Image not available
Illustrative purposes only
WM1296AV53CS
DIGITAL PANEL INSTRUMENTATION
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CARLO GAVAZZI / PARTNER STOCK
- Product type: Digital Panel Meters
- SVHC: No SVHC (21-Jan-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 429.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Energy Management Multifunction indicator Type WM12-96** - **Accuracy ±0.5 F.S. (current/voltage)** - **Multifunction indicator** - **Display of instantaneous variables: 3x3 digit** - **Variable system and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Hz** - **Amax, Wdmd max indication** - **TRMS meas. of distorted sine waves (voltages/currents)** - **Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC** - **Protection degree (front): IP65** - **Front dimensions: 96x96mm** - **Optional RS422/485 serial output** - **Alarms (visual only) VLN, An** **Product Description How to order WM12-96 AV5 3 D XX** 3-phase multifunction power Housing for panel mounting, **Model** indicator with built-in pro(front) protection degree IP65 **Range code** gramming key-pad. Particuas standard, and optional **System** larly recommended for disRS485 serial output. **Power supply** playing the main electrical ~~i~~ **Option** variables. ## **T e Selection yp** |**Type Selection**||| |---|---|---| |**Range codes**|**System**|| |**AV5:**<br>380/660VL-L/5(6)AAC<br>VL-N: 185 V to 460 V<br>VL-L: 320 V to 800 V<br>**AV6:**<br>120/208VL-L/5(6)AAC|**3 :**|1-2-3-phase,<br>unbalanced load,<br>with or without<br>neutral| |VL-N: 45 V to 145 V||| |VL-L: 78 V to 250 V||| |Phase current: 0.03A to 6A||| |Neutral current: 0.09 to 6A||| ## **In ut s ecifications p p** |**Rated inputs**|| |---|---| |Current|3 (shunt)| |Voltage|4| |**Accuracy** (display, RS485)<br>(@25°C ±5°C, R.H.≤60%)|with CT=1 and VT=1 AV5:<br>1150W-VA-var, FS:230VLN,<br>400VLL; AV6: 285W-VA-var,<br>FS:57VLN, 100VLL| |Current<br>Neutral current|0.25 to 6A: ±(0.5% FS +1DGT)<br>0.03A to 0.25A: ±7DGT<br>0.25 to 6A: ±(1.5% FS +1DGT)<br>0.09A to 0.25A: ±7DGT| |Phase-phase voltage|±(1.5%FS +1 DGT)| |Phase-neutral voltage|±(0.5% FS + 1 DGT)| |Active and Apparent power,<br>Power factor|0.25 to 6A: ±(1% FS +1DGT);<br>0.03A to 0.25A: ±(1% FS<br>+5DGT)| |Reactive power|0.25 to 6A: ±(2% FS +1DGT);| |Frequency|0.03A to 0.25A: ±(2% FS<br>+5DGT)<br>±0.1%Hz(48 to 62Hz)| |**Additional errors**|| |Humidity|≤0.3% FS,60% to 90% RH| |**Temperature drift**|≤200ppm/°C| |**Power supply**|**Options**| |---|---| |**A:**<br>24VAC|**X:**<br>None| |-15+10%, 50-60Hz|**S:**<br>RS485 output| |**B:**<br>48VAC|| |-15+10%, 50-60Hz|| |**C:**<br>115VAC|| |-15+10%, 50-60Hz|| |**D:**<br>230VAC|| |-15+10%, 50-60Hz|| |**3:**<br>18 to 60VDC|| |**Sampling rate**|1400 samples/s @ 50Hz| ||1700 samples/s @ 60Hz| |**Display refresh time**|700ms| |**Display**|| |Type|LED, 14mm| |Read-out for the instant. var.|3x3 DGT| |**Measurements**|Current, voltage, power,| ||power factor, frequency| ||TRMS measurement of| ||distorted waves.| |Coupling type|Direct| |Crest factor|< 3,max 10Apeak| |**Input impedance**|| |380/660VL-L(AV5)|1 MΩ±5%| |120/208VL-L(AV6)|453 KΩ±5%| |Current|≤0.02Ω| |**Frequency**|48 to 62 Hz| |**Overload protection**|| |Continuous voltage/current|1.2 F.S.| |For 500ms: voltage/current|2 Un/36A| **1** Specifications are subject to change without notice WM12 96 DS ENG 170408 **WM12-96** ## **RS485 Serial Output Specifications** **RS422/RS485** (on request) Type Multidrop bidirectional (static and dynamic variables) Connections 2 or 4 wires, max. distance 1200m, termination directly on the instrument Addresses 1 to 255, key-pad selectable Protocol MODBUS/JBUS ## Data (bidirectional) Dynamic (reading only) Static (writing only) Data format Baud-rate System and phase variables All configuration parameters 1 bit di start , 8 data bit, no parity, 1 stop bit 9600 bit/s ## **Software functions** |**Password**<br>Numeric code of max. 3<br>digits; 2 protection levels<br>of the programming data<br>1st level<br>Password “0”, no<br>protection<br>2nd level<br>Password from 1 to 999,<br>all data areprotected<br>**System selection**<br>3-phase with neutral<br>3-phase without neutral<br>3-phase ARON<br>2-phase<br>Singlephase<br>**Transformer ratio**<br>CT<br>1 to 999<br>VT<br>1.0 to 99.9<br>**Filter**<br>Operating range<br>0 to 99.9% of the input<br>electrical scale<br>Filtering coefficient<br>1 to 16<br>Filter action<br>Measurements, alarms,<br>serial output<br>(fundamental variables: V, A,<br>W and their derived ones).|**Displaying**<br>Up to 3 variables per page<br>3-phase system with neutral<br>Page 1:V L1, V L2, V L3<br>Page 2: V L12, V L23, V L31<br>Page 3:A L1, A L2, A L3<br>Page 4: An<br>Page 5: W L1, W L2, W L3<br>Page 6: PF L1, PF L2,<br>PF L3<br>Page 7: var L1, var L2, var L3<br>Page 8: VA L1, VA L2, VA L3<br>Page 9: VA∑, W∑, var∑<br>Page 10: VA dmd, W dmd,<br>Hz<br>Page 11: Wdmd MAX<br>Page 12: VL-L∑, PF∑<br>Page 13: A MAX| |---|---| ||**Alarms**<br>Programmable, for the VL∑and<br>An (neutral current).<br>Note: the alarm is only visual,<br>by means of LED on the front<br>of the instrument.| ||**Reset**<br>Independent<br>alarm (VL∑, An)<br>max: A, Wdmd| ## **Power Su l S ecifications pp y p** **Auxiliary power supply** 230VAC 24VAC -15 +10%, 50-60Hz -15 +10%, 50-60Hz 115VAC 18 to 60VDC -15 +10%, 50-60Hz **Power consumption** AC: 4.5 VA 48VAC DC: 4W -15 +10%, 50-60Hz ## **General S ecifications p** |**Operating**<br>-5 to +50°C (23 to 122°F)<br>**temperature**<br>(RH < 90% non condensing at<br>40°C)<br>**Storage**<br>-30 to +60°C (-22 to 140°F)<br>**temperature**<br>(RH < 90% non condensing at<br>40°C)<br>**Installation category**<br>Cat. III(IEC 60664,EN60664)<br>**Insulation**(for 1 minute)<br>4000VAC, 500VDC<br>between measuring<br>inputs and power supply.|500VAC/DC between<br>measuring inputs and<br>RS485.<br>4000VAC, 500VDC between<br>power supplyand RS485<br>**Dielectric strength**<br>4000 VAC(for 1 min)<br>**EMC**<br>Emissions<br>EN50084-1 (class A)<br>residential environment,| |---|---| **2** Specifications are subject to change without notice WM12 96 DS ENG 170408 **WM12-96** ## **General Specifications (cont.)** ||commerce and light industry| |---|---| |Immunity<br>**Pulse voltage (1.2/50µs)**<br>**Safety standards**<br>**Approvals**|EN61000-6-2 (class A)<br>industrial environment.<br>EN61000-4-5<br>IEC60664,EN60664<br>CE,UL,CSA| |**Connections 5(6) A**|Screw-type| |Max cable cross sect. area|2.5 mm2| |**Housing**|| |Dimensions (WxHxD)|96 x 96 x 63 mm| |---|---| |Material|ABS| ||self-extinguishing: UL 94 V-0| |**Mounting**|Panel| |**Protection degree**|Front: IP65 (standard),| ||NEMA4x, NEMA12| ||Connections: IP20| |**Weight**|Approx. 400 g (pack. incl.)| ## **Waveform of the signals that can be measured** **Figure A Sine wave, undistorted** Fundamental content 100% Harmonic content 0% Arms = 1.1107 | A | **Figure B Sine wave, indented** Fundamental content 10...100% Harmonic content 0...90% Frequency spectrum: 3rd to 16th harmonic Additional error: <1% FS **Figure C Sine wave, distorted** Fundamental content 70...90% Harmonic content 10...30% Frequency spectrum: 3rd to 16th harmonic Additional error: <0.5% FS ## **Display pages** **Display variables in 3-phase systems (in a 3-phase system with neutral)** |**No**|**1st variable**<br>~~ee~~|**2nd variable**<br>~~ee~~|**3rd variable**|**Note**| |---|---|---|---|---| |1|V L1<br>~~ee~~|V L2<br>~~ee~~|V L3<br>~~ee~~|| |2|V L12|V L23|V L31|Decimal point blinking on the right<br>of the display| |3|A L1<br>~~a~~|A L2|A L3|| |4|An|AL.n||AL.n if neutral current alarm is<br>active| |5|W L1|W L2|W L3|Decimal point blinking on the right<br>of the displayifgeneratedpower| |6|PF L1<br>~~es~~|PF L2<br>~~es~~|PF L3<br>~~es~~|| |7|VAR L1|VAR L2|VAR L3|Decimal point blinking on the right<br>of the displayifgeneratedpower| |8|VA L1<br>~~es~~|VA L2<br>~~es~~|VA L3<br>~~es~~|| |9|VA system<br>~~pp~~|W system<br>~~pp~~|VAR system<br>~~pp~~|| |10|VA dmd<br>(system)|W dmd<br>(system)|Hz<br>(system)|dmd = demand (integration time<br>selectable from 1 to 30 minutes)| |11|~~pf~~|W dmd MAX<br>~~pf~~|~~pf~~|Maximum syspower demand| |12|V LL system|AL.U|PF system|AL.U= is activated only if one of<br>VLN is not within the set limits| |13|A MAX|~~po~~||max. current amongthe threephases| **3** Specifications are subject to change without notice WM12 96 DS ENG 170408 **WM12-96** ## **Used calculation formulas** ## **Phase variables** **Phase variables** Instantaneous apparent power Instantaneous effective voltage Yn = ft Bivl?= Instantaneous reactive power VA, = Vin‘ Ay Instantaneous active power W,= n VAT, = |(VA )? —(W,)? i ‘E(Vinb (Ay); **System variables** ‘ , Instantaneous power factor Equivalent 3-phase voltage sevnaay cost,= weewy Instantaneous effective current 3-phase reactive power 3-phase active power W,=W,+W2+Ws5 3-phase apparent power VA, = jw 24 VAr,2 3-phase power factor x ® > W; cose:= yam Neutral current z **An = AL1 + AL2 + AL3** **F1** = 315mA ## **Wiring diagrams** **==> picture [493 x 359] intentionally omitted <==** **----- Start of picture text -----**<br> Fig. 1 Fig. 2 Fig. 3<br>17 19 21 15 24 23 26 25 28 27 17 19 21 15 24 23 26 25 28 27 17 19 21 24 23 26 25<br>F1<br>L1 L1 L1<br>L2 L2 L2<br>L3 L3 L3<br>N N<br>CT connection 3CT and 3VT connection ARON connection<br>Fig. 4 Fig. 5 RS485 serial connection Fig. 6<br>Gh EAD ri<br>17 19 15 24 23 26 25 17 15 24 23 ++-—Ix+<br>a<br>F1 F1 ee ie<br>L1 L1<br>L2 L2 [1] [2] [3]<br>L3<br>N N<br>1-Last instrument<br>2-1...n Instrument<br>3-SIU-PC<br>ARON and VT connection 2-phase connection 4-wire connection<br>**----- End of picture text -----**<br> **NOTE:** the current inputs can be connected to the lines ONLY by means of current transformers. The direct connection is not allowed. **ATTENTION:** Only one ammeter input can be connected to earth, as shown in the electrical diagrams. **4** Specifications are subject to change without notice WM12 96 DS ENG 170408 **WM12-96** **Front Panel Descri tion p** ~~ns~~ **1. Key-pad** To program the configuration parameters and the display of the variables. 2 **S** Key to enter programming and confirm selections; L Keys to: - programme values; - select functions; - display measuring pages. **2. Display** 1 LED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. ~~a~~ ## **Dimensions and Panel Cut-out** **==> picture [317 x 241] intentionally omitted <==** **----- Start of picture text -----**<br> 96mm 15.4mm<br>Oo=a | NX<br>61.4mm<br>91mm<br>96mm 96mm<br>**----- End of picture text -----**<br> **5** Specifications are subject to change without notice WM12 96 DS ENG 170408
Updated at June 9, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →