- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- Product Range: XDR-960 Series
- No. of Outputs: 1 Output
- Output Power Max: 960W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 20A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Laboratory Equipment
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 216.08 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [469 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
-<br>960W AC/DC High-End Ultra Slim Industrial DIN Rail Power XDR 960 series<br>_<br>\\ | \ | \ |<br> <br> <br>**----- End of picture text -----**<br>
## **(XDR-960-xx)**
**(XDR-960-xxLA)**
**==> picture [62 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
(XDR-960-xxPI)<br>**----- End of picture text -----**<br>
**==> picture [521 x 150] intentionally omitted <==**
**----- Start of picture text -----**<br>
Characteristics VerifiedVoltage Sag Immunity SEMI F47 BauarSicherheitbeegelodwacmat geprufto ges g<br>DNV www.ID 2000000000tuv.com<br>B® =) (GL type) DNV.COM/AF BO:LISTED OW:LISTED BS EN/EN62368-1BS EN/EN61558-1 CB IEC62368-1IEC61558-1 & (Note.5)<br>1 UL61010 BS EN/EN61010 IEC61010<br>IS 13252<br>THOMAS SAMUEL THOMAS SAMUEL<br>By request KC62368-1 ce& CNS15598-1 S GB4943 @ . 1 IACE TPTC004 &<br>( Note.6 ) (By request)<br>■ ■ <br>‧ ‧<br>‧ ‧<br>‧<br> <br>‧ ‧<br>EAPPROVED RPOD<br>V E R I F I E D verify.UV437575L.com<br>TYP UCT<br>**----- End of picture text -----**<br>
- ‧
- ‧ ‧ ‧ ‧ ‧
## ■ ****
- ‧ ‧ ‧ ‧Ⅲ Ⅲ ‧
https://www.meanwell.com/serviceGTIN.aspx
- ‧
‧ ‧ ‧ ‧ ‧ • ‧ ■ **** ℃℃ ■ ** ** ni ~~e~~ ee
_File Name:XDR-960-SPEC 2026-01-22_
**- XDR 960 series**
960W AC/DC High-End Ultra Slim Industrial DIN Rail Power
|**SPECIFICATION**|**SPECIFICATION**|**XDR-960-36**<br>**XDR-960-24**<br>=Blank, LA, PI<br>**XDR-960-48**<br>=Blank, GL|**XDR-960-36**<br>**XDR-960-24**<br>=Blank, LA, PI<br>**XDR-960-48**<br>=Blank, GL|**XDR-960-36**<br>**XDR-960-24**<br>=Blank, LA, PI<br>**XDR-960-48**<br>=Blank, GL|**XDR-960-36**<br>**XDR-960-24**<br>=Blank, LA, PI<br>**XDR-960-48**<br>=Blank, GL|
|---|---|---|---|---|---|
|**OUTPUT**||||||
|**DC VOLTAGE**||24V|36V||48V|
|**LOAD CURRENT RANGE**||0 ~ 40A|0 ~ 26.6A||0 ~ 20A|
|**RATED POWER**||960W|957.6W||960W|
|**PEAK**|**CURRENT (5sec.)**<br>**POWER (5sec.)**|80A<br>1920W<br>53.3A<br>40A||||
|**Note.2**<br>**RIPPLE & NOISE (max.)**||100mVp-p|120mVp-p||150mVp-p|
|**VOLTAGE ADJ. RANGE**||24 ~ 29V|36 ~ 42V||48 ~ 55V|
|**Note.3**<br>**VOLTAGE TOLERANCE**||±1.0%|±1.0%||±1.0%|
|**LINE REGULATION**||±0.5%|±0.5%||±0.5%|
|**LOAD REGULATION**||±1.0%|±1.0%||±1.0%|
|**SETUP, RISE TIME**||1500ms, 100ms/277Vac 1500ms, 100ms/230Vac 1500ms, 100ms/115Vac at full load||||
|**HOLD UP TIME (Typ.)**||20ms/277Vac 20ms/230Vac 20ms/115Vac at full load||||
|**INPUT**||||||
|**AC VOLTAGE RANGE**||85 ~305Vac||||
|**DC VOLTAGE RANGE**||80 ~ 431Vdc (Derating50% Load @80Vdc)||||
|**CONSUMPTION(Typ.)**<br>**NO LOAD**|**Remote Power OFF**<br>**Remote Power ON**|1.5W@115Vac & 230Vac & 277Vac<br>6.7W@115Vac<br>4.5W<br>230<br>@<br>Vac & 277Vac||||
|**FREQUENCY RANGE**||47 ~ 63Hz||||
|**POWER FACTOR (Typ.)**||PF>0.98/115VacPF>0.95/230Vac<br>0<br>at full load<br>PF> .9/277Vac||||
|**EFFICIENCY (Typ.)**||95%|95.5%||96%|
|**AC CURRENT (Typ.)**||10A/115Vac 5A/230Vac 4.2A/277Vac||||
|**INRUSH CURRENT (Typ.)**||COLD START<br>23A/115Vac 10A/230Vac 15A/277Vac||||
|**LEAKAGE CURRENT**||<3.5mA / 240Vac <4.5mA / 277Vac||||
|**PROTECTION**||||||
|**OVERLOAD**||105%~200% rated output power for more than 5 sec then<br>at rate current<br> when Vo=30%~100%<br>constant current limiting<br>without shutdown<br>Hiccup mode when Vo<30% rated voltage||||
|**OVER VOLTAGE**||30 ~ 34V<br>57 ~ 66V<br>43 ~ 50V<br>Protection type : Shut down o/p voltage, re-power on to recover||||
|**OVER TEMPERATURE**||Protection type : Shut down o/p voltage, recovers automatically after temperature goes down||||
|**FUNCTION**||||||
|**PARALLEL**||Up to<br>units; Please refer to<br>for more details.<br>3840W (3+1)<br>Function Manual||||
|**DC OK RELAY CONTACT**||Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5A resistive load||||
|**REMOTE CONTROL**||Power ON :RC(Pin9) and 5V_AUX(Pin10) short .<br>Power OFF:RC(Pin9) and 5V_AUX(Pin10) open.||Please refer to<br>for more details.<br>Function Manual||
|**MODBus INTERFACE**||Communication provides functions such as control, setting, and monitoring.||||
|**TRANSIENT PEAK CURRENT CAPABLILTY**||600% rated current for 15ms||||
|**ENVIRONMENT**||||||
|**WORKING TEMP.**||-40 ~ +85℃(Refer to "Derating Curve")||||
|**WORKING HUMIDITY**||20 ~ 95% RH non-condensing||||
|**STORAGE TEMP., HUMIDITY**||-40 ~ +85℃, 10 ~ 95% RH non-condensing||||
|**TEMP. COEFFICIENT**||±0.03%/℃(0 ~ 60℃)||||
|**VIBRATION**||Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||
_File Name:XDR-960-SPEC 2026-01-22_
**- XDR 960 series**
960W AC/DC High-End Ultra Slim Industrial DIN Rail Power
|**SPECIFICATION**|**XDR-960-36**<br>**XDR-960-24**<br>=Blank, LA, PI<br>**XDR-960-48**<br>=Blank, GL|**XDR-960-36**<br>**XDR-960-24**<br>=Blank, LA, PI<br>**XDR-960-48**<br>=Blank, GL|**XDR-960-36**<br>**XDR-960-24**<br>=Blank, LA, PI<br>**XDR-960-48**<br>=Blank, GL|
|---|---|---|---|
|**SAFETY & EMC**<br>**Note.4&5&6**||||
|**SAFETY STANDARDS**|CB<br>TUV<br>UL<br>CCC<br>BSMI<br>EAC<br>Marine DNV (for GL type only)<br>SEMI F47<br>KC/BIS<br>IEC62368-1, IEC61558-1/-2-16, IEC61010-1/-2-201<br>BS EN/EN62368-1,BS EN/EN61558-1/-2-16,BS EN/EN61010-1/-2-201<br>;UL61010-1/-2-201<br>UL121201/CSA C22.2 NO.213.17 Class I,DIV2 Group A,B,C,D Hazardous Locations T4<br>GB4943.1<br>CNS15598-1<br>TPTC004<br>approved<br>KC62368-1 and BIS IS 13252 (Part 1) certifed, no stock by request ,contact sales for inquires|||
|**OVER VOLTAGE CATEGORY**<br>**Note.7**|IEC/EN 61558-1/-2-16 (<br>altitude up to 2000m )<br>OVCⅢ,<br>IEC/EN/UL 61010-1/-2-201 (OVC<br>, altitude up to<br>)<br>Ⅱ<br>000m<br>5<br>IEC/EN 62368-1 (OVC<br>, altitude up to<br>)<br>Ⅱ<br>5000m|||
|**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**|IEC/EN 61558-2-16 (<br>SELV)<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1|||
|**WITHSTAND VOLTAGE**|I/P-O/P:<br>I/P-FG: 2KVac O/P-FG: 1.5KVac O/P-DC OK: 0.5KVac<br>4KVac|||
|**EMC EMISSION**<br>**EMC IMMUNITY**<br>**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/ 70%RH|||
||**Parameter**|**Standard**|**Test Level / Note**|
||Conducted|BS EN/EN55032 (CISPR32)/<br>BS EN/EN61204-3 / CNS15936 / KS C 9832|Class B|
||Radiated|BS EN/EN55032 (CISPR32)/<br>BS EN/EN61204-3 / CNS15936 / KS C 9832|Class B|
||Harmonic Current|BS EN/EN61000-3-2|Class A|
||Voltage Flicker|BS EN/EN61000-3-3|-----|
||BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2),KS C 9835,SEMI F47 tested at 200Vac|||
||**Parameter**|**Standard**|**Test Level / Note**|
||ESD|BS EN/EN61000-4-2|Level 4,<br>air ; Level ,<br>contact;<br>15KV<br>4 8KV<br>criteria A|
||Radiated|BS EN/EN61000-4-3|Level 3, 10V/m ; criteria A|
||EFT / Burst|BS EN/EN61000-4-4|Level 4, 4KV ; criteria A|
||Surge|BS EN/EN61000-4-5|Level 4, 2KV/Line-Line ;Level 4,<br>4KV/Line-Line-Chassis ;criteria A|
||Conducted|BS EN/EN61000-4-6|Level 3, 10V ; criteria A|
||Magnetic Field|BS EN/EN61000-4-8|Level 4, 30A/m ; criteria A|
|**OTHERS**||||
|**MTBF**|819.6K hrs min. Telcordia SR-332 (Bellcore); 113.3K hrs min. MIL-HDBK-217F (25℃)|||
|**DIMENSION**|**96*125.2*132mm (W*H*D)**|||
|**PACKING**|2.06Kg; 6pcs/ 13.4Kg /1.49CUFT|||
|**NOTE**||||
|℃<br>μ μ <br><br><br><br><br><br><br><br><br><br><br><br>℃<br>℃<br><br><br>※:||||
- ℃
- μμ
-
-
-
- ℃℃
- ※:
_File Name:XDR-960-SPEC 2026-01-22_
**- XDR 960 series**
## 960W AC/DC High-End Ultra Slim Industrial DIN Rail Power
**==> picture [489 x 650] intentionally omitted <==**
**----- Start of picture text -----**<br>
Block Diagram PFC fosc : 70KHz<br>PWM fosc : 65KHz<br>EMI RECTIFIER POWER RECTIFIERS ORING FET +Vo<br>Input FILTER & SWITCHING & -Vo<br>PFC FILTER<br>O.V.P.<br>FG PFC PWM<br>CONTROL CONTROL<br>CURRENT<br>DETECTION<br>O.T.P<br>AUX<br>POWER MCU PARALLEL CS<br>GND<br>RELAY<br>DC OK<br>O.T.P MCU CONTROL<br>TRANSIENT TC<br>PEAK CURRENT GND<br>PHOTO 5V_AUX<br>RECTIFIERS COUPLER<br>& ISOLATION RC<br>FILTER<br>RECTIFIERS DATA D+<br>& ISOLATION D-<br>FILTER<br>Derating Curve<br>Suitable for 100/110/115/120Vac System Suitable for 220/230/240/277Vac System<br>(85~132Vac) (180~305Vac)<br>200<br>Please refer to Function Please refer to Function<br>Manual of peak power Manual of peak power<br>150<br>150<br>120<br>100<br>90 100<br>80 80<br>75<br>60<br>40<br>20 20<br>-40 -30 0 55 60 70 85 (VERTICAL) -40 -30 0 60 70 85 (VERTICAL)<br>AMBIENT TEMPERATURE ( ℃ ) AMBIENT TEMPERATURE ( ℃ )<br>Output derating VS input voltage<br>100 100<br>90<br>85 85<br>80<br>70<br>50<br>60<br>50<br>40<br>85 100 115 120 180 220 240 277 305 80 120140 220 240 431<br>INPUT VOLTAGE (Vac) 60Hz INPUT VOLTAGE (Vdc)<br>LOAD (%) LOAD (%)<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br>
_File Name:XDR-960-SPEC 2026-01-22_
**-** 960W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 960 series**
## **Peak Power**
**==> picture [396 x 359] intentionally omitted <==**
**----- Start of picture text -----**<br>
Pav = P pk [x] t + PT npk x [(T-t)] ≤ Prated Pav : Average output power�(W)<br>Ppk : Peak output power��(W)<br>t<br>Duty = T x 100% ≤ 35% Pnpk : Non-peak output power(W)<br>t�≤ 5 sec<br>Prated : Rated output power(W)<br>t : Peak power width(sec)<br>P pk T : Period(sec)<br>P av<br>P npk<br>t<br>T<br>100Vac<br>200Vac<br>40<br>35<br>30<br>25<br>20<br>15<br>10<br>5<br>1040W 1200W 1440W 1680W 1920W<br>(108%) (125%) (150%) (175%) (200%)<br>Peak output power (W)<br>Duty(%)<br>**----- End of picture text -----**<br>
**For example (24V model) :**
Vin = 200Vac Duty_max = 5% P av= P rated = 960W P pk= 1920W t�≤ 5 sec
5 sec T ≥ 5% ≥ 100sec P npk ≤ T PavT-tt P pk P npk[≤] 909.5W
_File Name:XDR-960-SPEC 2026-01-22_
**-** 960W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 960 series**
## **Transient peak current Capability**
**==> picture [350 x 171] intentionally omitted <==**
**----- Start of picture text -----**<br>
※�The power supply can provide transient peak current to support the start-up of inductive or capacitive loads.<br>The maximum duration and voltage dips are explained below.<br>Vo<br>100~132Vac<br>66 180~305Vac<br>50<br>40<br>37<br>30<br>10<br>3 XIo 4 XIo 5 XIo 6 XIo<br>Vo (%)<br>**----- End of picture text -----**<br>
**Transient peak current voltage dip**
**==> picture [245 x 78] intentionally omitted <==**
**----- Start of picture text -----**<br>
100~132Vac 180~305Vac Time<br>Load<br>Vo(%) Vo(%) (Max.)<br>3xIo 50 66 100ms<br>4xIo 37 50 70ms<br>5xIo 30 40 40ms<br>6xIo 10 10 15ms<br>**----- End of picture text -----**<br>
※�After a transient peak current event occurs, the rated load must be maintained for at least 15 seconds before the next event.
**For example : (600% transient peak current)**
**==> picture [398 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
15ms 15ms 15ms<br>6xIo<br>......<br>1xIo<br>0 15s 15s<br>**----- End of picture text -----**<br>
_File Name:XDR-960-SPEC 2026-01-22_
**-** 960W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 960 series**
## **Function Manual**
|**Pin No.**|**Function**|**Description**|
|---|---|---|
|||Contact close : PSU turns ON/DC_OK ;|
|1,2|DC OK<br>Relay Contact|Contact open : PSU turns OFF/DC_fail;<br>Contact ratings (max.): 30Vdc/1A ,30Vac/0.5A resistive load.|
|3|GND|When units are connected in parallel, the GND pins of the units should be connected mutually<br>to allow current balance between units.|
|4|CS|Current sharing signal. When units are connected in parallel, the CS pins of the units should<br>be connected mutually to allow current balance between units.|
|5|TC (Note.1)|The unit can enable the transient peak current by dry contact between TC(Pin5) and GND(Pin3).<br>Power ON: Short; Power OFF: Open.|
|6|D-(Note.2)|Data line used in MODBUS interface|
|8|D+ (Note.2)||
|7|GND_AUX|The signal return is isolated from the output terminal. (+Vo & -Vo)|
|||The unit can turn the output ON/OFF by electrical signal or dry contact between|
|9|RC (Note.2)|RC ON/OFF(Pin9) and 5V_AUX(Pin10).|
|||Power ON: Short(4~5Vdc);Power OFF: Open(<0.5Vdc);The Maximum input voltage is 5Vdc.|
|10|5V_AUX|For remote control signal only. Isolated from the output terminals.|
Note1: Non-isolated signal, referenced to GND. Note2: lsolated signal, referenced to GND-AUX.
**==> picture [188 x 193] intentionally omitted <==**
**----- Start of picture text -----**<br>
+Vo +Vo +Vo Vo Vo Vo<br>24V 40A Status<br>Vo Adj.<br>MW nee@ 960W Max24-29Vdc.<br>DC OK DC OK<br>CS GND<br>D- TC<br>5V_AUXD+ RCGND AUX_<br>XDR-960-24<br>100-277Vac<br>L N ©<br>**----- End of picture text -----**<br>
**==> picture [126 x 70] intentionally omitted <==**
**----- Start of picture text -----**<br>
DC OK 2 1 DC OK<br>CS 4 3 GND<br>D- 6 5 TC<br>D+ 8 7 GND_AUX<br>5V_AUX 10 9 RC<br>**----- End of picture text -----**<br>
_File Name:XDR-960-SPEC 2026-01-22_
**-** 960W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 960 series**
## **1.Parallel Use**
- XDR-960 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : (1) The transient peak current capability needs to be disabled,The TC pin of the units cannot be connected to GND .
- (2) Parallel operation is available by connecting the units shown as below (CS,GND are connected mutually in parallel).
- (3) Difference of output voltages among parallel units should be less than 0.2V.
- (4) The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9.
- (5) In parallel operation 4 units is the maximum, please consult the manufacture for other applications.
- (6) The power supplies should be paralleled using short and large diameter wiring and then connected to the load.
**==> picture [443 x 512] intentionally omitted <==**
**----- Start of picture text -----**<br>
(7) When in parallel operation, the minimum output load should be greater than 5% of total output load.<br> (Min. load >5% rated current per unit x number of unit)<br>(8) In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition.<br>The other PSUs (slaves) may go into standby mode and their output Green LEDs & relays will not turn on.<br>(9) CS and GND lines should be twisted in pairs.<br>Te)ai<br>Pin : 4 CS {o> Pin 3 : GND<br>+ -<br>| oa all<br>LOAD<br>10 9<br>+Vo<br>pe “<br>-Vo<br>GND<br>CS<br>; 1 To 2 3 4 5 6 . ; 1 TO 2 3 4 5 6 ; 1 TO 2 3 4 5 6 . ; 1 TO 2 3 4 5 6 .<br>+Vo+Vo +Vo -Vo -Vo -Vo +Vo+Vo +Vo -Vo -Vo -Vo +Vo+Vo +Vo -Vo -Vo -Vo +Vo+Vo +Vo -Vo -Vo -Vo<br>Status Status Status Status<br>Vo Adj. Vo Adj. Vo Adj. Vo Adj.<br>5V_AUXDC OKDD+CS- EF DC OKRCGNDGND AUXTC _ 5V_AUXDC OKDD+CS- ED DC OKRCGNDGND AUXTC _ 5V_AUXDC OKDD+CS- EF DC OKRCGNDGND AUXTC _ 5V_AUXDC OKDD+CS- ED DC OKRCGNDGND AUXTC _<br>XDR-960 XDR-960 XDR-960 XDR-960<br>PSU1 PSU2 PSU3 PSU4<br>100-277Vac 100-277Vac 100-277Vac 100-277Vac<br>L N L N L N L N<br>1 2 3 1 2 3 1 2 3 1 2 3<br>a we) Lo 7 Lo 7 Lor7<br>2. Support MODBus Communication<br>Communication provides functions such as control, setting, and monitoring. 2 1<br>Parameters include output voltage, output power, input voltage, etc<br>For details, Please refer to: http://www.meanwell.com/manual.html Pin 6 : D-Pin 8 : D+ Pin 7 :GND_AUX<br>10 9<br>Srye ehh<br>le<br>RS-485 to USB<br>Communication isolation converter To the personal<br>cable computer USB port<br>Personal Computer<br>**----- End of picture text -----**<br>
## **2. Support MODBus Communication**
_File Name:XDR-960-SPEC 2026-01-22_
**-** 960W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 960 series**
**==> picture [461 x 445] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 . DC OK Relay Contact<br>Contact Close PSU turns ON / DC OK. Pin 2 : DC OK Pin 1 :DC OK<br>Contact Open PSU turns OFF / DC Fail.<br>10 9<br>Contact Ratings (max.) 30Vdc/1A ,30Vac/0.5A resistive load.<br>1<br>R<br>U External voltage source (U) and resistor (R)<br>(The max. Sink is 30Vdc/1A ,30Vac/0.5A)<br>2<br>Internal circuit of DC_OK, via relay contact<br>4.Remote ON/OFF Control<br>The PSU can be turned ON/OFF by using the "Remote Control" function.<br>PSU Vo Status Between RC(Pin9) and 5V_AUX(Pin10) 2 1<br>Remote power ON Short (Pin9=4~5V)<br>Pin 10 : 5V_AUX Pin 9 :RC<br>Remote power OFF Open (Pin9=0~0.5V)<br>Pin 9 User’s Optocoupler 5Vdc(max.) Relay<br>Pin 10 User’s power Pin 9 Pin 9<br>3<br>User’s PSU 2 1 User’s PSU<br>Pin 9 User’s power GND Pin 7 Pin 10<br>Pin 10<br>R.C. by external switch. R.C. by user’s optocoupler control module. auxiliary powerR.C. by user’s external . R.C. by user’s Relay control module.<br>**----- End of picture text -----**<br>
## **4.Remote ON/OFF Control**
## **5.Protection Against Inverse Voltages From The Load**
Prevent PSU damage from Back Electro magnetic Force during deceleration of motor or inductive load.
**==> picture [419 x 86] intentionally omitted <==**
**----- Start of picture text -----**<br>
AC + + PSU'S ORing FET turn OFF voltage<br>MODEL Max. allowable reverse voltage<br>Io<br>DC<br>XDR-960-24 <35V<br>DC - - XDR-960-36 <50V<br>(XDR-960) (DC Load)<br>XDR-960-48 <63V<br>**----- End of picture text -----**<br>
_File Name:XDR-960-SPEC 2026-01-22_
**- XDR 960 series**
960W AC/DC High-End Ultra Slim Industrial DIN Rail Power
## **6.LED Status Indictors**
||Output of alarm|Output of alarm|
|---|---|---|
|Description|Output of alarm||
|Restore Factory Settings|Green : 3 Blink||
|DC OK|Green||
|DC Fail|Red||
|Overload<br>(115Vac: >150% rated current)<br>(230Vac: >200% rated current)|Red : 1 Blink/Pause||
|Over voltage|Red : 2 Blink/Pause||
|Over temperature|Red : 3 Blink/Pause||
|Against Inverse Voltages From The Load|Red : 4 Blink/Pause||
|High Ambient Temperature Warning|Red : Blink||
|Others (Note)|Red : 5 Blink/Pause||
Note: Others include protection status AC UVP、Internal Communication error and EEPROM error.
_File Name:XDR-960-SPEC 2026-01-22_
**-** 960W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 960 series**
**==> picture [486 x 493] intentionally omitted <==**
**----- Start of picture text -----**<br>
Mechanical Specification<br>(Unit:mm , Tolerance ±1mm)<br>Case No. 304<br>B : Control Pin No. Assignment:JS-2008R-2x05<br> or equivalent<br>Mating Housing Terminal<br>JS-2007-2x05-BK JS-2007-T or<br>or equivalent equivalent<br>Pin No. Assignment<br>1,2 DC OK<br>3 GND(Current sharing)<br>4 CS(Current sharing)<br>A : Terminal Pin No.Assignment 5 TC<br>Pin No. Assignment 6 D-<br>1,2,3 DC Output +Vo 7 GND_AUX<br>4,5,6 DC Output -Vo 8 D+<br>9 RC<br>10 5V_AUX<br>96<br>1 2 3 4 5 6<br>A<br>+Vo+Vo +Vo -Vo -Vo -Vo<br>Status<br>Vo Adj.<br>5V_AUXDC OKDD+CS- DC OKRCGNDGND AUXTC _ B<br>100-277Vac<br>L N<br>C<br>1 2 3<br>C : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1 AC/L or DC Input +Vin<br>2 AC/N or DC Input -Vin<br>3 FG<br>132<br>2125 .<br>**----- End of picture text -----**<br>
**==> picture [273 x 142] intentionally omitted <==**
**----- Start of picture text -----**<br>
Recommend Wiring<br>AC Input T.B DC Output T.B<br>Solid Wire 6mm max.2 6mm max.2<br>A.W.G 18~10 AWG 16~10 AWG<br>Blank 10~11mm 10~11mm<br>Wire Stripping Length LA 11~12mm 11~12mm<br>PI 14~15mm 14~15mm<br>Blank 5 Lb-In 5 Lb-In<br>Screw Terminal Torque<br>LA/PI Not applicable<br>**----- End of picture text -----**<br>
_File Name:XDR-960-SPEC 2026-01-22_
**-** 960W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 960 series**
## **Accessory List**
**==> picture [444 x 599] intentionally omitted <==**
**----- Start of picture text -----**<br>
Communication interface mating wire (standard accessory)<br>i No. Item Quantity<br>50<br>——___<br>1 Mating wire H20J1-10B UL1007 28AWG 1pcs/per model<br>or equivalent<br>Accessory List and Installation Diagram for GL Type<br>·The GL Type model is recommended for GNV certification or high vibration application.<br>·The GL Type model include the following accessories.<br>a NO. Item Quantity<br>1 GL installation bracket 2<br>2 Screw(M3*8) 4<br>eeee ee<br>3 Screw(M4*8) 4<br>※ GL Type mechanical specification<br>68.8 mm<br>48.8 mm 58.8 mm<br>° ° PLP<br>I a,<br>:<br>L°4<br>.|p Ph<br>4-φ5<br>165.8 mm 125.2 mm<br>152.9 mm<br>**----- End of picture text -----**<br>
## **Accessory List and Installation Diagram for GL Type**
_File Name:XDR-960-SPEC 2026-01-22_
**==> picture [65 x 40] intentionally omitted <==**
**==> picture [439 x 26] intentionally omitted <==**
**----- Start of picture text -----**<br>
-<br>960W AC/DC High-End Ultra Slim Industrial DIN Rail Power XDR 960 series<br>**----- End of picture text -----**<br>
**==> picture [511 x 668] intentionally omitted <==**
**----- Start of picture text -----**<br>
※ GL Type installation steps<br>Step1 Step2 Step3<br>140.84 mm<br>2-M4<br>4-M3<br>2-M4<br>Detach the DIN Rail clip by removing screws. Mount the steel brackets to the back of the Mount the XDR-960 power supply directly to<br>case with M3*8 (L=8mm) screws. the wall/panel through the mounting holes on<br>Recommended screw torque setting is 5 Lb-In. the brackets.<br>Installation Instruction<br>This series fits DIN rail TS35/7.5 or TS35/15.<br>For installation details, please refer to the Instruction manual.<br>ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>Installation Manual<br>Please refer to : http://www.meanwell.com/manual.html<br>35<br>**----- End of picture text -----**<br>
_File Name:XDR-960-SPEC 2026-01-22_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →