XLN-40-H-B
LED Driver, IO Adj W/3in1 Dim, LED Lighting, 40 W, 60 V, 1.4 A, Constant Power, 110 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: XLN-40 Series
- Output Current: 1.4A
- LED Driver Mode: Constant Power
- Output Power Max: 40W
- Input Voltage Max: 305V
- Input Voltage Min: 110V
- Output Voltage Max: 60V
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 17.57 € |
| Current stock | 10+ |
| Lead time | 30 days |
## 40W Multiple-Stage Constant Power/Constant Voltage LED Driver ## **- XLN 40 series** **User’s Manual** nec )))) ~~geesePeas~~ Soc ~~ees~~ , c US " @) CLASS P LED DRIVER (Independent type) E3346874HB3 **Note.11** Type HL 2 IP67 ~~<ai>~~ [ ~~6~~ ] () 7 NW NW EL] [5] sev QR) Ke © Hl CB CE cAef **DC Input:176-280VDC** ■ Features ■ Applications • Constant power mode output with multiple stage • Recessed Light • selectable by NFC setting (H-type) Down Light • • Constant voltage mode output(12V/24V) Panel Light • Plastic housing with class I | and PFC design • Commercial Lighting • Meet UL 8750 Class 2/ Class P power unit • Decorative Lighting • • Flicker free, complying with CE ErP directive LED strip lighting • • Standby power consumption <0.5W DALI digital Lighting • Meet emergency lighting (EL) function application • Fully encapsulated with IP67 • ■ Minimum dimming level 0.1% (DALI-2 DT6) GTIN CODE • Dimming functions: 3 in 1 dimming (Dim-to-off) MW Search: ~~hitos./www.meanwell.com/serviceGTIN.aspx~~ DALI-2 + Push dimming • 5 years warranty ■ Description XLN-40 Series is a 40W with constant power and constant voltage output LED driver . It can operate from 100~305VAC and output current ranging between 600 mA to 1400 mA selectable by NFC setting. Thanks to high efficiency up to 88%, itis able to operate for-25 ℃ ~90 ℃ case temperature under free air **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** 40W Constant Voltage LED Driver ## **SPECIFICATION** |**OUTPUT**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>500ms, 100ms/230VAC, 1000ms, 100ms/115VAC<br>47 ~ 63Hz<br>0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC<br><0.75mA / 277VAC<br>20 ~ 90% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>80℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down and latch off o/p voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**RATED CURRENT**<br>**RATED POWER Note.2**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.5**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>**RATED VOLTAGE**<br>**OVER LOAD**<br>COLD START 10A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>100μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=90℃<br>110 ~ 305VAC 141 ~ 400VDC<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25<br>of ambient temperature.<br>℃<br>2. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>6.<br>strip.<br>Flicker is measured at full load with LED<br>7. To fulfill requirement of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete<br>installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>9. The ambient temperature de-rating of 3.5<br>/1000m with fanless models and 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>10. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75<br>or less.<br>℃<br>11.������������������������������������������������������������������������������������������������������������<br>12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13. For more information, please contact with MEAN WELL sales.<br>Product Liability Disclaimer: For detailed information, please refer to<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>105 ~ 180% rated output power<br>Hiccup mode,recovers automatically after fault condition is removed<br>Protection type:Hiccup mode, recovers automatically after fault condition is removed<br>THD<10%(@load<br>50%/230VAC; @load<br>75%/277VAC), THD<15%(@load<br>50%/115VAC)<br>≧<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Tcase=-25 ~ 90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**XLN-40-12**<br>3.4A<br>120mVp-p<br>12V<br>40.8W<br>±4.0%<br>±0.5%<br>±2%<br>86%<br>13 ~ 16V<br>3935.2 K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>342.9 Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>114*44*32mm (L*W*H)<br>**SAFETY STANDARDS**<br>**XLN-40-24**<br>1.7A<br>24V<br>40.8W<br>26 ~ 32V<br>BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV),<br>EAC TP TC 020<br>BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load>50%); BS EN/EN61000-3-3; GB17625.1,<br>GB/T17743, EAC TP TC 020<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Shut down output voltage,recovers automatically after fault condition is removed<br>**FLICKER Note.6**<br>PstLM<br>1, SVM<br>0.4<br>≤<br>≤<br>**MODEL**<br>88%<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>240mVp-p<br>ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(<br>DC);<br>���������������<br>BS EN/EN62384, GB19510.14, GB19510.1, EAC TP TC 004,<br>(Type HL and Class P)<br>approved<br>UL8750<br>; CSA C22.2 No. 250.13-12<br>;<br>Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13;<br>308g;40pcs / 13.32Kg / 95CUFT<br>0.|**OUTPUT**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>500ms, 100ms/230VAC, 1000ms, 100ms/115VAC<br>47 ~ 63Hz<br>0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC<br><0.75mA / 277VAC<br>20 ~ 90% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>80℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Shut down and latch off o/p voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**RATED CURRENT**<br>**RATED POWER Note.2**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.5**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>**RATED VOLTAGE**<br>**OVER LOAD**<br>COLD START 10A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>100μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=90℃<br>110 ~ 305VAC 141 ~ 400VDC<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25<br>of ambient temperature.<br>℃<br>2. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>6.<br>strip.<br>Flicker is measured at full load with LED<br>7. To fulfill requirement of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete<br>installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>9. The ambient temperature de-rating of 3.5<br>/1000m with fanless models and 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>10. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75<br>or less.<br>℃<br>11.������������������������������������������������������������������������������������������������������������<br>12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13. For more information, please contact with MEAN WELL sales.<br>Product Liability Disclaimer: For detailed information, please refer to<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>105 ~ 180% rated output power<br>Hiccup mode,recovers automatically after fault condition is removed<br>Protection type:Hiccup mode, recovers automatically after fault condition is removed<br>THD<10%(@load<br>50%/230VAC; @load<br>75%/277VAC), THD<15%(@load<br>50%/115VAC)<br>≧<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Tcase=-25 ~ 90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**XLN-40-12**<br>3.4A<br>120mVp-p<br>12V<br>40.8W<br>±4.0%<br>±0.5%<br>±2%<br>86%<br>13 ~ 16V<br>3935.2 K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>342.9 Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>114*44*32mm (L*W*H)<br>**SAFETY STANDARDS**<br>**XLN-40-24**<br>1.7A<br>24V<br>40.8W<br>26 ~ 32V<br>BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV),<br>EAC TP TC 020<br>BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load>50%); BS EN/EN61000-3-3; GB17625.1,<br>GB/T17743, EAC TP TC 020<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Shut down output voltage,recovers automatically after fault condition is removed<br>**FLICKER Note.6**<br>PstLM<br>1, SVM<br>0.4<br>≤<br>≤<br>**MODEL**<br>88%<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>240mVp-p<br>ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(<br>DC);<br>���������������<br>BS EN/EN62384, GB19510.14, GB19510.1, EAC TP TC 004,<br>(Type HL and Class P)<br>approved<br>UL8750<br>; CSA C22.2 No. 250.13-12<br>;<br>Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13;<br>308g;40pcs / 13.32Kg / 95CUFT<br>0.|**XLN-40-12**|**XLN-40-24**| |---|---|---|---| |||12V|24V| ||**RATED CURRENT**|3.4A|1.7A| ||**RATED POWER Note.2**|40.8W|40.8W| ||**RIPPLE & NOISE (max.) Note.3**|120mVp-p|240mVp-p| ||**VOLTAGE TOLERANCE Note.4**|±4.0%|| ||**LINE REGULATION**|±0.5%|| ||**LOAD REGULATION**|±2%|| ||**SETUP, RISE TIME**<br>**Note.5**|500ms, 100ms/230VAC, 1000ms, 100ms/115VAC|| ||**VOLTAGE RANGE**|110 ~ 305VAC 141 ~ 400VDC|| ||**FREQUENCY RANGE**|47 ~ 63Hz|| ||**POWER FACTOR**|PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)|| ||**TOTAL HARMONIC DISTORTION**|THD<10%(@load<br>50%/230VAC; @load<br>75%/277VAC), THD<15%(@load<br>50%/115VAC)<br>≧<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)|| ||**EFFICIENCY (Typ.)**|86%|88%| ||**AC CURRENT**|0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC|| ||**INRUSH CURRENT(Typ.)**|COLD START 10A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>100μ<br>;Per NEMA 410|| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC|| ||**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>**SHORT CIRCUIT**<br>**OVER LOAD**|<0.75mA / 277VAC|| |||105 ~ 180% rated output power|| |||Protection type:Hiccup mode, recovers automatically after fault condition is removed|| |||Hiccup mode,recovers automatically after fault condition is removed|| |||13 ~ 16V|26 ~ 32V| |||Shut down and latch off o/p voltage, re-power on to recover|| |||Shut down output voltage,recovers automatically after fault condition is removed|| ||**WORKING TEMP.**|Tcase=-25 ~ 90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃|| ||**MAX. CASE TEMP.**|Tcase=90℃|| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing|| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +<br>, 10 ~ 95% RH<br>80℃|| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)|| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes|| ||**SAFETY STANDARDS**|ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(<br>DC);<br>���������������<br>BS EN/EN62384, GB19510.14, GB19510.1, EAC TP TC 004,<br>(Type HL and Class P)<br>approved<br>UL8750<br>; CSA C22.2 No. 250.13-12<br>;<br>Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13;|| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC|| ||**ISOLATION RESISTANCE**|I/P-O/P:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|| ||**EMC EMISSION**|BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load>50%); BS EN/EN61000-3-3; GB17625.1,<br>GB/T17743, EAC TP TC 020|| ||**EMC IMMUNITY**|BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV),<br>EAC TP TC 020|| ||**FLICKER Note.6**|PstLM<br>1, SVM<br>0.4<br>≤<br>≤|| ||**MTBF**|3935.2 K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>342.9 Khrs min. MIL-HDBK-217F (25<br>)<br>℃|| ||**DIMENSION**|114*44*32mm (L*W*H)|| ||**PACKING**|308g;40pcs / 13.32Kg / 95CUFT<br>0.|| ||1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25<br>of ambient temperature.<br>℃<br>2. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>6.<br>strip.<br>Flicker is measured at full load with LED<br>7. To fulfill requirement of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete<br>installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>9. The ambient temperature de-rating of 3.5<br>/1000m with fanless models and 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>10. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75<br>or less.<br>℃<br>11.������������������������������������������������������������������������������������������������������������<br>12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13. For more information, please contact with MEAN WELL sales.<br>Product Liability Disclaimer: For detailed information, please refer to<br>※<br>https://www.meanwell.com/serviceDisclaimer.aspx||| _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** ## 40W Multiple-Stage Constant Power LED Driver ## **SPECIFICATION** |**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.) Note.7**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>500ms, 100ms/230VAC, 1000ms, 100ms/115VAC<br>47 ~ 63Hz<br>0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC<br><0.75mA / 277VAC<br>20 ~ 90% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>80℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>DA2 type: Stage 1: De-ratingto 75% loading; Stage 2: De-ratingto 50% loading. Recovers automaticallyafter fault condition is removed.<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**OPEN CIRCUIT**<br>**VOLTAGE Note.2**<br>**DEFAULT CURRENT**<br>**CONSTANT CURRENT**<br>**REGION Note.3**<br>**DIMMING RANGE**<br>**SETUP, RISE TIME**<br>**Note.5,6**<br>**RATED POWER Note.4**<br>**CURRENT RIPPLE**<br>**CURRENT ADJ.RANGE**<br>**(BY NFC)**<br>COLD START 10A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>100μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=90℃<br>110 ~ 305VAC 141 ~ 400VDC<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25<br>of ambient temperature.<br>℃<br>2. Output hiccups under no-load condition.<br>3. Please refer to “DRIVER METHODS OF LED MODULE”.<br>4. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>6. Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller which can support for DALI<br>power on function, otherwise the startup time will be higher than 0.5 second.<br>7. Efficiency is measured at 800mA/50V by NFC.<br>8. Standby power consumption is measured at 230VAC.<br>9.<br>.<br>Flicker is measured at full load with LED modules<br>10. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete<br>installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>11. RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations.<br>12. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75<br>or less.<br>℃<br>13. The ambient temperature de-rating of 3.5<br>/1000m with fanless models and 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>.<br>14 To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.<br>15. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>16. For more information, please contact with MEAN WELL sales.<br>Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>※<br>Hiccup mode,recovers automatically after fault condition is removed<br>THD<10%(@load<br>50%/230VAC; @load<br>75%/277VAC), THD<15%(@load<br>50%/115VAC)<br>≧<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Tcase=-25 ~ 90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**XLN-40-H-**<br>60V<br>0.6~1.4A<br>40W<br>1050mA<br>9~54V<br><4%<br>0~100%<br>88%<br>Blank & B type: De-rating to lowest output level. Recovers automatically after fault condition is removed.<br>114*44*32mm (L*W*H)<br>**SAFETY STANDARDS**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**FLICKER Note.9**<br>PstLM<br>1, SVM<br>0.4<br>≤<br>≤<br>**STANDBY POWER**<br>**CONSUMPTION Note.8**<br>Standby power consumption<0.5W(Dimming off)<br>**DALI STANDARDS**<br>Comply with IEC62386-101,102,207<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>**CURRENT TOLERANCE**<br>±5%<br>3935.2 K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>342.9 Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>311g;60pcs / 13.44Kg / 95CUFT<br>0.<br>BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV),<br>EAC TP TC 020<br>BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load>50%); BS EN/EN61000-3-3; GB17625.1,<br>GB/T17743, EAC TP TC 020<br>ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(<br>DC);<br>���������������<br>BS EN/EN62384, GB19510.14, GB19510.1, EAC TP TC 004,<br>(Type HL and Class P)<br>approved<br>UL8750<br>; CSA C22.2 No. 250.13-12<br>;<br>Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13 ;|**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.) Note.7**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>500ms, 100ms/230VAC, 1000ms, 100ms/115VAC<br>47 ~ 63Hz<br>0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC<br><0.75mA / 277VAC<br>20 ~ 90% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>80℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)<br>10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>DA2 type: Stage 1: De-ratingto 75% loading; Stage 2: De-ratingto 50% loading. Recovers automaticallyafter fault condition is removed.<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC<br>I/P-O/P:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**OPEN CIRCUIT**<br>**VOLTAGE Note.2**<br>**DEFAULT CURRENT**<br>**CONSTANT CURRENT**<br>**REGION Note.3**<br>**DIMMING RANGE**<br>**SETUP, RISE TIME**<br>**Note.5,6**<br>**RATED POWER Note.4**<br>**CURRENT RIPPLE**<br>**CURRENT ADJ.RANGE**<br>**(BY NFC)**<br>COLD START 10A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>100μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=90℃<br>110 ~ 305VAC 141 ~ 400VDC<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25<br>of ambient temperature.<br>℃<br>2. Output hiccups under no-load condition.<br>3. Please refer to “DRIVER METHODS OF LED MODULE”.<br>4. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>6. Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller which can support for DALI<br>power on function, otherwise the startup time will be higher than 0.5 second.<br>7. Efficiency is measured at 800mA/50V by NFC.<br>8. Standby power consumption is measured at 230VAC.<br>9.<br>.<br>Flicker is measured at full load with LED modules<br>10. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete<br>installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>11. RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations.<br>12. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75<br>or less.<br>℃<br>13. The ambient temperature de-rating of 3.5<br>/1000m with fanless models and 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>.<br>14 To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.<br>15. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>16. For more information, please contact with MEAN WELL sales.<br>Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>※<br>Hiccup mode,recovers automatically after fault condition is removed<br>THD<10%(@load<br>50%/230VAC; @load<br>75%/277VAC), THD<15%(@load<br>50%/115VAC)<br>≧<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>Tcase=-25 ~ 90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**XLN-40-H-**<br>60V<br>0.6~1.4A<br>40W<br>1050mA<br>9~54V<br><4%<br>0~100%<br>88%<br>Blank & B type: De-rating to lowest output level. Recovers automatically after fault condition is removed.<br>114*44*32mm (L*W*H)<br>**SAFETY STANDARDS**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>**FLICKER Note.9**<br>PstLM<br>1, SVM<br>0.4<br>≤<br>≤<br>**STANDBY POWER**<br>**CONSUMPTION Note.8**<br>Standby power consumption<0.5W(Dimming off)<br>**DALI STANDARDS**<br>Comply with IEC62386-101,102,207<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>**CURRENT TOLERANCE**<br>±5%<br>3935.2 K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>342.9 Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>311g;60pcs / 13.44Kg / 95CUFT<br>0.<br>BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV),<br>EAC TP TC 020<br>BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load>50%); BS EN/EN61000-3-3; GB17625.1,<br>GB/T17743, EAC TP TC 020<br>ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(<br>DC);<br>���������������<br>BS EN/EN62384, GB19510.14, GB19510.1, EAC TP TC 004,<br>(Type HL and Class P)<br>approved<br>UL8750<br>; CSA C22.2 No. 250.13-12<br>;<br>Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13 ;|**XLN-40-H-**| |---|---|---| ||**OPEN CIRCUIT**<br>**VOLTAGE Note.2**|60V| ||**DEFAULT CURRENT**|1050mA| ||**CURRENT ADJ.RANGE**<br>**(BY NFC)**|0.6~1.4A| ||**CONSTANT CURRENT**<br>**REGION Note.3**|9~54V| ||**RATED POWER Note.4**|40W| ||**CURRENT RIPPLE**|<4%| ||**CURRENT TOLERANCE**|±5%| ||**DIMMING RANGE**|0~100%| ||**SETUP, RISE TIME**<br>**Note.5,6**|500ms, 100ms/230VAC, 1000ms, 100ms/115VAC| ||**VOLTAGE RANGE**|110 ~ 305VAC 141 ~ 400VDC| ||**FREQUENCY RANGE**|47 ~ 63Hz| ||**POWER FACTOR**<br>**EFFICIENCY (Typ.) Note.7**<br>**TOTAL HARMONIC DISTORTION**|THD<10%(@load<br>50%/230VAC; @load<br>75%/277VAC), THD<15%(@load<br>50%/115VAC)<br>≧<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>88%<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)| ||**AC CURRENT**|0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC| ||**INRUSH CURRENT(Typ.)**|COLD START 10A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>100μ<br>;Per NEMA 410| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC| ||**STANDBY POWER**<br>**CONSUMPTION Note.8**|Standby power consumption<0.5W(Dimming off)| ||**OVER TEMPERATURE**<br>**SHORT CIRCUIT**|Hiccup mode,recovers automatically after fault condition is removed| |||Blank & B type: De-rating to lowest output level. Recovers automatically after fault condition is removed.| |||DA2 type: Stage 1: De-ratingto 75% loading; Stage 2: De-ratingto 50% loading. Recovers automaticallyafter fault condition is removed.| ||**WORKING TEMP.**|Tcase=-25 ~ 90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃| ||**MAX. CASE TEMP.**|Tcase=90℃| ||**WORKING HUMIDITY**|20 ~ 90% RH non-condensing| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +<br>, 10 ~ 95% RH<br>80℃| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 50<br>)| ||**VIBRATION**|10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes| ||**SAFETY STANDARDS**|ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(<br>DC);<br>���������������<br>BS EN/EN62384, GB19510.14, GB19510.1, EAC TP TC 004,<br>(Type HL and Class P)<br>approved<br>UL8750<br>; CSA C22.2 No. 250.13-12<br>;<br>Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13 ;| ||**DALI STANDARDS**|Comply with IEC62386-101,102,207| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC| ||**ISOLATION RESISTANCE**|I/P-O/P:>100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃| ||**EMC EMISSION**|BS EN/EN55015, BS EN/EN61000-3-2 Class C (@load>50%); BS EN/EN61000-3-3; GB17625.1,<br>GB/T17743, EAC TP TC 020| ||**EMC IMMUNITY**|BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level(surge immunity Line-Line 1KV),<br>EAC TP TC 020| ||**FLICKER Note.9**|PstLM<br>1, SVM<br>0.4<br>≤<br>≤| ||**MTBF**|3935.2 K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>342.9 Khrs min. MIL-HDBK-217F (25<br>)<br>℃| ||**DIMENSION**|114*44*32mm (L*W*H)| ||**PACKING**<br>1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25<br>of ambient temperature.<br>℃<br>2. Output hiccups under no-load condition.<br>3. Please refer to “DRIVER METHODS OF LED MODULE”.<br>4. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>6. Based on IEC 62386-101/102 DALI power on timing and interruption regulations, the set up time needs to test with a DALI controller which can support for DALI<br>power on function, otherwise the startup time will be higher than 0.5 second.<br>7. Efficiency is measured at 800mA/50V by NFC.<br>8. Standby power consumption is measured at 230VAC.<br>9.<br>.<br>Flicker is measured at full load with LED modules<br>10. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete<br>installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)<br>11. RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations.<br>12. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75<br>or less.<br>℃<br>13. The ambient temperature de-rating of 3.5<br>/1000m with fanless models and 5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>℃<br>℃<br>.<br>14 To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.<br>15. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>16. For more information, please contact with MEAN WELL sales.<br>Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx<br>※<br>311g;60pcs / 13.44Kg / 95CUFT<br>0.|| _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** 40W Multiple-Stage Constant Power/Constant Voltage LED Driver ## **BLOCK DIAGRAM** **==> picture [453 x 109] intentionally omitted <==** **----- Start of picture text -----**<br> EMI FILTER POWER RECTIFIERS +V<br>I/P & SWITCHING & DC to DC -V<br>RECTIFIERS FILTER<br>O.T.P. CURRENT & DA+/PUSH<br>VOLTAGE LIMIT DA-/N<br>DETECTION<br>PWM&PFC<br>O.L.P. CIRCUIT<br>CONTROL<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** **==> picture [259 x 201] intentionally omitted <==** **----- Start of picture text -----**<br> -<br>※ ���������������<br>◎ XLN-40-H<br>For 40W application<br>60V<br>55V 600mA, 54V 700mA, 54V<br>50V<br>45V<br>40V<br>1050mA, 38V<br>35V<br>1400mA, 28.6V<br>30V<br>25V<br>20V<br>15V<br>10V<br>600mA, 9V 1400mA, 9V<br>5V<br>0V<br>400mA 500mA 600mA 700mA 800mA 900mA 1000mA1100mA 1200mA1300mA1400mA1500mA<br>**----- End of picture text -----**<br> ## **CONSTANT POWER TABLE** XLN-40-H is a multiple-stage constant power driver, selection of output current through NFC setting is exhibited below. **==> picture [106 x 154] intentionally omitted <==** **----- Start of picture text -----**<br> Vo Io<br>9~54V 600mA<br>9~54V 700mA<br>9~50V 800mA<br>9~45V 900mA<br>9~38V 1050mA(default)<br>9~33V 1200mA<br>9~31V 1300mA<br>9~29V 1400mA<br>**----- End of picture text -----**<br> Note: 1.The operating voltage range which show on this table is recommend to use. _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** 40W Multiple-Stage Constant Power/Constant Voltage LED Driver ## **NFC Function Description** 1. The output current of the NFC Mode LED driver can be adjusted using NFC via the mobile APP. Operation Instruction: ●Compatible phone - Install an NFC-compatible smart mobile device or phone with AndroidTM 4.1 or IOS12 updates. - ●Steps for setting output current via NFC 1. Download Meanwell APP on mobile device or mobile phone, and enable NFC function - , . 2. Check the NFC antenna position of the mobile phone please. - - 3. Enter Meanwell APP ->Top left menu Installation Manual/APP->PowerNFC,approach the LED driver NFC sensing position and perform sensing. 4. APP displays the functional parameters, and the relevant parameters are modified as required. 5. Tap the APP write button and quickly move the phone antenna close to the NFC sensing position of the LED driver. 6. The write completes when the mobile phone displays"Success". **==> picture [483 x 275] intentionally omitted <==** **----- Start of picture text -----**<br> ※ APP Interface:<br>10:34 HO Leos ile 10:34 HOw 2m = fil<br>«K Power NFC cw < Power NFC 2)<br>Model name > —_ — > XL0-25-H-DA2-N Read<br>Adjustable Output ——»> Current Output CurrentLevel<br>Current | Current Setting+ [708 Jma Setting 708mA | <— _<br>NFC Setting GTIN<br>password<br>_) Address Accumulating Back<br>Device address<br>\~15<br>Factory setting td Default | Write<br>Setting to LED Driver<br>**----- End of picture text -----**<br> - •To be used through APP available on Apple Store and Google Play Store for iOS and Android. Search: MEAN WELL on Note. Current accuracy : the numerical error between the set current and the actual current is within 2%. _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** 40W Multiple-Stage Constant Power/Constant Voltage LED Driver ## **DIMMING OPERATION** ## ◎ **B type** - ※ **3 in 1 dimming function** - •Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance. - •Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. •Dimming source current from power supply: 100μA (typ.) **==> picture [443 x 486] intentionally omitted <==** **----- Start of picture text -----**<br> 100%<br>90%<br>80%<br>+<br>+V + 70%<br>60%<br>-<br>-V - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to -V" 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>+<br>+V + 70%<br>60%<br>-<br>-V - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to -V" 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>◎ Applying additive resistance: 0~100kΩ 100%<br>90%<br>+V + + 80%<br>70%<br>-<br>-V - 60%<br>DIM+ 50%<br>40%<br>Additive Resistance<br>30%<br>DIM- 20%<br>“DO NOT connect "DIM- to -V" 10%<br>0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Note : 1. Min. dimming level is about 6% and the output current is not defined when 0%< Iout<6%.<br>2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** ## 40W Multiple-Stage Constant Power/Constant Voltage LED Driver ## **DIMMING OPERATION** **==> picture [407 x 361] intentionally omitted <==** **----- Start of picture text -----**<br> ◎ DA2 type (DALI-2 digital dimming function)<br>※ Input wiring diagram<br>DA+/PUSH(PURPLE)<br>DA-/N(PINK)<br>UL2517(18AWG*2)<br>AC/L XLN-40-H-DA2<br>AC/N<br>AC/L(BROWN)AC/N(BLUE) SJOW 17AWG×2C & H05RN-F 2×1.0mm2<br>DA+/PUSH(PURPLE)<br>DA-/N(PINK) UL2517(18AWG*2)<br>DA+<br>DA-<br>AC/L XLN-40-H-DA2<br>AC/N<br>AC/L(BROWN)AC/N(BLUE) SJOW 17AWG×2C & H05RN-F 2×1.0mm2<br>※ PUSH dimming (primary side)<br>• The factory default dimming level is at 100%.<br>• If the push action lasts less than 0.05 sec., it will not lead to a change for the status of the driver.<br>• Up to 10 drivers can perform the PUSH dimming at the same time when utilizing one common push button.<br>• The maximum length of the cable from the push button to the last driver is 20 meters.<br>Action Action duration Function<br>Short Push 0.1~1s Turn ON-OFF the driver<br>Double Click Click twice in 1.5s Set up the dimming level to 100%<br>Long Push 1.5~10s Every Long Push changes the dimming direction, dimming up or down<br>**----- End of picture text -----**<br> _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** 40W Multiple-Stage Constant Power/Constant Voltage LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [220 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>230 VAC<br>60<br>110VAC<br>40<br>20<br>-25 -15 0 15 30 40 50 60 70 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ )<br>LOAD (%)<br>**----- End of picture text -----**<br> **==> picture [227 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>40<br>20<br>-25 0 20 45 55 65 75 85 90 (HORIZONTAL)<br>Tcase ( ℃ )<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **STATIC CHARACTERISTIC** **==> picture [193 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>90<br>80<br>70<br>60<br>50<br>40<br>100 110 130 150 170 190 210 230 250 270 290 305<br>INPUT VOLTAGE (V) 60Hz<br>※De-rating is needed under low input voltage.<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **LIFE TIME** **==> picture [361 x 207] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>25 35 45 55 65 75 85<br>�����( )℃<br>(Kh)<br>LIFETIME<br>**----- End of picture text -----**<br> _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** 40W Multiple-Stage Constant Power/Constant Voltage LED Driver **==> picture [482 x 618] intentionally omitted <==** **----- Start of picture text -----**<br> TOTAL HARMONIC DISTORTION (THD)<br>※ XLN-40-H Model,Tcase at 75℃<br>12 12<br>10 10<br>8 8<br>115VAC 115VAC<br>6 230VAC 6 230VAC<br>277VAC 277VAC<br>4 4<br>2 2<br>0 0<br>50% 60% 70% 80% 90% 100% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>(1050mA) (1400mA)<br>POWER FACTOR (PF) CHARACTERISTIC<br>※ XLN-40-H Model,Tcase at 75℃<br>1 1<br>0.98 0.98<br>0.96 0.96<br>0.94 0.94<br>0.92 0.92<br>0.9 115VAC 0.9 115VAC<br>230VAC 230VAC<br>0.88 0.88<br>277VAC 277VAC<br>0.86 0.86<br>0.84 0.84<br>0.82 0.82<br>0.8 0.8<br>50% 60% 70% 80% 90% 100% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>(1050mA) (1400mA)<br>EFFICIENCY vs LOAD<br>XLN-40 series possess superior working efficiency that up to 88% can be reached in field applications.<br>※ XLN-40-H Model,Tcase at 75℃<br>90 90<br>85 85<br>80 80<br>75 75<br>70 115VAC 70 115VAC<br>230VAC 230VAC<br>65 277VAC 65 277VAC<br>60 60<br>55 55<br>50 50<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>(1050mA) (1400mA)<br>THD(%) THD(%)<br>PF PF<br>EFFICIENCY (%) EFFICIENCY (%)<br>**----- End of picture text -----**<br> _File Name:XLN-40-SPEC 2024-03-21_ **- XLN 40 series** ## 40W Multiple-Stage Constant Power/Constant Voltage LED Driver **==> picture [499 x 549] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION<br>Case No.XLN-25 Unit:mm<br>※ ����������<br>150 mm 114 mm 150 mm<br>106 mm<br>( )<br>56.1 mm ��<br>AC/L(BROWN)<br>AC/N(BLUE)<br>SJOW 17AWG×2C & H05RN-F 2×1.0mm2 SJOW 17AWG×2C & 05RN-F 2×1.0mm2 -V(BLACK)+V(RED)<br>※ ������<br>150 mm 114 mm 150 mm<br>SJOW 17AWG×2C & 05RN-F 2×1.0mm2<br>( ) -V(BLACK)<br>56.1 mm �� +V(RED)<br>AC/L(BROWN)<br>AC/N(BLUE)<br>SJOW 17AWG×2C & H05RN-F 2×1.0mm2 UL2517(18AWG*2) DIM-(PINK)<br>DIM+(PURPLE)<br>180 mm<br>※ �A2 ����<br>DA+/PUSH 180 mm 114 mm 150 mm<br>(PURPLE) UL2517(18AWG*2)<br>( )<br>DA-/N(PINK) 56.1 mm ��<br>AC/L(BROWN)AC/N(BLUE) SJOW 17AWG×2C & 05RN-F 2×1.0mm2 -V(BLACK)<br>SJOW 17AWG×2C & H05RN-F 2×1.0mm2 +V(RED)<br>3.6<br>ψ<br>23.1 mm<br>23.1 mm<br>23.1 mm<br>44 mm 36 mm<br>32 mm<br>44 mm<br>32 mm<br>44 mm<br>32 mm<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:XLN-40-SPEC 2024-03-21_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →