- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (12-Jan-2017)
- Product Range: XLG-240
- Output Current: 10A
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 240W
- Input Voltage Max: 305V
- Input Voltage Min: 100V
- Output Voltage Max: 24VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 29.37 € |
| Current stock | 10+ |
| Lead time | 30 days |
**XLG - 240 series** 240W Constant Power Mode LED Driver **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [264 x 43] intentionally omitted <==** **----- Start of picture text -----**<br> IP67 05<br>WO AWs < CBHICE Note.13<br>■ Applications<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [45 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> ℃ ℃<br>**----- End of picture text -----**<br> **==> picture [13 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [135 x 25] intentionally omitted <==** **----- Start of picture text -----**<br> |: for India version<br>{ [_] : For standard version<br>**----- End of picture text -----**<br> _File Name:XLG-240-SPEC 2019-03-13_ **XLG - 240 series** 240W Constant Power Mode LED Driver ## **SPECIFICATION** |**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>500ms, 100ms/230VAC, 1200ms, 100ms/115VAC<br>10ms/ 230VAC 10ms/ 115VAC<br>47 ~ 63Hz<br>2.7A / 115VAC 1.3A / 230VAC 1.1A/277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>90℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**PROTECTION**<br>Shut down output voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.6**<br>**HOLD UP TIME (Typ.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>**CONSTANT CURRENT REGION Note.2**<br>**OVER CURRENT**<br>COLD START 75A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>500μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC<br>95 ~ 108%<br>Hiccup mode,recovers automatically after fault condition is removed<br>Constant current limiting, recovers automatically after fault condition is removed<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**XLG-240-12-**<br>12V<br>18A<br>180mVp-p<br>8.4~ 12V<br>216W<br>±3.0%<br>±0.5%<br>±2%<br>92%<br>13.5 ~ 18V<br>219 63<br>*<br>*35.5mm (L*W*H)<br>1Kg;16pcs / 16Kg / 0.77CUFT<br>**SAFETY STANDARDS**<br>UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; IP67 approved<br>**XLG-240-24-**<br>24V<br>10A<br>240mVp-p<br>16.8~ 24V<br>240W<br>±2.0%<br>±0.5%<br>±1%<br>93.5%<br>27 ~ 34V<br>**NO LOAD**<br>**POWER CONSUMPTION**<br>No load power consumption <0.5W<br>**INPUT OVER VOLTAGE Note.7**<br>320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage)<br>can survive input voltage stress of 440Vac for 48 hours<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>9 ~ 18A<br>5 ~ 10A<br>Adjustable for A-Type only (via the built-in potentiometer)<br>**CURRENT ADJ. RANGE**<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2<br>**Standard**<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>4KV/Line-Line 6KV/Line-Earth<br>**NOTE**<br>℃<br>℃<br>℃<br>℃<br>830.77K hrs min.<br>Telcordia SR-332(Bellcore) ; 219.75K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>EN61000-3-2<br>EN61000-3-3<br>-----<br>-----<br>Class C @load≥50%<br>-----<br>EN55015(CISPR15)<br>EN55015(CISPR15)<br>~~a~~<br>~~RO~~<br>a<br>a<br>~~a~~<br>a<br>~~a~~<br>~~Ce~~<br>~~a~~<br>~~G~~<br>a<br>Rs<br>a<br>a<br>~~Ge~~<br>a~~Ce~~<br>~~ee~~<br>~~RG~~<br>a<br>Rs<br>~~Ce~~<br>Cn<br>~~a~~<br>~~Ce~~<br>~~|~~<br>~~Cn~~<br>~~|~~<br>Re<br>es<br>RR<br>a<br>RR<br>a<br>Rs<br>~~Ce~~<br>~~ee~~<br>~~eG~~<br>a<br>~~RO~~<br>a<br>~~O~~<br>~~RG~~<br>~~Cn~~<br>~~Ge~~<br>~~eG~~<br>~~Ge~~<br>~~es~~<br>a<br>a<br>a<br>~~GC~~<br>~~se~~<br>as<br>~~De~~<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7.Only for XLG-240<br>| series<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. This series meetsthe typical life expectancy of>50,000 hours of operation when Tcase, particularly© point (orTMP, per DLC), is about 70 _ or less.<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/(www.meanwell.com<br>11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to<br>the mains.<br>12. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>13.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>14.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~httos:/Avww.meanwell.com/Upload/PDF/LED_EN.padf~~|**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>500ms, 100ms/230VAC, 1200ms, 100ms/115VAC<br>10ms/ 230VAC 10ms/ 115VAC<br>47 ~ 63Hz<br>2.7A / 115VAC 1.3A / 230VAC 1.1A/277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>90℃<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**PROTECTION**<br>Shut down output voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.6**<br>**HOLD UP TIME (Typ.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>**CONSTANT CURRENT REGION Note.2**<br>**OVER CURRENT**<br>COLD START 75A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>500μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC<br>95 ~ 108%<br>Hiccup mode,recovers automatically after fault condition is removed<br>Constant current limiting, recovers automatically after fault condition is removed<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**XLG-240-12-**<br>12V<br>18A<br>180mVp-p<br>8.4~ 12V<br>216W<br>±3.0%<br>±0.5%<br>±2%<br>92%<br>13.5 ~ 18V<br>219 63<br>*<br>*35.5mm (L*W*H)<br>1Kg;16pcs / 16Kg / 0.77CUFT<br>**SAFETY STANDARDS**<br>UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; IP67 approved<br>**XLG-240-24-**<br>24V<br>10A<br>240mVp-p<br>16.8~ 24V<br>240W<br>±2.0%<br>±0.5%<br>±1%<br>93.5%<br>27 ~ 34V<br>**NO LOAD**<br>**POWER CONSUMPTION**<br>No load power consumption <0.5W<br>**INPUT OVER VOLTAGE Note.7**<br>320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage)<br>can survive input voltage stress of 440Vac for 48 hours<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>9 ~ 18A<br>5 ~ 10A<br>Adjustable for A-Type only (via the built-in potentiometer)<br>**CURRENT ADJ. RANGE**<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2<br>**Standard**<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>4KV/Line-Line 6KV/Line-Earth<br>**NOTE**<br>℃<br>℃<br>℃<br>℃<br>830.77K hrs min.<br>Telcordia SR-332(Bellcore) ; 219.75K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>EN61000-3-2<br>EN61000-3-3<br>-----<br>-----<br>Class C @load≥50%<br>-----<br>EN55015(CISPR15)<br>EN55015(CISPR15)<br>~~a~~<br>~~RO~~<br>a<br>a<br>~~a~~<br>a<br>~~a~~<br>~~Ce~~<br>~~a~~<br>~~G~~<br>a<br>Rs<br>a<br>a<br>~~Ge~~<br>a~~Ce~~<br>~~ee~~<br>~~RG~~<br>a<br>Rs<br>~~Ce~~<br>Cn<br>~~a~~<br>~~Ce~~<br>~~|~~<br>~~Cn~~<br>~~|~~<br>Re<br>es<br>RR<br>a<br>RR<br>a<br>Rs<br>~~Ce~~<br>~~ee~~<br>~~eG~~<br>a<br>~~RO~~<br>a<br>~~O~~<br>~~RG~~<br>~~Cn~~<br>~~Ge~~<br>~~eG~~<br>~~Ge~~<br>~~es~~<br>a<br>a<br>a<br>~~GC~~<br>~~se~~<br>as<br>~~De~~<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7.Only for XLG-240<br>| series<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. This series meetsthe typical life expectancy of>50,000 hours of operation when Tcase, particularly© point (orTMP, per DLC), is about 70 _ or less.<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/(www.meanwell.com<br>11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to<br>the mains.<br>12. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>13.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>14.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~httos:/Avww.meanwell.com/Upload/PDF/LED_EN.padf~~|**XLG-240-12-**|**XLG-240-12-**|**XLG-240-24-**|**XLG-240-24-**| |---|---|---|---|---|---| ||**DC VOLTAGE**<br>~~a~~|12V<br>~~a~~||24V<br>~~a~~|| ||**CONSTANT CURRENT REGION Note.2**<br>~~a~~<br>~~RO~~|8.4~ 12V<br>~~a~~<br>~~RO~~||16.8~ 24V<br>~~a~~<br>~~RO~~|| ||**RATED CURRENT**<br>a|18A||10A|| ||**RATED POWER**<br>a<br>a|216W<br>~~a~~||240W|| ||**RIPPLE & NOISE (max.) Note.3**<br>a<br>a|180mVp-p<br>~~a~~<br>~~a~~||240mVp-p|| ||**CURRENT ADJ. RANGE**<br>a|9 ~ 18A<br>5 ~ 10A<br>Adjustable for A-Type only (via the built-in potentiometer)<br>~~a~~<br>~~Ce~~<br>~~a~~<br>~~G~~|||| ||**VOLTAGE TOLERANCE Note.4**<br>a<br>Rs|±3.0%<br>~~a~~||±2.0%<br>~~G~~|| ||**LINE REGULATION**<br>a<br>Rs|±0.5%||±0.5%|| ||**LOAD REGULATION**<br>Rs<br>a|±2%||±1%|| ||**SETUP, RISE TIME**<br>**Note.6**<br>a<br>a|500ms, 100ms/230VAC, 1200ms, 100ms/115VAC|||| ||**HOLD UP TIME (Typ.)**<br>a<br>~~Ge~~|10ms/ 230VAC 10ms/ 115VAC<br>~~Ge~~|||| ||**VOLTAGE RANGE**<br>**Note.5**<br>~~Ge~~|(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC<br>~~Ge~~|||| ||**FREQUENCY RANGE**<br>a|47 ~ 63Hz<br>|||| ||**POWER FACTOR**<br>~~Ce~~|PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>~~Ce~~|||| ||**TOTAL HARMONIC DISTORTION**<br>~~ee~~|THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>~~ee~~|||| ||**EFFICIENCY (Typ.)**<br>~~ee~~<br>~~RG~~<br>a|92%<br>~~ee~~<br>~~RG~~||93.5%<br>~~ee~~<br>~~RG~~|| ||**AC CURRENT**<br>~~RG~~<br>a<br>Rs|2.7A / 115VAC 1.3A / 230VAC 1.1A/277VAC<br>~~RG~~|||| ||**INRUSH CURRENT(Typ.)**<br>a<br>Rs|COLD START 75A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>500μ<br>;Per NEMA 410|||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>Rs|3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC|||| ||**LEAKAGE CURRENT**<br>~~Ce~~|<0.75mA / 277VAC<br>~~Ce~~|||| ||**NO LOAD**<br>**POWER CONSUMPTION**|No load power consumption <0.5W|||| ||**OVER CURRENT**|95 ~ 108%<br>Constant current limiting, recovers automatically after fault condition is removed<br>Cn|||| ||**SHORT CIRCUIT**<br>~~a~~<br>~~Ce~~|Hiccup mode,recovers automatically after fault condition is removed<br>~~Ce~~|||| ||**OVER VOLTAGE**<br>~~a~~<br>~~Ce~~|Shut down output voltage, re-power on to recover<br>13.5 ~ 18V<br>27 ~ 34V<br>~~Ce~~<br>~~|~~|||| ||**INPUT OVER VOLTAGE Note.7**<br>Re|320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage)<br>can survive input voltage stress of 440Vac for 48 hours<br>~~Cn~~<br>~~|~~|||| ||**OVER TEMPERATURE**<br>Re<br>es|Shut down O/P voltage, recovers automatically after temperature goes down<br>~~|~~|||| ||**WORKING TEMP.**<br>Re<br>es<br>RR|Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>~~|~~|||| ||**MAX. CASE TEMP.**<br>es<br>RR<br>a|Tcase=+90℃|||| ||**WORKING HUMIDITY**<br>RR<br>a<br>RR|20 ~ 95% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**<br>a<br>RR|-40 ~ +<br>, 10 ~ 95% RH<br>90℃|||| ||**TEMP. COEFFICIENT**<br>RR<br>a<br>Rs|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)|||| ||**VIBRATION**<br>a<br>Rs|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS**<br>Rs|UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; IP67 approved|||| ||**WITHSTAND VOLTAGE**<br>~~Ce~~|I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC<br>~~Ce~~|||| ||**ISOLATION RESISTANCE**<br>~~Ce~~<br>~~ee~~|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>~~Ce~~<br>~~ee~~|||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>~~se~~<br>as|**Parameter**<br>~~eG~~|**Standard**<br>~~eG~~||**Test Level / Note**<br>~~eG~~| |||Conducted<br>a|EN55015(CISPR15)||-----| |||Radiated<br>~~RO~~|EN55015(CISPR15)<br>~~RO~~||-----<br>~~RO~~| |||Harmonic Current<br>a|EN61000-3-2<br>~~O~~||Class C @load≥50%<br>~~O~~| |||Voltage Flicker<br>~~RG~~|EN61000-3-3<br>~~RG~~||-----<br>~~RG~~| |||EN55024 , EN61204-3, EN61000-6-2<br>~~Cn~~|||| |||**Parameter**<br>~~Ge~~|**Standard**<br>~~Ge~~||**Test Level / Note**<br>~~Ge~~| |||ESD<br>~~eG~~|EN61000-4-2<br>~~eG~~||Level 3, 8KV air ; Level 2, 4KV contact<br>~~eG~~| |||Radiated<br>~~Ge~~<br>~~es~~|EN61000-4-3<br>~~Ge~~<br>~~es~~||Level 3<br>~~Ge~~<br>~~es~~| |||EFT / Burst<br>~~es~~|EN61000-4-4<br>~~es~~||Level 3<br>~~es~~| |||Surge<br>a|EN61000-4-5||4KV/Line-Line 6KV/Line-Earth| |||Conducted<br>a<br>a|EN61000-4-6||Level 3| |||Magnetic Field<br>a<br>a|EN61000-4-8<br>~~GC~~||Level 4<br>~~GC~~| |||Voltage Dips and Interruptions|EN61000-4-11||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| |||830.77K hrs min.<br>Telcordia SR-332(Bellcore) ; 219.75K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~se~~|||| ||**DIMENSION**<br>as|219 63<br>*<br>*35.5mm (L*W*H)|||| ||**PACKING**<br>1Kg;16pcs / 16Kg / 0.77CUFT<br>℃<br>℃<br>℃<br>℃<br>as<br>~~De~~<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7.Only for XLG-240<br>| series<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. This series meetsthe typical life expectancy of>50,000 hours of operation when Tcase, particularly© point (orTMP, per DLC), is about 70 _ or less.<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/(www.meanwell.com<br>11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to<br>the mains.<br>12. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft)<br>13.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>14.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~httos:/Avww.meanwell.com/Upload/PDF/LED_EN.padf~~||||| _File Name:XLG-240-SPEC 2019-03-13_ **XLG - 240 series** 240W Constant Power Mode LED Driver ## **SPECIFICATION** |**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**FULL POWER CURRENT RANGE**<br>**OUTPUT**<br>**CURRENT ADJ. RANGE**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>47 ~ 63Hz<br>2.7A / 115VAC 1.3A / 230VAC 1.1A / 277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH non-condensing<br>℃<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>830.77K hrs min.<br>Telcordia SR-332(Bellcore) ; 219.75K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>93%<br>92.5%<br>91%<br>COLD START 75A(t<br>=500 s measured at 50% I<br>) at 230VAC;<br>width<br>peak<br>μ<br>Per NEMA 410<br>**TOTAL HARMONIC DISTORTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**CONSTANT CURRENT REGION Note.2**<br>**PACKING**<br>**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>3 unit(circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC<br>Hiccup mode, recovers automatically after fault condition is removed<br>(Please refer to "STATIC CHARACTERISTIC" and “ DRIVING METHODS OF LED MODULE"section)<br>100 ~ 305VAC 142VDC ~ 431VDC<br>**OPEN CIRCUIT VOLTAGE (max.)**<br>380 ~ 440V<br>190~ 240V<br>61 ~ 78V<br>Shut down output voltage, re-power on to recovery<br>**TEMP. COEFFICIENT**<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>**WORKING TEMP.**<br>Tcase=-40 ~ +90<br>(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>PF<br>0.97 / 115VAC, PF<br>0.95 / 230VAC<br>full load<br>≧<br>≧<br>≧<br>, PF<br>0.92 / 277VAC at<br>(Please refer to "<br>"<br>)<br>Power Factor Characteristic section<br>THD< 10% (@ load<br>50% at 115VAC/230VAC ,@load<br>75% at 277VAC)<br>≧<br>≧<br>Please refer to “TOTAL HARMONIC DISTORTION (THD)” section<br>**CURRENT RIPPLE**<br>5.0%(@ Load<br>50<br>≥<br>% rated voltage)<br>**CURRENT TOLERANCE**<br>±4%<br>**SET UP TIME**<br>500ms/230VAC, 1200ms/115VAC<br>**STANDBY**<br>**POWER CONSUMPTION**<br>UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; IP67 approved<br>219 63<br>*<br>*35.5mm (L*W*H)<br>**LIFETIME**<br>**Note.4** 50000 hrs min.<br>350~1050mA<br>700mA<br>239.4W<br>700~1050mA<br>178~ 342V<br>370V<br>**XLG-240-L-**<br>239.4W<br>1400mA<br>90 ~171V<br>186V<br>700~2100mA<br>1400~2100mA<br>**XLG-240-M-**<br>239.6W<br>4280mA<br>27 ~ 56V<br>60V<br>2200~6660mA<br>4280~6660mA<br>**XLG-240-H-**<br>Standby power consumption <0.5W for AB-Type(Dimming OFF)<br>**INPUT OVER VOLTAGE Note.7** 320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage)<br>can survive input voltage stress of 440Vac for 48 hours<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>Adjustable for A/AB-Type only (via the built-in potentiometer)<br>1Kg;16pcs / 16Kg / 0.77CUFT<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2<br>**Standard**<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>4KV/Line-Line 6KV/Line-Earth<br>**NOTE**<br>℃<br>℃<br>℃<br>℃<br>EN55015(CISPR15)<br>EN55015(CISPR15)<br>EN61000-3-2<br>EN61000-3-3<br>-----<br>-----<br>Class C @load≥50%<br>-----<br>as~~a~~<br>~~se~~<br>~~Rs~~<br>~~RC~~<br>asa<br>a<br>as<br>Rs<br>as<br>es<br>es<br>Rs<br>~~Ge~~<br>a Pe<br>LC<br>i ee<br>~~CO~~<br>~~esP|~~<br>~~Ct~~<br>Rs<br>Rs<br>es<br>~~Ce~~<br>~~Ge~~<br>Rs<br>a<br>a ~~|~~<br>~~eG~~<br>~~sO~~<br>~~a~~<br>~~Pf~~<br>~~Re~~<br>Rs<br>~~a~~<br>~~as~~<br>~~PO~~<br>~~eG~~<br>~~a~~<br>~~G~~<br>a~~Ge~~<br>a<br>a<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turing ON/OFF the driver may lead to increase of the set up time.<br>7.Only for XLG-240<br>| series<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9.This series meets the typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly (tc)point (orTMP, per DLC), is about70<br>or less.<br>10. Please refer to the warranty statement on MEAN WELL's website at htto:/Awww.meanwell.com<br>11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to<br>the mains.<br>12. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500?t)<br>13.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>14.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~_https:/www.meanwell.com/Upload/PDF/LED_EN.pdf_~~<br>15. When the current adjustment is more than 110% of the rated current, it will be enter the Protection state.|**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**FULL POWER CURRENT RANGE**<br>**OUTPUT**<br>**CURRENT ADJ. RANGE**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>47 ~ 63Hz<br>2.7A / 115VAC 1.3A / 230VAC 1.1A / 277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +80<br>, 10 ~ 95% RH non-condensing<br>℃<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>830.77K hrs min.<br>Telcordia SR-332(Bellcore) ; 219.75K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>**ENVIRONMENT**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>93%<br>92.5%<br>91%<br>COLD START 75A(t<br>=500 s measured at 50% I<br>) at 230VAC;<br>width<br>peak<br>μ<br>Per NEMA 410<br>**TOTAL HARMONIC DISTORTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**CONSTANT CURRENT REGION Note.2**<br>**PACKING**<br>**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>3 unit(circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC<br>Hiccup mode, recovers automatically after fault condition is removed<br>(Please refer to "STATIC CHARACTERISTIC" and “ DRIVING METHODS OF LED MODULE"section)<br>100 ~ 305VAC 142VDC ~ 431VDC<br>**OPEN CIRCUIT VOLTAGE (max.)**<br>380 ~ 440V<br>190~ 240V<br>61 ~ 78V<br>Shut down output voltage, re-power on to recovery<br>**TEMP. COEFFICIENT**<br>±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>**WORKING TEMP.**<br>Tcase=-40 ~ +90<br>(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>℃<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>PF<br>0.97 / 115VAC, PF<br>0.95 / 230VAC<br>full load<br>≧<br>≧<br>≧<br>, PF<br>0.92 / 277VAC at<br>(Please refer to "<br>"<br>)<br>Power Factor Characteristic section<br>THD< 10% (@ load<br>50% at 115VAC/230VAC ,@load<br>75% at 277VAC)<br>≧<br>≧<br>Please refer to “TOTAL HARMONIC DISTORTION (THD)” section<br>**CURRENT RIPPLE**<br>5.0%(@ Load<br>50<br>≥<br>% rated voltage)<br>**CURRENT TOLERANCE**<br>±4%<br>**SET UP TIME**<br>500ms/230VAC, 1200ms/115VAC<br>**STANDBY**<br>**POWER CONSUMPTION**<br>UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; IP67 approved<br>219 63<br>*<br>*35.5mm (L*W*H)<br>**LIFETIME**<br>**Note.4** 50000 hrs min.<br>350~1050mA<br>700mA<br>239.4W<br>700~1050mA<br>178~ 342V<br>370V<br>**XLG-240-L-**<br>239.4W<br>1400mA<br>90 ~171V<br>186V<br>700~2100mA<br>1400~2100mA<br>**XLG-240-M-**<br>239.6W<br>4280mA<br>27 ~ 56V<br>60V<br>2200~6660mA<br>4280~6660mA<br>**XLG-240-H-**<br>Standby power consumption <0.5W for AB-Type(Dimming OFF)<br>**INPUT OVER VOLTAGE Note.7** 320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage)<br>can survive input voltage stress of 440Vac for 48 hours<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>Adjustable for A/AB-Type only (via the built-in potentiometer)<br>1Kg;16pcs / 16Kg / 0.77CUFT<br>**SAFETY &**<br>**EMC**<br>**(Note 8)**<br>**Parameter**<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN55024 , EN61204-3, EN61000-6-2<br>**Standard**<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level / Note**<br>**Test Level / Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>Level 3<br>Level 3<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>4KV/Line-Line 6KV/Line-Earth<br>**NOTE**<br>℃<br>℃<br>℃<br>℃<br>EN55015(CISPR15)<br>EN55015(CISPR15)<br>EN61000-3-2<br>EN61000-3-3<br>-----<br>-----<br>Class C @load≥50%<br>-----<br>as~~a~~<br>~~se~~<br>~~Rs~~<br>~~RC~~<br>asa<br>a<br>as<br>Rs<br>as<br>es<br>es<br>Rs<br>~~Ge~~<br>a Pe<br>LC<br>i ee<br>~~CO~~<br>~~esP|~~<br>~~Ct~~<br>Rs<br>Rs<br>es<br>~~Ce~~<br>~~Ge~~<br>Rs<br>a<br>a ~~|~~<br>~~eG~~<br>~~sO~~<br>~~a~~<br>~~Pf~~<br>~~Re~~<br>Rs<br>~~a~~<br>~~as~~<br>~~PO~~<br>~~eG~~<br>~~a~~<br>~~G~~<br>a~~Ge~~<br>a<br>a<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turing ON/OFF the driver may lead to increase of the set up time.<br>7.Only for XLG-240<br>| series<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9.This series meets the typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly (tc)point (orTMP, per DLC), is about70<br>or less.<br>10. Please refer to the warranty statement on MEAN WELL's website at htto:/Awww.meanwell.com<br>11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to<br>the mains.<br>12. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500?t)<br>13.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>14.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~_https:/www.meanwell.com/Upload/PDF/LED_EN.pdf_~~<br>15. When the current adjustment is more than 110% of the rated current, it will be enter the Protection state.|**XLG-240-L-**<br>~~a~~|**XLG-240-M-**|**XLG-240-M-**|**XLG-240-H-**|**XLG-240-H-**| |---|---|---|---|---|---|---| ||**RATED CURRENT**<br>as|700mA<br>~~a~~|1400mA||4280mA|| ||**RATED POWER**<br>as<br>~~se~~|239.4W<br>~~a~~<br>~~se~~|239.4W<br>~~se~~||239.6W<br>~~se~~|| ||**CONSTANT CURRENT REGION Note.2**<br>~~se~~<br>~~Rs~~|178~ 342V<br>~~se~~<br>~~Rs~~|90 ~171V<br>~~se~~<br>~~Rs~~||27 ~ 56V<br>~~se~~<br>~~Rs~~|| ||**FULL POWER CURRENT RANGE**<br>~~Rs~~<br>~~RC~~<br>as|700~1050mA<br>~~Rs~~<br>~~RC~~<br>|1400~2100mA<br>~~Rs~~<br>~~RC~~||4280~6660mA<br>~~Rs~~<br>~~RC~~|| ||**OPEN CIRCUIT VOLTAGE (max.)**<br>~~RC~~<br>as|370V<br>~~RC~~<br>|186V<br>~~RC~~||60V<br>~~RC~~|| ||**CURRENT ADJ. RANGE**<br>asa|350~1050mA<br>700~2100mA<br>2200~6660mA<br>Adjustable for A/AB-Type only (via the built-in potentiometer)<br>a||||| ||**CURRENT RIPPLE**<br>a<br>a<br>as|5.0%(@ Load<br>50<br>≥<br>% rated voltage)<br>a||||| ||**CURRENT TOLERANCE**<br>a<br>as<br>Rs|±4%||||| ||**SET UP TIME**<br>as<br>Rs|500ms/230VAC, 1200ms/115VAC||||| ||**VOLTAGE RANGE**<br>**Note.5**<br>Rs<br>as|(Please refer to "STATIC CHARACTERISTIC" and “ DRIVING METHODS OF LED MODULE"section)<br>100 ~ 305VAC 142VDC ~ 431VDC||||| ||**FREQUENCY RANGE**<br>as|47 ~ 63Hz||||| ||**POWER FACTOR (Typ.)**<br>as|PF<br>0.97 / 115VAC, PF<br>0.95 / 230VAC<br>full load<br>≧<br>≧<br>≧<br>, PF<br>0.92 / 277VAC at<br>(Please refer to "<br>"<br>)<br>Power Factor Characteristic section||||| ||**TOTAL HARMONIC DISTORTION**<br>es|THD< 10% (@ load<br>50% at 115VAC/230VAC ,@load<br>75% at 277VAC)<br>≧<br>≧<br>Please refer to “TOTAL HARMONIC DISTORTION (THD)” section||||| ||**EFFICIENCY (Typ.)**<br>es<br>es|93%|92.5%||91%|| ||**AC CURRENT (Typ.)**<br>es<br>es<br>Rs|2.7A / 115VAC 1.3A / 230VAC 1.1A / 277VAC||||| ||**INRUSH CURRENT(Typ.)**<br>es<br>Rs|COLD START 75A(t<br>=500 s measured at 50% I<br>) at 230VAC;<br>width<br>peak<br>μ<br>Per NEMA 410||||| ||**MAX. NO. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>Rs|3 unit(circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC||||| ||**LEAKAGE CURRENT**<br>~~Ge~~|<0.75mA / 277VAC<br>~~Ge~~||||| ||**STANDBY**<br>**POWER CONSUMPTION**|Standby power consumption <0.5W for AB-Type(Dimming OFF)||||| ||**SHORT CIRCUIT**<br>a|Hiccup mode, recovers automatically after fault condition is removed<br>||||| ||**OVER VOLTAGE**<br>a Pe<br>LC<br>i|380 ~ 440V<br>190~ 240V<br>61 ~ 78V<br>Shut down output voltage, re-power on to recovery<br>Pe<br>LC<br>||||| ||**INPUT OVER VOLTAGE Note.7** <br>LC<br>iee<br>~~CO~~<br>~~es~~|320 ~ 370VAC (Shut down output voltage when the input voltage exceeds protection voltage)<br>can survive input voltage stress of 440Vac for 48 hours<br>LC<br>ee<br>~~CO~~<br>||||| ||**OVER TEMPERATURE**<br>LC<br>i ee<br>~~CO~~<br>~~esP|~~|can survive input voltage stress of 440Vac for 48 hours<br>Shut down O/P voltage, recovers automatically after temperature goes down<br>LC<br>ee<br>~~CO~~<br>~~P|~~||||| ||**WORKING TEMP.**<br>~~CO~~<br>~~es~~<br>~~Ct~~<br>Rs|Tcase=-40 ~ +90<br>(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)<br>℃<br>~~CO~~<br><br>~~Ct~~||||| ||**MAX. CASE TEMP.**<br>~~Ct~~<br>Rs<br>Rs|Tcase=+90℃<br>~~Ct~~||||| ||**WORKING HUMIDITY**<br>Rs<br>Rs<br>es|20 ~ 95% RH non-condensing||||| ||**STORAGE TEMP., HUMIDITY**<br>Rs<br>es|-40 ~ +80<br>, 10 ~ 95% RH non-condensing<br>℃||||| ||**TEMP. COEFFICIENT**<br>es<br>~~Ce~~|±<br>℃<br>℃<br>0.03%/<br>(0 ~ 60<br>)<br>~~Ce~~||||| ||**VIBRATION**<br>~~Ce~~<br>~~Ge~~|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>~~Ce~~<br>~~Ge~~||||| ||**SAFETY STANDARDS**<br>Rs|UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; IP67 approved||||| ||**WITHSTAND VOLTAGE**<br>Rs|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC||||| ||**ISOLATION RESISTANCE**<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Rs<br>a<br>a<br>~~eG~~<br>~~sO~~<br>~~a~~<br>~~Pf~~<br>~~Re~~<br>Rs<br>~~a~~<br>~~as~~<br>~~PO~~<br>~~eG~~<br>~~a~~|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃||||| |||**Parameter**<br>a||**Standard**<br> ~~|~~||**Test Level / Note**<br>~~|~~| |||Conducted<br>~~eG~~||EN55015(CISPR15)<br>~~eG~~||-----<br>~~eG~~| |||Radiated<br>~~eG~~<br>~~sO~~||EN55015(CISPR15)<br>~~eG~~<br>~~sO~~||-----<br>~~eG~~<br>~~sO~~| |||Harmonic Current<br>~~sO~~<br>~~a~~||EN61000-3-2<br>~~sO~~<br>~~a~~||Class C @load≥50%<br>~~sO~~<br>~~a~~| |||Voltage Flicker<br>~~a~~<br>~~Pf~~||EN61000-3-3<br>~~a~~<br>~~Pf~~||-----<br>~~a~~<br>~~Pf~~| |||EN55024 , EN61204-3, EN61000-6-2<br>~~Pf~~<br>~~Re~~<br>Rs||||| |||**Parameter**<br>~~Re~~<br>Rs||**Standard**<br>~~Re~~||**Test Level / Note**<br>~~Re~~| |||ESD<br>Rs<br>~~a~~||EN61000-4-2<br>~~a~~||Level 3, 8KV air ; Level 2, 4KV contact<br>~~a~~| |||Radiated<br>~~as~~||EN61000-4-3<br>~~as~~||Level 3<br>~~as~~| |||EFT / Burst<br>~~PO~~||EN61000-4-4<br>~~PO~~||Level 3<br>~~PO~~| |||Surge<br>~~eG~~||EN61000-4-5<br>~~eG~~||4KV/Line-Line 6KV/Line-Earth<br>~~eG~~| |||Conducted<br>~~eG~~<br>~~a~~||EN61000-4-6<br>~~eG~~||Level 3<br>~~eG~~<br>~~G~~| |||Magnetic Field||EN61000-4-8||Level 4| |||Voltage Dips and Interruptions||EN61000-4-11||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| ||**MTBF**<br>a~~Ge~~|830.77K hrs min.<br>Telcordia SR-332(Bellcore) ; 219.75K hrs min. MIL-HDBK-217F (25<br>)<br>℃<br>~~Ge~~||||| ||**LIFETIME**<br>**Note.4** <br>~~Ge~~|50000 hrs min.<br>~~Ge~~||||| ||**DIMENSION**<br>a|219 63<br>*<br>*35.5mm (L*W*H)||||| ||**PACKING**<br>1Kg;16pcs / 16Kg / 0.77CUFT<br>℃<br>℃<br>℃<br>℃<br>a<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turing ON/OFF the driver may lead to increase of the set up time.<br>7.Only for XLG-240<br>| series<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9.This series meets the typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly (tc)point (orTMP, per DLC), is about70<br>or less.<br>10. Please refer to the warranty statement on MEAN WELL's website at htto:/Awww.meanwell.com<br>11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to<br>the mains.<br>12. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500?t)<br>13.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>14.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>~~_https:/www.meanwell.com/Upload/PDF/LED_EN.pdf_~~<br>15. When the current adjustment is more than 110% of the rated current, it will be enter the Protection state.|||||| _File Name:XLG-240-SPEC 2019-03-13_ **XLG - 240 series** ## 240W Constant Power Mode LED Driver ## **BLOCK DIAGRAM** **==> picture [476 x 138] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.C.P. DIM+<br>DIM-<br>(AB Type)<br>FG O.L.P. DETECTION<br>PFC PWM CIRCUIT<br>CONTROL CONTROL<br>O.T.P.<br>O.V.P.<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** ※ -IV Operating Area ## ◎ **XLG-240-L** ## ◎ **XLG-240-M** **==> picture [472 x 162] intentionally omitted <==** **----- Start of picture text -----**<br> 350V 350mA, 342V 175.0V 700mA, 171.0V<br>340V<br>330V 56mA, 342V 700mA, 342V 165.0V 112mA, 171.0V 1400mA, 171.0V<br>320V<br>310V 155.0V<br>300V<br>290V 145.0V<br>280V<br>270V 135.0V<br>260V<br>250V 125.0V<br>240V 2100mA, 114.0V<br>230V 1050mA, 228V 115.0V<br>220V<br>210V 105.0V<br>200V<br>190V 56mA, 178V 700mA, 178V 95.0V 112mA, 90.0V 1400mA, 90.0V<br>180V 1050mA, 178V 2100mA, 90.0V<br>170V 85.0V<br>0mA 100mA 200mA 300mA 400mA 500mA 600mA 700mA 800mA 900mA 1000mA1100mA1200mA 0mA 250mA 500mA 750mA 1000mA 1250mA 1500mA 1750mA 2000mA 2250mA<br>Recommend Performance Region Allow Operation Region Recommend Performance Region Allow Operation Region<br>**----- End of picture text -----**<br> ## ◎ **XLG-240-H** ## ◎ **XLG-240-12,24** - ※ This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs. **==> picture [478 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> 60V direct drive way) or Constant Voltage mode (usually through<br>2200mA, 56V<br>55V 4280mA, 56V additional DC/DC driver) to drive the LEDs.<br>352mA, 56V<br>50V<br>45V 100 In the constant current<br>(B) region, the highest voltage<br>40V35V 6660mA, 36V VoltageConstant(A) area Current areaConstant at the output of the driverdepends on the configuration<br>60 of the end systems.<br>30V (min.) Should there be any<br>(C) compatibility issues, please<br>25V 352mA, 27V 4400mA, 27V 6660mA, 27V ProtectionHiccup please contact MEAN WELL.<br>20V 50 100 Io(%)<br>0mA 1000mA 2000mA 3000mA 4000mA 5000mA 6000mA 7000mA<br>Typical output current normalized by rated current (%)<br>Recommend Performance Region Allow Operation Region<br>Vo(%)<br>**----- End of picture text -----**<br> _File Name:XLG-240-SPEC 2019-03-13_ **XLG - 240 series** 240W Constant Power Mode LED Driver ## **DIMMING OPERATION** **==> picture [453 x 54] intentionally omitted <==** **----- Start of picture text -----**<br> Vo+(Red)<br>AC/N(Blue) Vo-(Black)<br>AC/L(Brown) DIM-(White)<br>FG(Green/Yellow) DIM+(Blue)<br>**----- End of picture text -----**<br> - ※ **3 in 1 dimming function (for AB-Type)** - �Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance. - �Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers. �Dimming source current from power supply: 100μA (typ.) - Applying additive 0 ~ 10VDC **==> picture [450 x 486] intentionally omitted <==** **----- Start of picture text -----**<br> Applying additive 0 ~ 10VDC 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>◎ Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>◎ Applying additive resistance: 100%<br>90%<br>Vo+ + + 80%<br>70%<br>-<br>Vo- - 60%<br>DIM+ 50%<br>40%<br>Additive Resistance<br>30%<br>DIM- 20%<br>“DO NOT connect "DIM- to Vo-" 10%<br>0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.<br>2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> _File Name:XLG-240-SPEC 2019-03-13_ **XLG - 240 series** 240W Constant Power Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [491 x 395] intentionally omitted <==** **----- Start of picture text -----**<br> 230VAC<br>100 100<br>80 80<br>230VAC 230VAC<br>Input only 110VAC Input only<br>60 60<br>40 40<br>20 20<br>-40 -30 -10 0 15 30 40 50 60 (HORIZONTAL) -40 -30 0 10 30 50 70 90 (HORIZONTAL)<br>AMBIENT TEMPERATURE,Ta ( ℃ ) Tcase ( ℃ )<br>If XLG-240 operates in Constant Power mode<br>with the rated current the maximum workable<br>Ta is 50℃ (Typ. 230VAC) or 40℃ (Typ. 110VAC)<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>Constant Current Mode<br>100<br>1<br>90<br>0.98<br>80 0.96<br>70 0.94<br>0.92 277V(300W)<br>60<br>0.9 230V(300W)<br>50 0.88 115V(256W)<br>40 0.86<br>0.84<br>(300W)<br>100 110 140 160 180 200 220 240 260 280 305 50% 60% 70% 80% 90% 100%<br>INPUT VOLTAGE (V) 60Hz LOAD<br>LOAD (%) LOAD (%)<br>LOAD (%)<br>PF<br>**----- End of picture text -----**<br> ## **TOTAL HARMONIC DISTORTION (THD)** **==> picture [114 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> ※ XLG-240-L Model, Tcase at 75℃<br>**----- End of picture text -----**<br> **==> picture [243 x 125] intentionally omitted <==** **----- Start of picture text -----**<br> 10%<br>9%<br>8%<br>7%<br>6% 277V(300W)<br>5% 230V(300W)<br>4% 115V(256W)<br>3%<br>2%<br>1%<br>0%<br>50% 60% 70% 80% 90% 100%<br>LOAD<br>THD<br>**----- End of picture text -----**<br> **EFFICIENCY vs LOAD** XLG-240 series possess superior working efficiency that up to 93.5% can be reached in field applications. **==> picture [235 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> ※ XLG-240-L Model, Tcase at 75℃<br>96<br>92<br>88<br>84<br>277V(300W)<br>80<br>230V(300W)<br>76<br>115V(256W)<br>72<br>68<br>64<br>60<br>10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>LOAD<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> _File Name:XLG-240-SPEC 2019-03-13_ **XLG - 240 series** 240W Constant Power Mode LED Driver ## **LIFE** TIME **==> picture [409 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>Life tim e<br>40<br>20<br>0<br>20 30 40 50 60 70 80 90<br>Tcase (℃ )<br>(Kh)<br>LIFETIME<br>**----- End of picture text -----**<br> _File Name:XLG-240-SPEC 2019-03-13_ **XLG - 240 series** ## 240W Constant Power Mode LED Driver **==> picture [492 x 577] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.:237 Unit:mm<br>※ A-Type<br>219<br>208<br>300±20 195 300±20<br>AC/N(Blue) Vo+(Red)<br>AC/L(Brown)FG(Green/Yellow) SJOW 17AWGx2C tc 105 SJOW 17AWGx2C&05RN-F 1.0mm2 for H&M typeVo-(Black)<br>&H05RN-F 1.0mm2 (SJOW 14AWGx2C for 12/24V type)(SOOW 17AWGx2C&H07RN-F 1.0mm2 for L type)<br>4-ψ4.5<br>�tc : Max. Case Temperature<br>37.8<br>※ AB-Type<br>219<br>208<br>300±20 195 300±20<br>SJOW 17AWGx2C&05RN-F 1.0mm for H&M type(SOOW 17AWGx2C&H07RN-F 1.0mm2 2 for L type)<br>Vo+(Red)<br>AC/N(Blue) Vo-(Black)<br>AC/L(Brown) DIM-(White)<br>FG(Green/Yellow) tc 105 DIM+(Blue)<br>SJOW 17AWGx2C<br>&H05RN-F 1.0mm2 UL2517 20AWG*2C<br>4-ψ4.5 325±20<br>�tc : Max. Case Temperature<br>63 45.8<br>20<br>35 35.5<br>21.2<br>63 45.8<br>20<br>35 35.5<br>**----- End of picture text -----**<br> ## **INSTALLATION MANUAL** _File Name:XLG-240-SPEC 2019-03-13_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →