Image not available
Illustrative purposes only
XDR-240-48
AC/DC DIN Rail Power Supply (PSU), Screw Terminal, ITE, Industrial & Laboratory Equipment, 1 Output
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: MEAN WELL
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- Product Range: XDR-240 Series
- No. of Outputs: 1 Output
- Output Power Max: 240W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 305V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 48V
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE, Industrial & Laboratory Equipment
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 95.52 € |
| Current stock | 10+ |
| Lead time | 30 days |
**==> picture [438 x 159] intentionally omitted <==** **----- Start of picture text -----**<br> -<br>240W AC/DC High-End Ultra Slim Industrial DIN Rail Power XDR 240 series<br>—<br> <br> <br> <br>**----- End of picture text -----**<br> **==> picture [70 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> <br><br><br>**----- End of picture text -----**<br> **(XDR-240-xx)** **(XDR-240-xxLA)** ## **(XDR-240-xxPI)** Characteristics VerifiedVoltage Sag Immunity **SEMI F47** BauarSicherheitbeegelodwacmat geprufto ges g DNV **www.ID 2000000000tuv.com** DNV.COM/AF **BS EN/EN62368-1 IEC62368-1 (Note.5) BS EN/EN61558-1 IEC61558-1 1 UL61010 BS EN/EN61010 IEC61010 IS 13252** THOMAS SAMUEL THOMAS SAMUEL **By request KC62368-1** k& **CNS15598-1** ~~S©~~ **GB4943** @ . **1** ICE **TPTC004** Xk **( Note.6 ) (By request)** ■ **** ■ **** ‧ ‧ ‧ ‧ ‧ ‧ ‧ V - ‧ - ‧ ‧ - ‧ - ‧ - ‧ ## ■ **** ‧ ‧ https://www.meanwell.com/serviceGTIN.aspx ‧ - ‧Ⅲ Ⅲ - ‧ - ‧ - ‧ - ‧ > ‧ ‧ ‧ - • ‧ ■ **** ℃ ℃ ■ **** ** ** 45 **** ~~TL~~ ee ee ee ee GB _File Name:XDR-240-SPEC 2026-01-22_ ## 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power ## **- XDR 240 series** |**SPECIFICATION**|**SPECIFICATION**|=Blank, LA, PI<br>**XDR-240-36**<br>**XDR-240-24**<br>**XDR-240-12**<br>**XDR-240-48**|=Blank, LA, PI<br>**XDR-240-36**<br>**XDR-240-24**<br>**XDR-240-12**<br>**XDR-240-48**|=Blank, LA, PI<br>**XDR-240-36**<br>**XDR-240-24**<br>**XDR-240-12**<br>**XDR-240-48**|=Blank, LA, PI<br>**XDR-240-36**<br>**XDR-240-24**<br>**XDR-240-12**<br>**XDR-240-48**|=Blank, LA, PI<br>**XDR-240-36**<br>**XDR-240-24**<br>**XDR-240-12**<br>**XDR-240-48**| |---|---|---|---|---|---|---| |**OUTPUT**||||||| |**DC VOLTAGE**||12V|24V||36V|48V| |**LOAD CURRENT RANGE**||0 ~ 20A|0 ~ 10A||0 ~ 6.66A|0 ~ 5A| |**RATED POWER**||240W||||| |**PEAK**|**CURRENT (5sec.)**<br>**POWER (5sec.)**|40A<br>13.32A<br>10A<br>480W(5 sec.)<br>20A||||| |**Note.2**<br>**RIPPLE & NOISE (max.)**||100mVp-p|100mVp-p||120mVp-p|150mVp-p| |**VOLTAGE ADJ. RANGE**||12 ~ 15V|24 ~ 29V||36 ~ 42V|48 ~ 55V| |**Note.3**<br>**VOLTAGE TOLERANCE**||±2.0%|±1.0%||±1.0%|±1.0%| |**LINE REGULATION**||±0.5%|±0.5%||±0.5%|±0.5%| |**LOAD REGULATION**||±1.0%|±1.0%||±1.0%|±1.0%| |**SETUP, RISE TIME**||1500ms, 150ms/277Vac 1500ms, 150ms/230Vac 1500ms, 150ms/115Vac at full load||||| |**HOLD UP TIME (Typ.)**||20ms/277VAC 20ms/230VAC 20ms/115VAC at full load||||| |**INPUT**||||||| |**AC VOLTAGE RANGE**||85 ~305Vac||||| |**DC VOLTAGE RANGE**||80 ~ 431Vdc (Derating50% Load @80Vdc)||||| |**CONSUMPTION(Typ.)**<br>**NO LOAD**|**Remote Power OFF**<br>**Remote Power ON**|1W@115Vac & 230Vac & 277Vac<br>2.5W@115Vac & 230Vac & 277Vac||||| |**FREQUENCY RANGE**||47 ~ 63Hz||||| |**EFFICIENCY (Typ.)**<br>**POWER FACTOR (Typ.)**||PF>0.98/115VacPF>0.95/230Vac PF>0.9/277Vac at full load<br>94%<br>95.5%<br>95.5%<br>95%||||| |**AC CURRENT (Typ.)**||2.6A/115Vac 1.3A/230Vac1.1A/277Vac||||| |**INRUSH CURRENT (Typ.)**||COLD START<br>6A/115Vac 10A/230Vac 15A/277Vac||||| |**LEAKAGE CURRENT**||<1mA / 240Vac <1.3mA/ 277Vac||||| |**PROTECTION**||||||| |**OVERLOAD**||Hiccup mode when Vo<30% rated voltage<br>105%~200% rated output power for more than 5 sec then<br>at rate current<br> when Vo=30%~100%<br>constant current limiting<br>without shutdown||||| |**OVER VOLTAGE**||16 ~ 19V<br>30 ~ 34V<br>57 ~ 66V<br>43 ~ 50V<br>Protection type : Shut down o/p voltage, re-power on to recover||||| |**OVER TEMPERATURE**||Protection type : Shut down o/p voltage, recovers automatically after temperature goes down||||| |**FUNCTION**||||||| |**PARALLEL**||Up to<br>units; Please refer to<br>for more details.<br>960W (3+1)<br>Function Manual||||| |**DC OK RELAY CONTACT**||Relay Contact Ratings (max.):30Vdc/1A, 30Vac/0.5A resistive load||||| |**REMOTE CONTROL**||Power OFF:RC(Pin9) and 5V_AUX(Pin10) open.<br>Power ON :RC(Pin9) and 5V_AUX(Pin10) short .||Please refer to<br>for more details.<br>Function Manual||| |**MODBus INTERFACE**||Communication rovides functions such as control, setting, and monitoring.<br>p||||| |**TRANSIENT PEAK CURRENT CAPABLILTY**||600% rated current for 15ms||||| |**ENVIRONMENT**||||||| |**WORKING TEMP.**||-40 ~ +85℃(Refer to "Derating Curve")||||| |**WORKING HUMIDITY**||20 ~ 95% RH non-condensing||||| |**STORAGE TEMP., HUMIDITY**||-40 ~ +85℃, 10 ~ 95% RH non-condensing||||| |**TEMP. COEFFICIENT**||±0.03%/℃(0 ~ 60℃) on Load output||||| |**VIBRATION**||Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6||||| _File Name:XDR-240-SPEC 2026-01-22_ **- XDR 240 series** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power |**SPECIFICATION**|=Blank, LA, PI<br>**XDR-240-36**<br>**XDR-240-24**<br>**XDR-240-12**<br>**XDR-240-48**|=Blank, LA, PI<br>**XDR-240-36**<br>**XDR-240-24**<br>**XDR-240-12**<br>**XDR-240-48**|=Blank, LA, PI<br>**XDR-240-36**<br>**XDR-240-24**<br>**XDR-240-12**<br>**XDR-240-48**| |---|---|---|---| |**SAFETY & EMC**<br>**Note.4&5&6**|||| |**SAFETY STANDARDS**|CB<br>TUV<br>UL<br>CCC<br>BSMI<br>EAC<br>Marine DNV<br>SEMI F47<br>KC/BIS<br>IEC62368-1, IEC61558-1/-2-16, IEC61010-1/-2-201<br>BS EN/EN62368-1,BS EN/EN61558-1/-2-16,BS EN/EN61010-1/-2-201<br>;UL61010-1/-2-201<br>UL121201/CSA C22.2 NO.213.17 Class I,DIV2 Group A,B,C,D Hazardous Locations T4<br>GB4943.1<br>CNS15598-1<br>TPTC004<br>approved<br>KC62368-1 and BIS IS 13252 (Part 1) certifed, no stock by request ,contact sales for inquires||| |**OVER VOLTAGE CATEGORY**<br>**Note.7**|IEC/EN 61558-1/-2-16 (<br>altitude up to 2000m )<br>OVCⅢ,<br>IEC/EN/UL 61010-1/-2-201 (OVC<br>, altitude up to<br>)<br>Ⅱ<br>000m<br>5<br>IEC/EN 62368-1 (OVC<br>, altitude up to<br>)<br>Ⅱ<br>5000m||| |**SAFETY EXTRA-LOW**<br>**VOLTAGE(SELV)**|IEC/EN 61558-2-16 (<br>SELV)<br>IEC/EN 62368-1 (<br>)<br>SELV / ES1||| |**WITHSTAND VOLTAGE**|I/P-O/P:<br>I/P-FG:<br>O/P-FG: 1.5KVac O/P-DC OK: 0.5KVac<br>4KVac<br>2KVac||| |**EMC EMISSION**<br>**EMC IMMUNITY**<br>**ISOLATION RESISTANCE**|I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC/25℃/ 70%RH||| ||**Parameter**|**Standard**|**Test Level / Note**| ||Conducted|BS EN/EN55032 (CISPR32)/<br>BS EN/EN61204-3 / CNS15936 / KS C 9832|Class B| ||Radiated|BS EN/EN55032 (CISPR32)/<br>BS EN/EN61204-3 / CNS15936 / KS C 9832|Class B| ||Harmonic Current|BS EN/EN61000-3-2|Class A| ||Voltage Flicker|BS EN/EN61000-3-3|-----| ||BS EN/EN55035 , BS EN/EN61204-3, BS EN/EN61000-6-2(BS EN/EN50082-2),KS C 9835,SEMI F47 tested at 200Vac||| ||**Parameter**|**Standard**|**Test Level / Note**| ||ESD|BS EN/EN61000-4-2|Level 4,<br>air ; Level ,<br>contact;<br>15KV<br>4 8KV<br>criteria A| ||Radiated|BS EN/EN61000-4-3|Level 3, 10V/m ; criteria A| ||EFT / Burst|BS EN/EN61000-4-4|Level 4, 4KV ; criteria A| ||Surge|BS EN/EN61000-4-5|Level 4, 2KV/Line-Line ;Level 4,<br>4KV/Line-Line-Chassis ;criteria A| ||Conducted|BS EN/EN61000-4-6|Level 3, 10V ; criteria A| ||Magnetic Field|BS EN/EN61000-4-8|Level 4, 30A/m ; criteria A| |**OTHERS**|||| |**MTBF**|1066.2K hrs min. Telcordia SR-332 (Bellcore); 129.1K hrs min. MIL-HDBK-217F (25℃)||| |**DIMENSION**|**40*125.2*116mm (W*H*D)**||| |**PACKING**|0.79Kg; 16pcs/ 13.6Kg / 1.27CUFT||| |**NOTE**|||| |℃<br>μ μ <br><br><br><br><br><br><br><br><br><br><br><br>℃<br>℃<br><br><br>※:|||| ℃ - μμ - - - ℃℃ ※: _File Name:XDR-240-SPEC 2026-01-22_ **- XDR 240 series** ## 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Block Diagram PFC fosc : 80KHz<br>PWM fosc : 65KHz<br>EMI RECTIFIER POWER RECTIFIERS ORING FET +Vo<br>Input FILTER & SWITCHING & -Vo<br>PFC FILTER<br>O.V.P.<br>FG PFC PWM<br>CONTROL CONTROL<br>CURRENT<br>DETECTION<br>O.T.P<br>AUX<br>POWER MCU PARALLEL CS<br>GND<br>RELAY<br>DC OK<br>O.T.P MCU CONTROL<br>TRANSIENT TC<br>PEAK CURRENT GND<br>PHOTO 5V_AUX<br>RECTIFIERS COUPLER<br>& ISOLATION RC<br>FILTER<br>RECTIFIERS DATA D+<br>& ISOLATION D-<br>FILTER<br>Derating Curve<br>Suitable for 100/110/115/120Vac System Suitable for 220/230/240/277Vac System<br>(85~132Vac) (180~305Vac)<br>150 200<br>Please refer to Function Please refer to Function<br>Manual of peak power Manual of peak power<br>112.5 150<br>100 100<br>80 80<br>75 75<br>45 60<br>30 30<br>-40 -30 0 60 70 85 (VERTICAL) -40 -30 0 60 70 85 (VERTICAL)<br>AMBIENT TEMPERATURE ( ℃ ) AMBIENT TEMPERATURE ( ℃ )<br>Output derating VS input voltage<br>100 100<br>90<br>85 85<br>80<br>70<br>50<br>60<br>50<br>40<br>85 100 115 120 180 220 240 277 305 80 120140 220 240 431<br>INPUT VOLTAGE (Vac) 60Hz INPUT VOLTAGE (Vdc)<br>LOAD (%) LOAD (%)<br>LOAD (%) LOAD (%)<br>**----- End of picture text -----**<br> _File Name:XDR-240-SPEC 2026-01-22_ **-** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 240 series** ## **Peak Power** **==> picture [383 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> Pav = P pk [x] t + PT npk x [(T-t)] ≤ Prated Pav : Average output power�(W)<br>Ppk : Peak output power��(W)<br>t<br>Duty = T x 100% ≤ 35% Pnpk : Non-peak output power(W)<br>t�≤ 5 sec<br>Prated : Rated output power(W)<br>t : Peak power width(sec)<br>T : Period(sec)<br>P pk<br>P av<br>P npk<br>t<br>T<br>**----- End of picture text -----**<br> **==> picture [394 x 204] intentionally omitted <==** **----- Start of picture text -----**<br> 100Vac<br>200Vac<br>40<br>35<br>30<br>25<br>20<br>15<br>10<br>5<br>260W 300W 360W 420W 480W<br>(108%) (125%) (150%) (175%) (200%)<br>Peak output power (W)<br>Duty(%)<br>**----- End of picture text -----**<br> **For example (24V model) :** Vin = 200Vac Duty_max = 5% P av= P rated = 240W P pk= 480W t�≤ 5 sec 5 sec T ≥ 5% ≥ 100sec P npk ≤ T PavT-tt P pk P npk[≤] 227.4W _File Name:XDR-240-SPEC 2026-01-22_ **-** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 240 series** ## **Transient peak current Capability** **==> picture [350 x 194] intentionally omitted <==** **----- Start of picture text -----**<br> ※�The power supply can provide transient peak current to support the start-up of inductive or capacitive loads.<br>The maximum duration and voltage dips are explained below.<br>Vo<br>100~132Vac<br>66<br>180~305Vac<br>50<br>40<br>37<br>30<br>25<br>3 XIo 4 XIo 5 XIo 6 XIo<br>Transient peak current voltage dip<br>Vo (%)<br>**----- End of picture text -----**<br> **==> picture [203 x 78] intentionally omitted <==** **----- Start of picture text -----**<br> 100~132Vac 180~305Vac<br>Load Time<br>Vo(%) Vo(%)<br>3xIo 50 66 100ms<br>4xIo 37 50 70ms<br>5xIo 30 40 40ms<br>6xIo 25 25 15ms<br>**----- End of picture text -----**<br> ※�After a transient peak current event occurs, the rated load must be maintained for at least 15 seconds before the next event. **For example : (600% transient peak current)** **==> picture [398 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> 15ms 15ms 15ms<br>6xIo<br>......<br>1xIo<br>0 15s 15s<br>**----- End of picture text -----**<br> _File Name:XDR-240-SPEC 2026-01-22_ **-** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 240 series** ## **Function Manual** |**Pin No.**|**Function**|**Description**| |---|---|---| |||Contact close : PSU turns ON/DC_OK ;| |1,2|DC OK<br>Relay Contact|Contact open : PSU turns OFF/DC_fail;<br>Contact ratings (max.): 30Vdc/1A ,30Vac/0.5A resistive load.| |3|GND|When units are connected in parallel, the GND pins of the units should be connected mutually<br>to allow current balance between units.| |4|CS|Current sharing signal. When units are connected in parallel, the CS pins of the units should<br>be connected mutually to allow current balance between units.| |5|TC (Note.1)|The unit can enable the transient peak current by dry contact between TC(Pin5) and GND(Pin3).<br>Power ON: Short; Power OFF: Open.| |6|D-(Note.2)|Data line used in MODBUS interface| |8|D+ (Note.2)|| |7|GND_AUX|The signal return is isolated from the output terminal. (+Vo & -Vo)| |||The unit can turn the output ON/OFF by electrical signal or dry contact between| |9|RC (Note.2)|RC ON/OFF(Pin9) and 5V_AUX(Pin10).| |||Power ON: Short(4~5Vdc);Power OFF: Open(<0.5Vdc);The Maximum input voltage is 5Vdc.| |10|5V_AUX|For remote control signal only. Isolated from the output terminals.| Note1: Non-isolated signal, referenced to GND. Note2: lsolated signal, referenced to GND-AUX. **==> picture [315 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> +Vo +Vo Vo Vo<br>24V 10A<br>Status<br>“7 Vo Adj. DC OK 2 1 DC OK<br>24-29Vdc<br>é 240W Max.<br>CS 4 3 GND<br>DC OK DC OK<br>DCS- TCGND D- 6 5 TC<br>5V_AUXD+ RCGND AUX_ D+ 8 7 GND_AUX<br>5V_AUX 10 9 RC<br>**----- End of picture text -----**<br> **==> picture [86 x 13] intentionally omitted <==** **----- Start of picture text -----**<br> - -<br>XDR 240 24<br>**----- End of picture text -----**<br> **==> picture [39 x 18] intentionally omitted <==** **----- Start of picture text -----**<br> 100-277Vac<br>L N<br>**----- End of picture text -----**<br> _File Name:XDR-240-SPEC 2026-01-22_ **- XDR 240 series** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power ~~————e~~ ## **1.Parallel Use** - XDR-240 has the built-in active current sharing function and can be connected in parallel, up to 4 units, to provide higher output power as exhibited below : (1) The transient peak current capability needs to be disabled,The TC pin of the units cannot be connected to GND . - (2) Parallel operation is available by connecting the units shown as below (CS,GND are connected mutually in parallel). - (3) Difference of output voltages among parallel units should be less than 0.2V. - (4) The total output current must not exceed the value determined by the following equation (Output current at parallel operation) =(The rated current per unit) x (Number of unit) x 0.9. - (5) In parallel operation 4 units is the maximum, please consult the manufacture for other applications. - (6) The power supplies should be paralleled using short and large diameter wiring and then connected to the load. - (7) When in parallel operation, the minimum output load should be greater than 5% of total output load. - (Min. load >5% rated current per unit x number of unit) - (8) In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition. The other PSUs (slaves) may go into standby mode and their output Green LEDs & relays will not turn on. - (9) CS and GND lines should be twisted in pairs. **==> picture [409 x 446] intentionally omitted <==** **----- Start of picture text -----**<br> Pin : 4 CS Pin 3 : GND<br>+ - 10 9<br>LOAD<br>+Vo<br>ee -Vo es<br>ee GND<br>CS<br>a ee ee ee<br>a 1 2 3 4 eres 1 2 3 4 ry 1 2 3 4 ao 1 2 3 4<br> +Vo +Vo Vo Vo +Vo +Vo Vo Vo +Vo +Vo Vo Vo +Vo +Vo Vo Vo<br>xe) Status ae) Status xe Status “'O Status<br>Vo Adj. Vo Adj. Vo Adj. Vo Adj.<br>lT e er rr 5V_AUXDC OK ) DD+CS- E D RCDC OKGNDGND AUXTC_ (6066 | 5V_AUXDC OK ) DD+CS- E P TCRCDC OKGNDGND AUX_ | eee | 5V_AUX ) DC OKDD+CS- B P TCRCDC OKGNDGND AUX_ | (eee | 5V_AUXDC OK ) DD+CS- E e RCDC OKGNDGND AUXTC_ |<br>XDR-240 XDR-240 XDR-240 XDR-240<br>PSU1 PSU2 PSU3 PSU4<br> 100-277Vac 100-277Vac 100-277Vac 100-277Vac<br>L N ie) ; L N ie} L N ie) L N ie}<br>1 2 3 1 2 3 1 2 3 1 2 3<br>Communication provides functions such as control, setting, and monitoring. 2 ca) 1<br>Parameters include output voltage, output power, input voltage, etcFor details, Please refer to: http://www.meanwell.com/manual.htmlFor details, Please refer to: http://www.meanwell.com/manual.html Pin 6 : D-Pin 8 : D+ i ma Pin 7 :GND_AUX<br>10 9<br>iee l<br>eS- =<br>| [=a.]<br>RS-485 to USB<br>Communication isolation converter To the personal<br>cable computer USB port<br>Personal Computer<br>**----- End of picture text -----**<br> ## **2. Support MODBus Communication** Communication provides functions such as control, setting, and monitoring. Parameters include output voltage, output power, input voltage, etcFor details, Please refer to: http://www.meanwell.com/manual.htmlFor details, Please refer to: http://www.meanwell.com/manual.html _File Name:XDR-240-SPEC 2026-01-22_ **-** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 240 series** **==> picture [91 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> 3 . DC OK Relay Contact<br>**----- End of picture text -----**<br> **==> picture [455 x 410] intentionally omitted <==** **----- Start of picture text -----**<br> Contact Close PSU turns ON / DC OK. Pin 2 : DC OK Pin 1 :DC OK<br>Contact Open PSU turns OFF / DC Fail.<br>10 9<br>Contact Ratings (max.) 30Vdc/1A ,30Vac/0.5A resistive load.<br>1<br>R<br>U External voltage source (U) and resistor (R)<br>(The max. Sink is 30Vdc/1A ,30Vac/0.5A)<br>2<br>Internal circuit of DC_OK, via relay contact<br>4.Remote ON/OFF Control<br>The PSU can be turned ON/OFF by using the "Remote Control" function.<br>PSU Vo Status Between RC(Pin9) and 5V_AUX(Pin10) 2 1<br>Remote power ON Short (Pin9=4~5V)<br>Pin 10 : 5V_AUX Pin 9 :RC<br>Remote power OFF Open (Pin9=0~0.5V)<br>Pin 9 User’s Optocoupler 5Vdc(max.) Relay<br>Pin 10 User’s power Pin 9 Pin 9<br>3<br>User’s PSU 2 1 User’s PSU<br>Pin 9 User’s power GND Pin 7 Pin 10<br>Pin 10<br>R.C. by external switch. R.C. by user’s optocoupler control module. auxiliary powerR.C. by user’s external . R.C. by user’s Relay control module.<br>**----- End of picture text -----**<br> ## **4.Remote ON/OFF Control** ## **5.Protection Against Inverse Voltages From The Load** Prevent PSU damage from Back Electro magnetic Force during deceleration of motor or inductive load. **==> picture [419 x 111] intentionally omitted <==** **----- Start of picture text -----**<br> AC + + PSU'S ORing FET turn OFF voltage<br>Io MODEL Max. allowable reverse voltage<br>DC<br>XDR-240-12 <16V<br>DC - -<br>XDR-240-24 <35V<br>(XDR-240) (DC Load)<br>XDR-240-36 <50V<br>XDR-240-48 <63V<br>**----- End of picture text -----**<br> _File Name:XDR-240-SPEC 2026-01-22_ **- XDR 240 series** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power ## **6.LED Status Indictors** ||Output of alarm|Output of alarm| |---|---|---| |Description|Output of alarm|| |Restore Factory Settings|Green : 3 Blink|| |DC OK|Green|| |DC Fail|Red|| |Overload<br>(115Vac: >150% rated current)<br>(230Vac: >200% rated current)|Red : 1 Blink/Pause|| |Over voltage|Red : 2 Blink/Pause|| |Over temperature|Red : 3 Blink/Pause|| |Against Inverse Voltages From The Load|Red : 4 Blink/Pause|| |High Ambient Temperature Warning|Red : Blink|| |Others (Note)|Red : 5 Blink/Pause|| Note: Others include protection status AC UVP、Internal Communication error and EEPROM error. _File Name:XDR-240-SPEC 2026-01-22_ **-** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 240 series** **==> picture [511 x 668] intentionally omitted <==** **----- Start of picture text -----**<br> Mechanical Specification<br>(Unit:mm , Tolerance ±1mm) Case No.302<br>B : Control Pin No. Assignment:JS-2008R-2x05<br> or equivalent<br>Mating Housing Terminal<br>JS-2007-2x05-BK JS-2007-T or<br>or equivalent equivalent<br>Pin No. Assignment<br>1,2 DC OK<br>3 GND(Current sharing)<br>4 CS(Current sharing)<br>A : Terminal Pin No.Assignment 5 TC<br>Pin No. Assignment 6 D-<br>1,2 DC Output +Vo 7 GND_AUX<br>3,4 DC Output -Vo 8 D+<br>9 RC<br>40 10 5V_AUX<br>116<br>1 2 3 4<br>A<br> +Vo +Vo Vo Vo<br>Status<br>Vo Adj.<br>5V_AUXDC OKDD+CS- TCRCDC OKGNDGND AUX_ B<br> 100-277Vac<br>L N<br>C<br>1 2 3<br>C : Terminal Pin No.Assignment<br>Pin No. Assignment<br>1 AC/L or DC Input +Vin<br>2 AC/N or DC Input -Vin<br>3 FG<br>125.2<br>**----- End of picture text -----**<br> _File Name:XDR-240-SPEC 2026-01-22_ **-** 240W AC/DC High-End Ultra Slim Industrial DIN Rail Power **XDR 240 series** ## **Recommend Wiring** **==> picture [251 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> AC Input T.B DC Output T.B<br>Solid Wire 6mm max.2 6mm max.2<br>XDR-240-12 14~10 AWG<br>A.W.G 20~10 AWG<br>XDR-240-24/36/48 18~10 AWG<br>Blank 10~11mm 10~11mm<br>Wire Stripping Length LA 11~12mm 11~12mm<br>PI 14~15mm 14~15mm<br>Blank 5 Lb-In 5 Lb-In<br>Screw Terminal Torque<br>LA/PI Not applicable<br>**----- End of picture text -----**<br> ## **Accessory List** Communication interface mating wire (standard accessory) **==> picture [444 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> No. Item Quantity<br>ee<br>50<br>a of<br>a ol<br>a of<br>1 Mating wire H20J1-10B UL1007 28AWG 1pcs/per model<br>or equivalent<br>**----- End of picture text -----**<br> ## **Installation Instruction** **==> picture [432 x 142] intentionally omitted <==** **----- Start of picture text -----**<br> This series fits DIN rail TS35/7.5 or TS35/15.<br>(O LS P p For installation details, please refer to the Instruction manual.<br>eo iT eeeee Le<br>Hh al<br>eal ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15<br>(For reference only. Not included with unit.)<br>AVGcPI|<br>Installation Manual<br>35<br>**----- End of picture text -----**<br> Please refer to : http://www.meanwell.com/manual.html _File Name:XDR-240-SPEC 2026-01-22_
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →