- Manufacturer: TELEMECANIQUE SENSORS
- Product type: Pressure Transducers
- Port Style: 1/4" - 18 NPT
- Product Range: OsiSense XMLR Series
- Sensor Output: NPN
- Supply Current: 50mA
- Voltage Rating: 24VDC
- Operating Pressure Max: 40bar
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 287.23 € |
| Current stock | 10+ |
| Lead time | 30 days |
Product datasheet Characteristics Pressure sensors XMLR 40bar - 1/4" 18 NPT - 24VDC - 2xNPN - M12 ## XMLR040G2N06 ## Main |Range of product<br>Product or component type<br>Pressure sensor type<br>Pressure switch type of operation<br>Device short name<br>Pressure sensor size<br>Maximum permissible accidental<br>pressure<br>Destruction pressure<br>Controlled fluid<br>Fluid connection type<br>[Us] rated supply voltage|OsiSense XM<br>Electronic pressure sensors<br>Pressure transmitter<br>Pressure switch with 2 switching outputs<br>XMLR<br>40 bar<br>4 MPa<br>580 psi<br>15 MPa<br>2175 psi<br>150 bar<br>2175 psi<br>150 bar<br>15 MPa<br>Fresh water (0...80 °C)<br>Air (-20...80 °C)<br>Hydraulic oil (-20...80 °C)<br>Refrigeration fluid (-20...80 °C)<br>1/4" - 18 NPT (female)<br>24 V DC SELV, voltage limits: 17...33 V| |---|---| |Complementary<br>Current consumption<br>Electrical connection<br>Type of output signal<br>Discrete output type<br>Maximum switching current<br>Voltage drop<br>Adjustable range of switching point on<br>rising pressure|<= 50 mA<br>4 pins M12 male connector<br>Discrete<br>Solid state NPN, 2 NO/NC programmable<br>250 mA<br><= 2 V<br>0.32...4 MPa<br>46.4...580 psi<br>3.2...40 bar| |---|---| Mar 09, 2017 1 |Adjustable range of switching point on|2...38.8 bar| |---|---| |falling pressure|0.2...3.88 MPa| ||29...563 psi| |Minimum differential travel|1.2 bar| ||120 kPa| ||17.4 psi| |Materials in contact with fluid|Ceramic| ||316L stainless steel| ||Fluorocarbon FKM (Viton)| |Front material|Polyester| |Housing material|316L stainless steel| ||Polyacrylamide| |Operating position|Any position, but disposals can falsified the measurement in case of upside down mounting| |Protection type|Short-circuit protection| ||Reverse polarity| ||Overload protection| ||Overvoltage protection| |Response time on output|<= 5 ms for discrete output| |Time delay range|0...50 s in steps of 1 second| |Display type|4 digits 7 segments| |Local signalling|2 LEDs yellow for light ON when switch is actuated| |Display response time type|Fast 50 ms| ||Normal 200 ms| ||Slow 600 ms| |Delay first up|<= 300 ms| |Accuracy|<= 1 % of the measuring range| |Measurement accuracy|<= 0.6 % of the measuring range| |Repeat accuracy|<= 0.2 % of the measuring range| |Drift of the sensitivity|+/- 0.03 % of measuring range/°C| |Drift of the zero point|+/- 0.1 % of measuring range/°C| |Display accuracy|<= 1 % of the measuring range| |Mechanical durability|>= 10000000 cycles| |Depth|42 mm| |Height|100 mm| |Width|41 mm| |Product weight|0.212 kg| |[Uimp] rated impulse withstand voltage|0.5 kV DC| |Electromagnetic compatibility|Electrostatic discharge immunity test - test level 8 kV air, 4 kV contact conforming to EN/IEC| ||61000-4-2| ||Susceptibility to electromagnetic fields - test level 10 V/m (80...2000 MHz) conforming to EN/IEC| ||61000-4-3| ||Electrical fast transient/burst immunity test - test level 2 kV conforming to EN/IEC 61000-4-4| ||Surge immunity test - test level 1 kV conforming to EN/IEC 61000-4-5| ||Immunity to conducted RF disturbances - test level 10 V (0.15...80 MHz) conforming to EN/IEC| ||61000-4-6| ## Environment |Environment|| |---|---| |Marking|CE| |Product certifications|CULus| ||EAC| |Standards|EN/IEC 61326-2-3| ||UL 61010-1| |Ambient air temperature for operation|-20...80 °C| |Ambient air temperature for storage|-40...80 °C| |IP degree of protection|IP65 conforming to EN/IEC 60529| ||IP67 conforming to EN/IEC 60529| |Vibration resistance|20 gn (f = 10...2000 Hz) conforming to EN/IEC 60068-2-6| |Shock resistance|50 gn conforming to EN/IEC 60068-2-27| 2 |Offer Sustainability|| |---|---| |Sustainable offer status|Not Green Premium product| |RoHS (date code: YYWW)|Compliant - since 1351 - Schneider Electric declaration of conformity| ||Schneider Electric declaration of conformity| |REACh|Reference not containing SVHC above the threshold| ||Reference not containing SVHC above the threshold| 3 Product datasheet Dimensions Drawings XMLR040G2N06 ## Dimensions (1) Fluid entry: 1/4”-18NPT female 4 Product datasheet Connections and Schema ## XMLR040G2N06 ## Connections and Schema ## Connector Wiring 5 Product datasheet Performance Curves XMLR040G2N06 ## Switching Output Description. Hysteresis Mode The hysteresis switching mode is typically used for the “pumping and/or emptying applications”. - X : Time - Y : Pressure - (1) Output - NP : Nominal Pressure - SP : Set point (adjustable from 8 % to 100 % NP) - rP : Reset point (adjustable from 5 % to 97 % NP) 6 Product datasheet Performance Curves ## XMLR040G2N06 ## Switching Output Description. Window Mode The window switching mode is typically used for the “pressure regulation applications” X : Time Y : Pressure (1) Output NP : Nominal pressure FH : High switching point (adjustable from 8 % to 100 % NP) FL : Low switching point (adjustable from 5 % to 97 % NP) 7 Product datasheet Performance Curves XMLR040G2N06 ## Switching Output Description. Time Delay The Time Delay is typically used to filter out the fast pressure transients. The output only switches after a time “dS” and “dr” adjustable from 0 to 50 seconds. - X : Time - Y : Pressure - (1) Output - SP : Set point - rP : Reset point dS : Time delay on the set point - dr : Time delay on the reset point 8
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →