Image not available
Illustrative purposes only
XDR-480-12PI
AC/DC DIN Rail Power Supply (PSU), Push-In, ITE, Industrial & Laboratory Equipment, 1 Output, 360 W
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- Product Range: XDR-480 Series
- No. of Outputs: 1 Output
- Output Power Max: 360W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 30A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Laboratory Equipment
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 165.87 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [438 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> -<br>480W AC/DC High-End Ultra Slim Industrial DIN Rail Power XDR 480 series<br>ee<br>(XDR-480-xx) (XDR-480-xxLA) (XDR-480-xxPI)<br> <br><br> <br> <br><br>**----- End of picture text -----**<br> **==> picture [521 x 199] intentionally omitted <==** **----- Start of picture text -----**<br> (XDR-480-xx) (XDR-480-xxLA) (XDR-480-xxPI)<br>Characteristics VerifiedVoltage Sag Immunity SEMI F47 BauarSicherheitbeegelodwacmat geprufto ges g<br>DNV www.ID 2000000000tuv.com<br>BE =) DNV.COM/AF BF/ O«LISTED WsLISTED BS EN/EN62368-1BS EN/EN61558-1 CB IEC62368-1IEC61558-1 & (Note.5)<br>1 UL61010 BS EN/EN61010 IEC61010<br>IS 13252<br>THOMAS SAMUEL THOMAS SAMUEL<br>By request KC62368-1 “Ee CNS15598-1 G S GB4943 @ . 1 FICE TPTC004 XS<br>( Note.6 ) (By request)<br>■ ■ <br>‧ ‧<br>‧ ‧<br>‧<br> <br>‧ ‧<br><br>‧<br>‧<br>EAPPROVED RPOD<br>V E R I F I E D verify.UV437575L.com<br>TYP UCT<br>**----- End of picture text -----**<br> - ‧ - ‧ - ‧ ‧ ‧ ‧ ‧Ⅲ Ⅲ ## ■ **** https://www.meanwell.com/serviceGTIN.aspx - ‧ - ‧ - ‧ - ‧ ‧ ‧ ‧ • ‧ ■ **** ℃ ℃ ■ **** ee ** ** ~~LIC~~ ee ee _ ee se _File Name:XDR-480-SPEC 2026-01-22_ **-** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 480 series** |**SPECIFICATION**|**SPECIFICATION**|**XDR-480-36**<br>**XDR-480-24**<br>**XDR-480-12**<br>**XDR-480-48**<br>=Blank, LA, PI|**XDR-480-36**<br>**XDR-480-24**<br>**XDR-480-12**<br>**XDR-480-48**<br>=Blank, LA, PI|**XDR-480-36**<br>**XDR-480-24**<br>**XDR-480-12**<br>**XDR-480-48**<br>=Blank, LA, PI|**XDR-480-36**<br>**XDR-480-24**<br>**XDR-480-12**<br>**XDR-480-48**<br>=Blank, LA, PI|**XDR-480-36**<br>**XDR-480-24**<br>**XDR-480-12**<br>**XDR-480-48**<br>=Blank, LA, PI| |---|---|---|---|---|---|---| |**OUTPUT**||||||| |**DC VOLTAGE**||12V|24V||36V|48V| |**LOAD CURRENT RANGE**||0 ~ 30A|0 ~ 20A||0 ~ 13.3A|0 ~ 10A| |**RATED POWER**||360W|480W|||| |**PEAK**|**CURRENT (5sec.)**<br>**POWER (5sec.)**|60A<br>720W|26.6A<br>20A<br>40A<br>960W|||| |**Note.2**<br>**RIPPLE & NOISE (max.)**||100mVp-p|100mVp-p||120mVp-p|120mVp-p| |**VOLTAGE ADJ. RANGE**||12 ~ 15V|24 ~ 29V||36 ~ 42V|48 ~ 55V| |**Note.3**<br>**VOLTAGE TOLERANCE**||±1.0%|1.0%<br>±||±1.0%|±1.0%| |**LINE REGULATION**||±0.5%|0.5%<br>±||±0.5%|±0.5%| |**LOAD REGULATION**||±1.0%|1.0%<br>±||±1.0%|±1.0%| |**SETUP, RISE TIME**||1500ms, 150ms/277Vac 1500ms, 150ms/230Vac 1500ms, 150ms/115Vac at full load||||| |**HOLD UP TIME (Typ.)**||15ms/277Vac 15ms/230Vac 15ms/115Vac at full load||||| |**INPUT**||||||| |**AC VOLTAGE RANGE**||85 ~305Vac||||| |**DC VOLTAGE RANGE**||80 ~ 431Vdc (Derating50% Load @80Vdc)||||| |**CONSUMPTION(Typ.)**<br>**NO LOAD**|**Remote Power OFF**<br>**Remote Power ON**|1W@115Vac & 230Vac & 277Vac<br>3W@115Vac & 230Vac & 277Vac||||| |**FREQUENCY RANGE**||47 ~ 63Hz||||| |**POWER FACTOR (Typ.)**||PF>0.98/115VacPF>0.95/230Vac<br>at full load<br>PF>90%/277Vac||||| |**EFFICIENCY (Typ.)**||94%|95.5%||95.5%|96%| |**AC CURRENT (Typ.)**||6A/115Vac 3A/230Vac 2.5A/277Vac||||| |**INRUSH CURRENT (Typ.)**||COLD START<br>6A/115Vac 10A/230Vac 15A/277Vac||||| |**LEAKAGE CURRENT**||<1mA / 240Vac <1.5mA / 277Vac||||| |**PROTECTION**||||||| |**OVERLOAD**||105%~200% rated output power for more than 5 sec then<br>at rate current<br> when Vo=30%~100%<br>constant current limiting<br>without shutdown<br>Hiccup mode when Vo<30% rated voltage||||| |**OVER VOLTAGE**||Protection type : Shut down o/p voltage, re-power on to recover<br>30~ 34V<br>57 ~ 66V<br>43 ~ 50V<br>16 ~ 19V||||| |**OVER TEMPERATURE**||Protection type : Shut down o/p voltage, recovers automatically after temperature goes down||||| |**FUNCTION**||||||| |**PARALLEL**||Up to<br>units; Please refer to<br>for more details.<br>1920W (3+1)<br>Function Manual||||| |**DC OK RELAY CONTACT**||Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5A resistive load||||| |**REMOTE CONTROL**||Power ON :RC(Pin9) and 5V_AUX(Pin10) short .<br>Power OFF:RC(Pin9) and 5V_AUX(Pin10) open.||Please refer to<br>for more details.<br>Function Manual||| |**MODBus INTERFACE**||Communication provides functions such as control, setting, and monitoring.||||| |**TRANSIENT PEAK CURRENT CAPABLILTY**||600% rated current for 15ms||||| |**ENVIRONMENT**||||||| |**WORKING TEMP.**||-40 ~ +85℃(Refer to "Derating Curve")||||| |**WORKING HUMIDITY**||20 ~ 95% RH non-condensing||||| |**STORAGE TEMP., HUMIDITY**||-40 ~ +85℃, 10 ~ 95% RH non-condensing||||| |**TEMP. COEFFICIENT**||±0.03%/℃(0 ~ 60℃)||||| |**VIBRATION**||Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||| _File Name:XDR-480-SPEC 2026-01-22_ **- XDR 480 series** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power |**SPECIFICATION**|**XDR-480-36**<br>**XDR-480-24**<br>**XDR-480-12**<br>**XDR-480-48**<br>=Blank, LA, PI|**XDR-480-36**<br>**XDR-480-24**<br>**XDR-480-12**<br>**XDR-480-48**<br>=Blank, LA, PI|**XDR-480-36**<br>**XDR-480-24**<br>**XDR-480-12**<br>**XDR-480-48**<br>=Blank, LA, PI| |---|---|---|---| |**SAFETY & EMC**<br>**Note.4&5&6**|||| |**SAFETY STANDARDS**|CB<br>TUV<br>UL<br>CCC<br>BSMI<br>EAC<br>Marine DNV<br>SEMI F47<br>KC/BIS<br>IEC62368-1, IEC61558-1/-2-16, IEC61010-1/-2-201<br>BS EN/EN62368-1,BS EN/EN61558-1/-2-16,BS EN/EN61010-1/-2-201<br>;UL61010-1/-2-201<br>UL121201/CSA C22.2 NO.213.17 Class I,DIV2 Group A,B,C,D Hazardous Locations T4<br>GB4943.1<br>CNS15598-1<br>TPTC004<br>approved<br>KC62368-1 and BIS IS 13252 (Part 1) certifed, no stock by request ,contact sales for inquires||| |**OVER VOLTAGE CATEGORY**<br>**Note.7**|IEC/EN 61558-1/-2-16 (<br>altitude up to 2000m )<br>OVCⅢ,<br>IEC/EN/UL 61010-1/-2-201 (OVC<br>, altitude up to<br>)<br>Ⅱ<br>000m<br>5<br>IEC/EN 62368-1 (OVC<br>, altitude up to<br>)<br>Ⅱ<br>5000m||| |**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**|IEC/EN 61558-2-16 (<br>SELV)<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1||| |**WITHSTAND VOLTAGE**|I/P-O/P:<br>I/P-FG:<br>O/P-FG: 1.5KVac O/P-DC OK: 0.5KVac<br>4KVac<br>2KVac||| |**EMC EMISSION**<br>**EMC IMMUNITY**<br>**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/ 70%RH||| ||**Parameter**|**Standard**|**Test Level / Note**| ||Conducted|BS EN/EN55032 (CISPR32)/<br>BS EN/EN61204-3 / CNS15936 / KS C 9832|Class B| ||Radiated|BS EN/EN55032 (CISPR32)/<br>BS EN/EN61204-3 / CNS15936 / KS C 9832|Class B| ||Harmonic Current|BS EN/EN61000-3-2|Class A| ||Voltage Flicker|BS EN/EN61000-3-3|-----| ||BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2),KS C 9835,SEMI F47 tested at 200Vac||| ||**Parameter**|**Standard**|**Test Level / Note**| ||ESD|BS EN/EN61000-4-2|Level 4,<br>air ; Level ,<br>contact;<br>15KV<br>4 8KV<br>criteria A| ||Radiated|BS EN/EN61000-4-3|Level 3, 10V/m ; criteria A| ||EFT / Burst|BS EN/EN61000-4-4|Level 4, 4KV ; criteria A| ||Surge|BS EN/EN61000-4-5|Level 4, 2KV/Line-Line ;Level 4,<br>4KV/Line-Line-Chassis ;criteria A| ||Conducted|BS EN/EN61000-4-6|Level 3, 10V ; criteria A| ||Magnetic Field|BS EN/EN61000-4-8|Level 4, 30A/m ; criteria A| |**OTHERS**|||| |**MTBF**|1139.7K hrs min. Telcordia SR-332 (Bellcore); 154.5K hrs min. MIL-HDBK-217F (25℃)||| |**DIMENSION**|**48*125.2*125mm (W*H*D)**||| |**PACKING**|1.1Kg; 12pcs/ 14.2Kg / 1.16CUFT||| |**NOTE**|||| |℃<br>μ μ <br><br><br><br><br><br><br><br><br><br><br><br>℃<br>℃<br><br><br>※:|||| - ℃ - μμ - - - - ℃℃ - ※: _File Name:XDR-480-SPEC 2026-01-22_ ## 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power ## **- XDR 480 series** **==> picture [489 x 644] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram PFC fosc : 80KHz<br>PWM fosc : 65KHz<br>EMI RECTIFIER POWER RECTIFIERS ORING FET +Vo<br>Input FILTER & SWITCHING & -Vo<br>PFC FILTER<br>O.V.P.<br>FG PFC PWM<br>CONTROL CONTROL<br>CURRENT<br>DETECTION<br>O.T.P<br>AUX<br>POWER MCU PARALLEL CS<br>GND<br>RELAY<br>DC OK<br>O.T.P MCU CONTROL<br>TRANSIENT TC<br>PEAK CURRENT GND<br>PHOTO 5V_AUX<br>RECTIFIERS COUPLER<br>& ISOLATION RC<br>FILTER<br>RECTIFIERS DATA D+<br>& ISOLATION D-<br>FILTER<br>Derating Curve<br>Suitable for 100/110/115/120Vac System Suitable for 220/230/240/277Vac System<br>(85~132Vac) (180~305Vac)<br>200<br>Please refer to Function Please refer to Function<br>Manual of peak power Manual of peak power<br>150<br>150<br>120<br>100 100<br>80 80<br>60<br>45<br>30 30<br>-40 -30 0 60 70 85 (VERTICAL) -40 -30 0 60 70 85 (VERTICAL)<br>AMBIENT TEMPERATURE ( ℃ ) AMBIENT TEMPERATURE ( ℃ )<br>Output derating VS input voltage<br>100 100<br>90<br>85 85<br>80<br>70<br>50<br>60<br>50<br>40<br>85 100 115 120 180 220 240 277 305 80 120140 220 240 431<br>INPUT VOLTAGE (Vac) 60Hz INPUT VOLTAGE (Vdc)<br>LOAD (%) LOAD (%)<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:XDR-480-SPEC 2026-01-22_ **-** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 480 series** ## **Peak Power** **==> picture [383 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> Pav = P pk [x] t + PT npk x [(T-t)] ≤ Prated Pav : Average output power�(W)<br>Ppk : Peak output power��(W)<br>t<br>Duty = T x 100% ≤ 35% Pnpk : Non-peak output power(W)<br>t�≤ 5 sec<br>Prated : Rated output power(W)<br>t : Peak power width(sec)<br>P pk T : Period(sec)<br>P av<br>P npk<br>t<br>100Vac<br>T<br>200Vac<br>**----- End of picture text -----**<br> **==> picture [395 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> 40<br>35<br>30<br>25<br>20<br>15<br>10<br>5<br>520W 600W 720W 840W 960W<br>(108%) (125%) (150%) (175%) (200%)<br>Duty(%)<br>**----- End of picture text -----**<br> **Peak output power (W)** **For example (24V model) :** Vin = 200Vac Duty_max = 5% P av= P rated = 480W P pk= 960W t�≤ 5 sec 5 sec T ≥ 5% ≥ 100sec P npk ≤ T PavT-tt P pk P npk[≤] 454.7W _File Name:XDR-480-SPEC 2026-01-22_ **-** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 480 series** ## **Transient peak current Capability** **==> picture [350 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> ※�The power supply can provide transient peak current to support the start-up of inductive or capacitive loads.<br>The maximum duration and voltage dips are explained below.<br>Vo<br>100~132Vac<br>66<br>180~305Vac<br>50<br>40<br>37<br>30<br>25<br>3 XIo 4 XIo 5 XIo 6 XIo<br>Transient peak current voltage dip<br>Vo (%)<br>**----- End of picture text -----**<br> **==> picture [203 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> 100~132Vac 180~305Vac<br>Load Time<br>Vo(%) Vo(%)<br>3xIo 50 66 100ms<br>4xIo 37 50 70ms<br>5xIo 30 40 40ms<br>6xIo 25 25 15ms<br>**----- End of picture text -----**<br> ※�After a transient peak current event occurs, the rated load must be maintained for at least 15 seconds before the next event. **For example : (600% transient peak current)** **==> picture [398 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> 15ms 15ms 15ms<br>6xIo<br>......<br>1xIo<br>0 15s 15s<br>**----- End of picture text -----**<br> _File Name:XDR-480-SPEC 2026-01-22_ **-** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 480 series** ## **Function Manual** |**Pin No.**|**Function**|**Description**| |---|---|---| |||Contact close : PSU turns ON/DC_OK ;| |1,2|DC OK<br>Relay Contact|Contact open : PSU turns OFF/DC_fail;<br>Contact ratings (max.): 30Vdc/1A ,30Vac/0.5A resistive load.| |3|GND|When units are connected in parallel, the GND pins of the units should be connected mutually<br>to allow current balance between units.| |4|CS|Current sharing signal. When units are connected in parallel, the CS pins of the units should<br>be connected mutually to allow current balance between units.| |5|TC (Note.1)|The unit can enable the transient peak current by dry contact between TC(Pin5) and GND(Pin3).<br>Power ON: Short; Power OFF: Open.| |6|D-(Note.2)|Data line used in MODBUS interface| |8|D+ (Note.2)|| |7|GND_AUX|The signal return is isolated from the output terminal. (+Vo & -Vo)| |||The unit can turn the output ON/OFF by electrical signal or dry contact between| |9|RC (Note.2)|RC ON/OFF(Pin9) and 5V_AUX(Pin10).| |||Power ON: Short(4~5Vdc);Power OFF: Open(<0.5Vdc);The Maximum input voltage is 5Vdc.| |10|5V_AUX|For remote control signal only. Isolated from the output terminals.| Note1: Non-isolated signal, referenced to GND. Note2: lsolated signal, referenced to GND-AUX. **==> picture [93 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> +Vo +Vo Vo Vo<br>24V 20A Status<br>Vo Adj.<br>24-29Vdc<br>480W Max.<br>n® ae<br>DC OK DC OK<br>CS GND<br>D- TC<br>5V_AUXD+ RCGND AUX_<br>**----- End of picture text -----**<br> **==> picture [126 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> DC OK 2 1 DC OK<br>CS 4 3 GND<br>D- 6 5 TC<br>D+ 8 7 GND_AUX<br>5V_AUX 10 9 RC<br>**----- End of picture text -----**<br> **==> picture [91 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> - -<br>XDR 480 24<br>**----- End of picture text -----**<br> **==> picture [37 x 17] intentionally omitted <==** **----- Start of picture text -----**<br> 100-277Vac<br>L N<br>**----- End of picture text -----**<br> _File Name:XDR-480-SPEC 2026-01-22_ **- XDR 480 series** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power ## **1.Parallel Use** XDR-480 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : - (1) The transient peak current capability needs to be disabled,The TC pin of the units cannot be connected to GND . - (2) Parallel operation is available by connecting the units shown as below (CS,GND are connected mutually in parallel). - (3) Difference of output voltages among parallel units should be less than 0.2V. - (4) The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9. - (5) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. - (6) The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - (7) When in parallel operation, the minimum output load should be greater than 5% of total output load. - (Min. load >5% rated current per unit x number of unit) - (8) In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition. The other PSUs (slaves) may go into standby mode and their output Green LEDs & relays will not turn on. - (9) CS and GND lines should be twisted in pairs. **==> picture [419 x 213] intentionally omitted <==** **----- Start of picture text -----**<br> Pin : 4 CS Pin 3 : GND<br>+ -<br>LOAD 10 9<br>+Vo<br>-Vo<br>GND<br>CS<br>| fi Ag AL AL<br>1 (peed) +Vo +Vo Tit 2 3 Vo 4 Vo , 1 peed] +Vo +Vo To 2 3 Vo 4 Vo , 1 [peed] +Vo +Vo Co 2 3 Vo 4 Vo o 1 [peed] +Vo +Vo Co 2 3 Vo 4 Vo t<br>Status Status Status Status<br>6 Vo Adj. Vo Adj. Vo Adj. Vo Adj.<br>5V_AUXDC OKDD+CS- E D TCRCDC OKGNDGND AUX_ 5V_AUXDC OKDD+CS- EP TCRCDC OKGNDGND AUX_ 5V_AUXDC OKDD+CS- ED TCRCDC OKGNDGND AUX_ 5V_AUXDC OKDD+CS- EP TCRCDC OKGNDGND AUX_<br>XDR-480 XDR-480 XDR-480 XDR-480<br>PSU1 PSU2 PSU3 PSU4<br> 100-277Vac 100-277Vac 100-277Vac 100-277Vac<br>L N @ L N @ L N @ L N @<br>**----- End of picture text -----**<br> ## **2. Support MODBus Communication** Communication provides functions such as control, setting, and monitoring. Parameters include output voltage, output power, input voltage, etc For details, Please refer to: http://www.meanwell.com/manual.html **==> picture [114 x 38] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1<br>Pin 6 : D- i e<br>Pin 8 : D+ Pin 7 :GND_AUX<br>10 9<br>**----- End of picture text -----**<br> **==> picture [308 x 45] intentionally omitted <==** **----- Start of picture text -----**<br> RS-485 to USB<br>Communication isolation converter To the personal<br>cable computer USB port<br>Personal Computer<br>**----- End of picture text -----**<br> _File Name:XDR-480-SPEC 2026-01-22_ **-** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 480 series** ## **3** . **DC OK Relay Contact** **==> picture [455 x 400] intentionally omitted <==** **----- Start of picture text -----**<br> Contact Close PSU turns ON / DC OK. Pin 2 : DC OK Pin 1 :DC OK<br>Contact Open PSU turns OFF / DC Fail.<br>10 9<br>Contact Ratings (max.) 30Vdc/1A ,30Vac/0.5A resistive load.<br>1<br>R<br>U External voltage source (U) and resistor (R)<br>(The max. Sink is 30Vdc/1A ,30Vac/0.5A)<br>2<br>Internal circuit of DC_OK, via relay contact<br>4.Remote ON/OFF Control<br>The PSU can be turned ON/OFF by using the "Remote Control" function.<br>PSU Vo Status Between RC(Pin9) and 5V_AUX(Pin10) 2 1<br>Remote power ON Short (Pin9=4~5V)<br>Pin 10 : 5V_AUX Pin 9 :RC<br>Remote power OFF Open (Pin9=0~0.5V)<br>Pin 9 User’s Optocoupler 5Vdc(max.) Relay<br>Pin 10 User’s power Pin 9 Pin 9<br>3<br>User’s PSU 2 1 User’s PSU<br>Pin 9 User’s power GND Pin 7 Pin 10<br>Pin 10<br>R.C. by external switch. R.C. by user’s optocoupler control module. auxiliary powerR.C. by user’s external . R.C. by user’s Relay control module.<br>**----- End of picture text -----**<br> ## **4.Remote ON/OFF Control** ## **5.Protection Against Inverse Voltages From The Load** Prevent PSU damage from Back Electro magnetic Force during deceleration of motor or inductive load. **==> picture [203 x 82] intentionally omitted <==** **----- Start of picture text -----**<br> AC + +<br>Io<br>DC<br>DC - -<br>(XDR-480) (DC Load)<br>**----- End of picture text -----**<br> |PSU'S ORing FET turn OFF voltage|PSU'S ORing FET turn OFF voltage|PSU'S ORing FET turn OFF voltage| |---|---|---| |PSU'S ORing FET turn OFF voltage||| |MODEL|Max. allowable reverse voltage|| |XDR-480-12|<16V|| |XDR-480-24|<35V|| |XDR-480-36|<50V|| |XDR-480-48|<63V|| |||| _File Name:XDR-480-SPEC 2026-01-22_ **- XDR 480 series** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power ## **6.LED Status Indictors** ||Output of alarm|Output of alarm| |---|---|---| |Description|Output of alarm|| |Restore Factory Settings|Green : 3 Blink|| |DC OK|Green|| |DC Fail|Red|| |Overload<br>(115Vac: >150% rated current)<br>(230Vac: >200% rated current)|Red : 1 Blink/Pause|| |Over voltage|Red : 2 Blink/Pause|| |Over temperature|Red : 3 Blink/Pause|| |Against Inverse Voltages From The Load|Red : 4 Blink/Pause|| |High Ambient Temperature Warning|Red : Blink|| |Others (Note)|Red : 5 Blink/Pause|| Note: Others include protection status AC UVP、Internal Communication error and EEPROM error. _File Name:XDR-480-SPEC 2026-01-22_ **-** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 480 series** **==> picture [470 x 412] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>(Unit:mm , Tolerance ±1mm) Case No. 303<br>B : Control Pin No. Assignment:JS-2008R-2x05<br> or equivalent<br>Mating Housing Terminal<br>JS-2007-2x05-BK JS-2007-T or<br>or equivalent equivalent<br>Pin No. Assignment<br>1,2 DC OK<br>A : Terminal Pin No.Assignment 3 GND(Current sharing)<br>Pin No. Assignment 4 CS(Current sharing)<br>5 TC<br>1,2 DC Output +Vo<br>6 D-<br>3,4 DC Output -Vo<br>7 GND_AUX<br>8 D+<br>9 RC<br>10 5V_AUX<br>48<br>125<br>1 2 3 4<br>A<br> +Vo +Vo Vo Vo<br>Status<br>Vo Adj.<br>5V_AUXDC OKDD+CS- TCRCDC OKGNDGND AUX_ B<br> 100-277Vac<br>L N<br>C<br>1 2 3<br>125.2<br>**----- End of picture text -----**<br> **==> picture [112 x 49] intentionally omitted <==** **----- Start of picture text -----**<br> C : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1 AC/L or DC Input +Vin<br>2 AC/N or DC Input -Vin<br>3 FG<br>**----- End of picture text -----**<br> _File Name:XDR-480-SPEC 2026-01-22_ **-** 480W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 480 series** ## **Recommend Wiring** **==> picture [252 x 119] intentionally omitted <==** **----- Start of picture text -----**<br> AC Input T.B DC Output T.B<br>Solid Wire 6mm max.2 6mm max.2<br>A.W.G 18~10 AWG 16~10 AWG<br>Blank 10~11mm 10~11mm<br>Wire Stripping Length LA 11~12mm 11~12mm<br>PI 14~15mm 14~15mm<br>Blank 5 Lb-In 5 Lb-In<br>Screw Terminal Torque<br>LA/PI Not applicable<br>**----- End of picture text -----**<br> ## **Accessory List** Communication interface mating wire (standard accessory) **==> picture [429 x 101] intentionally omitted <==** **----- Start of picture text -----**<br> No. Item Quantity<br>50<br>a<br>[a a<br>We!<br>[ [ol] a2 —<br>1 Mating wire UL1007 28AWG 1pcs/per model<br>H20J1-10B<br>or equivalent<br>**----- End of picture text -----**<br> ## **Installation Instruction** **==> picture [300 x 85] intentionally omitted <==** **----- Start of picture text -----**<br> This series fits DIN rail TS35/7.5 or TS35/15.<br>For installation details, please refer to the Instruction manual.<br>ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>35<br>**----- End of picture text -----**<br> ## **Installation Manual** Please refer to : http://www.meanwell.com/manual.html _File Name:XDR-480-SPEC 2026-01-22_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →