard length: 200 mm<br>15 dia.<br>88 Connector<br>97 ± 1 46<br>97 ± 1<br>20<br>27<br>84.8<br>**----- End of picture text -----**<br> ## **ZX-TDS10@-VL** **==> picture [485 x 229] intentionally omitted <==** **----- Start of picture text -----**<br> 124.5<br>21 84.5<br>15 9.5 7.3<br>5 dia.<br>7 dia. 10<br>SR1.5 1.8 8 dia., H6 3.4<br>2.4<br>Vinyl-insulated round cable Vinyl-insulated round cable<br>3.7 dia., standard length: 2 m 16 5.2 dia., standard length: 200 mm<br>15 dia.<br>88 Connector<br>97 ± 1 46<br>97 ± 1<br>20<br>27<br>84.8<br>**----- End of picture text -----**<br> **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 10 **Amplifier Unit** **ZX-TDA11 ZX-TDA41** **==> picture [481 x 248] intentionally omitted <==** **----- Start of picture text -----**<br> Mm 133<br>44 4.2 64.3 4.2<br>3 0 3<br>31.5<br>15.5 dia.<br>ee 13.2 || | l ege? 15.8<br>N e ) — t " Z _ 13 L 36.8 Ss Vinyl-insulated round cable = t |<br>Vinyl-insulated round cable 5.2 dia., 10 conductors,<br>5.1 dia., standard length: 100 mm (conductor cross-section:<br>0.09 mm [2] , insulator diameter: 0.7-mm dia.),<br>11.7 standard length: 2 m<br>11.7<br>a= a i at a —<br>i] = | Wy.Gh aea—<br>2.2 Current/voltage switch<br>29 (Factory-set to voltage output)<br>al Voltage output<br>**----- End of picture text -----**<br> ## ■ **Accessories (Order Separately)** ## **Preamplifier Mounting Bracket (Supplied with Each Sensor)** ## **ZX-XBT1** ## **ZX-XBT2 (For DIN Track Mounting)** **==> picture [489 x 209] intentionally omitted <==** **----- Start of picture text -----**<br> Four, 1.6R<br>4.8<br>3.2<br>== 27 == M3 x 8 pan-head screw (with M3 spring washer)<br>(91.1)<br>(16.4) 75<br>29 (16.4)<br>(28.1)<br>11.8<br>(28.1)<br>(38) 10 6.2<br>(91.1)<br>Material: Stainless steel<br>1 1.8 1.8 ! 10 g<br>Mounting Hole Cutout Dimensions 9.4<br>35.3 11.4<br>Two, M3 58<br>84.8<br>27± [0.1]<br>Material: Stainless steel<br>tt ES<br>**----- End of picture text -----**<br> **ZX Series (ZX-T)** Smart Sensors (High-precision Contact Type) 11 This document provides information mainly for selecting suitable models. Please read the document E346 carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. ## **ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.** To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. CSM_2_1_0215 Cat. No. E345-E1-04 **In the interest of product improvement, specifications are subject to change without notice.** **OMRON Corporation Industrial Automation Company** **Sensing Devices Division H.Q. Application Sensors Division** Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7068/Fax: (81)75-344-7107 0407(1203)
Updated at June 9, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →