- Manufacturer: TELEMECANIQUE SENSORS
- Product type: Pressure Transducers
- Port Style: G1/4 (1/4" BSP)
- Sensor Output: Voltage
- Supply Current: 50mA
- Voltage Rating: 24VDC
- Operating Pressure Max: 160bar
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 277.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
Product data sheet Characteristics ## XMLR160M0T75 Pressure sensors XMLR 160bar - G 1/4 - 24VDC - 0..10 V - M12 ## Main |Range of product<br>Product or component type<br>Pressure sensor type<br>Pressure switch type of operation<br>Device short name<br>Pressure sensor size<br>Maximum permissible accidental<br>pressure<br>Destruction pressure<br>Controlled fluid<br>Fluid connection type<br>[Us] rated supply voltage|OsiSense XM<br>Electronic pressure sensors<br>Pressure transmitter<br>Pressure transmitter<br>XMLR<br>160 bar<br>2320 psi<br>480 bar<br>6960 psi<br>48 MPa<br>960 bar<br>13920 psi<br>96 MPa<br>Fresh water (0...80 °C)<br>Air (-20...80 °C)<br>Hydraulic oil (-20...80 °C)<br>Refrigeration fluid (-20...80 °C)<br>G 1/4 (female) conforming to DIN 3852-Y<br>24 V DC SELV, voltage limits: 17...33 V| |---|---| ## Complementary |Current consumption<br>Electrical connection<br>Analogue output function<br>Type of output signal<br>Analogue output function<br>Scale type<br>Materials in contact with fluid<br>Front material<br>Housing material<br>Operating position<br>Protection type|<= 50 mA<br>4 pins M12 male connector<br>0...10 V<br>Analogue<br>0...10 V<br>Fixed differential<br>316L stainless steel<br>Polyester<br>Polyacrylamide<br>316L stainless steel<br>Any position, but disposals can falsified the measurement in case of upside down mounting<br>Overload protection<br>Overvoltage protection<br>Reverse polarity| |---|---| **==> picture [6 x 456] intentionally omitted <==** **----- Start of picture text -----**<br> Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications<br>**----- End of picture text -----**<br> Jun 25, 2019 1 ||Short-circuit protection| |---|---| |Response time on output|<= 10 ms for analog output| |Display type|4 digits 7 segments| |Display response time type|Fast 50 ms| ||Normal 200 ms| ||Slow 600 ms| |Delay first up|<= 300 ms| |Overall accuracy|<= 1 % of the measuring range| |Linearity error on analogue output|<= 0.5 % of the measuring range| |Hysteresis on analogue output|<= 0.2 % of the measuring range| |Measurement accuracy on switching|<= 0.6 % of the measuring range| |output|| |Repeat accuracy|<= 0.2 % of the measuring range| |Drift of the sensitivity|+/- 0.03 % of measuring range/°C| |Drift of the zero point|+/- 0.1 % of measuring range/°C| |Display accuracy|<= 1 % of the measuring range| |Mechanical durability|>= 10000000 cycles| |Depth|42 mm| |Height|88 mm| |Width|41 mm| |Product weight|0.186 kg| |[Uimp] rated impulse withstand voltage|0.5 kV DC| |Electromagnetic compatibility|Electrostatic discharge immunity test - test level 8 kV air, 4 kV contact conforming to EN/IEC| ||61000-4-2| ||Susceptibility to electromagnetic fields - test level 10 V/m (80...2000 MHz) conforming to EN/IEC| ||61000-4-3| ||Electrical fast transient/burst immunity test - test level 2 kV conforming to EN/IEC 61000-4-4| ||Surge immunity test - test level 1 kV conforming to EN/IEC 61000-4-5| ||Immunity to conducted RF disturbances - test level 10 V (0.15...80 MHz) conforming to EN/IEC| ||61000-4-6| ## Environment |Environment|| |---|---| |Marking|CE| |Product certifications|cULus| ||EAC| |Standards|UL 61010-1| ||EN/IEC 61326-2-3| |Ambient air temperature for operation|-20...80 °C| |Ambient air temperature for storage|-40...80 °C| |IP degree of protection|IP65 conforming to EN/IEC 60529| ||IP67 conforming to EN/IEC 60529| |Vibration resistance|20 gn (f = 10...2000 Hz) conforming to EN/IEC 60068-2-6| |Shock resistance|50 gn conforming to EN/IEC 60068-2-27| |Offer Sustainability|| |RoHS (date code: YYWW)|Compliant - since 1351 - Schneider Electric declaration of conformity| ||Schneider Electric declaration of conformity| |REACh|Reference not containing SVHC above the threshold| ||Reference not containing SVHC above the threshold| 2 Product data sheet Dimensions Drawings ## XMLR160M0T75 ## Dimensions **==> picture [131 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> (1) Fluid entry: G 1/4 A female<br>**----- End of picture text -----**<br> 3 Product data sheet Connections and Schema XMLR160M0T75 ## Connections and Schema ## Connector Wiring (1) I Out or V Out (2) Test Input 4 Product data sheet Performance Curves ## XMLR160M0T75 ## Analogue Output Description ## Analogue Output Signal X : Pressure - Y : Analogue output signal (1) An offset of +/-5% of nominal pressure can be compensated (with Cof Configuration menu. Cof: Offset Compensation) (2) The Analogue curve can be adjusted from -25% to +25% of nominal pressure (with AEP Configuration menu. AEP: analogue end point). 5
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →