- Manufacturer: MEAN WELL
- Product type: AC / DC LED Power Supplies
- SVHC: No SVHC (25-Jun-2025)
- Product Range: XLG-150
- Output Current: 2.8A
- LED Driver Mode: Constant Current, Constant Voltage
- Output Power Max: 150W
- Input Voltage Max: 305V
- Input Voltage Min: 100V
- Output Voltage Max: 56VDC
- Power Supply Applications: LED Lighting
| Delivery and price | |
|---|---|
| Units per pack | 100 |
| Price | 31.81 € |
| Current stock | 10+ |
| Lead time | 30 days |
**XLG - 150 series** 150W Constant Power Mode LED Driver **==> picture [15 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>•<br>•<br>•<br>•<br>•<br>•<br>**----- End of picture text -----**<br> **==> picture [15 x 57] intentionally omitted <==** **----- Start of picture text -----**<br> •<br>•<br>■<br>**----- End of picture text -----**<br> **==> picture [13 x 11] intentionally omitted <==** **----- Start of picture text -----**<br> ■<br>**----- End of picture text -----**<br> **==> picture [279 x 169] intentionally omitted <==** **----- Start of picture text -----**<br> IS 15885(Part 2/Sec13)<br>THOMAS SAMUEL THOMAS SAMUEL 05<br>R-41027766 © Gy cAks Abn CB HICE Note.12<br>(for XLG-150I type only )<br>■ Applications<br>• Skyscraper lighting<br>mode operation • Street lighting<br>• Floodlight Lighting<br>• Stage lighting<br>design) • Fishing lighting<br>Protection can • Horticulture lighting<br>• Bay lighting<br>• DMX power supply<br>•<br>**----- End of picture text -----**<br> **==> picture [505 x 202] intentionally omitted <==** **----- Start of picture text -----**<br> -40 ℃ ~+90 ℃ case temperature under free air convection. The design of metal housing and IP67 ingress<br>protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative<br>environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application<br>-<br>environments in almost any spots that may install LED luminaires in the world. XLG 150 series comply<br>with the latest version of IEC61347 / GB7000 2015 and UL8750 international safety regulations .<br>The output and dimming circuit are also completely in accordance with the new regulations with<br>isolation to ensure the safety of both user and luminaire system during installation .<br>Model Encoding<br>XLG - 150[1]-[L]-[|<br>|<br>Function options<br>Rated output voltage(12/24V or L/M/H types)<br>I: for India version(by request with Input over voltage protection)<br>{ [_] : For standard version<br>**----- End of picture text -----**<br> _File Name:XLG-150-SPEC 2019-07-05_ 150W Constant Voltage + Constant Current LED Driver **XLG - 150 series** ## **SPECIFICATION** |**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>500ms, 100ms/230VAC, 1200ms, 100ms/115VAC<br>10ms/ 230VAC 10ms/ 115VAC<br>47 ~ 63Hz<br>1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>90℃<br>±<br>℃<br>℃<br>0.06%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Hiccup mode, recovers automatically after fault condition is removed<br>Shut down output voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.6**<br>**HOLD UP TIME (Typ.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>**CONSTANT CURRENT REGION Note.2**<br>**OVER CURRENT**<br>COLD START 50A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>500μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC<br>℃<br>℃<br>℃<br>℃<br>fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.<br>95 ~ 108%<br>Hiccup mode<br>constant current limiting,<br>or<br>recovers automatically after fault condition is removed<br>Hiccup mode orconstant current limiting, recovers automatically after fault condition is removed<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**XLG-150 -12-**<br>12V<br>12.5A<br>150mVp-p<br>8.4~ 12V<br>150W<br>±3.0%<br>±0.5%<br>±2%<br>91.5%<br>13.5 ~ 18V<br>712.17K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>213.3Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>180 63<br>*<br>*35.5mm (L*W*H)<br>0.8Kg;16pcs / 13.4Kg /0.67CUFT<br>**SAFETY STANDARDS**<br>**Note.7** UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), UL879,CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; EAC TP TC 004;IS15885(Part2/Sec13)(for XLG-150I type only);IP67 approved<br>**XLG-150 -24-**<br>24V<br>6.25A<br>240mVp-p<br>16.8~ 24V<br>150W<br>±2.0%<br>±0.5%<br>±1%<br>93%<br>27 ~ 34V<br>**NO LOAD**<br>**POWER CONSUMPTION**<br>**INPUT OVER VOLTAGE Note.7** 320 ~ 390<br>(Shut down output voltage when the input voltage exceeds protection voltage,<br>)<br>VAC<br>recovers automatically after fault condition is removed<br>can survive input voltage stress of 440Vac for 48 hours<br>No load power consumption <0.5W for A-Type<br>**CURRENT ADJ. RANGE**<br>6.5~ 12.5A<br>3.2~ 6.25A<br>Adjustable for A-Type only (via the built-in potentiometer)<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN61547<br>**Parameter**<br>ESD<br>Radiated<br>EFT/Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>**Standard**<br>EN61000-3-3<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level/Note**<br>-----<br>-----<br>Class C @load≥50%<br>-----<br>**Test Level/Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 2<br>Level 3<br>4KV/Line-Line 6KV/Line-Earth(6K/10K option)<br>Level 2<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55015(CISPR15) ,GB/T17743<br>EN55015(CISPR15) ,GB/T17743<br>EN61000-3-2 ,GB/T17625.1<br>~~a~~<br>Ge<br>~~a~~<br>~~G~~<br>a<br>a<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7.Input over voltage only for XLG-150<br>| series ,and<br>| series without UL/CSA certificate.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9.The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/Avww.meanwell.com<br>11. This series meets the typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly(©)point (orTMP, per DLC), isabout75<br>or less.<br>12.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>14. To|**MODEL**<br>**OUTPUT**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER TEMPERATURE**<br>**OVER VOLTAGE**<br>500ms, 100ms/230VAC, 1200ms, 100ms/115VAC<br>10ms/ 230VAC 10ms/ 115VAC<br>47 ~ 63Hz<br>1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC<br><0.75mA / 277VAC<br>20 ~ 95% RH non-condensing<br>-40 ~ +<br>, 10 ~ 95% RH<br>90℃<br>±<br>℃<br>℃<br>0.06%/<br>(0 ~ 60<br>)<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**PROTECTION**<br>Hiccup mode, recovers automatically after fault condition is removed<br>Shut down output voltage, re-power on to recover<br>**SHORT CIRCUIT**<br>I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC<br>I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**TOTAL HARMONIC DISTORTION**<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**RATED POWER**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**Note.6**<br>**HOLD UP TIME (Typ.)**<br>**RIPPLE & NOISE (max.) Note.3**<br>**VOLTAGE TOLERANCE Note.4**<br>**CONSTANT CURRENT REGION Note.2**<br>**OVER CURRENT**<br>COLD START 50A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>500μ<br>;Per NEMA 410<br>**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**<br>4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC<br>**MAX. CASE TEMP.**<br>Tcase=+90℃<br>(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC<br>℃<br>℃<br>℃<br>℃<br>fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.<br>95 ~ 108%<br>Hiccup mode<br>constant current limiting,<br>or<br>recovers automatically after fault condition is removed<br>Hiccup mode orconstant current limiting, recovers automatically after fault condition is removed<br>PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧<br>THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧<br>Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃<br>**XLG-150 -12-**<br>12V<br>12.5A<br>150mVp-p<br>8.4~ 12V<br>150W<br>±3.0%<br>±0.5%<br>±2%<br>91.5%<br>13.5 ~ 18V<br>712.17K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>213.3Khrs min. MIL-HDBK-217F (25<br>)<br>℃<br>180 63<br>*<br>*35.5mm (L*W*H)<br>0.8Kg;16pcs / 13.4Kg /0.67CUFT<br>**SAFETY STANDARDS**<br>**Note.7** UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), UL879,CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; EAC TP TC 004;IS15885(Part2/Sec13)(for XLG-150I type only);IP67 approved<br>**XLG-150 -24-**<br>24V<br>6.25A<br>240mVp-p<br>16.8~ 24V<br>150W<br>±2.0%<br>±0.5%<br>±1%<br>93%<br>27 ~ 34V<br>**NO LOAD**<br>**POWER CONSUMPTION**<br>**INPUT OVER VOLTAGE Note.7** 320 ~ 390<br>(Shut down output voltage when the input voltage exceeds protection voltage,<br>)<br>VAC<br>recovers automatically after fault condition is removed<br>can survive input voltage stress of 440Vac for 48 hours<br>No load power consumption <0.5W for A-Type<br>**CURRENT ADJ. RANGE**<br>6.5~ 12.5A<br>3.2~ 6.25A<br>Adjustable for A-Type only (via the built-in potentiometer)<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>EN61547<br>**Parameter**<br>ESD<br>Radiated<br>EFT/Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>**Standard**<br>EN61000-3-3<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level/Note**<br>-----<br>-----<br>Class C @load≥50%<br>-----<br>**Test Level/Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 2<br>Level 3<br>4KV/Line-Line 6KV/Line-Earth(6K/10K option)<br>Level 2<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>EN55015(CISPR15) ,GB/T17743<br>EN55015(CISPR15) ,GB/T17743<br>EN61000-3-2 ,GB/T17625.1<br>~~a~~<br>Ge<br>~~a~~<br>~~G~~<br>a<br>a<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7.Input over voltage only for XLG-150<br>| series ,and<br>| series without UL/CSA certificate.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9.The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/Avww.meanwell.com<br>11. This series meets the typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly(©)point (orTMP, per DLC), isabout75<br>or less.<br>12.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>14. To|**XLG-150 -12-**|**XLG-150 -12-**|**XLG-150 -24-**|**XLG-150 -24-**| |---|---|---|---|---|---| ||**DC VOLTAGE**|12V||24V|| ||**CONSTANT CURRENT REGION Note.2**|8.4~ 12V||16.8~ 24V|| ||**RATED CURRENT**|12.5A||6.25A|| ||**RATED POWER**|150W||150W|| ||**RIPPLE & NOISE (max.) Note.3**|150mVp-p||240mVp-p|| ||**CURRENT ADJ. RANGE**|6.5~ 12.5A<br>3.2~ 6.25A<br>Adjustable for A-Type only (via the built-in potentiometer)|||| ||**VOLTAGE TOLERANCE Note.4**|±3.0%||±2.0%|| ||**LINE REGULATION**|±0.5%||±0.5%|| ||**LOAD REGULATION**|±2%||±1%|| ||**SETUP, RISE TIME**<br>**Note.6**|500ms, 100ms/230VAC, 1200ms, 100ms/115VAC|||| ||**HOLD UP TIME (Typ.)**|10ms/ 230VAC 10ms/ 115VAC|||| ||**VOLTAGE RANGE**<br>**Note.5**|(Please refer to "STATIC CHARACTERISTIC" section)<br>100 ~ 305VAC 142 ~ 431VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**POWER FACTOR**|PF<br>0.97/115VAC, PF<br>0.95/230VAC, PF<br>0.92/277VAC@full load<br>≧<br>≧<br>≧|||| ||**TOTAL HARMONIC DISTORTION**|THD< 10%(@load 50%/115VC,230VAC; @load 75%/277VAC)<br>≧<br>≧|||| ||**EFFICIENCY (Typ.)**|91.5%||93%|| ||**AC CURRENT**|1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC|||| ||**INRUSH CURRENT(Typ.)**|COLD START 50A(twidth=<br>s measured at 50% Ipeak) at 230VAC<br>500μ<br>;Per NEMA 410|||| ||**MAX. No. of PSUs on 16A**<br>**CIRCUIT BREAKER**|4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC|||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC|||| ||**NO LOAD**<br>**POWER CONSUMPTION**|No load power consumption <0.5W for A-Type|||| ||**OVER CURRENT**|95 ~ 108%<br>Hiccup mode orconstant current limiting, recovers automatically after fault condition is removed|||| ||**SHORT CIRCUIT**|Hiccup mode<br>constant current limiting,<br>or<br>recovers automatically after fault condition is removed|||| ||**OVER VOLTAGE**|Shut down output voltage, re-power on to recover<br>13.5 ~ 18V<br>27 ~ 34V|||| ||**INPUT OVER VOLTAGE Note.7**|320 ~ 390<br>(Shut down output voltage when the input voltage exceeds protection voltage,<br>)<br>VAC<br>recovers automatically after fault condition is removed<br>can survive input voltage stress of 440Vac for 48 hours|||| ||**OVER TEMPERATURE**|Hiccup mode, recovers automatically after fault condition is removed|||| ||**WORKING TEMP.**|Tcase=-40 ~ +90<br>(Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)<br>℃|||| ||**MAX. CASE TEMP.**|Tcase=+90℃|||| ||**WORKING HUMIDITY**|20 ~ 95% RH non-condensing|||| ||**STORAGE TEMP., HUMIDITY**|-40 ~ +<br>, 10 ~ 95% RH<br>90℃|||| ||**TEMP. COEFFICIENT**|±<br>℃<br>℃<br>0.06%/<br>(0 ~ 60<br>)|||| ||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS**<br>**Note.7**|UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), UL879,CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; EAC TP TC 004;IS15885(Part2/Sec13)(for XLG-150I type only);IP67 approved|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC|||| ||**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25<br>/ 70% RH<br>℃|||| ||**MTBF**<br>**EMC IMMUNITY**<br>**EMC EMISSION**|**Parameter**|**Standard**||**Test Level/Note**| |||Conducted|EN55015(CISPR15) ,GB/T17743||-----| |||Radiated|EN55015(CISPR15) ,GB/T17743||-----| |||Harmonic Current|EN61000-3-2 ,GB/T17625.1||Class C @load≥50%| |||Voltage Flicker|EN61000-3-3||-----| |||EN61547|||| |||**Parameter**|**Standard**||**Test Level/Note**| |||ESD|EN61000-4-2||Level 3, 8KV air ; Level 2, 4KV contact| |||Radiated|EN61000-4-3||Level 2| |||EFT/Burst|EN61000-4-4||Level 3| |||Surge<br>~~a~~|EN61000-4-5<br>Ge||4KV/Line-Line 6KV/Line-Earth(6K/10K option)| |||Conducted<br>~~a~~<br>~~a~~|EN61000-4-6<br>Ge<br>~~G~~||Level 2| |||Magnetic Field<br>~~a~~<br>~~a~~|EN61000-4-8<br>Ge<br>~~G~~||Level 4| |||Voltage Dips and Interruptions<br>~~a~~|EN61000-4-11<br>~~G~~||>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods| |||712.17K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>213.3Khrs min. MIL-HDBK-217F (25<br>)<br>℃|||| ||**DIMENSION**<br>a|180 63<br>*<br>*35.5mm (L*W*H)|||| ||**PACKING**<br>℃<br>℃<br>℃<br>℃<br>fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.<br>0.8Kg;16pcs / 13.4Kg /0.67CUFT<br>a<br>1. All parameters NOT specially mentioned are measured at230VAC input, rated current and 25 _of ambienttemperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7.Input over voltage only for XLG-150<br>| series ,and<br>| series without UL/CSA certificate.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9.The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/Avww.meanwell.com<br>11. This series meets the typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly(©)point (orTMP, per DLC), isabout75<br>or less.<br>12.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13.For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>14. To||||| fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains. _File Name:XLG-150-SPEC 2019-07-05_ **XLG - 150 series** 150W Constant Power Mode LED Driver ## **SPECIFICATION** |**NOTE**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Parameter**<br>ESD<br>Radiated<br>EFT/Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>**Standard**<br>EN61000-3-3<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level/Note**<br>-----<br>-----<br>Class C @load≥50%<br>-----<br>**Test Level/Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>4KV/Line-Line 6KV/Line-Earth(6K/10K option)<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**FULL POWER CURRENT RANGE**<br>**OUTPUT**<br>**CURRENT ADJ RANGE**<br>**.**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS Note.7**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP HUMIDITY**<br>**.,**<br>**VIBRATION**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>**TOTAL HARMONIC DISTORTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CONSTANT CURRENT REGION**<br>**MAX NO**<br>**PSU**<br>**.**<br>**. of**<br>**s on 16A**<br>**CIRCUIT BREAKER**<br>**OPEN CIRCUIT VOLTAGE (max.)**<br>**TEMP. COEFFICIENT**<br>**WORKING TEMP.**<br>**MAX CASE TEMP**<br>**.**<br>**.**<br>**CURRENT RIPPLE**<br>**CURRENT TOLERANCE**<br>**SET UP TIME**<br>**STANDBY POWER**<br>**CONSUMPTION**<br>**Note.14**<br>**INPUT OVER VOLTAGE Note.7**<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>20 ~ 95%<br>non-condensing<br>RH<br>-40 ~ +80<br>, 10 ~ 95%<br>non-condensing<br>℃<br>RH<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>93%<br>92.5%<br>92%<br>COLD START<br>VAC<br>50A(twidth=500 s measured at 50% Ipeak) at 230<br>;<br>μ<br>Per<br>410<br>NEMA<br>I/P-O/P:3.75<br>I/P-<br>:2<br>O/P-<br>:1.5<br>KVAC<br>FG<br>KVAC<br>FG<br>KVAC<br>I/P-O/P, I/P-<br>, O/P-<br>:100M Ohms / 500<br>/ 25<br>/ 70%<br>FG<br>FG<br>VDC<br>RH<br>℃<br>4 unit(circuit breaker of type B) / 8 units(circuit breaker of type C) at 230VAC<br>Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed<br>(Please refer to "<br>" ang “<br>"section)<br>STATIC CHARACTERISTIC<br>DRIVING METHODS OF LED MODULE<br>100 ~ 305<br>142<br>~ 431<br>VAC<br>VDC<br>VDC<br>230 ~ 265V<br>128~ 150V<br>61 ~ 78V<br>Shut down output voltage, re-power on to recovery<br>±0.06%/<br>(0 ~ 60<br>)<br>℃<br>℃<br>Tcase=-40 ~ +90<br>(Please refer to "<br>vs<br>" section)<br>℃<br>OUTPUT LOAD<br>TEMPERATURE<br>Tcase=+90℃<br>0.97 / 115<br>,<br>0.95 / 230<br>full load<br>PF<br>VAC PF<br>VAC<br>≧<br>≧<br>≧<br>,<br>0.92 / 277<br>at<br>PF<br>VAC<br>(Please refer to "<br>"<br>)<br>Power Factor Characteristic section<br>THD<br>VAC<br>VAC<br>VAC<br>< 10% (@ load<br>50% at 115<br>/230<br>,@load<br>75% at 277<br>)<br>≧<br>≧<br>Please refer to “<br>(<br>)” section<br>TOTAL HARMONIC DISTORTION THD<br>3.0%(@ full load)<br>±5%<br>500ms/230<br>, 1200ms/115<br>VAC<br>VAC<br>UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; EAC TP TC 004;IS15885(Part2/Sec13)(for XLG-150I type only);IP67 approved<br>350~1050mA<br>700mA<br>150W<br>700~1050mA<br>120 ~214V<br>225V<br>**XLG-150 -L-**<br>150W<br>1400mA<br>60 ~ 107V<br>115V<br>700~2100mA<br>1400~2100mA<br>**XLG-150 -M-**<br>150W<br>2800mA<br>27 ~ 56V<br>60V<br>1400~4170mA<br>2680~4170mA<br>**XLG-150 -H-**<br>Hiccup mode, recovers automatically after fault condition is removed<br>Standby power consumption <0.5W for AB-Type(Dimming OFF)<br>can survive input voltage stress of 440Vac for 48 hours<br>1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC<br>Adjustable for A/AB-Type only (via the built-in potentiometer)<br>**EMC**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>712.17K hrs min.<br>Telcordia<br>-332 (Bellcore) ;<br>SR<br>213.3Khrs min.<br>-<br>-217F (25<br>)<br>MIL HDBK<br>℃<br>**PACKING**<br>0.8Kg;16pcs/13.4Kg/0.67CUFT<br>**LIFETIME**<br>**Note.4** 50000 hrs min.<br>180 63<br>*<br>*35.5mm (L*W*H)<br>℃<br>℃<br>℃<br>℃<br>fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected<br>to the mains.<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Level 2<br>Level 2<br>4.0%(@ full load)<br>3.0%(@ full load)<br>EN61547<br>EN55015(CISPR15) ,GB/T17743<br>EN55015(CISPR15) ,GB/T17743<br>EN61000-3-2 ,GB/T17625.1<br>320 ~ 390<br>(Shut down output voltage when the input voltage exceeds protection voltage,<br>)<br>VAC<br>recovers automatically after fault condition is removed<br>~~GG~~<br>~~eee~~<br>Ce~~a~~<br>~~Ce~~<br>a<br>1. All parameters NOTspecially mentioned are measured at230VAC input, rated currentand25 —_of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7. Input over voltage only for XLG-150<br>| series ,and<br>| series without UL/CSA certificate.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. The ambienttemperature derating of3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/Avww.meanwell.com<br>11. This series meetsthe typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly(t0) point (orTMP, per DLC), isabout75<br>or less.<br>12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>14. To|**NOTE**<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Parameter**<br>ESD<br>Radiated<br>EFT/Burst<br>Surge<br>Conducted<br>Magnetic Field<br>Voltage Dips and Interruptions<br>**Standard**<br>EN61000-3-3<br>**Standard**<br>EN61000-4-2<br>EN61000-4-3<br>EN61000-4-4<br>EN61000-4-5<br>EN61000-4-6<br>EN61000-4-8<br>EN61000-4-11<br>**Test Level/Note**<br>-----<br>-----<br>Class C @load≥50%<br>-----<br>**Test Level/Note**<br>Level 3, 8KV air ; Level 2, 4KV contact<br>Level 3<br>4KV/Line-Line 6KV/Line-Earth(6K/10K option)<br>Level 4<br>>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods<br>**MODEL**<br>**RATED CURRENT**<br>**RATED POWER**<br>**FULL POWER CURRENT RANGE**<br>**OUTPUT**<br>**CURRENT ADJ RANGE**<br>**.**<br>**VOLTAGE RANGE**<br>**Note.5**<br>**FREQUENCY RANGE**<br>**POWER FACTOR (Typ.)**<br>**EFFICIENCY (Typ.)**<br>**AC CURRENT (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT(Typ.)**<br>**LEAKAGE CURRENT**<br>**SAFETY STANDARDS Note.7**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP HUMIDITY**<br>**.,**<br>**VIBRATION**<br>**OVER VOLTAGE**<br>**OVER TEMPERATURE**<br>**ENVIRONMENT**<br>**SAFETY &**<br>**PROTECTION**<br>**SHORT CIRCUIT**<br>**TOTAL HARMONIC DISTORTION**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**CONSTANT CURRENT REGION**<br>**MAX NO**<br>**PSU**<br>**.**<br>**. of**<br>**s on 16A**<br>**CIRCUIT BREAKER**<br>**OPEN CIRCUIT VOLTAGE (max.)**<br>**TEMP. COEFFICIENT**<br>**WORKING TEMP.**<br>**MAX CASE TEMP**<br>**.**<br>**.**<br>**CURRENT RIPPLE**<br>**CURRENT TOLERANCE**<br>**SET UP TIME**<br>**STANDBY POWER**<br>**CONSUMPTION**<br>**Note.14**<br>**INPUT OVER VOLTAGE Note.7**<br>47 ~ 63Hz<br><0.75mA / 277VAC<br>20 ~ 95%<br>non-condensing<br>RH<br>-40 ~ +80<br>, 10 ~ 95%<br>non-condensing<br>℃<br>RH<br>10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes<br>93%<br>92.5%<br>92%<br>COLD START<br>VAC<br>50A(twidth=500 s measured at 50% Ipeak) at 230<br>;<br>μ<br>Per<br>410<br>NEMA<br>I/P-O/P:3.75<br>I/P-<br>:2<br>O/P-<br>:1.5<br>KVAC<br>FG<br>KVAC<br>FG<br>KVAC<br>I/P-O/P, I/P-<br>, O/P-<br>:100M Ohms / 500<br>/ 25<br>/ 70%<br>FG<br>FG<br>VDC<br>RH<br>℃<br>4 unit(circuit breaker of type B) / 8 units(circuit breaker of type C) at 230VAC<br>Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed<br>(Please refer to "<br>" ang “<br>"section)<br>STATIC CHARACTERISTIC<br>DRIVING METHODS OF LED MODULE<br>100 ~ 305<br>142<br>~ 431<br>VAC<br>VDC<br>VDC<br>230 ~ 265V<br>128~ 150V<br>61 ~ 78V<br>Shut down output voltage, re-power on to recovery<br>±0.06%/<br>(0 ~ 60<br>)<br>℃<br>℃<br>Tcase=-40 ~ +90<br>(Please refer to "<br>vs<br>" section)<br>℃<br>OUTPUT LOAD<br>TEMPERATURE<br>Tcase=+90℃<br>0.97 / 115<br>,<br>0.95 / 230<br>full load<br>PF<br>VAC PF<br>VAC<br>≧<br>≧<br>≧<br>,<br>0.92 / 277<br>at<br>PF<br>VAC<br>(Please refer to "<br>"<br>)<br>Power Factor Characteristic section<br>THD<br>VAC<br>VAC<br>VAC<br>< 10% (@ load<br>50% at 115<br>/230<br>,@load<br>75% at 277<br>)<br>≧<br>≧<br>Please refer to “<br>(<br>)” section<br>TOTAL HARMONIC DISTORTION THD<br>3.0%(@ full load)<br>±5%<br>500ms/230<br>, 1200ms/115<br>VAC<br>VAC<br>UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; EAC TP TC 004;IS15885(Part2/Sec13)(for XLG-150I type only);IP67 approved<br>350~1050mA<br>700mA<br>150W<br>700~1050mA<br>120 ~214V<br>225V<br>**XLG-150 -L-**<br>150W<br>1400mA<br>60 ~ 107V<br>115V<br>700~2100mA<br>1400~2100mA<br>**XLG-150 -M-**<br>150W<br>2800mA<br>27 ~ 56V<br>60V<br>1400~4170mA<br>2680~4170mA<br>**XLG-150 -H-**<br>Hiccup mode, recovers automatically after fault condition is removed<br>Standby power consumption <0.5W for AB-Type(Dimming OFF)<br>can survive input voltage stress of 440Vac for 48 hours<br>1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC<br>Adjustable for A/AB-Type only (via the built-in potentiometer)<br>**EMC**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>712.17K hrs min.<br>Telcordia<br>-332 (Bellcore) ;<br>SR<br>213.3Khrs min.<br>-<br>-217F (25<br>)<br>MIL HDBK<br>℃<br>**PACKING**<br>0.8Kg;16pcs/13.4Kg/0.67CUFT<br>**LIFETIME**<br>**Note.4** 50000 hrs min.<br>180 63<br>*<br>*35.5mm (L*W*H)<br>℃<br>℃<br>℃<br>℃<br>fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected<br>to the mains.<br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Level 2<br>Level 2<br>4.0%(@ full load)<br>3.0%(@ full load)<br>EN61547<br>EN55015(CISPR15) ,GB/T17743<br>EN55015(CISPR15) ,GB/T17743<br>EN61000-3-2 ,GB/T17625.1<br>320 ~ 390<br>(Shut down output voltage when the input voltage exceeds protection voltage,<br>)<br>VAC<br>recovers automatically after fault condition is removed<br>~~GG~~<br>~~eee~~<br>Ce~~a~~<br>~~Ce~~<br>a<br>1. All parameters NOTspecially mentioned are measured at230VAC input, rated currentand25 —_of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7. Input over voltage only for XLG-150<br>| series ,and<br>| series without UL/CSA certificate.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. The ambienttemperature derating of3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/Avww.meanwell.com<br>11. This series meetsthe typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly(t0) point (orTMP, per DLC), isabout75<br>or less.<br>12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>14. To|**XLG-150 -L-**<br>|**XLG-150 -M-**<br>|**XLG-150 -M-**<br>|**XLG-150 -H-**<br>| |---|---|---|---|---|---| ||**RATED CURRENT**<br>~~GG~~|700mA<br>~~GG~~|1400mA<br>~~GG~~||2800mA<br>~~GG~~| ||**RATED POWER**<br>~~GG~~|150W<br>~~GG~~|150W<br>~~GG~~||150W<br>~~GG~~| ||**CONSTANT CURRENT REGION**|120 ~214V|60 ~ 107V||27 ~ 56V| ||**FULL POWER CURRENT RANGE**|700~1050mA|1400~2100mA||2680~4170mA| ||**OPEN CIRCUIT VOLTAGE (max.)**|225V|115V||60V| ||**CURRENT ADJ RANGE**<br>**.**<br>~~eee~~|350~1050mA<br>700~2100mA<br>1400~4170mA<br>Adjustable for A/AB-Type only (via the built-in potentiometer)<br>~~eee~~|||| ||**CURRENT RIPPLE**|4.0%(@ full load)|3.0%(@ full load)||3.0%(@ full load)| ||**CURRENT TOLERANCE**|±5%|||| ||**SET UP TIME**|500ms/230<br>, 1200ms/115<br>VAC<br>VAC|||| ||**VOLTAGE RANGE**<br>**Note.5**|(Please refer to "<br>" ang “<br>"section)<br>STATIC CHARACTERISTIC<br>DRIVING METHODS OF LED MODULE<br>100 ~ 305<br>142<br>~ 431<br>VAC<br>VDC<br>VDC|||| ||**FREQUENCY RANGE**|47 ~ 63Hz|||| ||**POWER FACTOR (Typ.)**|0.97 / 115<br>,<br>0.95 / 230<br>full load<br>PF<br>VAC PF<br>VAC<br>≧<br>≧<br>≧<br>,<br>0.92 / 277<br>at<br>PF<br>VAC<br>(Please refer to "<br>"<br>)<br>Power Factor Characteristic section|||| ||**TOTAL HARMONIC DISTORTION**|THD<br>VAC<br>VAC<br>VAC<br>< 10% (@ load<br>50% at 115<br>/230<br>,@load<br>75% at 277<br>)<br>≧<br>≧<br>Please refer to “<br>(<br>)” section<br>TOTAL HARMONIC DISTORTION THD|||| ||**EFFICIENCY (Typ.)**|93%|92.5%||92%| ||**AC CURRENT (Typ.)**|1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC|||| ||**INRUSH CURRENT(Typ.)**|COLD START<br>VAC<br>50A(twidth=500 s measured at 50% Ipeak) at 230<br>;<br>μ<br>Per<br>410<br>NEMA|||| ||**MAX NO**<br>**PSU**<br>**.**<br>**. of**<br>**s on 16A**<br>**CIRCUIT BREAKER**|4 unit(circuit breaker of type B) / 8 units(circuit breaker of type C) at 230VAC|||| ||**LEAKAGE CURRENT**|<0.75mA / 277VAC|||| ||**STANDBY POWER**<br>**CONSUMPTION**<br>**Note.14**|Standby power consumption <0.5W for AB-Type(Dimming OFF)|||| ||**SHORT CIRCUIT**|Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed|||| ||**OVER VOLTAGE**|230 ~ 265V<br>128~ 150V<br>61 ~ 78V<br>Shut down output voltage, re-power on to recovery|||| ||**INPUT OVER VOLTAGE Note.7**|can survive input voltage stress of 440Vac for 48 hours<br>320 ~ 390<br>(Shut down output voltage when the input voltage exceeds protection voltage,<br>)<br>VAC<br>recovers automatically after fault condition is removed|||| ||**OVER TEMPERATURE**|Hiccup mode, recovers automatically after fault condition is removed|||| ||**WORKING TEMP.**|Tcase=-40 ~ +90<br>(Please refer to "<br>vs<br>" section)<br>℃<br>OUTPUT LOAD<br>TEMPERATURE|||| ||**MAX CASE TEMP**<br>**.**<br>**.**|Tcase=+90℃|||| ||**WORKING HUMIDITY**|20 ~ 95%<br>non-condensing<br>RH|||| ||**STORAGE TEMP HUMIDITY**<br>**.,**|-40 ~ +80<br>, 10 ~ 95%<br>non-condensing<br>℃<br>RH|||| ||**TEMP. COEFFICIENT**|±0.06%/<br>(0 ~ 60<br>)<br>℃<br>℃|||| ||**VIBRATION**|10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes|||| ||**SAFETY STANDARDS Note.7**|UL8750<br>ENEC EN61347-1, EN61347-2-13 independent, EN62384<br>(type”HL”), CSA C22.2 No. 250.13-12;<br>;<br>GB19510.1 GB19510.14<br>,<br>; EAC TP TC 004;IS15885(Part2/Sec13)(for XLG-150I type only);IP67 approved|||| ||**WITHSTAND VOLTAGE**|I/P-O/P:3.75<br>I/P-<br>:2<br>O/P-<br>:1.5<br>KVAC<br>FG<br>KVAC<br>FG<br>KVAC|||| ||**ISOLATION RESISTANCE**<br>**MTBF**<br>**LIFETIME**<br>**Note.4** <br>**EMC IMMUNITY**<br>**EMC EMISSION**<br>Ce|**Parameter**<br>**Standard**<br>**Test Level/Note**<br>I/P-O/P, I/P-<br>, O/P-<br>:100M Ohms / 500<br>/ 25<br>/ 70%<br>FG<br>FG<br>VDC<br>RH<br>℃|||| |||Conducted|EN55015(CISPR15) ,GB/T17743|-----|| |||Radiated|EN55015(CISPR15) ,GB/T17743|-----|| |||Harmonic Current|EN61000-3-2 ,GB/T17625.1|Class C @load≥50%|| |||Voltage Flicker<br>Ce|EN61000-3-3<br>|-----<br>|| |||EN61547<br>Ce|||| |||**Parameter**<br>Ce~~a~~|**Standard**<br>~~a~~|**Test Level/Note**<br>~~a~~|| |||ESD|EN61000-4-2|Level 3, 8KV air ; Level 2, 4KV contact|| |||Radiated|EN61000-4-3|Level 2|| |||EFT/Burst|EN61000-4-4|Level 3|| |||Surge|EN61000-4-5|4KV/Line-Line 6KV/Line-Earth(6K/10K option)|| |||Conducted|EN61000-4-6|Level 2|| |||Magnetic Field|EN61000-4-8|Level 4|| |||Voltage Dips and Interruptions|EN61000-4-11|>95% dip 0.5 periods, 30% dip 25 periods,<br>>95% interruptions 250 periods|| |||712.17K hrs min.<br>Telcordia<br>-332 (Bellcore) ;<br>SR<br>213.3Khrs min.<br>-<br>-217F (25<br>)<br>MIL HDBK<br>℃<br> 50000 hrs min.|||| ||**DIMENSION**<br>~~Ce~~|180 63<br>*<br>*35.5mm (L*W*H)<br>~~Ce~~|||| ||**PACKING**<br>0.8Kg;16pcs/13.4Kg/0.67CUFT<br>℃<br>℃<br>℃<br>℃<br>fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected<br>to the mains.<br>~~Ce~~<br>a<br>1. All parameters NOTspecially mentioned are measured at230VAC input, rated currentand25 —_of ambient temperature.<br>2. Please refer to "DRIVING METHODS OF LED MODULE".<br>3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.<br>4. Tolerance: includes set up tolerance, line regulation and load regulation.<br>5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.<br>6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.<br>7. Input over voltage only for XLG-150<br>| series ,and<br>| series without UL/CSA certificate.<br>8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the<br>complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.<br>9. The ambienttemperature derating of3.5<br>/1000m with fanless models and of<br>5<br>=/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>10. Please refer to the warranty statement on MEAN WELL's website at http:/Avww.meanwell.com<br>11. This series meetsthe typical life expectancy of>50,000 hours ofoperationwhenTcase, particularly(t0) point (orTMP, per DLC), isabout75<br>or less.<br>12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.<br>13. For any application note and IP water proof function installation caution, please refer our user manual before using.<br>https://www.meanwell.com/Upload/PDF/LED_EN.pdf<br>14. To||||| To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains. _File Name:XLG-150-SPEC 2019-07-05_ **XLG - 150 series** ## 150W Constant Power Mode LED Driver ## **BLOCK DIAGRAM** **==> picture [487 x 409] intentionally omitted <==** **----- Start of picture text -----**<br> PFC fosc : 50~120KHz<br>PWM fosc : 60~130KHz<br>EMI FILTER PFC POWER RECTIFIERS +V<br>I/P & CIRCUIT SWITCHING & -V<br>RECTIFIERS FILTER<br>O.C.P. DIM+<br>DIM-<br>(AB Type)<br>FG O.L.P. DETECTION<br>PFC PWM CIRCUIT<br>CONTROL CONTROL<br>O.T.P.<br>O.V.P.<br>DRIVING METHODS OF LED MODULE<br>※ -IV Operating Area<br>120V<br>350mA,214V 110V 700mA,107V 1400mA,107V<br>700mA,214V<br>100V<br>90V<br>80V 2100mA,71V<br>1050mA,142V<br>70V<br>60V<br>620mA,120V 1050mA,120V 1250mA,60V 2100mA,60V<br>50V<br>0mA 250mA 500mA 750mA 1000mA 1250mA 0mA 550mA 1100mA 1650mA 2200mA<br>Recommend Performance Region Recommend Performance Region<br>**----- End of picture text -----**<br> ## **DRIVING METHODS OF LED MODULE** **==> picture [216 x 165] intentionally omitted <==** **----- Start of picture text -----**<br> 240V<br>220V 350mA,214V<br>700mA,214V<br>200V<br>180V<br>160V<br>1050mA,142V<br>140V<br>120V<br>620mA,120V 1050mA,120V<br>100V<br>0mA 250mA 500mA 750mA 1000mA 1250mA<br>Recommend Performance Region<br>**----- End of picture text -----**<br> **==> picture [231 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> 60V<br>1400mA,56V 2680mA,56V<br>55V<br>50V<br>45V<br>40V 4170mA,36V<br>35V<br>30V<br>25V<br>2680mA,27V 4170mA,27V<br>20V<br>0mA 600mA 1200mA 1800mA 2400mA 3000mA 3600mA 4200mA<br>Recommend Performance Region<br>**----- End of picture text -----**<br> - ※ This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs. **==> picture [241 x 117] intentionally omitted <==** **----- Start of picture text -----**<br> 100 In the constant current<br>(B) region, the highest voltage<br>VoltageConstant(A) area Current areaConstant at the output of the driverdepends on the configuration<br>60 of the end systems.<br>(min.) Should there be any<br>(C) compatibility issues, please<br>Hiccup<br>Protection please contact MEAN WELL.<br>50 100 Io(%)<br>Typical output current normalized by rated current (%)<br>Vo(%)<br>**----- End of picture text -----**<br> _File Name:XLG-150-SPEC 2019-07-05_ **XLG - 150 series** 150W Constant Power Mode LED Driver ## **DIMMING OPERATION** **==> picture [484 x 638] intentionally omitted <==** **----- Start of picture text -----**<br> AC/N(Blue)AC/L(Brown) XLG-150 Vo-(Black) DIM-(White)DIM+(Blue)<br>FG(Green/Yellow) Vo+(Red)<br>※ 3 in 1 dimming function (for AB-Type)<br>•Output constant current level can be adjusted by applying one of the three methodologies between DIM+ and DIM-:<br>0 ~ 10VDC, or 10V PWM signal or resistance.<br>•Direct connecting to LEDs is suggested. It is not suitable to be used with additional drivers.<br>•Dimming source current from power supply: 100μA (typ.)<br>100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>+<br>Additive Voltage 30%<br>- 20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V<br>Dimming input: Additive voltage<br>100%<br>90%<br>80%<br>+<br>Vo+ + 70%<br>60%<br>-<br>Vo- - 50%<br>DIM+ 40%<br>Additive PWM signal 30%<br>20%<br>DIM-<br>10%<br>“DO NOT connect "DIM- to Vo-" 0%<br>0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%<br>Duty cycle of additive 10V PWM signal dimming input<br>100%<br>90%<br>Vo+ + + 80%<br>70%<br>-<br>Vo- - 60%<br>DIM+ 50%<br>40%<br>Additive Resistance<br>30%<br>DIM- 20%<br>“DO NOT connect "DIM- to Vo-" 10%<br>0%<br>Short 10K/N 20K/N 30K/N 40K/N 50K/N 60K/N 70K/N 80K/N 90K/N 100K/N<br>(N=driver quantity for synchronized dimming operation)<br>Dimming input: Additive resistance<br>Note : 1. Min. dimming level is about 8% and the output current is not defined when 0%< Iout<8%.<br>2. The output current could drop down to 0% when dimming input is about 0kΩ or 0Vdc, or 10V PWM signal with 0% duty cycle.<br>Output current (%)<br>Output current (%)<br>Output current (%)<br>**----- End of picture text -----**<br> _File Name:XLG-150-SPEC 2019-07-05_ **XLG - 150 series** 150W Constant Power Mode LED Driver ## **OUTPUT LOAD vs TEMPERATURE** **==> picture [491 x 395] intentionally omitted <==** **----- Start of picture text -----**<br> 230VAC<br>100 100<br>90<br>80 2 30VAC 80<br>230VAC<br>Input only 100VAC Input only<br>60 60<br>40 40<br>20 20<br>-40 -30 -10 0 15 30 40 55 70 (HORIZONTAL) -40 -30 0 10 30 50 70 90 (HORIZONTAL)<br>If XLG-150 operates in Constant Current mode with the rated<br>current the maximum workable Ta is 55℃ (Typ. 230VAC) or 40℃(Typ.100VAC)<br>Below 110VAC@ -30℃ may retry to 2nd setup<br>STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC<br>※ Tcase at 75℃<br>Constant Current Mode<br>100<br>1<br>90 0.98<br>0.96<br>80<br>0.94<br>70 0.92<br>277V<br>0.9<br>60 0.88 230V<br>50 0.86 115V<br>0.84<br>40<br>0.82<br>0.8<br>100 110 140 160 180 200 220 240 260 280 305 50% 60% 70% 80% 90%<br>INPUT VOLTAGE (V) 60Hz LOAD<br>LOAD (%) LOAD (%)<br>LOAD (%)<br>PF<br>**----- End of picture text -----**<br> ## **TOTAL HARMONIC DISTORTION (THD)** ## **EFFICIENCY vs LOAD** XLG-150 series possess superior working efficiency that up to 93% can be reached in field applications. **==> picture [243 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> ※ XLG-150-L Model, Tcase at 75℃<br>11%<br>10%<br>9%<br>8%<br>7%<br>277V<br>6%<br>5% 230V<br>4% 115V<br>3%<br>2%<br>1%<br>0%<br>50% 60% 70% 80% 90% 100%<br>LOAD<br>THD<br>**----- End of picture text -----**<br> **==> picture [244 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> ※ XLG-150-L Model, Tcase at 75℃<br>96<br>92<br>88<br>84<br>277V<br>80<br>230V<br>76 115V<br>72<br>68<br>64<br>60<br>50% 60% 70% 80% 90%<br>EFFICIENCY(%)<br>**----- End of picture text -----**<br> **==> picture [20 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> LOAD<br>**----- End of picture text -----**<br> _File Name:XLG-150-SPEC 2019-07-05_ **XLG - 150 series** 150W Constant Power Mode LED Driver ## **LIFE TIME** **==> picture [392 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> 120<br>100<br>80<br>60<br>40<br>20<br>0<br>25 30 35 40 45 50 55 60 65 70 75 80 85 90<br>Tcase ( ) ℃<br>(Kh)<br>LIFETIME<br>**----- End of picture text -----**<br> _File Name:XLG-150-SPEC 2019-07-05_ **XLG - 150 series** ## 150W Constant Power Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> MECHANICAL SPECIFICATION Case No.: 243A Unit:mm<br>※ Blank-Type<br>180<br>169<br>300±20 156 300±20<br>AC/N(Blue) Vo-(Black)<br>AC/L(Brown)FG(Green/Yellow) &H05RN-F 3x1.0mmSJOW 17AWGx3C 2 tc 70 SJOW 17AWGx2C&05RN-F 2x1.0mmVo+(Red) 2(for H,L,M)<br>SJOW 14AWGx2C(for 12,24V)<br>4-ψ4.5<br>tc<br>※ A-Type<br>180<br>169<br>300±20 156 300±20<br>AC/N(Blue) Vo-(Black)<br>AC/L(Brown)FG(Green/Yellow) SJOW 17AWGx3C 2 tc 70 SJOW 17AWGx2C&05RN-F 2x1.0mmVo+(Red) 2(for H,L,M)<br>&H05RN-F 3x1.0mm<br>SJOW 14AWGx2C(for 12,24V)<br>4-ψ4.5<br>tc<br>38.3<br>14<br>45.8 63<br>22<br>35 35.5<br>45.8 63<br>22<br>35 35.5<br>**----- End of picture text -----**<br> _File Name:XLG-150-SPEC 2019-07-05_ **XLG - 150 series** ## 150W Constant Power Mode LED Driver **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> ※ AB-Type<br>180<br>169<br>300±20 156 350±20<br>UL2517 20AWGx2C<br>AC/N(Blue) DIM+(Blue)<br>AC/L(Brown)FG(Green/Yellow) SJOW 17AWGx3C tc 70 Vo-(Black)Vo+(Red) DIM-(White)<br>&H05RN-F 3x1.0mm2 SJOW 17AWGx2C<br>&05RN-F 2x1.0mm2<br>4-ψ4.5 300±20<br>tc<br>INSTALLATION MANUAL<br>35 35.5<br>45.8 63<br>22<br>**----- End of picture text -----**<br> _File Name:XLG-150-SPEC 2019-07-05_
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →