XTR-240-48LA
AC/DC DIN Rail Power Supply (PSU), Lever-Actuated, ITE, Industrial & Laboratory Equipment, 1 Output
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (25-Jun-2025)
- Product Range: XTR-240 Series
- No. of Outputs: 1 Output
- Output Power Max: 240W
- Current, Output 4: -
- Input Voltage VAC: 320V AC to 600V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Laboratory Equipment
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 85.61 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [445 x 178] intentionally omitted <==** **----- Start of picture text -----**<br> 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power XTR - 240 series<br>Tee<br>User’s Manual<br>ae<br>Click Me<br>3 ae = ae<br>I , B xtp-240-24LA |<br>(XTR-240-xx) (XTR-240-xxLA) (XTR-240-xxPI)<br> <br> <br> <br>**----- End of picture text -----**<br> **==> picture [326 x 178] intentionally omitted <==** **----- Start of picture text -----**<br> Characteristics VerifiedVoltage Sag Immunity SEMI F47 BauarSicherheitbeegelodwacmat geprufto ges g<br>DNV www.ID 2000000000tuv.com<br>B® |= DNV.COM/AF B@«4 LISTED @.LISTED BS EN/EN62368-1BS EN/EN61558-1 CB IEC62368-1IEC61558-1 & (Note.8)<br>1 UL61010 BS EN/EN61010-1 IEC61010-1<br>IS13252<br>THOMAS SAMUEL THOMAS SAMUEL<br>By request KC62368-1 Ie CNS15598-1 S @HICE GB4943 . 1 TPTC004 &<br>( Note.9 ) (By request)<br>■ <br>‧<br><br>‧<br><br>‧<br>‧<br>EAPPROVED RPOD<br>V E R I F I E D verify.UV437575L.com<br>TYP UCT<br>**----- End of picture text -----**<br> ## ■ **** - ‧ - ‧ - ‧ - ‧ - ‧ - ‧ ## ■ **** ‧ ‧ https://www.meanwell.com/serviceGTIN.aspx ‧ ‧ ‧℃℃ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ‧ ■ **** ℃℃ ■ ** ** ~~Pee~~ ee [L ~~E~~ ee _File Name:XTR-240-SPEC 2026-04-10_ ## 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power **XTR - 240 series** |**SPECIFICATION**|**SPECIFICATION**|**=Blank, LA, PI**<br>**=Blank, P**<br>**XTR-240 -36**<br>**XTR-240 -12**<br>**XTR-240 -48**<br>**XTR-240 -24**|**=Blank, LA, PI**<br>**=Blank, P**<br>**XTR-240 -36**<br>**XTR-240 -12**<br>**XTR-240 -48**<br>**XTR-240 -24**|**=Blank, LA, PI**<br>**=Blank, P**<br>**XTR-240 -36**<br>**XTR-240 -12**<br>**XTR-240 -48**<br>**XTR-240 -24**|**=Blank, LA, PI**<br>**=Blank, P**<br>**XTR-240 -36**<br>**XTR-240 -12**<br>**XTR-240 -48**<br>**XTR-240 -24**| |---|---|---|---|---|---| |**OUTPUT**|||||| |**DC VOLTAGE**||12V|24V|36V|48V| |**RATED CURRENT**||15A|10A|6.66A|5A| |**CURRENT RANGE**||0 ~ 15A|0 ~ 10A|0 ~ 6.66A|0 ~ 5A| |**RATED POWER**||180W|240W|239.8W|240W| |**RIPPLE & NOISE (max.)**<br>**Note.2**<br>**CURRENT(5 sec.)**<br>**POWER(5 sec.)**<br>**PEAK**|**CURRENT(5 sec.)**|22.5A|15A|10A|7.5A| ||**POWER(5 sec.)**|270W|360W|360W|360W| |||100mVp-p|100mVp-p|120mVp-p|120mVp-p| |**VOLTAGE ADJ. RANGE**||12 ~ 15V|24 ~ 29V|36 ~ 42V|48 ~ 55V| |**VOLTAGE TOLERANCE**<br>**Note.3**||±1.0%|±1.0%|±1.0%|±1.0%| |**LINE REGULATION**||±0.5%|±0.5%|±0.5%|±0.5%| |**LOAD REGULATION**||±1.0%|±1.0%|±1.0%|±1.0%| |**SETUP, RISE TIME**||2000ms, 60ms/400Vac 1500ms, 60ms/500Vac at full load|||| |**HOLD UP TIME (Typ.)**||20ms / 400V<br>40ms / 500V<br>at full load<br>ac<br>ac|||| |**INPUT**|||||| |**VOLTAGE RANGE**<br>**Note.4**||Three-Phase 320 ~<br>450 ~ 800Vdc (Dual phase operation possible<br>,L3 is DC+ )<br>600Vac<br>in connecting L1,L3,FG or L2,L3,FG|||| |**N**<br>**(Typ.)**<br>**O LOAD POWER** **CONSUMPTION**||2.5W/400Vac|2.5W/400Vac|2.5W/400Vac|2.5W/400Vac| |**FREQUENCY RANGE**||47 ~ 63Hz|||| |**POWER FACTOR (Typ.)**||PF≧0.53/400Vac PF≧0.52/500Vac at full load|||| |**EFFICIENCY (Typ.)**||88.7%|92.5%|92.5%|93.5%| |**AC CURRENT (Typ.)**||0.69A/400Vac 0.6A/500Vac|||| |**INRUSH CURRENT (Typ.)**||COLD START10A/400Vac|||| |**LEAKAGE CURRENT**||<2mA / 530Vac|||| |**PROTECTION**|||||| |**OVERLOAD**<br>**OVER VOLTAGE**||105%~150% rated output power for more than 5 sec then<br>at rate current when Vo=30%~100%<br>constant current limiting without shutdown|||| |||15 ~ 18V|30 ~ 36V|45 ~ 54V|56 ~ 65V| |||Hiccup mode , recovers automatically after fault condition is removed|||| |**OVER TEMPERATURE**||Shut down o/p voltage<br>, recovers automatically after temperature goes down<br>or hiccup mode|||| |**FUNCTION**|||||| |**PARALLEL(Optional)**||Up to<br>, please refer to Function Manual for more details<br>960W (3+1)|||| |**DC OK**<br>**TACT**<br>**RELAY CON**||Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5A resistive load|||| |**ENVIRONMENT**|||||| |**WORKING TEMP.**<br>**Note.5**||-40 ~ +85℃(Refer to "Derating Curve")|||| |**WORKING HUMIDITY**||20 ~ 95% RH non-condensing|||| |**STORAGE TEMP., HUMIDITY**||-40 ~ +85℃, 10 ~ 95% RH non-condensing|||| |**TEMP. COEFFICIENT**||±0.03%/℃(0 ~ 60℃)|||| |**VIBRATION**||Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6|||| _File Name:XTR-240-SPEC 2026-04-10_ > 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power **XTR - 240 series** |**SPECIFICATION**|**=Blank, LA, PI**<br>**=Blank, P**<br>**XTR-240 -36**<br>**XTR-240 -12**<br>**XTR-240 -48**<br>**XTR-240 -24**|**=Blank, LA, PI**<br>**=Blank, P**<br>**XTR-240 -36**<br>**XTR-240 -12**<br>**XTR-240 -48**<br>**XTR-240 -24**|**=Blank, LA, PI**<br>**=Blank, P**<br>**XTR-240 -36**<br>**XTR-240 -12**<br>**XTR-240 -48**<br>**XTR-240 -24**|**=Blank, LA, PI**<br>**=Blank, P**<br>**XTR-240 -36**<br>**XTR-240 -12**<br>**XTR-240 -48**<br>**XTR-240 -24**| |---|---|---|---|---| |**SAFETY & EMC**<br>**Note.7&8&9**||||| |**SAFETY STANDARDS**|CB<br>TUV<br>UL<br>CCC<br>BSMI<br>EAC<br>Marine DNV<br>SEMI F47<br>KC/BIS<br>IEC 62368-1, IEC 61558-1/2-16, IEC 61010-1/-2-201<br>BS EN/EN 62368-1, BS EN /EN 61558-1/-2-16, BS EN/EN 61010-1/-2-201<br>UL121201/CSA C22.2 NO.213.17 Class I, Div. 2 Group A, B, C, D Hazardous Locations T4; UL/CUL 61010-1/-2-201<br>GB4943.1<br>CNS15598-1<br>TPTC004<br>approved<br>KC 62368-1 and BIS IS 13252 (Part 1) certified, No stock,contact sales by request|||| |**OVER VOLTAGE CATEGORY**<br>**Note.6**|IEC/EN 61558-1/-2-16 (<br>altitude up to 2000m )<br>OVCⅢ,<br>IEC/EN/UL 61010-1/-2-201 (OVC<br>, altitude up to<br>)<br>Ⅱ<br>000m<br>5<br>IEC/EN 62368-1 (OVC<br>, altitude up to<br>)<br>Ⅱ<br>5000m|||| |**SAFETY EXTRA-LOW VOLTAGE(SELV)**|IEC/EN 61558-2-16 (<br>SELV)<br>IEC/EN 62368-1 (<br>)<br>SELV/ ES1 12V/24V/36V|||| |**WITHSTAND VOLTAGE**|I/P-O/P:<br>I/P-FG:2.5KVac O/P-FG:0.5KVac O/P-DC OK:0.5KVac<br>4.87KVac|||| |**EMC EMISSION**<br>**EMC IMMUNITY**<br>**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH|||| ||**Parameter**|**Standard**||**Test Level / Note**| ||Conducted|BS EN/<br>KS C 9832<br>EN55032(CISPR32) / BS EN/EN61204-3 / CNS15936 /||Class B| ||Radiated|BS EN/<br>KS C 9832<br>EN55032(CISPR32) / BS EN/EN61204-3 / CNS15936 /||Class B| ||Harmonic Current|BS EN/EN61000-3-2||Class A| ||Voltage Flicker|BS EN/EN61000-3-3||-----| ||BS EN/<br>,<br>EN55035 , BS EN/EN61204-3 , BS EN/EN61000-6-2:2005 , BS EN/EN IEC61000-6-2:2019<br>KS C 9835,SEMI F47 tested at 200Vac|||| ||**Parameter**|**Standard**|**Test Level / Note**|| ||ESD|BS EN/EN61000-4-2|Level 4,<br>air ; Level 4,<br>contact<br>15KV<br>8KV|| ||Radiated Field|BS EN/EN61000-4-3|Level 3, 10V/m ; criteria A|| ||EFT / Burst|BS EN/EN61000-4-4|Level 4, 4KV ; criteria A|| ||Surge|BS EN/EN61000-4-5|Level 4, 2KV / Line-Line, Level 4, 4KV/ Line-Earth|| ||Conducted|BS EN/EN61000-4-6|Level 3, 10V/m ; criteria A|| ||Magnetic Field|BS EN/EN61000-4-8|Level 4, 30A/m ; criteria A|| ||Voltage Dips and Interruptions|BS EN/EN61000-4-11|>95% dip 0.5 periods, 30% dip 25<br>periods>95% interruptions 250 periods|| |**OTHERS**||||| |**MTBF**|1432.3K hrs min. Telcordia SR-332(Bellcore) ; 191.5K hrs min. MIL-HDBK-217F (25℃)|||| |**DIMENSION**|**48*125.2*125mm (W*H*D)**|||| |**PACKING**|990g ; 12pcs/12.9Kg/1.16CUFT|||| |**NOTE**||||| |1. All parameters NOT specially mentioned are measured at 400Vac input, rated load and 25℃of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>& 47<br>parallel capacitor.<br>μF<br>μF<br>3. Tolerance : includes set up tolerance, line regulation and load regulation.<br>4. Dual phase operation is allowed under certain derating to output load. Please refer to derating curves for details.<br>5. Installation clearances : 40mm on top, 20mm on the bottom,<br>when loaded permanently with full power.<br>5mm on the left and right side are recommended<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the<br>EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>8.The Regulatory Compliance Mark (RCM) is applied on a voluntary basis. The equipment meets the relevant IEC or AS/NZS standards, or AS/NZS 3820 where applicable.<br>The use of the RCM mark complies with AS/NZS 4417.1.<br>9. Some factory or model may not have the BIS logo, please contact your MEAN WELL sales for more information.<br>※Product Liability Disclaimer:For detailed information, please refer to<br>https://www.meanwell.com/serviceDisclaimer.aspx||||| 1. All parameters NOT specially mentioned are measured at 400Vac input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Dual phase operation is allowed under certain derating to output load. Please refer to derating curves for details. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft). 7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the - EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” - (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) 8. The Regulatory Compliance Mark (RCM) is applied on a voluntary basis. The equipment meets the relevant IEC or AS/NZS standards, or AS/NZS 3820 where applicable. The use of the RCM mark complies with AS/NZS 4417.1. 9. Some factory or model may not have the BIS logo, please contact your MEAN WELL sales for more information. ※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:XTR-240-SPEC 2026-04-10_ ## 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power **XTR - 240 series** ## **Block Diagram** **==> picture [490 x 388] intentionally omitted <==** **----- Start of picture text -----**<br> PWM fosc : 60KHz<br>DC OK<br>ORING FET<br>EMI FILTER PASSIVE POWER RECTIFIERS By request +Vo<br>Input & PFC SWITCHING & -Vo<br>RECTIFIERS FILTER<br>O.C.P.<br>O.L.P.<br>DETECTION<br>FG<br>PWM CIRCUIT<br>CONTROL CONTROL<br>O.V.P.<br>O.T.P.<br>PARALLEL P+<br>By request P-<br>Derating Curve<br>Suitable for 320Vac-380Vac System Suitable for 380Vac-600Vac System<br>Please refer to Function Manual of peak power Please refer to Function Manual of peak power<br>150 150<br>Three phase operation Three phase operation<br>100 100<br>80 Dual phase operation 80 Dual phase operation<br>50 50<br>30 30<br>-40 -30 0 10 20 30 40 50 60 70 85 (VERTICAL) -40 -30 0 10 20 30 40 50 60 70 85 (VERTICAL)<br>AMBIENT TEMPERATURE ( ℃ ) AMBIENT TEMPERATURE ( ℃ )<br>Note : Dual phase operating temperature is between -30℃~+85℃.<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> ## **Output derating VS input voltage** **==> picture [402 x 180] intentionally omitted <==** **----- Start of picture text -----**<br> Three phase operation<br>100<br>90<br>Dual phase operation<br>80<br>70<br>60<br>50<br>40<br>320 340 380 400 420 440 460 480 500 530 600<br>INPUT VOLTAGE (V) 60Hz<br>Note : When ambient temperature is between -30℃~-10℃ and unit is operated in dual-phase input mode :<br>- At dual-phase input 320~380Vac, power supply can be loaded but might experience hiccup at cold start for 5~10 seconds.<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:XTR-240-SPEC 2026-04-10_ > 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power **XTR - 240 series** ## **Peak Power** **==> picture [395 x 346] intentionally omitted <==** **----- Start of picture text -----**<br> P pk [x] t + P npk x [(T-t)]<br>P =av T ≤ P rated<br>Duty = t x 100% ≤ 35% P av : Average output power�(W)<br>T<br>P pk : Peak output power��(W)<br>t�≤ 5 sec P npk : Non-peak output power(W)<br>P rated : Rated output power(W)<br>P pk t : Peak power width(sec)<br>P av T : Period(sec)<br>P npk<br>t<br>T<br><br>40<br>35<br>30<br>25<br>20<br>15<br>10<br>5<br>198W 216W 234W 252W 270W (12V Model)<br>264W 288W 312W 336W 360W (24~48V Model)<br>(110%) (120%) (130%) (140%) (150%)<br>Duty(%)<br>**----- End of picture text -----**<br> ## **Peak output power (W)** **For example (24V model) :** Vin = 400V Duty_max = 10% P av= P rated = 240W P pk= 360W t�≤ 5 sec 5 sec T ≧ 10% ≧ 50sec P npk�≤ T P avT-t - t P pk P npk�≤ 226W _File Name:XTR-240-SPEC 2026-04-10_ > 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power **XTR - 240 series** ## **Function Manual** |**Pin No.**|**Function**|**Description**| |---|---|---| |1,2|DC OK|Contact close : PSU turns ON/DC_OK ;<br>Contact open : PSU turns OFF/DC_fail;<br>Contact ratings (max.): 30Vdc/1A ,30Vac/0.5A resistive load.| |3|P+ (By request)|Current sharing signal. When units are connected in parallel, the P+ pins of the units should<br>be connected mutually to allow current balance between units.| |4|P- (By request)|Current sharing signal. When units are connected in parallel, the P- pins of the units should<br>be connected mutually to allow current balance between units.<br>P- Signal is internally connected to -Vo.| **==> picture [121 x 246] intentionally omitted <==** **----- Start of picture text -----**<br> +Vo +Vo Vo Vo<br>24V 10A<br>Status<br>Vo Adj.<br>24-29Vdc<br>240W Max.<br>DC OK<br>P+<br>Parallel Use ELI )<br>P-<br>XTR-240-24<br>3Ø 380 - 500Vac<br>© L1 L2 L3<br>**----- End of picture text -----**<br> **==> picture [58 x 53] intentionally omitted <==** **----- Start of picture text -----**<br> DC OK<br>P+<br>(By request)<br>P-<br>**----- End of picture text -----**<br> _File Name:XTR-240-SPEC 2026-04-10_ > 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power **XTR - 240 series** ## **1.Parallel Use (By request)** XTR-240 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : - (1) Parallel operation is available by connecting the units shown as below (P+,P- are connected mutually in parallel). - (2) Difference of output voltages among parallel units should be less than 0.2V. - (3) The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit) x (Number of unit) x 0.9. - (4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. - (5) The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - (6) When in parallel operation, the minimum output load should be greater than 5% of total output load. (Min. load >5% rated current per unit x number of unit) (7) P+ and P- lines should be twisted in pairs **==> picture [421 x 483] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>3 P+<br>+ - 4 P-<br>LOAD<br>+Vo<br>-Vo<br>P+<br>P-<br>1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4<br>+Vo +Vo -Vo -Vo +Vo +Vo -Vo -Vo +Vo +Vo -Vo -Vo +Vo +Vo -Vo -Vo<br>Status Status Status Status<br>DC OK VoAdj. 21 DC OK VoAdj. 21 DC OK VoAdj. 21 DC OK VoAdj. 21<br>Parallel Use(optional) P+P- 34 Parallel Use(optional) P+P- 34 Parallel Use(optional) P+P- 34 Parallel Use(optional) P+P- 34<br>XTR-240 XTR-240 XTR-240 XTR-240<br>PSU1 PSU2 PSU3 PSU4<br>3Ø 380~500Vac 3Ø 380~500Vac 3Ø 380~500Vac 3Ø 380~500Vac<br>L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2 L3<br>※ Please contact MEAN WELL for more details.<br>2.DC OK Relay Contact<br>1<br>Contact Close PSU turns ON / DC OK. DC OK.<br>2<br>Contact Open PSU turns OFF / DC Fail. 3<br>4<br>Contact ratings (max.) 30Vdc/1A ,30Vac/0.5A resistive load.<br>1<br>R<br>U External voltage source (U) and resistor (R)<br>(The max. Sink is 30Vdc/1A ,30Vac/0.5A )<br>2<br>Internal circuit of DC_OK, via relay contact<br>**----- End of picture text -----**<br> ## **2.DC OK Relay Contact** _File Name:XTR-240-SPEC 2026-04-10_ **- XTR 240 series** 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power ## **3.Protection Against Inverse Reverse From The Load (By request)** Prevent PSU damage from Back Electro magnetic Force during deceleration of motor or inductive load. **==> picture [203 x 83] intentionally omitted <==** **----- Start of picture text -----**<br> AC + +<br>Io<br>(By request) DC<br>DC - -<br>(XTR-240) (DC Load)<br>**----- End of picture text -----**<br> |PSU'S ORing FET turn OFF voltage|PSU'S ORing FET turn OFF voltage|PSU'S ORing FET turn OFF voltage| |---|---|---| |PSU'S ORing FET turn OFF voltage||| |MODEL|Max. allowable reverse voltage|| |XTR-240-12|<16V|| |XTR-240-24|<35V|| |XTR-240-36|<50V|| |XTR-240-48|<63V|| |||| _File Name:XTR-240-SPEC 2026-04-10_ > 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power **XTR - 240 series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>(Unit:mm , Tolerance ±1mm) Case No. 303<br>A : Terminal Pin No. Assignment<br>Pin No. Assignment<br>1,2 DC Output +Vo<br>3,4 DC Output -Vo<br>B : Control Pin No. Assignment<br>Pin No. Assignment<br>1,2 DC OK Relay Contact<br>3 P+(Current sharing,By request)<br>4 P-(Current sharing,By request)<br>48<br>125<br>1 2 3 4<br>A<br>+Vo +Vo -Vo -Vo<br>Status<br>Parallel Use(optional)DC OK VoAdj.P+P- 3241 B<br>3Ø 380~500Vac<br>L1 L2 L3<br>C<br>C : Terminal Pin No. Assignment<br>Pin No. Assignment<br>1 FG<br>2 AC/L1 or DC-<br>3 AC/L2 or DC-<br>4 AC/L3 or DC+<br>Recommend Wiring<br>※ Screw Terminal Torque<br>AC Input T.B DC Output T.B Signal connector<br>Solid Wire 6mm max.2 6mm max.2 1.5mm max.2<br>XTR-240-12 12~10 AWG<br>A.W.G 18~10 AWG 24~16 AWG<br>XTR-240-24/36/48 16~10 AWG<br>Wire Stripping Length 10~11mm 10~11mm 8~9mm<br>Screw Terminal Torque 5 Lb-In 5 Lb-In /<br>125.2<br>**----- End of picture text -----**<br> _File Name:XTR-240-SPEC 2026-04-10_ > 240W AC/DC 3 Input Ultra Slim Industrial DIN Rail Power **XTR - 240 series** **==> picture [312 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> ※ Lever-Actuated and Push In<br>AC Input T.B DC Output T.B Signal connector<br>Solid Wire 6mm max.2 6mm max.2 1.5mm max.2<br>XTR-240-12 12~10 AWG<br>A.W.G 18~10 AWG 24~16 AWG<br>XTR-240-24/36/48 16~10 AWG<br>Wire Stripping Length 10~11mm 10~11mm 8~9mm<br>Screw Terminal Torque Not applicable<br>**----- End of picture text -----**<br> ## **Installation Instruction** This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 (For reference only. Not included with unit.) **==> picture [121 x 32] intentionally omitted <==** ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:XTR-240-SPEC 2026-04-10_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →