Image not available
Illustrative purposes only
X 222 233 01
Terminal Block, 64mm x 42.5mm x 8.2mm, 6 mm2 Conductor, DIN Rail Mount, 1180 Series Circuit Breakers
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: ETA
- Product type: Circuit Breaker Accessories
- For Use With:1180 Series Circuit Breaker; Accessory Type:Terminal Block; Product Range:-; SVHC:No SVHC (15-Jan-2018); Approval Category:UL; Cross-section Area Max:6mm²; External Depth:64.3mm;
- For Use With: 1180 Series Circuit Breaker
- Product Range: -
- Accessory Type: Terminal Block
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 19.25 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Thermal Overcurrent Circuit Breaker 1180-...** ## **Description** Lo Miniaturised single pole thermal circuit breaker with switching function optional (push-push actuation). Reliable snap-acting and trip-free mechanism. Approved to CBE standard EN/IEC 60934. S-type, TO. Blade terminals fitting into sockets for rail mounting. ## **Typical applications** Protection of loads in power distribution systems in control cabinets and process control. **1180-...** ## **Features and benefits** eee - l Easy mounting due to plug-in design matching standard terminal blocks - l Fine grading of current ratings, particularly in the range of - small ratings ## **Your benefits** - l Space-savings of more than 50 % compared to MCBs - l Significantly higher system availability than provided by fuses thanks to resettability l Rating options selectable for optimum equipment protection - l Very small width of only 8.2 mm l Universally suitable for AC and DC applications ## **Preferred types – for more details on all configurations please see order numbering code** ~~|~~ Preferred types are E-T-A products most frequently used by E-T-A volumes. Our preferred types are supplied at shorter lead times than customers. We manufacture E-T-A preferred types in particularly high non-standard versions. **Preferred types Standard current ratings (A) 0.5 1 1.5 2 2.5 3 4 5 6 8 10** 1180-01x x x x x x x x x x x **Approvals Information online** ~~ee eee~~ The current data sheet is available on our website: www.e-t-a.de/e004 ## **Compliances** Lo **www.e-t-a.de** 2043 1 **Thermal Overcurrent Circuit Breaker 1180-...** ## **Technical data** ## **Technical data** |**Technical data**|**Technical data**| |---|---| |Voltage rating<br>AC 250 V; DC 65 V<br>(UL,UL Canada: AC 250 V;DC 72 V)<br>Current ratings<br>0.1...10 A<br>Typical life<br>6,000 operations at 1 x IN (low-inductance)<br>3,000 operations at 1 x IN(inductive)<br>500 operations at 2 x IN (inductive)<br>Ambient temperature<br>-20...+60 °C(T 60)-4...+140 °F<br>Insulation co-ordination<br>rated impulse<br>pollution<br>(IEC 60664 and 60664 A)<br>withstand voltage<br>degree<br>2.5 kV<br>2<br>reinforced insulation in operatingarea<br>Dielectric strength<br>(IEC 60664 and 60664A) test voltage<br>operating area<br>AC 3,000 V<br>installation area<br>AC 1,500 V<br>Insulation resistance<br>> 100 MΩ(DC 500 V)|Interrupting capacity Icn<br>0,1…5 A<br>6 x IN<br>AC 250 V, DC 65 V<br>6…10 A<br>8 x IN<br>AC 250 V, DC 65 V<br>0,1…0,7 A 25 x IN<br>DC 30 V<br>0,8…6 A<br>10 x IN<br>DC 30 V<br>7…10 A<br>20 x IN<br>DC 30 V| ||Interrupting capacity<br>AC 250 V<br>2,000 A<br>(UL 1077)<br>DC 72 V<br>2,000 A| ||Degree of protection<br>operating area IP40<br>(IEC 60529/DIN 40050)<br>terminal area IP00| ||Vibration<br>5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)<br>without terminal block<br>to IEC 60068-2-6, test Fc,<br>10 frequencycycles/axis and to EN 50155| ||Shock<br>25 g (11 ms)<br>without terminal block<br>to IEC 60068-2-27,test Ea| ||Corrosion 96 hours at 5 % salt mist,<br>to IEC 60068-2-11,test Ka| ||Humidity 240 hours at 95 % RH<br>to IEC 60068-2-78,test Cab| ||Mass approx. 10g| ## **Preferred types** Preferred types are E-T-A products most frequently used by E-T-A customers. We manufacture E-T-A preferred types in particularly high volumes. Our preferred types are supplied at shorter lead times than non-standard versions. |**Preferred types**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**|**Standard current ratings (A)**| |---|---|---|---|---|---|---|---|---|---|---|---| ||**0.5**|**1**|**1.5**|**2**|**2.5**|**3**|**4**|**5**|**6**|**8**|**10**| |1180-01-|x|x|x|x|x|x|x|x|x|x|x| ## **Ordering information** |**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**|**Ordering information**| |---|---|---|---|---|---| |**Type No.**|||||| |**1180**||single pole thermal circuit breaker, plug-in mounting|||| |||**Versions**|||| |||**01**||with switching function, without label|| |||**02**||reset function only, without label|| |||||**Current rating range**|| |||||**0.1...10 A**|| ||||||| **1180 - 01 - 1 A** ordering example ## **Approvals** |**Authority**|**Standard**|**Rated voltage**|**Current ratings**| |---|---|---|---| |VDE|IEC/EN<br>60934|AC 250 V<br>DC 65 V|0.1 A…10 A<br>0.1 A…10 A| |UL|UL 1077<br>C22.2 No 235|AC 250 V / 50/60 Hz<br>DC 72 V|0.1 A…10 A<br>0.1 A…10 A| |CSA|C22.2 No 235|AC 250 V<br>DC 72 V|0.1 A…10 A<br>0.1 A…10 A| |CQC|GB/T17701|AC 250 V,<br>DC 65 V|0,1...10 A| **www.e-t-a.de** 2 2043 **Thermal Overcurrent Circuit Breaker 1180-...** ## **Dimensions** **==> picture [249 x 295] intentionally omitted <==** **----- Start of picture text -----**<br> 24.4<br>.961<br>1.1<br>.043<br>5.2 0.6<br>.205 .024<br>14.5 3.1<br>.571 .122<br>16.6 3.6<br>.654 .142<br>18.2<br>.717<br>19,8<br>.780<br>slot for fitting labels<br>(see accessory 1)<br>2.3°<br>1.91 48.8 1.92 2.06<br>48.6 ON 52.3 OFF<br>8.6 .339<br>1.5 .059<br>8.2 .323<br>6.4 .252<br>1.9 .075<br>8.2 .323<br>**----- End of picture text -----**<br> ## **Internal connection diagram** **==> picture [249 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>2<br>**----- End of picture text -----**<br> ## **Shock directions** **==> picture [249 x 186] intentionally omitted <==** **----- Start of picture text -----**<br> 3<br>2<br>4<br>1<br>label<br>6 Y 307 374 01<br>5<br>current rating<br>1.0A<br>**----- End of picture text -----**<br> ## **Typical time/current characteristics at +23 °C/+73.4 °F** **==> picture [227 x 215] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 0.1 - 5 A<br>6 - 10 A<br>1000<br>100<br>10<br>1<br>0.1<br>1 2 4 6 8 10 20 40<br>… times rated current<br>Trip time in seconds<br>**----- End of picture text -----**<br> The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. ||Ambient temperature °F<br>°C|-4<br>-20|+14<br>-10|+32<br>0|+73,4<br>+23|+104<br>+40|122<br>+50|+140<br>+60| |---|---|---|---|---|---|---|---|---| ||Derating factor|0.76|0.84|0.92|1|1.08|1.16|1.24| **Note:** When several devices are mounted together, each device should only carry 80 % of its rating or it must be overrated accordingly. ## **Standard current ratings and typical internal resistance values** |**Current**<br>**rating (A)**|**Internal**<br>**resistance (Ω)**|**Current**<br>**rating (A)**|**Internal**<br>**resistance (Ω)**| |---|---|---|---| |0.1|81|2|0.25| |0.2|22|2.5|0.18| |0.25|14|3|0.11| |0.3|8.7|3.5|0.08| |0.4|5.5|4|0.07| |0.5|3.4|5|≤ 0.05| |0.6|2.5|6|≤ 0.05| |0.7|1.7|7|≤ 0.05| |0.8|1.5|8|≤ 0.05| |1|0.9|10|≤ 0.05| |1.5|0.4||| This is a metric design and millimeter dimensions take precedence ~~(~~[mm ] inch ~~)~~ **www.e-t-a.de** 2043 3 **Thermal Overcurrent Circuit Breaker 1180-...** ## **Accessories - Terminal block with screw terminals** ~~eee~~ **==> picture [195 x 134] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions X 222 233 02<br>8<br>.315<br>64.3<br>LED 2.53<br>833.. 1.33 36.4 1.43<br>42.7 1.68<br>**----- End of picture text -----**<br> **==> picture [440 x 272] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>@ 3<br>4 8<br>.315<br>+ grace 64.3<br>LED 2.53<br>H 5<br>M<br>4<br>Vibration with terminal block X 222 233 01 and<br>e 6 X 222 233 02<br>5 g (57-500 Hz), ± 0.38 mm (10-57 Hz) to IEC<br>60068-2-6, test Fc, 10 frequency cycles/axis and<br>EN 50155<br>Shock with terminal block X 222 233 01 and<br>® 2 X 222 233 02<br>z 25 g (11 ms)<br>to IEC 60068-2-27, test Ea<br>@ 3<br>33.833.. 1.33 36.4 1.43<br>42.7 1.68<br>**----- End of picture text -----**<br> - **1 Label** for circuit breaker 1180, surface for marking 4.5 x 5 mm (packaging quantity 120 pcs) **Y 307 374 01** - **2 Terminal block** for DIN rail mounting, with screw terminals up to 6 mm[2] conductor, width 8.2 mm, dimensions 64 x 42.5 x 8.2 mm, - headroom over the upper rail edge with circuit breaker fitted (OFF position) 84 mm. Approvals: UL File E197598 **X 222 233 01** - **3 Terminal block** for DIN rail mounting see item 2, but with LED DC 24 V (lighted after tripping); current rating LED 2 mA - Approvals: UL File E197598 - **X 222 233 02** - **4 Bus connection** for potential bridging of several terminal blocks see item 2 and 3 (10-pole, separable, mounting hardware included), max. current rating 34 A - **X 222 232 01** - **5 Insulation barriers** for insertion between two circuits (packaging quantity 10 pcs) - **Y 307 373 01** - **6 Label** for terminal block, see item 2 and 3, surface for marking 8 x 10 mm (packaging quantity 10 pcs) **Y 307 375 01** inch This is a metric design and millimeter dimensions take precedence ~~(~~[mm ] ~~)~~ 4 **www.e-t-a.de** 2043 ~~ee~~ **Thermal Overcurrent Circuit Breaker 1180-...** ## **Accessories - Terminal block with spring-loaded terminals** Lo **==> picture [140 x 240] intentionally omitted <==** **----- Start of picture text -----**<br> 1<br>9<br>e@<br>10<br>13<br>><br>7<br>8<br>@ 11<br>@ 12<br>**----- End of picture text -----**<br> - **1 Label** for circuit breaker 1180, surface for marking 4.5 x 5 mm (packaging quantity 120 pcs) **Y 307 374 01** **==> picture [101 x 137] intentionally omitted <==** **----- Start of picture text -----**<br> Dimensions X 222 316 01<br>6<br>86.5<br>3.41<br>42.2 1.66<br>8.2 .323<br>**----- End of picture text -----**<br> |**Vibration**<br>**with terminal blocks X 222 316 01**<br>**and X 222 315 02**<br>vibration axis 3-4:<br>3 g (57-500 Hz), ± 0.38 mm (10-57 Hz)<br>other axes:<br>5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)<br>to IEC 60068-2-6, test Fc, 10 frequency cycles/axis<br>and EN 50155|**with terminal blocks X 222 316 01**<br>**and X 222 315 02**<br>vibration axis 3-4:<br>3 g (57-500 Hz), ± 0.38 mm (10-57 Hz)<br>other axes:<br>5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)<br>to IEC 60068-2-6, test Fc, 10 frequency cycles/axis<br>and EN 50155| |---|---| |**Shock**<br>**with terminal blocks X 222 316 01**<br>**and X 222 315 02**<br>25 g (11 ms)<br>to IEC 60068-2-27, test Ea|**with terminal blocks X 222 316 01**<br>**and X 222 315 02**<br>25 g (11 ms)<br>to IEC 60068-2-27, test Ea| - **7 Terminal block** for DIN rail mounting, with spring-loaded terminals up to 4 mm[2] conductor, width 8.2 mm, dimensions 68.5 x 36.5 x 8.2 mm, headroom over the upper rail edge with circuit breaker fitted (OFF position) 82 mm. Approvals: UL File E197598 **X 222 316 01** - **8 Terminal block** for DIN rail mounting see item 7, but with LED DC 24 V (lighted after tripping); current rating LED 2 mA Approvals: UL File E197598 **X 222 315 02** - **9 Jumper 2pole,** max. current rating 32 A for terminal blocks items 7 and 8 and feed supply terminal item 11. **X 222 318 01** - **10 Jumper 3pole,** max. current rating 32 A for terminal blocks items 7 and 8 and feed supply terminal item 11. **X 222 318 02** - **11 Feed supply terminal** with spring-loaded terminals up to 6 mm[2 ] conductor, width 8.2 mm, suitable for use with jumpers items 9 and 10 (power distribution). **X 222 317 01** - **12 Cover** for feed supply terminal item 11 for closing the open side at the end of an assembly. **Y 307 507 01** - **13 Label** for terminal block items 7 and 8, and feed supply terminal item 11, surface for marking 7.5 x 5 mm (packaging quantity 50 pcs) **Y 307 508 01** This is a metric design and millimeter dimensions take precedence ~~(~~[mm ] inch ~~)~~ All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. **www.e-t-a.de** 2043 5
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →