- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (25-Jun-2025)
- Product Range: XDR-240E Series
- No. of Outputs: 1 Output
- Output Power Max: 240W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 20A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Laboratory Equipment
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 41.97 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [510 x 799] intentionally omitted <==** **----- Start of picture text -----**<br> 240W AC DC Economical Ultra/ Slim Industrial DIN Rail Power XDR-240E series<br>SE<br>User’s Manual<br>eae neh<br>| — ee<br>—— mW a r<br>xDR-240E-24 IS<br>| 3<br>Moo &<br>|<br>BauarSicherheitbeegelodwacmat geprufto ges g IS13252<br>www.ID 2000000000tuv.com THOMAS SAMUEL THOMAS SAMUEL<br>®<br>LISTED@ BS EN/EN62368-1 4 CBOAg IEC62368-1 AS/NES61558-1 KC62368-1 &<br>UL61010 BS EN/EN61558-1BS EN/EN61010 IEC61558-1IEC61010 AS/NES62368-1 (By request) (By request)<br>© [FAL] [C €] om = | ‘Automate JM Industrial MM Security [MMM Network Jl Telecom<br>CNS15598-1 7 GB4943.1 [«)] @ iM TPTC004 CE Xk Se2O e n<br>(Applying)<br>■ Features ■ Applications<br>* 85~264Vac input with PFC * Industrial control system<br>- Global certificates in multi-fields * Semiconductor fabrication equipment<br>* 40mm slim width - Electro-mechanical apparatus<br>•<br>: High efficiency up to 95.5% and no load power dissipation<1 .2\V Battery charger<br>* Built-in constant current limiting circuit<br>- Protections: Short circuit / Overload / Over voltage<br>/ Over temperature<br>- Fanless design, cooling by free air convection<br>■<br>- Over voltage category Ⅲ (OVC Ⅲ ) GTIN CODE<br>- -40~+70°C wide. range operation. temperature (>+50 ℃ derating); MW Search: https://www.meanwell.com/serviceGTIN.aspx<br>- Operating altitude up to 5000 meters<br>* Built-in DC OK relay contact<br>- Can be installed on DIN rail TS-35/7.5 or 15<br>> 3 years warranty<br>■ Description<br>The XDR-240E series is a 240W AC/DC economical ultra slim industrial DIN rail power. Key features<br>this series include a narrow 40mm casing, optimizing system installation space, and an ultra-wide<br>range of 85~264Vac suitable for global use. It boasts a maximum efficiency of 95.5% and a low<br>power consumption<1.2W for energy savings and carbon reduction. It has built-in constant<br>fanless design, a wide operating temperature range of -40 to +70 ℃ (upto +50 _ ℃ at full load);<br>compliance; built-in DC OK signal. With comprehensive protection functions, complete<br>certifications, and a 3-years warranty, the XDR-240E series is a compact, high-performance, and<br>reliable DIN rail power supply.<br>■ Model Encoding<br>XDR - 240E-|24<br>L e Output voltage(12V/24V/36V/48V)<br>Economical version<br>Output wattage<br>Series name<br>File Name:XDR-240E-SPEC 2025-03-25<br>**----- End of picture text -----**<br> 240W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-240E series** ## **SPECIFICATION** |**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**EMC EMISSION**<br>I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac<br>I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500Vdc/25<br>/ 70%RH<br>℃<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>Class A<br>**Note.4**<br>UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>**OVER VOLTAGE CATEGORY**<br>IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000<br>IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**AC VOLTAGE RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1 00ms, 0ms/230V<br>00ms, 150ms/115V<br>at full load<br>2<br>6<br>ac<br>25<br>ac<br>20<br>ac 20<br>ac<br>ms/230V<br>ms/115V<br>at full load<br>85 ~ 264Vac<br>2<br>ac 1<br>ac<br>.6A/115V<br>3A/230V<br>.<br>COLD START<br>/115V<br>/230V<br>ac<br>ac<br>15A<br>30A<br><1mA / 240Vac<br>Protection type :Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage,recovers automatically after temperature goes down<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note )6**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.)**<br>**Note.2**<br>**VOLTAGE TOLERANCE**<br>**Note.3**<br>**EMC IMMUNITY**<br>**FUNCTION**<br>Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>**POWDR FACTOR (Typ.)**<br>PF>0.95/230V<br>PF>0.98/115V<br>at full load<br>ac<br>ac<br>**XDR-**<br>**0E-12**<br>**24**<br>±2.0%<br>±0.5%<br>±1.0%<br>20A<br>0 ~ 0A<br>2<br>240W<br>100mVp-p<br>12 ~ 1 V<br>5<br>**XDR-**<br>**0E-48**<br>**24**<br>±1.0%<br>±0.5%<br>±1.0%<br>5A<br>0 ~ A<br>5<br>150mVp-p<br>48 ~ 55V<br>**XDR-**<br>**0E-36**<br>**24**<br>±1.0%<br>±0.5%<br>±1.0%<br>6 66<br>.<br>A<br>0 ~ .<br>A<br>6 66<br>1 0mVp-p<br>2<br>36 ~ 42V<br>9 %<br>4<br>Max<br>8<br>. 1 V<br>95. %<br>5<br>Max<br>3<br>. 6 V<br>9 .5%<br>5<br>Max. 50V<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>**Standard**<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>**Test Level / Note**<br>Level 3,<br>air ; Level ,<br>contact; criteria A<br>2<br>8KV<br>4KV<br>Level 3, 10V/m ; criteria A<br>Level , 2KV ; criteria A<br>3<br>Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A<br>Level 3, 10V ; criteria A<br>Level 4, 30A/m ; criteria A<br>**40*125.2*116mm (W*H*D)**<br>1723 2<br>324 4<br>.<br>.<br>K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃<br>**XDR-**<br>**0E-24**<br>**24**<br>±1.0%<br>±0.5%<br>±1.0%<br>10A<br>0 ~ 0A<br>1<br>1 0mVp-p<br>0<br>24 ~ 2 V<br>9<br>9 . %<br>5 2<br>Max<br>5<br>. 3 V<br>℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**DC VOLTAGE RANGE**<br>120 ~ 370Vdc<br>**FREQUENCY RANGE**<br>47 ~ 63Hz<br>12V<br>48V<br>36V<br>24V<br>610<br>16<br>12 2<br>1 27<br>g;<br>pcs/<br>. Kg/ .<br>CUFT<br>**MODEL**<br>**OVERLOAD**<br>**DC OK**<br>**TACT**<br>**RELAY CON**<br>Hiccup mode when output voltage <30%, recovers automatically after fault condition is removed<br>within 30%~100% rated output voltage, recovers automatically after fault condition is removed<br>Constant current limiting without shutdown<br>105~130% rated output power<br>**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>1W@115Vac & 230Vac<br>1.2W@115Vac & 230Vac<br>**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,<br>~~se~~<br>~~GC~~<br>RR~~ee~~<br>**e**s~~GO~~<br>~~G~~<br>~~fe~~<br>O<br>~~se~~<br>~~OC~~<br>~~ee~~<br>es<br>es<br>~~RC~~<br>~~GG~~<br>~~Ct~~<br>es<br>a<br>~~——————~~<br>~~eG~~<br>Rees<br>es<br>es<br>~~ee~~<br>es<br>~~Rf~~<br>a<br>~~ee~~<br>a<br>a<br>a~~RO~~<br>aea<br>eea<br>aea<br>a<br>a<br>aea<br>a<br>a<br>es<br>CR<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|**SAFETY STANDARDS**<br>**WITHSTAND VOLTAGE**<br>**ISOLATION RESISTANCE**<br>**EMC EMISSION**<br>I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac<br>I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500Vdc/25<br>/ 70%RH<br>℃<br>**Parameter**<br>Conducted<br>Radiated<br>Harmonic Current<br>Voltage Flicker<br>**Standard**<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>**Test Level / Note**<br>Class B<br>Class B<br>-----<br>BS EN/EN61000-3-2<br>BS EN/EN61000-3-3<br>Class A<br>**Note.4**<br>UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>**OVER VOLTAGE CATEGORY**<br>IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000<br>IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1<br>**DC VOLTAGE**<br>**RATED CURRENT**<br>**CURRENT RANGE**<br>**RATED POWER**<br>**OUTPUT**<br>**VOLTAGE ADJ. RANGE**<br>**LINE REGULATION**<br>**LOAD REGULATION**<br>**SETUP, RISE TIME**<br>**HOLD UP TIME (Typ.)**<br>**AC VOLTAGE RANGE**<br>**EFFICIENCY (Typ.)**<br>**INPUT**<br>**INRUSH CURRENT (Typ.)**<br>**LEAKAGE CURRENT**<br>**OVER TEMPERATURE**<br>**WORKING TEMP.**<br>**WORKING HUMIDITY**<br>**STORAGE TEMP., HUMIDITY**<br>**TEMP. COEFFICIENT**<br>**VIBRATION**<br>**MTBF**<br>**DIMENSION**<br>**OTHERS**<br>**NOTE**<br>**PACKING**<br>**OVER VOLTAGE**<br>**AC CURRENT (Typ.)**<br>1 00ms, 0ms/230V<br>00ms, 150ms/115V<br>at full load<br>2<br>6<br>ac<br>25<br>ac<br>20<br>ac 20<br>ac<br>ms/230V<br>ms/115V<br>at full load<br>85 ~ 264Vac<br>2<br>ac 1<br>ac<br>.6A/115V<br>3A/230V<br>.<br>COLD START<br>/115V<br>/230V<br>ac<br>ac<br>15A<br>30A<br><1mA / 240Vac<br>Protection type :Hiccup mode, recovers automatically after fault condition is removed<br>Protection type : Shut down o/p voltage,recovers automatically after temperature goes down<br>-40 ~ +70℃(Refer to "Derating Curve")<br>20 ~ 95% RH non-condensing<br>-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃<br>±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)<br>Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>**ENVIRONMENT**<br>**SAFETY &**<br>**EMC**<br>**(Note )6**<br>**PROTECTION**<br>**RIPPLE & NOISE (max.)**<br>**Note.2**<br>**VOLTAGE TOLERANCE**<br>**Note.3**<br>**EMC IMMUNITY**<br>**FUNCTION**<br>Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>**POWDR FACTOR (Typ.)**<br>PF>0.95/230V<br>PF>0.98/115V<br>at full load<br>ac<br>ac<br>**XDR-**<br>**0E-12**<br>**24**<br>±2.0%<br>±0.5%<br>±1.0%<br>20A<br>0 ~ 0A<br>2<br>240W<br>100mVp-p<br>12 ~ 1 V<br>5<br>**XDR-**<br>**0E-48**<br>**24**<br>±1.0%<br>±0.5%<br>±1.0%<br>5A<br>0 ~ A<br>5<br>150mVp-p<br>48 ~ 55V<br>**XDR-**<br>**0E-36**<br>**24**<br>±1.0%<br>±0.5%<br>±1.0%<br>6 66<br>.<br>A<br>0 ~ .<br>A<br>6 66<br>1 0mVp-p<br>2<br>36 ~ 42V<br>9 %<br>4<br>Max<br>8<br>. 1 V<br>95. %<br>5<br>Max<br>3<br>. 6 V<br>9 .5%<br>5<br>Max. 50V<br>**Parameter**<br>ESD<br>Radiated<br>EFT / Burst<br>Surge<br>Conducted<br>Magnetic Field<br>BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>**Standard**<br>BS EN/EN61000-4-2<br>BS EN/EN61000-4-3<br>BS EN/EN61000-4-4<br>BS EN/EN61000-4-5<br>BS EN/EN61000-4-6<br>BS EN/EN61000-4-8<br>**Test Level / Note**<br>Level 3,<br>air ; Level ,<br>contact; criteria A<br>2<br>8KV<br>4KV<br>Level 3, 10V/m ; criteria A<br>Level , 2KV ; criteria A<br>3<br>Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A<br>Level 3, 10V ; criteria A<br>Level 4, 30A/m ; criteria A<br>**40*125.2*116mm (W*H*D)**<br>1723 2<br>324 4<br>.<br>.<br>K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃<br>**XDR-**<br>**0E-24**<br>**24**<br>±1.0%<br>±0.5%<br>±1.0%<br>10A<br>0 ~ 0A<br>1<br>1 0mVp-p<br>0<br>24 ~ 2 V<br>9<br>9 . %<br>5 2<br>Max<br>5<br>. 3 V<br>℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>**DC VOLTAGE RANGE**<br>120 ~ 370Vdc<br>**FREQUENCY RANGE**<br>47 ~ 63Hz<br>12V<br>48V<br>36V<br>24V<br>610<br>16<br>12 2<br>1 27<br>g;<br>pcs/<br>. Kg/ .<br>CUFT<br>**MODEL**<br>**OVERLOAD**<br>**DC OK**<br>**TACT**<br>**RELAY CON**<br>Hiccup mode when output voltage <30%, recovers automatically after fault condition is removed<br>within 30%~100% rated output voltage, recovers automatically after fault condition is removed<br>Constant current limiting without shutdown<br>105~130% rated output power<br>**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>1W@115Vac & 230Vac<br>1.2W@115Vac & 230Vac<br>**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,<br>~~se~~<br>~~GC~~<br>RR~~ee~~<br>**e**s~~GO~~<br>~~G~~<br>~~fe~~<br>O<br>~~se~~<br>~~OC~~<br>~~ee~~<br>es<br>es<br>~~RC~~<br>~~GG~~<br>~~Ct~~<br>es<br>a<br>~~——————~~<br>~~eG~~<br>Rees<br>es<br>es<br>~~ee~~<br>es<br>~~Rf~~<br>a<br>~~ee~~<br>a<br>a<br>a~~RO~~<br>aea<br>eea<br>aea<br>a<br>a<br>aea<br>a<br>a<br>es<br>CR<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|**XDR-**<br>**0E-12**<br>**24**|**XDR-**<br>**0E-12**<br>**24**|**XDR-**<br>**0E-24**<br>**24**|**XDR-**<br>**0E-24**<br>**24**|**XDR-**<br>**0E-36**<br>**24**|**XDR-**<br>**0E-36**<br>**24**|**XDR-**<br>**0E-48**<br>**24**| |---|---|---|---|---|---|---|---|---| ||**DC VOLTAGE**<br>~~GC~~|12V<br>~~se~~<br>~~GC~~||24V<br>~~se~~<br>~~GC~~||36V<br>~~se~~<br>~~GC~~||48V<br>~~se~~<br>~~GC~~| ||**RATED CURRENT**<br>~~GC~~<br>RR|20A<br>~~GC~~<br>||10A<br>~~GC~~<br>||6 66<br>.<br>A<br>~~GC~~<br>||5A<br>~~GC~~<br>| ||**CURRENT RANGE**<br>~~GC~~<br>RR|0 ~ 0A<br>2<br>~~GC~~<br>||0 ~ 0A<br>1<br>~~GC~~<br>||0 ~ .<br>A<br>6 66<br>~~GC~~<br>||0 ~ A<br>5<br>~~GC~~<br>| ||**RATED POWER**<br>RR~~ee~~<br>**e**s|240W<br>~~ee~~<br>~~GO~~||||||| ||**RIPPLE & NOISE (max.)**<br>**Note.2**<br>~~ee~~<br>**e**s|100mVp-p<br>~~ee~~<br>~~GO~~||1 0mVp-p<br>0<br>~~ee~~<br>~~GO~~<br>~~G~~||1 0mVp-p<br>2<br>~~ee~~<br>~~GO~~<br>~~G~~||150mVp-p<br>~~ee~~<br>~~GO~~<br>~~G~~| ||**VOLTAGE ADJ. RANGE**<br>**e**s<br>~~se~~|12 ~ 1 V<br>5<br>~~GO~~<br>~~se~~||24 ~ 2 V<br>9<br>~~GO~~<br>~~G~~<br>O||36 ~ 42V<br>~~GO~~<br>~~G~~<br>O||48 ~ 55V<br>~~GO~~<br>~~G~~| ||**VOLTAGE TOLERANCE**<br>**Note.3**<br>~~fe~~<br>~~se~~<br>~~ee~~|±2.0%<br>~~fe~~<br>~~se~~||±1.0%<br>~~G~~<br>~~fe~~<br>O<br>~~OC~~||±1.0%<br>~~G~~<br>~~fe~~<br>O<br>~~OC~~||±1.0%<br>~~G~~<br>~~fe~~<br>~~OC~~| ||**LINE REGULATION**<br>~~se~~<br>~~ee~~|±0.5%<br>~~se~~||±0.5%<br>O<br>~~OC~~||±0.5%<br>O<br>~~OC~~||±0.5%<br>~~OC~~| ||**LOAD REGULATION**<br>~~se~~<br>~~ee~~|±1.0%<br>~~se~~||±1.0%<br>O<br>~~OC~~||±1.0%<br>O<br>~~OC~~||±1.0%<br>~~OC~~| ||**SETUP, RISE TIME**<br>~~ee~~<br>es|1 00ms, 0ms/230V<br>00ms, 150ms/115V<br>at full load<br>2<br>6<br>ac<br>25<br>ac<br>~~OC~~||||||| ||**HOLD UP TIME (Typ.)**<br>es<br>es|20<br>ac 20<br>ac<br>ms/230V<br>ms/115V<br>at full load||||||| ||**AC VOLTAGE RANGE**<br>es<br>es|85 ~ 264Vac||||||| ||**DC VOLTAGE RANGE**<br>es|120 ~ 370Vdc||||||| ||**N**<br>**(Typ.)**<br>**O LOAD POWER CONSUMPTION**<br>~~RC~~|1W@115Vac & 230Vac<br>~~RC~~||||1.2W@115Vac & 230Vac<br>~~RC~~||| ||**FREQUENCY RANGE**<br>~~RC~~|47 ~ 63Hz<br>~~RC~~||||||| ||**POWDR FACTOR (Typ.)**|PF>0.95/230V<br>PF>0.98/115V<br>at full load<br>ac<br>ac||||||| ||**EFFICIENCY (Typ.)**<br>~~GG~~|9 %<br>4<br>~~GG~~||9 . %<br>5 2<br>~~GG~~||9 .5%<br>5<br>~~GG~~||95. %<br>5<br>~~GG~~| ||**AC CURRENT (Typ.)**<br>~~GG~~<br>~~Ct~~<br>es|2<br>ac 1<br>ac<br>.6A/115V<br>3A/230V<br>.<br>~~GG~~<br>~~Ct~~||||||| ||**INRUSH CURRENT (Typ.)**<br>~~Ct~~<br>es|COLD START<br>/115V<br>/230V<br>ac<br>ac<br>15A<br>30A<br>~~Ct~~||||||| ||**LEAKAGE CURRENT**<br>es<br>a<br>~~——————~~|<1mA / 240Vac<br>~~——————~~||||||| ||**OVERLOAD**<br>a<br>~~——————~~|Hiccup mode when output voltage <30%, recovers automatically after fault condition is removed<br>within 30%~100% rated output voltage, recovers automatically after fault condition is removed<br>Constant current limiting without shutdown<br>105~130% rated output power<br>~~——————~~||||||| ||**OVER VOLTAGE**<br>~~——————~~|Protection type :Hiccup mode, recovers automatically after fault condition is removed<br>Max<br>8<br>. 1 V<br>Max<br>3<br>. 6 V<br>Max. 50V<br>Max<br>5<br>. 3 V<br>~~——————~~||||||| ||**OVER TEMPERATURE**<br>~~——————~~|Protection type : Shut down o/p voltage,recovers automatically after temperature goes down<br>~~——————~~||||||| ||**DC OK**<br>**TACT**<br>**RELAY CON**<br>~~——————~~<br>~~eG~~<br>Re|Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5Aresistive load<br>~~——————~~<br>~~eG~~||||||| ||**WORKING TEMP.**<br>~~eG~~<br>Rees|-40 ~ +70℃(Refer to "Derating Curve")<br>~~eG~~||||||| ||**WORKING HUMIDITY**<br>Rees<br>es|20 ~ 95% RH non-condensing||||||| ||**STORAGE TEMP., HUMIDITY**<br>es<br>es<br>es|-40 ~ +85<br>RH non-condensing<br>, 10 ~ 95%<br>℃||||||| ||**TEMP. COEFFICIENT**<br>es<br>es|±<br>℃<br>℃<br>0.03% /<br>(0 ~ 50<br>)||||||| ||**VIBRATION**<br>es<br>~~ee~~|Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6<br>~~ee~~||||||| ||**SAFETY STANDARDS**|UL61010;<br>BS EN/EN62368-1, BS EN/EN61558-1/-2-16,<br>/<br>; CB IEC62368-1, IEC61558-1,<br>;<br>TUV<br>BS EN EN61010<br>IEC61010<br>EAC TPTC004 approved;KC KC62368-1<br>BIS IS13252 (Part 1):2010 certified no stock ,contact sale for inquires<br>and<br>,<br>RCM<br>AS/NZS 61558-1/-2-16; BSMI CNS1<br>-1; CCC GB4943.1;<br>5598<br>AS/NZS 62368-1,||||||| ||**Note.4**<br>**OVER VOLTAGE CATEGORY**|IEC/EN 61558-1/-2<br>(<br>altitude up to 000<br>)<br>-16<br>2<br>m<br>OVCⅢ,<br>IEC/EN/UL 6<br>(<br>altitude up to<br>)<br>1010<br>OVCⅡ,<br>5000m<br>IEC/EN 62368-1 (<br>altitude up to<br>)<br>OVCⅡ,<br>5<br>m<br>000||||||| ||**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**<br>es|IEC/EN 61558-2<br>(<br>-16<br>SELV )<br>IEC/EN/UL 6<br>(<br>)<br>1010-2-201 SELV<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1||||||| ||**WITHSTAND VOLTAGE**<br>es|I/P-O/P:<br>I/P-FG: 2KV<br>O/P-FG: 1.5KV<br>O/P-DC OK: 0.5KV<br>ac<br>ac<br>ac<br>4KVac||||||| ||**ISOLATION RESISTANCE**<br>**EMC EMISSION**<br>**MTBF**<br>**EMC IMMUNITY**<br>es<br>~~Rf~~<br>a<br>es<br>CR|I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500Vdc/25<br>/ 70%RH<br>℃<br>~~Rf~~||||||| |||**Parameter**<br>~~Rf~~<br>a|**Standard**<br>~~Rf~~||||**Test Level / Note**<br>~~Rf~~|| |||Conducted<br>~~ee~~|BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936<br>~~ee~~||||Class B<br>~~ee~~|| |||Radiated<br>a|BS EN/EN55032 (CISPR32)/ BS EN/EN61204-3 / CNS15936||||Class B|| |||Harmonic Current<br>a<br>a<br>a|BS EN/EN61000-3-2<br>||||Class A<br>|| |||Voltage Flicker<br>a<br>a|BS EN/EN61000-3-3<br>||||-----<br>|| |||BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2)<br>a~~RO~~<br>aea||||||| |||**Parameter**<br>ae<br>ee|**Standard**<br>a<br>a||**Test Level / Note**|||| |||ESD<br>ae<br>ee<br>ae|BS EN/EN61000-4-2<br>a<br>a<br>a||Level 3,<br>air ; Level ,<br>contact; criteria A<br>2<br>8KV<br>4KV|||| |||Radiated<br>ee<br>ae|BS EN/EN61000-4-3<br>a<br>a||Level 3, 10V/m ; criteria A|||| |||EFT / Burst<br>ae<br>a<br>ae|BS EN/EN61000-4-4<br>a<br>a<br>a||Level , 2KV ; criteria A<br>3|||| |||Surge<br>ae|BS EN/EN61000-4-5<br>a||Level 4, 2KV/Line-Line ;Level 4, 4KV/Line-Line-Chassis ;criteria A|||| |||Conducted<br>ae<br>a|BS EN/EN61000-4-6<br>a||Level 3, 10V ; criteria A|||| |||Magnetic Field<br>a<br>a|BS EN/EN61000-4-8||Level 4, 30A/m ; criteria A|||| |||1723 2<br>324 4<br>.<br>.<br>K hrs min.<br>Telcordia SR-332 (Bellcore) ;<br>K hrs min.<br>MIL-HDBK-217F (25<br>)<br>℃||||||| ||**DIMENSION**<br>es<br>CR|**40*125.2*116mm (W*H*D)**||||||| ||**PACKING**<br>℃<br>μ<br>μ<br>F<br>F<br>℃<br>℃<br>(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )<br>※<br>:<br>https://www.meanwell.com/serviceDisclaimer.aspx<br>610<br>16<br>12 2<br>1 27<br>g;<br>pcs/<br>. Kg/ .<br>CUFT<br>CR<br>1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25<br>of ambient temperature.<br>2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1<br>&47<br>parallel capacitor.<br>3. Tolerance: includes setuptolerance, line regulation and load regulation.<br>4. The ambient temperature derating of 3.5<br>/1000m with fanless models and of<br>5<br>/1000m with fan models for operating altitude higher than 2000m(6500ft).<br>5. Installation clearances<br>: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.<br>In case the adjacent device is a heat source, 15mm clearance is recommended.<br>6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets<br>EMC directives.<br>Product Liability Disclaimer<br>For detailed information, please refer to|||||||| **NOTE** EMC directives. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf ) ※ Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx _File Name:XDR-240E-SPEC 2025-03-25_ 240W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-240E series** ## **Block Diagram** **==> picture [465 x 609] intentionally omitted <==** **----- Start of picture text -----**<br> PFCfosc: 65KHz<br>PWM fosc : 70KHz<br>RELAY<br>DC OK<br>CONTROL<br>I/P EMI RECTIFIERS POWER RECTIFIERS +Vo<br>FILTER & PFC SWITCHING & -Vo<br>FILTER<br>PFC O.L.P.<br>CONTROL<br>FG PWM O.V.P.<br>O.T.P. CONTROL<br>DETECTION<br>CIRCUIT<br>Derating Curve<br>100<br>85<br>75<br>50<br>-40 -30 0 10 20 30 40 50 60 70 (VERTICAL)<br>AMBIENTTEMPERATURE( ℃ )<br>Static Characteristics<br>100<br>90<br>85<br>80<br>70<br>60<br>50<br>40<br>85 100 115 120 180 200 220 230 240 264<br>INPUT VOLTAGE (V) 60Hz<br>LOAD (%)<br>LOAD (%)<br>**----- End of picture text -----**<br> _File Name:XDR-240E-SPEC 2025-03-25_ 240W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-240E series** ## **Function Manual** ## **1.DC OK Relay Contact** **==> picture [283 x 481] intentionally omitted <==** **----- Start of picture text -----**<br> Contact Close PSU turns ON / DC OK.<br>Contact Open PSU turns OFF / DC Fail.<br>Contact Ratings (max.) 30Vdc/1A, 30Vac/0.5A resistive load.<br>ee 1 ---<br>R<br>U External voltage source (U) and resistor (R)<br>o | | (The max. Sink is 30Vdc/1A ,30Vac 0 5A/ . )<br>oe 2 Lo<br>Internal circuit of DC_OK, via relay contact<br>+Vo +Vo Vo Vo<br>24V 10A<br>Status<br>Vo<br>24-29Vdc<br>Adj.<br>DC OK DC OK<br>-<br>XDR-240E 24<br>o e r aic<br>eSmR ee eE<br>100-240Vac<br>L N ©<br>**----- End of picture text -----**<br> _File Name:XDR-240E-SPEC 2025-03-25_ 240W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-240E series** **==> picture [459 x 496] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>(Unit:mm , Tolerance ±1mm) Case No.302<br>A : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1,2 DC Output +Vo<br>3,4 DC Output -Vo<br>B : Control Pin No.Assignment<br>Pin No. Assignment<br>1,2 DC OK Relay Contact<br>40<br>116<br>1 2 3 4<br>A<br>+Vo +Vo Vo Vo<br>Status<br>Adj.Vo<br>DC OK 12 B<br>100-240Vac<br>L N<br>C<br>1 2 3<br>C : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1 AC/L or DC Input +Vin<br>2 AC/N or DC Input -Vin<br>3 FG<br>125.2<br>**----- End of picture text -----**<br> |||**Recommend Wiring**|**Recommend Wiring**|**Recommend Wiring**|**Recommend Wiring**|**Recommend Wiring**| |---|---|---|---|---|---|---| |||||||| |||||AC Input T.B|DC Output T.B|Signal connector| |||Solid Wire||6mm max.<br>2|6mm max.<br>2|1.5mm max.<br>2| |||A.W.G|XDR-240E-12<br>XDR-240E-24/36/48|20~10 AWG|14~10 AWG|24~16 AWG| ||||||18~10 AWG|| |||Wire Stripping Length||7~8mm|7~8mm|8~9mm| |||Screw Terminal Torque||5 Lb-In|5 Lb-In|/| _File Name:XDR-240E-SPEC 2025-03-25_ 240W AC DC Economical Ultra/ Slim Industrial DIN Rail Power **XDR-240E series** ## **Installation Instruction** This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 (For reference only. Not included with unit.) ## **InstallationManual** Pleasereferto:http://www.meanwell.com/manual.html _File Name:XDR-240E-SPEC 2025-03-25_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →