- Manufacturer: TELEMECANIQUE SENSORS
- Product type:
- Sensor Output:Relay; Sensing Range Max:30m; Supply Voltage DC Min:24V; Supply Voltage DC Max:240V; Output Current:3A; Product Range:OsiSense XUK Series; Supply Voltage AC Max:240
- IP Rating: IP65
- Output Type: Digital - NO / NC
- Sensor Type: Photoelectric Sensor
- Light Source: Infrared, Polarised Red LED
- Product Range: XU Series
- Qualification: -
- Sensing Method: Multimode
- Connection Method: 2m 5 Wire Cable
- Sensing Range Max: 30m
- Sensor Output Type: Relay
- Supply Voltage Max: 264V
- Supply Voltage Min: 20V
- Sensing Distance Max: 35m
- Supply Voltage DC Max: 240V
- Supply Voltage DC Min: 24V
- Operating Temperature Max: 55°C
- Operating Temperature Min: -25°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 139.43 € |
| Current stock | 10+ |
| Lead time | 30 days |
Product data sheet Characteristics Photoelectric sensors XU, XUK, multi, Sn 0...30 m, 24...240VAC/DC, cable 2 m ## XUK0ARCTL2 ## Main ||Main| |---|---| ||Range of product<br>Telemecanique Photoelectric sensors XU| ||Series name<br>General purpose multimode| ||Electronic sensor type<br>Photo-electric sensor| ||Sensor name<br>XUK| ||Sensor design<br>Compact 50 x 50| ||Detection system<br>Multimode| ||Material<br>Plastic| ||Type of output signal<br>Discrete| ||Supply circuit type<br>AC/DC| ||Wiring technique<br>5-wire| |Complementary<br>Enclosure material<br>Lens material<br>Maximum sensing distance<br>Output type<br>Add on output<br>Wire insulation material<br>Status LED<br>[Us] rated supply voltage<br>Supply voltage limits<br>Switching capacity in mA<br>Switching frequency<br>Maximum voltage drop<br>Maximum power consumption in W<br>Time delay range<br>Maximum delay first up<br>Maximum delay response<br>Maximum delay recovery<br>Setting-up<br>Electrical durability|Discrete output function<br>1 NO or 1 NC programmable<br>Electrical connection<br>Cable<br>Cable length<br>2 m<br>Product specific<br>application<br>-<br>Emission<br>Infrared diffuse<br>Infrared diffuse with background suppression<br>Infrared thru beam<br>Red polarised reflex<br>[Sn] nominal sensing<br>distance<br>4 M polarised reflex need reflector XUZC50<br>30 M thru beam need a transmitter XUK0ARCTL2T<br>0.28 M diffuse with background suppression<br>0.8 m diffuse<br>PBT<br>PMMA<br>35 M thru beam<br>0.28 M diffuse with background suppression<br>1.2 M diffuse<br>5.7 m polarised reflex<br>Relay<br>Without, <= 50 mA with overload and short-circuit protection<br>PvR<br>1 LED (green) for supply<br>1 LED (red) for instability<br>1 LED (yellow) for output state<br>24...240 V AC<br>24...240 V DC<br>20…264 V AC<br>20…264 V DC<br>3 A (cos φ = 1 for 0.5 million cycles at 1 operating cycle per second at 250 V)<br><= 20 Hz<br><1.5 V (closed state)<br>3 W AC/DC<br>0...10 s monostable, on-delay or off-delay (programmable) delay<br>300 ms<br>25 ms<br>25 ms<br>Self-teaching<br>500000 cycles, cos f = 1, operating rate <60 cyc/mn at 250 V| ## Complementary Sep 27, 2024 1 **==> picture [236 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Depth|50 mm| |Height|50 mm| |Width|18 mm| |Net weight|0.175 kg| **----- End of picture text -----**<br> ## Environment **==> picture [469 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Product certifications|CE[RETURN]UL[RETURN]CSA| |Ambient air temperature for operation|-25…55 °C| |Ambient air temperature for storage|-40…70 °C| |Vibration resistance|7 gn, amplitude = +/- 1.5 mm (f = 10…55 Hz) conforming to IEC 60068-2-6| |Shock resistance|30 gn (duration = 11 ms) conforming to IEC 60068-2-27| |IP degree of protection|IP65 double insulation conforming to IEC 60529| **----- End of picture text -----**<br> ## Packing Units **==> picture [236 x 244] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Unit Type of Package 1|PCE| |Number of Units in Package 1|1| |Package 1 Height|4.2 cm| |Package 1 Width|9.7 cm| |Package 1 Length|13.2 cm| |Package 1 Weight|180.0 g| |Unit Type of Package 2|S02| |Number of Units in Package 2|22| |Package 2 Height|15.0 cm| |Package 2 Width|30.0 cm| |Package 2 Length|40.0 cm| |Package 2 Weight|4.539 kg| |Unit Type of Package 3|P06| |Number of Units in Package 3|352| |Package 3 Height|80.0 cm| |Package 3 Width|80.0 cm| |Package 3 Length|60.0 cm| |Package 3 Weight|79.14 kg| **----- End of picture text -----**<br> ## Offer Sustainability **==> picture [476 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Sustainable offer status|Green Premium product| |California proposition 65|WARNING: This product can expose you to chemicals including: Diisononyl| |phthalate (DINP), which is known to the State of California to cause cancer,| |and Di-isodecyl phthalate (DIDP), which is known to the State of California| |to cause birth defects or other reproductive harm. For more information go to| |www.P65Warnings.ca.gov| |For all Reach Rohs enquiries contact us at|sustainability@tesensors.com| **----- End of picture text -----**<br> ## Contractual warranty Warranty 18 months 2
Updated at June 8, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →