XW5Z-EP6
Accessory, Omron Feed Through and Grounding Terminal Blocks, End Bracket
- Manufacturer: OMRON INDUSTRIAL AUTOMATION
- Product type: Terminal Block Accessories
- SVHC: To Be Advised
- For Use With: Omron Feed Through and Grounding Terminal Blocks
- Product Range: -
- Accessory Type: End Bracket
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 0.651 € |
| Current stock | 10+ |
| Lead time | 30 days |
**New Product** ## **DIN Track Push-in Terminal Blocks XW5T** ## **Push-in Plus Terminal Blocks to Downsize Control Panels and Save** ## **Work** - Push-in Plus terminal blocks are more compact than traditional screw terminal blocks. No loosening means maintenance-free application. - Slim models available down to a width of 3.5 mm to help downsize control panels. - Light insertion force and strong holding strength to achieve both less wiring work and high reliability. - 'Hands-free' structure that holds an inserted screwdriver to achieve better workability when wiring stranded wires without crimp terminals. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to _Safety Precautions_ on page 17. ## **Model Number Legend** **Feed Through Terminal Blocks** ## **XW5T - P** @ **-** @ **-** @@ - (1) (2) (3)(4) **(2) Wiring** **(1) Maximum Applicable Stranded Wire** 1.1: 1:1 1.5: 1.5mm[2] 1.2: 1:2 ## **Grounding Terminal Blocks** ## **XW5G - P** @ **-** @ **-** @ (1) (2) (3) **(3) Number of Tiers** **(4) Color** Blank: Dark gray BL: Blue 1: 1 tier 2: 2 tiers 2.5: 2.5mm[2] 4.0: 4.0mm[2] 2.2: 2:2 **1** **XW5T Part Names and Configuration** ## **DIN Track Terminal Block (Top Surface)** Terminal (insertion) hole Release hole (to release wire) Short Bar insertion holes - You can attach a Short Bar to either of the two holes. - Insert the tester pins here to perform a continuity check. Label attachment section - **Note: 1.** Do not insert more than one wire into one terminal (insertion) hole. **2.** Do not insert more than one Short Bar into one Short Bar insertion hole. ## **Basic Configuration** Short Bar Nameplate or Labels End Cover End Brackets DIN Track End Brackets Terminal Block |**Name**|**Description**| |---|---| |DIN Track|Both Feed Through and Grounding Terminal Blocks are| |Terminal Blocks|available.| ||This part is required to prevent electric shock.| |End Cover|Attach one End Cover to the exposed metal surface of the<br>last Terminal Block or to any Terminal Block that is next to| ||a different shape of Terminal Block.| |End Brackets|End Brackets must be attached to both ends to hold the<br>Terminal Block in place.| ||This part is available as an accessory.| |Nameplate or|Select the most suitable one for your needs.| |Labels|You can also use commercially available nameplates that| ||are 9.5 mm wide and 0.5 mm thick.*| |Short Bar|This part is available as an accessory.<br>Select one as required.| * Two-tier Terminal Blocks with a width of 3.5 mm are excluded. **2** **XW5T** ## **Ordering Information** |**Classification**|**Product Type**<br>~~re~~|**Nominal Cross**<br>**Section**<br>**(mm2)**<br>~~re~~<br>~~ee~~|**Number of**<br>**levels**<br>~~eee~~<br>~~ee~~|**Number of cramp**<br>**position per level**<br>~~eee~~|**Color**<br>~~eee~~<br>~~||~~|**Weight**<br>**(gram)**<br>~~eee~~<br>~~||~~|**Model**| |---|---|---|---|---|---|---|---| |Feed Through<br>Terminal blocks|Standard terminals|1.0<br>~~ee~~<br>~~ee~~|1<br>~~ee~~<br>~~ee~~|2|Dark grey<br>~~||~~<br>~~||~~<br>~~ee~~<br>~~||~~<br>~~||~~|3.3<br>~~||~~<br>~~||~~|**XW5T-P1.5-1.1-1**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~||6.3<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P2.5-1.1-1**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~||8.4<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P4.0-1.1-1**| |||1.0<br>~~ee~~<br>~~ee~~<br>~~ee~~|1<br>~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~|Blue<br>~~ee~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~|3.3<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P1.5-1.1-1BL**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2||6.3<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P2.5-1.1-1BL**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2||8.4<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P4.0-1.1-1BL**| ||Multi tiers terminal|1.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|2<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2|Dark grey<br>~~||~~<br>~~||~~<br>~~||~~<br>~~ee~~<br>~~||~~<br>~~||~~|6.5<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P1.5-1.1-2**| |||2.5<br>~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~||12.5<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P2.5-1.1-2**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|2<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~||16.5<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P4.0-1.1-2**| |||1.0<br>~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~|Blue<br>~~ee~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~|6.5<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P1.5-1.1-2BL**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|2<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2||12.5<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P2.5-1.1-2BL**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|2<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2||16.5<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P4.0-1.1-2BL**| ||Multi conductor<br>terminals|1.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|3|Dark grey<br>~~||~~<br>~~||~~<br>~~||~~<br>~~ee~~<br>~~||~~<br>~~||~~|4.1<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P1.5-1.2-1**| |||2.5<br>~~ee~~<br>~~ee~~<br>~~ee~~|1<br>~~ee~~<br>~~ee~~<br>~~ee~~|3<br>~~ee~~||8.2<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P2.5-1.2-1**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|3<br>~~ee~~||10.8<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P4.0-1.2-1**| |||1.0<br>~~ee~~<br>~~ee~~<br>~~ee~~|1<br>~~ee~~<br>~~ee~~<br>~~ee~~|3<br>~~ee~~<br>~~ee~~|Blue<br>~~ee~~<br>~~||~~<br>~~||~~<br>~~ee~~<br>~~||~~<br>~~||~~<br>~~||~~|4.1<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P1.5-1.2-1BL**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|3<br>~~ee~~||8.2<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P2.5-1.2-1BL**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|3<br>~~ee~~||10.8<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P4.0-1.2-1BL**| |||1.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|4|Dark grey<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~|4.9<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P1.5-2.2-1**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|4||10.4<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P2.5-2.2-1**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|4||13.4<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P4.0-2.2-1**| |||1.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|4|Blue<br>~~||~~<br>~~||~~<br>~~||~~<br>~~ee~~<br>~~||~~<br>~~||~~|4.9<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P1.5-2.2-1BL**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|4<br>~~ee~~||10.4<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P2.5-2.2-1BL**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|4<br>~~ee~~||13.4<br>~~||~~<br>~~||~~<br>~~||~~|**XW5T-P4.0-2.2-1BL**| |Grounding<br>Terminal blocks|Standard terminals|1.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2<br>~~ee~~|Green/yellow<br>~~ee~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~<br>~~||~~|4.7<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P1.5-1.1-1**| |||2.5<br>~~ee~~<br>~~ee~~<br>~~ee~~|1<br>~~ee~~<br>~~ee~~<br>~~ee~~|2||9.9<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P2.5-1.1-1**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2||11.8<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P4.0-1.1-1**| ||Multi tiers terminal|1.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|2<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2||8.1<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P1.5-1.1-2**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|2<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2||16.6<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P2.5-1.1-2**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|2<br> ~~ee~~<br>~~ee~~<br>~~ee~~|2||20.8<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P4.0-1.1-2**| ||Multi conductor<br>terminals|1.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|3||5.5<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P1.5-1.2-1**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|3||11.6<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P2.5-1.2-1**| |||4.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|3||14.1<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P4.0-1.2-1**| |||1.0<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|4||6.3<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P1.5-2.2-1**| |||2.5<br>~~ee ~~<br>~~ee~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~<br>~~ee~~|4||13.8<br>~~||~~<br>~~||~~<br>~~||~~|**XW5G-P2.5-2.2-1**| |||4.0<br>~~ee ~~<br>~~ee~~|1<br> ~~ee~~<br>~~ee~~|4||16.7<br>~~||~~<br>~~||~~|**XW5G-P4.0-2.2-1**| ## **Accessories** ## **Short Bars** **For XW5T-P1.5- @** |**Appearance**|**No. of poles**|**Colors**|**Model***|**Application**| |---|---|---|---|---| |Fm AA A<br>AA | mm|2|Red (RD)<br>Blue (BL)<br>Yellow (YL)|**XW5S-P1.5-2@**|Used for cross-over wiring between Terminal Blocks.| ||3||**XW5S-P1.5-3@**|| ||4||**XW5S-P1.5-4@**|| ||5||**XW5S-P1.5-5@**|| ||10||**XW5S-P1.5-10@**|| * Replace the box ( @ ) in the model number with the code for the covering color. Specify the color: RD = red, BL = blue, YL = yellow ## **For XW5T-P2.5- @** |**Appearance**|**No. of poles**|**Colors**|**Model***|**Application**| |---|---|---|---|---| |mmf<br>FTTTTTT FATT|2|Red (RD)<br>Blue (BL)<br>Yellow (YL)|**XW5S-P2.5-2@**|Used for cross-over wiring between Terminal Blocks.| ||3||**XW5S-P2.5-3@**|| ||4||**XW5S-P2.5-4@**|| ||5||**XW5S-P2.5-5@**|| ||10||**XW5S-P2.5-10@**|| * Replace the box ( @ ) in the model number with the code for the covering color. Specify the color: RD = red, BL = blue, YL = yellow **3** omron ~~a~~ **XW5T** ## **For XW5T-P4.0- @** |**Appearance**|**No. of poles**|**Colors**|**Model***|**Application**| |---|---|---|---|---| ||2|Red (RD)<br>Blue (BL)<br>Yellow (YL)|**XW5S-P4.0-2@**|Used for cross-over wiring between Terminal Blocks.| ||3||**XW5S-P4.0-3@**|| ||4||**XW5S-P4.0-4@**|| ||5||**XW5S-P4.0-5@**|| ||10||**XW5S-P4.0-10@**|| * Replace the box ( @ ) in the model number with the code for the covering color. Specify the color: RD = red, BL = blue, YL = yellow **Labels Appearance Terminal BlocksApplicable Model Minimum order in sheets (quantity per sheet) Application XW5Z-P1.5LB1** 5 sheets with 102 top labels per sheet XW5 **@** -P1.5- **@ XW5Z-P1.5LB2** 5 sheets with 108 side labels per sheet XW5 **@** -P2.5- **@ XW5Z-P2.5LB1** 5 sheets with 72 top labels per sheet Used to identify wiring. (Material: PA **XW5Z-P2.5LB2** 5 sheets with 72 side labels per sheet resin, blank) **XW5Z-P4.0LB1** 5 sheets with 60 top labels per sheet XW5 **@** -P4.0- **@ XW5Z-P4.0LB2** 5 sheets with 60 side labels per sheet ~~=~~ **Note: 1.** Different models are used for the top and side surfaces. **2.** There is no place to mount the Top-surface Labels on Two-tier Terminal Blocks with a width of 3.5 mm, so they cannot be used. **3.** If you use commercially available nameplates (9.5 mm width and 0.5 mm thickness), you can use a commercially available printer. Check with the manufacturer of the nameplates for information on applicable printers. **4.** Refer to page 20 for details on printing labels. ## **End Cover** |**Appearance**|**Applicable Terminal Blocks**|**Model**|**Application**| |---|---|---|---| ||XW5@-P1.5-1.1-1|**XW5E-P1.5-1.1-1**|This part is required to prevent electric shock.<br>Always mount End Covers to the following locations when you<br>use Terminal Blocks. (For details, refer to page 21.)<br>• Exposed metal surface of the last Terminal Block<br>• Any Terminal Block that is next to a different shape of<br>Terminal Block| ||XW5@-P1.5-1.1-2|**XW5E-P1.5-1.1-2**|| ||XW5@-P1.5-1.2-1|**XW5E-P1.5-1.2-1**|| ||XW5@-P1.5-2.2-1|**XW5E-P1.5-2.2-1**|| ||XW5@-P2.5-1.1-1|**XW5E-P2.5-1.1-1**|| ||XW5@-P2.5-1.1-2|**XW5E-P2.5-1.1-2**|| ||XW5@-P2.5-1.2-1|**XW5E-P2.5-1.2-1**|| ||XW5@-P2.5-2.2-1|**XW5E-P2.5-2.2-1**|| ||XW5@-P4.0-1.1-1|**XW5E-P4.0-1.1-1**|| ||XW5@-P4.0-1.1-2|**XW5E-P4.0-1.1-2**|| ||XW5@-P4.0-1.2-1|**XW5E-P4.0-1.2-1**|| ||XW5@-P4.0-2.2-1|**XW5E-P4.0-2.2-1**|| XW5 @ -P4.0-2.2-1 **XW5E-P4.0-2.2-1** **End Brackets Appearance Width (mm) Model Application** End Brackets are installed on the ends of the Terminal Blocks 6 **XW5Z-EP6** to prevent them from moving on the DIN Track. ~~ee~~ **Separator Plates Appearance Width (mm) Model Application** This part is used to create insulation distance. 12 **XW5Z-EP12** Use Separator Plates according to the clearance and creeping distances required by the operating conditions of your equipment. ~~a~~ **Note:** Refer to _6. Using the Accessories_ on page 20 for information on using the accessories. **4** **XW5T** ## **Ratings and Performance** ## **Ratings** ## **Feed Through Terminal blocks Standard terminals** |**Model**|**Model**|**XW5T-P1.5-1.1-1 (BL)**|**XW5T-P1.5-1.1-1 (BL)**|**XW5T-P1.5-1.1-1 (BL)**|**XW5T-P1.5-1.1-1 (BL)**|**XW5T-P2.5-1.1-1 (BL)**|**XW5T-P4.0-1.1-1 (BL)**| |---|---|---|---|---|---|---|---| |**Appearance and internal**<br>**wiring**||1 tier, 1:1||||1 tier, 1:1|1 tier, 1:1<br>~~ou~~| |**Applicable wire sizes*1**|**NOMINAL CROSS**<br>**SECTION**|0.75 mm2(1.5 mm2)*2||||2.5 mm2|4 mm2| ||**Minimum conductor**<br>**cross section solid**<br>~~———~~|0.14 mm2<br>~~———~~||||0.14 mm2<br>~~———~~|0.2 mm2| ||**Maximum conductor**<br>**cross section solid**<br>~~———~~|1.5 mm2<br>~~———~~||||4.0 mm2<br>~~———~~|6.0 mm2| ||**Minimum conductor**<br>**cross section fine**<br>**stranded**<br>~~———~~|0.08 mm2<br>~~———~~||||0.14 mm2<br>~~———~~|0.2 mm2| ||**Maximum conductor**<br>**cross section fine**<br>**stranded**<br>~~———~~<br>~~Wi~~|1.5 mm2<br>~~———~~<br>~~Wi~~||||2.5 mm2<br>~~———~~<br>~~i~~|4.0 mm2| ||**Minimum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**<br>~~Wi~~<br>~~Wi~~|0.14 mm2<br>~~Wi~~<br>~~hhi~~||||0.14 mm2<br>~~i~~<br>~~i~~|0.25 mm2| ||**Maximum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**<br>~~Wi~~<br>~~Wi~~|0.75 mm2(1.5 mm2)*2<br>~~Wi~~<br>~~hhi~~||||2.5 mm2<br>~~i~~<br>~~i~~|4.0 mm2| |**Dimensions**<br>~~Wi ~~||3.5 × 45 × 30.5<br> ~~hh i~~||||5.2 × 48.8 × 35.3<br>~~i~~|6.2 × 56.1 × 35.3| |**IEC rated voltage**||500 V||||800 V|800 V| |**IEC rated current**||17.5 A/1.5 mm2<br>~~———~~||||24 A/2.5 mm2<br>~~———~~|32 A/4.0 mm2| |**Usage Group (UG)**||B, C<br>~~———~~|D<br>~~———~~|||B, C<br>~~———~~|| |**UL rated voltage**||300 V<br>~~———~~|51-150 V<br>~~———~~|151-300 V<br>~~———~~|301-600 V<br>~~———~~|600 V<br>~~———~~|| |**UL rated current**||15 A/AWG14<br>(SOL)<br>10 A/AWG16<br>~~———~~|15 A/AWG14<br>(SOL)<br>10 A/AWG16<br>~~———~~|10 A/<br>AWG16<br>~~———~~|5 A/<br>AWG16-20<br>~~———~~|20 A/AWG12 (SOL), 15 A/AWG14<br>~~———~~|30 A/AWG10 (SOL), 20 A/AWG12| |**Dielectric strength**||1,890 VAC for 1 min<br>(leakage current: 1 mA max.)||||2,000 VAC for 1 min<br>(leakage current: 1 mA max.)|2,000 VAC for 1 min<br>(leakage current: 1 mA max.)| |**End Cover**||XW5E-P1.5-1.1-1||||XW5E-P2.5-1.1-1|XW5E-P4.0-1.1-1| |**Special tool**<br>~~|p|~~||XW4Z-00B<br>~~|p|~~||||XW4Z-00B<br>~~|p|__~~|XW4Z-00B| |**Applicable nameplates**<br>~~|p|~~||XW5Z-P1.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness<br>~~|p|~~||||XW5Z-P2.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness<br>~~|p|__~~|XW5Z-P4.0LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness| |**Applicable Short Bars**<br>~~|p|~~||XW5S-P1.5-@<br>(@: Poles = 2, 3, 4, 5 or 10)<br>~~|p|~~||||XW5S-P2.5-@<br>(@: Poles = 2, 3, 4, 5 or 10)<br>~~|p|__~~|XW5S-P4.0-@<br>(@: Poles = 2, 3, 4, 5 or 10)| *1. For the applicable wire ranges, refer to page 17 for solid and stranded wires and to page 19 for ferrules. *2. You can also use ferrules for 1.0 to 1.5 mm[2] wires if you use ferrules without insulation sleeve. **5** omron ~~a~~ **XW5T** ## **Feed Through Terminal blocks Multi tiers terminal** |**Model**|**Model**|**XW5T-P1.5-1.1-2 (BL)**<br>~~a~~|**XW5T-P1.5-1.1-2 (BL)**<br>~~a~~|**XW5T-P1.5-1.1-2 (BL)**<br>~~a~~|**XW5T-P1.5-1.1-2 (BL)**<br>~~a~~|**XW5T-P2.5-1.1-2 (BL)**<br>~~a~~|**XW5T-P4.0-1.1-2 (BL)**| |---|---|---|---|---|---|---|---| |**Appearance and internal**<br>**wiring**||2 tiers, 1:1<br>o——~~o~~||||2 tiers, 1:1<br>o——~~o~~|2 tiers, 1:1<br>o~~o~~<br>—_——o| |**Applicable wire sizes*1**|**NOMINAL CROSS**<br>**SECTION**|0.75 mm2(1.5 mm2)*2||||2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section solid**|0.14 mm2||||0.14 mm2|0.2 mm2| ||**Maximum conductor**<br>**cross section solid**|1.5 mm2||||4.0 mm2|6.0 mm2| ||**Minimum conductor**<br>**cross section fine**<br>**stranded**|0.08 mm2||||0.14 mm2|0.2 mm2| ||**Maximum conductor**<br>**cross section fine**<br>**stranded**|1.5 mm2||||2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.14 mm2||||0.14 mm2|0.25 mm2| ||**Maximum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.75 mm2(1.5 mm2)*2||||2.5 mm2|4.0 mm2| |**Dimensions**||3.5 × 65.7 × 41.1<br>~~ee~~||||5.2 × 78.8 × 45.9<br>~~ee~~|6.2 × 85 × 45.9| |**IEC rated voltage**||500 V|||||| |**IEC rated current**||17.5 A/1.5 mm2<br>~~ee~~||||22 A/2.5 mm2<br>~~ee~~|28 A/4.0 mm2| |**Usage Group (UG)**||B, C<br>~~PoP~~|D<br>~~PoP~~|||B, C|| |**UL rated voltage**||300 V<br>~~et;~~|51-150 V<br>~~et;~~<br>~~|~~|151-300 V<br>~~pp~~|301-600 V<br>~~pp~~|600 V<br>~~pp~~|| |**UL rated current**||15 A/AWG14<br>(SOL)<br>10 A/AWG16<br>~~et;~~|15 A/AWG14<br>(SOL)<br>10 A/AWG16<br>~~et;~~<br>~~|~~|10 A/<br>AWG16<br>~~pp~~|5 A/<br>AWG16-20<br>~~pp~~|20 A/AWG12 (SOL),<br>15 A/AWG14<br>~~pp~~|30 A/AWG10 (SOL),<br>20 A/AWG12| |**Dielectric strength**||1,890 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~et;~~<br>~~|pp~~||||2,000 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~pp~~|| |**End Cover**||XW5E-P1.5-1.1-2<br>~~es~~||||XW5E-P2.5-1.1-2<br>~~es~~|XW5E-P4.0-1.1-2| |**Special tool**||XW4Z-00B<br>~~es~~|||||| |**Applicable nameplates**||XW5Z-P1.5LB2||||XW5Z-P2.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness|XW5Z-P4.0LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness| |**Applicable Short Bars**||XW5S-P1.5-@<br>(@: Poles = 2, 3, 4, 5 or 10)||||XW5S-P2.5-@<br>(@: Poles = 2, 3, 4, 5 or 10)|XW5S-P4.0-@<br>(@: Poles = 2, 3, 4, 5 or 10)| *1. For the applicable wire ranges, refer to page 17 for solid and stranded wires and to page 19 for ferrules. *2. You can also use ferrules for 1.0 to 1.5 mm[2] wires if you use ferrules without insulation sleeve. **6** **XW5T** ## **Feed Through Terminal blocks Multi conductor terminals** |**Model**|**Model**|**XW5T-P1.5-1.2-1 (BL)**<br>~~ee~~|**XW5T-P1.5-1.2-1 (BL)**<br>~~ee~~|**XW5T-P1.5-1.2-1 (BL)**<br>~~ee~~|**XW5T-P1.5-1.2-1 (BL)**<br>~~ee~~|**XW5T-P2.5-1.2-1 (BL)**<br>~~ee~~|**XW5T-P4.0-1.2-1 (BL)**| |---|---|---|---|---|---|---|---| |**Appearance and internal**<br>**wiring**||1 tier, 1:2<br>se<br>O~~=——0-~~O||||1 tier, 1:2<br>O~~=—=O0-~~O|1 tier, 1:2<br>fal aie<br>O~~=——0-~~O| |**Applicable wire sizes*1**|**NOMINAL CROSS**<br>**SECTION**|0.75 mm2(1.5 mm2)*2||||2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section solid**|0.14 mm2||||0.14 mm2|0.2 mm2| ||**Maximum conductor**<br>**cross section solid**|1.5 mm2||||4.0 mm2|6.0 mm2| ||**Minimum conductor**<br>**cross section fine**<br>**stranded**|0.08 mm2||||0.14 mm2|0.2 mm2| ||**Maximum conductor**<br>**cross section fine**<br>**stranded**|1.5 mm2||||2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.14 mm2||||0.14 mm2|0.25 mm2| ||**Maximum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.75 mm2(1.5 mm2)*2||||2.5 mm2|4.0 mm2| |**Dimensions**||3.5 × 54.1 × 30.5<br>~~es~~||||5.2 × 60.5 × 35.3<br>~~es~~|6.2 × 66.5 × 35.3| |**IEC rated voltage**||500 V<br>~~ee~~||||800 V|| |**IEC rated current**||17.5 A/1.5 mm2<br>~~es~~<br>~~eeee~~||||24 A/2.5 mm2<br>~~es~~|32 A/4.0 mm2| |**Usage Group (UG)**||B, C<br>~~ee~~|D<br>~~ee~~|||B, C|| |**UL rated voltage**||300 V<br>~~ee~~<br>~~Pt~~|51-150 V<br>~~ee~~<br>~~Ptpf~~|151-300 V<br>~~ee~~<br>~~pf~~|301-600 V<br>~~ee~~<br>|600 V<br>|| |**UL rated current**||15 A/AWG14<br>(SOL)<br>10 A/AWG16<br>~~Pt~~|15 A/AWG14<br>(SOL)<br>10 A/AWG16<br>~~Ptpf~~|10 A/<br>AWG16<br>~~pfEp~~|5 A/<br>AWG16-20<br>~~Ep~~|20 A/AWG12 (SOL),<br>15 A/AWG14<br>~~Ep~~|30 A/AWG10 (SOL),<br>20 A/AWG12| |**Dielectric strength**||1,890 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~Pt pf~~||||2,000 VAC for 1 min<br>(leakage current: 1 mA max.)<br>|| |**End Cover**||XW5E-P1.5-1.2-1<br>~~es~~||||XW5E-P2.5-1.2-1<br>~~es~~|XW5E-P4.0-1.2-1| |**Special tool**||XW4Z-00B<br>~~es~~|||||| |**Applicable nameplates**||XW5Z-P1.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness||||XW5Z-P2.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness|XW5Z-P4.0LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness| |**Applicable Short Bars**||XW5S-P1.5-@<br>(@: Poles = 2, 3, 4, 5 or 10)||||XW5S-P2.5-@<br>(@: Poles = 2, 3, 4, 5 or 10)|XW5S-P4.0-@<br>(@: Poles = 2, 3, 4, 5 or 10)| *1. For the applicable wire ranges, refer to page 17 for solid and stranded wires and to page 19 for ferrules. *2. You can also use ferrules for 1.0 to 1.5 mm[2] wires if you use ferrules without insulation sleeve. **7** **XW5T** |**Model**|**Model**|**XW5T-P1.5-2.2-1 (BL)**<br>~~es~~|**XW5T-P1.5-2.2-1 (BL)**<br>~~es~~|**XW5T-P1.5-2.2-1 (BL)**<br>~~es~~|**XW5T-P1.5-2.2-1 (BL)**<br>~~es~~|**XW5T-P2.5-2.2-1 (BL)**<br>~~es~~|**XW5T-P4.0-2.2-1 (BL)**| |---|---|---|---|---|---|---|---| |**Appearance and internal**<br>**wiring**||1 tier, 2:2<br>~~se~~<br>O~~-O=0-~~0||||1 tier, 2:2<br>~~se~~<br>O~~-O=0-~~0|1 tier, 2:2<br>O~~-O=0-0~~| |**Applicable wire sizes*1**|**NOMINAL CROSS**<br>**SECTION**|0.75 mm2(1.5 mm2)*2||||2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section solid**|0.14 mm2||||0.14 mm2|0.2 mm2| ||**Maximum conductor**<br>**cross section solid**|1.5 mm2||||4.0 mm2|6.0 mm2| ||**Minimum conductor**<br>**cross section fine**<br>**stranded**|0.08 mm2||||0.14 mm2|0.2 mm2| ||**Maximum conductor**<br>**cross section fine**<br>**stranded**|1.5 mm2||||2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.14 mm2||||0.14 mm2|0.25 mm2| ||**Maximum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.75 mm2(1.5 mm2)*2||||2.5 mm2|4.0 mm2| |**Dimensions**||3.5 × 63.2 × 30.5<br>~~ee~~||||5.2 × 72.2 × 35.3<br>~~ee~~|6.2 × 76.9 × 35.3| |**IEC rated voltage**||500 V<br>~~PO~~||||800 V|| |**IEC rated current**||17.5 A/1.5 mm2<br>~~ee~~||||24 A/2.5 mm2<br>~~ee~~|32 A/4.0 mm2| |**Usage Group (UG)**||B, C<br>~~a ee~~|D<br>~~ee~~|||B, C|| |**UL rated voltage**||300 V<br>~~a ee~~<br>~~Pt;~~|51-150 V<br>~~ee~~<br>~~Pt;pp~~|151-300 V<br>~~ee~~<br>~~pp~~|301-600 V<br>~~ee~~<br>~~pp~~|600 V|| |**UL rated current**||15 A/AWG14<br>(SOL)<br>10 A/AWG16<br>~~Pt;~~|15 A/AWG14<br>(SOL)<br>10 A/AWG16<br>~~Pt;pp~~|10 A/<br>AWG16<br>~~pp~~|5 A/<br>AWG16-20<br>~~pp~~|20 A/AWG12 (SOL),<br>15 A/AWG14|30 A/AWG10 (SOL),<br>20 A/AWG12| |**Dielectric strength**||1,890 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~Pt; pp~~||||2,000 VAC for 1 min<br>(leakage current: 1 mA max.)|| |**End Cover**||XW5E-P1.5-2.2-1<br>~~ee~~||||XW5E-P2.5-2.2-1<br>~~ee~~|XW5E-P4.0-2.2-1| |**Special tool**||XW4Z-00B|||||| |**Applicable nameplates**||XW5Z-P1.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness||||XW5Z-P2.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness|XW5Z-P4.0LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness| |**Applicable Short Bars**||XW5S-P1.5-@<br>(@: Poles = 2, 3, 4, 5 or 10)||||XW5S-P2.5-@<br>(@: Poles = 2, 3, 4, 5 or 10)|XW5S-P4.0-@<br>(@: Poles = 2, 3, 4, 5 or 10)| *1. For the applicable wire ranges, refer to page 17 for solid and stranded wires and to page 19 for ferrules. *2. You can also use ferrules for 1.0 to 1.5 mm[2] wires if you use ferrules without insulation sleeve. **8** **XW5T** ## **Grounding Terminal blocks Standard terminals** |**Model**|**Model**|**XW5G-P1.5-1.1-1**<br>~~a~~|**XW5G-P2.5-1.1-1**<br>~~a~~|**XW5G-P4.0-1.1-1**| |---|---|---|---|---| |**Appearance and internal**<br>**wiring**<br>~~es~~||1 tier, 1:1<br>~~a~~<br>a|1 tier, 1:1<br>~~a~~<br>a<br>~~ee~~|1 tier, 1:1<br>~~a~~| |**Applicable wire sizes*1**|**NOMINAL CROSS**<br>**SECTION**<br>~~ee~~<br>~~es~~<br>~~es~~|0.75 mm2(1.5 mm2)*2<br>~~ee~~<br>~~**ee**~~|2.5 mm2<br>~~ee~~<br>~~ee~~<br>~~**ee**~~|4 mm2| ||**Minimum conductor**<br>**cross section solid**<br>~~ee~~<br>~~es~~<br>~~es~~|0.14 mm2<br>~~ee~~<br>~~**ee**~~|0.14 mm2<br>~~ee~~<br>~~ee~~<br>~~**ee**~~|0.2 mm2| ||**Maximum conductor**<br>**cross section solid**<br>~~es~~<br>~~es~~|1.5 mm2<br>~~**ee**~~|4.0 mm2<br>~~ee~~<br>~~**ee**~~|6.0 mm2| ||**Minimum conductor**<br>**cross section fine**<br>**stranded**<br>~~es~~<br>~~ee~~|0.08 mm2<br>~~**ee**~~<br>~~ee~~|0.14 mm2<br>~~**ee**~~<br>~~ee~~|0.2 mm2| ||**Maximum conductor**<br>**cross section fine**<br>**stranded**|1.5 mm2|2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**<br>~~a~~|0.14 mm2<br>~~eee~~|0.14 mm2<br>~~eee~~|0.25 mm2| ||**Maximum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**<br>~~a ~~|0.75 mm2(1.5 mm2)*2<br> ~~eee~~|2.5 mm2<br>~~eee~~|4.0 mm2| |**Dimensions**||3.5 × 45 × 30.5<br>~~ee~~|5.2 × 48.8 × 35.3<br>~~ee~~|6.2 × 56.1 × 35.3| |**IEC rated voltage**||500 V<br>~~PO~~|800 V|| |**UL rated voltage**<br>~~Pp~~||600 V<br>~~Pp~~||| |**Dielectric strength**<br>~~Pp~~||1,890 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~Pp~~|2,000 VAC for 1 min<br>(leakage current: 1 mA max.)<br>|| |**End Cover**<br>~~Pp~~||XW5E-P1.5-1.1-1<br>~~Ppes~~|XW5E-P2.5-1.1-1<br>~~es~~|XW5E-P4.0-1.1-1| |**Special tool**||XW4Z-00B||| |**Applicable nameplates**||XW5Z-P1.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness<br>~~ee~~|XW5Z-P2.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness<br>~~ee~~|XW5Z-P4.0LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness| **Note:** Use a conductive DIN Track when using a Grounding Terminal Block. OMRON does not offer conductive DIN Tracks. Please use a commercially available product. *1. For the applicable wire ranges, refer to page 17 for solid and stranded wires and to page 19 for ferrules. - *2. You can also use ferrules for 1.0 to 1.5 mm[2] wires if you use ferrules without insulation sleeve. **9** OmRON ~~a~~ **XW5T** ## **Grounding Terminal blocks Multi tiers terminal** |**Model**|**Model**|**XW5G-P1.5-1.1-2**<br>~~a~~|**XW5G-P2.5-1.1-2**<br>~~a~~|**XW5G-P4.0-1.1-2**| |---|---|---|---|---| |**Appearance and internal**<br>**wiring**<br>~~es~~||2 tiers, 1:1<br>obi|2 tiers, 1:1<br>= —I]<br>~~ee~~|2 tiers, 1:1<br>= “ila<br>~~ee~~| |**Applicable wire sizes*1**|**NOMINAL CROSS**<br>**SECTION**<br>~~a ee~~<br>~~es~~<br>~~a~~|0.75 mm2(1.5 mm2)*2<br>~~ee~~<br>~~ee~~<br>|2.5 mm2<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>|4.0 mm2<br>~~ee~~<br>~~ee~~| ||**Minimum conductor**<br>**cross section solid**<br>~~a ee~~<br>~~es~~<br>~~a~~|0.14 mm2<br>~~ee~~<br>~~ee~~<br>|0.14 mm2<br>~~ee~~<br>~~ee~~<br>~~ee~~<br><br>~~ee~~|0.2 mm2<br>~~ee~~<br>~~ee~~<br>~~ee~~| ||**Maximum conductor**<br>**cross section solid**<br>~~es~~<br>~~a ee~~|1.5 mm2<br>~~ee~~<br>~~ee~~|4.0 mm2<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~|6.0 mm2<br>~~ee~~<br>~~ee~~<br>~~ee~~| ||**Minimum conductor**<br>**cross section fine**<br>**stranded**|0.08 mm2|0.14 mm2<br>~~ee~~|0.2 mm2<br>~~ee~~| ||**Maximum conductor**<br>**cross section fine**<br>**stranded**|1.5 mm2|2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.14 mm2|0.14 mm2|0.25 mm2| ||**Maximum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.75 mm2(1.5 mm2)*2|2.5 mm2|4.0 mm2| |**Dimensions**||3.5 × 65.7 × 41.1<br>~~a~~|5.2 × 78.8 × 45.9<br>~~a~~|6.2 × 85 × 45.9| |**IEC rated voltage**||500 V||| |**UL rated voltage**||600 V||| |**Dielectric strength**||1,890 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~a~~|2,000 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~a~~|| |**End Cover**||XW5E-P1.5-1.1-2<br>~~a~~<br>~~a~~|XW5E-P2.5-1.1-2<br>~~a~~<br>~~a~~|XW5E-P4.0-1.1-2| |**Special tool**||XW4Z-00B||| |**Applicable nameplates**||XW5Z-P1.5LB2|XW5Z-P2.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness|XW5Z-P4.0LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness| **Note:** Use a conductive DIN Track when using a Grounding Terminal Block. OMRON does not offer conductive DIN Tracks. Please use a commercially available product. *1. For the applicable wire ranges, refer to page 17 for solid and stranded wires and to page 19 for ferrules. - *2. You can also use ferrules for 1.0 to 1.5 mm[2] wires if you use ferrules without insulation sleeve. **10** ~~i~~ **XW5T** ## **Grounding Terminal blocks Multi conductor terminals** |**Model**|**Model**|**XW5G-P1.5-1.2-1**<br>~~a~~|**XW5G-P2.5-1.2-1**<br>~~a~~|**XW5G-P4.0-1.2-1**| |---|---|---|---|---| |**Appearance and internal**<br>**wiring**||1 tier, 1:2|1 tier, 1:2|1 tier, 1:2| |**Applicable wire sizes*1**|**NOMINAL CROSS**<br>**SECTION**<br>~~**—**——~~|0.75 mm2(1.5 mm2)*2<br>~~——ee~~|2.5 mm2<br>~~ee~~|4.0 mm2| ||**Minimum conductor**<br>**cross section solid**<br>~~**—**——~~|0.14 mm2<br>~~——ee~~<br>~~oe~~<br>~~—}——~~|0.14 mm2<br>~~ee~~<br>~~—}——~~|0.2 mm2<br>~~—}——~~| ||**Maximum conductor**<br>**cross section solid**<br>~~**—**——~~|1.5 mm2<br>~~——ee~~<br>~~oe~~<br>~~—}——~~|4.0 mm2<br>~~ee~~<br>~~—}——~~|6.0 mm2<br>~~—}——~~| ||**Minimum conductor**<br>**cross section fine**<br>**stranded**<br>~~**—**——~~|0.08 mm2<br>~~—— ee~~<br>~~oe~~<br>~~—}——~~|0.14 mm2<br>~~ee~~<br>~~—}——~~|0.2 mm2<br>~~—}——~~| ||**Maximum conductor**<br>**cross section fine**<br>**stranded**|1.5 mm2<br>~~oe~~<br>~~—}——~~|2.5 mm2<br>~~—}——~~|4.0 mm2<br>~~—}——~~| ||**Minimum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.14 mm2|0.14 mm2|0.25 mm2| ||**Maximum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**|0.75 mm2(1.5 mm2)*2|2.5 mm2|4.0 mm2| |**Dimensions**||3.5 × 54.1 × 30.5<br>~~a~~|5.2 × 60.5 × 35.3<br>~~a~~|6.2 × 66.5 × 35.3| |**IEC rated voltage**||500 V<br>~~OO~~|800 V|| |**UL rated voltage**||600 V<br>~~OO~~<br>~~OO~~|600 V|| |**Dielectric strength**||1,890 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~OO~~|2,000 VAC for 1 min<br>(leakage current: 1 mA max.)|| |**End Cover**||XW5E-P1.5-1.2-1<br>~~a~~|XW5E-P2.5-1.2-1<br>~~a~~|XW5E-P4.0-1.2-1| |**Special tool**||XW4Z-00B||| |**Applicable nameplates**||XW5Z-P1.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness|XW5Z-P2.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness|XW5Z-P4.0LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness| **Note:** Use a conductive DIN Track when using a Grounding Terminal Block. OMRON does not offer conductive DIN Tracks. Please use a commercially available product. *1. For the applicable wire ranges, refer to page 17 for solid and stranded wires and to page 19 for ferrules. *2. You can also use ferrules for 1.0 to 1.5 mm[2] wires if you use ferrules without insulation sleeve. **11** omRON ~~a~~ **XW5T** |**Model**|**Model**|**XW5G-P1.5-2.2-1**<br>~~a~~|**XW5G-P2.5-2.2-1**|**XW5G-P4.0-2.2-1**| |---|---|---|---|---| |**Appearance and internal**<br>**wiring**||1 tier, 2:2<br>Gabe|1 tier, 2:2|1 tier, 2:2| |**Applicable wire sizes*1**|**NOMINAL CROSS**<br>**SECTION**<br>~~a~~|0.75 mm2(1.5 mm2)*2<br>~~a~~<br>~~a~~|2.5 mm2<br>~~a~~|4.0 mm2| ||**Minimum conductor**<br>**cross section solid**<br>~~a~~<br>~~a~~<br>~~a~~|0.14 mm2<br>~~a~~<br>~~a~~<br>~~a~~<br>~~ee~~<br>~~ee~~|0.14 mm2<br>~~a~~<br>~~ee~~|0.2 mm2| ||**Maximum conductor**<br>**cross section solid**<br>~~a~~<br>~~a~~|1.5 mm2<br>~~a~~<br>~~ee~~<br>~~ee~~|4.0 mm2<br>~~ee~~|6.0 mm2| ||**Minimum conductor**<br>**cross section fine**<br>**stranded**<br>~~a~~<br>~~a ~~<br>~~———~~|0.08 mm2<br>~~ee~~<br> ~~eee~~<br>~~———~~|0.14 mm2<br>~~eee~~|0.2 mm2| ||**Maximum conductor**<br>**cross section fine**<br>**stranded**<br>~~———~~|1.5 mm2<br>~~———~~|2.5 mm2|4.0 mm2| ||**Minimum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**<br>~~———~~|0.14 mm2<br>~~———~~|0.14 mm2|0.25 mm2| ||**Maximum conductor**<br>**cross section (flex.,**<br>**stranded) with ferrule**<br>**with Plastic sleeve**<br>~~———~~|0.75 mm2(1.5 mm2)*2<br>~~———~~<br>~~pT~~|2.5 mm2<br>~~pT~~|4.0 mm2| |**Dimensions**||3.5 × 63.2 × 30.5<br>~~pT~~|5.2 × 72.2 × 35.3<br>~~pT~~|6.2 × 76.9 × 35.3| |**IEC rated voltage**||500 V<br>~~PO~~|800 V|| |**UL rated voltage**<br>~~PF~~||600 V<br>~~PF~~||| |**Dielectric strength**<br>~~PF~~||1,890 VAC for 1 min<br>(leakage current: 1 mA max.)<br>~~PF~~|2,000 VAC for 1 min<br>(leakage current: 1 mA max.)<br>|| |**End Cover**<br>~~PF~~||XW5E-P1.5-2.2-1<br>~~PFa~~|XW5E-P2.5-2.2-1<br>~~a~~|XW5E-P4.0-2.2-1| |**Special tool**||XW4Z-00B||| |**Applicable nameplates**||XW5Z-P1.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness<br>~~a~~|XW5Z-P2.5LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness<br>~~a~~|XW5Z-P4.0LB@or commercially available<br>nameplate with 9.5 mm width and 0.5 mm<br>thickness| **Note:** Use a conductive DIN Track when using a Grounding Terminal Block. OMRON does not offer conductive DIN Tracks. Please use a commercially available product. - *1. For the applicable wire ranges, refer to page 17 for solid and stranded wires and to page 19 for ferrules. - *2. You can also use ferrules for 1.0 to 1.5 mm[2] wires if you use ferrules without insulation sleeve. ## **Performance** |**Performance**|| |---|---| |**Operating temperature**|−40 to 55°C (with no condensation or icing)| |**Operating humidity**|5% to 95%| |**Insulating material**|PA resin| |**Fire resistance**|UL94 V-0| |**Insertion durability**|50 times| |**Vibration resistance**|10 to 150 Hz, Acceleration of 50 m/s2for 80 min<br>each in X, Y, and Z directions| |**Shock resistance**|500 m/s2for 11 ms each in 6 directions 5 times| |**Storage Temperature**<br>**Range**|−40 to 85°C (with no condensation or icing)| |**Storage Humidity Range**|5% to 95%| ## **Standards** ## **Compliant standard** - UL1059 - CSA (C22.2 No.158) - IEC 60947-7-1 ## **Certification** - cURus (File No. E245101) ## **Short Bars** |**Model**|**XW5S-P1.5-@**|**XW5S-P2.5-@**|**XW5S-P4.0-@**| |---|---|---|---| |**Rated voltage**|500 V|800 V|| |**Rated current**|17.5 A|24 A|32 A| **12** **XW5T** **Dimensions** **(Unit: mm)** ## **DIN Track Terminal Blocks** ## **XW5T-P1.5-1.1-1 (BL)/XW5G-P1.5-1.1-1** **==> picture [203 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> 3.5<br>45<br>24.5<br>30.5<br>**----- End of picture text -----**<br> **XW5T-P1.5-2.2-1 (BL)/XW5G-P1.5-2.2-1** **==> picture [203 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> 3.5<br>63.2<br>24.5<br>30.5<br>**----- End of picture text -----**<br> ## **XW5T-P2.5-1.1-1 (BL)/XW5G-P2.5-1.1-1** **==> picture [206 x 81] intentionally omitted <==** **----- Start of picture text -----**<br> 5.2<br>48.8<br>29.4<br>35.3<br>**----- End of picture text -----**<br> ## **XW5T-P2.5-2.2-1 (BL)/XW5G-P2.5-2.2-1** **==> picture [9 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> 5.2<br>**----- End of picture text -----**<br> **==> picture [154 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> 72.2<br>29.4<br>35.3<br>**----- End of picture text -----**<br> ## **XW5T-P1.5-1.2-1 (BL)/XW5G-P1.5-1.2-1** **==> picture [203 x 74] intentionally omitted <==** **----- Start of picture text -----**<br> 3.5<br>54.1<br>24.5<br>30.5<br>**----- End of picture text -----**<br> ## **XW5T-P1.5-1.1-2 (BL)/XW5G-P1.5-1.1-2** **==> picture [231 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> 65.7<br>3.5<br>33.7<br>35.1<br>41.1<br>24.5<br>30.5<br>**----- End of picture text -----**<br> ## **XW5T-P2.5-1.2-1 (BL)/XW5G-P2.5-1.2-1** **==> picture [205 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> 5.2<br>60.5<br>29.4<br>35.3<br>**----- End of picture text -----**<br> **XW5T-P2.5-1.1-2 (BL)/XW5G-P2.5-1.1-2** **==> picture [234 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> 5.2<br>78.8<br>40<br>45.9<br>29.4<br>35.3<br>**----- End of picture text -----**<br> **13** **XW5T** **==> picture [512 x 255] intentionally omitted <==** **----- Start of picture text -----**<br> XW5T-P4.0-1.1-1 (BL)/XW5G-P4.0-1.1-1 XW5T-P4.0-1.2-1 (BL)/XW5G-P4.0-1.2-1<br>6.2 6.2<br>56.1 66.5<br>29.4 29.4<br>35.3 35.3<br>XW5T-P4.0-2.2-1 (BL)/XW5G-P4.0-2.2-1 XW5T-P4.0-1.1-2 (BL)/XW5G-P4.0-1.1-2<br>6.2<br>85<br>6.2<br>76.9<br>40<br>45.9<br>29.4 29.4<br>35.3 35.3<br>**----- End of picture text -----**<br> ## **Short Bars** **==> picture [512 x 410] intentionally omitted <==** **----- Start of picture text -----**<br> XW5S-P1.5- @<br>3.5×(No. of poles-1)+2.3<br>3<br>Model P (mm)<br>XW5S-P1.5-2 @ 3.5<br>18.2 XW5S-P1.5-3 @ 7.0<br>XW5S-P1.5-4 @ 10.5<br>XW5S-P1.5-5 @ 14.0<br>XW5S-P1.5-10 @ 31.5<br>1.6<br>3.5<br>P<br>XW5S-P2.5- @<br>5.2×(No. of poles-1)+3.7 3<br>Model P (mm)<br>XW5S-P2.5-2 @ 5.2<br>XW5S-P2.5-3 @ 10.4<br>23<br>XW5S-P2.5-4 @ 15.6<br>XW5S-P2.5-5 @ 20.8<br>XW5S-P2.5-10 @ 46.8<br>1.6<br>5.2<br>P<br>XW5S-P4.0- @<br>6.2×(No. of poles-1)+4.4 3<br>Model P (mm)<br>XW5S-P4.0-2 @ 6.2<br>XW5S-P4.0-3 @ 12.4<br>23<br>XW5S-P4.0-4 @ 18.6<br>XW5S-P4.0-5 @ 24.8<br>XW5S-P4.0-10 @ 55.8<br>1.6<br>6.2<br>P<br>**----- End of picture text -----**<br> **14** **XW5T** ## **End Cover** ## **XW5E-P1.5-1.1-1** ## **XW5E-P1.5-1.2-1** **==> picture [215 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> 2.2<br>45<br>24.5<br>2.2<br>63.2<br>24.5<br>**----- End of picture text -----**<br> **XW5E-P1.5-2.2-1** **==> picture [215 x 190] intentionally omitted <==** **----- Start of picture text -----**<br> 2.2<br>54.1<br>24.5<br>2.2<br>65.4<br>35.1<br>**----- End of picture text -----**<br> ## **XW5E-P1.5-1.1-2** ## **XW5E-P2.5-1.1-1** **XW5E-P2.5-1.2-1** **==> picture [511 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> 2.2 2.2<br>48.8 60.5<br>29.4 29.2<br>XW5E-P2.5-2.2-1 XW5E-P2.5-1.1-2<br>**----- End of picture text -----**<br> **==> picture [214 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> 2.2<br>72.2<br>29.2<br>**----- End of picture text -----**<br> **==> picture [214 x 96] intentionally omitted <==** **----- Start of picture text -----**<br> 2.2<br>78.8<br>39.8<br>**----- End of picture text -----**<br> **15** **XW5T** **==> picture [512 x 246] intentionally omitted <==** **----- Start of picture text -----**<br> XW5E-P4.0-1.1-1 XW5E-P4.0-1.2-1<br>2.2 66.5 2.2<br>56.1<br>29.4 29.2<br>XW5E-P4.0-2.2-1 XW5E-P4.0-1.1-2<br>2.2<br>85<br>76.9 2.2<br>39.8<br>29.2<br>**----- End of picture text -----**<br> ## **End Brackets/Separator Plates** **==> picture [512 x 185] intentionally omitted <==** **----- Start of picture text -----**<br> XW5Z-EP6 (End Brackets) XW5Z-EP12 (Separator Plates)<br>56 12<br>55 6<br>33.5<br>40.2<br>63<br>**----- End of picture text -----**<br> **16** **XW5T** ## **Safety Precautions** ## **Warning Indications** |**Precautions**<br>**for Safe Use**|**Supplementary comments on what to do or**<br>**avoid doing, to use the product safely.**| |---|---| |**Precautions**<br>**for Correct**<br>**Use**|**Supplementary comments on what to do or**<br>**avoid doing, to prevent failure to operate,**<br>**malfunction, or undesirable effects on**<br>**product performance.**| ## **Precautions for Correct Use** ## **1. Precautions for Correct Use** - Always mount End Covers to the following locations when you use Terminal Blocks. - Exposed metal surface of the last Terminal Block - Any Terminal Block that is next to a different shape of Terminal Block - There is a risk of electric shock if End Covers are not used. ## **Precautions for Safe Use** - Do not drop the Terminal Block. Terminal Block functionality may be inhibited. - Do not exceed the ratings. Doing so may damage or burn out the Terminal Block. - Mount the Terminal Blocks on a DIN Track and secure both ends with Stoppers. - Do not use the Terminal Block in locations where toxic gases, such as H2S, SO2, NH3, HNO3, and Cl2, may be present, or in locations subject to high temperature or humidity. Doing so may damage the Terminal Block due to contact failure or corrosion. - Do not use the Terminal Block submersed in oil or water, or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering and damaging the Terminal Block. - Do not use or keep the Terminal Block under the following conditions: - When you wire the Terminal Block, do not subject it or the wires to stress. Secure the wires so that they do not resonate with vibrations from the facilities in installation conditions. - Always turn OFF the power supply before wiring. Electrical shock may occur. ## **2. Connecting Wires to the Push-In Plus Terminal Block** ## **Part Names of the Terminal Block** **==> picture [76 x 27] intentionally omitted <==** **----- Start of picture text -----**<br> Release hole<br>Terminal (Insertion) hole<br>**----- End of picture text -----**<br> - Subject to severe temperature changes. - Subject to high humidity or condensation. - Subject to severe vibration or shock. - Where direct rays of the sun strike. - Where sea breeze may be present. - Do not wire anything to the release holes. - Do not tilt or twist a flat-blade screwdriver while it is inserted into a release hole on the terminal block. The terminal block may be damaged. ## **Connecting Wires with Ferrules and Solid Wires** Insert the solid wire or ferrule straight into the terminal block until the end strikes the terminal block. If a wire is difficult to connect because it is too thin, use a flat-blade screwdriver in the same way as when connecting stranded wire. - Insert a flat-blade screwdriver into the release holes at an angle. The terminal block may be damaged if you insert the screwdriver straight in. - Do not allow the flat-blade screwdriver to fall out while it is inserted into a release hole. - Do not bend a wire past its natural bending radius or pull on it with excessive force. Doing so may cause the wire disconnection. Do not place excessive force on a Terminal Block. Doing so may damage or deform the Terminal Block and result in contact failure. **==> picture [62 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Ferrule or solid wire<br>**----- End of picture text -----**<br> **==> picture [77 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal (Insertion) hole<br>**----- End of picture text -----**<br> - Do not insert more than one wire into each terminal insertion hole. - If you mount more than one Terminal Block, mount them so that the conductive parts of adjacent Terminal Blocks are facing in the same direction. If they face in different directions, short circuits may occur between adjacent Terminal Blocks. - To prevent wire materials from smoking or igniting, confirm wire ratings and use the wiring materials given in the following table. ||**Recommended Wire**|**Recommended Wire**|**Stripping length**<br>**(Without Ferrules)**| |---|---|---|---| ||**Solid**|**Stranded**|| |XW5T-P1.5-@<br>XW5G-P1.5-@|0.14 to 1.5 mm2/<br>AWG 26 to 14|0.14 to 1.5 mm2/<br>AWG 28 to 16|8 mm| |XW5T-P2.5-@<br>XW5G-P2.5-@|0.14 to 4.0 mm2/<br>AWG 26 to 12|0.14 to 2.5 mm2/<br>AWG 26 to 14|10 mm| |XW5T-P4.0-@<br>XW5G-P4.0-@|0.25 to 6.0 mm2/<br>AWG 24 to 10|0.25 to 4.0 mm2/<br>AWG 24 to 12|12 mm| **17** ## **XW5T** ## **Connecting Stranded Wires** Use the following procedure to connect the wires to the terminal block. **1.** Hold a flat-blade screwdriver at an angle and insert it into the release hole. The angle should be between 10° and 15°. If the flat-blade screwdriver is inserted correctly, you will feel the spring in the release hole. **2.** With the flat-blade screwdriver still inserted into the release hole, insert the wire into the terminal hole until it strikes the terminal block. **3.** Remove the flat-blade screwdriver from the release hole. ## **3. Removing Wires from the Push-In Plus Terminal Block** Use the following procedure to remove wires from the terminal block. The same method is used to remove stranded wires, solid wires, and ferrules. **1.** Hold a flat-blade screwdriver at an angle and insert it into the release hole. **2.** With the flat-blade screwdriver still inserted into the release hole, remove the wire from the terminal insertion hole. **3.** Remove the flat-blade screwdriver from the release hole. **==> picture [167 x 87] intentionally omitted <==** **----- Start of picture text -----**<br> 10 to 15°<br>Flat-blade screwdriver Wire<br>2<br>3<br>1<br>**----- End of picture text -----**<br> **==> picture [168 x 88] intentionally omitted <==** **----- Start of picture text -----**<br> 10 to 15°<br>Flat-blade screwdriver Wire<br>2<br>3<br>1<br>**----- End of picture text -----**<br> ## **Checking Connections** - After the insertion, pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal block. - If you use a ferrule with a conductor length of 10 mm, part of the conductor may be visible after the ferrule is inserted into the terminal block, but the product insulation distance will still be satisfied. **18** **XW5T** ## **4. Recommended Ferrules and Crimp Tools Recommended ferrules XW5T-P1.5- @ - @@ /XW5G- @ P1.5- @ - @@** |**Applicable wire**|**Applicable wire**|**Ferrule**<br>**Conductor**<br>**length**<br>**(mm)**|**Stripping**<br>**length**<br>**(mm)**<br>**(Ferrules used)**|**Recommended ferrules**|**Recommended ferrules**|**Recommended ferrules**| |---|---|---|---|---|---|---| |**(mm2)**|**(AWG)**|||**Manufactured by**<br>**Phoenix Contact**|**Manufactured**<br>**by Weidmuller**|**Manufactured by**<br>**Wago**| |0.14|26|8|10|AI 0,14-8|H0.14/12|---| |0.25|24|8|10|AI 0,25-8|H0.25/12|216-301| |||10|12|AI 0,25-10|---|---| |0.34|22|8|10|AI 0,34-8|H0.34/12|216-302| |||10|12|AI 0,34-10|---|---| |0.50|20|8|10|AI 0,5-8|H0.5/14|216-201| |||10|12|AI 0,5-10|H0.5/16|216-241| |0.75|18|8|10|AI 0,75-8|H0.75/14|216-202| |||10|12|AI 0,75-10|H0.75/16|216-242| |Recommended crimp tool||||CRIMPFOX6<br>CRIMPFOX6T-F<br>CRIMPFOX10S|PZ6 roto|Variocrimp4| - **Note: 1.** Make sure that the outer diameter of the wire is smaller than the inner diameter of the insulation sleeve of the recommended ferrule. **2.** Make sure that the ferrule processing dimensions conform to the following figure. Ferrule Processed Dimensions 8 to 10 mm ## 2.1 mm max. ## 2.5 mm max. **3.** For the ferrule which is for applicable wire (1 to 1.5 mm[2] / AWG 18 to 16), please use a ferrule without an insulation sleeve. (Refer to the following table.) |**Applicable wire**|**Applicable wire**|**Ferrule**<br>**Conductor**<br>**length**<br>**(mm)**|**Stripping**<br>**length**<br>**(mm)**<br>**(Ferrules used)**|**Recommended ferrules**|**Recommended ferrules**|**Recommended ferrules**| |---|---|---|---|---|---|---| |**(mm2)**|**(AWG)**|||**Manufactured by**<br>**Phoenix Contact**|**Manufactured**<br>**by Weidmuller**|**Manufactured by**<br>**Wago**| |1/1.25|18/17|8|8|A 1-8|---|F-1.0-8| |||10|10|A 1-10|H1,0/10|F-1.0-10| |1.25/1.5|17/16|10|10|A 1,5-10|H1,5/10|F-1.5-10| |Recommended crimp tools||||CRIMPFOX6<br>CRIMPFOX6T-F<br>CRIMPFOX10S|PZ6 roto|Variocrimp4| ## **XW5T-P2.5- @ - @@ /XW5G- @ P2.5- @ - @@** |**Applicable wire**|**Applicable wire**|**Ferrule**<br>**Conductor**<br>**length**<br>**(mm)**|**Stripping**<br>**length**<br>**(mm)**<br>**(Ferrules used)**|**Recommended ferrules**|**Recommended ferrules**|**Recommended ferrules**| |---|---|---|---|---|---|---| |**(mm2)**|**(AWG)**|||**Manufactured by**<br>**Phoenix Contact**|**Manufactured**<br>**by Weidmuller**|**Manufactured by**<br>**Wago**| |0.14|26|8|10|AI 0,14-8|H0.14/12|---| |0.25|24|8|10|AI 0,25-8|H0.25/12|216-301| |||10|12|AI 0,25-10|---|---| |0.34|22|8|10|AI 0,34-8|H0.34/12|216-302| |||10|12|AI 0,34-10|---|---| |0.50|20|8|10|AI 0,5-8|H0.5/14|216-201| |||10|12|AI 0,5-10|H0.5/16|216-241| |0.75|18|8|10|AI 0,75-8|H0.75/14|216-202| |||10|12|AI 0,75-10|H0.75/16|216-242| |1/1.25|18/17|8|10|AI 1-8|H1.0/14|216-203| |||10|12|AI 1-10|H1.0/16|216-243| |1.25/1.5|17/16|8|10|AI 1,5-8|H1.5/14|216-204| |||10|12|AI 1,5-10|H1.5/16|216-244| |2.5|14|10|12|AI 2,5-10|H2.5/16DS|216-246| |Recommended crimp tool||||CRIMPFOX6<br>CRIMPFOX6T-F<br>CRIMPFOX10S|PZ6 roto|Variocrimp4| - **Note: 1.** Make sure that the outer diameter of the wire is smaller than the inner diameter of the insulation sleeve of the recommended ferrule. **2.** Make sure that the ferrule processing dimensions conform to the following figure. Ferrule Processed Dimensions 8 to 10 mm 2.6 mm max. 2.8 mm max. ## **XW5T-P4.0- @ - @@ /XW5G- @ P4.0- @ - @@** |**Applicable wire**|**Applicable wire**|**Ferrule**<br>**Conductor**<br>**length**<br>**(mm)**|**Stripping**<br>**length**<br>**(mm)**<br>**(Ferrules used)**|**Recommended ferrules**|**Recommended ferrules**|**Recommended ferrules**| |---|---|---|---|---|---|---| |**(mm2)**|**(AWG)**|||**Manufactured by**<br>**Phoenix Contact**|<br>**Manufactured**<br>**by Weidmuller**|**Manufactured by**<br>**Wago**| |0.25|24|12|14|AI 0,25-12|---|---| |0.34|22|||AI 0,34-12|---|---| |0.50|20|||AI 0,5-12|---|216-261| |0.75|18|||AI 0,75-12|H0.75/18|216-262| |1/1.25|18/17|||AI 1-12|H1.0/18|216-263| |1.25/1.5|17/16|||AI 1,5-12|H1.5/18D|216-264| |2.5|14|||AI 2,5-12|H2.5/19D|216-266| |4|12|||AI 4-12|H4.0/20D|216-267| |Recommended crimp tool||||CRIMPFOX6<br>CRIMPFOX6T-F<br>CRIMPFOX10S|PZ6 roto|Variocrimp4| - **Note: 1.** Make sure that the outer diameter of the wire is smaller than the inner diameter of the insulation sleeve of the recommended ferrule. **2.** Make sure that the ferrule processing dimensions conform to the following figure. Ferrule Processed Dimensions 12 mm 3.2 mm max. 3 mm max. ## **Recommended Flat-blade Screwdriver** Use a flat-blade screwdriver to connect and remove wires. Use the following flat-blade screwdriver. The following table shows manufacturers and models as of 2015/Dec. **==> picture [127 x 73] intentionally omitted <==** **----- Start of picture text -----**<br> Side Front<br>2.5 mm dia.<br>0.4 mm 2.5 mm<br>**----- End of picture text -----**<br> |**Model**|**Manufacturer**| |---|---| |ESD 0,40×2,5|Wera| |SZS 0,4×2,5<br>SZF 0-0,4×2,5*|Phoenix Contact| |0.4×2.5×75 302|Wiha| |AEF.2,5×75|Facom| |210-719|Wago| |SDIS 0.4×2.5×75|Weidmuller| |9900 (-2.5×75)|Vessel| - OMRON's exclusive purchase model XW4Z-00B is available to order as SZF 0-0,4×2,5 (manufactured by Phoenix Contact). **19** **XW5T** ## **Equivalent Labels from Other Companies and Recommended Label Printers** Use the following label printer. The following table gives the manufacturer’s model number as of March 2017. |**Manufacturer**|**Omron**|**Phoenix**<br>**Contact**|**Weidmuller**|**Cembre**| |---|---|---|---|---| |Label|XW5Z-P1.5LB1|UCT-TM3,5|NA|MG-CPM-04<br>41392| ||XW5Z-P2.5LB1|UCT-TM5|MF 8/5|MG-CPM-04<br>41390N| ||||MF 10/5|| ||||MF 12/5|| ||XW5Z-P4.0LB1|UCT-TM6|MF 10/6|MG-CPM-04<br>41391| ||XW5Z-P1.5LB2|UCT-TMF3,5|---|---| ||XW5Z-P2.5LB2|UCT-TMF5|---|---| ||XW5Z-P4.0LB2|UCT-TMF6|---|---| |Label printer|---*|BLUEMARK<br>CLED,<br>THERMOMA<br>RK CARD<br>SET PLUS,<br>THERMOMA<br>RK CARD|PrintJet<br>ADVCANCED,<br>Plotter MCP<br>Plus,<br>Plotter MCP<br>Basic|Markingenius<br>MG3| ## **6. Using the Accessories Short Bars Mounting Method** **1.** Insert the Short Bar into the Short Bar holes. **2.** Press the Short Bar in all of the way. ## **Removal Method** * When using a printing tool, use a Phoenix Contact label printer. **Note:** Ask the label manufacturer or printer manufacturer for details. ## **5. Mounting to DIN Track/Removing from DIN Track Mounting Method** To mount a Terminal Block to a DIN Track, press it against the DIN Track as shown in the following figure. **1.** Insert the tip of a flat-blade screwdriver into the groove on the Short Bar and lift it up. **2.** Remove the Short Bar. ## **Removal Method** To remove a Terminal Block from the DIN Track, catch the tip of a screwdriver in the hook, operate the screwdriver so that the tip moves in direction (1), and then remove the Terminal Block in direction (2). However, do not apply excessive force to the Terminal Block. Doing so may damage it. **==> picture [113 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> (2)<br>(1)<br>as.»<br>**----- End of picture text -----**<br> **20** **XW5T** ## **Installation** ## **Side-surface Labels** You can bend and cut off any of the middle pins with a tool when you use a Short Bar. Bend. Cut. If a Short Bar that has the required pins is not available, you can combine more than one Short Bar to short the required Terminal Blocks. For example, the following figure shows combining Four-pin and Fivepin Short Bars to short eight Terminal Blocks. **==> picture [85 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Shorting 8 Terminal Blocks.<br>**----- End of picture text -----**<br> **1.** Remove the Labels one at a time. **2.** Insert them on the sides of the Terminal Blocks. - **Note: 1.** There is no place to mount the Top-surface Labels on Twotier Terminal Blocks with a width of 3.5 mm, so they cannot be used. **2.** Different models of Labels are used for the top and side surfaces. **3.** If multiple Terminal Blocks of the same type are used side by side, you can use multiple Labels still connected to each other. ## **End Cover** Four-pin Short Bar Five-pin Short Bar ## **Labels Mounting Method Top-surface Labels** ## **Mounting Method** Attach the End Cover to the side of the Terminal Block with exposed metal. **==> picture [47 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal Block<br>**----- End of picture text -----**<br> **==> picture [71 x 21] intentionally omitted <==** **----- Start of picture text -----**<br> End Cover ion<br>**----- End of picture text -----**<br> Always mount End Covers to the following locations when you use Terminal Blocks. - (1) Exposed metal surface of the last Terminal Block (2) Any Terminal Block that is next to a different shape of Terminal Block There is a risk of electric shock if End Covers are not used. **1.** Remove the Labels one at a time. **==> picture [9 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> (2)<br>**----- End of picture text -----**<br> **2.** Insert them on the tops of the Terminal Blocks. **Note:** If multiple Terminal Blocks of the same type are used side by side, you can use multiple Labels still connected to each other. **==> picture [10 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> (1)<br>**----- End of picture text -----**<br> **Note:** End Brackets or Separator Plate cannot be used in place of an End Cover. **21** **XW5T** ## **End Brackets** ## **Mounting Method** The mounting and removal methods for DIN Track are the same as those for the Terminal Blocks. ## **Separator Plate** ## **Mounting Method** Use a flat-blade screwdriver to tighten the screw in the middle of the top surface to mount the Separator Plate. Loosen the screw to remove the Separator Plate from the DIN Track. M4 Screw i <a cg ## **7. Storage** ## **Storage Temperature Range** − 40 to 85°C with no condensation or icing **Storage Humidity Range** 5% to 95% **22** ## **Terms and Conditions Agreement** ## **Read and understand this catalog.** Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. ## **Warranties.** (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. ## **Limitation on Liability; Etc.** OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. ## **Suitability of Use.** Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. ## **Programmable Products.** Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. ## **Performance Data.** Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. ## **Change in Specifications.** Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. ## **Errors and Omissions.** Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. ## **OMRON Corporation Industrial Automation Company** **Kyoto, JAPAN** **Contact: www.ia.omron.com** _**Regional Headquarters**_ **OMRON ELECTRONICS LLC** **OMRON EUROPE B.V.** Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 **OMRON (CHINA) CO., LTD.** Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 **OMRON ASIA PACIFIC PTE. LTD.** No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 **==> picture [185 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> Authorized Distributor:<br>**----- End of picture text -----**<br> © OMRON Corporation 2016-2017 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. **CSM_1_16_0919 Cat. No. G124-E1-03** 0317(0316)
Updated at April 15, 2026
With a legacy spanning over 80 years, Omron Industrial Automation is a globally recognized leader in the manufacture of advanced industrial control and automation components. Renowned for their reliability and engineering excellence, Omron delivers comprehensive solutions that enhance efficiency, machine safety, and precision across a wide range of manufacturing environments. Our extensive portfolio of Omron products is heavily focused on their industry-leading sensing and switching technologies. We offer a vast selection of sensors, excelling specifically in high-performance proximity sensors, light sensors, and temperature sensors. Complementing this range are robust switching solutions, featuring a deep inventory of power relays, solid-state relays, safety relays, and essential relay accessories designed for demanding operational requirements. Beyond sensing and switching, Omron is highly regarded for its precision automation and process control equipment. Our selection features highly accurate temperature controllers, versatile process controllers, and sophisticated panel displays and instrumentation. To support these fundamental systems, we also supply dependable Omron power supplies, notably AC/DC converters, alongside vital connectivity components like DIN rail terminal blocks to ensure secure, efficient, and complete industrial setups.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →