W91-X152-50
CIRCUIT BREAKER, HYDROMAGNETIC, 1P, 65V, 50A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TE CONNECTIVITY - POTTER&BRUMFIELD
- Product type: Magnetic Hydraulic Circuit Breakers
- Product Range:W9 Series; Current Rating:50A; No. of Poles:1 Pole; Input Voltage VAC:-; Interrupting Capacity:2kA; Trip Time:20s; Dielectric Strength:1.1kV 13F3626
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 61.61 € |
| Current stock | 10+ |
| Lead time | 30 days |
General Purpose Relays Industrial Relays **Potter & Brumfield** ## **W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers** > n **Designed for the international market. UL Recognzied (UL1077 and UL1500), CSA Accepted and VDE approved.** > n **Ratings to 50 amps.** > n **Heavy duty #10-32 stud connections. (W9)** > n **Quick-connect or screw terminals. (W6)** > n **Several delay curve options.** > n **Choice of toggle or rocker actuator per pole or per unit (W6).** > n **Trip-free operation.** ## ~~**Agency Approvals**~~ **UL:** Recognized as Supplementary Protector under UL 1077. Available models meet Ignition Protection requirements in accordance with UL1500. File E69543 **CSA:** Accepted as a Supplementary Protector. File LR15734. **VDE:** Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment) License No. 73782 Users should thoroughly review the technical data before selecting a product part number. It is recommended that users also seek out the pertinent approvals files of the agencies/ laboratories and review them to confirm the product meets the requirements for a given application. ## ~~**Electrical Data**~~ **Calibration:** Breakers will hold 100% of rated current. Breakers may trip between 101% and 124% of rated load (134% for AC/ DC units). ## ~~**Mechanical/Environmental Data** (continued)~~ ## **Fungus and Moisture Resistance:** Special moisture resistant finish applied to all ferrous parts. Plastic parts are made of inherently fungus resistant material. **Marking:** International “1” and “0” symbols are marked on the toggle for both W6 and W9. W9 units have “ON” and “OFF” molded into the area at the base of the toggle. On a special order basis, graphics can be imprinted on the rockers of rocker actuated W6 units. VDE approved versions of rocker actuated W6 breakers have their rockers imprinted with “1” and “0”. **Mounting:** Units are mounted with two #6-32 screws from the front of the panel. Metric models for use with M3 x 0.5 screws are available. To maintain published performance specifications, units should not be mounted more than 90° from their normal upright position. **Weight:** Approximately 2.5 ounces per pole. Breakers must trip at 125% of rated load and above (135% for AC/DC units). **Dielectric Strength:** 50/60 Hz., 1500V: DC, 1100V **Insulation Resistance:** 100 Megaohms at 500VDC ## **Endurance:** 10,000 on/off cycles - 6000 at rated load, 4000 at no load. Units tested at six cycles per minute, 1 second on and 9 seconds off at 25°C ambient. |**Typical Resistance and Impedance**|**Typical Resistance and Impedance**|| |---|---|---| |Current DC|Current DC|50/60| |(Amps.)|(Amps.)<br>Resistance|Impedance| |(Ohms)|(Ohms)|(Ohms)| |0.2 90 90<br>1.0 1.2<br>2.0 0.28|0.2 90 90<br>1.0 1.2<br>2.0 0.28|0.2 90 90<br>1.2<br>0.28| |5.0 0.04<br>10.0 0.013<br>20.0 0.004<br>30.0 0.0027|5.0 0.04<br>10.0 0.013<br>20.0 0.004<br>30.0 0.0027|0.04<br>0.013<br>0.005<br>0.004| |40.0 0.002<br>50.0 0.0015|40.0 0.002<br>50.0 0.0015|0.002<br>0.0015| Tolerance: 0.1 - 4.99 ± 15%; 5 - 9.99 ± 20%; 10 - 15 ± 25%; 16 - 30 ± 50%. ## ~~**Mechanical/Environmental Data**~~ **Operating Temperature:** -40°C to +85°C. **Humidity:** Meets requirements of Mil-STD-202 method 103. **Shock:** Tested per Mil-STD-202, method 213, test condition C ## ~~**Approvals and Ratings Table 1**~~ |**Maximum**<br>**Voltage**|**Frequency**<br>**(Hz)**|**Phase**|**Current**<br>**Rating**<br>**(Amps)**|**Interrupting**<br>**Capacity**<br>**(Amps)**| |---|---|---|---|---| |65<br>277<br>277<br>277/480|DC<br>50/60<br>50/60<br>50/60|-<br>1<br>1<br>3Ø-Wye|0.2 - 50<br>0.2 - 20<br>21 - 50<br>0.2 - 20|2,000<br>5,000<br>2,500<br>5,000| |**Maximum**<br>**Voltage**|**Frequency**<br>**(Hz)**|**Phase**|**Current**<br>**Rating**<br>**(Amps)**|**Interrupting**<br>**Capacity**<br>**(Amps)**| |---|---|---|---|---| |65<br>277<br>277/480|DC<br>50/60<br>50/60|-<br>1<br>3Ø-Wye|0.2 - 50<br>0.2 - 50<br>0.2 - 20|2,000<br>5,000<br>5,000| |**Maximum**<br>**Voltage**|**Frequency**<br>**(Hz)**|**Phase**|**Current**<br>**Rating**<br>**(Amps)**|**Interrupting**<br>**Capacity**<br>**(Amps)**| |---|---|---|---|---| |65<br>250<br>250<br>415/240|DC<br>50/60<br>50/60<br>50/60|-<br>1<br>1<br>3Ø|0.2 - 50<br>0.2 - 30<br>31 - 50<br>0.2 -30|2,000<br>5,000<br>2,000<br>5,000| (100g @ 6 ms) |**Vibration:**Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06”<br>(1.52mm) total excursion in 2 planes.|Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06”<br>(1.52mm) total excursion in 2 planes.|**W6 or W9 Series**|**W6 or W9 Series**|**W6 or W9 Series**|**W6 or W9 Series**<br>**UL1500**|**W6 or W9 Series**<br>**UL1500**|**UL1500(Circuit Function X**|**Circuit Function X)**|**Circuit Function X)**|| |---|---|---|---|---|---|---|---|---|---|---| ||||**Maximum**<br>**Voltage**|**Frequency**<br>**(Hz)**|||**Phase**||**Current**<br>**Rating**<br>**(Amps)**|**Interrupting**<br>**Capacity**<br>**(Amps)**| ||||48||DC||-||0.2 - 50|3,000| ||||125/250||50/60||1||0.2 - 50|1,000| ||||250||50/60||3Ø-Wye||0.2 -50|1,000| 1 Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ secterms of the disclaimer and all chapters of tion, application notes and all specifications the ‘Definitions’ section, available at are subject to change. http://relays.te.com/definitions 12-2014, Rev. 1214 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company General Purpose Relays Industrial Relays **W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers** (Continued) **Potter & Brumfield** ## **Time vs Current Trip Curves For W6 Series and W9 Series** ## **AC 50/60 Hz.** **==> picture [520 x 533] intentionally omitted <==** **----- Start of picture text -----**<br> DC & 50/60 Hz.<br>10,000400 Hz. Ah CURVE 0 INSTANTANEOUSTRIP TIMES 10,000 CURVE 2 STANDARD DELAY 50/60 Hz. 10,000 a CURVE 3 SHORT DELAY 50/60 Hz. OVERLOAD TRIP TIMES<br>1000100101 E a a$=|HabaO—ae1 OVERLOAD @ 50/60 Hz. & DC @ 400 Hz. 800% 12 ms max. 600% 12 ms max. 150% 55 ms max. 125% 100 ms max. May Trip 400% 15 ms max. 200% 30 ms max. 30 ms max.100 ms max.12 ms max.12 ms max.15 ms max. 1000100101 __— + —aSSLN=SS —— | OVERLOAD TRIP TIMES (SEC.) 125% 10 - 150 200% 2.2 - 20 400% .2 - 2 600% .03 - .75 800% .007 - .151000% .005 - .04 | «| 1000100101 SSSSa——=(NI ————| (SEC.) 600% .007 - .15 400% .03 - .25 125% 1 - 15 200% .15 - 1.5 800% .003 - .081000% .003 - .04<br>.001.01.10 100 125 ee|—SSa 150200 300 400 500 600 700 800 900 1000 1100 1200 ——————SS LOAD CURRENT AS A PERCENTOF BREAKER RATING SS a SSes es eeea | .001.01.10 _—=Seea| 125 100 ee 150200 300 400 500 600 700 800 900 1000 1100 1200 ===—————E—————————————ee LOAD CURRENT AS A PERCENTOF BREAKER RATING ee—___ ee===ee eeeee .001.01.10 eeSSEcOe 125 100 ees 150200 300 400 500 600 700 800 900 1000 1100 1200 a a LOAD CURRENT AS A PERCENT a OF BREAKER RATING Sea aee<br>MOTOR START / LONG DELAY CURVE 12 HIGH INRUSH 50/60 Hz. CURVE 13 HIGH INRUSH 50/60 Hz.<br>10,0001000100101 SSSSSS=aSs==REAL<== CURVE 10 HIGH INRUSH 50/60 Hz. AC eea a aa ee (SEC.)OVERLOAD TRIP TIMES 200% 9 - 100 400% 2 - 20 600% .8 - 10 800% .1 - 4.51000% .009 - 2 | 125% 40 - 500 ee 10,0001000100101 SSSS ee —_—|—SS | ee=———— OVERLOAD TRIP TIMES 125% 10 - 150 200% 3 - 25 400% .5 - 2.5 600% .15 - 1 800% .015 - .71000% .009 - .35 (SEC.) 10,0001000100101 E—SS[T_=—oeNfSSS--_—=S=_|,+ —_] OVERLOAD TRIP TIMES (SEC.) 125% .8 - 30 200% .15 - 2.5 800% .009 - .12 400% .03 - .3 600% .02 - .151000% .009 - .09 | |<br>.01.1 — Sn=-=====—==>———————————————SO .01.1 a——SSSSS SE .01.1 esSSEeSSSSSaSS SSSa SSSee SSSee ee<br>.0010 _—Sc 125 100 150200 300 400 500 600 700 800 900 1000 1100 1200 SSF LOAD CURRENT AS A PERCENTOF BREAKER RATING a .0010 aee 125 150100 200 300 400 500 600 700 800 900 1000 1100 1200LOAD CURRENT AS A PERCENTOF BREAKER RATING a eea .0010 SSeea 125 150100 200 300 400 500 600 700 800 900 1000 1100 1200 oe er LOAD CURRENT AS A PERCENTOF BREAKER RATING<br>DC<br>10,000100010010 _—SS j| ——— CURVE 2 STANDARD DELAY DC ___C OVERLOAD TRIP TIMES (SEC.) 125% 2 - 55 200% .60 - 8 400% .1 - 1.5 600% .02 - .5 800% .004 - .05 10,000100010010 _—S—j-—————|SS—eeS | E——_—_—_—_——_—SSSSee CURVE 3 SHORT DELAY DC SSeSes|oes OVERLOAD TRIP TIMES (SEC.) 125% .6 - 7 200% .16 - 1.5 400% .03 - .25 600% .01 - .13 800% .004 - .05 | 10,000100010010 _a. e ——===—=He e ——— CURVE 53 DC HIGH INRUSH eeeeee OVERLOAD TRIP TIMES (SEC.) 200% 15 - 150 125% 80 - 700 400% 2 - 20 600% .70 - 10 800% .10 - 31000% .01 - .1 ee ee<br>1 SS a ——————— | 1000% .004 - .025 1 -—ta_— S++ ++, 1000% .003 - .015 Cid 1 _——NSaSS<br>.1 —aee ee ee ee | .1 a— eeee .1 SS———————SSSS<br>.01 .01<br>.0010 ———— 125 100 150200 300 400 500 600 700 800 900 1000 1100 1200LOAD CURRENT AS A PERCENTOF BREAKER RATING .0010 _ 125 150100 200 300 400 500 600 700 800 900 1000 1100 1200LOAD CURRENT AS A PERCENTOF BREAKER RATING | .001.010 SSSa 125 150100 200 300 400 500 600 700 800 900 1000 1100 1200LOAD CURRENT AS A PERCENT<br>OF BREAKER RATING<br>AC/DC<br>CURVE 34 DC, 50/60 Hz. STANDARD DELAY<br>10,000<br>OVERLOAD TRIP TIMES<br>100010010 _——_—=eree— -=———— (SEC.) 135% 1 - 90 200% .60 - 20 400% .095 - 2 600% .02 - .95 800% .002 - .45 eee<br>= 1000% .002 - .09<br>1 —_— SS<br>——<br>.1 SSSaSoSSS|<br>.01 |<br>——|<br>.001<br>0 125 150100 200 300 400 500 600 700 800 900 1000 1100 1200LOAD CURRENT AS A PERCENT<br>135 OF BREAKER RATING<br>TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS<br>TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS<br>TIME IN SECONDS TIME IN SECONDS TIME IN SECONDS<br>TIME IN SECONDS<br>**----- End of picture text -----**<br> ## **Note:** For instantaneous curves for all voltages refer to Curve 0 instananeous under the AC 50/60 Hz. heading 2 Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ secterms of the disclaimer and all chapters of tion, application notes and all specifications the ‘Definitions’ section, available at are subject to change. http://relays.te.com/definitions 12-2014, Rev. 1214 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company General Purpose Relays Industrial Relays **Potter & Brumfield** ## **W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers** (Continued) |**Product code structure**Typical product code<br>**W**<br>**W6 Series**|**67-**|**X**|**2**|**Q**|**1**|**2-**|**20**| |---|---|---|---|---|---|---|---| |**Circuit Breaker Mounting**<br> **W**<br>#6-32 mounting threads<br> **M**<br>M3.0 x 0.5 mounting threads|||||||| |**Number of Poles**<br> **67**<br>Single Pole<br> **68**<br>Two Pole<br> **69**<br>Three Pole<br> **70**<br>Four Pole|||||||| |**Circuit Function (Only X is VDE approved)**<br> **X**<br>Series trip|||||||| |**Actuator**<br> **One actuator per pole**<br> **1**Black toggle**3**Black rocker**5**Red rocker**9**Red toggle<br> **2**White toggle**4**White rocker**6**Grey rocker<br> **One actuator per unit**<br> **7**Black toggle**8**White toggle**J**Black rocker|Red toggle||||||| |**Termination**<br> **Q**<br>.250“ QC (DIN 46 244) [30A Max. UL/CSA; 25A Max. VDE]<br> **S**<br>#8-32 screw [30A Max.]<br> **T**<br>#10-32 screw [50A Max.]<br> **U**<br>#8-32 screw, nickel plated, bent inward 30° [30A Max.]<br> **V**<br>#10-32 screw, nickel plated, bent inward 30° [30A Max.]<br> <br> **Notes:**<br> #10-32 termination must be used for**all**ratings of greater than 30 amps.<br>#10-32 termination must be specified for circuit function D, but relay trip pole will be equipped<br>with .250“ QC.|||||||| |**Maximum Line Voltage (see Table 1 for current ranges)**<br> **UL/CSA**<br>1 277VAC, 50/60 Hz.<br> **Types**<br>2 277/480VAC, 50/60 Hz. [20A Max.] (Requires insulating barriers,<br>see outline dimension drawing)<br> <br>5 65VDC<br> <br>7 AC/DC 277VAC, 50/60 Hz. or 65VDC<br>(Time delay curve 34 must be specified)<br> <br>8 AC/DC 120VAC, 120/240VAC, 48VDC<br>(Agency Approval M [UL1500] and time delay curve 34 must be specified)<br> **VDE**<br>1 250VAC, 415/240VAC<br> **Types**<br>5 65VDC<br> <br>7 AC/DC 250VAC, 415/240VAC, 65VDC<br>(Time delay curve 34 must be specified)|||||||| |**Time Delay Curve**<br> **0**<br>Instantaneous**10**AC high inrush motor start / long delay<br> **2**<br>Standard delay**12**AC high inrush version of #2<br> **3**<br>Short delay**13**AC high inrush version of #3<br> **53**<br>DC high inrush**34**Combination AC/DC standard delay|||||||| |**Amp Rating**<br>0.2<br>0.50 1.0 2.0 3.0 4.0 6.0 7.5 9.0 11.0 15.0 25.0 35.0 45.0 Consult factory for<br>0.25 0.75 1.5 2.5 3.5 5.0 7.0 8.0 10.0 12.0 20.0 30.0 40.0 50.0 other values|||||||| |**Agency Approval**<br> **Blank**UL1077/CSA breaker<br> **V**<br>VDE approved breaker<br> **M**<br>UL1077/UL1500 ignition protected breaker|||||||| ## **Authorized distributors are more likely to stock the following items.** W67-X2Q10-3 W67-X2Q12-10 W67-X2Q13-3 W67-X2Q50-5 W67-X2Q52-30 W68-X2Q12-10 W68-X2Q110-10 W69-X2Q12-25 W67-X2Q10-5 W67-X2Q12-15 W67-X2Q13-10 W67-X2Q50-10 W67-X2Q110-15 W68-X2Q12-15 W68-X2Q110-20 W69-X2Q12-30 W67-X2Q12-2 W67-X2Q12-20 W67-X2Q13-15 W67-X2Q52-5 W67-X2Q110-20 W68-X2Q12-20 W69-X2Q12-5 W69-X2Q110-20 W67-X2Q12-3 W67-X2Q12-30 W67-X2Q13-20 W67-X2Q52-10 W68-X2Q12-3 W68-X2Q12-25 W69-X2Q12-10 W69-X2Q110-30 W67-X2Q12-5 W67-X2Q13-1 W67-X2Q13-25 W67-X2Q52-15 W68-X2Q12-5 W68-X2Q12-30 W69-X2Q12-15 W67-X2Q12-7 W67-X2Q13-2 W67-X2Q13-30 W67-X2Q52-20 W68-X2Q12-7 W68-X2Q13-15 W69-X2Q12-20 12-2014, Rev. 1214 Datasheets and product specification www.te.com according to IEC 61810-1 and to be used © 2014 Tyco Electronics Corporation, only together with the ‘Definitions’ section. a TE Connectivity Ltd. company Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 3 Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions General Purpose Relays Industrial Relays **Potter & Brumfield** ## **W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers** (Continued) **==> picture [444 x 399] intentionally omitted <==** **----- Start of picture text -----**<br> Product code structure Typical product code W 91- X 1 1 2- 20<br>W9 Series<br>Circuit Breaker Mounting<br>W #6-32 mounting threads<br> M M3.0 x 0.5 mounting threads<br>Number of Poles<br>91 Single Pole<br> 92 Two Pole<br>93 Three Pole<br> 94 Four Pole<br>Circuit Function (Only X is VDE approved)<br>X Series trip<br>Actuator<br>One actuator per pole<br>1 Black toggle<br>2 White toggle<br>Maximum Line Voltage (see Table 1 for current ranges)<br>UL/CSA 1 277VAC, 50/60 Hz.<br>Types 2 277/480VAC, 50/60 Hz. [20A Max.]<br>5 65VDC<br>7 AC/DC 277VAC, 50/60 Hz. or 65VDC<br> (Time delay curve 34 must be specified)<br>8 AC/DC 120VAC, 120/240VAC, 48VDC<br> (Agency Approval M [UL1500] and time delay curve 34 must be specified)<br>VDE 1 250VAC, 415/240VAC<br>Types 5 65VDC<br>7 AC/DC 250VAC, 415/240VAC, 65VDC<br> (Time delay curve 34 must be specified)<br>Time Delay Curve<br>0 Instantaneous 10 AC high inrush motor start / long delay<br>2 Standard delay 12 AC high inrush version of #2<br>3 Short delay 13 AC high inrush version of #3<br>53 DC high inrush 34 Combination AC/DC standard delay<br>Amp Rating<br> 0.20 0.75 2.0 3.5 6.0 8.0 11.0 20.0 35.0 50.0<br> 0.25 1.00 2.5 4.0 7.0 9.0 12.0 25.0 40.0 Consult factory for other values<br> 0.50 1.50 3.0 5.0 7.5 10.0 15.0 30.0 45.0<br>Agency Approval<br>Blank UL1077/CSA approved breaker<br>V VDE approved breaker<br>M UL1077/UL1500 ignition protected breaker<br>**----- End of picture text -----**<br> **Authorized distributors are more likely to stock the following items.** W91-X112-1 W91-X112-15 W91-X113-15 W91-X152-40 W92-X112-5 W92-X112-30 W92-X1110-30 W93-X112-30 W91-X112-2 W91-X112-20 W91-X150-5 W91-X152-50 W92-X112-7 W92-X112-40 W93-X112-5 W93-X112-40 W91-X112-3 W91-X112-40 W91-X152-10 W91-X1110-20 W92-X112-10 W92-X112-50 W93-X112-10 W93-X112-50 W91-X112-5 W91-X112-50 W91-X152-15 W92-X112-1 W92-X112-15 W92-X113-15 W93-X112-15 W93-X1110-20 W91-X112-7 W91-X113-5 W91-X152-20 W92-X112-2 W92-X112-20 W92-X113-20 W93-X112-20 W93-X1110-30 W91-X112-10 W91-X113-10 W91-X152-30 W92-X112-3 W92-X112-25 W92-X1110-20 W93-X112-25 4 Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 12-2014, Rev. 1214 www.te.com Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company General Purpose Relays Industrial Relays **Potter & Brumfield** ## **W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers** (Continued) ## **Outline Dimensions - Toggle Actuator Models** **==> picture [120 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> W6 Series<br>2.043 .66<br>.235 (51.89) 1.640 (16.8)<br>(5.97) (41.66) .245<br>(6.22)<br>ON<br>_<br>LINE A 29°<br>(38.61)1.520 30°<br>OFF<br>B<br>LOAD i.<br>**----- End of picture text -----**<br> **==> picture [124 x 94] intentionally omitted <==** **----- Start of picture text -----**<br> Panel Mounting Cutout<br>.750<br> -.000Ø .625 +.010 (19.05)<br>(15.88 +0.25 -0.00 ) 6,<br> 1 PER POLE<br>1.660<br>(42.16)<br>1.048<br>(26.62)<br>Lip Ø .156(3.96) [[2 PLACES PER POLE]] eo<br>**----- End of picture text -----**<br> ## **W6 Series - One Actuator Per Pole** **==> picture [177 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> 1 Pole 2 Pole<br>Ø .590<br>(15.00) .750 1.500<br>a (19.05) — (38.10)<br>2.000 1.660<br>(50.80) (42.16)<br>1.05<br>1.22 (26.67)<br>(31.00)<br>in —<br>6.32 TH'D. .14 (3.56) DP. TYP.<br>M3 X 0.5 OPTIONAL<br>**----- End of picture text -----**<br> **==> picture [164 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 3 Pole 4 Pole<br>**----- End of picture text -----**<br> **==> picture [163 x 12] intentionally omitted <==** **----- Start of picture text -----**<br> 2.250 3.000<br>(57.15) ts (76.20)<br>**----- End of picture text -----**<br> **==> picture [190 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> Note: Multi-pole models furnished with seperate handle tie hardware<br>**----- End of picture text -----**<br> ## **W6 Series - One Actuator Per Unit** **==> picture [206 x 112] intentionally omitted <==** **----- Start of picture text -----**<br> 1 Pole 2 Pole<br>Ø .590<br>(15.00) .750<br>(19.05) 1.500<br>|alk- _——Fo (38.10) y e]—4<br>1.660<br>2.000 (42.16)<br>(50.80)<br>1.05<br>1.22 (26.67)<br>(31.00)<br>6.32 TH'D. .14 (3.56) DP. TYP.<br>M3 X 0.5 OPTIONAL<br>**----- End of picture text -----**<br> **==> picture [22 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 3 Pole<br>**----- End of picture text -----**<br> ## **4 Pole** **==> picture [220 x 104] intentionally omitted <==** **----- Start of picture text -----**<br> 2.250 3.000<br>(57.15) (76.20)<br>o u e) fo n e e h o)<br>Note: 4-pole models furnished with sperate<br> handle tie hardware<br>**----- End of picture text -----**<br> **480V Model with Barriers** **==> picture [475 x 173] intentionally omitted <==** **----- Start of picture text -----**<br> 2.250 2.778<br>(57.15) .269 (70.56)<br>(6.83)<br>dg) oe|<br>2.530<br>(64.26)<br>Termination Options<br>bien’ ) BO .266 Ler | LINE ns LINE LINE on<br>(6.76) A A A<br>Note: 3-pole model shown<br>1.520<br>Notes: (38.61)<br>1. Terminal protrusion dimensions are referenced from back of mounting panel<br>2. Main terminals are male quick connect type .250 (6.35) wide x .031 (.79) thick x B B B<br>.377 (9.58) long. Optional 8-32 x .250 (6.35) or 10-32 x .250 (6.35) screw type LOAD LOAD LOAD<br>3. Panel mounting cutout detail mtg. detail tol.: ± .005 (.13) unless noted. Add ± .005 (.13) unless noted. Add .005 (.13) unless noted. Add TI<br>**----- End of picture text -----**<br> 3. Panel mounting cutout detail mtg. detail tol.: ± .005 (.13) unless noted. Add ± .005 (.13) unless noted. Add .005 (.13) unless noted. Add additional cutouts to correspond to number of poles. Outline drawing tolerance ± .015 (.35) unless noted 5 Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 12-2014, Rev. 1214 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions General Purpose Relays Industrial Relays **Potter & Brumfield** ## **W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers** (Continued) ## **Outline Dimensions - Optional Toggle Guards** **==> picture [38 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> W6 Series<br>**----- End of picture text -----**<br> **==> picture [490 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> .625 INSIDE 1.375 INSIDE 2.185 INSIDE<br>.03 (15.88) (34.92) .313 1.093 (55.50)<br>(.76)(7.95).313 (19.05).75 (7.95) (27.76)(19.05).75 (19.05).75<br>.2 x<br>.47 R1.0<br>(2.03).08 | \ (24.1).95 (4.32).17 In. (11.94)(15.88).625 | ES .17 REF.(4.32)(25.4) 7 (19.8).78 |<br>2.00<br>(50.8) 1.66<br>(42.16)<br>2 x<br>.27 DIA. .44<br>(6.86) iom aer | _ (11.18) cai -<br>a (13.46).53 2 x .16 DIA.(4.06) oD 4 x .16 DIA.(4.06) 6 6 x .16 DIA. bP (4.06) Pp © TJ (5.08).20 . 84-004 toggle guard shown withW67 series circuit breaker<br>84-004 84-005 84-006 mounted in a panel.<br>( for 1 Pole ( for 2 Pole ( for 3 Pole<br>Breaker) Breaker) Breaker)<br>**----- End of picture text -----**<br> Optional toggle guards may be ordered seperately for use on W6 toggle actuator models. These guards help to prevent accidental operation and allow the breaker to be locked in the “off” position. ## **Outline Dimensions - Rocker Actuator Models** **==> picture [450 x 141] intentionally omitted <==** **----- Start of picture text -----**<br> 1 Pole<br>2, 3 & 4 Pole,<br>W6 Series (Shown with optional “ON”<br>One Actuator Per Pole<br>and “OFF” graphics)<br>3.000<br>(6.10).240 (44.93)1.769 (9.96).392 (19.65).774 (4.57).180 (9.53).375 (19.05).750 2 POLE(38.10)1.500 (57.15)2.250 (76.20)POLE3 POLE4<br>pj LOAD D qe Ea 4<br>.388<br>(38.61)1.520 (42.16)1.660 (50.80)2.000 ON (9.86)<br>| OFF 2.600<br>LINE A (33.0)1.30 | (66.04)<br>Th 2 fe<br>.375<br>M3 X 0.5 OPTIONALTAPPED FOR #6-32 (9.53) (19.05).750 .750 (19.05).750<br>2.435 (19.05)<br>(61.85)<br>**----- End of picture text -----**<br> **==> picture [131 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> Panel Mounting Cutout<br>.750 .750<br>.375 (19.05) .750 (19.05) .205<br>(9.53) (19.05) (5.21)<br>wit<br>O00 t<br>1.250<br>9 ial (31.75)<br>1.660<br>(42.16)<br>1 POLE .750<br>2 POLE3 POLE4 POLE (19.05) (38.10)1.500 (57.15)2.250 3.000 PER POLEØ .156TYP. 2(3.96)<br>ro) Le - (76.20) 7<br>**----- End of picture text -----**<br> **==> picture [323 x 243] intentionally omitted <==** **----- Start of picture text -----**<br> 2, 3 & 4 Pole, One Actuator Per Unit<br>1.500 2.250 3.000<br>(38.10) (57.15) (76.20)<br>.388 —<br>(9.86)<br>2.000 eM 1.660 — S ATS ]<br>(50.80) (42.16)<br>1.660 || | es ettel!<br>2.600 (42.16)<br>(66.04)<br>| c a hye | I | |<br>.375<br>(9.53)<br>(9.53).375 nu (19.05) s .750 j M3 X 0.5 OPTIONALTAPPED FOR #6-32 ( 2 (19.05).750 au (19.05) n .750 Of (9.53).375 Lo u (19.05).750 nl (19.05).750 (19.05).750 oe)<br>BO Ty<br>VDE Rocker Marking<br>Notes:<br>I<br>1. Outline drawing tolerance ± .015 (.38) unless noted.<br>O Dimensions in brackets ( ) are in milimeters.<br>2. Mounting Detail Tol. ± .005 (.013) unless noted<br>—<br>**----- End of picture text -----**<br> © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ secterms of the disclaimer and all chapters of tion, application notes and all specifications the ‘Definitions’ section, available at are subject to change. http://relays.te.com/definitions 6 12-2014, Rev. 1214 www.te.com General Purpose Relays Industrial Relays **Potter & Brumfield** ## **W6/W9 Series Magnetic Hydraulic P&B Circuit Breakers** (Continued) ## **Outline Dimensions** ## **W9 Series** **==> picture [146 x 172] intentionally omitted <==** **----- Start of picture text -----**<br> Series Trip Model<br>.060<br>(1.52) 1.845<br>.281 .375 (46.86) .313<br>(7.14) (9.52) 1.15 (7.95)<br>(29.21)<br>LINE ON<br>29°<br>1.940<br>(49.28) 30°<br>OFF<br>LOAD<br>#10-32<br>STUD .14<br>TERMINATION 2.10 (3.56)<br>(53.34)<br>2.50 .74<br>= (64.00) (18.8)<br>Note:<br>1. Top mounted plate (shown with broken line)<br>is present only on UL1500 models<br>**----- End of picture text -----**<br> ## **Series Trip Model** **==> picture [226 x 133] intentionally omitted <==** **----- Start of picture text -----**<br> .750 .375 .750 .750<br>(9.53).375 (19.05) (9.53) (19.05) (19.05).750 (19.05) (10.11).398<br>.060 ON ON ON ON ON ON ON ON ON ON<br>(1.52) .218<br>(5.54) 1.438<br>2.065 (36.53)<br>(52.45) 2.50<br>OFF OFF OFF OFF OFF OFF OFF O FF OFF OFF (63.5)<br>2 POLE<br>1 POLE 1.500<br>TAPPED #6-32 X .16 (4.06) (38.10) 2.250 3 POLE<br>DEEPM3 X 0.5 OPTIONAL a (57.15) (76.20)3.000 4 POLE<br>**----- End of picture text -----**<br> **==> picture [163 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Panel Mounting Cutout Detail<br>.750 .750<br>.732 (19.05) .750 (19.05) .385<br>(18.59) (19.05) (9.78)<br>t e<br>.907<br>(23.04)<br>1.450<br>(36.83) 2.065<br>enna (52.45)<br>2X Ø .156 .76 1 POLE<br>(3.96) 1.52 (19.3) 2 POLE<br>PER POLE ~ iakchs 2.28 (38.6) 4 3 POLE<br>3.04 (57.9) 4 POLE<br>(77.2)<br>**----- End of picture text -----**<br> **==> picture [23 x 5] intentionally omitted <==** **----- Start of picture text -----**<br> Notes:<br>**----- End of picture text -----**<br> 1. Terminal protrusion dimensions are referenced from the back of the mounting panel 2. Mounting detail tolerance ± .005 (13) unless noted 3. Outline drawing tolerance ± .015 (.38) unless noted Dimensions in brackets ( ) are in milimeters. **Disclaimer:** While TE and its affiliates referenced herein have made every reasonable effort to ensure the accuracy of the information contained in this document, TE cannot assure that this information is error free. For this reason, TE does not make any representation or offer any guarantee that such information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information at any time. TE expressly disclaims any implied warranty regarding the information contained herein, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose. TE‘s only obligations are those stated in TE’s Standard Terms and Conditions of Sale. TE will in no case be liable for any incidental, indirect or consequential damages arising from or in connection with, including, but not limited to, the sale, resale, use or misuse of its products. Users should rely on their own judgment to evaluate the suitability of a product for a certain purpose and test each product for its intended application. In case of any potential ambiguities or questions, please don’t hesitate to contact us for clarification. 7 Datasheets and product specification according to IEC 61810-1 and to be used only together with the ‘Definitions’ section. Datasheets, product data, ‘Definitions’ section, application notes and all specifications are subject to change. 12-2014, Rev. 1214 www.te.com © 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company Datasheets and product data is subject to the terms of the disclaimer and all chapters of the ‘Definitions’ section, available at http://relays.te.com/definitions
Updated at April 26, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →