AC/DC PCB Mount Power Supply (PSU), ITE, 1 Output, 3 W, 12 VDC, 250 mA
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CUI
- Product type: AC / DC PCB Mount Power Supplies
- SVHC: To Be Advised
- Depth: 23mm
- Width: 37mm
- Height: 15mm
- Product Range: VSK-S3 Series
- No. of Outputs: 1 Output
- Output Power Max: 3W
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 250mA
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 12VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 12.8 € |
| Current stock | 10+ |
| Lead time | 30 days |
Additional Resources: Product Page | 3D Model | PCB Footprint **date** 03/31/2014 **page** 1 of 5 ## **SERIES:** VSK-S3 **DESCRIPTION:** AC-DC POWER SUPPLY **│** ## **FEATURES** - up to 3 W continuous power - compact board mount design - universal input (85~264 Vac / 110~370 Vdc) - single output from 3.3~24 V - over voltage, over temperature, and short circuit protections - UL/cUL safety approvals - efficiency up to 78% |**MODEL**|**output**<br>**voltage**|**output**<br>**current**|**output**<br>**power**|**ripple**<br>**and noise1**|**efficiency**| |---|---|---|---|---|---| |||**max**|**max**|**typ**|**typ**| ||**(Vdc)**|**(A)**|**(W)**|**(mVp-p)**|**(%)**| |VSK-S3-3R3U|3.3|0.7|2.3|30|63| |VSK-S3-5U|5|0.6|3|30|72| |VSK-S3-9U|9|0.33|3|30|74| |VSK-S3-12U|12|0.25|3|30|76| |VSK-S3-15U|15|0.2|3|30|76| |VSK-S3-24U|24|0.125|3|30|78| Notes: 1. Ripple and noise measured at 20 MHz bandwidth ## **PART NUMBER KEY** ## **VSK-S3 - XXU** Base Number Output Voltage **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VSK-S3 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/31/2014 **│ page** 2 of 5 ## **INPUT** |**INPUT**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |voltage||85<br>110||264<br>370|Vac<br>Vdc| |frequency||47||440|Hz| |current|at 110 Vac<br>at 230 Vac||65<br>30||mA<br>mA| |inrush current|at 110 Vac<br>at 230 Vac||10<br>20||A<br>A| |external input fuse<br>(recommended)|slow blow, 250 V||0.5||A| |**OUTPUT**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |line regulation|||±0.5||%| |load regulation|10 ~ 100%||±1||%| |temperature coeffcient|||0.02||%/°C| |hold-up time|at 230 Vac||50||ms| |voltage accuracy|3.3 V model<br>all other models||±3<br>±2||%<br>%| |switching frequency|||100||kHz| |**PROTECTIONS**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |over voltage protection|chip lock up||||| |short circuit protection|auto recovery with no damage from a short on any output||||| |over temperature protection||||150|°C| |**SAFETY & COMPLIANCE**|||||| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |isolation voltage|primary to secondary (for 1 minute)|3,000|||Vac| |safety approvals|UL 60950-1||||| |safety class|class II||||| |EMI/EMC|EN 55022 (level A), IEC/EN 61000-4-2 (level 4, 8kV/15kV), IEC/EN<br>(level 3, 2kV), IEC/EN 61000-4-5 (level 3, 1kV/2kV)||61000-4-3,|IEC/EN|61000-4-4| |MTBF|25°C|300,000|||hrs| |RoHS|2011/65/EU||||| ## **ENVIRONMENTAL** |**ENVIRONMENTAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |operating temperature||-25||70|°C| |storage temperature||-40||105|°C| |case temperature||||95|°C| |operating humidity|non-condensing|||95|%| **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VSK-S3 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/31/2014 **│ page** 3 of 5 ## **DERATING CURVES** ## 1. output power vs. ambient temperature **==> picture [169 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>50<br>40<br>20<br>-40 -30 -25 -20 -10 0 10 50 60 70<br>Ambient Temperature (°C)<br>≈<br>Load (%)<br>≈<br>**----- End of picture text -----**<br> ## 2. output power vs. input voltage **==> picture [172 x 90] intentionally omitted <==** **----- Start of picture text -----**<br> 100<br>80<br>60<br>50<br>40<br>20<br> 70 85 110 125 210 225 240 264<br>Input Voltage (Vac)<br>≈<br>Load (%)<br>≈<br>**----- End of picture text -----**<br> ## **MECHANICAL** |**MECHANICAL**|||||| |---|---|---|---|---|---| |**parameter**|**conditions/description**|**min**|**typ**|**max**|**units**| |dimensions|1.457 x 0.908 x 0.591 (37.0 x 23.0 x 15.0 mm)||||inch| |case material|UL94V-0||||| |weight|||25||g| ## **MECHANICAL DRAWING** units: mm [inches] tolerance: ±0.5 [±0.02] pin section tolerance: ±0.10 [±0.004] ||| |---|---| |**PIN CONNECTIONS**|| |PIN|FUNCTION| |1|L| |3|N| |13|N/C| |14|0V| |16|+Vo| |22|+Vin(DC)| |26|-Vin(DC)| ||| **==> picture [513 x 287] intentionally omitted <==** **----- Start of picture text -----**<br> 37.00 1.457 1 L<br>3 N<br>13 N/C<br>14 0V<br>15.00 0.591<br>16 +Vo<br>22 +Vin(DC)<br>26 -Vin(DC)<br>4.10 0.161 0.80 0.031<br>(TYP) (7 PLCS)<br>3.26 0.128 2.61 0.103<br>8.34 0.328 (2 PLCS) (TYP) 2.54<br>1 3 13<br>1.2 0.047 26 22 16 14<br>(7 PLCS)<br>23.00 0.906 17.78 0.700<br>26 22 16 14<br>1 3 13<br>3.26 0.128 5.08 0.200<br>(2 PLCS) BOTTOM VIEW (TYP)<br>RECOMMENDED FOOTPRINT<br>13.42 0.528 TOP VIEW<br>**----- End of picture text -----**<br> **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VSK-S3 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/31/2014 **│ page** 4 of 5 ## **TYPICAL APPLICATION CIRCUIT** **==> picture [562 x 79] intentionally omitted <==** **----- Start of picture text -----**<br> * FUS E * NT C C 1 C 2 Tv s *F USE *NT C C1 C2 Tvs<br>L L +V0 L L +V0<br>C7<br>MOV + C 3 22 + R L C 6 NF MOV C3+ 22 + RL<br>26 C8 26<br>- V0<br>-V0<br>N N N N<br>Figure1<br>**----- End of picture text -----**<br> Figure 2 VSK-S3 EMC Filtering Circuit |||||| |---|---|---|---|---| |**EXTERNAL CAPACITORS TYPICAL VALUE(Unit:µF)**||||| |MODEL|C1|C2|C3|TVS| |VSK-S3-3R3U|150|0.1|4.7/400V|P4KE6.8A| |VSK-S3-5U|150|0.1|4.7/400V|P4KE6.8A| |VSK-S3-9U|150|0.1|4.7/400V|P4KE12A| |VSK-S3-12U|150|0.1|4.7/400V|P4KE20A| |VSK-S3-15U|150|0.1|4.7/400V|P4KE20A| |VSK-S3-24U|150|0.1|4.7/400V|P4KE30A| - Notes: 1. Output filtering capacitors C1, C3 is electrolytic capacitors, It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of apacitor should be 80% or above. C2, C4 is ceramic capacitors , it is used to filter high frequency noise. TVS is a recommended component to protect post-circuits (when converter fails). 2. MOV is required for VSK-S3 models. Model: 471KD05, it is used to protect the device under surge. 3. It is recommended to connect FUSE, the parameter is 0.5A/250V slow blow. External input NTC is recommended to use D -14 or 10Ω/2W wire-round resistor. 4. If EMC performance is required, recommended to add “EMC filter” at the input end(see figure 2) C6:X capacitor, recommended parameter 0.1uF/275V; C7,C8:Y capacitor, recommended parameter 220pF/275V; NF: common model choke, recommended inductance is about 10mH-30mH. 5. Terminals 22 and 26 are internal rectification and filtering terminals. To protect the models further, it is recommended to connect an electrolytic capacitor C3 (it is recommended to be 4.7uF/400V). If operation voltage of the module is between 160~264VAC, C3 can be removed. 1. All specifications measured at Ta=25°C, humidity <75%, rated input voltage, and rated output load, unless otherwise specified. Note: **cui** .com Additional Resources: Product Page | 3D Model | PCB Footprint **CUI Inc │ SERIES:** VSK-S3 **│ DESCRIPTION:** AC-DC POWER SUPPLY **date** 03/31/2014 **│ page** 5 of 5 ## **REVISION HISTORY** |**rev.**|**description**|**date**| |---|---|---| |1.0|initial release|02/27/2009| |1.01|new template applied|04/10/2012| |1.02|V-Infnitybrandingremoved|08/15/2012| |1.03|updated spec|03/31/2014| The revision history provided is for informational purposes only and is believed to be accurate. **Headquarters** 20050 SW 112th Ave. Tualatin, OR 97062 **800.275.4899** Fax 503.612.2383 **cui** .com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →