Photoelectric Sensor, OsiSense XU Series, M18, 15 m, PNP, 12 V to 24 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TELEMECANIQUE SENSORS
- Product type:
- Sensing Range Max:15m; Sensing Method:Diffuse Reflective; Sensor Output:PNP; Product Range:-; Connection Method:Cable; Supply Voltage DC Min:12V; Supply Voltage DC Max:24V; Body Length:64m
- Product Range: XU Series
- Sensing Method: Diffuse Reflective
- Connection Method: Cable
- Operating Temperature Max: 55°C
- Operating Temperature Min: -15°C
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 85.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
**1** ## Photo-electric sensors ## Osiris[®] optimum sensors Plastic case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output Accessories : pages 1/154 to 1/159 ## References, characteristics ## Design 18 **==> picture [365 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3<br>**----- End of picture text -----**<br> |**System**||**Thru-beam1**|**Reflex2**|**Polarised reflex2**|**Diffuse3**| |---|---|---|---|---|---| |**Type of transmission**||Infra-red|Infra-red|Red|Infra-red| |**Nominal sensing distance**(Sn)||**15 m**|**4 m **(with 50 x 50 mm|**1.5 m **(with 50 x 50 mm|**0.10 m**| ||||reflector)|reflector)|| |References of pre-cabled versions|||||| ||Line of sight||||| |3-wire, PNP|along case axis|**XU2-P18PP340**(1)|**XU1-P18PP340**(2)|**XU9-P18PP340**(2)|**XU5-P18PP340**| |Light or dark program-|Line of sight||||| |mable switching|90°to case axis|**XU2-P18PP340W**(1)|**XU1-P18PP340W**(2)|**XU9-P18PP340W**(2)|**XU5-P18PP340W**| ||Line of sight||||| |3-wire, NPN|along case axis|**XU2-P18NP340**(1)|**XU1-P18NP340**(2)|**XU9-P18NP340**(2)|**XU5-P18NP340**| |Light or dark program-|Line of sight||||| |mable switching|90°to case axis|**XU2-P18NP340W**(1)|**XU1-P18NP340W**(2)|**XU9-P18NP340W**(2)|**XU5-P18NP340W**| |Weight (kg)||0.220|0.130|0.130|0.110| ## References of plug-in connector versions ||Line of sight||||| |---|---|---|---|---|---| |3-wire, PNP|along case axis|**XU2-P18PP340D**(1)|**XU1-P18PP340D**(2)|**XU9-P18PP340D**(2)|**XU5-P18PP340D**| |Light or dark program-|Line of sight||||| |mable switching|90°to case axis|**XU2-P18PP340WD**(1)|**XU1-P18PP340WD**(2)|**XU9-P18PP340WD**(2)|**XU5-P18PP340WD**| ||Line of sight||||| |3-wire, NPN|along case axis|**XU2-P18NP340D**(1)|**XU1-P18NP340D**(2)|**XU9-P18NP340D**(2)|**XU5-P18NP340D**| |Light or dark program-|Line of sight||||| |mable switching|90°to case axis|**XU2-P18NP340WD**(1)|**XU1-P18NP340WD**(2)|**XU9-P18NP340WD**(2)|**XU5-P18NP340WD**| |Weight (kg)||0.080|0.060|0.060|0.040| Complementary characteristics not shown under general characteristics (page 1/17) |**Connection**<br>Pre-cabled|Diameter 5 mm cable, length 2 m (3), wire c.s.a. : 4 x 0.34 mm2| |---|---| |Connector|M12 male connector, 4-pin (suitable female connectors (pre-wired and screw terminal) types 3, 4 & 5, see page 1/160)| |**Materials**|Case : PPS, lenses : PMMA, cable : PVC| |**Rated supply voltage**|**a 12…24 V with protection against reverse polarity**| |**Voltage limits**|a10…30 V (including ripple)| |**Switching capacity**(sealed)|≤ **100 mA with overload and short-circuit protection**| |**Voltage drop, closed state**|≤1.5 V| |**Current consumption, no-load**|≤30 mA (reflex and diffuse),≤50 mA (thru-beam)| |**Maximum switching frequency**|500 Hz| |**Delays**|First-up :≤15 ms ; response :≤1 ms ; recovery :≤1 ms| (1) Reference for both transmitter and receiver for thru-beam system sensors. (2) 50 x 50 mm reflector included with reflex and polarised reflex system sensors. (3) Sensors available with 5 m cable. To order, add the suffix **L5** to the reference selected from above. Example : sensor **XU1-P18PP340** with 5 m cable becomes **XU1-P18PP340L5** . > 1/18 Te **1** ## Photo-electric sensors ## Osiris[®] optimum sensors Plastic case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output Accessories : pages 1/154 to 1/159 ## Curves, dimensions, schemes ## **Detection curves** **==> picture [358 x 88] intentionally omitted <==** **----- Start of picture text -----**<br> Thru-beam system Reflex system Polarised reflex system<br>Ø of beam Ø of beam Ø of beam<br>cm cm cm<br>10 6<br>15 4<br>T Ø 12 mm R T/R 4 T/R 2<br>10 15 m -4 2 4 m -2 0,2 1,5 2 m<br>-15 -10 -4<br>-6<br>Sn ≤ 15 m Sn ≤ 4 m Sn ≤ 1,5 m n ≤ 1,5 m ≤ 1,5 m 1,5 m ,5 m m<br>**----- End of picture text -----**<br> **==> picture [257 x 270] intentionally omitted <==** **----- Start of picture text -----**<br> Polarised reflex system Diffuse system<br>Ø of beam Ø of beam<br>cm cm<br>6 T/R 1,4<br>4 1<br>T/R 2 2 1<br>-2 0,2 1,5 2 m 10 cm<br>-4 -1<br>-6 -1,4<br>Sn ≤ 1,5 m n ≤ 1,5 m ≤ 1,5 m 1,5 m ,5 m m Sn ≤ 0,10 m<br>With reflector XUZ-C50 Object 10 x 10 cm<br>1 White 90%<br>2 Grey 18%<br>Polarised reflex system Diffuse system<br>gain gain<br>10<br>50<br>30<br>20<br>15<br>1 10<br>7<br>5<br>3<br>2<br>0,1 1<br>0,1 0,5 1 1,5 3 5 0,1 0,2 0,5 1 2 5 10 20 60<br>D (m) D (cm)<br>With reflector XUZ-C50 Object 10 x 10 cm<br>White 90%<br>**----- End of picture text -----**<br> With reflector XUZ-C50 **==> picture [262 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> Excess gain curves (ambient temperature : + 25 °C)<br>Thru-beam system Reflex system<br>gain gain<br>100 100<br>80<br>50<br>20<br>30<br>20 10<br>10<br>8<br>5 1<br>3<br>2<br>1 0,1<br>1 2 3 4 5 6 8 10 15 20 30 50 0,1 0,2 0,5 1 4 5 10<br>D (m) D (m)<br>With reflector XUZ-C50<br>**----- End of picture text -----**<br> **==> picture [523 x 387] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>XU i -P18 ii 340 XU i -P18 ii 340W<br>4 4<br>M18x1 (1) M18x1 (1)<br>Ø5 Ø5<br>50 24 50 24<br>62 (2) 78<br>XU i -P18 ii 340D XU i -P18 ii 340WD<br>4 4<br>M18x1 (1) M18x1 (1)<br>50 24 50 24<br>62 62<br>72 (3) 88<br>(1) LED Fixing nut tightening torque : < 15 N.m<br>(2) 64 for XU9-P18 ii 340 Connector tightening torque : 2 N.m<br>(3) 74 for XU9-P18 ii 340D<br>Cable connections Connector schemes (sensor connector pin view )<br>Transmitter Thru-beam receiver,<br>- (–) BU (Blue) reflex and diffuse<br>- (+) BN (Brown) 1 (+) 1 (+)<br>-- (OUT)(Prog.) OGBK (Orange)(Black) 2 4 2 4<br>- (Test) VI (Violet) for thru-beamtransmitter only Test 3 (–) Program-ming 3 (–) Output<br>Beam break test (for thru-beam transmitter only)<br>Beam made Beam broken<br>BN/1 + BN/1 +<br>VI/2 VI/2<br>BU/3 – BU/3 –<br>**----- End of picture text -----**<br> Te 1/19 **1** ## Photo-electric sensors ## Osiris[®] optimum sensors Metal case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output Accessories : pages 1/154 to 1/159 ## References, characteristics ## Design 18 **==> picture [365 x 99] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3<br>**----- End of picture text -----**<br> |**System**||**Thru-beam1**|**Reflex2**|**Polarised reflex2**|**Diffuse3**| |---|---|---|---|---|---| |**Type of transmission**||Infra-red|Infra-red|Red|Infra-red| |**Nominal sensing distance**(Sn)||**15 m**|**4 m **(with 50 x 50 mm|**1.5 m **(with 50 x 50 mm|**0.10 m**| ||||reflector)|reflector)|| |References of pre-cabled versions|||||| ||Line of sight||||| |3-wire, PNP|along case axis|**XU2-N18PP340**(1)|**XU1-N18PP340**(2)|**XU9-N18PP340**(2)|**XU5-N18PP340**| |Light or dark program-|Line of sight||||| |mable switching|90°to case axis|**XU2-N18PP340W**(1)|**XU1-N18PP340W**(2)|**XU9-N18PP340W**(2)|**XU5-N18PP340W**| ||Line of sight||||| |3-wire, NPN|along case axis|**XU2-N18NP340**(1)|**XU1-N18NP340**(2)|**XU9-N18NP340**(2)|**XU5-N18NP340**| |Light or dark program-|Line of sight||||| |mable switching|90°to case axis|**XU2-N18NP340W**(1)|**XU1-N18NP340W**(2)|**XU9-N18NP340W**(2)|**XU5-N18NP340W**| |Weight (kg)||0.270|0.155|0.155|0.135| ## References of plug-in connector versions ||Line of sight||||| |---|---|---|---|---|---| |3-wire, PNP|along case axis|**XU2-N18PP340D**(1)|**XU1-N18PP340D**(2)|**XU9-N18PP340D**(2)|**XU5-N18PP340D**| |Light or dark program-|Line of sight||||| |mable switching|90°to case axis|**XU2-N18PP340WD**(1)|**XU1-N18PP340WD**(2)|**XU9-N18PP340WD**(2)|**XU5-N18PP340WD**| ||Line of sight||||| |3-wire, NPN|along case axis|**XU2-N18NP340D**(1)|**XU1-N18NP340D**(2)|**XU9-N18NP340D**(2)|**XU5-N18NP340D**| |Light or dark program-|Line of sight||||| |mable switching|90°to case axis|**XU2-N18NP340WD**(1)|**XU1-N18NP340WD**(2)|**XU9-N18NP340WD**(2)|**XU5-N18NP340WD**| |Weight (kg)||0.130|0.085|0.085|0.065| Complementary characteristics not shown under general characteristics (page 1/17) |**Connection**<br>Pre-cabled|Diameter 5 mm cable, length 2 m (3), wire c.s.a. : 4 x 0.34 mm2| |---|---| |Connector|M12 male connector, 4-pin (suitable female connectors (pre-wired and screw terminal) types 3, 4 & 5, see page 1/160)| |**Materials**|Case : nickel plated brass, lens : PMMA, cable : PVC| |**Rated supply voltage**|**a 12…24 V with protection against reverse polarity**| |**Voltage limits**|a10…30 V (including ripple)| |**Switching capacity**(sealed)|≤ **100 mA with overload and short-circuit protection**| |**Voltage drop, closed state**|≤1.5 V| |**Current consumption, no-load**|≤30 mA (reflex and diffuse),≤50 mA (thru-beam)| |**Maximum switching frequency**|500 Hz| |**Delays**|First-up :≤15 ms ; response :≤1 ms ; recovery :≤1 ms| (1) Reference for both transmitter and receiver for thru-beam system sensors. (2) 50 x 50 mm reflector included with reflex and polarised reflex system sensors. (3) Sensors available with 5 m cable. To order, add the suffix **L5** to the reference selected from above. Example : sensor **XU1-N18PP340** with 5 m cable becomes **XU1-N18PP340L5** . > 1/20 Te **1** ## Photo-electric sensors ## Osiris[®] optimum sensors Metal case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output Accessories : pages 1/154 to 1/159 ## Curves, dimensions, schemes ## **Detection curves** **==> picture [358 x 261] intentionally omitted <==** **----- Start of picture text -----**<br> Thru-beam system Reflex system Polarised reflex system<br>Ø of beam Ø of beam Ø of beam<br>cm cm cm<br>10 6<br>15 4<br>T Ø 12 mm R T/R 4 T/R 2<br>10 15 m -4 2 4 m -2 0,2 1,5 2 m<br>-15 -10 -4<br>-6<br>Sn ≤ 15 m Sn ≤ 4 m Sn ≤ 1,5 m<br>With reflector XUZ-C50 With reflector XUZ-C50<br>Excess gain curves (ambient temperature : + 25 °C)<br>Thru-beam system Reflex system Polarised reflex system<br>gain gain gain<br>100 100 10<br>80<br>50<br>20<br>30<br>20 10<br>10 1<br>8<br>5 1<br>3<br>2<br>1 0,1 0,1<br>1 2 3 4 5 6 8 10 15 20 30 50 0,1 0,2 0,5 1 4 5 10 0,1 0,5 1<br>D (m) D (m)<br>With reflector XUZ-C50 With reflector XUZ-C50<br>**----- End of picture text -----**<br> **==> picture [126 x 129] intentionally omitted <==** **----- Start of picture text -----**<br> Polarised reflex system<br>gain<br>10<br>1<br>0,1<br>0,1 0,5 1 1,5 3 5<br>D (m)<br>**----- End of picture text -----**<br> **==> picture [124 x 270] intentionally omitted <==** **----- Start of picture text -----**<br> Diffuse system<br>Ø of beam<br>cm<br>T/R 1,4<br>1<br>2 1<br>10 cm<br>-1<br>-1,4<br>Sn ≤ 0,10 m<br>Object 10 x 10 cm<br>1 White 90%<br>2 Grey 18%<br>Diffuse system<br>gain<br>50<br>30<br>20<br>15<br>10<br>7<br>5<br>3<br>2<br>1<br>0,1 0,2 0,5 1 2 5 10 20 60<br>D (cm)<br>Object 10 x 10 cm<br>White 90%<br>**----- End of picture text -----**<br> **==> picture [454 x 213] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions<br>XU i -N18 ii 340 XU i -N18 ii 340W<br>4 4<br>M18x1 (1) M18x1 (1)<br>Ø5 Ø5<br>50 24 50 24<br>62 (2) 78<br>XU i -N18 ii 340D XU i -N18 ii 340WD<br>4 4<br>M18x1 (1) M18x1 (1)<br>50 24 50 24<br>62 62<br>72 88<br>**----- End of picture text -----**<br> (1) LED (2) 64 for XU9-N18 ii 340 ## **Cable connections** - (–) BU (Blue) - (+) BN (Brown) - (OUT) BK (Black) - (Prog.) OG (Orange) - (Test) VI (Violet) for thru-beam transmitter only **Beam break test** (for thru-beam transmitter only) Beam made BN/1 + Beam broken BN/1 + VI/2 VI/2 BU/3 – BU/3 – Fixing nut tightening torque : < 15 N.m Connector tightening torque : 2 N.m **==> picture [253 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> Connector schemes (Sensor connector pin view )<br>Transmitter Thru-beam receiver, reflex and diffuse<br>1 (+) 1 (+)<br>2 4 2 4<br>Test Program- Output<br>3 (–) ming 3 (–)<br>**----- End of picture text -----**<br> Te 1/21 Photo-electric sensors Osiris[®] universal sensors, design 18 Plastic or metal case, cylindrical, M18 x 1 threaded Solid state output ## Presentation **==> picture [571 x 656] intentionally omitted <==** **----- Start of picture text -----**<br> Plastic case d.c. supply Pre-cabled or plug-in connector<br>1 Line of sight along case axis (1)<br>With sensitivity<br>adjustment and<br>stability LED<br>è<br>Page 1/24<br>Metal case d.c. supply Pre-cabled or plug-in connectorLine of sight along case axis or 90 ° to case axis<br>With sensitivity<br>adjustment and<br>stability LED<br>è<br>Page 1/26<br>a.c. or d.c.supply Pre-cabled or plug-in connectorLine of sight along case axis or 90 ° to case axis<br>Page 1/28<br>**----- End of picture text -----**<br> - (1) Line of sight 90° to case axis possible using mirror adaptor accessory. > 1/22 Te **1** ## Photo-electric sensors Osiris[®] universal sensors, design 18 Plastic or metal case, cylindrical, M18 x 1 threaded Solid state output Common general characteristics, schemes ## Sensing characteristics **Nominal sensing distance Thru-beam system : 15 m Reflex system : 4 m Polarised reflex system : 2 m Diffuse system : 10 and 40 cm** ## Environment |Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes|Osiris®universal sensors, design 18<br>Plastic or metal case, cylindrical, M18 x 1 threaded<br>Solid state output<br>Common general characteristics, schemes| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |ensing characteristics||||||||||||||||||| |**ominal sensing distance**<br>**Th**<br>**Re**<br>**Po**<br>**Di**||**ru-beam system : 15 m**<br>**flex system : 4 m**<br>**larised reflex system : 2 m**<br>**ffuse system : 10 and 40 cm**||||||||||||||||| |<br>nvironment||||||||||||||||||| |**oduct certifications**<br>è||. UL, CSA||||||||||||||||| |**mbient air temperature**<br>O||peration:-25…+ 55 °C. Storage :-40…+ 70°C||||||||||||||||| |<br> <br>**bration resistance**<br>25||<br> gn, amplitude±2 mm (f=10…55 Hz), conforming to IEC 68-2-6||||||||||||||||| |**ock resistance**<br>30||<br> gn, duration 11 ms, conforming to IEC 68-2-27||||||||||||||||| |**gree of protection**<br>**IP**||**67 conforming to IEC 529**||||||||||||||||| |<br> <br>**nction table**<br>Fu<br>utput state (PNP or NPN)<br>Lig<br>dicator (illuminated when<br>nsor output ON)<br>Da||<br>nction|||<br>Thru-beam and reflex systems<br>Diffuse system|||||||||||||| |||ht switching|||<br> <br>No object present<br>Object present<br>No object present<br>Object present<br>in the beam<br>in the beam<br>in the beam<br>in the beam|||||||||||||| |||||||||||||||||||| |||rk switching||||||||||||||||| |chemes||||||||||||||||||| |**iring schemes**(3-wirea)<br>**e-cabled versions**<br>**Lig**<br>ansmitter<br>Thr<br>PN<br>NP<br>**ug-in connector versions**<br>**Lig**<br>ansmitter<br>Thr<br>PN<br>NP<br>BN<br>BU<br>+<br>–<br>VI<br>Test<br>1<br>3<br>2<br>Test||OG<br>BN<br>BK<br>BU<br>+<br>–<br>+<br>–<br>3<br>4<br>1<br>2<br>OG<br>BN<br>BK<br>BU<br>+<br>–<br>+<br>–<br>3<br>4<br>1<br>2<br>**ht switching**(no object present)<br>u-beam receiver & reflex<br>Diffuse<br>P output<br>PNP output<br>N output<br>NPN output<br>**ht switching**(no object present)<br>u-beam receiver & reflex<br>Diffuse<br>P output<br>PNP output<br>N output<br>NPN output||||||||OG|+<br>–<br>+<br>–<br>+<br>–<br>2<br>3<br>4<br>1<br>+<br>–<br>+<br>–<br>2<br>3<br>4<br>1<br>+<br>–<br>BN<br>BU<br>OG<br>BK<br>+<br>–<br>BN<br>BU<br>BK<br>OG<br>+<br>–<br>**Dark switching**(no object present)<br>Thru-beam receiver & reflex<br>Diffuse<br>PNP output<br>PNP output<br>NPN output<br>NPN output<br>**Dark switching**(no object present)<br>Thru-beam receiver & reflex<br>Diffuse<br>PNP output<br>PNP output<br>NPN output<br>NPN output|||||||BN<br>+| |||||||||||BN||||||||| |||||||||||BK||||||||BK<br>–| |||||||||||OG<br>BN<br><br>BU||||||||BU| |||||||||||||||||||| |||||||||||BK<br>BU<br>2||||||||BU<br>OG<br>–<br>+<br>1| |||||||||||1||||||||| ||3|N output||||||||3<br>4<br><br>1<br>2||||||||+<br>4<br>1<br>–<br>2<br>3<br>4| |||||||||||3<br>4||||||||–<br>2<br>3<br>| |||||||||||||||||||| |BN<br>BU<br>**iring schemes**(2-wire<br>**e-cabled versions**<br>ansmitter||BN<br>BU<br>**ht switching**(no object present)<br>u-beam receiver & reflex<br>Diffuse||||||||BN|BN<br>BU<br>**Dark switching**(no object present)<br>Thru-beam receiver & reflex<br>Diffuse|||||||BN| |||||||||||||||||||| ||BU|||||||||BU||||||||BU| |||**ht switching**(no object present)<br>u-beam receiver & reflex<br>Diffuse<br>2<br>3<br>1||||||||2|**Dark switching**(no object present)<br>Thru-beam receiver & reflex<br>Diffuse<br>2<br>3|||||||2| |||||||||||||||||||| |||||3||||||3||||||||3| |||||1||||||||||||||| |||||||||||1|||1|||||| **Attention :** It is essential that a load be connected in series with the sensor. Te 1/23 **1** ## Photo-electric sensors Osiris[®] universal sensors. Plastic case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output With sensitivity adjustment and stability LED Accessories : pages 1/154 to 1/159 ## References, characteristics Design 18 **==> picture [362 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3<br>**----- End of picture text -----**<br> |Osiris®universal sensors. Plastic case, cylindrical, M18 x 1 threaded<br>d.c. supply. Solid state output<br>With sensitivity adjustment and stability LED<br>References, characteristics<br>Accessories :<br>pages 1/154 to 1/159|Osiris®universal sensors. Plastic case, cylindrical, M18 x 1 threaded<br>d.c. supply. Solid state output<br>With sensitivity adjustment and stability LED<br>References, characteristics<br>Accessories :<br>pages 1/154 to 1/159|Osiris®universal sensors. Plastic case, cylindrical, M18 x 1 threaded<br>d.c. supply. Solid state output<br>With sensitivity adjustment and stability LED<br>References, characteristics<br>Accessories :<br>pages 1/154 to 1/159|Osiris®universal sensors. Plastic case, cylindrical, M18 x 1 threaded<br>d.c. supply. Solid state output<br>With sensitivity adjustment and stability LED<br>References, characteristics<br>Accessories :<br>pages 1/154 to 1/159|Osiris®universal sensors. Plastic case, cylindrical, M18 x 1 threaded<br>d.c. supply. Solid state output<br>With sensitivity adjustment and stability LED<br>References, characteristics<br>Accessories :<br>pages 1/154 to 1/159|Osiris®universal sensors. Plastic case, cylindrical, M18 x 1 threaded<br>d.c. supply. Solid state output<br>With sensitivity adjustment and stability LED<br>References, characteristics<br>Accessories :<br>pages 1/154 to 1/159|Osiris®universal sensors. Plastic case, cylindrical, M18 x 1 threaded<br>d.c. supply. Solid state output<br>With sensitivity adjustment and stability LED<br>References, characteristics<br>Accessories :<br>pages 1/154 to 1/159| |---|---|---|---|---|---|---| |**3**<br>**2**<br>**1**<br>Design 18||||||| |**System**||**Thru-beam1**|**Reflex2**|**Polarised reflex2**|**Diffuse3**|| |**Type of transmission**||Infra-red|Infra-red|Red|Red|Infra-red| |<br>**Nominal sensing distance**(Sn)||**15 m**(transmitter +<br>receiver)|**4 m**(with 50 x 50 mm<br>reflector)|**2 m**(with 50 x 50 mm<br>reflector)|<br>**0.10 m**|**0.40 m**| |References of pre-cabled versions||||||| |3-wire, PNP<br>Light or dark<br>programmable<br>switching||**XU2-B18PP340**(1)|**XU1-B18PP340**(2)|**XU9-B18PP340**(2)|**XU8-B18PP340**|**XU5-B18PP340**| |3-wire, NPN<br>Light or dark<br>programmable<br>switching||**XU2-B18NP340**(1)|**XU1-B18NP340**(2)|**XU9-B18NP340**(2)|**XU8-B18NP340**|**XU5-B18NP340**| |Weight (kg)||0.150|0.095|0.095|0.075|0.075| |<br>References of plug-in connector versions||||||| |3-wire, PNP<br>Light or dark<br>programmable<br>switching||**XU2-B18PP340D**(1)|**XU1-B18PP340D**(2)|**XU9-B18PP340D**(2)|<br>**XU8-B18PP340D**|**XU5-B18PP340D**| |3-wire, NPN<br>Light or dark<br>programmable<br>switching||**XU2-B18NP340D**(1)|**XU1-B18NP340D**(2)|**XU9-B18NP340D**(2)|<br>**XU8-B18NP340D**|**XU5-B18NP340D**| |Weight (kg)||0.040|0.040|0.040|0.020|0.020| |<br>Complementary characteristicsnot shown under general characteristics (page 1/23)||||||| |**Connection**|Pre-cabled|Diameter 4 mm cable, length 2 m, wire c.s.a. : 4 x 0.22 mm2(3 x 0.22 mm2for thru-beam transmitter)||||| ||Connector|<br>M12 male connector, 4-pin (suitable female connectors (pre-wired and screw terminal) types 3, 4 & 5, see page 1/160)||||| |**Materials**||Case : PC/ABS ; lens : PMMA ; cable : PVC||||| |**Rated supply voltage**||**a 12…24 V with protection against reverse polarity**||||| |<br>**Voltage limits**||<br>a10…30 V (including ripple)||||| |<br>**Switching capacity**(sealed)||<br>≤ **100 mA with overload and short-circuit protection**||||| |**Voltage drop, closed state**||≤1.5 V||||| |<br>**Current consumption, no-load**||< 35 mA (reflex and diffuse) ;≤50 mA (thru-beam)||||| |<br>**Maximum switching frequency**||<br>500 Hz (thru-beam system : 400 Hz)||||| |**Delays**||First-up :≤30 ms ; response :≤1 ms ; recovery :≤1 ms (thru-beam system : 1.5 ms)||||| |(1) Reference for both transmitter and receiver for thru-beam system sensors.<br>(2) 50 x 50 mm reflector included with reflex system and polarised reflex system sensors.<br>**Note :**These products are equivalent to the discontinued XUB short case sensors. See cross-reference tables, pages 1/162 and 1/163.||||||| (1) Reference for both transmitter and receiver for thru-beam system sensors. (2) 50 x 50 mm reflector included with reflex system and polarised reflex system sensors. **Note :** These products are equivalent to the discontinued XUB short case sensors. See cross-reference tables, pages 1/162 and 1/163. > 1/24 Te **1** ## Photo-electric sensors Osiris[®] universal sensors. Plastic case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output With sensitivity adjustment and stability LED Accessories : pages 1/154 to 1/159 ## Curves, dimensions, schemes **==> picture [526 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> Detection curves<br>Thru-beam system Reflex system Diffuse system (Sn = 10 cm) Diffuse system (Sn = 40 cm)<br>Ø of beam Ø of beam Ø of beam Ø of beam<br>cm cm cm cm<br>6 T/R 1,4 T/R<br>T 15 Ø 12 mm R T/R 42 1 2 1 1 2 1<br>10 15 m -2 0,2 2 3 4 m 10 cm 40 cm<br>-15 -4 -1 -1<br>-6 -1,4<br>Sn ≤ 15 m Sn ≤ 2 m (1) Sn ≤ 0,10 m Sn ≤ 0,40 m<br>Sn ≤ 4 m (2)<br>**----- End of picture text -----**<br> **==> picture [523 x 474] intentionally omitted <==** **----- Start of picture text -----**<br> With reflector XUZ-C50 Object 10 x 10 cm Object 20 x 20 cm<br>(1) Polarised reflex XU9-B18 i P340 1 White 90% 1 White 90%<br>(2) Reflex XU1-B18 i P340 2 Grey 18% 2 Grey 18%<br>Excess gain curves (ambient temperature : + 25 °C)<br>Thru-beam system Reflex system Diffuse system (Sn = 10 cm) Diffuse system (Sn = 40 cm)<br>gain gain gain gain<br>500<br>300 50 50 50<br>2<br>30 30 30<br>100 20 20 20<br>50 15 1 15 15<br>10 10 10<br>7 7 7<br>10 5 5 5<br>5 3 3 3<br>2 2<br>1 1 1 1<br>0,1 0,2 0,5 1 2 3 6 15 0,1 0,25 0,5 1 2 3 4 5 10 0,1 0,5 1 2 5 10 20 60 0,1 0,2 0,5 1 2 5 15 40<br>0,3 0,8 5 10 20 0,7 D (m) 0,2 15 D (cm) 10 20 60<br>D (m) D (cm)<br>With reflector XUZ-C50 Object 10 x 10 cm Object 20 x 20 cm<br>1 Polarised reflex XU9-B18 i P340 White 90% White 90%<br>2 Reflex XU1-B18 i P340<br>Dimensions Cable connections<br>XU i -B18 i P340 XU i -B18 i P340 + XUB-Z0 i (3) (–) BU (Blue)<br>4 M18x1 (2) (1) M18x1 (2) (1) (+) BN (Brown)<br>(OUT) BK (Black)<br>(Prog.) OG (Orange)<br>(Test) VI (Violet) for thru-beam<br>R E transmitter only<br>Ø4<br>34 24 52 24<br>55 80 6<br>XU i -B18 i P340D XU i -B18 i P340D + XUB-Z0 i (3) Connector schemes<br>4 Sensor connector pin view<br>(2) (1) M18x1 (2) (1) Transmitter Thru-beam receiver,<br>reflex and diffuse<br>1 (+) 1 (+)<br>2 4 2 4<br>Test Program- Output<br>34 M18x1 24 52 24 3 (–) ming 3 (–)<br>55 94<br>68<br>(1) LED Fixing nut tightening torque : < 4 N.m<br>(2) Adjustment potentiometer Connector tightening torque : 2 N.m<br>(3) XUB-Z0 i : mirror adaptor for reflecting beam<br>through 90°, see page 1/154<br>Beam break test (for thru-beam transmitter only) Verification of correct operation<br>Beam made Beam broken<br>2<br>1 24<br>2<br>1<br>24<br>**----- End of picture text -----**<br> **==> picture [123 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> Verification of correct operation<br>Thru-beam and reflex systems<br>Signal 1,51<br>level 0,7<br>Red LED<br>Optimum<br>– alignment +<br>LED off LED on<br>**----- End of picture text -----**<br> **==> picture [211 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> BN/1 + BN/1 +<br>VI/2 VI/2<br>BU/3 – BU/3 –<br>**----- End of picture text -----**<br> Te 1/25 **1** ## Photo-electric sensors Osiris[®] universal sensors. Metal case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output With sensitivity adjustment and stability LED Accessories : pages 1/154 to 1/159 ## References, characteristics Design 18 **==> picture [365 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3<br>**----- End of picture text -----**<br> |||||**Diffuse with adjustable**| |---|---|---|---|---| |**System**|**Thru-beam1**|**Polarised reflex2**|**Diffuse3**|**background suppression3**| |**Type of transmission**|Infra-red|Red|Infra-red|Infra-red| |**Nominal sensing distance**(Sn)|**15 m**(transmitter +|**2 m**(with 50 x 50 mm|**0.4 m**|**0.1 m**(0.08…0.12 m)| ||receiver)|reflector)||| References of pre-cabled versions ||Line of sight||||| |---|---|---|---|---|---| |3-wire, PNP|along case axis|**XU2-M18PP340**(1)|**XU9-M18PP340**(2)|**XU5-M18PP340**|**XU8-M18PP340**(4)| |Light or dark program- Line of sight|||||| |mable switching|90°to case axis|**XU2-M18PP340W**(1)|**XU9-M18PP340W**(2)|**XU5-M18PP340W**|**XU8-M18PP340W**(4)| ||Line of sight||||| |3-wire, NPN|along case axis|**XU2-M18NP340**(1)|**XU9-M18NP340**(2)|**XU5-M18NP340**|**XU8-M18NP340**(4)| |Light or dark program- Line of sight|||||| |mable switching|90°to case axis|**XU2-M18NP340W**(1)|**XU9-M18NP340W**(2)|**XU5-M18NP340W**|**XU8-M18NP340W**(4)| |Weight (kg)||0.285|0.170|0.150|0.150| |References of|plug-in connector versions||||| ||Line of sight||||| |3-wire, PNP|along case axis|**XU2-M18PP340D**(1)|**XU9-M18PP340D**(2)|**XU5-M18PP340D**|**XU8-M18PP340D**(4)| |Light or dark program- Line of sight|||||| |mable switching|90°to case axis|**XU2-M18PP340WD**(1)|**XU9-M18PP340WD**(2)|**XU5-M18PP340WD**|**XU8-M18PP340WD**(4)| ||Line of sight||||| |3-wire, NPN|along case axis|**XU2-M18NP340D**(1)|**XU9-M18NP340D**(2)|**XU5-M18NP340D**|**XU8-M18NP340D**(4)| |Light or dark program- Line of sight|||||| |mable switching|90°to case axis|**XU2-M18NP340WD**(1)|**XU9-M18NP340WD**(2)|**XU5-M18NP340WD**|**XU8-M18NP340WD**(4)| |Weight (kg)||0.155|0.095|0.075|0.075| Complementary characteristics not shown under general characteristics (page 1/23) |**Connection**<br>Pre-cabled|Diameter 5 mm cable, length 2 m (3), wire c.s.a. : 4 x 0.34 mm2(3 x 0.34 mm2for thru-beam transmitter)| |---|---| |Connector|M12 male connector, 4-pin (suitable female connectors (pre-wired and screw terminal) types 3, 4 & 5, see page 1/160)| |**Materials**|Case : nickel plated brass, lens : PMMA, cable : PVC| |**Rated supply voltage**|**a 12…24 V with protection against reverse polarity**| |**Voltage limits**|a10…30 V (including ripple)| |**Switching capacity**(sealed)|≤ **100 mA with overload and short-circuit protection**| |**Voltage drop, closed state**|≤1.5 V| |**Current consumption, no-load**|≤35 mA (reflex and diffuse),≤50 mA (thru-beam)| |**Maximum switching frequency**|500 Hz| |**Delays**|First-up :≤15 ms ; response :≤1 ms ; recovery :≤1 ms| (1) Reference for both transmitter and receiver for thru-beam system sensors. (2) 50 x 50 mm reflector included with polarised reflex system sensors. (3) Sensors available with 5 m cable, To order, add the suffix **L5** to the reference selected from above. Example : sensor **XU9-M18PP340** with 5 m cable becomes **XU9-M18PP340L5** . (4) These sensors do not incorporate stability LED. > 1/26 Te **1** ## Photo-electric sensors Osiris[®] universal sensors. Metal case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output With sensitivity adjustment and stability LED Accessories : pages 1/154 to 1/159 ## Curves, dimensions, schemes **==> picture [523 x 667] intentionally omitted <==** **----- Start of picture text -----**<br> Detection curves<br>Thru-beam system Polarised reflex system Diffuse system (Sn = 40 cm) Diffuse system with background<br>suppression (Sn = 10 cm)<br>Ø of beam Ø of beam Ø of beam Ø of beam<br>cm cm cm cm<br>6 T/R T/R<br>T 15 Ø 12 mm R T/R 42 1 1 1 1<br>2<br>10 15 m -2 0,2 1 2 m 40 cm 12 cm<br>-15 -4 -1 -1<br>-6<br>Sn ≤ 15 m Sn ≤ 2 m Sn ≤ 0,40 m Sn ≤ 0,10 m<br>With reflector XUZ-C50 Object 10 x 10 cm Object 10 x 10 cm<br>1 White 90% 1 White 90%<br>2 Grey 18% 2 Grey 18%<br>Excess gain curves (ambient temperature : + 25 °C) Variation of usable sensing<br>Thru-beam system Polarised reflex system Diffuse system (Sn = 40 cm) distance S<br>gain gain gain Diffuse system with adjustable<br>100 10 10 background suppression<br>80 Potentiometer at minimum<br>50<br>B<br>30<br>20 10<br>10 1<br>8<br>5 1<br>3<br>2 A 0,01 0,07 0,1 S (m)<br>1 0,1 0,1 0,08<br>1 2 3 4 5 6 8 10 15 20 30 50 0,1 0,5 1 2 5 10 0,1 1 10 40 100 Diffuse system with adjustable<br>D (m) D (m) D (cm) background suppression<br>With reflector XUZ-C50 Object 10 x 10 cm Potentiometer at maximum<br>White 90%<br>Dimensions B<br>XU i -M18 i P340 XU i -M18 i P340W<br>4 4<br>M18x1 (2) (1) M18x1 (2) (1)<br>Ø5 Ø4 A 0,01 0,110,12 0,15 S (m)<br>55 24 55 24<br>82 97<br>A-B : Object reflection coefficient<br>Black 6 %<br>XU i -M18 i P340D XU i -M18 i P340WD Grey 18 %<br>4 4 White 90 %<br>M18x1 (2) (1) M18x1 (2) (1)<br>Sensing range<br>Non sensing zone<br>(Matt surfaces)<br>55 24 55 24<br>82 82<br>95 110<br>(1) LED Fixing nut tightening torque : 15 N.m<br>(2) Potentiometer Connector tightening torque : 2 N.m<br>Cable connections Connector schemes Verification of correct operation<br>Sensor connector pin view Thru-beam and reflex systems<br>- (–) BU (Blue) Transmitter Thru-beam receiver, reflex and diffuse<br>--- (+)(OUT)(Prog.) OGBNBK (Orange)(Brown)(Black) 2 1 (+) 4 2 1 (+) 4 Signallevel 1,50,71<br>- (Test) VI (Violet) for thru-beam Test Program- Output<br>transmitter only 3 (–) ming 3 (–) Red LED<br>Optimum<br>– alignment +<br>Beam break test (for thru-beam transmitter only)<br>Beam made Beam broken LED off LED on<br>BN/1 + BN/1 +<br>VI/2 VI/2<br>BU/3 – BU/3 –<br>**----- End of picture text -----**<br> Te 1/27 **1** ## Photo-electric sensors Osiris[®] universal sensors. Metal case, cylindrical, M18 x 1 threaded a.c. or d.c. supply. Solid state output With sensitivity adjustment Accessories : pages 1/154 to 1/159 ## References, characteristics ## Design 18 **==> picture [366 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> 1 2 3<br>**----- End of picture text -----**<br> |||||**Diffuse with adjustable**| |---|---|---|---|---| |**System**|**Thru-beam1**|**Polarised reflex2**|**Diffuse3**|**background suppression3**| |**Type of transmission**|Infra-red|Red|Infra-red|Infra-red| |**Nominal sensing distance**(Sn)|**15 m**(transmitter +|**2 m**(with 50 x 50 mm|**0.4 m**|**0.1 m**(0.08…0.12 m)| ||receiver)|reflector)||| References of pre-cabled versions ||Line of sight||||| |---|---|---|---|---|---| |2-wire|along case axis|**XU2-M18MB230**(1)|**XU9-M18MB230**(2)|**XU5-M18MA230**|**XU8-M18MA230**| |Light switching|Line of sight||||| ||90°to case axis|**XU2-M18MB230W**(1)|**XU9-M18MB230W**(2)|**XU5-M18MA230W**|**XU8-M18MA230W**| ||Line of sight||||| |2-wire|along case axis|**XU2-M18MA230**(1)|**XU9-M18MA230**(2)|**XU5-M18MB230**|**XU8-M18MB230**| |Dark switching|Line of sight||||| ||90°to case axis|**XU2-M18MA230W**(1)|**XU9-M18MA230W**(2)|**XU5-M18MB230W**|**XU8-M18MB230W**| |Weight (kg)||0.285|0.170|0.150|0.150| |References of plug-in connector versions|||||| ||Line of sight||||| |2-wire|along case axis|**XU2-M18MB230K**(1)|**XU9-M18MB230K**(2)|**XU5-M18MA230K**|**XU8-M18MA230K**| |Light switching|Line of sight||||| ||90°to case axis|**XU2-M18MB230WK**(1)|**XU9-M18MB230WK**(2)|**XU5-M18MA230WK**|**XU8-M18MA230WK**| ||Line of sight||||| |2-wire|along case axis|**XU2-M18MA230K**(1)|**XU9-M18MA230K**(2)|**XU5-M18MB230K**|**XU8-M18MB230K**| |Dark switching|Line of sight||||| ||90°to case axis|**XU2-M18MA230WK**(1)|**XU9-M18MA230WK**(2)|**XU5-M18MB230WK**|**XU8-M18MB230WK**| |Weight (kg)||0.155|0.095|0.075|0.075| Complementary characteristics not shown under general characteristics (page 1/23) |**Connection**<br>Pre-cabled|Diameter 5 mm cable, length 2 m (3), wire c.s.a. : 2 x 0.5 mm2| |---|---| |Connector|Ø 12 male, 3-pin (suitable female connectors (pre-wired and screw terminal) types 6 & 7, see pages 1/160 and 1/161 )| |**Materials**|Case : nickel plated brass, lens : PMMA, cable : PVC| |**Rated supply voltage**|a **or** c**24…240 V**| |**Voltage limits**|aorc20…264 V (including ripple ona)| |**Switching capacity**(sealed)|**10…200 mA**(4)| |**Voltage drop, closed state**|< 6 V| |**Residual current, open state**|< 1.5 mA| |**Maximum switching frequency**|25 Hz| |**Delays**|First-up :≤300 ms ; response :≤20 ms ; recovery :≤20 ms| (1) Reference for both transmitter and receiver for thru-beam system sensors. (2) 50 x 50 mm reflector included with polarised reflex system sensors. (3) Sensors available with 5 m cable. To order, add the suffix **L5** to the reference selected from above. Example : sensor **XU9-M18MA230** with 5 m cable becomes **XU9-M18MA230L5** . (4) These sensors do not incorporate overload or short-circuit protection and therefore, it is recommended that a 0.8 A “quick-blow” fuse be connected in series with the load. See page 1/156. > 1/28 Te **1** ## Photo-electric sensors Osiris[®] universal sensors. Metal case, cylindrical, M18 x 1 threaded a.c. or d.c. supply. Solid state output With sensitivity adjustment ## Curves, dimensions, schemes Accessories : pages 1/154 to 1/159 **==> picture [523 x 559] intentionally omitted <==** **----- Start of picture text -----**<br> Detection curves<br>Thru-beam system Polarised reflex system Diffuse system (Sn = 40 cm) Diffuse system with background<br>suppression (Sn = 10 cm)<br>Ø of beam Ø of beam Ø of beam Ø of beam<br>cm cm cm cm<br>6 T/R T/R<br>T 15 Ø 12 mm R T/R 42 1 1 1 1<br>2<br>10 15 m -2 0,2 1 2 m 40 cm 12 cm<br>-15 -4 -1<br>-6 -1<br>Sn ≤ 15 m Sn ≤ 2 m Sn ≤ 0,10 m<br>Sn ≤ 0,40 m<br>With reflector XUZ-C50 Object 10 x 10 cm Object 10 x 10 cm<br>1 White 90% 1 White 90%<br>2 Grey 18% 2 Grey 18%<br>Excess gain curves (ambient temperature : + 25 °C)<br>Thru-beam system Polarised reflex system Diffuse system (Sn = 40 cm) Variation of usable sensing<br>distance S<br>gain gain gain Diffuse system with adjustable<br>100 10 10 background suppression<br>80 Potentiometer at minimum<br>50 B<br>30<br>20 10<br>10 1<br>8<br>5 1<br>3<br>A<br>2 0,01 0,07 0,1 S (m)<br>0,08<br>1 1 2 3 4 5 6 8 10 15 20 30D (m)50 0,10,1 0,5 1 2 5 D (m)10 0,10,1 1 10 40D (cm)100 Diffuse system with adjustablebackground suppression<br>Potentiometer at maximum<br>B<br>With reflector XUZ-C50 Object 10 x 10 cm<br>White 90%<br>Dimensions<br>XU i -M18M i 230 XU i -M18M i 230W<br>4 4<br>M18x1 (2) (1) M18x1 (2) (1)<br>A 0,01 0,11 0,15 S (m)<br>0,12<br>Ø5 Ø4 A-B : Object reflection coefficient<br>55 24 55 24 Black 6 %<br>Grey 18 %<br>82 97 White 90 %<br>Sensing range<br>Non sensing zone<br>XU i -M18M i 230K XU i -M18M i 230WK (Matt surfaces)<br>4 4<br>M18x1 (2) (1) M18x1 (2) (1)<br>55 24 55 24<br>83 83<br>95 110<br>(1) LED Fixing nut tightening torque : 15 N.m<br>(2) Potentiometer Connector tightening torque : 2 N.m<br>Cable connections Connector scheme<br>**----- End of picture text -----**<br> Fixing nut tightening torque : 15 N.m Connector tightening torque : 2 N.m **Connector scheme** Sensor connector pin view Thru-beam, reflex and diffuse - ( z ) BU (Blue) - - ( z ) BN (Brown) **==> picture [44 x 28] intentionally omitted <==** **----- Start of picture text -----**<br> 2 3<br>**----- End of picture text -----**<br> **Attention** : It is essential that a load be connected in series with the sensor. Te 1/29
Updated at June 8, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →