Image not available
Illustrative purposes only
XLG-25-A
LED Driver, 25 W, 54 VDC, 700 mA, Constant Current, Constant Voltage, 90 V
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- Output Power Max:25W; Output Voltage Max:54V; Output Current:700mA; LED Driver Mode:Constant Current, Constant Voltage; Input Voltage Min:90V; Input Voltage Max:305V; Product Range:XLG-2
- SVHC: No SVHC (25-Jun-2025)
- Product Range: XLG-25
- Output Current: 700mA
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 25W
- Input Voltage Max: 305V
- Input Voltage Min: 90V
- Output Voltage Max: 54VDC
- Power Supply Applications: -
| Delivery and price | |
|---|---|
| Units per pack | 250 |
| Price | 17.57 € |
| Current stock | 10+ |
| Lead time | 30 days |
**XLG - 25 series** 25W Constant Power Mode LED Driver **==> picture [520 x 405] intentionally omitted <==** **----- Start of picture text -----**<br> IP67 05<br>8 O W W W seLv ®4 Wis K CBCE<br>■ Features ■ Applications<br>• •<br>Constant Power mode output LED street lighting<br>• •<br>Metal housing design with functional Ground LED architectural lighting<br>• •<br>Built-in active PFC function LED bay lighting<br>• •<br>Class 2 power unit LED floodlighting<br>• •<br>No load / Standby power consumption <0.5W Type “HL” for use in Class I, Division 2<br>• IP67 rating for indoor or outdoor installations hazardous (Classified) location.<br>• Function options: output adjustable via potentiometer<br>3 in 1 dimming (dim-to-off)<br>• Typical lifetime>50000 hours<br>• 5 years warranty<br>■ Description<br>XLG-25 series is a25W AC/DC LED driver featuring the constant power mode output. XLG-25 operates<br>from 100~305VAC. Thanks to the high efficiency up to 88%, The entire series is able to operate between<br>-40 ℃ ~85 ℃ wide case temperature range with air convection. The design of metal housing and IP67<br>ingress protection level allows this series to fit both indoor and outdoor applications.XLG-25 is equipped<br>with various function options, such as dimming methodologies, so as to provide the optimal design<br>flexibility for LED lighting system.<br>■ Model Encoding<br>XLG - 25[1]- [A]<br>nr T= Function mode option<br>I: for India only<br>{ [_] : None<br>**----- End of picture text -----**<br> _File Name:XLG-25-SPEC 2018-11-16_ **XLG - 25 series** ## 25W Constant Power Mode LED Driver ## **SPECIFICATION** |**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**Note.10**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP.**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>500ms, 100ms/115VAC, 230VAC<br>47 ~ 63Hz<br>0.29A / 115VAC 0.15A / 230VAC 0.13A/277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>105 63<br>*<br>*30mm (L*W*H)<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>88%<br>**TOTAL HARMONIC DISTORTION**<br>**RATED CURRENT**<br>**RATED POWER**<br>**Note.5**<br>**CURRENT ADJ. RANGE**<br>**SETUP, RISE TIME**<br>**Note.3**<br>**OPEN CIRCUIT VOLTAGE (max.)**<br>**CONSTANT CURRENT REGION Note.2**<br>**SAFETY STANDARDS**<br>COLD START 50A(twidth=350 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+85℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (<br>)<br>surge immunity Line-Earth 6KV, Line-Line 4KV<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC<br>℃<br>℃<br>℃<br>℃<br>110-150% Over Power Protection, recovers automatically after fault condition is removed<br>Constant current limiting, recovers automatically after fault condition is removed<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>No load power consumption <0.5W for A,<0.75W for I series<br>**NO LOAD / STANDBY**<br>**POWER CONSUMPTION**<br>Standby power consumption <0.5W for AB<br>Tcase=-40 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>UL8750<br>ENEC AS/NZS IEC EN61347-1, AS/NZS EN61347-2-13 independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>IP65 or IP67;<br>approved<br>GB19510.1, GB19510.14<br>Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;<br>≧<br>GB17743, GB17625.1<br>1305.62 K hrs min. Telcordia SR-332 (Bellcore) 399.88Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>**XLG-25**<br>0.25 ~ 1.05A<br>22 ~54V<br>25W<br>700mA<br>90VAC ~ 305VAC<br>57V<br>5.0%<br>@<br>max.<br>rated current<br>**CURRENT RIPPLE**<br>**OVER TEMPERATURE**<br>Hiccup mode, recovers automatically after fault condition is removed<br>**INPUT OVER VOLTAGE Note.8** 320 ~ 370<br>(Shut down output voltage when the input voltage exceeds protection voltage)<br>VAC<br>can survive input voltage stress of 440Vac for 48 hours<br>**SHORT CIRCUIT**<br>**OVER POWER**<br>0.41Kg;24pcs/ 10.5Kg/0.68CUFT for A-type 0.42Kg;24pcs/ 11Kg/0.68CUFT for AB-type<br>a<br>~~Ce~~<br>~~Ce~~<br>a<br>a<br>a<br>Re<br>a<br>a<br>a<br>ee<br>a<br>a<br>a<br>a ~~PO~~<br>~~Ce~~<br>~~eG~~<br>a~~ee~~<br>a<br>a<br>a<br>a<br>a<br>a<br>Re<br>~~ee~~<br>a<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated current and 25 —_ofambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>4. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. This series meetsthetypical lifeexpectancy of>50,000 hours of operationwhen Tcase, particularly(©)point (orTMP, per DLC), is about70<br>or less.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~htto:/Avwww.meanwell.com~~<br>8. Only for XLG-25<br>| series<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Only for XLG-25-A<br>11. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~https:/Avww.meanwell.com/Upload/PDF/LED_EN.padf~~|**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**Note.10**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**EMC IMMUNITY**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP.**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>500ms, 100ms/115VAC, 230VAC<br>47 ~ 63Hz<br>0.29A / 115VAC 0.15A / 230VAC 0.13A/277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>105 63<br>*<br>*30mm (L*W*H)<br>**ENVIRONMENT**<br>**EMC EMISSION**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>88%<br>**TOTAL HARMONIC DISTORTION**<br>**RATED CURRENT**<br>**RATED POWER**<br>**Note.5**<br>**CURRENT ADJ. RANGE**<br>**SETUP, RISE TIME**<br>**Note.3**<br>**OPEN CIRCUIT VOLTAGE (max.)**<br>**CONSTANT CURRENT REGION Note.2**<br>**SAFETY STANDARDS**<br>COLD START 50A(twidth=350 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+85℃<br>Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (<br>)<br>surge immunity Line-Earth 6KV, Line-Line 4KV<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC<br>℃<br>℃<br>℃<br>℃<br>110-150% Over Power Protection, recovers automatically after fault condition is removed<br>Constant current limiting, recovers automatically after fault condition is removed<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)<br>THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)<br>No load power consumption <0.5W for A,<0.75W for I series<br>**NO LOAD / STANDBY**<br>**POWER CONSUMPTION**<br>Standby power consumption <0.5W for AB<br>Tcase=-40 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>UL8750<br>ENEC AS/NZS IEC EN61347-1, AS/NZS EN61347-2-13 independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>IP65 or IP67;<br>approved<br>GB19510.1, GB19510.14<br>Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;<br>≧<br>GB17743, GB17625.1<br>1305.62 K hrs min. Telcordia SR-332 (Bellcore) 399.88Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>**XLG-25**<br>0.25 ~ 1.05A<br>22 ~54V<br>25W<br>700mA<br>90VAC ~ 305VAC<br>57V<br>5.0%<br>@<br>max.<br>rated current<br>**CURRENT RIPPLE**<br>**OVER TEMPERATURE**<br>Hiccup mode, recovers automatically after fault condition is removed<br>**INPUT OVER VOLTAGE Note.8** 320 ~ 370<br>(Shut down output voltage when the input voltage exceeds protection voltage)<br>VAC<br>can survive input voltage stress of 440Vac for 48 hours<br>**SHORT CIRCUIT**<br>**OVER POWER**<br>0.41Kg;24pcs/ 10.5Kg/0.68CUFT for A-type 0.42Kg;24pcs/ 11Kg/0.68CUFT for AB-type<br>a<br>~~Ce~~<br>~~Ce~~<br>a<br>a<br>a<br>Re<br>a<br>a<br>a<br>ee<br>a<br>a<br>a<br>a ~~PO~~<br>~~Ce~~<br>~~eG~~<br>a~~ee~~<br>a<br>a<br>a<br>a<br>a<br>a<br>Re<br>~~ee~~<br>a<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated current and 25 —_ofambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>4. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. This series meetsthetypical lifeexpectancy of>50,000 hours of operationwhen Tcase, particularly(©)point (orTMP, per DLC), is about70<br>or less.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~htto:/Avwww.meanwell.com~~<br>8. Only for XLG-25<br>| series<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Only for XLG-25-A<br>11. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~https:/Avww.meanwell.com/Upload/PDF/LED_EN.padf~~|**XLG-25**| |---|---|---| ||**RATED CURRENT**<br>a|700mA| ||**CONSTANT CURRENT REGION Note.2**<br>a|22 ~54V| ||**RATED POWER**<br>**Note.5**<br>a|25W<br>90VAC ~ 305VAC<br>~~Ce~~<br>~~Ce~~| ||**CURRENT RIPPLE**<br>a|5.0%<br>@<br>max.<br>rated current<br>~~Ce~~| ||**OPEN CIRCUIT VOLTAGE (max.)**<br>a<br>a|57V<br>~~Ce~~| ||**CURRENT ADJ. RANGE**<br>a<br>a<br>Re|0.25 ~ 1.05A| ||**SETUP, RISE TIME**<br>**Note.3**<br>Re|500ms, 100ms/115VAC, 230VAC| ||**VOLTAGE RANGE**<br>**Note.5**<br>Re|(Please refer to "STATIC CHARACTERISTIC" section)<br>90 ~ 305VAC| ||**FREQUENCY RANGE**<br>a|47 ~ 63Hz| ||**POWER FACTOR**<br>a|PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)| ||**TOTAL HARMONIC DISTORTION**<br>a|THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)| ||**EFFICIENCY (Typ.)**<br>**Note.10**<br>a<br>a|88%| ||**AC CURRENT**<br>a<br>a<br>ee|0.29A / 115VAC 0.15A / 230VAC 0.13A/277VAC| ||**INRUSH CURRENT(Typ.)**<br>a<br>ee|COLD START 50A(twidth=350 s measured at 50% Ipeak) at 230VAC<br>μ<br>;Per NEMA 410| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>ee|5 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC| ||**LEAKAGE CURRENT**<br>a|<0.75mA / 277VAC| ||**NO LOAD / STANDBY**<br>**POWER CONSUMPTION**|No load power consumption <0.5W for A,<0.75W for I series<br>Standby power consumption <0.5W for AB| ||**OVER POWER**<br>a|110-150% Over Power Protection, recovers automatically after fault condition is removed| ||**SHORT CIRCUIT**<br>a<br>a|Constant current limiting, recovers automatically after fault condition is removed| ||**OVER TEMPERATURE**<br>a<br>a|Hiccup mode, recovers automatically after fault condition is removed<br>| ||**INPUT OVER VOLTAGE Note.8** <br>a|320 ~ 370<br>(Shut down output voltage when the input voltage exceeds protection voltage)<br>VAC<br>can survive input voltage stress of 440Vac for 48 hours<br> ~~PO~~<br>~~Ce~~| ||**WORKING TEMP.**<br>~~eG~~<br>a|Tcase=-40 ~ +85<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>~~Ce~~<br>~~eG~~<br>| ||**MAX. CASE TEMP.**<br>a|Tcase=+85℃<br>| ||**WORKING HUMIDITY**<br>a~~ee~~<br>a|20 ~ 95% RH non-condensing<br>~~ee~~| ||**STORAGE TEMP.**<br>a<br>a|-40 ~ +80℃| ||**TEMP. COEFFICIENT**<br>a<br>a|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)| ||**VIBRATION**<br>a<br>a|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes| ||**SAFETY STANDARDS**<br>a|UL8750<br>ENEC AS/NZS IEC EN61347-1, AS/NZS EN61347-2-13 independent, EN62384;<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>IP65 or IP67;<br>approved<br>GB19510.1, GB19510.14| ||**WITHSTAND VOLTAGE**<br>a<br>a|I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC| ||**ISOLATION RESISTANCE**<br>a|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃| ||**EMC EMISSION**<br>a<br>a<br>Re|Compliance to EN55015,EN61000-3-2 Class C (@load<br>50%) ; EN61000-3-3;<br>≧<br>GB17743, GB17625.1| ||**EMC IMMUNITY**<br>a<br>Re|Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (<br>)<br>surge immunity Line-Earth 6KV, Line-Line 4KV| ||**MTBF**<br>Re<br>~~ee~~<br>a|1305.62 K hrs min. Telcordia SR-332 (Bellcore) 399.88Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~ee~~| ||**DIMENSION**<br>a|105 63<br>*<br>*30mm (L*W*H)| ||**PACKING**<br>a<br>a|0.41Kg;24pcs/ 10.5Kg/0.68CUFT for A-type 0.42Kg;24pcs/ 11Kg/0.68CUFT for AB-type| ||℃<br>℃<br>℃<br>℃<br>a<br>1. All parametersNOT specially mentioned are measured at230VAC input, rated current and 25 —_ofambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>4. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>6. This series meetsthetypical lifeexpectancy of>50,000 hours of operationwhen Tcase, particularly(©)point (orTMP, per DLC), is about70<br>or less.<br>7. Please refer to the warranty statement on MEAN WELL's website at ~~htto:/Avwww.meanwell.com~~<br>8. Only for XLG-25<br>| series<br>9. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Only for XLG-25-A<br>11. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~https:/Avww.meanwell.com/Upload/PDF/LED_EN.padf~~|| _File Name:XLG-25-SPEC 2018-11-16_ **XLG - 25 series** 25W Constant Power Mode LED Driver ## **Block Diagram** **==> picture [464 x 148] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>EMI FILTER PFC POWER RECTIFIERS Vo+<br>I/P & CIRCUIT SWITCHING & Vo-<br>RECTIFIERS FILTER<br>O.L.P.<br>O.T.P. O.L.P. DETECTION<br>PWM & PFC CIRCUIT<br>CONTROL<br>CASE :Protective Earth<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** **==> picture [334 x 218] intentionally omitted <==** **----- Start of picture text -----**<br> 54V<br>250mA, 54V 500mA,54V<br>48V<br>42V<br>36V 700mA,36V<br>30V<br>24V 1050mA, 24V<br>18V<br>250mA,22V 500mA, 22V 1050mA, 22V<br>12V<br>6V<br>0V<br>0mA 175mA 350mA 525mA 700mA 875mA 1050mA 1225mA<br>High Performance Region Operational Region<br>**----- End of picture text -----**<br> _File Name:XLG-25-SPEC 2018-11-16_ **XLG - 25 series** 25W Constant Power Mode LED Driver ## **DIMMING OPERATION** **==> picture [476 x 629] intentionally omitted <==** **----- Start of picture text -----**<br> AC/N(Blue) Vo-(Red)<br>AC/L(Brown) XLG-25 Vo+(Black) DIM+(Blue)<br>PE (Green/Yellow) DIM-(White)<br>※ 3 in 1 dimming function (for AB-Type)<br>•Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:<br>0 ~ 10VDC, or 10V PWM signal or resistance.<br>•Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.<br>•Dimming source current from power supply: 100μA (typ.)<br>◎ Applying additive 0 ~ 10VDC 100%<br>88%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100%<br>88%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 88% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>◎ Applying additive resistance: 100%<br>88%<br>Vo+ + + 80%<br>70%<br>-<br>Vo- - 60%<br>DIM+ 50%<br>40%<br>Additive Resistance<br>30%<br>DIM- 20%<br>“DO NOT connect "DIM- to Vo-" 10%<br>0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.<br>2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> _File Name:XLG-25-SPEC 2018-11-16_ **XLG - 25 series** 25W Constant Power Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [487 x 375] intentionally omitted <==** **----- Start of picture text -----**<br> 100 100<br>80 80<br>230VAC 230VAC<br>input only input only<br>60 60<br>40 40<br>20 20<br>-40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -25 0 20 45 55 65 75 85 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>Constant Current Mode<br>100<br>1<br>90<br>0.95<br>80 0.9<br>0.85<br>70 0.8 277V(25W)<br>60 0.75 230V(25W)<br>0.7<br>115V(25W)<br>50 0.65<br>0.6<br>40<br>0.55<br>0.5<br>90 100 120 140 160 180 200 220 240 260 280 305 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>INPUT VOLTAGE (V) 60Hz LOAD<br>※De-rating is needed under low input voltage.<br>LOAD (%) LOAD (%)<br>PF<br>LOAD (%)<br>**----- End of picture text -----**<br> ## **TOTAL HARMONIC DISTORTION (THD)** ## **EFFICIENCY vs LOAD** XLG-25 series possess superior working efficiency that up to 88% can be reached in field applications. **==> picture [509 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> ※ 50V Model, Tcase at 75℃<br>※ 50V Model, Tcase at 75℃<br>10<br>92<br>9 90<br>8 88<br>7 86<br>84<br>6 82 277V(25W)<br>5 115VAC(25W) 80 230V(25W)<br>4 230VAC(25W) 78 115V(25W)<br>76<br>3<br>277VAC(25W) 74<br>2 72<br>1 70<br>0 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>50% 60% 70% 80% 90% 100%<br>LOAD LOAD<br>THD(%)<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:XLG-25-SPEC 2018-11-16_ **XLG - 25 series** 25W Constant Power Mode LED Driver ## **LIFE TIME** **==> picture [373 x 271] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>20 30 40 50 60 70 80 85<br>Tcase ( )℃<br>(Kh)<br>LIFETIME<br>**----- End of picture text -----**<br> _File Name:XLG-25-SPEC 2018-11-16_ **XLG - 25 series** ## 25W Constant Power Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>CASE NO.: 268A Unit:mm<br>※ A-Type<br>105<br>99<br>300±10 90 300±10<br>AC/L(Brown)AC/N(Blue) tc 61.3 Vo-(Black)<br>PE (Green/Yellow) Vo+(Red)<br>SJOW 17AWGx3C SJOW 17AWGx2C<br>&H05RN-F 3x1.0mm2 &05RN-F 2x1.0mm2<br>4-ψ4.5<br>•tc : Max. Case Temperature<br>25.8<br>30<br>31.6<br>40 63<br>9.9<br>**----- End of picture text -----**<br> _File Name:XLG-25-SPEC 2018-11-16_ **XLG - 25 series** ## 25W Constant Power Mode LED Driver **==> picture [471 x 295] intentionally omitted <==** **----- Start of picture text -----**<br> ※ AB-Type<br>105<br>99<br>300±10 90 300±10<br>SJOW 17AWGx2C<br>&05RN-F 2x1.0mm2<br>Vo-(Black)<br>AC/N(Blue) tc 61.3 Vo+(Red)<br>PE AC/L(Brown)(Green/Yellow) DIM+(Blue)<br>&H05RN-F 3x1.0mmSJOW 17AWGx3C 2 UL2517 20AWGx2C DIM-(White)<br>4-ψ4.5 325±10<br>•tc : Max. Case Temperature<br>25.8<br>30<br>31.6<br>40 63<br>9.9<br>**----- End of picture text -----**<br> ## **Installation Manual** **==> picture [177 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html<br>**----- End of picture text -----**<br> _File Name:XLG-25-SPEC 2018-11-16_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →