WLB32PEX285QP
DISTANCE SENSORS
- Manufacturer: BANNER ENGINEERING
- Product type:
- SVHC: No SVHC (15-Jan-2018)
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 217.5 € |
| Current stock | 10+ |
| Lead time | 30 days |
## WLB32 Industrial Pro PoE LED Light Product Manual **==> picture [464 x 368] intentionally omitted <==** Original Instructions p/n: 247509 Rev. A 18-Mar-25 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com WLB32 Industrial Pro PoE LED Light Product Manual ## Contents **Chapter 1 Features.................................................................................................................. 3** Models ........................................................................................................................................................................................................... 3 **Chapter 2 Wiring...................................................................................................................... 4 Chapter 3 Modbus TCP/IP Register Map............................................................................... 5 Chapter 4 Specifications ........................................................................................................ 7** FCC Part 15 Class B for Unintentional Radiators.......................................................................................................................................... 8 Industry Canada ICES-003(B)....................................................................................................................................................................... 8 Dimensions.................................................................................................................................................................................................... 8 Light Characteristics...................................................................................................................................................................................... 9 **Chapter 5 Accessories.......................................................................................................... 12** Cordsets ...................................................................................................................................................................................................... 12 Mounting Brackets....................................................................................................................................................................................... 12 **Chapter 6 Product Support and Maintenance .................................................................... 14** Clean with Mild Detergent and Water.......................................................................................................................................................... 14 Repairs ........................................................................................................................................................................................................ 14 Contact Us................................................................................................................................................................................................... 14 Banner Engineering Corp Limited Warranty................................................................................................................................................ 14 Mexican Importer......................................................................................................................................................................................... 14 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com WLB32 Industrial Pro PoE LED Light Product Manual ## Chapter Contents Models.................................................................................................................................................................................................................. 3 ## Chapter 1 ## Features Banner’s WLB32 is an ultra-bright LED fixture with an even light output for a no-glare ‘glow’. Suitable for a variety of environments and applications, including workstations, machine lighting, control cabinets, and manufacturing lines, the WLB32 uses advanced LED lighting technology to provide a high-quality and maintenance-free industrial lighting solution for years. - Cost-effective luminaire for use when AC power or a DC power supply are not available - Connect directly to a Power over Ethernet (PoE) enabled port on a managed or unmanaged Ethernet switch - Control intensity and flashing animations with Modbus TCP/IP communication - 285 mm and 570 mm models compliant with PoE (Class 0 - 802.3af, 802.3at Type 1) hardware negotiation - 850 mm and 1130 mm models compliant with PoE+ (Class 4 - 802.3at Type 2) hardware negotiation - Metal housing, shatterproof window - Easy installation with snap clips included IMPORTANT: Read the following instructions before operating the light. Please download the complete WLB32 Industrial Pro PoE LED Light technical documentation, available in multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions of this device. IMPORTANT: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde www.bannerengineering.com toda la documentación técnica de los WLB32 Industrial Pro PoE LED Light, disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las instrucciones de instalación de estos dispositivos. IMPORTANT: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation technique complète des WLB32 Industrial Pro PoE LED Light sur notre site www.bannerengineering.com pour les détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage. ## Models **==> picture [470 x 145] intentionally omitted <==** **----- Start of picture text -----**<br> Lighted Length<br>Models Window Connector Lumens<br>(mm)<br>WLB32PEX285QP 285 750<br>WLB32PEX570QP 570 1500<br>Standard<br>WLB32PEX850QP 850 2250<br>WLB32PEX1130QP 1130 475 mm (18.7 in) PVC-jacketed cable with 3000<br>a 4-pin D-Code M12 female quick-<br>WLB32PEX285EQP 285 disconnect connector 750<br>WLB32PEX570EQP 570 1500<br>Eye Shield<br>WLB32PEX850EQP 850 2250<br>WLB32PEX1130EQP 1130 3000<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 3 of 15 18-Mar-25 WLB32 Industrial Pro PoE LED Light Product Manual ## Chapter Contents ## Chapter 2 ## Wiring **==> picture [472 x 80] intentionally omitted <==** **----- Start of picture text -----**<br> Pinout Pin Connection (802.3af mode A, mixed DC and data)<br>475 mm (18.7 in) cable with 4-pin D-Code M12 Female Quick-Disconnect 1 TX+ / DC-<br>Connector<br>2 RX+ / DC+<br>4<br>3 TX- / DC-<br>3 1<br>4 RX- / DC+<br>| 2<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 4 of 15 18-Mar-25 WLB32 Industrial Pro PoE LED Light Product Manual ## Chapter Contents ## Chapter 3 ## Modbus TCP/IP Register Map ## Holding Registers to Configure Run Mode **==> picture [500 x 302] intentionally omitted <==** **----- Start of picture text -----**<br> Address without Offset Address with Offset Description Holding Register Representation Default Value Saved Access<br>0 = Off<br>1 = Steady<br>3300 3301 Animation 1 Yes RW<br>2 = Flash<br>3 = Intensity Sweep<br>0 = High<br>1 = Medium<br>3301 3302 Light Intensity 2 = Low 0 Yes RW<br>3 = Off<br>4 = Custom<br>0 = Standard<br>1 = Slow<br>3302 3303 Flash Speed 0 Yes RW<br>2 = Fast<br>3 = Custom Flash Rate<br>0 = Normal<br>1 = Strobe<br>3303 3304 Flash Pattern 2 = Reserved 0 Yes RW<br>3 = Reserved<br>4 = Random<br>**----- End of picture text -----**<br> ## Holding Registers to Configure Custom Settings **==> picture [500 x 55] intentionally omitted <==** **----- Start of picture text -----**<br> Address without Offset Address with Offset Description Holding Register Representation Default Value Saved Access<br>3400 3401 Custom Intensity (%) 10-100 100 Yes RW<br>3401 3402 Custom Speed (dHz) 5-255 15 Yes RW<br>**----- End of picture text -----**<br> ## Holding Registers to Configure Ethernet Communication **==> picture [500 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> Setting Value<br>Server Port 502<br>Address without Offset Address with Offset Description Holding Register Representation Default Value Saved Access<br>1 = Write IP<br>5050 5051 Address Command 2 = Write Subnet 0 Yes WO<br>3 = Write IP & Subnet<br>5051 5052 IP_1 0-255 192 Yes WO<br>5052 5053 IP_2 0-255 168 Yes WO<br>Continued on page 6<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 5 of 15 18-Mar-25 Modbus TCP/IP Register Map WLB32 Industrial Pro PoE LED Light Product Manual **==> picture [500 x 122] intentionally omitted <==** **----- Start of picture text -----**<br> Continued from page 5<br>Address without Offset Address with Offset Description Holding Register Representation Default Value Saved Access<br>5053 5054 IP_3 0-255 0 Yes WO<br>5054 5055 IP_4 0-255 1 Yes WO<br>5055 5056 Subnet_1 0-255 255 Yes WO<br>5056 5057 Subnet_2 0-255 255 Yes WO<br>5057 5058 Subnet_3 0-255 255 Yes WO<br>5058 5059 Subnet_4 0-255 0 Yes WO<br>**----- End of picture text -----**<br> ## Holding Registers for Device Identification **==> picture [500 x 55] intentionally omitted <==** **----- Start of picture text -----**<br> Address without Offset Address with Offset Description Holding Register Representation Default Value Saved Access<br>40606-40615 40607-40616 Banner Name Banner Engineering Yes RO<br>40617-40623 40618-40624 Product Name WLB32 Ethernet Yes RO<br>**----- End of picture text -----**<br> page 6 of 15 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 18-Mar-25 WLB32 Industrial Pro PoE LED Light Product Manual ## Chapter Contents FCC Part 15 Class B for Unintentional Radiators ................................................................................................................................................ 8 Industry Canada ICES-003(B).............................................................................................................................................................................. 8 Dimensions........................................................................................................................................................................................................... 8 Light Characteristics............................................................................................................................................................................................. 9 ## Chapter 4 ## Specifications Supply Voltage 42.5 V DC to 57 V DC Supply Protection Circuitry Protected against reverse polarity and transient voltages Light Characteristics Color: Daylight white Color temperature (CCT): 5000K (±300K) Lumen output: 750 (±5%) per foot, typical at 25 °C (77 °F) CRI: 80, minimum Spacing Criterion Vertical: 1.22 Horizontal: 1.32 Mounting Snap clips; optional magnetic mount or swivel bracket accessories available Connections - 475 mm (18.7 in) PVC-jacketed cable with a 4-pin D-Code M12 female quick-disconnect connector (4-pin connecting cordset required) - Integral 4-pin M12 female quick-disconnect connector (see Application Note) Environmental Rating IP40 ## LED Lifetime Lumen Maintenance - L70 When operating within specifications, output will decrease less than 30% after 70,000 hours. ## Construction Anodized aluminum housing; polycarbonate window and end caps; stainless steel mounting brackets ## Vibration and Mechanical Shock Vibration 10-55 Hz 1.0 mm p-p amplitude per IEC60068-2-6 Shock 15G 11 ms duration, half sine wave per IEC60068-2-27 ## Operating Temperature –40 °C to +50 °C (–40 °F to +122 °F) Storage Temperature –40 °C to +70 °C (–40 °F to +158 °F) ## Test Data ## Supply Current **==> picture [214 x 95] intentionally omitted <==** **----- Start of picture text -----**<br> |||||||| |---|---|---|---|---|---|---| |Lighted|Typical Current (A)|Max|Max|Power over| |Length|42.5|50 V|57 V|Current|Wattage|Ethernet| |(mm)|V DC|DC|DC|(A)|(W)|Specification| |285|0.155|0.14|0.13|0.17|7.25|PoE (Class 0 -| |802.3af,| |570|0.29|0.245|0.23|0.305|12.95|802.3at Type 1)| |850|0.445|0.375|0.34|0.455|19.45|PoE+ (Class 4| |- 802.3at Type| |1130|0.58|0.485|0.44|0.59|25|2)| **----- End of picture text -----**<br> Application Note To reset the IP address to 192.168.0.1, perform the following steps: 1. Plug the light into an ethernet switch and wait for the light to illuminate. 2. Remove the cap on the integral 4-pin M12 female quick-disconnect connector. 3. Attach a 4-pin M12 male cordset to the female connector, momentarily connect the brown wire (Pin 1) to the blue wire (Pin 3), and then remove the male cordset. 4. Unplug the light from the ethernet switch, and then plug it back into the switch to finish resetting the light. Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. LM-79, LM-80, TM-21 **==> picture [208 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> ||||| |---|---|---|---| |Supply|Supply| |Required Overcurrent|Required Overcurrent| |Wiring|Wiring| |Protection (A)|Protection (A)| |(AWG)|(AWG)| |20|5.0|26|1.0| |22|3.0|28|0.8| |24|1.0|30|0.5| **----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 7 of 15 18-Mar-25 Specifications WLB32 Industrial Pro PoE LED Light Product Manual ## Certifications Turck Banner LTD Blenheim House | Blenheim Court | Wickford, Essex SS11 8YT | Great Britain Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM **==> picture [26 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> E476617<br>**----- End of picture text -----**<br> ## FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. ## Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. ## Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. **==> picture [17 x 37] intentionally omitted <==** **----- Start of picture text -----**<br> L1<br>L2<br>**----- End of picture text -----**<br> Models L1 L2 WLB32PEXW285..QP 298 mm (11.7 in) 313 mm (12.3 in) WLB32PEXW570..QP 580 mm (22.8 in) 595 mm (23.4 in) WLB32PEXW850..QP 862 mm (33.9 in) 877 mm (34.6 in) WLB32PEXW1130..QP 1144 mm (45.0 in) 1159 mm (45.7 in) page 8 of 15 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 18-Mar-25 Specifications WLB32 Industrial Pro PoE LED Light Product Manual ## Light Characteristics **==> picture [90 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Illuminance at a Distance<br>**----- End of picture text -----**<br> **==> picture [59 x 20] intentionally omitted <==** **----- Start of picture text -----**<br> 285 mm Models<br>Isolux Pattern<br>**----- End of picture text -----**<br> Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 230 170°160°150°<br>0.17 m0.33 m 3682 lux1979 lux 0.4 m0.8 m 0.7 m1.4 m 1 192153115 LTTHye, 140°130°120°<br>0.50 m 825 lux 1.2 m 2.1 m 77 110°<br>0.67 m 439 lux 1.6 m 2.8 m 38 100°<br>0.83 m 345 lux 2.0 m 3.5 m 0 m 0 90°<br>223 lux 2.4 m 4.2 m 38 80°<br>1.00 m of oN<br>Vert. Horiz. 77 70°<br>== 115 [VR 60°<br>Vertical Spread: 101.5° 1 153 50°<br>Horizontal Spread: 128.8° 192 40°<br>230 Vertical Angle: 0° 10° 20° 30°<br>2<br>Mount height of 1 meter (1 m) oOo 0° Vertical ni 90° Horizontal<br>150 lux |_| 75 lux |_| 10 lux<br>125 lux |_| 50 lux |_| 5 lux<br>100 lux 25 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> **==> picture [469 x 187] intentionally omitted <==** **----- Start of picture text -----**<br> 570 mm Models<br>Illuminance at a Distance Isolux Pattern Polar Candela Distribution<br>2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 460 170°160°150°<br>4721 lux 0.4 m 0.7 m 383 LTT 140°<br>0.17 m0.33 m 2937 lux 0.8 m 1.4 m 1 307230 > 130°120°<br>0.50 m 1359 lux 1.2 m 2.1 m 153 eS? 110°<br>0.67 m 785 lux 1.6 m 2.7 m 77 eee 100°<br>0.83 m 621 lux 2.0 m 3.4 m 0 m 0 90°<br>1.00 m 4EESSSSEEE 451 lux 2.4 mVert. 4.1 mHoriz. 15377 WN 70°80°<br>7N“ Vertical Spread: 101.5°Horizontal Spread: 128.2° Tr 1 230307383 LNRY 40°50°60°<br>460 Vertical Angle: Me 0° 10° 20° 30°<br>2<br>Mount height of 1 meter (1 m) oO 0° Vertical ni 90° Horizontal<br>300 lux |_| 150 lux |_| 25 lux<br>250 lux |_| 100 lux |_| 10 lux<br>200 lux 50 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> **==> picture [59 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 850 mm Models<br>**----- End of picture text -----**<br> Polar Candela Distribution **==> picture [469 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> Illuminance at a Distance Isolux Pattern Polar Candela Distribution<br>2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 650 170°160°150°<br>5371 lux 0.4 m 0.7 m 542 140°<br>0.17 m0.33 m 3470 lux 0.8 m 1.4 m 1 433325 LTTHye’, 130°120°<br>0.50 m 1831 lux 1.3 m 2.1 m 217 Wien 110°<br>0.67 m 1103 lux 1.7 m 2.9 m 108 100°<br>0.83 m 899 lux 2.1 m 3.6 m 0 m 0 90°<br>1.00 m —i 647 lux a 2.5 mVert. 4.3 mHoriz. 108217 SfpareeeNETcoaae 70°80°<br>rN Vertical Spread: 102.7° —= 1 325433 (Ne 50°60°<br>A Horizontal Spread: 130.1° 542 RY 40°<br>650 Vertical Angle: ey 0° 10° 20° oe 30°<br>2<br>Mount height of 1 meter (1 m) Oo 0° Vertical ni 90° Horizontal<br>450 lux | 225 lux | 25 lux<br>375 lux |_| 150 lux |_| 10 lux Illuminance at a Distance<br>300 lux 75 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 9 of 15 18-Mar-25 Specifications WLB32 Industrial Pro PoE LED Light Product Manual ## 1130 mm Models ## Illuminance at a Distance Isolux Pattern Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 870 170°160°150°<br>5371 lux 0.4 m 0.7 m 725 140°<br>0.17 m0.33 m 3639 lux 0.8 m 1.4 m 1 580435 TLS 130°120°<br>0.50 m 2008 lux 1.3 m 2.1 m 290 LIKyee 110°<br>0.67 m 1274 lux 1.7 m 2.9 m 145 100°<br>0.83 m 1065 lux 2.1 m 3.6 m 0 m 0 90°<br>1.00 m 869 lux 2.5 m 4.3 m 145 80°<br>Vert. Horiz. 290 70°<br>Vertical Spread: 103.3° 1 435580 50°60°<br>Horizontal Spread: 129.7° 725 40°<br>870 Vertical Angle: 0° 10° 20° 30°<br>2 Mount height of 1 meter (1 m) im 0° Vertical ni 90° Horizontal<br>600 lux 7| 300 lux 50 lux<br>500 lux | 200 lux - 25 lux<br>400 lux 100 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> **==> picture [90 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Illuminance at a Distance<br>**----- End of picture text -----**<br> 285 mm Models with Eye Shields Isolux Pattern Polar Candela Distribution **==> picture [469 x 375] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 250 170°160°150°<br>3654 lux 0.4 m 0.4 m 208 - 140°<br>0.17 m0.33 m 2024 lux 0.8 m 0.8 m 1 167125 130°120°<br>0.50 m 813 lux 1.2 m 1.3 m 83 110°<br>0.67 m = 442 lux 1.6 m = 1.7 m 42 ThEWie 100°<br>0.83 m1.00 m rh 345 lux250 lux 2.0 m2.3 m 2.1 m2.5 m 0 m 420 yy> Ty] 80°90°<br>_ Ex Vert. Horiz. 83 \Saae 70°<br>“ Vertical Spread: 98.7° —- 1 125167 PASS 50°60°<br>A Horizontal Spread: 102.8° 208 IS 40°<br>250 Vertical Angle: —_ 0° 10° wy 20° 30°<br>2<br>Mount height of 1 meter (1 m) oO 0° Vertical ni 90° Horizontal<br>150 lux 7 75 lux r] 10 lux<br>125 lux - 50 lux 7] 5 lux<br>100 lux 25 lux<br>570 mm Models with Eye Shields<br>Illuminance at a Distance Isolux Pattern Polar Candela Distribution<br>2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 500 7 170°160°150°<br>5334 lux 0.3 m 0.4 m 417 + 140°<br>0.17 m0.33 m 3313 lux 0.6 m 0.8 m 1 333250 130°120°<br>0.50 m 1595 lux 0.9 m 1.1 m 167 TS 110°<br>0.67 m —_— 884 lux 1.2 m 1.5 m 83 BD 100°<br>0.83 m 706 lux 1.5 m 1.9 m 0 m 0 90°<br>1.00 m SS 484 lux 1.8 m 2.3 m 83 a Se 80°<br>EE, Vert. Horiz. 167 :TF SKROT 70°<br>~ Vertical Spread: 83.5° 1 250333 50°60°<br>Horizontal Spread: 97.0° 417 40°<br>A == 500 Vertical Angle: [\& 0° 10° 20° 30°<br>2<br>Mount height of 1 meter (1 m) im 0° Vertical ni 90° Horizontal<br>300 lux 7 150 lux | 25 lux<br>250 lux 100 lux 10 lux<br>“7 -]<br>200 lux 50 lux<br>CD<br>(candela)<br>CD<br>(candela)<br>**----- End of picture text -----**<br> page 10 of 15 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com 18-Mar-25 Specifications WLB32 Industrial Pro PoE LED Light Product Manual Illuminance at a Distance 850 mm Models with Eye Shields Isolux Pattern Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 630 170°160°150°<br>5533 lux 0.3 m 0.5 m 525 140°<br>0.17 m0.33 m 3460 lux 0.6 m 1.0 m 1 420315 130°120°<br>0.50 m 1815 lux 0.9 m 1.6 m 210 Wiese 110°<br>0.67 m 1096 lux 1.2 m 2.1 m 105 100°<br>0.83 m 896 lux 1.4 m 2.6 m 0 m 0 90°<br>1.00 m 623 lux 1.7 m 3.1 m 105 80°<br>Vert. Horiz. 210 70°<br>_,oe Vertical Spread: 81.4° oe 1 315420 2 +f | aan\\ wa L 50° 7 60° |<br>A Horizontal Spread: 114.2° 525 40°<br>630 Vertical Angle: 0° 10° 20° 30°<br>2<br>Mount height of 1 meter (1 m) 0° Vertical rH 90° Horizontal<br>450 lux a| 225 lux 25 lux<br>375 lux a 150 lux a 10 lux<br>300 lux 75 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> Illuminance at a Distance 1130 mm Models with Eye Shields Isolux Pattern Polar Candela Distribution **==> picture [469 x 163] intentionally omitted <==** **----- Start of picture text -----**<br> 2 1 0 m 1 2<br>2<br>180°<br>Center Beam (lux) Beam Width (m) 820 170°160°150°<br>5733 lux 0.3 m 0.6 m 683 + 140°<br>0.17 m0.33 m 3904 lux 0.6 m 1.3 m 1 547410 THO 130°120°<br>0.50 m 2203 lux 0.9 m 1.9 m 273 110°<br>0.67 m 1390 lux 1.2 m 2.6 m 137 | Ines| 100°<br>0.83 m 1139 lux 1.5 m 3.2 m 0 m 0 90°<br>1.00 m 806 lux 1.8 m 3.8 m 137 80°<br>Vert. Horiz. 273 70°<br>Vertical Spread: 83.8° 1 410547 50°60°<br>‘ Horizontal Spread: 124.8° 683 ear ee 40°<br>; 820 Vertical Angle: ET 0° 10° ee 20° 30°<br>2<br>Mount height of 1 meter (1 m) o 0° Vertical i 90° Horizontal<br>600 lux a 300 lux | 50 lux<br>500 lux a 200 lux a 25 lux<br>400 lux 100 lux<br>CD<br>(candela)<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 11 of 15 18-Mar-25 WLB32 Industrial Pro PoE LED Light Product Manual ## Chapter Contents Cordsets ............................................................................................................................................................................................................. 12 Mounting Brackets.............................................................................................................................................................................................. 12 ## Chapter 5 Accessories ## Cordsets **==> picture [480 x 278] intentionally omitted <==** **----- Start of picture text -----**<br> Double-Ended 4-pin M12 Male D-code to 8-Pin RJ45 Male Shielded Ethernet Cordsets<br>Model Length Dimensions RJ45 Pinout (Male) M12 Pinout (Male)<br>STP-M12D-403 0.9 m (2.95 ft) Ø 6.2 mm<br>STP-M12D-406 1.83 m (6 ft)<br>RJ45 1 4<br>STP-M12D-415 4.57 m (15 ft)<br>(<br>47.4 Typ. 2 3<br>1 = White/Orange 1 = White/Orange<br>STP-M12D-430 9.14 m (30 ft) 2 = Orange 2 = White/Blue<br>3 = White/Blue 3 = Orange<br>M12 x 1.0 6 = Blue 4 = Blue<br>ø 14.5<br>4-Pin D-Code Double-Ended M12 Male to M12 Male Shielded Cordset<br>Model Length "L1" Style Pinout<br>M12D-M12D-4M 4 m (13.1 ft) Male Straight / Male Straight<br>“L1”<br>1 4<br>1 = White / Orange<br>2 = White / Blue<br>3 = Orange<br>2 3 4 = Blue<br>Ø 6.2<br>**----- End of picture text -----**<br> ## Mounting Brackets ## LMBWLB32 - Replaces the bracket that ships with the WLB32 light - • Stainless steel • Includes 4 snap clips, 4 screws, and 2 insulator caps **==> picture [70 x 52] intentionally omitted <==** **----- Start of picture text -----**<br> 20 12<br>36<br>2X Ø6.5<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 12 of 15 18-Mar-25 WLB32 Industrial Pro PoE LED Light Product Manual Accessories **==> picture [500 x 86] intentionally omitted <==** **----- Start of picture text -----**<br> 42 20<br>LMBWLB32-180S<br>• Swivel bracket kit allows 180° of movement<br>36<br>Ø6.4<br>**----- End of picture text -----**<br> ## LMBWLB32MAG - Magnetic mounting bracket for easy attachment to steel and iron surfaces ## LMBWLB32U - Die-cast bracket for rugged applications - • Secured to light with included thumb screw • Clearance hole for 6 mm (1/4 in) button head screw - LMBWLB32UT • Die-cast bracket for rugged applications • Secured to light with included thumb screw • Integral 1/4-20 stud for mounting **==> picture [72 x 253] intentionally omitted <==** **----- Start of picture text -----**<br> 20 19<br>36<br>Ø36<br>41<br>18<br>20<br>41<br>18<br>20<br>27<br>**----- End of picture text -----**<br> © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 13 of 15 18-Mar-25 WLB32 Industrial Pro PoE LED Light Product Manual ## Chapter Contents Clean with Mild Detergent and Water................................................................................................................................................................. 14 Repairs ............................................................................................................................................................................................................... 14 Contact Us.......................................................................................................................................................................................................... 14 Banner Engineering Corp Limited Warranty....................................................................................................................................................... 14 Mexican Importer................................................................................................................................................................................................ 14 ## Chapter 6 Product Support and Maintenance ## Clean with Mild Detergent and Water Wipe down the device with a soft cloth that has been dampened with a mild detergent and warm water solution. ## Repairs Contact Banner Engineering for troubleshooting of this device. Do not attempt any repairs to this Banner device; it contains no field-replaceable parts or components. If the device, device part, or device component is determined to be defective by a Banner Applications Engineer, they will advise you of Banner's RMA (Return Merchandise Authorization) procedure. IMPORTANT: If instructed to return the device, pack it with care. Damage that occurs in return shipping is not covered by warranty. ## Contact Us Banner Engineering Corp. headquarters is located at: 9714 Tenth Avenue North | Plymouth, MN 55441, USA | Phone: + 1 888 373 6767 For worldwide locations and local representatives, visit www.bannerengineering.com. ## Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. ## Mexican Importer Banner Engineering de Mèxico, S. de R.L. de C.V. | David Alfaro Siqueiros 103 Piso 2 Valle oriente | San Pedro Garza Garcia Nuevo Leòn, C. P. 66269 81 8363.2714 © Banner Engineering Corp. All rights reserved. www.bannerengineering.com page 14 of 15 18-Mar-25 ## LinkedIn ## X (formerly Twitter) ## Facebook © 2025. All rights reserved. www.bannerengineering.com
Updated at April 28, 2026
Founded in 1966, Banner Engineering is a globally recognized leader in the design and manufacture of industrial automation products. The company is renowned for developing innovative, high-quality solutions that improve operational efficiency, safeguard personnel, and optimize manufacturing processes across a diverse range of industries. Our extensive selection of Banner Engineering components prominently features their industry-leading sensing technologies. We offer a comprehensive array of precision light sensors engineered for accurate detection and measurement in demanding environments. Complementing this core sensing portfolio is a robust offering of automation signaling devices, including visual signal indicator units and essential accessories, which provide clear and immediate communication of machine status. Beyond primary sensing and indication solutions, our range encompasses critical components for broader process control and machine safety. This includes advanced process controllers, reliable pressure sensors and transducers, and dependable safety relays. Supported by a variety of purpose-built sensor accessories and fiber optic lead assemblies, Banner Engineering delivers the durable, high-performance technologies required to build and maintain sophisticated automated systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →